1
|
Diep Trinh TN, Trinh KTL, Lee NY. Microfluidic advances in food safety control. Food Res Int 2024; 176:113799. [PMID: 38163712 DOI: 10.1016/j.foodres.2023.113799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 11/23/2023] [Accepted: 12/02/2023] [Indexed: 01/03/2024]
Abstract
Food contamination is a global concern, particularly in developing countries. Two main types of food contaminants-chemical and biological-are common problems that threaten human health. Therefore, rapid and accurate detection methods are required to address the threat of food contamination. Conventional methods employed to detect these two types of food contaminants have several limitations, including high costs and long analysis time. Alternatively, microfluidic technology, which allows for simple, rapid, and on-site testing, can enable us to control food safety in a timely, cost-effective, simple, and accurate manner. This review summarizes advances in microfluidic approaches to detect contaminants in food. Different detection methods have been applied to microfluidic platforms to identify two main types of contaminants: chemical and biological. For chemical contaminant control, the application of microfluidic approaches for detecting heavy metals, pesticides, antibiotic residues, and other contaminants in food samples is reviewed. Different methods including enzymatic, chemical-based, immunoassay-based, molecular-based, and electrochemical methods for chemical contaminant detection are discussed based on their working principle, the integration in microfluidic platforms, advantages, and limitations. Microfluidic approaches for foodborne pathogen detection, from sample preparation to final detection, are reviewed to identify foodborne pathogens. Common methods for foodborne pathogens screening, namely immunoassay, nucleic acid amplification methods, and other methods are listed and discussed; highlighted examples of recent studies are also reviewed. Challenges and future trends that could be employed in microfluidic design and fabrication process to address the existing limitations for food safety control are also covered. Microfluidic technology is a promising tool for food safety control with high efficiency and applicability. Miniaturization, portability, low cost, and samples and reagents saving make microfluidic devices an ideal choice for on-site detection, especially in low-resource areas. Despite many advantages of microfluidic technology, the wide manufacturing of microfluidic devices still demands intensive studies to be conducted for user-friendly and accurate food safety control. Introduction of recent advances of microfluidic devices will build a comprehensive understanding of the technology and offer comparative analysis for future studies and on-site application.
Collapse
Affiliation(s)
- Thi Ngoc Diep Trinh
- Department of Materials Science, School of Applied Chemistry, Tra Vinh University, Viet Nam
| | - Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Republic of Korea.
| |
Collapse
|
2
|
Liao X, Zhang Y, Zhang Q, Zhou J, Ding T, Feng J. Advancing point-of-care microbial pathogens detection by material-functionalized microfluidic systems. Trends Food Sci Technol 2023. [DOI: 10.1016/j.tifs.2023.03.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
|
3
|
Trinh KTL, Thai DA, Lee NY. Bonding Strategies for Thermoplastics Applicable for Bioanalysis and Diagnostics. MICROMACHINES 2022; 13:1503. [PMID: 36144126 PMCID: PMC9501821 DOI: 10.3390/mi13091503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 09/05/2022] [Accepted: 09/08/2022] [Indexed: 06/16/2023]
Abstract
Microfluidics is a multidisciplinary science that includes physics, chemistry, engineering, and biotechnology. Such microscale systems are receiving growing interest in applications such as analysis, diagnostics, and biomedical research. Thermoplastic polymers have emerged as one of the most attractive materials for microfluidic device fabrication owing to advantages such as being optically transparent, biocompatible, cost-effective, and mass producible. However, thermoplastic bonding is a key challenge for sealing microfluidic devices. Given the wide range of bonding methods, the appropriate bonding approach should be carefully selected depending on the thermoplastic material and functional requirements. In this review, we aim to provide a comprehensive overview of thermoplastic fabricating and bonding approaches, presenting their advantages and disadvantages, to assist in finding suitable microfluidic device bonding methods. In addition, we highlight current applications of thermoplastic microfluidics to analyses and diagnostics and introduce future perspectives on thermoplastic bonding strategies.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea
| | - Duc Anh Thai
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea
| |
Collapse
|
4
|
Mi F, Hu C, Wang Y, Wang L, Peng F, Geng P, Guan M. Recent advancements in microfluidic chip biosensor detection of foodborne pathogenic bacteria: a review. Anal Bioanal Chem 2022; 414:2883-2902. [PMID: 35064302 PMCID: PMC8782221 DOI: 10.1007/s00216-021-03872-w] [Citation(s) in RCA: 53] [Impact Index Per Article: 26.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 12/16/2021] [Accepted: 12/28/2021] [Indexed: 12/19/2022]
Abstract
Foodborne diseases caused by pathogenic bacteria pose a serious threat to human health. Early and rapid detection of foodborne pathogens is an urgent task for preventing disease outbreaks. Microfluidic devices are simple, automatic, and portable miniaturized systems. Compared with traditional techniques, microfluidic devices have attracted much attention because of their high efficiency and convenience in the concentration and detection of foodborne pathogens. This article firstly reviews the bio-recognition elements integrated on microfluidic chips in recent years and the progress of microfluidic chip development for pathogen pretreatment. Furthermore, the research progress of microfluidic technology based on optical and electrochemical sensors for the detection of foodborne pathogenic bacteria is summarized and discussed. Finally, the future prospects for the application and challenges of microfluidic chips based on biosensors are presented.
Collapse
Affiliation(s)
- Fang Mi
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830017, China
- Department of Cuisine and Tourism, Xinjiang Bingtuan Xingxin Vocational and Technical College, Urumqi, 830074, China
| | - Cunming Hu
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830017, China
| | - Ying Wang
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830017, China
| | - Li Wang
- Department of Cuisine and Tourism, Xinjiang Bingtuan Xingxin Vocational and Technical College, Urumqi, 830074, China
| | - Fei Peng
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830017, China
| | - PengFei Geng
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830017, China
| | - Ming Guan
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830017, China.
| |
Collapse
|
5
|
Zhang Z, Zhao S, Jiang L, Wu J, Zhao W, Guo X, Peng N, Hu F. A sample-to-answer DNA detection microfluidic system integrating sample pretreatment and smartphone-readable gradient plasmonic photothermal continuous-flow PCR. Analyst 2022; 147:4876-4887. [DOI: 10.1039/d2an00908k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We report a microfluidic system integrating sample pretreatment and smartphone-readable gradient plasmonic photothermal continuous-flow PCR, paving the way for low-cost and rapid implementation of PCR diagnostics.
Collapse
Affiliation(s)
- Zengming Zhang
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
| | - Shuhao Zhao
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
| | - Lei Jiang
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
| | - Junjun Wu
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
| | - Wenhan Zhao
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
| | - Xiaoniu Guo
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
| | - Niancai Peng
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
| | - Fei Hu
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
| |
Collapse
|
6
|
Liu W, Yue F, Lee LP. Integrated Point-of-Care Molecular Diagnostic Devices for Infectious Diseases. Acc Chem Res 2021; 54:4107-4119. [PMID: 34699183 DOI: 10.1021/acs.accounts.1c00385] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The global outbreaks of deadly infectious diseases caused by pathogenic microorganisms have threatened public health worldwide and significantly motivated scientists to satisfy an urgent need for a rapid and accurate detection of pathogens. Traditionally, the culture-based technique is considered as the gold standard for pathogen detection, yet it has a long turnaround time due to the overnight culturing and pathogen isolation. Alternatively, nucleic acid amplification tests provide a relatively shorter turnaround time to identify whether pathogens exist in individuals with high sensitivity and high specificity. In most cases, nucleic acid amplification tests undergo three steps: sample preparation, nucleic acid amplification, and signal transduction. Despite the explosive advancement in nucleic acid amplification and signal transduction technologies, the complex and labor-intensive sample preparation steps remain a bottleneck to create a transformative integrated point-of-care (POC) molecular diagnostic device. Researchers have attempted to simplify and integrate the sample preparations for nucleic acid-based molecular diagnostic devices with innovative progress in integration strategies, engineered materials, reagent storages, and fluid actuation. Therefore, understanding the know-how and obtaining truthful knowledge of existing integrated POC molecular diagnostic devices comprising sample preparations, nucleic acid amplification, and signal transduction can generate innovative solutions to achieve personalized precision medicine and improve global health.In this Account, we discuss the challenges of automated sample preparation solutions integrated with nucleic acid amplification and signal transduction for rapid and precise home diagnostics. Blood, nasal swab, saliva, urine, and stool are emphasized as the most commonly used clinical samples for integrated POC molecular diagnostics of infectious diseases. Even though these five types of samples possess relatively correlated biomarkers due to the human body's circulatory system, each shows unique properties and exclusive advantages for molecular diagnostics in specific situations, which are included in this Account. We examine different integrated POC devices for sample preparation, which includes pathogen isolation and enrichment from the crude sample and nucleic acid purification from isolated pathogens. We present the promising on-chip integration approaches for nucleic acid amplification. We also investigate the on-chip integration methods for reagent storage, which is crucial to simplify the manual operation for end-users. Finally, we present several integrated POC molecular diagnostic devices for infectious diseases. The integrated sample preparation and nucleic acid amplification approach reviewed here can potentially impact the next generation of POC molecular home diagnostic chips, which will significantly impact public health, emergency medicine, and global biosecurity.
Collapse
Affiliation(s)
- Wenpeng Liu
- Renal Division and Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston 02115, Massachusetts, United States
| | - Fei Yue
- Renal Division and Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston 02115, Massachusetts, United States
| | - Luke P Lee
- Renal Division and Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston 02115, Massachusetts, United States
- Department of Bioengineering, Department of Electrical Engineering and Computer Science, University of California at Berkeley, Berkeley 94720, California, United States
- Institute of Quantum Biophysics, Department of Biophysics, Sungkyunkwan University, Suwon 16419, Korea
| |
Collapse
|
7
|
Trinh KTL, Le NXT, Lee NY. Chitosan-polydopamine hydrogel complex: a novel green adhesion agent for reversibly bonding thermoplastic microdevice and its application for cell-friendly microfluidic 3D cell culture. LAB ON A CHIP 2020; 20:3524-3534. [PMID: 32869048 DOI: 10.1039/d0lc00621a] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Owing to biocompatible characteristics and supporting cell growth capability, hydrogels have been widely used for scaffold fabrication and surface coating for cell culture. To employ the advantages of hydrogels, in the present study, we introduce a biocompatible chitosan (CS)-polydopamine (pDA) hydrogel complex as a green adhesion agent for the reversible bonding of thermoplastics assisted by UV irradiation. Poly(methyl methacrylate) (PMMA) substrates were bonded due to the covalent bond network formed between the amine groups of either CS or pDA in the hydrogel complex and the aldehyde groups of the oxidized PMMA surface via the Schiff-base reaction during the UV irradiation. Furthermore, the introduced method allowed for reversible bonding, which is highly appropriate for the fabrication of microdevices for cell-related applications. Surface characterizations such as water contact angle measurement, scanning electron microscopy analysis (SEM), atomic force microscopy analysis (AFM), and Fourier-transform infrared microscopy analysis (FTIR) were performed to confirm the successful coating of the hydrogel complex on the PMMA surface. Moreover, the bonding between two PMMAs or PMMA with other thermoplastics was successfully investigated with high bond strengths ranging from 0.4 to 0.7 MPa. The potential for reversible bonding of this method was verified by repeating the bonding/debonding cycle of the bonded PMMAs for three times, which maintained the bond strength at approximately 0.5 MPa. The compatibility of the bonding method in biological applications was examined by culturing mesenchymal stem cells (MSCs) inside a microchannel where multiple uniform-sized MSC spheroids were successfully formed. Then, spheroids were harvested for off-chip experiments enabled by the reversibility of the introduced bonding strategy. The bonding strategy employing a green hydrogel complex as a cell-friendly and eco-friendly adhesion agent could have a high impact on the fabrication of microdevices suitable for advanced organ-on-a-chip studies.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| | | | | |
Collapse
|
8
|
Trinh KT, Thai DA, Chae WR, Lee NY. Rapid Fabrication of Poly(methyl methacrylate) Devices for Lab-on-a-Chip Applications Using Acetic Acid and UV Treatment. ACS OMEGA 2020; 5:17396-17404. [PMID: 32715224 PMCID: PMC7377064 DOI: 10.1021/acsomega.0c01770] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 06/23/2020] [Indexed: 05/17/2023]
Abstract
In the present study, we introduce a new approach for rapid bonding of poly(methyl methacrylate) (PMMA)-based microdevices using an acetic acid solvent with the assistance of UV irradiation. For the anticipated mechanism, acetic acid and UV irradiation induced free radicals on the PMMA surfaces, and acrylate monomers subsequently formed cross-links to create a permanent bonding between the PMMA substrates. PMMA devices effectively bonded within 30 s at a low pressure using clamps, and a clogging-free microchannel was achieved with the optimized 50% acetic acid. For surface characterizations, contact angle measurements and bonding performance analyses were conducted using predetermined acetic acid concentrations to optimize bonding conditions. In addition, the highest bond strength of bonded PMMA was approximately 11.75 MPa, which has not been reported before in the bonding of PMMA. A leak test was performed over 180 h to assess the robustness of the proposed method. Moreover, to promote the applicability of this bonding method, we tested two kinds of microfluidic device applications, including a cell culture-based device and a metal microelectrode-integrated device. The results showed that the cell culture-based application was highly biocompatible with the PMMA microdevices fabricated using an acetic acid solvent. Moreover, the low pressure required during the bonding process supported the integration of metal microelectrodes with the PMMA microdevice without any damage to the metal films. This novel bonding method holds great potential in the ecofriendly and rapid fabrication of microfluidic devices using PMMA.
Collapse
Affiliation(s)
- Kieu The
Loan Trinh
- Department
of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| | - Duc Anh Thai
- Department
of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| | - Woo Ri Chae
- BioNano
Research Institute, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| | - Nae Yoon Lee
- Department
of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| |
Collapse
|
9
|
Yoo HJ, Baek C, Lee MH, Min J. Integrated microsystems for the in situ genetic detection of dengue virus in whole blood using direct sample preparation and isothermal amplification. Analyst 2020; 145:2405-2411. [PMID: 32053125 DOI: 10.1039/c9an02435b] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Owing to the frequent outbreak of dengue fever worldwide, a highly sensitive but in situ simple process diagnostic device is required to detect the dengue virus. However, the current immune affinity-based methods have sensitivity issues and nucleic acid-based diagnostic devices have not been suitable for field diagnosis due to the complexity in sample preparation. Here, a simple and fast nucleic acid-based diagnostic tool to directly detect dengue viruses in whole blood is demonstrated using a microbead-assisted direct sample preparation buffer (MB-buffer) and isothermal amplification (loop-mediated isothermal amplification, LAMP). To maximize the performance of the sample preparation process in the microfluidic chip platform, the chemical composition of the sample preparation buffer is simplified and combined with physical tools (heating and bead beating). The entire serial processes consisted of only (1) sample (whole blood) loading, (2) stirring for 90 s, (3) heating at 70 °C for 10 min, and (4) LAMP amplification in the simply designed microfluidic chip cartridge. A single syringe was utilized for sample loading and microfluidic solution transfer. Consequently, dengue viruses were qualitatively detected and discriminated with high sensitivity (LOD: 102 PFU per 200 μL of whole blood) in less than 1 hour without the use of any sophisticated system.
Collapse
Affiliation(s)
- Hyun Jin Yoo
- School of Integrative Engineering, Chung-Ang University, Heukseok-dong, Dongjak-gu, Seoul, 06974, South Korea.
| | | | | | | |
Collapse
|
10
|
A Novel Microfluidic Device Integrated with Chitosan-Modified Capillaries for Rapid ZIKV Detection. MICROMACHINES 2020; 11:mi11020186. [PMID: 32054007 PMCID: PMC7074674 DOI: 10.3390/mi11020186] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 01/29/2020] [Accepted: 02/03/2020] [Indexed: 02/08/2023]
Abstract
The outbreak of Zika virus (ZIKV) has posed a great challenge to public health in recent years. To address the urgent need of ZIKV RNA assays, we integrate the microfluidic chip embedded with chitosan-modified silicon dioxide capillaries, smartphone-based detection unit to be a C3-system for the rapid extraction and detection of ZIKV RNA. The C3-system is characterized by: (1) four chitosan-modified silicon dioxide capillaries integrated in the microfluidic chip for target ZIKV RNA enrichment and “in situ PCR” (polymerase chain reaction) amplification; (2) smartphone-based point of care (POC) device consisting of a pneumatic subsystem for controlling the nucleic acid extraction processes in the microfluidic chip, a heating subsystem for sample lysis and PCR amplification, and an optical subsystem for signal acquisition. The entire detection processes including sample lysis, ZIKV RNA enrichment, and reverse-transcription polymerase chain reaction (RT-PCR) is achieved in the microfluidic chip. Moreover, PCR buffers can be directly loaded into the chitosan-modified silicon dioxide capillaries for “in situ PCR”, in which the captured ZIKV RNA is directly used for downstream PCR without any loss. ZIKV RNA extracted by the C3-system can be successfully recovered at very low concentrations of 50 transducing units (TU)/mL from crude human saliva. This means that our method of detecting viremia in patients infected with ZIKV is reliable.
Collapse
|
11
|
Chuang CS, Wu CY, Juan PH, Hou NC, Fan YJ, Wei PK, Sheen HJ. LMP1 gene detection using a capped gold nanowire array surface plasmon resonance sensor in a microfluidic chip. Analyst 2020; 145:52-60. [DOI: 10.1039/c9an01419e] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
A new detection device by using SPR nanowire array chip and a microfluidics system was developed. A simple, low-cost and reproducible SPR nanowire chip with a visible light source displayed real-time detection capability.
Collapse
Affiliation(s)
- Chih-Shen Chuang
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
- School of Biomedical Engineering
| | - Chieh-Ying Wu
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
| | - Po-Han Juan
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
| | - Nai-Cheng Hou
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
| | - Yu-Jui Fan
- School of Biomedical Engineering
- Taipei Medical University
- Taipei 11031
- Taiwan
- International PhD Program for Biomedical Engineering
| | - Pei-Kuen Wei
- Research Center for Applied Sciences
- Academia Sinica
- Taipei 11529
- Taiwan
| | - Horn-Jiunn Sheen
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
| |
Collapse
|
12
|
Fabrication of a polycarbonate microdevice and boronic acid-mediated surface modification for on-chip sample purification and amplification of foodborne pathogens. Biomed Microdevices 2019; 21:72. [PMID: 31286242 DOI: 10.1007/s10544-019-0420-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
In this study, we integrated sample purification and genetic amplification in a seamless polycarbonate microdevice to facilitate foodborne pathogen detection. The sample purification process was realized based on the increased affinity of the boronic acid-modified surface toward the cis-diol group present on the bacterial outer membrane. The modification procedure was conducted at room temperature using disposable syringe. The visible color and fluorescence signals of alizarin red sodium were used to confirm the success of the surface modification process. Escherichia coli O157:H7 containing green fluorescence protein (GFP) and Staphylococcus aureus were chosen as the microbial models to demonstrate the nonspecific immobilization using the microdevice. Bacterial solutions of various concentrations were injected into the microdevice at three flow rates to optimize the operation conditions. This microdevice successfully amplified the 384-bp fragment of the eaeA gene of the captured E. coli O157:H7 within 1 h. Its detection limit for E. coli O157:H7 was determined to be 1 × 103 colony-forming units per milliliter (CFU mL-1). The proposed microdevice serves as a monolithic platform for facile and on-site identification of major foodborne pathogens.
Collapse
|
13
|
Fully integrated and slidable paper-embedded plastic microdevice for point-of-care testing of multiple foodborne pathogens. Biosens Bioelectron 2019; 135:120-128. [PMID: 31004922 DOI: 10.1016/j.bios.2019.04.011] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 04/03/2019] [Accepted: 04/05/2019] [Indexed: 12/27/2022]
Abstract
This study presents a slidable paper-embedded plastic microdevice fully integrated with DNA extraction, loop-mediated isothermal amplification (LAMP), and colorimetric detection functionalities. The developed microdevice consists of three layers that allow a sliding movement to mix the sample and reagents for DNA purification, amplification, and detection in a sequential manner. An FTA card was employed in the main chamber for DNA extraction and purification from intact bacterial cells. Subsequently, LAMP reagents and fuchsin-stored chambers were pulled toward the main chambers for DNA amplifications at 65 °C. After 30 min, the detection reagents-stored chambers were then moved to main chambers for result analysis. For the detection of LAMP amplicons, a novel colorimetric fuchsin-based method was employed. The wide applicability of the integrated microdevice was demonstrated by successfully screening three major foodborne pathogens, namely Salmonella spp., Staphylococcus aureus, and Escherichia coli O157:H7 in food, enabling highly sensitive detection of 3.0 × 101 CFU/sample of Gram-negative bacteria (Salmonella spp. and Escherichia coli O157:H7) and 3.0 × 102 CFU/sample of Gram-positive bacteria (Staphylococcus aureus) within 75 min. The portable and integrated microdevice presented in this study holds significant promise for point-of-care applications to accurately and rapidly diagnose and control diseases.
Collapse
|
14
|
Trinh TND, Lee NY. A foldable isothermal amplification microdevice for fuchsin-based colorimetric detection of multiple foodborne pathogens. LAB ON A CHIP 2019; 19:1397-1405. [PMID: 30847458 DOI: 10.1039/c8lc01389f] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
In this study, we have developed a foldable microdevice fully integrating DNA purification, amplification, and detection processes for detecting multiple foodborne pathogens. Specifically, the loop-mediated isothermal amplification (LAMP) technique was combined with a fuchsin-based direct DNA colorimetric detection method. The microdevice was composed of three parts: a sample zone, reaction zone, and detection zone. A sealing film attached to the sample, reaction, and detection zones served as a bottom layer to make the microdevice foldable. The detection zone was made up of paper strips attached to the sticky side of the sealing film, and fuchsin-stained lines were drawn on the paper strips. The microdevice can be folded to directly transfer the DNA template solution from the sample chambers to the reaction chambers. In this manner, fluid manipulation was readily realized and the use of a bulky instrument such as a pump or rotator was completely dispensed with. After the LAMP reaction, the detection zone was folded so that the fuchsin-stained lines were completely soaked into the reaction chambers. Genomic DNAs of Salmonella spp. and Escherichia coli O157:H7 were first successfully purified from thermally-lysed milk using polydopamine-coated paper, amplified by LAMP, and directly identified by the naked eye using fuchsin within 65 min. Using this microdevice, approximately 102 CFU per mL of Salmonella spp. was detected. These results indicate the significant potential of this microdevice for the sample-in-answer-out genetic analysis of multiple foodborne pathogens in resource-limited environments.
Collapse
Affiliation(s)
- Thi Ngoc Diep Trinh
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea.
| | | |
Collapse
|