1
|
Fast Detection of 2,4,6-Trinitrotoluene (TNT) at ppt Level by a Laser-Induced Immunofluorometric Biosensor. BIOSENSORS-BASEL 2020; 10:bios10080089. [PMID: 32764236 PMCID: PMC7460505 DOI: 10.3390/bios10080089] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 07/27/2020] [Accepted: 07/30/2020] [Indexed: 12/20/2022]
Abstract
The illegal use of explosives by terrorists and other criminals is an increasing issue in public spaces, such as airports, railway stations, highways, sports venues, theaters, and other large buildings. Security in these environments can be achieved by different means, including the installation of scanners and other analytical devices to detect ultra-small traces of explosives in a very short time-frame to be able to take action as early as possible to prevent the detonation of such devices. Unfortunately, an ideal explosive detection system still does not exist, which means that a compromise is needed in practice. Most detection devices lack the extreme analytical sensitivity, which is nevertheless necessary due to the low vapor pressure of nearly all explosives. In addition, the rate of false positives needs to be virtually zero, which is also very difficult to achieve. Here we present an immunosensor system based on kinetic competition, which is known to be very fast and may even overcome affinity limitation, which impairs the performance of many traditional competitive assays. This immunosensor consists of a monolithic glass column with a vast excess of immobilized hapten, which traps the fluorescently labeled antibody as long as no explosive is present. In the case of the explosive 2,4,6-trinitrotoluene (TNT), some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and chip-based mixing-devices and flow-cells. The system achieved limits of detection of 1 pM (1 ppt) of the fluorescent label and around 100 pM (20 ppt) of TNT. The total assay time is less than 8 min. A cross-reactivity test with 5000 pM solutions showed no signal by pentaerythritol tetranitrate (PETN), 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). This immunosensor belongs to the most sensitive and fastest detectors for TNT with no significant cross-reactivity by non-related compounds. The consumption of the labeled antibody is surprisingly low: 1 mg of the reagent would be sufficient for more than one year of continuous biosensor operation.
Collapse
|
2
|
Modeling the transport and capture of analytes in a two-phase heterogeneous microfluidic immunosensor. Chem Eng Res Des 2019. [DOI: 10.1016/j.cherd.2018.11.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
3
|
Sanchis A, Salvador JP, Marco MP. Multiplexed immunochemical techniques for the detection of pollutants in aquatic environments. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.06.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
4
|
Vashist SK, Lam E, Hrapovic S, Male KB, Luong JHT. Immobilization of Antibodies and Enzymes on 3-Aminopropyltriethoxysilane-Functionalized Bioanalytical Platforms for Biosensors and Diagnostics. Chem Rev 2014; 114:11083-130. [DOI: 10.1021/cr5000943] [Citation(s) in RCA: 212] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Sandeep Kumar Vashist
- HSG-IMIT - Institut für Mikro- und Informationstechnik, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
- Laboratory for MEMS Applications, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Edmond Lam
- National Research Council Canada, Montreal, Quebec H4P 2R2, Canada
| | | | - Keith B. Male
- National Research Council Canada, Montreal, Quebec H4P 2R2, Canada
| | - John H. T. Luong
- Innovative Chromatography Group, Irish Separation Science Cluster (ISSC), Department of Chemistry and Analytical, Biological Chemistry Research Facility (ABCRF), University College Cork, Cork, Ireland
| |
Collapse
|
5
|
Microcapillary electrochemical droplet cells: applications in solid-state surface analysis. J Solid State Electrochem 2014. [DOI: 10.1007/s10008-014-2413-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
6
|
Zang J, Guo CX, Hu F, Yu L, Li CM. Electrochemical detection of ultratrace nitroaromatic explosives using ordered mesoporous carbon. Anal Chim Acta 2011; 683:187-91. [DOI: 10.1016/j.aca.2010.10.019] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2010] [Revised: 10/12/2010] [Accepted: 10/13/2010] [Indexed: 10/18/2022]
|
7
|
Liu F, Zhang LJ, Xiao JH, Hu J, Liu HL. A mesoporous silica modified conjugated polymer film: Preparation and detection nitroaromatics in aqueous phase. ACTA ACUST UNITED AC 2010. [DOI: 10.1007/s11706-010-0018-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
8
|
Fluorescence-based sensing of 2,4,6-trinitrotoluene (TNT) using a multi-channeled poly(methyl methacrylate) (PMMA) microimmunosensor. SENSORS 2010; 10:876-89. [PMID: 22315573 PMCID: PMC3270874 DOI: 10.3390/s100100876] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2009] [Revised: 01/15/2010] [Accepted: 01/19/2010] [Indexed: 11/18/2022]
Abstract
Fluorescence immunoassays employing monoclonal antibodies directed against the explosive 2,4,6-trinitrotoluene (TNT) were conducted in a multi-channel microimmunosensor. The multi-channel microimmunosensor was prepared in poly (methyl methacrylate) (PMMA) via hot embossing from a brass molding tool. The multi-channeled microfluidic device was sol-gel coated to generate a siloxane surface that provided a scaffold for antibody immobilization. AlexaFluor-cadaverine-trinitrobenzene (AlexaFluor-Cad-TNB) was used as the reporter molecule in a displacement immunoassay. The limit of detection was 1–10 ng/mL (ppb) with a linear dynamic range that covered three orders of magnitude. In addition, antibody crossreactivity was investigated using hexahydro-1,3,5-triazine (RDX), HMX, 2,4-dinitrotoluene (DNT), 4-nitrotoluene (4-NT) and 2-amino-4,6-DNT.
Collapse
|
9
|
Pittman TL, Thomson B, Miao W. Ultrasensitive detection of TNT in soil, water, using enhanced electrogenerated chemiluminescence. Anal Chim Acta 2009; 632:197-202. [DOI: 10.1016/j.aca.2008.11.032] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2008] [Revised: 08/26/2008] [Accepted: 11/10/2008] [Indexed: 11/30/2022]
|
10
|
Capillary waveguide fluoroimmunosensor with improved repeatability and detection sensitivity. Anal Bioanal Chem 2008; 393:1081-6. [DOI: 10.1007/s00216-008-2501-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2008] [Revised: 10/23/2008] [Accepted: 10/27/2008] [Indexed: 11/25/2022]
|
11
|
Mastichiadis C, Niotis A, Petrou P, Kakabakos S, Misiakos K. Capillary-based immunoassays, immunosensors and DNA sensors – steps towards integration and multi-analysis. Trends Analyt Chem 2008. [DOI: 10.1016/j.trac.2008.08.003] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
12
|
Meaney MS, McGuffin VL. Luminescence-based methods for sensing and detection of explosives. Anal Bioanal Chem 2008; 391:2557-76. [DOI: 10.1007/s00216-008-2194-6] [Citation(s) in RCA: 152] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2007] [Revised: 05/15/2008] [Accepted: 05/20/2008] [Indexed: 11/29/2022]
|
13
|
Hikal WM, Harmon HJ. Early events in 2,4,6-trinitrotoluene (TNT) degradation by porphyrins: binding of TNT to porphyrin by hydrophobic and hydrogen bonds. JOURNAL OF HAZARDOUS MATERIALS 2008; 154:826-831. [PMID: 18063299 DOI: 10.1016/j.jhazmat.2007.10.098] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2007] [Revised: 09/25/2007] [Accepted: 10/29/2007] [Indexed: 05/25/2023]
Abstract
The interaction of meso-tri(4-sulfonatophenyl)mono(4-carboxyphenyl) porphyrin (C1TPP) with 2,4,6-trinitrotoluene (TNT) has been explored by UV-vis and fluorescence spectroscopy. The influence of temperature on the interaction has also been studied. C1TPP binds to TNT at pH 7.0 at room temperature via 1.94 kcal/mole hydrogen bonds with absorbance loss at 412-413 nm and the appearance of a new peak at 422-424 nm. The hydrogen binding of TNT to C1TPP was confirmed by the dissolution of the complex upon the addition of urea. Increasing the temperature results in the appearance of a new absorbance peak at 540 nm and absorbance loss at 515 nm with activation energy of 29.7 kcal/mole in the range of the hydrophobic bond energy. This suggests the hydrophobic bonding of TNT with the pyrrole nitrogens in the porphyrin. Increasing the concentration of the TNT in the solution quenches the fluorescence of the porphyrin following the Stern-Volmer equation. The association constants calculated from absorbance and fluorescence are expectedly similar.
Collapse
Affiliation(s)
- Walid M Hikal
- Department of Physics, Oklahoma State University, Stillwater, OK 74078, USA.
| | | |
Collapse
|
14
|
Li H, Kang J, Ding L, Lü F, Fang Y. A dansyl-based fluorescent film: Preparation and sensitive detection of nitroaromatics in aqueous phase. J Photochem Photobiol A Chem 2008. [DOI: 10.1016/j.jphotochem.2007.12.029] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
15
|
Investigation of common fluorophores for the detection of nitrated explosives by fluorescence quenching. Anal Chim Acta 2008; 610:57-67. [DOI: 10.1016/j.aca.2008.01.016] [Citation(s) in RCA: 124] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2007] [Revised: 12/31/2007] [Accepted: 01/07/2008] [Indexed: 11/22/2022]
|
16
|
Tao S, Li Y, Li G, Yu C. A facile and efficient method for rapid detection of trace nitroaromatics in aqueous solution. ACTA ACUST UNITED AC 2008. [DOI: 10.1039/b802655f] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
17
|
Singh S. Sensors--an effective approach for the detection of explosives. JOURNAL OF HAZARDOUS MATERIALS 2007; 144:15-28. [PMID: 17379401 DOI: 10.1016/j.jhazmat.2007.02.018] [Citation(s) in RCA: 240] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2006] [Revised: 02/07/2007] [Accepted: 02/07/2007] [Indexed: 05/14/2023]
Abstract
The detection of explosives and explosive related illicit materials is an important area for preventing terrorist activities and for putting a check on their deleterious effects on health. A number of different methods, based on different principles, have been developed in the past for the detection of explosives. Sensors are one of those methods of detection which have capability to mimic the canine system and which are known to be the most reliable method of detection. The objective of this review is to provide comprehensive knowledge and information on the sensors operating on different transduction principles, ranging from electrochemical to immunosensors, being used for the detection of explosives as they pose a threat for both health and security of the nation. The review focuses mainly on the sensors developed in the recent 5 years and is prepared through summary of literature available on the subject.
Collapse
Affiliation(s)
- Suman Singh
- Central Mechanical Engineering Research Institute, M. G Avenue, Durgapur, 713209 West Bengal, India.
| |
Collapse
|
18
|
González-Martínez MA, Puchades R, Maquieira A. Optical immunosensors for environmental monitoring: How far have we come? Anal Bioanal Chem 2006; 387:205-18. [PMID: 17072601 DOI: 10.1007/s00216-006-0849-8] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2006] [Revised: 09/06/2006] [Accepted: 09/08/2006] [Indexed: 12/21/2022]
Abstract
Immunosensing has proved to be a very interesting research area. This review discusses what has actually been achieved in the field of optical immunosensing for environmental screening, and what still needs to be done. The review is presented from a practical point of view. In terms of the basic design of the immunosensor, there is a trend towards decreasing assay time; indeed, this has been reduced from 15-20 minutes to less than 5 minutes. Another goal is to simplify the manifold, and label-free approaches combining indirect assay formats and the detection of antibody binding are popular. Rapid displacement assays have also been investigated thoroughly. In terms of some important features of immunosensing devices, the reusability of the sensing element has been studied in great depth, and working lifetimes of more than five hundred assays can now be found for all assay formats. Multianalyte assays are now being investigated, and current systems are able to monitor 2-3 target compounds, although this number is set to increase greatly (to >30) in the near future. In this sense, an increasing number of publications can be found on microarrays intended for multianalyte determinations. The application of immunosensing to real situations is the main challenge. Immunosensors are barely commercialized and are yet to be established as research or routine tools, due to a lack of validated protocols for a wide range of sample matrices. Regarding compounds considered as analytes, some significant pollutants such as dioxins or pharmaceuticals are rarely chosen as targets, although the current tendency is towards a broader spectrum of analytes. New immunoreagents should be raised for these compounds, for use in immunosensors that can be used as screening tools.
Collapse
Affiliation(s)
- M A González-Martínez
- Departemento de Química, Universidad Politécnica de Valencia, 46022, Valencia, Spain
| | | | | |
Collapse
|
19
|
Shankaran DR, Kawaguchi T, Kim SJ, Matsumoto K, Toko K, Miura N. Evaluation of the molecular recognition of monoclonal and polyclonal antibodies for sensitive detection of 2,4,6-trinitrotoluene (TNT) by indirect competitive surface plasmon resonance immunoassay. Anal Bioanal Chem 2006; 386:1313-20. [PMID: 16900380 DOI: 10.1007/s00216-006-0699-4] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2006] [Revised: 07/16/2006] [Accepted: 07/19/2006] [Indexed: 11/25/2022]
Abstract
Detection of TNT is an important environmental and security concern all over the world. We herein report the performance and comparison of four immunoassays for rapid and label-free detection of 2,4,6-trinitrotoluene (TNT) based on surface plasmon resonance (SPR). The immunosensor surface was constructed by immobilization of a home-made 2,4,6-trinitrophenyl-keyhole limpet hemocyanin (TNPh-KLH) conjugate onto an SPR gold surface by simple physical adsorption within 10 min. The immunoreaction of the TNPh-KLH conjugate with four different antibodies, namely, monoclonal anti-TNT antibody (M-TNT Ab), monoclonal anti-trinitrophenol antibody (M-TNP Ab), polyclonal anti-trinitrophenyl antibody (P-TNPh Ab), and polyclonal anti-TNP antibody (P-TNP Ab), was studied by SPR. The principle of indirect competitive immunoreaction was employed for quantification of TNT. Among the four antibodies, the P-TNPh Ab prepared by our group showed highest sensitivity with a detection limit of 0.002 ng/mL (2 ppt) TNT. The lowest detection limits observed with other commercial antibodies were 0.008 ng/mL (8 ppt), 0.25 ng/mL (250 ppt), and 40 ng/mL (ppb) for M-TNT Ab, P-TNP Ab, and M-TNP Ab, respectively, in the similar assay format. The concentration of the conjugate and the antibodies were optimized for use in the immunoassay. The response time for an immunoreaction was 36 s and a single immunocycle could be done within 2 min, including the sensor surface regeneration using pepsin solution. In addition to the quantification of TNT, all immunoassays were evaluated for robustness and cross-reactivity towards several TNT analogs.
Collapse
Affiliation(s)
- Dhesingh Ravi Shankaran
- Art, Science and Technology Center for Cooperative Research, Kyushu University, Kasuga-shi, Fukuoka 816-8580, Japan.
| | | | | | | | | | | |
Collapse
|
20
|
|