1
|
Yuan T, Merai D, Gunsch MJ, Peters R, Lohani S, Bernardoni F, Zompa MA, Ahmad IH, Regalado EL, Pohl CA. Universal ion chromatography method for anions in active pharmaceutical ingredients enabled by computer-assisted separation modeling. J Pharm Biomed Anal 2024; 241:115923. [PMID: 38244392 DOI: 10.1016/j.jpba.2023.115923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 10/22/2023] [Accepted: 12/12/2023] [Indexed: 01/22/2024]
Abstract
Ion Chromatography (IC) is one of the most widely used methods for analyzing ionic species in pharmaceutical samples. A universal IC method that can separate a wide range of different analytes is highly desired as it can save a lot of time for method development and validation processes. Herein we report the development of a universal method for anions in active pharmaceutical ingredients (APIs) using computer-assisted chromatography modeling tools. We have screened three different IC columns (Dionex IonPac AS28-Fast 4 µm, AS19 4 µm and AS11-HC 4 µm) to determine the best suitable column for universal IC method development. A universal IC method was then developed using an AS11-HC 4 µm column to separate 31 most common anionic substances in 36 mins. This method was optimized using LC Simulator and a model which precisely predicts the retention behavior of 31 anions was established. This model demonstrated an excellent match between predicted and experimental analyte retention time (R2 =0.999). To validate this universal IC method, we have studied the stability of sulfite and sulfide analytes in ambient conditions. The method was then validated for a subset of 29 anions using water and organic solvent/water binary solvents as diluents for commercial APIs. This universal IC method provides an efficient and simple way to separate and analyze common anions in APIs. In addition, the method development process combined with LC simulator modeling can be effectively used as a starting point during method development for other ions beyond those investigated in this study.
Collapse
Affiliation(s)
- Tianyu Yuan
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA.
| | - Dolee Merai
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA
| | - Matthew J Gunsch
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA
| | - Ryan Peters
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA
| | - Sachin Lohani
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA
| | - Frank Bernardoni
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA
| | - Michael A Zompa
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA
| | - Imad Haidar Ahmad
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA
| | - Erik L Regalado
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA
| | | |
Collapse
|
2
|
Li D, Huang W, Huang R. Analysis of environmental pollutants using ion chromatography coupled with mass spectrometry: A review. JOURNAL OF HAZARDOUS MATERIALS 2023; 458:131952. [PMID: 37399723 DOI: 10.1016/j.jhazmat.2023.131952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 06/17/2023] [Accepted: 06/26/2023] [Indexed: 07/05/2023]
Abstract
The rise of emerging pollutants in the current environment and requirements of trace analysis in complex substrates pose challenges to modern analytical techniques. Ion chromatography coupled with mass spectrometry (IC-MS) is the preferred tool for analyzing emerging pollutants due to its excellent separation ability for polar and ionic compounds with small molecular weight and high detection sensitivity and selectivity. This paper reviews the progress of sample preparation and ion-exchange IC-MS methods in the analysis of several major categories of environmental polar and ionic pollutants including perchlorate, inorganic and organic phosphorus compounds, metalloids and heavy metals, polar pesticides, and disinfection by-products in past two decades. The comparison of various methods to reduce the influence of matrix effect and improve the accuracy and sensitivity of analysis are emphasized throughout the process from sample preparation to instrumental analysis. Furthermore, the human health risks of these pollutants in the environment with natural concentration levels in different environmental medias are also briefly discussed to raise public attention. Finally, the future challenges of IC-MS for analysis of environmental pollutants are briefly discussed.
Collapse
Affiliation(s)
- Dazhen Li
- Sichuan Provincial Key Laboratory of Universities on Environmental Science and Engineering, MOE Key Laboratory of Deep Earth Science and Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China
| | - Weixiong Huang
- Hubei Key Laboratory of Yangtze Catchment Environmental Aquatic Science, School of Environmental Studies, China University of Geosciences, Wuhan 430078, Hubei, China.
| | - Rongfu Huang
- Sichuan Provincial Key Laboratory of Universities on Environmental Science and Engineering, MOE Key Laboratory of Deep Earth Science and Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China.
| |
Collapse
|
3
|
Factors affecting mixed-mode retention properties of cation-exchange stationary phases. J Chromatogr A 2023; 1695:463934. [PMID: 36972662 DOI: 10.1016/j.chroma.2023.463934] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 03/07/2023] [Accepted: 03/15/2023] [Indexed: 03/19/2023]
Abstract
Cation-exchange stationary phases were characterized in different chromatographic modes (HILIC, RPLC, IC) and applied to the separation of non-charged hydrophobic and hydrophilic analytes. The set of columns under investigation included both commercially available cation-exchangers and self-prepared PS/DVB-based columns, the latter consisting of adjustable amounts of carboxylic and sulfonic acid functional groups. The influence of cation-exchange site and polymer substrate on the multimodal properties of cation-exchangers was identified using selectivity parameters, polymer imaging and excess adsorption isotherms. Introducing weakly acidic cation-exchange functional groups to the unmodified PS/DVB-substrate effectively reduced hydrophobic interactions, whilst a low degree of sulfonation (0.09 to 0.27% w/w sulphur) mainly influenced electrostatic interactions. Silica substrate was found to be another important factor for inducing hydrophilic interactions. The presented results demonstrate that cation-exchange resins are suitable for mixed-mode applications and offer versatile selectivity.
Collapse
|
4
|
Zuo Y, Cheng S, Jiang H, Zhang H, Wu J, Sun H, Zhu F, Li A, Huo Z, Li W. Rapid and simultaneous determination of dichloroacetic acid, trichloroacetic acid, ClO3−, ClO4−, and BrO3− using short-column ion chromatography-tandem electrospray mass spectrometry. Talanta 2023. [DOI: 10.1016/j.talanta.2022.124022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
5
|
Cheng S, Wu YP, Young TR, Dodd MC, Wu J, Zhang H, Huo ZL, Qian YT, Li Y, Li WT, Li AM. Rapid determination of trace haloacetic acids in water and wastewater using non-suppressed ion chromatography with electrospray ionization-tandem mass spectrometry. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 754:142297. [PMID: 33254877 DOI: 10.1016/j.scitotenv.2020.142297] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 08/23/2020] [Accepted: 09/07/2020] [Indexed: 06/12/2023]
Abstract
A simple and rapid method employing non-suppressed ion chromatography with electrospray ionization tandem mass spectrometry has been developed for the direct determination of trace-level haloacetic acids (HAAs) in water samples. Using 70/30 (v/v) acetonitrile/1 M aqueous methylamine as the mobile phase, three IC columns - AS16, AS18 and AS24 from Thermo-Scientific - were tested, respectively, with the AS16 column exhibiting the best overall performance with respect to resolution and retention time. To assess the effects of mobile phase composition on retention time of HAAs, the AS16 column was further tested using (i) different proportions of acetonitrile to aqueous methylamine, (ii) different proportions of acetonitrile to aqueous solution at fixed methylamine concentrations, and (iii) different concentrations of methylamine at fixed proportions of acetonitrile to aqueous solution. With a low proportion of aqueous solution, van der Waals and/or hydrogen-bonding interactions appeared to play an important role in governing HAA retention, i.e., HAAs with relatively higher apparent logKow* caused by elevated solvent sspKa exhibited longer retention times; whereas with a high proportion of aqueous solution, ionic interactions appeared to dominate retention of HAAs, with the more polarizable HAAs exhibiting longer retention times. Using 70/30 (v/v) acetonitrile/1 M aqueous methylamine, the method detection limits were in the range of 0.090-0.216 μg/L for the 11 selected chloro-, bromo- and iodoacetic acids. Finally, this method was applied to monitor HAAs yields in laboratory chlorination experiments and to determine concentrations of HAAs in tap water and wastewater effluent samples.
Collapse
Affiliation(s)
- Shi Cheng
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Ya-Ping Wu
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Tessora R Young
- Department of Civil and Environmental Engineering, University of Washington, Seattle, WA, USA
| | - Michael C Dodd
- Department of Civil and Environmental Engineering, University of Washington, Seattle, WA, USA
| | - Ji Wu
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Hao Zhang
- Jiangsu Province Center for Disease Control and Prevention, Nanjing, China
| | - Zong-Li Huo
- Jiangsu Province Center for Disease Control and Prevention, Nanjing, China.
| | - Yu-Ting Qian
- Jiangyin Environmental Monitoring Station, Jiangyin, China
| | - Yan Li
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Wen-Tao Li
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
| | - Ai-Min Li
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| |
Collapse
|
6
|
Alsaleh SA, Barron L, Sturzenbaum S. Perchlorate detection via an invertebrate biosensor. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:327-336. [PMID: 33392613 DOI: 10.1039/d0ay01732a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Improvised explosive devices (IEDs) are constructed from easily obtainable ingredients that are often unregulated and difficult to trace. Salts of the oxyhalide perchlorate are frequently used as oxidisers in IEDs and in commercially available munitions, thus a reliable detection is needed to aid forensic investigations and the tracing of environmental ground or surface water contamination. We introduce the nematode Caenorhabditis elegans as a biosensor for the presence of perchlorate, a promising alternative to the costly, technically challenging and time-consuming current perchlorate detection methods. Perchlorate uptake dynamics in C. elegans were first validated using ion exchange chromatography followed by assessing the effects of perchlorate on key life-point indices to verify the suitability of the nematodes as a forensic biosensor. Whole genome microarrays and qPCR analyses established that a set of immune and stress response genes were enriched during perchlorate exposure. A nematode strain (agIs219) containing an integrated copy of the significantly overexpressed t24b8.5 gene promoter followed by a GFP reporter gene was shown to fluoresce in a perchlorate dose dependent manner with a limit of detection (LOD) of 0.5 mg mL-1. Whilst chemicals commonly used in the construction of IEDs did not induce fluorescence, exposure to other oxyhalides did, highlighting the presence of possible shared stress response pathways. Burnt wire sparklers containing potassium perchlorate elicited fluorescence while other non-perchlorate containing post-blast explosion matrices did not. This demonstrates how C. elegans can be used to screen for perchlorate at environmental hotspots, an optimization, possibly with other target transgenes, is required to enable the detection of perchlorate at concentrations below 0.5 mg mL-1.
Collapse
Affiliation(s)
- Sana A Alsaleh
- Department of Analytical, Environmental & Forensic Sciences, School of Population Health & Environmental Sciences, Faculty of Life Sciences & Medicine, King's College London, London, UK.
| | | | | |
Collapse
|
7
|
Geerdink R, Hassing M, Ayarza N, Bruggink C, Wielheesen M, Claassen J, Epema O. Analysis of glyphosate, AMPA, Glufosinate and MPPA with ION chromatography tandem mass spectrometry using A membrane suppressor in the ammonium form application to surface water of low to moderate salinity. Anal Chim Acta 2020; 1133:66-76. [DOI: 10.1016/j.aca.2020.05.058] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 03/03/2020] [Accepted: 05/22/2020] [Indexed: 11/26/2022]
|
8
|
Corry TA, Jackson BA, Ray AD. Impurity analysis of 2-butynoic acid by ion chromatography-mass spectrometry. J Chromatogr A 2019; 1604:460470. [PMID: 31492467 DOI: 10.1016/j.chroma.2019.460470] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 08/15/2019] [Accepted: 08/20/2019] [Indexed: 10/26/2022]
Abstract
Small organic acids are widely used within the pharmaceutical industry but can be difficult to analyse. Ion chromatography is a suitable technique for the analysis of these acids but method development can be hindered as mass spectrometry is not often used as a detector; this means that peak tracking and peak purity cannot be performed. The authors report method development for the analysis of 2-butynoic acid, where by using electrospray ionisation mass spectrometry, peak purity was investigated and the presence of co-eluting impurities determined. Optimisation of the additives in the make-up flow to the mass spectrometer was shown to have an impact on the response observed. A standard series of organic acids were analysed spiked in to 2-butynoic acid at levels representative of impurities, the presence of the 2-butynoic acid did not impact the linearity or limit of detection observed for the acids; R2 values greater than 0.98 were obtained for all acids with and without the presence of 2-butynoic acid with a limit of detection at 1 ppb for all but one of the acids.
Collapse
Affiliation(s)
- Thomas A Corry
- Global Chemical Development, AstraZeneca, Charter Way, Macclesfield, Cheshire SK10 2NA, UK
| | - Bethany A Jackson
- Global Chemical Development, AstraZeneca, Charter Way, Macclesfield, Cheshire SK10 2NA, UK
| | - Andrew D Ray
- Global Product Development, AstraZeneca, Charter Way, Macclesfield, Cheshire SK10 2NA, UK.
| |
Collapse
|
9
|
Targeted and non-targeted forensic profiling of black powder substitutes and gunshot residue using gradient ion chromatography - high resolution mass spectrometry (IC-HRMS). Anal Chim Acta 2019; 1072:1-14. [PMID: 31146860 DOI: 10.1016/j.aca.2019.04.048] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Revised: 04/18/2019] [Accepted: 04/19/2019] [Indexed: 11/22/2022]
Abstract
A novel and simplified gradient IC-HRMS approach is presented in this work for forensic profiling of ionic energetic material residues, including low-order explosives and gunshot residue (GSR). This new method incorporated ethanolic eluents to facilitate direct coupling of IC and HRMS without auxiliary post-column infusion pumps that are traditionally used to assist with gas phase transfer. Ethanolic eluents also enabled better integration with an in-service protocol for direct analysis of high-order organic explosives by IC-HRMS, without requiring solvent exchange before injection. Excellent method performance was achieved, enabling both full scan qualitative and quantitative analysis, as required. In particular, linearity for 19 targeted compounds yielded R2 > 0.99 across several orders of magnitude, with trace analysis possible at the low-mid pg level. Reproducibility and mass accuracies were also excellent, with peak area %RSDs <10%, tR %RSDs <0.4% and δm/z < 3 ppm. The method was applied to targeted analysis of latent fingermarks and swabbed hand sweat samples to determine contact with a black-powder substitute containing nitrate, benzoate and perchlorate. When combined with principal component analysis (PCA), the effect of time since handling on recorded signals could be interpreted further in order to support forensic investigations. In a second, non-targeted application, PCA using full scan IC-HRMS data enabled classification of GSR from three different types of ammunition. An additional 20 markers of GSR were tentatively identified in silico, in addition to the 15 anions detected during targeted analysis. This new approach therefore streamlines and adds consistency and flexibility to forensic analysis of ionic energetic material. Furthermore, it also has implications for targeted, non-targeted and suspect screening applications in other fields by expanding the separation space to low molecular weight inorganic and organic anions.
Collapse
|
10
|
Uzhel AS, Gorbovskaya AV, Zatirakha AV, Smolenkov AD, Shpigun OA. Manipulating selectivity of covalently-bonded hyperbranched anion exchangers toward organic acids. Part I: Influence of primary amine substituents in the internal part of the functional layer. J Chromatogr A 2019; 1589:65-72. [DOI: 10.1016/j.chroma.2018.12.052] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 12/17/2018] [Accepted: 12/23/2018] [Indexed: 11/29/2022]
|
11
|
Kaufmann A, Widmer M, Maden K, Butcher P, Walker S. Analysis of a variety of inorganic and organic additives in food products by ion-pairing liquid chromatography coupled to high-resolution mass spectrometry. Anal Bioanal Chem 2018; 410:5629-5640. [DOI: 10.1007/s00216-018-0904-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 01/12/2018] [Accepted: 01/19/2018] [Indexed: 11/30/2022]
|
12
|
Gallidabino MD, Hamdan L, Murphy B, Barron LP. Suspect screening of halogenated carboxylic acids in drinking water using ion exchange chromatography – high resolution (Orbitrap) mass spectrometry (IC-HRMS). Talanta 2018; 178:57-68. [DOI: 10.1016/j.talanta.2017.08.092] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Revised: 08/25/2017] [Accepted: 08/29/2017] [Indexed: 10/18/2022]
|
13
|
Zhang Y, Fan J, Yang B, Huang W, Ma L. Copper-catalyzed activation of molecular oxygen for oxidative destruction of acetaminophen: The mechanism and superoxide-mediated cycling of copper species. CHEMOSPHERE 2017; 166:89-95. [PMID: 27689888 DOI: 10.1016/j.chemosphere.2016.09.066] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Revised: 08/18/2016] [Accepted: 09/15/2016] [Indexed: 06/06/2023]
Abstract
In this study, the commercial zero-valent copper (ZVC) was investigated to activate the molecular oxygen (O2) for the degradation of acetaminophen (ACT). 50 mg/L ACT could be completely decomposed within 4 h in the ZVC/air system at initial pH 3.0. The H2O2, hydroxyl radical (OH) and superoxide anion radical (O2-) were identified as the main reactive oxygen species (ROSs) generated in the above reaction; however, only OH caused the decomposition and mineralization of ACT in the copper-catalyzed O2 activation process. In addition, the in-situ generated Cu+ from ZVC dissolution not only activated O2 to produce H2O2, but also initiated the decomposition of H2O2 to generate OH. Meanwhile, the H2O2 could also be partly decomposed into O2-, which served as a mediator for copper cycling by reduction of Cu2+ to Cu+ in the ZVC/air system. Therefore, OH could be continuously generated; and then ACT was effectively degraded. Additionally, the effect of solution pH and the dosage of ZVC were also investigated. As a result, this study indicated the key behavior of the O2- during Cu-catalyzed activation of O2, which further improved the understanding of O2 activation mechanism by zero-valent metals.
Collapse
Affiliation(s)
- Yunfei Zhang
- National Engineering Research Center for Urban Pollution Control, State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, 200092 Shanghai, PR China; Department of Environmental Engineering, College of Chemistry and Environmental Engineering, Shenzhen University, 518060 Shenzhen, PR China
| | - Jinhong Fan
- National Engineering Research Center for Urban Pollution Control, State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, 200092 Shanghai, PR China.
| | - Bo Yang
- Department of Environmental Engineering, College of Chemistry and Environmental Engineering, Shenzhen University, 518060 Shenzhen, PR China.
| | - Wutao Huang
- National Engineering Research Center for Urban Pollution Control, State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, 200092 Shanghai, PR China
| | - Luming Ma
- National Engineering Research Center for Urban Pollution Control, State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, 200092 Shanghai, PR China
| |
Collapse
|
14
|
Gilchrist ES, Healy DA, Morris VN, Glennon JD. A review of oxyhalide disinfection by-products determination in water by ion chromatography and ion chromatography-mass spectrometry. Anal Chim Acta 2016; 942:12-22. [DOI: 10.1016/j.aca.2016.09.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Revised: 09/06/2016] [Accepted: 09/08/2016] [Indexed: 02/07/2023]
|
15
|
Peristyy A, Paull B, Nesterenko PN. Chromatographic behaviour of synthetic high pressure high temperature diamond in aqueous normal phase chromatography. J Chromatogr A 2016; 1470:59-69. [DOI: 10.1016/j.chroma.2016.09.076] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Revised: 09/30/2016] [Accepted: 09/30/2016] [Indexed: 10/20/2022]
|
16
|
Recent advances in capillary electrophoresis instrumentation for the analysis of explosives. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2015.08.005] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
17
|
Liu JM, Liu CC, Fang GZ, Wang S. Advanced analytical methods and sample preparation for ion chromatography techniques. RSC Adv 2015. [DOI: 10.1039/c5ra10348g] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The recently developed advanced ion chromatography techniques and the various sample preparation methods have been summarized in this mini-review.
Collapse
Affiliation(s)
- Jing-Min Liu
- Key Laboratory of Food Nutrition and Safety
- Ministry of Education
- Tianjin University of Science and Technology
- China
| | - Cui-Cui Liu
- Key Laboratory of Food Nutrition and Safety
- Ministry of Education
- Tianjin University of Science and Technology
- China
| | - Guo-Zhen Fang
- Key Laboratory of Food Nutrition and Safety
- Ministry of Education
- Tianjin University of Science and Technology
- China
| | - Shuo Wang
- Key Laboratory of Food Nutrition and Safety
- Ministry of Education
- Tianjin University of Science and Technology
- China
| |
Collapse
|