1
|
Abeywardena SBY, Yue Z, Wallace GG, Innis PC. Novel 3D textile structures and geometries for electrofluidics. Electrophoresis 2024; 45:1171-1181. [PMID: 38837441 DOI: 10.1002/elps.202400020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 05/03/2024] [Accepted: 05/14/2024] [Indexed: 06/07/2024]
Abstract
The integration of microfluidics with electric field control, commonly referred to as electrofluidics, has led to new opportunities for biomedical analysis. The requirement for closed microcapillary channels in microfluidics, typically formed via complex microlithographic fabrication approaches, limits the direct accessibility to the separation processes during conventional electrofluidic devices. Textile structures provide an alternative and low-cost approach to overcome these limitations via providing open and surface-accessible capillary channels. Herein, we investigate the potential of different 3D textile structures for electrofluidics. In this study, 12 polyester yarns were braided around nylon monofilament cores of different diameters to produce functional 3D core-shell textile structures. Capillary electrophoresis performances of these 3D core-shell textile structures both before and after removing the nylon core were evaluated in terms of mobility and bandwidth of a fluorescence marker compound. It was shown that the fibre arrangement and density govern the inherent capillary formation within these textile structures which also impacts upon the solute analyte mobility and separation bandwidth during electrophoretic studies. Core-shell textile structures with a 0.47 mm nylon core exhibited the highest fluorescein mobility and presented a narrower separation bandwidth. This optimal textile structure was readily converted to different geometries via a simple heat-setting of the central nylon core. This approach can be used to fabricate an array of miniaturized devices that possess many of the basic functionalities required in electrofluidics while maintaining open surface access that is otherwise impractical in classical approaches.
Collapse
Affiliation(s)
- Sujani B Y Abeywardena
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute (IPRI), Australian Institute for Innovative Materials (AIIM), Innovation Campus, University of Wollongong, North Wollongong, New South Wales, Australia
| | - Zhilian Yue
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute (IPRI), Australian Institute for Innovative Materials (AIIM), Innovation Campus, University of Wollongong, North Wollongong, New South Wales, Australia
| | - Gordon G Wallace
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute (IPRI), Australian Institute for Innovative Materials (AIIM), Innovation Campus, University of Wollongong, North Wollongong, New South Wales, Australia
| | - Peter C Innis
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute (IPRI), Australian Institute for Innovative Materials (AIIM), Innovation Campus, University of Wollongong, North Wollongong, New South Wales, Australia
| |
Collapse
|
2
|
Ha NS, de Raad M, Han LZ, Golini A, Petzold CJ, Northen TR. Faster, better, and cheaper: harnessing microfluidics and mass spectrometry for biotechnology. RSC Chem Biol 2021; 2:1331-1351. [PMID: 34704041 PMCID: PMC8496484 DOI: 10.1039/d1cb00112d] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Accepted: 07/01/2021] [Indexed: 12/14/2022] Open
Abstract
High-throughput screening technologies are widely used for elucidating biological activities. These typically require trade-offs in assay specificity and sensitivity to achieve higher throughput. Microfluidic approaches enable rapid manipulation of small volumes and have found a wide range of applications in biotechnology providing improved control of reaction conditions, faster assays, and reduced reagent consumption. The integration of mass spectrometry with microfluidics has the potential to create high-throughput, sensitivity, and specificity assays. This review introduces the widely-used mass spectrometry ionization techniques that have been successfully integrated with microfluidics approaches such as continuous-flow system, microchip electrophoresis, droplet microfluidics, digital microfluidics, centrifugal microfluidics, and paper microfluidics. In addition, we discuss recent applications of microfluidics integrated with mass spectrometry in single-cell analysis, compound screening, and the study of microorganisms. Lastly, we provide future outlooks towards online coupling, improving the sensitivity and integration of multi-omics into a single platform.
Collapse
Affiliation(s)
- Noel S Ha
- Biological Systems and Engineering, Lawrence Berkeley National Laboratory Berkeley CA USA
- US Department of Energy Joint BioEnergy Institute Emeryville CA USA
| | - Markus de Raad
- Environmental Genomics and Systems Biology, Biosciences, Lawrence Berkeley National Laboratory Berkeley CA USA
| | - La Zhen Han
- Environmental Genomics and Systems Biology, Biosciences, Lawrence Berkeley National Laboratory Berkeley CA USA
- US Department of Energy Joint Genome Institute Berkeley CA USA
| | - Amber Golini
- Environmental Genomics and Systems Biology, Biosciences, Lawrence Berkeley National Laboratory Berkeley CA USA
- US Department of Energy Joint Genome Institute Berkeley CA USA
| | - Christopher J Petzold
- Biological Systems and Engineering, Lawrence Berkeley National Laboratory Berkeley CA USA
- US Department of Energy Joint BioEnergy Institute Emeryville CA USA
| | - Trent R Northen
- Biological Systems and Engineering, Lawrence Berkeley National Laboratory Berkeley CA USA
- US Department of Energy Joint BioEnergy Institute Emeryville CA USA
- Environmental Genomics and Systems Biology, Biosciences, Lawrence Berkeley National Laboratory Berkeley CA USA
- US Department of Energy Joint Genome Institute Berkeley CA USA
| |
Collapse
|
3
|
Knowing more from less: miniaturization of ligand-binding assays and electrophoresis as new paradigms for at-line monitoring and control of mammalian cell bioprocesses. Curr Opin Biotechnol 2021; 71:55-64. [PMID: 34246047 DOI: 10.1016/j.copbio.2021.06.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 05/17/2021] [Accepted: 06/20/2021] [Indexed: 02/01/2023]
Abstract
Monitoring technologies for Process Analytical Technology (PAT) in mammalian cell cultures are often focusing on the same hand full parameters although a deeper knowledge and control of a larger panel of culture components would highly benefit process optimization, control and robustness. This short review highlights key advances in microfluidic affinity assays and microchip capillary electrophoresis (MCE). Aiming at the miniaturization and integration of PAT, these can detect at-line a variety of metabolites, proteins and Critical Quality Attributes (CQA's) in a bioprocess. Furthermore, discrete analytical components, which can potentially support the translation of increasingly mature microfluidic technologies towards this novel application, are also presented as a comprehensive toolbox ranging from sample preparation to signal acquisition.
Collapse
|
4
|
Xie Y, Rufo J, Zhong R, Rich J, Li P, Leong KW, Huang TJ. Microfluidic Isolation and Enrichment of Nanoparticles. ACS NANO 2020; 14:16220-16240. [PMID: 33252215 PMCID: PMC8164652 DOI: 10.1021/acsnano.0c06336] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Over the past decades, nanoparticles have increased in implementation to a variety of applications ranging from high-efficiency electronics to targeted drug delivery. Recently, microfluidic techniques have become an important tool to isolate and enrich populations of nanoparticles with uniform properties (e.g., size, shape, charge) due to their precision, versatility, and scalability. However, due to the large number of microfluidic techniques available, it can be challenging to identify the most suitable approach for isolating or enriching a nanoparticle of interest. In this review article, we survey microfluidic methods for nanoparticle isolation and enrichment based on their underlying mechanisms, including acoustofluidics, dielectrophoresis, filtration, deterministic lateral displacement, inertial microfluidics, optofluidics, electrophoresis, and affinity-based methods. We discuss the principles, applications, advantages, and limitations of each method. We also provide comparisons with bulk methods, perspectives for future developments and commercialization, and next-generation applications in chemistry, biology, and medicine.
Collapse
Affiliation(s)
- Yuliang Xie
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242, United States
| | - Joseph Rufo
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina 27708, United States
| | - Ruoyu Zhong
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina 27708, United States
| | - Joseph Rich
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26506, United States
| | - Kam W Leong
- Department of Biomedical Engineering, Columbia University, New York, New York 10032, United States
| | - Tony Jun Huang
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina 27708, United States
| |
Collapse
|
5
|
Jones J, Ha NS, Barajas AG, Chatziioannou AF, van Dam RM. Integration of High-Resolution Radiation Detector for Hybrid Microchip Electrophoresis. Anal Chem 2020; 92:3483-3491. [PMID: 31986878 PMCID: PMC7410349 DOI: 10.1021/acs.analchem.9b04827] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
For decades, there has been immense progress in miniaturizing analytical methods based on electrophoresis to improve sensitivity and to reduce sample volumes, separation times, and/or equipment cost and space requirements, in applications ranging from analysis of biological samples to environmental analysis to forensics. In the field of radiochemistry, where radiation-shielded laboratory space is limited, there has been great interest in harnessing the compactness, high efficiency, and speed of microfluidics to synthesize short-lived radiolabeled compounds. We recently proposed that analysis of these compounds could also benefit from miniaturization and have been investigating capillary electrophoresis (CE) and hybrid microchip electrophoresis (hybrid-MCE) as alternatives to the typically used high-performance liquid chromatography (HPLC). We previously showed separation of the positron-emission tomography (PET) imaging tracer 3'-deoxy-3'-fluorothymidine (FLT) from its impurities in a hybrid-MCE device with UV detection, with similar separation performance to HPLC, but with improved speed and lower sample volumes. In this paper, we have developed an integrated radiation detector to enable measurement of the emitted radiation from radiolabeled compounds. Though conventional radiation detectors have been incorporated into CE systems in the past, these approaches cannot be readily integrated into a compact hybrid-MCE device. We instead employed a solid-state avalanche photodiode (APD)-based detector for real-time, high-sensitivity β particle detection. The integrated system can reliably separate [18F]FLT from its impurities and perform chemical identification via coinjection with nonradioactive reference standard. This system can quantitate samples with radioactivity concentrations as low as 114 MBq/mL (3.1 mCi/mL), which is sufficient for analysis of radiochemical purity of radiopharmaceuticals.
Collapse
Affiliation(s)
- Jason Jones
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Physics & Biology in Medicine Interdepartmental
Graduate Program, David Geffen School of Medicine, University of California Los
Angeles, Los Angeles, CA 90095, USA
| | - Noel S. Ha
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Department of Bioengineering, Henry Samueli School of
Engineering and Applied Science, University of California Los Angeles, Los Angeles,
CA 90095, USA
| | - Alec G. Barajas
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Department of Chemistry & Biochemistry, University of
California Los Angeles, Los Angeles, CA 90095, USA
| | - Arion F. Chatziioannou
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Physics & Biology in Medicine Interdepartmental
Graduate Program, David Geffen School of Medicine, University of California Los
Angeles, Los Angeles, CA 90095, USA
- Department of Molecular & Medical Pharmacology,
University of California Los Angeles, Los Angeles, CA 90095, USA
| | - R. Michael van Dam
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Physics & Biology in Medicine Interdepartmental
Graduate Program, David Geffen School of Medicine, University of California Los
Angeles, Los Angeles, CA 90095, USA
- Department of Bioengineering, Henry Samueli School of
Engineering and Applied Science, University of California Los Angeles, Los Angeles,
CA 90095, USA
- Department of Molecular & Medical Pharmacology,
University of California Los Angeles, Los Angeles, CA 90095, USA
| |
Collapse
|
6
|
Ai Y, Zhang F, Wang C, Xie R, Liang Q. Recent progress in lab-on-a-chip for pharmaceutical analysis and pharmacological/toxicological test. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.06.026] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
7
|
Martucci DH, Todão FR, Shimizu FM, Fukudome TM, Schwarz SDF, Carrilho E, Gobbi AL, Oliveira ON, Lima RS. Auxiliary electrode oxidation for naked-eye electrochemical determinations in microfluidics: Towards on-the-spot applications. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.08.133] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
8
|
Xiao X, Zhou Y, Sun Y, Wang Q, Liu J, Huang J, Zhu X, Yang X, Wang K. Integration of cell-free protein synthesis and purification in one microfluidic chip for on-demand production of recombinant protein. BIOMICROFLUIDICS 2018; 12:054102. [PMID: 30271517 PMCID: PMC6136919 DOI: 10.1063/1.5042307] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 09/04/2018] [Indexed: 06/08/2023]
Abstract
Recombinant proteins have shown several benefits compared with their non-recombinant counterparts in protein therapeutics. However, there are still some problems with the storage and distribution of recombinant proteins, owing to their temperature sensitivity. Microfluidic chips can integrate different functional modules into a single device because of the advantages of integration and miniaturization, which have the special potential to synthesize drugs when and where they are needed most. Here, we integrated cell-free protein synthesis and purification into a microfluidic chip for the production of recombinant protein. The chip consisted of a main channel and a branch channel. The main channel included two pinches, which were filled with template DNA-modified agarose microbeads and nickel ion-modified agarose beads as the cell-free protein synthesis unit and protein purification unit, respectively. The reaction mixture for protein synthesis was introduced into the main channel and first passed through the protein synthesis unit where the target protein was synthesized; next, the reaction mixture passed through the protein purification unit where the target protein was captured; and, finally, pure protein was collected at the outlet when washing buffer and eluting buffer were sequentially introduced into the branch channel. Enhanced green fluorescent protein (EGFP) was used as the model to investigate the performance of our chip. One chip could produce 70 μl of EGFP solution (144.3 μg/ml, 10.1 μg) per batch, and another round of protein synthesis and purification could be performed after replacing or regenerating nickel ion-modified agarose beads. It should be possible to produce other recombinant proteins on demand with this chip by simply replacing the template DNA.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Xiaohai Yang
- Authors to whom correspondence should be addressed: and . Tel./Fax: +86-731-88821566
| | - Kemin Wang
- Authors to whom correspondence should be addressed: and . Tel./Fax: +86-731-88821566
| |
Collapse
|
9
|
Nys G, Fillet M. Microfluidics contribution to pharmaceutical sciences: From drug discovery to post marketing product management. J Pharm Biomed Anal 2018; 159:348-362. [DOI: 10.1016/j.jpba.2018.07.011] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 07/08/2018] [Accepted: 07/10/2018] [Indexed: 12/18/2022]
|
10
|
Drevinskas T, Telksnys L, Maruška A, Gorbatsova J, Kaljurand M. Capillary Electrophoresis Sensitivity Enhancement Based on Adaptive Moving Average Method. Anal Chem 2018; 90:6773-6780. [DOI: 10.1021/acs.analchem.8b00664] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Tomas Drevinskas
- Instrumental Analysis Open Access Centre, Faculty of Natural Sciences, Vytautas Magnus University, Vileikos 8, LT44404 Kaunas, Lithuania
- Department of Systems’ Analysis, Faculty of Informatics, Vytautas Magnus University, Vileikos 8, LT44404 Kaunas, Lithuania
| | - Laimutis Telksnys
- Department of Systems’ Analysis, Faculty of Informatics, Vytautas Magnus University, Vileikos 8, LT44404 Kaunas, Lithuania
- Recognition Processes Department, Institute of Mathematics and Informatics, Goštauto 12, LT01108 Vilnius, Lithuania
| | - Audrius Maruška
- Instrumental Analysis Open Access Centre, Faculty of Natural Sciences, Vytautas Magnus University, Vileikos 8, LT44404 Kaunas, Lithuania
| | - Jelena Gorbatsova
- Department of Chemistry, Faculty of Sciences, Tallinn University of Technology, Akadeemia tee 15, 12618 Tallinn, Estonia
| | - Mihkel Kaljurand
- Instrumental Analysis Open Access Centre, Faculty of Natural Sciences, Vytautas Magnus University, Vileikos 8, LT44404 Kaunas, Lithuania
- Department of Chemistry, Faculty of Sciences, Tallinn University of Technology, Akadeemia tee 15, 12618 Tallinn, Estonia
| |
Collapse
|
11
|
Ramos-Payán M, Ocaña-Gonzalez JA, Fernández-Torres RM, Llobera A, Bello-López MÁ. Recent trends in capillary electrophoresis for complex samples analysis: A review. Electrophoresis 2017; 39:111-125. [PMID: 28791719 DOI: 10.1002/elps.201700269] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Revised: 07/17/2017] [Accepted: 07/24/2017] [Indexed: 01/21/2023]
Abstract
CE has been a continuously evolving analytical methodology since its first introduction in the 1980s of the last century. The development of new CE separation procedures, the coupling of these systems to more sensitive and versatile detection systems, and the advances in miniaturization technology have allowed the application of CE to the resolution of new and complex analytical problems, overcoming the traditional disadvantages associated with this method. In the present work, different recent trends in CE and their application to the determination of high complexity samples (as biological fluids, individual cells, etc.) will be reviewed: capillary modification by different types of coatings, microfluidic CE, and online microextraction CE. The main advantages and disadvantages of the different proposed approaches will be discussed with examples of most recent applications.
Collapse
Affiliation(s)
- María Ramos-Payán
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, Seville, Spain
| | - Juan A Ocaña-Gonzalez
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, Seville, Spain
| | | | - Andreu Llobera
- Carl Zeiss Vision GmbH, Technology & Innovation, Aalen, Germany
| | | |
Collapse
|
12
|
Ha NS, Sadeghi S, van Dam RM. Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals. MICROMACHINES 2017; 8:E337. [PMID: 30400527 PMCID: PMC6190332 DOI: 10.3390/mi8110337] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 11/08/2017] [Accepted: 11/18/2017] [Indexed: 01/18/2023]
Abstract
Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET) or single photon emission tomography (SPECT) scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers) must undergo quality control (QC) testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i) pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii) radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a discussion of efforts to directly miniaturize the test or examples in the literature that could be implemented for miniaturized QC testing.
Collapse
Affiliation(s)
- Noel S Ha
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California Los Angeles, Los Angeles, CA 90095, USA.
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA.
| | - Saman Sadeghi
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA.
| | - R Michael van Dam
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California Los Angeles, Los Angeles, CA 90095, USA.
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA.
| |
Collapse
|
13
|
Phillips TM. Recent advances in CE and microchip-CE in clinical applications: 2014 to mid-2017. Electrophoresis 2017; 39:126-135. [PMID: 28853177 DOI: 10.1002/elps.201700283] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2017] [Revised: 08/09/2017] [Accepted: 08/10/2017] [Indexed: 11/11/2022]
Abstract
CE and microchip CE (ME) are powerful tools for the analysis of a number of different analytes and have been applied to a variety of clinical fields and human samples. This review will present an overview of the most recent applications of these techniques to different areas of clinical medicine during the period of 2014 to mid-2017. CE and ME have been applied to clinical chemistry, drug detection and monitoring, hematology, infectious diseases, oncology, endocrinology, neonatology, nephrology, and genetic screening. Samples examined range from serum, plasma, and urine to lest utilized materials such as tears, cerebral spinal fluid, sweat, saliva, condensed breath, single cells, and biopsy tissue. Examples of clinical applications will be given along with the various detection systems employed.
Collapse
Affiliation(s)
- Terry M Phillips
- Department of Pharmaceutics, School of Pharmacy, Virginia Commonwealth University, Richmond, VA, USA
| |
Collapse
|
14
|
Novel volumetric method for highly repeatable injection in microchip electrophoresis. Anal Chim Acta 2017; 985:129-140. [PMID: 28864183 DOI: 10.1016/j.aca.2017.05.037] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 05/22/2017] [Accepted: 05/22/2017] [Indexed: 12/25/2022]
Abstract
A novel injector for microchip electrophoresis (MCE) has been designed and evaluated that achieves very high repeatability of injection volume suitable for quantitative analysis. It eliminates the injection biases in electrokinetic injection and the dependence on pressure and sample properties in hydrodynamic injection. The microfluidic injector, made of poly(dimethylsiloxane) (PDMS), operates similarly to an HPLC injection valve. It contains a channel segment (chamber) with a well-defined volume that serves as an "injection loop". Using on-chip microvalves, the chamber can be connected to the sample source during the "loading" step, and to the CE separation channel during the "injection" step. Once the valves are opened in the second state, electrophoretic potential is applied to separate the sample. For evaluation and demonstration purposes, the microinjector was connected to a 75 μm ID capillary and UV absorbance detector. For single compounds, a relative standard deviation (RSD) of peak area as low as 1.04% (n = 11) was obtained, and for compound mixtures, RSD as low as 0.40% (n = 4) was observed. Using the same microchip, the performance of this new injection technique was compared to hydrodynamic injection and found to have improved repeatability and less dependence on sample viscosity. Furthermore, a non-radioactive version of the positron-emission tomography (PET) imaging probe, FLT, was successfully separated from its known 3 structurally-similar byproducts with baseline resolution, demonstrating the potential for rapid, quantitative analysis of impurities to ensure the safety of batches of short-lived radiotracers. Both the separation efficiency and injection repeatability were found to be substantially higher when using the novel volumetric injection approach compared to electrokinetic injection (performed in the same chip). This novel microinjector provides a straightforward way to improve the performance of hydrodynamic injection and enables extremely repeatable sample volume injection in MCE. It could be used in any MCE application where volume repeatability is needed, including the quantitation of impurities in pharmaceutical or radiopharmaceutical samples.
Collapse
|
15
|
Zamfir AD. Microfluidics-Mass Spectrometry of Protein-Carbohydrate Interactions: Applications to the Development of Therapeutics and Biomarker Discovery. Methods Mol Biol 2017; 1647:109-128. [PMID: 28808998 DOI: 10.1007/978-1-4939-7201-2_7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The functional interactions of carbohydrates and their protein receptors are the basis of biological events critical to the evolution of pathological states. Hence, for the past years, such interactions have become the focus of research for the development of therapeutics and discovery of novel glycan biomarkers based on their binding affinity. Due to the high sensitivity, throughput, reproducibility, and capability to ionize minor species in heterogeneous mixtures, microfluidics-mass spectrometry (MS) has recently emerged as a method of choice in protein-glycan interactomics. In this chapter, a straightforward microfluidics-based MS methodology for the assessment of protein-glycan interactions is presented. The general protocol encompasses: (1) submission of the interacting partners to a binding assay under conditions mimicking the in vivo environment; and (2) screening of the reaction products and their structural characterization by fully automated chip-nanoelectrospray (nanoESI) MS and multistage MS. The first section of the chapter is devoted to describing a method that enables the study of protein-oligosaccharide interactions by chip-nanoESI quadrupole time-of-flight (QTOF) MS and top-down complex analysis by collision-induced dissociation (CID). This section provides the protocol for the determination of the complex formed by standard β-lactoglobulin (BLG) with maltohexaose (Glc6) and recommends as a concrete application the study of the interaction between BLG extracted from human milk with Glc6, considered a ligand able to reduce the allergenicity of this protein. The second part is dedicated to presenting the protocols for the binding assay followed by chip-nanoESI ion trap (ITMS) and electron transfer dissociation (ETD) in combination with CID for protein-ganglioside interactions, using as an example the B subunit of cholera toxin (Ctb5) in interaction with comercially available GM1 species. The methodology described may be successfully applied to native ganglioside mixtures from human brain, in particular for discovery of biomarkers on the basis of their binding affinity.
Collapse
Affiliation(s)
- Alina D Zamfir
- Mass Spectrometry Laboratory, National Institute for Research and Development in Electrochemistry and Condensed Matter, Plautius Andronescu Str.1, 300224, Timisoara, Romania.
| |
Collapse
|