1
|
Khoubi J, Ghiasvand A, Bahrami A, Shahna FG, Farhadian M. An amide-based covalent organic framework chemically anchored on silica nanoparticles for headspace microextraction sampling of halogenated hydrocarbons in air. J Chromatogr A 2024; 1736:465387. [PMID: 39326383 DOI: 10.1016/j.chroma.2024.465387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2024] [Revised: 09/03/2024] [Accepted: 09/19/2024] [Indexed: 09/28/2024]
Abstract
A needle trap device (NTD) was developed using an amide-based covalent-organic framework (COF), chemically bonded to silica nanoparticles. The NTD was coupled with gas chromatography-flame ionization detection (GC-FID) and employed for the headspace microextraction analysis of halogenated hydrocarbons (HHCs) in the air. The adsorbent was characterized using Fourier-transform infrared spectroscopy (FT-IR), X-ray diffraction analysis (XRD), transmission electron microscopy (TEM), and field-emission scanning electron microscopy (FE-SEM) techniques. Optimal values for the experimental variables were assessed using response surface methodology (RSM) with a central composite design (CCD), thereby reducing the number of experiments, material consumption, costs, and time. The optimal values for desorption time and temperature were obtained 5 min and 260 °C, respectively. Breakthrough volume (BtV) was studied over the range of 0.5 - 3 times the occupational exposure limit (OEL) and its optimal value was found to be 1200 mL. The optimal sampling temperature and relative humidity (RH) were obtained 20 °C, and 15 %, respectively. The limits of detection (LODs) and limits of quantification (LOQs) were ranged from 0.013 to 0.077 μg l-1 and 0.041 to 0.21 μg l-1, respectively, with a linear dynamic range (LDR) of 0.04 to 100 μg l-1. The method's repeatability and reproducibility (RSD %) were observed over the ranges of 5.3 - 6.4 % and 4.7 -6.9 %, respectively. A statistically validated agreement was observed between the NTD-GC-FID method and the NIOSH 1003 standard procedure for the sampling and determination of HHCs in real workplace air samples, demonstrating the reliability and accuracy of the developed approach.
Collapse
Affiliation(s)
- Jamshid Khoubi
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran; Environmental Health Research Center, Research Institute for Health Development, Kurdistan University of Medical Sciences, Sanandaj, Iran
| | - Alireza Ghiasvand
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, Australia
| | - Abdulrahman Bahrami
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran.
| | - Farshid Ghorbani Shahna
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Maryam Farhadian
- Department of Biostatistics, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
2
|
Rahimpoor R, Soleymani-Ghoozhdi D, Firoozichahak A, Alizadeh S. Needle trap device technique: From fabrication to sampling. Talanta 2024; 276:126255. [PMID: 38776771 DOI: 10.1016/j.talanta.2024.126255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 03/17/2024] [Accepted: 05/11/2024] [Indexed: 05/25/2024]
Abstract
Needle Trap Device (NTD) as a novel, versatile, and eco-friendly technique has played an important role in analytical and environmental chemistry. The distinctive role of this interdisciplinary technique can be defended through the sampling and analysis of biological samples and industrial pollutants in gaseous and liquid environments. In recent years, significant efforts have been made to enhance the performance of the needle trap device resulting in the development of novel extraction routes by various packing materials with improved selectivity and enhanced adsorption characteristics. These achievements can lead to the facilitated pre-concentration of desired analytes. This review tries to have a comparative and comprehensive survey of the three important areas of NTD technique: I) Fabrication and preparation procedures of NTDs; II) Sampling techniques of pollutants using NTDs; and III) Employed materials as adsorbents in NTDs. In the packing-material section, the commercial and synthetic adsorbents such as carbon materials, metal-organic frameworks, aerogel, and polymers are considered. Furthermore, the limitations and potential areas for future development of the NTD technique are presented.
Collapse
Affiliation(s)
- Razzagh Rahimpoor
- Department of Occupational Health Engineering, Research Center for Health Sciences, School of Health, Larestan University of Medical Sciences, Larestan, Iran
| | | | - Ali Firoozichahak
- Department of Occupational Health, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Science, Gonabad, Iran.
| | - Saber Alizadeh
- Department of Chemistry, Bu-Ali-Sina University, Hamedan, Iran
| |
Collapse
|
3
|
Vejar-Vivar C, Millán-Santiago J, Mardones C, Lucena R, Cárdenas S. Polydopamine inner wall-coated hypodermic needle as microextraction device and electrospray emitter for the direct analysis of illicit drugs in oral fluid by ambient mass spectrometry. Talanta 2022; 249:123693. [PMID: 35751921 DOI: 10.1016/j.talanta.2022.123693] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 06/08/2022] [Accepted: 06/13/2022] [Indexed: 10/31/2022]
Abstract
In this article, polydopamine inner wall-coated hypodermic needles (PDA-HNs) are evaluated as both microextraction devices and electrospray ionization (ESI) emitters for determining selected illicit drugs (methamphetamine, cocaine, and methadone) in oral fluid samples. The PDA film, located in the inner wall of the needle, allows the extraction of the analytes at alkaline pH, where their hydrophobic character is promoted. The extracted analytes are finally eluted in a methanol/formic acid mixture that also acts as ESI solution. For this purpose, a dedicated interface based on the connection of a PEEK tube with the needle hub is proposed. This assembly allows delivering the ESI solution by the infusion syringe pump of the mass spectrometer, providing an efficient ESI on the tip of the needle. The double use of the PDA-HNs as microextraction devices and ESI emitters permits the determination of the target analytes with limits of detection and precision (expressed as relative standard deviation) values better than 2.4 μg/L and 17.6%, respectively. The accuracy was evaluated by analyzing independent spiked oral fluid samples, obtaining good results.
Collapse
Affiliation(s)
- Carmina Vejar-Vivar
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain; Departamento de Análisis Instrumental, Facultad de Farmacia, Universidad de Concepción, Concepción, Casilla 237, Correo 3, Concepción, Chile
| | - Jaime Millán-Santiago
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Claudia Mardones
- Departamento de Análisis Instrumental, Facultad de Farmacia, Universidad de Concepción, Concepción, Casilla 237, Correo 3, Concepción, Chile
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| |
Collapse
|
4
|
Jagirani MS, Soylak M. A review: Recent advances in solid phase microextraction of toxic pollutants using nanotechnology scenario. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105436] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
5
|
Lan H, Hartonen K, Riekkola ML. Miniaturised air sampling techniques for analysis of volatile organic compounds in air. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115873] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
6
|
|
7
|
Kędziora-Koch K, Rykowska I, Wasiak W. Needle-Trap Device (NTD) Packed with Reduced Graphene Oxide (rGO) for Sample Preparation Prior to the Determination of Polycyclic Aromatic Hydrocarbons (PAHs) from Aqueous Samples by Gas Chromatography–Mass spectrometry (GC-MS). ANAL LETT 2019. [DOI: 10.1080/00032719.2018.1563792] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Kamila Kędziora-Koch
- Department of Analytical Chemistry, Faculty of Chemistry, Adam Mickiewicz University, Poznań, Poland
| | - Iwona Rykowska
- Department of Analytical Chemistry, Faculty of Chemistry, Adam Mickiewicz University, Poznań, Poland
| | - Wiesław Wasiak
- Department of Analytical Chemistry, Faculty of Chemistry, Adam Mickiewicz University, Poznań, Poland
| |
Collapse
|
8
|
Azzouz A, Kailasa SK, Lee SS, J. Rascón A, Ballesteros E, Zhang M, Kim KH. Review of nanomaterials as sorbents in solid-phase extraction for environmental samples. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.08.009] [Citation(s) in RCA: 137] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
9
|
Zheng J, Huang J, Yang Q, Ni C, Xie X, Shi Y, Sun J, Zhu F, Ouyang G. Fabrications of novel solid phase microextraction fiber coatings based on new materials for high enrichment capability. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.08.021] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
10
|
Bagheri H, Golzari Aqda T, Enteshari Najafabadi M. Evaluation of prepared natural polymers in the extraction of chlorobenzenes from environmental samples: Sol–gel–based cellulose acetate-phenyltriethoxysilane fibers. Microchem J 2018. [DOI: 10.1016/j.microc.2018.07.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
11
|
Kędziora-Koch K, Wasiak W. Needle-based extraction techniques with protected sorbent as powerful sample preparation tools to gas chromatographic analysis: Trends in application. J Chromatogr A 2018; 1565:1-18. [DOI: 10.1016/j.chroma.2018.06.046] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 04/12/2018] [Accepted: 06/18/2018] [Indexed: 12/31/2022]
|
12
|
Three-dimensional nanofiber scaffolds are superior to two-dimensional mats in micro-oriented extraction of chlorobenzenes. Mikrochim Acta 2018; 185:322. [DOI: 10.1007/s00604-018-2858-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Accepted: 05/28/2018] [Indexed: 01/21/2023]
|
13
|
Wang F, Zheng Y, Qiu J, Liu S, Tong Y, Zhu F, Ouyang G. Graphene-based metal and nitrogen-doped carbon composites as adsorbents for highly sensitive solid phase microextraction of polycyclic aromatic hydrocarbons. NANOSCALE 2018; 10:10073-10078. [PMID: 29781022 DOI: 10.1039/c8nr01910j] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Herein, a graphene-based metal and nitrogen-doped carbon (GNC-Co) composite, derived from zeolite imidazolate framework-67 (ZIF-67)-graphene oxide composites, was successfully developed and applied as an excellent fiber coating for solid phase microextraction (SPME) with enhanced performance. The fabricated carbon has a hierarchically micro/mesoporous structure with a high specific surface area of 123 m2 g-1. The study found that pyrolytic graphene (G) has good adsorption properties for anthracene, phenanthrene, fluoranthene and pyrene, while pyrolytic ZIF-67 (NC-Co) has good adsorption properties for naphthalene, acenaphthylene, acenaphthylene and fluorene. Combined with the advantage of G and NC-Co, the synthesized composite GNC-Co enabled the integration of the unique properties of these two fascinating materials and proved to show better performance in the extraction of all polycyclic aromatic hydrocarbons (PAHs). Compared to the commercial PDMS fiber, the self-made fiber achieved GC responses about 2-9 times as high as those obtained by the commercial 30 μm PDMS fiber. Furthermore, the self-made fiber obtained low detection limits in the range of 0.01-0.74 ng L-1 and wide linearity under the optimized extraction conditions. Finally, the GNC-Co coated fiber was successfully used for the detection of PAHs in real river water samples, which proved the applicability of the method.
Collapse
Affiliation(s)
- Fuxin Wang
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, P. R. China.
| | | | | | | | | | | | | |
Collapse
|
14
|
Reyes-Garcés N, Gionfriddo E, Gómez-Ríos GA, Alam MN, Boyacı E, Bojko B, Singh V, Grandy J, Pawliszyn J. Advances in Solid Phase Microextraction and Perspective on Future Directions. Anal Chem 2017; 90:302-360. [DOI: 10.1021/acs.analchem.7b04502] [Citation(s) in RCA: 402] [Impact Index Per Article: 57.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
| | | | | | - Md. Nazmul Alam
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Ezel Boyacı
- Department of Chemistry, Middle East Technical University, Ankara 06800, Turkey
| | - Barbara Bojko
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, 85-067 Bydgoszcz, Poland
| | - Varoon Singh
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Jonathan Grandy
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| |
Collapse
|
15
|
Azari MR, Barkhordari A, Zendehdel R, Heidari M. A novel needle trap device with nanoporous silica aerogel packed for sampling and analysis of volatile aldehyde compounds in air. Microchem J 2017. [DOI: 10.1016/j.microc.2017.06.019] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
16
|
Kędziora K, Wasiak W. Extraction media used in needle trap devices—Progress in development and application. J Chromatogr A 2017; 1505:1-17. [DOI: 10.1016/j.chroma.2017.05.030] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Revised: 05/10/2017] [Accepted: 05/12/2017] [Indexed: 12/13/2022]
|
17
|
Barkhordari A, Azari MR, Zendehdel R, Heidari M. Analysis of formaldehyde and acrolein in the aqueous samples using a novel needle trap device containing nanoporous silica aerogel sorbent. ENVIRONMENTAL MONITORING AND ASSESSMENT 2017; 189:171. [PMID: 28321678 DOI: 10.1007/s10661-017-5885-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2016] [Accepted: 03/07/2017] [Indexed: 06/06/2023]
Abstract
In this research, a needle trap device (NTD) packed with nanoporous silica aerogel as a sorbent was used as a new technique for sampling and analysis of formaldehyde and acrolein compounds in aqueous and urine samples. The obtained results were compared with those of the commercial sorbent Carboxen1000. Active sampling was used and a 21-G needle was applied for extraction of gas in the sample headspace. The optimization of experimental parameters like salt addition, temperature and desorption time was done and the performance of the NTD for the extraction of the compounds was evaluated. The optimum temperature and time of desorption were 280 °C and 2 min, respectively. The ranges of limit of detection, limit of quantification and relative standard deviation (RSD) were 0.01-0.03 μg L-1, 0.03-0.1 μg L-1 and 2.8-7.3%, respectively. It was found that the NTD containing nanoporous silica aerogel had a better performance. Thus, this technique can be applied as an effective and reliable method for sampling and analysis of aldehyde compounds from different biological matrices like urine, exhalation and so on.
Collapse
Affiliation(s)
- Abdullah Barkhordari
- Department of Occupational Health, School of Public Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mansour R Azari
- Safety Promotion and Injury Prevention Research Center and Department of Occupational Health, School of Public Health, Shahid Beheshti University of Medical Science, Tehran, Iran.
| | - Rezvan Zendehdel
- Department of Occupational Health, School of Public Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mahmoud Heidari
- Department of Occupational Health, School of Public Health, Guilan University of Medical Sciences, Rasht, Iran
| |
Collapse
|
18
|
Song XY, Chen J, Shi YP. Different configurations of carbon nanotubes reinforced solid-phase microextraction techniques and their applications in the environmental analysis. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2016.11.006] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
19
|
Amanzadeh H, Yamini Y, Masoomi MY, Morsali A. Nanostructured metal–organic frameworks, TMU-4, TMU-5, and TMU-6, as novel adsorbents for solid phase microextraction of polycyclic aromatic hydrocarbons. NEW J CHEM 2017. [DOI: 10.1039/c7nj03225k] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Zn(ii) based metal–organic frameworks were coated onto stainless steel wire and applied to the headspace solid phase microextraction of PAHs.
Collapse
Affiliation(s)
| | | | | | - Ali Morsali
- Department of Chemistry
- Tarbiat Modares University
- Tehran
- Iran
| |
Collapse
|
20
|
Rocío-Bautista P, Pacheco-Fernández I, Pasán J, Pino V. Are metal-organic frameworks able to provide a new generation of solid-phase microextraction coatings? – A review. Anal Chim Acta 2016; 939:26-41. [DOI: 10.1016/j.aca.2016.07.047] [Citation(s) in RCA: 123] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Revised: 07/27/2016] [Accepted: 07/28/2016] [Indexed: 10/21/2022]
|