1
|
Balaban Hanoglu S, Harmanci D, Evran S, Timur S. Detection strategies of infectious diseases via peptide-based electrochemical biosensors. Bioelectrochemistry 2024; 160:108784. [PMID: 39094447 DOI: 10.1016/j.bioelechem.2024.108784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 07/21/2024] [Accepted: 07/24/2024] [Indexed: 08/04/2024]
Abstract
Infectious diseases have threatened human life for as long as humankind has existed. One of the most crucial aspects of fighting against these infections is diagnosis to prevent disease spread. However, traditional diagnostic methods prove insufficient and time-consuming in the face of a pandemic. Therefore, studies focusing on detecting viruses causing these diseases have increased, with a particular emphasis on developing rapid, accurate, specific, user-friendly, and portable electrochemical biosensor systems. Peptides are used integral components in biosensor fabrication for several reasons, including various and adaptable synthesis protocols, long-term stability, and specificity. Here, we discuss peptide-based electrochemical biosensor systems that have been developed over the last decade for the detection of infectious diseases. In contrast to other reports on peptide-based biosensors, we have emphasized the following points i) the synthesis methods of peptides for biosensor applications, ii) biosensor fabrication approaches of peptide-based electrochemical biosensor systems, iii) the comparison of electrochemical biosensors with other peptide-based biosensor systems and the advantages and limitations of electrochemical biosensors, iv) the pros and cons of peptides compared to other biorecognition molecules in the detection of infectious diseases, v) different perspectives for future studies with the shortcomings of the systems developed in the past decade.
Collapse
Affiliation(s)
- Simge Balaban Hanoglu
- Department of Biochemistry, Faculty of Science, Ege University, Bornova, Izmir 35100, Turkey.
| | - Duygu Harmanci
- Central Research Test and Analysis Laboratory, Application and Research Center, Ege University, Bornova, Izmir 35100, Turkey
| | - Serap Evran
- Department of Biochemistry, Faculty of Science, Ege University, Bornova, Izmir 35100, Turkey
| | - Suna Timur
- Department of Biochemistry, Faculty of Science, Ege University, Bornova, Izmir 35100, Turkey; Central Research Test and Analysis Laboratory, Application and Research Center, Ege University, Bornova, Izmir 35100, Turkey.
| |
Collapse
|
2
|
Yuan Z, Wang L, Chen J, Su W, Li A, Su G, Liu P, Zhou X. Electrochemical strategies for the detection of cTnI. Analyst 2021; 146:5474-5495. [PMID: 34515706 DOI: 10.1039/d1an00808k] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Acute myocardial infarction (AMI) is the main cause of death from cardiovascular diseases. Thus, early diagnosis of AMI is essential for the treatment of irreversible damage from myocardial infarction. Traditional electrocardiograms (ECG) cannot meet the specific detection of AMI. Cardiac troponin I (cTnI) is the main biomarker for the diagnosis of myocardial infarction, and the detection of cTnI content has become particularly important. In this review, we introduced and compared the advantages and disadvantages of various cTnI detection methods. We focused on the analysis and comparison of the main indicators and limitations of various cTnI biosensors, including the detection range, detection limit, specificity, repeatability, and stability. In particular, we pay more attention to the application and development of electrochemical biosensors in the diagnosis of cardiovascular diseases based on different biological components. The application of electrochemical microfluidic chips for cTnI was also briefly introduced in this review. Finally, this review also briefly discusses the unresolved challenges of electrochemical detection and the expectations for improvement in the detection of cTnI biosensing in the future.
Collapse
Affiliation(s)
- Zhipeng Yuan
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Li Wang
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Jun Chen
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Weiguang Su
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Anqing Li
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Guosheng Su
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Pengbo Liu
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | | |
Collapse
|
3
|
Vanova V, Mitrevska K, Milosavljevic V, Hynek D, Richtera L, Adam V. Peptide-based electrochemical biosensors utilized for protein detection. Biosens Bioelectron 2021; 180:113087. [PMID: 33662844 DOI: 10.1016/j.bios.2021.113087] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 02/04/2021] [Accepted: 02/10/2021] [Indexed: 02/07/2023]
Abstract
Proteins are generally detected as biomarkers for tracing or determining various disorders in organisms. Biomarker proteins can be tracked in samples with various origins and in different concentrations, revealing whether an organism is in a healthy or unhealthy state. In regard to detection, electrochemical biosensors are a potential fusion of electronics, chemistry, and biology, allowing for fast and early point-of-care detection from a biological sample with the advantages of high sensitivity, simple construction, and easy operation. Peptides present a promising approach as a biorecognition element when connected with electrochemical biosensors. The benefits of short peptides lie mainly in their good stability and selective affinity to a target analyte. Therefore, peptide-based electrochemical biosensors (PBEBs) represent an alternative approach for the detection of different protein biomarkers. This review provides a summary of the past decade of recently proposed PBEBs designed for protein detection, dividing them according to different protein types: (i) enzyme detection, including proteases and kinases; (ii) antibody detection; and (iii) other protein detection. According to these protein types, different sensing mechanisms are discussed, such as the peptide cleavage by a proteases, phosphorylation by kinases, presence of antibodies, and exploiting of affinities; furthermore, measurements are obtained by different electrochemical methods. A discussion and comparison of various constructions, modifications, immobilization strategies and different sensing techniques in terms of high sensitivity, selectivity, repeatability, and potential for practical application are presented.
Collapse
Affiliation(s)
- Veronika Vanova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Katerina Mitrevska
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Vedran Milosavljevic
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61 200, Brno, Czech Republic
| | - David Hynek
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61 200, Brno, Czech Republic
| | - Lukas Richtera
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61 200, Brno, Czech Republic
| | - Vojtech Adam
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61 200, Brno, Czech Republic.
| |
Collapse
|
4
|
Falk M, Psotta C, Cirovic S, Shleev S. Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6352. [PMID: 33171750 PMCID: PMC7664326 DOI: 10.3390/s20216352] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Revised: 11/03/2020] [Accepted: 11/04/2020] [Indexed: 12/14/2022]
Abstract
Non-invasive healthcare technologies are an important part of research and development nowadays due to the low cost and convenience offered to both healthcare receivers and providers. This work overviews the recent advances in the field of non-invasive electrochemical biosensors operating in secreted human physiological fluids, viz. tears, sweat, saliva, and urine. Described electrochemical devices are based on different electrochemical techniques, viz. amperometry, coulometry, cyclic voltammetry, and impedance spectroscopy. Challenges that confront researchers in this exciting area and key requirements for biodevices are discussed. It is concluded that the field of non-invasive sensing of biomarkers in bodily fluid is highly convoluted. Nonetheless, if the drawbacks are appropriately addressed, and the pitfalls are adroitly circumvented, the approach will most certainly disrupt current clinical and self-monitoring practices.
Collapse
Affiliation(s)
- Magnus Falk
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
| | - Carolin Psotta
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
- Aptusens AB, 293 94 Kyrkhult, Sweden
| | - Stefan Cirovic
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
| | - Sergey Shleev
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
- Aptusens AB, 293 94 Kyrkhult, Sweden
| |
Collapse
|
5
|
Ilea A, Andrei V, Feurdean CN, Băbțan AM, Petrescu NB, Câmpian RS, Boșca AB, Ciui B, Tertiș M, Săndulescu R, Cristea C. Saliva, a Magic Biofluid Available for Multilevel Assessment and a Mirror of General Health-A Systematic Review. BIOSENSORS-BASEL 2019; 9:bios9010027. [PMID: 30769890 PMCID: PMC6468816 DOI: 10.3390/bios9010027] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 02/01/2019] [Accepted: 02/09/2019] [Indexed: 02/07/2023]
Abstract
Background: Saliva has been recently proposed as an alternative to classic biofluid analyses due to both availability and reliability regarding the evaluation of various biomarkers. Biosensors have been designed for the assessment of a wide spectrum of compounds, aiding in the screening, diagnosis, and monitoring of pathologies and treatment efficiency. This literature review aims to present the development in the biosensors research and their utility using salivary assessment. Methods: a comprehensive literature search has been conducted in the PubMed database, using the keywords “saliva” and “sensor”. A two-step paper selection algorithm was devised and applied. Results: The 49 papers selected for the present review focused on assessing the salivary biomarkers used in general diseases, oral pathologies, and pharmacology. The biosensors proved to be reliable tools for measuring the salivary levels of biochemical metabolic compounds such as glucose, proteinases and proteins, heavy metals and various chemical compounds, microorganisms, oncology markers, drugs, and neurotransmitters. Conclusions: Saliva is a biofluid with a significant clinical applicability for the evaluation and monitoring of a patient’s general health. Biosensors designed for assessing a wide range of salivary biomarkers are emerging as promising diagnostic or screening tools for improving the patients’ quality of life.
Collapse
Affiliation(s)
- Aranka Ilea
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Vlad Andrei
- DMD, Rezident doctor in Periodontology, Clinical County Hospital, 540136 Târgu Mureș, Romania.
| | - Claudia Nicoleta Feurdean
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Anida-Maria Băbțan
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Nausica Bianca Petrescu
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Radu Septimiu Câmpian
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Adina Bianca Boșca
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Histology, Faculty of Medicine, 400349 Cluj, Romania.
| | - Bianca Ciui
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Analytical Chemistry, Faculty of Pharmacy, 400349 Cluj, Romania.
| | - Mihaela Tertiș
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Analytical Chemistry, Faculty of Pharmacy, 400349 Cluj, Romania.
| | - Robert Săndulescu
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Analytical Chemistry, Faculty of Pharmacy, 400349 Cluj, Romania.
| | - Cecilia Cristea
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Analytical Chemistry, Faculty of Pharmacy, 400349 Cluj, Romania.
| |
Collapse
|
6
|
Effects of redox label location on the performance of an electrochemical aptamer-based tumor necrosis factor-alpha sensor. Talanta 2018; 189:585-591. [PMID: 30086964 DOI: 10.1016/j.talanta.2018.07.055] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 07/16/2018] [Accepted: 07/17/2018] [Indexed: 11/21/2022]
Abstract
We report the development of an electrochemical aptamer-based sensor for real time detection of tumor necrosis factor-alpha. The focus of this study is to evaluate the effects of the redox label location on the overall sensor performance, including sensor stability, detection limit, reusability, and selectivity. Three aptamer probes, each labeled with methylene blue (MB) at a specific location, were designed and employed in the fabrication of the sensors. Among the three sensors, the sensor fabricated using an aptamer with the MB label located at the distal end has a detection limit of 100 pM and is regenerable. The sensor fabricated using an aptamer with an internal MB modification has a detection limit of 10 nM and is not regenerable. Both sensors can be employed in complex biological samples such as 50% urine and 50% saliva. However, the sensor fabricated with an aptamer with the MB label located at the proximal end suffers from poor reproducibility and is highly unstable, thus limiting its application as a sensor. On the bases of these results, placing the MB label at the distal end of the aptamer probe appears to be the most advantageous for this sensor design for it does not interfere with monolayer formation and target binding.
Collapse
|
7
|
Piccoli J, Hein R, El-Sagheer AH, Brown T, Cilli EM, Bueno PR, Davis JJ. Redox Capacitive Assaying of C-Reactive Protein at a Peptide Supported Aptamer Interface. Anal Chem 2018; 90:3005-3008. [PMID: 29411973 DOI: 10.1021/acs.analchem.7b05374] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Electrochemical immunosensors offer much in the potential translation of a lab based sensing capability to a useful "real world" platform. In previous work we have introduced an impedance-derived electrochemical capacitance spectroscopic analysis as supportive of a reagentless means of reporting on analyte target capture at suitably prepared mixed-component redox-active, antibody-modified interfaces. Herein we directly integrate receptive aptamers into a redox charging peptide support in enabling a label-free low picomolar analytical assay for C-reactive protein with a sensitivity that significantly exceeds that attainable with an analogous antibody interface.
Collapse
Affiliation(s)
- Julia Piccoli
- Institute of Chemistry , São Paulo State University (UNESP) , 14800-900 , Araraquara , São Paulo , Brazil
| | - Robert Hein
- Department of Chemistry , University of Oxford , South Parks Road , Oxford OX1 3QZ , U.K
| | - Afaf H El-Sagheer
- Department of Chemistry , University of Oxford , South Parks Road , Oxford OX1 3QZ , U.K.,Chemistry Branch, Department of Science and Mathematics, Faculty of Petroleum and Mining Engineering , Suez University , Suez 43721 , Egypt
| | - Tom Brown
- Department of Chemistry , University of Oxford , South Parks Road , Oxford OX1 3QZ , U.K
| | - Eduardo M Cilli
- Institute of Chemistry , São Paulo State University (UNESP) , 14800-900 , Araraquara , São Paulo , Brazil
| | - Paulo R Bueno
- Institute of Chemistry , São Paulo State University (UNESP) , 14800-900 , Araraquara , São Paulo , Brazil
| | - Jason J Davis
- Department of Chemistry , University of Oxford , South Parks Road , Oxford OX1 3QZ , U.K
| |
Collapse
|
8
|
Wu Y, Baker SL, Lai RY. Effects of DNA Probe Length on the Performance of a Dynamics-based Electrochemical Hg(II) Sensor. ELECTROANAL 2017. [DOI: 10.1002/elan.201700314] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Yao Wu
- Department of Chemistry; University of Nebraska-Lincoln; Lincoln NE 68588-0304
| | - Savannah L. Baker
- Department of Chemistry; University of Nebraska-Lincoln; Lincoln NE 68588-0304
| | - Rebecca Y. Lai
- Department of Chemistry; University of Nebraska-Lincoln; Lincoln NE 68588-0304
| |
Collapse
|
9
|
Hinman SS, Cheng Q. Bioinspired Assemblies and Plasmonic Interfaces for Electrochemical Biosensing. J Electroanal Chem (Lausanne) 2016; 781:136-146. [PMID: 28163664 PMCID: PMC5283611 DOI: 10.1016/j.jelechem.2016.05.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Electrochemical biosensing represents a collection of techniques that may be utilized for capture and detection of biomolecules in both simple and complex media. While the instrumentation and technological aspects play important roles in detection capabilities, the interfacial design aspects are of equal importance, and often, those inspired by nature produce the best results. This review highlights recent material designs, recognition schemes, and method developments as they relate to targeted electrochemical analysis for biological systems. This includes the design of electrodes functionalized with peptides, proteins, nucleic acids, and lipid membranes, along with nanoparticle mediated signal amplification mechanisms. The topic of hyphenated surface plasmon resonance assays is also discussed, as this technique may be performed concurrently with complementary and/or confirmatory measurements. Together, smart materials and experimental designs will continue to pave the way for complete biomolecular analyses of complex and technically challenging systems.
Collapse
Affiliation(s)
- Samuel S. Hinman
- Environmental Toxicology, University of California – Riverside, Riverside, CA 92521, USA
| | - Quan Cheng
- Environmental Toxicology, University of California – Riverside, Riverside, CA 92521, USA
- Department of Chemistry, University of California – Riverside, Riverside, CA 92521, USA
| |
Collapse
|
10
|
Tello A, Cao R, Marchant MJ, Gomez H. Conformational Changes of Enzymes and Aptamers Immobilized on Electrodes. Bioconjug Chem 2016; 27:2581-2591. [PMID: 27748603 DOI: 10.1021/acs.bioconjchem.6b00553] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Conformation constitutes a vital property of biomolecules, especially in the cases of enzymes and aptamers, and is essential in defining their molecular recognition ability. When biomolecules are immobilized on electrode surfaces, it is very important to have a control on all the possible conformational changes that may occur, either upon the recognition of their targets or by undesired alterations. Both enzymes and aptamers immobilized on electrodes are susceptible to conformational changes as a response to the nature of the charge of the surface and of the surrounding environment (pH, temperature, ionic strength, etc.). The main goal of this review is to analyze how the conformational changes of enzymes and aptamers immobilized on electrode surfaces have been treated in reports on biosensors and biofuel cells. This topic was selected due to insufficient information found on the actual conformational changes involved in the function of these bioelectrochemical devices despite its importance.
Collapse
Affiliation(s)
- Alejandra Tello
- Universidad Andres Bello , Bionanotechnology and Microbiology Lab, Center for Bioinformatics and Integrative Biology (CBIB), Facultad de Ciencias Biológicas, República 239, Santiago, Chile
| | - Roberto Cao
- Instituto de Química, Facultad de Ciencias, Pontificia Universidad Católica de Valparaíso , Avenida Universidad 330, Curauma, Valparaíso, Chile
| | - María José Marchant
- Instituto de Química, Facultad de Ciencias, Pontificia Universidad Católica de Valparaíso , Avenida Universidad 330, Curauma, Valparaíso, Chile
| | - Humberto Gomez
- Instituto de Química, Facultad de Ciencias, Pontificia Universidad Católica de Valparaíso , Avenida Universidad 330, Curauma, Valparaíso, Chile
| |
Collapse
|
11
|
Plácido A, de Oliveira Farias EA, Marani MM, Vasconcelos AG, Mafud AC, Mascarenhas YP, Eiras C, Leite JR, Delerue-Matos C. Layer-by-layer films containing peptides of the Cry1Ab16 toxin from Bacillus thuringiensis for potential biotechnological applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 61:832-41. [DOI: 10.1016/j.msec.2016.01.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2015] [Revised: 11/26/2015] [Accepted: 01/04/2016] [Indexed: 02/07/2023]
|