1
|
Selective Membrane Sensor for Aluminum Determination in Food Products, Real Samples and Standard Alloys. MEMBRANES 2021; 11:membranes11070504. [PMID: 34209425 PMCID: PMC8308029 DOI: 10.3390/membranes11070504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 06/10/2021] [Accepted: 06/11/2021] [Indexed: 11/17/2022]
Abstract
The study involves the fabrication of an aluminum liquid membrane sensor based on the association of aluminum ions with the cited reagent 2,9-dimethyl-4,11-diphenyl -1,5,8,12-tetraaza cyclote tradeca-1,4,8,11-tetraene [DDTCT]. The characteristics slope (58 mV), rapid and linear response for aluminum ion was displayed by the proposed sensor within the concentration range 2.5 × 10-7-1.5 × 10-1 M, the detection limit (1.6 × 10-7) M, the selectivity behavior toward some metal cations, the response time 10 s), lifetime (150 days), the effect of pH on the suggested electrode potential and the requisite analytical validations were examined. The suitable pH range was (5.0-8.0 ), in this range the proposed electrode response is independent of pH. The suggested electrode was applied to detect the aluminum ions concentration in food products, real samples and standard alloys. The resulting data by the suggested electrode were statistically analyzed, and compared with the previously reported aluminum ion-selective electrodes in the literature.
Collapse
|
2
|
Cui T, Zhu X, Wu L, Tan X. Ultrasonic assisted dispersive liquid-liquid microextraction combined with flame atomic absorption spectrometry for determination of trace gallium in vanadium titanium magnetite. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104993] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
3
|
Katowah DF, Hussein MA, Alam MM, Sobahi TR, Gabal MA, Asiri AM, Rahman MM. Poly(pyrrole-co-o-toluidine) wrapped CoFe2O4/R(GO–OXSWCNTs) ternary composite material for Ga3+ sensing ability. RSC Adv 2019; 9:33052-33070. [PMID: 35529122 PMCID: PMC9073328 DOI: 10.1039/c9ra03593a] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 10/02/2019] [Indexed: 11/21/2022] Open
Abstract
A ternary P(Py-co-OT)/CF/R(GO–OXSWCNTs) nanocomposite has been fabricated as a novel conductive hybrid material with high stability and excellent electrochemical Ga3+ sensing ability.
Collapse
Affiliation(s)
- Dina F. Katowah
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| | - Mahmoud A. Hussein
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| | - M. M. Alam
- Department of Chemical Engineering and Polymer Science
- Shahjalal University of Science and Technology
- Sylhet 3100
- Bangladesh
| | - T. R. Sobahi
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| | - M. A. Gabal
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| | - Abdullah M. Asiri
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| | - Mohammed M. Rahman
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| |
Collapse
|
4
|
Jin Y, Zhao Y, Liu H, Sotto A, Gao C, Shen J. A durable and antifouling monovalent selective anion exchange membrane modified by polydopamine and sulfonated reduced graphene oxide. Sep Purif Technol 2018. [DOI: 10.1016/j.seppur.2018.06.053] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
5
|
Hussain MM, Asiri AM, Arshad MN, Rahman MM. Fabrication of a Ga3+ sensor probe based on methoxybenzylidenebenzenesulfonohydrazide (MBBSH) by an electrochemical approach. NEW J CHEM 2018. [DOI: 10.1039/c7nj01891f] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A thin-layer of (E)-N′-methoxybenzylidenebenzenesulfonohydrazide (MBBSH) was fabricated by the deposition of MBBSH onto a smooth glassy carbon electrode with nafion binder for the sensitive and selective Ga3+ sensor probe.
Collapse
Affiliation(s)
- Mohammad Musarraf Hussain
- Chemistry Department, Faculty of Science, King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
- Center of Excellence for Advanced Material Research, King Abdulaziz University
- Jeddah 21589
| | - Abdullah M. Asiri
- Chemistry Department, Faculty of Science, King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
- Center of Excellence for Advanced Material Research, King Abdulaziz University
- Jeddah 21589
| | - Muhammad Nadeem Arshad
- Chemistry Department, Faculty of Science, King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
- Center of Excellence for Advanced Material Research, King Abdulaziz University
- Jeddah 21589
| | - Mohammed M. Rahman
- Chemistry Department, Faculty of Science, King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
- Center of Excellence for Advanced Material Research, King Abdulaziz University
- Jeddah 21589
| |
Collapse
|
6
|
Sheikh TA, Arshad MN, Asiri AM, Rahman MM. Development of a selective and sensitive Ga3+ sensor for environmental safety: a comparative study of cyclohexyl and aromatic bis-sulphonamide fabricated glassy carbon electrodes. NEW J CHEM 2018. [DOI: 10.1039/c8nj02255k] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The aim of this study was to synthesize the new chelating agents CDBDMBS and PBDMBD for environmental remediation by sensing of Ga3+ in aqueous solution. The electrochemical technique is introduced a new approach of development of cost effective toxic cationic sensors for environmental and healthcare fields.
Collapse
Affiliation(s)
- Tahir Ali Sheikh
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| | | | - Abdullah M. Asiri
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| | - Mohammed M. Rahman
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| |
Collapse
|
7
|
Karimi Shervedani R, Garavand S, Samiei Foroushani M, Yaghoobi F. Electrochemical determination of Ga(III) through formation of Ga(III)-deferrioxamine B nanostructures on the glassy carbon electrode surface. Talanta 2015; 149:194-201. [PMID: 26717831 DOI: 10.1016/j.talanta.2015.11.056] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2015] [Revised: 11/19/2015] [Accepted: 11/21/2015] [Indexed: 12/15/2022]
Abstract
Selective and sensitive determination of Ga(III) in the presence of Fe(III), as the main interfering ion is studied by using glassy carbon electrode modified with deferrioxamine B (GC-DFO). Characterization and analytical application are performed by different methods including cyclic and differential pulse voltammetry (CV and DPV), electrochemical impedance spectroscopy (EIS), and Field Emission Scanning Electron Microscopy (FESEM). The DPV measurements showed two reduction peaks around -0.630 and -0.830V. While the current of both peaks varied linearly with Ga(III) concentration of the accumulation solution, the latter was more sensitive and used for construction of the calibration curve. The experimental parameters are studied and optimized. A dynamic calibration curve (6.0×10(-11) to 1.4×10(-9)molL(-1)), including a linear part, from 6.0×10(-11) to 1.0×10(-9)molL(-1) with mean RSDs of 5.3% for n=3 at 4.0×10(-10)molL(-1) Ga(III), and a detection limit of 2.0×10(-11) mol L(-1) Ga(III) is observed at the optimized conditions. The validity of the method and applicability of the sensor are successfully tested by determining of Ga(III) in natural (river) waters, rice and coal samples. The experimental data are presented and discussed from which the new sensor is characterized.
Collapse
Affiliation(s)
| | - Somayeh Garavand
- Department of Chemistry, University of Isfahan, Isfahan 81746-73441, I.R. IRAN
| | | | - Fatemeh Yaghoobi
- Department of Chemistry, University of Isfahan, Isfahan 81746-73441, I.R. IRAN
| |
Collapse
|
8
|
Automated separation of short-lived 72Ga from fresh fission products based on tandem column chromatography. J Radioanal Nucl Chem 2015. [DOI: 10.1007/s10967-015-4619-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
9
|
|
10
|
Hu Y, Zhang Z, Zhang H, Luo L, Zhang M, Yang X, Yao S. Electrochemical Sensor for Sensitive Determination of Ga(III) Ion Based on β-Cyclodextrin Incorporated Multi-walled Carbon Nanotubes and Imprinted Sol-gel Composite Film. CHINESE J CHEM 2012. [DOI: 10.1002/cjoc.201180474] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
11
|
Abbaspour A, Khoshfetrat SM, Sharghi H, Khalifeh R. Carbon nanotube composite coated platinum electrode for detection of Ga(III). JOURNAL OF HAZARDOUS MATERIALS 2011; 185:101-106. [PMID: 20980100 DOI: 10.1016/j.jhazmat.2010.09.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2010] [Revised: 09/01/2010] [Accepted: 09/01/2010] [Indexed: 05/30/2023]
Abstract
This study demonstrates the application of composite multi-walled carbon nanotube (MWCNT) polyvinylchloride (MWNT-PVC) based on 7-(2-hydroxy-5-methoxybenzyl)-5,6,7,8,9,10-hexahydro-2H benzo [b][1,4,7,10,13] dioxa triaza cyclopentadecine-3,11(4H,12H)-dione ionophore for gallium sensor. The sensor shows a good Nernstian slope of 19.68 ± 0.40 mV/decade in a wide linear range concentration of 7.9 × 10(-7) to 3.2 × 10(-2)M of Ga(NO(3))(3). The detection limit of this electrode is 5.2 × 10(-7)M of Ga(NO(3))(3). This proposed sensor is applicable in a pH range of 2.7-5.0. It has a short response time of about 10s and has a good selectivity over nineteen various metal ions. The practical analytical utility of this electrode is demonstrated by measurement of Ga(III) in river water.
Collapse
Affiliation(s)
- A Abbaspour
- Chemistry Department, College of Sciences, Shiraz University, Adabiat Crossroads, Shiraz 71456-85464, Iran.
| | | | | | | |
Collapse
|
12
|
Staff K, Brown MB, Hider RC, Kong XL, Friden P, Jones SA. Recovering Ga(III) from coordination complexes using pyridine 2,6-dicarboxylic acid chelation ion chromatography. Biomed Chromatogr 2010; 24:1015-22. [PMID: 20700886 DOI: 10.1002/bmc.1402] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Ion exchange chelation chromatography is an effective means to extract metals from coordination complexes and biological samples; however there is a lack of data to verify the nature of metal complexes that can be successfully analysed using such a procedure. The aim of this study was to assess the capability of pyridine 2,6-dicarboxylic acid (PDCA) to extract and quantify Ga(III) from a range of environments using standard liquid chromatography apparatus. The PDCA chelation method generated a single Ga(III) peak with a retention time of 2.55 +/- 0.02 min, a precision of <2% and a limit of detection of 110 microM. Ga(III) hydroxide complexes (highest stability constant 15.66) were used to successfully cross-validate the chelation method with inductively coupled plasma mass spectrometry. The PDCA assay extracted 96.9 +/- 1.2% of the spiked Ga(III) from porcine mucus and 100.7 +/- 2.7% from a citrate complex (stability constant 10.02), but only ca 50% from an EDTA complex (stability constant 22.01). These data suggest that PDCA chelation can be considered a suitable alternative to inductively coupled plasma mass spectrometry for Ga(III) quantification from all but the most strongly bound coordinated complexes i.e. a stability constant of <15.
Collapse
|
13
|
Gupta VK, Hamdan A, Pal MK. Gallium(III) selective sensors based on 2-amino-3-(α-N-phenylmethyl-2′-amino-1′,4′-naphthoquinonyl)-1,4 naphthoquinones in poly (vinyl chloride). Anal Chim Acta 2010; 673:139-44. [DOI: 10.1016/j.aca.2010.05.037] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2010] [Revised: 05/16/2010] [Accepted: 05/26/2010] [Indexed: 12/01/2022]
|
14
|
Wu CC, Liu HM. Determination of gallium in human urine by supercritical carbon dioxide extraction and graphite furnace atomic absorption spectrometry. JOURNAL OF HAZARDOUS MATERIALS 2009; 163:1239-1245. [PMID: 18771852 DOI: 10.1016/j.jhazmat.2008.07.093] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2008] [Revised: 07/20/2008] [Accepted: 07/21/2008] [Indexed: 05/26/2023]
Abstract
This study presents supercritical carbon dioxide (scCO(2)) extraction as an inherently safer and cleaner sample treatment method for identifying trace gallium in urine samples. Extraction is performed in the presence of a fluorinated beta-diketones chelating agent, 2,2-dimethyl-6,6,7,7,8,8,8-heptafluoro-3,5-octanedione (HFOD), by unmodified scCO(2). Quantitative extractions are conducted at 80 degrees C and 20.7 MPa with 15 min static plus 15 min dynamic extractions, and are followed by analysis via graphite furnace atomic absorption spectroscopy (GFAAS). The proposed procedure is successfully applied to determine the concentrations of gallium in real urine samples spiked with various levels of gallium with satisfactory recoveries of 90.8-100.3% (n=6) and relative standard deviations <10%. A standard reference material (SRM), Seronorm Trace Elements Urine, is used to validate the accuracy of the proposed method.
Collapse
Affiliation(s)
- Chia-Chan Wu
- Institute of Occupational Safety and Hazard Prevention, Hungkuang University, Shalu, Taichung 433, Taiwan, ROC
| | | |
Collapse
|
15
|
Faridbod F, Norouzi P, Dinarvand R, Ganjali MR. Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade. SENSORS (BASEL, SWITZERLAND) 2008; 8:2331-2412. [PMID: 27879825 PMCID: PMC3673421 DOI: 10.3390/s8042331] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2008] [Accepted: 04/02/2008] [Indexed: 12/07/2022]
Abstract
Many research studies have been conducted on the use of conjugated polymers in the construction of chemical sensors including potentiometric, conductometric and amperometric sensors or biosensors over the last decade. The induction of conductivity on conjugated polymers by treating them with suitable oxidizing agents won Heeger, MacDiarmid and Shirakawa the 2000 Nobel Prize in Chemistry. Common conjugated polymers are poly(acetylene)s, poly(pyrrole)s, poly(thiophene)s, poly(terthiophene)s, poly(aniline)s, poly(fluorine)s, poly(3-alkylthiophene)s, polytetrathiafulvalenes, polynapthalenes, poly(p-phenylene sulfide), poly(p-phenylenevinylene)s, poly(3,4-ethylenedioxythiophene), polyparaphenylene, polyazulene, polyparaphenylene sulfide, polycarbazole and polydiaminonaphthalene. More than 60 sensors for inorganic cations and anions with different characteristics based on conducting polymers have been reported. There have also been reports on the application of non-conducting polymers (nCPs), i.e. PVC, in the construction of potentiometric membrane sensors for determination of more than 60 inorganic cations and anions. However, the leakage of ionophores from the membranes based on these polymers leads to relatively lower life times. In this article, we try to give an overview of Solid-Contact ISE (SCISE), Single-Piece ISE (SPISE), Conducting Polymer (CP)-Based, and also non-conducting polymer PVC-based ISEs for various ions which their difference is in the way of the polymer used with selective membrane. In SCISEs and SPISEs, the plasticized PVC containing the ionophore and ionic additives govern the selectivity behavior of the electrode and the conducting polymer is responsible of ion-to-electron transducer. However, in CPISEs, the conducting polymer layer is doped with a suitable ionophore which enhances the ion selectivity of the CP while its redox response has to be suppressed.
Collapse
Affiliation(s)
- Farnoush Faridbod
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
| | - Parviz Norouzi
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
| | - Rassoul Dinarvand
- Medical Nanotechnology Research Centre, Medical Sciences/University of Tehran, Tehran, P.O. Box 14155-6451, Iran
| | - Mohammad Reza Ganjali
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran.
| |
Collapse
|