1
|
Yang B, Ye Z, Lu F, Yu J, Liu J, Zheng X, Wang C, Duan L, Yang Z, Jing G, Liu W, Li W, Liu W. High Resolving Power Electrospray Ionization Ion Mobility Spectrometer Based on Fourier Deconvolution Multiplexing. Anal Chem 2024; 96:17423-17431. [PMID: 39413295 DOI: 10.1021/acs.analchem.4c04549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2024]
Abstract
The resolving power of the drift tube ion mobility spectrometry (IMS) is mainly dependent on the drift length, the drift voltage, the pulse width of an ion gate, and the pressure inside the drift tube. Electrospray ionization (ESI)-IMS is a highly sensitive and reliable technique for the detection and analysis of nonvolatile compounds, and high resolving power is necessary to separate structurally similar compounds. To improve the analytical performance of atmospheric pressure ESI-IMS, the Fourier deconvolution (FD) multiplexing technique is investigated as an effective and convenient means to improve the resolving power as well as the signal-to-noise ratio. By reducing the equivalent ion gate opening width to 5 μs using a typical Tyndall-Powell ion shutter, a high resolving power RP up to 170 can be achieved with a drift length of 12 cm and a drift voltage of 10 kV. Rhodamine 6G (R6G), sodium dodecyl sulfate (SDS), methacycline, oxytetracycline, and ractopamine were evaluated using the FD-ESI-IMS, and mixtures with similar ion mobility can be well separated without prolonging the drift length.
Collapse
Affiliation(s)
- Binwang Yang
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Zhixiong Ye
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Feiyu Lu
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Jianna Yu
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Jiaxu Liu
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Xiuqing Zheng
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Cheng Wang
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Lian Duan
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Zhijian Yang
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Guoxing Jing
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Wen Liu
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Wenshan Li
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Wenjie Liu
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| |
Collapse
|
2
|
Vera P, Canellas E, Dreolin N, Goshawk J, Nerín C. The analysis of the migration of per and poly fluoroalkyl substances (PFAS) from food contact materials using ultrahigh performance liquid chromatography coupled to ion-mobility quadrupole time-of-flight mass spectrometry (UPLC- IMS-QTOF). Talanta 2024; 266:124999. [PMID: 37524039 DOI: 10.1016/j.talanta.2023.124999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 07/06/2023] [Accepted: 07/25/2023] [Indexed: 08/02/2023]
Abstract
Per-poly fluoroalkyl substances (PFASs) are a group of synthetic fluorine compounds used in food packaging materials to repel water and fats. This study assessed the chemical migration of PFAS from different food contact materials, including cardboard, recycled cardboard, biopolymer, paper and Teflon trays, from various markets. Migration assays were conducted using Tenax® as a food simulant, which was optimized by subjecting it to three consecutive extractions with 3 mL of ethanol within an hour. The resulting extractions were combined and concentrated to 0.5 mL using a nitrogen stream. The analysis was performed using ultrahigh performance liquid chromatography (UPLC) coupled with ion-mobility (IMS) quadrupole-time-of-flight (QTOF) mass spectrometry, which provided a powerful and novel tool for identifying a library of targets containing collision cross section values (CCS) and increasing confidence in subsequent identifications. Eleven PFAS compounds belonging to the family of perfluorocarboxylic acid, perfluorosulfonic acid and perfluorooctanesulfonamidoacetic acid substances (PFCAs, PFSAs and FOSAAs) were found in packaging samples obtained from China, with migrant concentrations ranging 3.2 and 22.3 μg/kg. In contrast, no detectable levels of PFAS were observed in packaging samples obtained in Spain. All trays tested were deemed to be suitable for use as food contact materials due to the fact that their migrant values were lower than 0.025 mg/kg for PFOA and its salts, and lower than a maximum concentration of 1 mg/kg for PFOA-related compounds.
Collapse
Affiliation(s)
- Paula Vera
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, M(a) de Luna 3, 50018, Zaragoza, Spain.
| | - Elena Canellas
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, M(a) de Luna 3, 50018, Zaragoza, Spain.
| | | | - Jeff Goshawk
- Waters Corporation, Wilmslow, SK9 4AX, United Kingdom.
| | - Cristina Nerín
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, M(a) de Luna 3, 50018, Zaragoza, Spain.
| |
Collapse
|
3
|
Meng Q, Jia X, Zhang H, Wang Z, Liu W. Almost perfect sequence modulated multiplexing ion mobility spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9329. [PMID: 35618651 DOI: 10.1002/rcm.9329] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 05/24/2022] [Accepted: 05/25/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE Multiplexing ion mobility spectrometry with multiple ion injection pulses was used to achieve a high duty cycle and thus improve the signal-to-noise (S/N) ratio while maintaining high resolving power compared with the traditional single-pulse signal averaging method. Historically, an ion mobility spectrum was reconstructed by various multiplexing methods including Fourier transform ion mobility spectrometry (FT-IMS), Hadamard transform ion mobility spectrometry (HT-IMS), and linear frequency modulation correlation ion mobility spectrometry (LFM-CIMS) sequence or Barker code. METHODS To achieve an artifact-free multiplexing ion mobility spectrum, an almost perfect sequence (APS) with correlation technique was proposed to modulate the Bradbury-Nielson ion gate and was compared with FT-IMS, HT-IMS, LFM-IMS, and the traditional single-pulse signal averaging method. RESULTS Experimental results showed that there are no artifact peaks in the APS-IMS spectra except an inverted mirror peak, and the S/N ratio was improved 5-8 times with a repetition time of 40-60 ms, corresponding to the improvement in the duty cycle. With the same duty cycle and similar acquisition time, APS-IMS showed a higher S/N ratio than HT-IMS for its unique autocorrelation response. CONCLUSIONS The APS-IMS technique offered a higher duty cycle and relatively shorter modulation period compared with reported multiplexing methods and is suitable to track rapidly changing signals without losing information and adding extra transformation artifact peaks.
Collapse
Affiliation(s)
- Qingyan Meng
- Key Laboratory of Biological Resource Protection and Utilization of Tarim Basin, Tarim University, Alar, Xinjiang, China
| | - Xu Jia
- Key Laboratory of Biological Resource Protection and Utilization of Tarim Basin, Tarim University, Alar, Xinjiang, China
| | - Hanghang Zhang
- Key Laboratory of Biological Resource Protection and Utilization of Tarim Basin, Tarim University, Alar, Xinjiang, China
| | - Zhiyan Wang
- Key Laboratory of Biological Resource Protection and Utilization of Tarim Basin, Tarim University, Alar, Xinjiang, China
| | - Wenjie Liu
- Key Laboratory of Biological Resource Protection and Utilization of Tarim Basin, Tarim University, Alar, Xinjiang, China
- College of Chemical Engineering, Xiangtan University, Xiangtan, Hunan, China
| |
Collapse
|
4
|
Moravský L, Michalczuk B, Fateh Borkhari A, Papp P, Sysoev AA, Matejčík Š. Study of atmospheric pressure chemical ionization of phthalates in air by ion mobility spectrometry/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9145. [PMID: 34142397 DOI: 10.1002/rcm.9145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 05/19/2021] [Accepted: 06/11/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE Phthalates are widely used in consumer products in the chemical industries. Due to their abundance in the milieu, their potentially harmful effect on the environment, human and animal health there is a need for sensitive and fast methods for their detection. METHODS Positive polarity Corona Discharge Atmospheric Pressure Chemical Ionization (CD-APCI) in the air was applied for ionization of phthalates. The ionization method for the phthalates was studied by atmospheric pressure Ion Mobility Spectrometry (IMS) and hybrid IMS/orthogonal acceleration Time-of-Flight Mass spectrometry (IMS-oaTOF-MS). RESULTS CD-APCI IMS and MS spectra of selected phthalates (dimethyl phthalate, diethyl phthalate, diethyl isophthalate, diethyl terephthalate, dipropyl phthalate, diisopropyl phthalate, dibutyl phthalate, diisobutyl phthalate, and dibutyl terephthalate) were recorded. In the case of the ortho- and "iso"-isomers exclusively the protonated molecular ions [M + H]+ were detected. In the case of the para- and meta-isomers and regioisomers, APCI resulted in the appearance of hydrated protonated molecular ions [M + H]+ ·(H2 O)0,1,2 . The ion mobilities, collision cross-sections of these ions in air, as well as the limits of detection (LODs) for the phthalate vapors, were determined. In the case of isomeric phthalates, we have demonstrated the potential of the IMS technique for their separation. CONCLUSIONS The results show that CD-APCI in combination with IMS and IMS-oaTOF-MS is a suitable method for the fast and sensitive detection of phthalates with the potential to separate some isomers.
Collapse
Affiliation(s)
- Ladislav Moravský
- Faculty of Mathematics, Physics and Informatics, Department of Experimental Physics, Comenius University in Bratislava, Bratislava, Slovakia
- National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow, Russia
| | - Bartosz Michalczuk
- Faculty of Mathematics, Physics and Informatics, Department of Experimental Physics, Comenius University in Bratislava, Bratislava, Slovakia
- Faculty of Exact and Natural Sciences, Siedlce University of Natural Sciences and Humanities, Siedlce, Poland
| | - Arian Fateh Borkhari
- Faculty of Mathematics, Physics and Informatics, Department of Experimental Physics, Comenius University in Bratislava, Bratislava, Slovakia
| | - Peter Papp
- Faculty of Mathematics, Physics and Informatics, Department of Experimental Physics, Comenius University in Bratislava, Bratislava, Slovakia
| | - Alexey A Sysoev
- National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow, Russia
| | - Štefan Matejčík
- Faculty of Mathematics, Physics and Informatics, Department of Experimental Physics, Comenius University in Bratislava, Bratislava, Slovakia
- National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow, Russia
| |
Collapse
|
5
|
Alikord M, Mohammadi A, Kamankesh M, Shariatifar N. Food safety and quality assessment: comprehensive review and recent trends in the applications of ion mobility spectrometry (IMS). Crit Rev Food Sci Nutr 2021; 62:4833-4866. [PMID: 33554631 DOI: 10.1080/10408398.2021.1879003] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Ion mobility spectrometry (IMS) is an analytical separation and diagnostic technique that is simple and sensitive and a rapid response and low-priced technique for detecting trace levels of chemical compounds in different matrices. Chemical agents and environmental contaminants are successfully detected by IMS and have been recently considered to employ in food safety. In addition, IMS uses stand-alone or coupled analytical diagnostic tools with chromatographic and spectroscopic methods. Scientific publications show that IMS has been applied 21% in the pharmaceutical industry, 9% in environmental studies and 13% in quality control and food safety. Nevertheless, applications of IMS in food safety and quality analysis have not been adequately explored. This review presents the IMS-related analysis and focuses on the application of IMS in food safety and quality. This review presents the important topics including detection of traces of chemicals, rate of food spoilage and freshness, food adulteration and authenticity as well as natural toxins, pesticides, herbicides, fungicides, veterinary, and growth promoter drug residues. Further, persistent organic pollutants (POPs), acrylamide, polycyclic aromatic hydrocarbon (PAH), biogenic amines, nitrosamine, furfural, phenolic compounds, heavy metals, food packaging materials, melamine, and food additives were also examined for the first time. Therefore, it is logical to predict that the application of the IMS technique in food safety, food quality, and contaminant analysis will be impressively increased in the future. HighlightsCurrent status of IMS for residues and contaminant detection in food safety.To assess all the detected contaminants in food safety, for the first time.Identified IMS-related parameters and chemical compounds in food safety control.
Collapse
Affiliation(s)
- Mahsa Alikord
- Department of Environmental Health, Food Safety Division, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| | - Abdorreza Mohammadi
- Department of Food Science and Technology, National Nutrition and Food Technology Research Institute, Faculty of Nutrition Sciences and Food Technology, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Marzieh Kamankesh
- Cellular and Molecular Research Center, Sabzevar University of Medical Sciences, Sabzevar, Iran
| | - Nabi Shariatifar
- Department of Environmental Health, Food Safety Division, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.,Halal Research Center of the Islamic Republic of Iran, Tehran, Iran
| |
Collapse
|
6
|
Ahrens A, Zimmermann S. Towards a hand-held, fast, and sensitive gas chromatograph-ion mobility spectrometer for detecting volatile compounds. Anal Bioanal Chem 2021; 413:1009-1016. [PMID: 33222000 PMCID: PMC7813738 DOI: 10.1007/s00216-020-03059-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 11/07/2020] [Accepted: 11/10/2020] [Indexed: 01/22/2023]
Abstract
Ion mobility spectrometers can detect gaseous compounds at atmospheric pressure in the range of parts per trillion within a second. Due to their fast response times, high sensitivity, and limited instrumental effort, they are used in a variety of applications, especially as mobile or hand-held devices. However, most real-life samples are gas mixtures, which can pose a challenge for IMS with atmospheric pressure chemical ionization mainly due to competing gas-phase ionization processes. Therefore, we present a miniaturized drift tube IMS coupled to a compact gas chromatograph for pre-separation, built of seven bundled standard GC columns (Rtx-Volatiles, Restek GmbH) with 250 μm ID and 1.07 m in length. Such pre-separation significantly reduces chemical cross sensitivities caused by competing gas-phase ionization processes and adds orthogonality. Our miniaturized GC-IMS system is characterized with alcohols, halocarbons, and ketones as model substances, reaching detection limits down to 70 pptv with IMS averaging times of just 125 ms. It separates test mixtures of ketones and halocarbons within 180 s and 50 s, respectively. The IMS has a short drift length of 40.6 mm and reaches a high resolving power of RP = 68. Graphical abstract.
Collapse
Affiliation(s)
- André Ahrens
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, 30167, Hannover, Germany.
| | - Stefan Zimmermann
- Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Appelstr. 9A, 30167, Hannover, Germany
| |
Collapse
|
7
|
Chen C, Tabrizchi M, Li H. Ion gating in ion mobility spectrometry: Principles and advances. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116100] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
8
|
Electrochemical Sodium Ion Sensor Based on Silver Nanoparticles/Graphene Oxide Nanocomposite for Food Application. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8030058] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
High sodium ion (Na+) consumption leads to high blood pressure which causes many health issues. Real-time determination of Na+ content in food is still important to limit Na+ intake and control the taste of food. In this work, we have developed an electrochemical sensor based on agglomeration of silver nanoparticles (AgNPs) and graphene oxide (GO) modified on a screen-printed silver electrode (SPE) for Na+ detection at room temperature by using cyclic voltammetry (CV). The AgNPs were synthesized through a simple green route using Pistia stratiotes extract as a reducing agent under blue light illumination and mixed with the GO to be a Na+ selective sensing nanocomposite. The AgNPs/GO/SPE sensor showed high sensitivity (0.269 mA/mM/cm2), high selectivity, linear relationship (0–100 mM), good stability, and excellent reproducibility to Na+ detection as well as low limit of detection (9.344 mM) for food application. The interfering species such as K+, Zn2+, Na+, Mg2+, glucose, and ascorbic acid did not have any influence on the Na+ determination. The AgNPs/GO/SPE sensor was successfully applied to determine Na+ in real samples such as fish sauce and seasoning powder of instant noodle.
Collapse
|
9
|
Sun T, Wang M, Wang D, Du Z. Solid-phase microextraction based on nickel-foam@polydopamine followed by ion mobility spectrometry for on-site detection of Sudan dyes in tomato sauce and hot-pot sample. Talanta 2020; 207:120244. [DOI: 10.1016/j.talanta.2019.120244] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Revised: 08/06/2019] [Accepted: 08/07/2019] [Indexed: 12/28/2022]
|
10
|
Guo C, Li K, Xing S, Sun H, Shi F, Zhang G, Sun H. Application of quadrupole-Orbitrap high-resolution mass spectrometry in rapid screening and identification of synthetic dyes in herbal medicines. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2019; 25:419-427. [PMID: 30764664 DOI: 10.1177/1469066719829872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In this work, a method combining ultra-high performance liquid chromatography and hybrid quadrupole-Orbitrap high-resolution mass spectrometry (HR-MS) was developed and validated for use in the simultaneous screening, identification, and quantification of 21 synthetic dyes in herbal medicines. To optimize the chromatographic conditions, we used a combined Full mass scan and data-dependent MS/MS (Full MS/dd-MS2) approach in positive and negative ion mode. Under this mode, selected ions with given fragmentation energy were subjected to a dd-MS2 scan following a Full MS scan. The selectivity of this method was effectively improved using 70,000 full width at half maximum mass resolution and narrow mass window (typically 5 ppm), and a single injection was sufficient for simultaneous identification and quantification of 21 synthetic dyes within 10 min. The combined method was fully validated and complies with all criteria for selectivity, sensitivity, calibration curve linearity, accuracy, precision, recovery, matrix effect, and stability. All analytes showed excellent linear relationships as all the coefficients of determination (r2) are greater than 0.9978 over wide ranges of concentrations (e.g. 1.0-500 ng/mL for sunset yellow). The validated method was employed to detect synthetic dyes in herbal medicines and was demonstrated to provide a reliable technical basis for drug regulation and public health protection.
Collapse
Affiliation(s)
- Changchuan Guo
- 1 Shandong Institute for Food and Drug Control, Jinan, Shandong, China
| | - Ke Li
- 2 School of Pharmaceutical science, Shandong University, Jinan, Shandong, China
| | - Sheng Xing
- 1 Shandong Institute for Food and Drug Control, Jinan, Shandong, China
| | - Hua Sun
- 1 Shandong Institute for Food and Drug Control, Jinan, Shandong, China
| | - Feng Shi
- 1 Shandong Institute for Food and Drug Control, Jinan, Shandong, China
| | - Guifang Zhang
- 3 Department of Pharmacy, Provincial Hospital Affiliated to Shandong University, Jinan, Shandong, China
| | - Haiyan Sun
- 4 School Hospital, Qilu University of Technology, Jinan, Shandong, China
| |
Collapse
|
11
|
Praveena SM, Cheema MS, Guo HR. Non-nutritive artificial sweeteners as an emerging contaminant in environment: A global review and risks perspectives. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2019; 170:699-707. [PMID: 30580164 DOI: 10.1016/j.ecoenv.2018.12.048] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 12/03/2018] [Accepted: 12/16/2018] [Indexed: 06/09/2023]
Abstract
Generally, non-nutritive artificial sweeteners are widely utilized as sugar substitute in various applications. With various applications, non-nutritive artificial sweeteners are now being recognized as emerging contaminants with high water persistence and are chemically stable in environment. Although non-nutritive artificial sweeteners were documented on their occurrence in environment, yet their potential impacts to environment and human health remain ambiguous. Therefore, this review was prepared to provide a more comprehensive insight of non-nutritive artificial sweeteners in environment matrixes by highlighting special concerns on human health and environmental risks. Precisely, this review monitors the exploration of non-nutritive artificial sweeteners occurrences as an emerging contaminants in environment worldwide and their associated risks to human as well as environment. At present, there are a total of 24 non-nutritive artificial sweeteners' studies with regards to their occurrence in the environment from 38 locations globally, spanning across Europe including United Kingdoms, Canada, United States and Asia. Overall, the quantitative findings suggested that the occurrence of non-nutritive artificial sweeteners is present in surface water, tap water, groundwater, seawater, lakes and atmosphere. Among these environmental matrixes, surface water was found as the most studied matrix involving non-nutritive artificial sweeteners. However, findings on non-nutritive artificial sweeteners impacts on human health and environment are limited to understanding its overall potential impacts and risks. Additionally, this review also serves as a framework for future monitoring plans and environmental legislative to better control these emerging contaminants in environment.
Collapse
Affiliation(s)
- Sarva Mangala Praveena
- Department of Environmental and Occupational Health, Faculty of Medicine and Health Science, Universiti Putra Malaysia, UPM, 43400 Serdang, Selangor, Malaysia.
| | - Manraj Singh Cheema
- Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia.
| | - How-Ran Guo
- Department of Environmental and Occupational Health, College of Medicine, National Cheng Kung University, 138 Sheng-Li Road, Tainan 704, Taiwan.
| |
Collapse
|
12
|
Michalczuk B, Moravský L, Papp P, Mach P, Sabo M, Matejčík Š. Isomer and conformer selective atmospheric pressure chemical ionisation of dimethyl phthalate. Phys Chem Chem Phys 2019; 21:13679-13685. [DOI: 10.1039/c9cp02069a] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The ionization mechanism of Atmospheric Pressure Chemical Ionization (APCI) for dimethyl phthalate isomers using an Ion Mobility Spectrometry (IMS) experiment combined with Density Functional Theory (DFT) calculations.
Collapse
Affiliation(s)
- Bartosz Michalczuk
- Department of Experimental Physics
- Comenius University
- 84248 Bratislava
- Slovakia
- Department of Chemistry
| | - Ladislav Moravský
- Department of Experimental Physics
- Comenius University
- 84248 Bratislava
- Slovakia
| | - Peter Papp
- Department of Experimental Physics
- Comenius University
- 84248 Bratislava
- Slovakia
| | - Pavel Mach
- Department of Nuclear Physics and Biophysics
- Comenius University
- Mlynská dolina F1
- 84248 Bratislava
- Slovakia
| | - Martin Sabo
- Department of Experimental Physics
- Comenius University
- 84248 Bratislava
- Slovakia
| | - Štefan Matejčík
- Department of Experimental Physics
- Comenius University
- 84248 Bratislava
- Slovakia
| |
Collapse
|
13
|
Guo K, Ni K, Song X, Li K, Tang B, Yu Q, Qian X, Wang X. Ion Distribution Profiling in an Ion Mobility Spectrometer by Laser-Induced Fluorescence. Anal Chem 2018; 90:4514-4520. [PMID: 29488746 DOI: 10.1021/acs.analchem.7b04912] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Measuring the ion distribution pattern in a drift tube under atmospheric pressure is very useful for studies of ion motion and design of ion mobility spectrometers (IMS); however, no mature method is available for conducting such measurements at present. We propose a simple and low-cost technique for profiling the two-dimensional ion distribution in any cross section of a drift tube. Similar to particle-image velocimetry, we first send sample ions with fluorescence properties into the drift tube and use a receiving plate to collect and accumulate them. Then, the receiving plate is illuminated by exciting light, and the ion distribution appears as a fluorescence image. In this study, Rhodamine 6G was selected as a typical fluorescence-tracer particle. Electrospray ionization (ESI) was chosen as an ionization source to keep the fluorophore undamaged. A plasma-cleaned coverslip was placed at the detection position as a receiving plate. When a layer of ions was collected, the slide was placed under the exciting light with a wavelength of 473 nm. A camera with a 490 nm high-pass light filter was used to capture the fluorescence image representing the ion distribution. The measured-ion detection efficiency of the method was 156 ion/dN, which is equivalent to the level of IonCCD. In addition, we studied the ion-passing characteristics of a Bradbury-Nielsen (BN) ion shutter and the ion-focusing effect in the drift tube using this method. The two-dimensional ion-distribution images behind the ion shutter and the images of the focused ion spot were first observed experimentally. Further theoretical analysis yielded the same conclusions as the experimental results, proving the feasibility of this method and producing a deeper understanding of ion motion in the IMS. This method has promising prospective application to the design, debugging, and optimization of IMS instruments and hyphenated systems.
Collapse
Affiliation(s)
- Kaitai Guo
- Division of Advanced Manufacturing, Graduate School at Shenzhen , Tsinghua University , Shenzhen 518055 , China
| | - Kai Ni
- Division of Advanced Manufacturing, Graduate School at Shenzhen , Tsinghua University , Shenzhen 518055 , China
| | - Xiangxiang Song
- Division of Advanced Manufacturing, Graduate School at Shenzhen , Tsinghua University , Shenzhen 518055 , China
| | - Kunxiao Li
- Division of Advanced Manufacturing, Graduate School at Shenzhen , Tsinghua University , Shenzhen 518055 , China
| | - Binchao Tang
- Division of Advanced Manufacturing, Graduate School at Shenzhen , Tsinghua University , Shenzhen 518055 , China
| | - Quan Yu
- Division of Advanced Manufacturing, Graduate School at Shenzhen , Tsinghua University , Shenzhen 518055 , China
| | - Xiang Qian
- Division of Advanced Manufacturing, Graduate School at Shenzhen , Tsinghua University , Shenzhen 518055 , China
| | - Xiaohao Wang
- Division of Advanced Manufacturing, Graduate School at Shenzhen , Tsinghua University , Shenzhen 518055 , China.,State Key Laboratory of Precision Measure Technology and Instruments , Tsinghua University , Beijing 100084 , China
| |
Collapse
|
14
|
Current applications and perspectives of ion mobility spectrometry to answer chemical food safety issues. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.07.006] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
15
|
Hagan N, Goldberg I, Graichen A, St Jean A, Wu C, Lawrence D, Demirev P. Ion Mobility Spectrometry - High Resolution LTQ-Orbitrap Mass Spectrometry for Analysis of Homemade Explosives. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1531-1539. [PMID: 28409445 DOI: 10.1007/s13361-017-1666-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Revised: 03/10/2017] [Accepted: 03/16/2017] [Indexed: 06/07/2023]
Abstract
The detailed chemical characterization of homemade explosives (HMEs) and other chemicals that can mimic or mask the presence of explosives is important for understanding and improving the performance of commercial instrumentation used for explosive detection. To that end, an atmospheric-pressure drift tube ion mobility spectrometry (IMS) instrument has been successfully coupled to a commercial tandem mass spectrometry (MS) system. The tandem MS system is comprised of a linear ion trap and a high resolution Orbitrap analyzer. This IMS-MS combination allows extensive characterization of threat chemical compounds, including HMEs, and complex real-world background chemicals that can interfere with detection. Here, the composition of ion species originating from a specific HME, erythritol tetranitrate, has been elucidated using accurate mass measurements, isotopic ratios, and tandem MS. Gated IMS-MS and high-resolution MS have been used to identify minor impurities that can be indicative of the HME source and/or synthesis route. Comparison between data obtained on the IMS/MS system and on commercial stand-alone IMS instruments used as explosive trace detectors (ETDs) has also been performed. Such analysis allows better signature assignments of threat compounds, modified detection algorithms, and improved overall ETD performance. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Nathan Hagan
- Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD, 20723, USA.
| | - Ilana Goldberg
- Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD, 20723, USA
| | - Adam Graichen
- Excellims Corporation, 20 Main Street, Acton, MA, 01720, USA
| | - Amanda St Jean
- Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD, 20723, USA
| | - Ching Wu
- Excellims Corporation, 20 Main Street, Acton, MA, 01720, USA
| | - David Lawrence
- Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD, 20723, USA
| | - Plamen Demirev
- Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD, 20723, USA
| |
Collapse
|
16
|
Xiao R, Zhang X, Zhang X, Niu J, Lu M, Liu X, Cai Z. Analysis of flavors and fragrances by HPLC with Fe 3 O 4 @GO magnetic nanocomposite as the adsorbent. Talanta 2017; 166:262-267. [DOI: 10.1016/j.talanta.2017.01.065] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Revised: 01/18/2017] [Accepted: 01/24/2017] [Indexed: 12/28/2022]
|
17
|
Data Fusion of ion Mobility Spectrometry Combined with Hierarchical Clustering Analysis for the Quality Assessment of Apple Essence. FOOD ANAL METHOD 2017. [DOI: 10.1007/s12161-017-0910-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
18
|
Liu W, Davis AL, Siems WF, Yin D, Clowers BH, Hill HH. Ambient Pressure Inverse Ion Mobility Spectrometry Coupled to Mass Spectrometry. Anal Chem 2017; 89:2800-2806. [DOI: 10.1021/acs.analchem.6b03727] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Wenjie Liu
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
- College
of Life Science, Tarim University, Alar, Xinjiang 843300, China
| | - Austen L. Davis
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| | - William F. Siems
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| | - Dulin Yin
- College of
Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, China
| | - Brian H. Clowers
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| | - Herbert H. Hill
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| |
Collapse
|
19
|
Yang X, Luo N, Tan Z, Jia Z, Liao X. A Fluorescence Probe for Tartrazine Detection in Foodstuff Samples Based on Fluorescence Resonance Energy Transfer. FOOD ANAL METHOD 2016. [DOI: 10.1007/s12161-016-0691-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
20
|
Browne CA, Forbes TP, Sisco E. Detection and identification of sugar alcohol sweeteners by ion mobility spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2016; 8:5611-5618. [PMID: 27574530 PMCID: PMC4999899 DOI: 10.1039/c6ay01554a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The rapid and sensitive detection of sugar alcohol sweeteners was demonstrated using ion mobility spectrometry (IMS). IMS provides a valuable alternative in sensitivity, cost, and analysis speed between the lengthy gold-standard liquid chromatography-mass spectrometry (LC-MS) technique and rapid point-of-measurement disposable colorimetric sensors, for the Food and Nutrition industry's quality control and other "foodomics" area needs. The IMS response, characteristic signatures, and limits of detection for erythritol, pentaerythritol, xylitol, inositol, sorbitol, mannitol, and maltitol were evaluated using precise inkjet printed samples. IMS system parameters including desorption temperature, scan time, and swipe substrate material were examined and optimized, demonstrating a strong dependence on the physicochemical properties of the respective sugar alcohol. The desorption characteristics of each compound were found to dominate the system response and overall sensitivity. Sugar alcohol components of commercial products - chewing gum and a sweetener packet - were detected and identified using IMS. IMS is demonstrated to be an advantageous field deployable instrument, easily operated by non-technical personnel, and enabling sensitive point-of-measurement quality assurance for sugar alcohols.
Collapse
Affiliation(s)
| | - Thomas P. Forbes
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD, USA
| | - Edward Sisco
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD, USA
| |
Collapse
|
21
|
Sha M, Zhang Z, Liu J, Wang H. Determination of Artificial Sweeteners by High-Performance Ion-Mobility Spectrometry with Electrospray Ionization. ANAL LETT 2016. [DOI: 10.1080/00032719.2016.1205079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
22
|
Zhao S, Yang X, Zhao H, Dong A, Wang J, Zhang M, Huang W. Water-compatible surface imprinting of ‘Saccharin sodium’ on silica surface for selective recognition and detection in aqueous solution. Talanta 2015; 144:717-25. [DOI: 10.1016/j.talanta.2015.05.086] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 05/22/2015] [Accepted: 05/25/2015] [Indexed: 11/24/2022]
|
23
|
Sabo M, Malásková M, Harmathová O, Hradski J, Masár M, Radjenovic B, Matejčík Š. Direct Liquid Sampling for Corona Discharge Ion Mobility Spectrometry. Anal Chem 2015; 87:7389-94. [DOI: 10.1021/acs.analchem.5b01585] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Martin Sabo
- Department
of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48, Bratislava, Slovakia
| | - Michaela Malásková
- Department
of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48, Bratislava, Slovakia
| | - Olga Harmathová
- Department
of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48, Bratislava, Slovakia
| | - Jasna Hradski
- Department
of Analytical Chemistry, Faculty of Natural Sciences, Comenius University in Bratislava, Mlynská dolina, Ilkovičova 6, 842 15, Bratislava, Slovakia
| | - Marián Masár
- Department
of Analytical Chemistry, Faculty of Natural Sciences, Comenius University in Bratislava, Mlynská dolina, Ilkovičova 6, 842 15, Bratislava, Slovakia
| | - Branislav Radjenovic
- Institute
of Physics, University of Belgrade, P.O. Box 57, 11080 Belgrade, Serbia
| | - Štefan Matejčík
- Department
of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48, Bratislava, Slovakia
| |
Collapse
|
24
|
Lehotay SJ, Sapozhnikova Y, Mol HG. Current issues involving screening and identification of chemical contaminants in foods by mass spectrometry. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.02.012] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
25
|
Emerging Contaminants. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/b978-0-444-63340-8.00010-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
26
|
Analysis of synthetic cathinones and associated psychoactive substances by ion mobility spectrometry. Forensic Sci Int 2014; 244:196-206. [DOI: 10.1016/j.forsciint.2014.08.033] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2014] [Revised: 08/25/2014] [Accepted: 08/29/2014] [Indexed: 11/22/2022]
|