1
|
Warren CG, Dasgupta PK. Liquid phase detection in the miniature scale. Microfluidic and capillary scale measurement and separation systems. A tutorial review. Anal Chim Acta 2024; 1305:342507. [PMID: 38677834 DOI: 10.1016/j.aca.2024.342507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/29/2024]
Abstract
Microfluidic and capillary devices are increasingly being used in analytical applications while their overall size keeps decreasing. Detection sensitivity for these microdevices gains more importance as device sizes and consequently, sample volumes, decrease. This paper reviews optical, electrochemical, electrical, and mass spectrometric detection methods that are applicable to capillary scale and microfluidic devices, with brief introduction to the principles in each case. Much of this is considered in the context of separations. We do consider theoretical aspects of separations by open tubular liquid chromatography, arguably the most potentially fertile area of separations that has been left fallow largely because of lack of scale-appropriate detection methods. We also examine the theoretical basis of zone electrophoretic separations. Optical detection methods discussed include UV/Vis absorbance, fluorescence, chemiluminescence and refractometry. Amperometry is essentially the only electrochemical detection method used in microsystems. Suppressed conductance and especially contactless conductivity (admittance) detection are in wide use for the detection of ionic analytes. Microfluidic devices, integrated to various mass spectrometers, including ESI-MS, APCI-MS, and MALDI-MS are discussed. We consider the advantages and disadvantages of each detection method and compare the best reported limits of detection in as uniform a format as the available information allows. While this review pays more attention to recent developments, our primary focus has been on the novelty and ingenuity of the approach, regardless of when it was first proposed, as long as it can be potentially relevant to miniature platforms.
Collapse
Affiliation(s)
- Cable G Warren
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States
| | - Purnendu K Dasgupta
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States.
| |
Collapse
|
2
|
Zheng J, Huang R, Lin Z, Chen S, Yuan K. Nano/Micromotors for Cancer Diagnosis and Therapy: Innovative Designs to Improve Biocompatibility. Pharmaceutics 2023; 16:44. [PMID: 38258055 PMCID: PMC10821023 DOI: 10.3390/pharmaceutics16010044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 12/18/2023] [Accepted: 12/21/2023] [Indexed: 01/24/2024] Open
Abstract
Nano/micromotors are artificial robots at the nano/microscale that are capable of transforming energy into mechanical movement. In cancer diagnosis or therapy, such "tiny robots" show great promise for targeted drug delivery, cell removal/killing, and even related biomarker sensing. Yet biocompatibility is still the most critical challenge that restricts such techniques from transitioning from the laboratory to clinical applications. In this review, we emphasize the biocompatibility aspect of nano/micromotors to show the great efforts made by researchers to promote their clinical application, mainly including non-toxic fuel propulsion (inorganic catalysts, enzyme, etc.), bio-hybrid designs, ultrasound propulsion, light-triggered propulsion, magnetic propulsion, dual propulsion, and, in particular, the cooperative swarm-based strategy for increasing therapeutic effects. Future challenges in translating nano/micromotors into real applications and the potential directions for increasing biocompatibility are also described.
Collapse
Affiliation(s)
- Jiahuan Zheng
- Department of Chemistry, Shantou University Medical College, Shantou 515041, China;
| | - Rui Huang
- Bio-Analytical Laboratory, Shantou University Medical College, Shantou 515041, China; (R.H.); (Z.L.)
| | - Zhexuan Lin
- Bio-Analytical Laboratory, Shantou University Medical College, Shantou 515041, China; (R.H.); (Z.L.)
| | - Shaoqi Chen
- Department of Ultrasound, First Affiliated Hospital of Shantou University Medical College, Shantou 515041, China
| | - Kaisong Yuan
- Bio-Analytical Laboratory, Shantou University Medical College, Shantou 515041, China; (R.H.); (Z.L.)
- Department of Ultrasound, First Affiliated Hospital of Shantou University Medical College, Shantou 515041, China
| |
Collapse
|
3
|
Li Z, Lowe JP, Fletcher PJ, Carta M, McKeown NB, Marken F. Tuning and Coupling Irreversible Electroosmotic Water Flow in Ionic Diodes: Methylation of an Intrinsically Microporous Polyamine (PIM-EA-TB). ACS APPLIED MATERIALS & INTERFACES 2023; 15:42369-42377. [PMID: 37638824 PMCID: PMC10510042 DOI: 10.1021/acsami.3c10220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 08/17/2023] [Indexed: 08/29/2023]
Abstract
Molecularly rigid polymers with internal charges (positive charges induced by amine methylation) allow electroosmotic water flow to be tuned by adjusting the charge density (the degree of methylation). Here, a microporous polyamine (PIM-EA-TB) is methylated to give a molecularly rigid anion conductor. The electroosmotic drag coefficient (the number of water molecules transported per anion) is shown to increase with a lower degree of methylation. Net water transport (without charge flow) in a coupled anionic diode circuit is demonstrated based on combining low and high electroosmotic drag coefficient materials. The AC-electricity-driven net process offers water transport (or transport of other neutral species, e.g., drugs) with net zero ion transport and without driver electrode side reactions.
Collapse
Affiliation(s)
- Zhongkai Li
- Department
of Chemistry, University of Bath, Claverton Down, Bath BA2 7AY, U.K.
| | - John P. Lowe
- Materials
& Chemistry Characterisation Facility, MC, University of Bath, Bath BA2 7AY, U.K.
| | - Philip J. Fletcher
- Materials
& Chemistry Characterisation Facility, MC, University of Bath, Bath BA2 7AY, U.K.
| | - Mariolino Carta
- Department
of Chemistry, Swansea University, College
of Science, Grove Building, Singleton Park, Swansea SA2 8PP, U.K.
| | - Neil B. McKeown
- EaStCHEM
School of Chemistry, University of Edinburgh,
Joseph Black Building, David Brewster Road, Edinburgh, Scotland EH9 3JF, U.K.
| | - Frank Marken
- Department
of Chemistry, University of Bath, Claverton Down, Bath BA2 7AY, U.K.
| |
Collapse
|
4
|
Medina DAV, Cardoso AT, Borsatto JVB, Lanças FM. Open tubular liquid chromatography: Recent advances and future trends. J Sep Sci 2023; 46:e2300373. [PMID: 37582640 DOI: 10.1002/jssc.202300373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 07/28/2023] [Accepted: 07/31/2023] [Indexed: 08/17/2023]
Abstract
Nano-liquid chromatography (nanoLC) is gaining significant attention as a primary analytical technique across various scientific domains. Unlike conventional high-performance LC, nanoLC utilizes columns with inner diameters (i.ds.) usually ranging from 10 to 150 μm and operates at mobile phase flow rates between 10 and 1000 nl/min, offering improved chromatographic performance and detectability. Currently, most exploration of nanoLC has focused on particle-packed columns. Although open tubular LC (OTLC) can provide superior performance, optimized OTLC columns require very narrow i.ds. (< 10 μm) and demand challenging instrumentation. At the moment, these challenges have limited the success of OTLC. Nevertheless, remarkable progress has been made in developing and utilizing OTLC systems featuring narrow columns (< 2 μm). Additionally, significant efforts have been made to explore larger columns (10-75 μm i.d), demonstrating practical applicability in many situations. Due to their perceived advantages, interest in OTLC has resurged in the last two decades. This review provides an updated outlook on the latest developments in OTLC, focusing on instrumental challenges, achievements, and advancements in column technology. Moreover, it outlines selected applications that illustrate the potential of OTLC for performing targeted and untargeted studies.
Collapse
Affiliation(s)
- Deyber Arley Vargas Medina
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - Alessandra Timoteo Cardoso
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - João Victor Basolli Borsatto
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - Fernando Mauro Lanças
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| |
Collapse
|
5
|
Diehm J, Ballweg T, Franzreb M. Development of a 3D Printed Micro Simulated Moving Bed Chromatography System. J Chromatogr A 2023; 1695:463928. [PMID: 36966603 DOI: 10.1016/j.chroma.2023.463928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 03/01/2023] [Accepted: 03/13/2023] [Indexed: 03/17/2023]
Abstract
In the 1960s, chromatography processes were revolutionized by the invention of simulated moving bed chromatography. This method not only enhances the separation performance and resin utilization in comparison to batch-chromatography, it has also a much lower buffer consumption. While simulated moving bed chromatography nowadays is applied for a wide range of industrial applications, it was never transferred to the micro-scale (in regards to column and system volume). In our opinion a micro simulated moving bed chromatography system (µSMB) would be a useful tool for many applications, ranging from early process development and long term studies to downstream processing of speciality products. We implemented such a µSMB with a 3D printed central rotary valve and a microfluidic flow controller as flow source. We tested the system with a four zone open loop setup for the separation of bovine serum albumin and ammonium sulfate with size exclusion chromatography. We used four process points and could achieve desalting levels of BSA ranging from 94% to 99%, with yields ranging form 65% to 88%. Thus, we were able to achieve comparable results to common lab scale processes. With a total dead volume of 358 µL, including all sensors, connections and the valve, this is, to the best of our knowledge, the smallest SMB system that was ever built and we were able to perform experiments with feed flow rates reaching as low as 15 µL/min.
Collapse
|
6
|
Silverio V, Canane PAG, Martins TA, Afonso R, Cardoso S, Batista E. Development of a microfluidic electroosmosis pump on a chip for steady and continuous fluid delivery. BIOMED ENG-BIOMED TE 2023; 68:79-90. [PMID: 36525637 DOI: 10.1515/bmt-2022-0051] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 11/24/2022] [Indexed: 12/23/2022]
Abstract
Infusion therapy is the most common form of therapy used in health care. However, the existing infusion devices show higher flow discrepancies as flow rates decrease to a few nL min-1. As a result, dosing errors can contribute to the morbidity and mortality of patients. In the scope of project 18HLT08 MeDD II - Metrology for drug delivery, this investigation aims at the development of a silicon microchip flow pump capable of steadily and continuously dispense very low flow rates of a few nL min-1. The fabrication methodologies explored here use a combination of typical cleanroom micro/nanofabrication techniques and off-the-shelf equipment. Preliminary tests show flow rates as low as 45 nL min-1 can be obtained in this microfluidic electroosmotic pump. The experimental flow rates are in good agreement with results predicted by multiphysics simulation, with less than 8% deviation ratio. This cost effective electroosmotic micropump has the potential to act as a steady and continuous drug delivery system to neonatal patients as well as to organs on chip (OoC), determining the stability of the shear stress imposed on the cells or the right cell culture medium conditions.
Collapse
Affiliation(s)
- Vania Silverio
- INESC MN Microsistemas e Nanotecnologias and Department of Physics, Instituto Superior Tecnico, Universidade de Lisboa, Lisbon, Portugal
| | | | | | - Ruben Afonso
- INESC MN Microsistemas e Nanotecnologias, Lisbon, Portugal
| | - Susana Cardoso
- INESC MN Microsistemas e Nanotecnologias and Department of Physics, Instituto Superior Tecnico, Universidade de Lisboa, Lisbon, Portugal
| | | |
Collapse
|
7
|
Kare SS, Ramkumar PK, Gao Y, Xu J, Finan JD. Connected Droplet Shape Analysis for Nanoflow Quantification in Thin Electroosmotic Micropumps and a Tunable Convex Lens Application. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:2569-2578. [PMID: 36763988 PMCID: PMC9949215 DOI: 10.1021/acs.langmuir.2c02875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 01/30/2023] [Indexed: 06/18/2023]
Abstract
Thin electroosmotic flow (EOF) micropumps can generate flow in confined spaces such as lab-on-a-chip microsystems and implantable drug delivery devices. However, status quo methods for quantifying flow and other important parameters in EOF micropumps depend on microfluidic interconnects or fluorescent particle tracking: methods that can be complex and error-prone. Here, we present a novel connected droplet shape analysis (CDSA) technique that simplifies flow rate and zeta potential quantification in thin EOF micropumps. We also show that a pair of droplets connected by an EOF pump can function as a tunable convex lens system (TCLS). We developed a biocompatible and all polymer EOF micropump with an SU-8 substrate and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) electrodes. We microdrilled a channel through the electrode/SU-8/electrode layers to realize a monolithic EOF micropump. Then, we deposited a pinned droplet on each end of the microchannel so that it connected them. By controlling the EOF between the droplets and measuring the corresponding change in their shape, we quantified the nanoliter EOF rate and zeta potential at the interface of SU-8 with two liquids (deionized water and a l-glutamate neurotransmitter solution). When the droplet pair and pump were used as a TCLS, CDSA successfully predicted how the focal length would change when the pump drove fluid from one droplet to another. In summary, CDSA is a simple low-cost technique for EOF rate and zeta potential measurement, and a pair of droplets connected by an EOF micropump can function as a TCLS without any moving parts.
Collapse
Affiliation(s)
- Sai Siva Kare
- Department of Mechanical and Industrial
Engineering, University of Illinois at Chicago, Chicago, Illinois 60607, United States
| | - Pradeep Kumar Ramkumar
- Department of Mechanical and Industrial
Engineering, University of Illinois at Chicago, Chicago, Illinois 60607, United States
| | - Yuan Gao
- Department of Mechanical and Industrial
Engineering, University of Illinois at Chicago, Chicago, Illinois 60607, United States
| | - Jie Xu
- Department of Mechanical and Industrial
Engineering, University of Illinois at Chicago, Chicago, Illinois 60607, United States
| | - John Desmond Finan
- Department of Mechanical and Industrial
Engineering, University of Illinois at Chicago, Chicago, Illinois 60607, United States
| |
Collapse
|
8
|
Dos-Reis-Delgado AA, Carmona-Dominguez A, Sosa-Avalos G, Jimenez-Saaib IH, Villegas-Cantu KE, Gallo-Villanueva RC, Perez-Gonzalez VH. Recent advances and challenges in temperature monitoring and control in microfluidic devices. Electrophoresis 2023; 44:268-297. [PMID: 36205631 PMCID: PMC10092670 DOI: 10.1002/elps.202200162] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 09/22/2022] [Accepted: 10/03/2022] [Indexed: 11/07/2022]
Abstract
Temperature is a critical-yet sometimes overlooked-parameter in microfluidics. Microfluidic devices can experience heating inside their channels during operation due to underlying physicochemical phenomena occurring therein. Such heating, whether required or not, must be monitored to ensure adequate device operation. Therefore, different techniques have been developed to measure and control temperature in microfluidic devices. In this contribution, the operating principles and applications of these techniques are reviewed. Temperature-monitoring instruments revised herein include thermocouples, thermistors, and custom-built temperature sensors. Of these, thermocouples exhibit the widest operating range; thermistors feature the highest accuracy; and custom-built temperature sensors demonstrate the best transduction. On the other hand, temperature control methods can be classified as external- or integrated-methods. Within the external methods, microheaters are shown to be the most adequate when working with biological samples, whereas Peltier elements are most useful in applications that require the development of temperature gradients. In contrast, integrated methods are based on chemical and physical properties, structural arrangements, which are characterized by their low fabrication cost and a wide range of applications. The potential integration of these platforms with the Internet of Things technology is discussed as a potential new trend in the field.
Collapse
Affiliation(s)
| | | | - Gerardo Sosa-Avalos
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Nuevo, León, Mexico
| | - Ivan H Jimenez-Saaib
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Nuevo, León, Mexico
| | - Karen E Villegas-Cantu
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Nuevo, León, Mexico
| | | | - Víctor H Perez-Gonzalez
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Nuevo, León, Mexico
| |
Collapse
|
9
|
Ko J, Kim C, Kim D, Song Y, Lee S, Yeom B, Huh J, Han S, Kang D, Koh JS, Cho J. High-performance electrified hydrogel actuators based on wrinkled nanomembrane electrodes for untethered insect-scale soft aquabots. Sci Robot 2022; 7:eabo6463. [DOI: 10.1126/scirobotics.abo6463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Hydrogels have diverse chemical properties and can exhibit reversibly large mechanical deformations in response to external stimuli; these characteristics suggest that hydrogels are promising materials for soft robots. However, reported actuators based on hydrogels generally suffer from slow response speed and/or poor controllability due to intrinsic material limitations and electrode fabrication technologies. Here, we report a hydrogel actuator that operates at low voltages (<3 volts) with high performance (strain > 50%, energy density > 7 × 10
5
joules per cubic meter, and power density > 3 × 10
4
watts per cubic meter), surpassing existing hydrogel actuators and other types of electroactive soft actuators. The enhanced performance of our actuator is due to the formation of wrinkled nanomembrane electrodes that exhibit high conductivity and excellent mechanical deformation through capillary-assisted assembly of metal nanoparticles and deswelling-induced wrinkled structures. By applying an electric potential through the wrinkled nanomembrane electrodes that sandwich the hydrogel, we were able to trigger a reversible and substantial electroosmotic water flow inside a hydrogel film, which drove the controlled swelling of the hydrogel. The high energy efficiency and power density of our wrinkled nanomembrane electrode–induced actuator enabled the fabrication of an untethered insect-scale aquabot integrated with an on-board control unit demonstrating maneuverability with fast locomotion speed (1.02 body length per second), which occupies only 2% of the total mass of the robot.
Collapse
Affiliation(s)
- Jongkuk Ko
- Department of Chemical and Biological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Changhwan Kim
- Department of Mechanical Engineering, Ajou University, 206 Worldcup-ro, Yeongtong-gu, Suwon 16499, Republic of Korea
| | - Dongjin Kim
- Department of Mechanical Engineering, Ajou University, 206 Worldcup-ro, Yeongtong-gu, Suwon 16499, Republic of Korea
| | - Yongkwon Song
- Department of Chemical and Biological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Seokmin Lee
- Department of Chemical and Biological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Bongjun Yeom
- Department of Chemical Engineering, Hanyang University, Seongdong-gu, Seoul 04763, Republic of Korea
| | - June Huh
- Department of Chemical and Biological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
- Department of Life Sciences, Korea University, Seoul 02841, Republic of Korea
| | - Seungyong Han
- Department of Mechanical Engineering, Ajou University, 206 Worldcup-ro, Yeongtong-gu, Suwon 16499, Republic of Korea
| | - Daeshik Kang
- Department of Mechanical Engineering, Ajou University, 206 Worldcup-ro, Yeongtong-gu, Suwon 16499, Republic of Korea
| | - Je-Sung Koh
- Department of Mechanical Engineering, Ajou University, 206 Worldcup-ro, Yeongtong-gu, Suwon 16499, Republic of Korea
| | - Jinhan Cho
- Department of Chemical and Biological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
- KU-KIST Graduate School of Converging Science and Technology, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| |
Collapse
|
10
|
Ladiges DR, Wang JG, Srivastava I, Nonaka A, Bell JB, Carney SP, Garcia AL, Donev A. Modeling electrokinetic flows with the discrete ion stochastic continuum overdamped solvent algorithm. Phys Rev E 2022; 106:035104. [PMID: 36266814 DOI: 10.1103/physreve.106.035104] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 08/09/2022] [Indexed: 06/16/2023]
Abstract
In this article we develop an algorithm for the efficient simulation of electrolytes in the presence of physical boundaries. In previous work the discrete ion stochastic continuum overdamped solvent (DISCOS) algorithm was derived for triply periodic domains, and was validated through ion-ion pair correlation functions and Debye-Hückel-Onsager theory for conductivity, including the Wien effect for strong electric fields. In extending this approach to include an accurate treatment of physical boundaries we must address several important issues. First, the modifications to the spreading and interpolation operators necessary to incorporate interactions of the ions with the boundary are described. Next we discuss the modifications to the electrostatic solver to handle the influence of charges near either a fixed potential or dielectric boundary. An additional short-ranged potential is also introduced to represent interaction of the ions with a solid wall. Finally, the dry diffusion term is modified to account for the reduced mobility of ions near a boundary, which introduces an additional stochastic drift correction. Several validation tests are presented confirming the correct equilibrium distribution of ions in a channel. Additionally, the methodology is demonstrated using electro-osmosis and induced-charge electro-osmosis, with comparison made to theory and other numerical methods. Notably, the DISCOS approach achieves greater accuracy than a continuum electrostatic simulation method. We also examine the effect of under-resolving hydrodynamic effects using a "dry diffusion" approach, and find that considerable computational speedup can be achieved with a negligible impact on accuracy.
Collapse
Affiliation(s)
- D R Ladiges
- Center for Computational Sciences and Engineering, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - J G Wang
- Center for Computational Sciences and Engineering, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - I Srivastava
- Center for Computational Sciences and Engineering, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - A Nonaka
- Center for Computational Sciences and Engineering, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - J B Bell
- Center for Computational Sciences and Engineering, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - S P Carney
- Department of Mathematics, University of California, Los Angeles, Los Angeles, California 90095, USA
| | - A L Garcia
- Department of Physics and Astronomy, San Jose State University, San Jose, California 95192, USA
| | - A Donev
- Courant Institute of Mathematical Sciences, New York University, New York, New York 10012, USA
| |
Collapse
|
11
|
Chen A, Liu S. Open Tubular Liquid Chromatographic System for Using Columns with Inner Diameter of 2 µm. A Tutorial. J Chromatogr A 2022; 1673:463202. [DOI: 10.1016/j.chroma.2022.463202] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 05/25/2022] [Accepted: 06/05/2022] [Indexed: 02/01/2023]
|
12
|
Nano-labeled materials as detection tags for signal amplification in immunochromatographic assay. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116673] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
13
|
Modeling, Kinematic Characteristics Analysis and Experimental Testing of an Elliptical Rotor Scraper Pump. MACHINES 2022. [DOI: 10.3390/machines10020078] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Against the backdrop of the rapid burgeoning of international energy engineering, the efficient utilization of energy is a paramount factor. The key idea in this paper is to propose an elliptical rotor scraper pump (ERSP) in order to address the imperfections and defects of traditional volume pumps, such as their labyrinthine design, low volume utilization efficiency and undesirable sealing performance. The ERSP can dramatically achieve the aims of ameliorating pump structure and improving energy efficiency. One of the Roots pump's rotors or the vane pump's shifting blade is replaced by a swing scraper in the ERSP. It is worth noting that a small swing range is a high-priority feature of the scraper; the scraper not only serves the purpose of dividing the pump cavity and self-sealing the unit but also reduces the noise level when working. A vital function of ERSP is the efficient conversion of mechanical energy into fluid pressure energy by changing the volume. Simultaneously, based on theoretical analysis, the mathematical model of the ERSP is established, and its kinematic characteristics are investigated, using ADAMS to verify the kinematic rationality of the ERSP. Ultimately, the research group manufactured a prototype of the pump, based on the previous simulation results and calculations, and experiments verified the feasibility of the pump. The design and research of the ERSP have essential reference significance for the development of fluid energy machinery technology.
Collapse
|
14
|
Zhou Y, Guo G, Wang X. Development of
Ultranarrow‐Bore
Open Tubular High Efficiency Liquid Chromatography. CHINESE J CHEM 2022. [DOI: 10.1002/cjoc.202100445] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Yingyan Zhou
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Guangsheng Guo
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Xiayan Wang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| |
Collapse
|
15
|
Riad A, Khorshidi B, Mansouri A, Sadrzadeh M. Transient electroosmotic-driven ionic current magnetic fields in a charged nano-capillary. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.127374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
16
|
Guo P, Qian F, Zhang W, Yan H, Wang Q, Zhao C. Radial basis function interpolation supplemented lattice Boltzmann method for electroosmotic flows in microchannel. Electrophoresis 2021; 42:2171-2181. [PMID: 34549443 DOI: 10.1002/elps.202100155] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 08/24/2021] [Accepted: 09/09/2021] [Indexed: 01/19/2023]
Abstract
Large gradients of physical variables near the channel walls are characteristic of EOF. The previous numerical simulations of EOFs with the lattice Boltzmann method (LBM) utilize uniform lattice and are not efficient, especially when the electric double layer (EDL) thickness is significantly smaller than the channel height. The efficient LBM simulation of EOF in microchannel calls for a nonuniform mesh which is dense in the EDL region and sparse in the bulk region. In this article, we formulate a radial basis function (RBF)-based interpolation supplemented LBM (ISLBM) to solve the governing equations of EOF, that is, the Poisson, Nernst-Planck, and Navier-Stokes equations, in a nonuniform mesh system. Unlike the conventional ISLBM, the RBF-ISLBM determines the prestreaming distribution functions by using the local RBF-based interpolation over circular supporting regions and is particularly suitable for nonuniform meshes. The RBF-ISLBM is validated by the EOFs in infinitely long and finitely long microchannels. The results show that the RBF-ISLBM possesses excellent robustness and accuracy. Finally, we use the RBF-ISLBM to simulate the EOFs with the hitherto highest electrokinetic parameter, κa, defined by the ratio of channel height a to EDL thickness κ-1 , in LBM simulations of EOF.
Collapse
Affiliation(s)
- Panpan Guo
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, P. R. China
| | - Fang Qian
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, P. R. China
| | - Wenyao Zhang
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, P. R. China
| | - Huilong Yan
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, P. R. China
| | - Qiuwang Wang
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, P. R. China
| | - Cunlu Zhao
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, P. R. China
| |
Collapse
|
17
|
[Research advances in nano liquid chromatography instrumentation]. Se Pu 2021; 39:1065-1076. [PMID: 34505428 PMCID: PMC9404240 DOI: 10.3724/sp.j.1123.2021.06017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
小型化是液相色谱分离技术发展的重要趋势之一,包括仪器外形尺寸的小型化、分离材料粒径的小型化以及色谱柱内径的小型化。色谱柱内径的减小能够降低样品和流动相的消耗,具有更高的质量灵敏度,特别适合用于复杂样品体系的分离分析。纳升液相色谱一般是指使用内径小于100 μm的毛细管色谱柱,流速范围在每分钟几十至几百纳升的色谱技术。由于流速很低,色谱柱体积很小,柱外效应显著,因此对色谱仪器系统各个模块的性能以及系统柱外效应的优化提出了较高的要求。纳升液相色谱的输液装置需要能够准确稳定地输送纳升级流速,具有梯度输液模式,且拥有一定的耐压能力,以适应不同规格的色谱柱类型;进样装置需要能够进行准确重复的进样过程,进样体积及进样方式适合毛细管色谱柱,同时不产生明显的柱外效应;检测装置需要具有较高的灵敏度,且具有较小的柱外扩散;管路与连接系统需要稳定、可靠、易操作,并能够最大限度地减小柱外体积,适配纳升级流速。鉴于目前大多数纳升液相色谱系统与质谱检测器联用,因而本文主要从输液装置、进样装置、管路与连接3个方面对相关技术领域的研究论文、技术专利以及仪器厂商的宣传文件等进行了检索与归纳,综述了这些模块的技术路线与研究进展,同时简要介绍光学吸收型检测装置的优化思路与研究进展,并对部分商品化的纳升液相色谱系统进行了对比。
Collapse
|
18
|
Sun J, Zhang L, Li Z, Tang Q, Chen J, Huang Y, Hu C, Guo H, Peng Y, Wang ZL. A Mobile and Self-Powered Micro-Flow Pump Based on Triboelectricity Driven Electroosmosis. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2102765. [PMID: 34270820 DOI: 10.1002/adma.202102765] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 05/19/2021] [Indexed: 05/15/2023]
Abstract
Electroosmotic pumps have been widely used in microfluidic systems. However, traditional high-voltage (HV)-sources are bulky in size and induce numerous accessional reactions, which largely reduce the system's portability and efficiency. Herein, a motion-controlled, highly efficient micro-flow pump based on triboelectricity driven electroosmosis is reported. Utilizing the triboelectric nanogenerator (TENG), a strong electric field can be formed between two electrodes in the microfluidic channel with an electric double layer, thus driving the controllable electroosmotic flow by biomechanical movements. The performance and operation mechanism of this triboelectric electroosmotic pump (TEOP) is systematically studied and analyzed using a basic free-standing mode TENG. The TEOP produces ≈600 nL min-1 micro-flow with a Joule heat down to 1.76 J cm-3 nL-1 compared with ≈50 nL min-1 and 8.12 J cm-3 nL-1 for an HV-source. The advantages of economy, efficiency, portability, and safety render the TEOP a more conducive option to achieve wider applications in motion-activated micro/nanofluidic transportation and manipulation.
Collapse
Affiliation(s)
- Jianfeng Sun
- Department of Applied Physics, State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, 400044, P. R. China
| | - Lingjun Zhang
- Department of Applied Physics, State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, 400044, P. R. China
| | - Zhongjie Li
- School of Artificial Intelligence, Shanghai University, Shanghai, 200444, P. R. China
| | - Qian Tang
- Department of Applied Physics, State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, 400044, P. R. China
| | - Jie Chen
- College of Physics and Electronic Engineering, Chongqing Normal University, Chongqing, 401331, P. R. China
| | - YingZhou Huang
- Department of Applied Physics, State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, 400044, P. R. China
| | - Chenguo Hu
- Department of Applied Physics, State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, 400044, P. R. China
| | - Hengyu Guo
- Department of Applied Physics, State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, 400044, P. R. China
| | - Yan Peng
- School of Artificial Intelligence, Shanghai University, Shanghai, 200444, P. R. China
| | - Zhong Lin Wang
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 100083, P. R. China
- School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| |
Collapse
|
19
|
Abstract
微型化是现代分析仪器发展的重要趋势。微型化液相色谱仪器在提供与常规尺度液相色谱相同甚至更高分离效率的同时,可以有效减少溶剂和样品的消耗;在液相色谱-质谱联用中,低流速进样可以有效提高质谱离子源的离子化效率,提高质谱检测效率;对于极微量样品的分离,微型化的液相色谱可以有效减少样品稀释;液相色谱的微型化还有利于液相色谱仪器整体的模块化和集成化设计。芯片液相色谱是在微流控芯片上制备色谱柱并集成相应的流体控制系统和检测系统。芯片液相色谱是色谱仪器微型化的一种重要方式,受到学术界和产业界的普遍关注,但是这一方式也充满挑战。液相色谱微流控芯片需要在芯片基底材料、芯片色谱柱的结构设计、微流体控制技术、检测器技术等方面做出创新,使微流控芯片系统适配液相色谱分离技术的需要。目前芯片液相色谱领域面临的主要问题在于芯片基底材料的性质难以满足芯片液相色谱进一步微型化和集成化的需求;因此芯片液相色谱在未来的发展中需要着重关注新型微流控芯片基底材料的开发以及微流控芯片通道结构的统一设计。该文着重介绍了芯片液相色谱技术近年来的研究进展,并简要展示了商品化芯片色谱当前的发展情况。
Collapse
|
20
|
Ji J, Qian S, Liu Z. Electroosmotic Flow of Viscoelastic Fluid through a Constriction Microchannel. MICROMACHINES 2021; 12:mi12040417. [PMID: 33918910 PMCID: PMC8069235 DOI: 10.3390/mi12040417] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 03/22/2021] [Accepted: 04/07/2021] [Indexed: 12/28/2022]
Abstract
Electroosmotic flow (EOF) has been widely used in various biochemical microfluidic applications, many of which use viscoelastic non-Newtonian fluid. This study numerically investigates the EOF of viscoelastic fluid through a 10:1 constriction microfluidic channel connecting two reservoirs on either side. The flow is modelled by the Oldroyd-B (OB) model coupled with the Poisson-Boltzmann model. EOF of polyacrylamide (PAA) solution is studied as a function of the PAA concentration and the applied electric field. In contrast to steady EOF of Newtonian fluid, the EOF of PAA solution becomes unstable when the applied electric field (PAA concentration) exceeds a critical value for a fixed PAA concentration (electric field), and vortices form at the upstream of the constriction. EOF velocity of viscoelastic fluid becomes spatially and temporally dependent, and the velocity at the exit of the constriction microchannel is much higher than that at its entrance, which is in qualitative agreement with experimental observation from the literature. Under the same apparent viscosity, the time-averaged velocity of the viscoelastic fluid is lower than that of the Newtonian fluid.
Collapse
Affiliation(s)
- Jianyu Ji
- Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA;
| | - Shizhi Qian
- Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA;
- Correspondence: ; Tel.: +1-757-683-3304
| | - Zhaohui Liu
- State Key Laboratory of Coal Combustion, School of Energy and Power Engineering, Huazhong University of Science and Technology, Wuhan 430074, China;
| |
Collapse
|
21
|
Perdigones F. Lab-on-PCB and Flow Driving: A Critical Review. MICROMACHINES 2021; 12:175. [PMID: 33578984 PMCID: PMC7916810 DOI: 10.3390/mi12020175] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/30/2021] [Accepted: 02/05/2021] [Indexed: 12/25/2022]
Abstract
Lab-on-PCB devices have been developed for many biomedical and biochemical applications. However, much work has to be done towards commercial applications. Even so, the research on devices of this kind is rapidly increasing. The reason for this lies in the great potential of lab-on-PCB devices to provide marketable devices. This review describes the active flow driving methods for lab-on-PCB devices, while commenting on their main characteristics. Among others, the methods described are the typical external impulsion devices, that is, syringe or peristaltic pumps; pressurized microchambers for precise displacement of liquid samples; electrowetting on dielectrics; and electroosmotic and phase-change-based flow driving, to name a few. In general, there is not a perfect method because all of them have drawbacks. The main problems with regard to marketable devices are the complex fabrication processes, the integration of many materials, the sealing process, and the use of many facilities for the PCB-chips. The larger the numbers of integrated sensors and actuators in the PCB-chip, the more complex the fabrication. In addition, the flow driving-integrated devices increase that difficulty. Moreover, the biological applications are demanding. They require transparency, biocompatibility, and specific ambient conditions. All the problems have to be solved when trying to reach repetitiveness and reliability, for both the fabrication process and the working of the lab-on-PCB, including the flow driving system.
Collapse
Affiliation(s)
- Francisco Perdigones
- Electronic Engineering Department, Higher Technical School of Engineering, University of Seville, 41092 Seville, Spain
| |
Collapse
|
22
|
A Theoretical Investigation on the Heat Transfer Ability of Water-Based Hybrid (Ag–Au) Nanofluids and Ag Nanofluids Flow Driven by Electroosmotic Pumping Through a Microchannel. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2021. [DOI: 10.1007/s13369-020-05265-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
23
|
Ozcelik A, Aslan Z. A practical microfluidic pump enabled by acoustofluidics and 3D printing. MICROFLUIDICS AND NANOFLUIDICS 2021; 25:5. [PMID: 33424526 PMCID: PMC7780904 DOI: 10.1007/s10404-020-02411-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Accepted: 12/04/2020] [Indexed: 05/09/2023]
Abstract
Simple and low-cost solutions are becoming extremely important for the evolving necessities of biomedical applications. Even though, on-chip sample processing and analysis has been rapidly developing for a wide range of screening and diagnostic protocols, efficient and reliable fluid manipulation in microfluidic platforms still require further developments to be considered portable and accessible for low-resource settings. In this work, we present an extremely simple microfluidic pumping device based on three-dimensional (3D) printing and acoustofluidics. The fabrication of the device only requires 3D-printed adaptors, rectangular glass capillaries, epoxy and a piezoelectric transducer. The pumping mechanism relies on the flexibility and complexity of the acoustic streaming patterns generated inside the capillary. Characterization of the device yields controllable and continuous flow rates suitable for on-chip sample processing and analysis. Overall, a maximum flow rate of ~ 12 μL/min and the control of pumping direction by frequency tuning is achieved. With its versatility and simplicity, this microfluidic pumping device offers a promising solution for portable, affordable and reliable fluid manipulation for on-chip applications. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s10404-020-02411-w.
Collapse
Affiliation(s)
- Adem Ozcelik
- Department of Mechanical Engineering, Aydın Adnan Menderes University, Aydın, Turkey
| | - Zeynep Aslan
- Department of Mechanical Engineering, Aydın Adnan Menderes University, Aydın, Turkey
| |
Collapse
|
24
|
A comparison of 2 micron inner diameter open tubular column liquid chromatography with pressure-driven isocratic, slip-flow, and electrochromatographic modes of operation: a theoretical study. J Chromatogr A 2020; 1638:461818. [PMID: 33516049 DOI: 10.1016/j.chroma.2020.461818] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 12/12/2020] [Accepted: 12/13/2020] [Indexed: 11/22/2022]
Abstract
Modifications to the flow profile used in open tube capillary liquid chromatography (OT-CLC) include using slip-flow walls and using electroosmosis as a fluid pump as practiced in electrochromatography. These modifications are implemented experimentally by changing the capillary surface and solvent conditions which results in the change of boundary conditions at the capillary wall. In this paper we employ a theory-based study and compare the zone broadening of simple solutes using parabolic flow from a liquid pump, slip-flow from a highly hydrophobic inner surface with water eluent, and electroosmosis for the conditions of pure water and dilute salt utilizing 2 µm inner diameter OT capillaries. In general, the two types of flow other than parabolic exhibit thin zones in the early part of the chromatogram, consistent with previous studies of slip-flow and electroosmotic flow used in electrochromatography. Electrochromatography is shown to yield higher efficiency and less zone broadening than parabolic and slip-flow conditions used in this study. Nonetheless, it is found that the zone standard deviations are shown to be similar for these flow profiles as is the number of plates for these different flow profiles under the conditions utilized here. It is revealed that these modifications do not warrant the effort to maintain the special solvent conditions when compared to gradient elution OT-CLC, which gives a nearly constant peak width throughout the chromatogram, is easiest to implement, and is the method of choice for complex analysis.
Collapse
|
25
|
Zhang Z, de Graaf J, Faez S. Regulating the aggregation of colloidal particles in an electro-osmotic micropump. SOFT MATTER 2020; 16:10707-10715. [PMID: 33094792 DOI: 10.1039/d0sm01084g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Unrestricted particle transport through microfluidic channels is of paramount importance to a wide range of applications, including lab-on-a-chip devices. In this article, we study via video microscopy the electro-osmotic aggregation of colloidal particles at the opening of a micrometer-sized silica channel in the presence of a salt gradient. Particle aggregation eventually leads to clogging of the channel, which may be undone by a time-adjusted reversal of the applied electric potential. We numerically model our system via the Stokes-Poisson-Nernst-Planck equations in a geometry that approximates the real sample. This allows us to identify the transport processes induced by the electric field and salt gradient and to provide evidence that a balance thereof leads to aggregation. We further demonstrate experimentally that a net flow of colloids through the channel may be achieved by applying a square-waveform electric potential with an appropriately tuned duty cycle. Our results serve to guide the design of microfluidic and nanofluidic pumps that allow for controlled particle transport and provide new insights for anti-fouling in ultra-filtration.
Collapse
Affiliation(s)
- Zhu Zhang
- Nanophotonics, Debye Institute for Nanomaterials Science, Utrecht University, Princetonplein 1, 3584 CC Utrecht, The Netherlands.
| | | | | |
Collapse
|
26
|
Miniaturization of liquid chromatography coupled to mass spectrometry. 3. Achievements on chip-based LC–MS devices. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116003] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
27
|
Cardoso RM, dos Santos RO, Munoz RAA, Garcia CD, Blanes L. A Multi-Pump Magnetohydrodynamics Lab-On-A-Chip Device for Automated Flow Control and Analyte Delivery. SENSORS 2020; 20:s20174909. [PMID: 32877999 PMCID: PMC7506898 DOI: 10.3390/s20174909] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/15/2020] [Accepted: 08/24/2020] [Indexed: 11/16/2022]
Abstract
This article shows the development of a computer-controlled lab-on-a-chip device with three magnetohydrodynamic (MHD) pumps and a pneumatic valve. The chip was made of a stack of layers of polymethylmethacrylate (PMMA), cut using a laser engraver and thermally bonded. The MHD pumps were built using permanent magnets (neodymium) and platinum electrodes, all of them controlled by an Arduino board and a set of relays. The implemented pumps were able to drive solutions in the open channels with a flow rate that increased proportionally with the channel width and applied voltage. To address the characteristic low pressures generated by this kind of pump, all channels were interconnected. Because the electrodes were immersed in the electrolyte, causing electrolysis and pH variations, the composition and ionic strength of the electrolyte solution were controlled. Additionally, side structures for releasing bubbles were integrated. With this multi-pump and valve solution, the device was used to demonstrate the possibility of performing an injection sequence in a system that resembles a traditional flow injection analysis system. Ultimately, the results demonstrate the possibility of performing injection sequences using an array of MHD pumps that can perform fluid handling in the 0-5 µL s-1 range.
Collapse
Affiliation(s)
- Rafael M. Cardoso
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia 38400-000, Brazil; (R.M.C.); (R.A.A.M.)
| | - Robson O. dos Santos
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Curitiba 81350-010, Brazil;
| | - Rodrigo A. A. Munoz
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia 38400-000, Brazil; (R.M.C.); (R.A.A.M.)
| | - Carlos D. Garcia
- Department of Chemistry, Clemson University, Clemson, SC 29634, USA
- Correspondence: (C.D.G); (L.B.)
| | - Lucas Blanes
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Curitiba 81350-010, Brazil;
- Correspondence: (C.D.G); (L.B.)
| |
Collapse
|
28
|
Barragán VM, Villaluenga JPG, Morales-Villarejo V, Izquierdo-Gil MA. Electro-Osmotic Behavior of Polymeric Cation-Exchange Membranes in Ethanol-Water Solutions. ENTROPY (BASEL, SWITZERLAND) 2020; 22:e22060692. [PMID: 33286464 PMCID: PMC7517228 DOI: 10.3390/e22060692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 06/17/2020] [Accepted: 06/19/2020] [Indexed: 06/12/2023]
Abstract
The aim of this work is to apply linear non-equilibrium thermodynamics to study the electrokinetic properties of three cation-exchange membranes of different structures in ethanol-water electrolyte solutions. To this end, liquid uptake and electro-osmotic permeability were estimated with potassium chloride ethanol-water solutions with different ethanol proportions as solvent. Current-voltage curves were also measured for each membrane system to estimate the energy dissipation due to the Joule effect. Considering the Onsager reciprocity relations, the streaming potential coefficient was discussed in terms of ethanol content of the solutions and the membrane structure. The results showed that more porous heterogeneous membrane presented lower values of liquid uptake and streaming potential coefficient with increasing ethanol content. Denser homogeneous membrane showed higher values for both, solvent uptake and streaming coefficient for intermediate content of ethanol.
Collapse
|
29
|
Sun Y, Lin S, Zhang F, Yang B. Electrodialysis Pump Based on Enhanced Water Dissociation of Bipolar Membrane. Anal Chem 2020; 92:6263-6268. [PMID: 32295341 DOI: 10.1021/acs.analchem.0c01077] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We describe a novel micropump mode-electrodialysis pump (EDP), which is based on the recombination of hydrogen and hydroxyl ions generated by enhanced water dissociation of bipolar membrane (BPM). The pump is in a sandwich-like configuration in which the central production channel is spatially isolated from two outer regenerant chambers by a BPM, respectively. Both BPMs are put at the same direction, in which the anion exchange membrane (AEM) side is facing the anode with respect to the cation exchange membrane (CEM) side facing the cathode. Pure water as the feed solution flows through the regenerant chambers at a conventional flow rate (e.g., 0.2 mL/min). Under the electric field, enhanced water dissociation at the junction layer of BPM will occur, generating hydroxyl and hydrogen ions. Their electrodialytic migration into the central channel will recombine water and its flow rate is correlated with the applied current. The pump shows near-ideal Faradaic efficiency and at least 0.8 μL/min can be achieved by controlling the current. The produced water is near neutral and obvious enrichment of trace impurity anions is observed in the production channel.
Collapse
Affiliation(s)
- Yue Sun
- Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, China
| | - Shiyuan Lin
- Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, China
| | - Feifang Zhang
- Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, China
| | - Bingcheng Yang
- Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, China
| |
Collapse
|
30
|
Zhao Y, Zhang P, Wang J, Zhou L, Yang R. A novel electro-driven immunochromatography assay based on upconversion nanoparticles for rapid pathogen detection. Biosens Bioelectron 2020; 152:112037. [DOI: 10.1016/j.bios.2020.112037] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 01/14/2020] [Accepted: 01/17/2020] [Indexed: 02/08/2023]
|
31
|
Miniaturized liquid chromatography focusing on analytical columns and mass spectrometry: A review. Anal Chim Acta 2020; 1103:11-31. [DOI: 10.1016/j.aca.2019.12.064] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 12/19/2019] [Accepted: 12/20/2019] [Indexed: 12/17/2022]
|
32
|
Ostromohov N, Rofman B, Bercovici M, Kaigala G. Electrokinetic Scanning Probe. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1904268. [PMID: 31885215 DOI: 10.1002/smll.201904268] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 11/25/2019] [Indexed: 06/10/2023]
Abstract
The theoretical analysis and experimental demonstration of a new concept are presented for a non-contact scanning probe, in which transport of fluid and molecules is controlled by electric fields. The electrokinetic scanning probe (ESP) enables local chemical and biochemical interactions with surfaces in liquid environments. The physical mechanism and design criteria for such a probe are presented, and its compatibility with a wide range of processing solutions and pH values are demonstrated. The applicability of the probe is shown for surface patterning in conjunction with localized heating and 250-fold analyte stacking.
Collapse
Affiliation(s)
- Nadya Ostromohov
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
- IBM Research-Zurich, Saeumerstrasse 4, CH-8803, Rueschlikon, Switzerland
| | - Baruch Rofman
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Moran Bercovici
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Govind Kaigala
- IBM Research-Zurich, Saeumerstrasse 4, CH-8803, Rueschlikon, Switzerland
| |
Collapse
|
33
|
Electroosmotic Flow of Viscoelastic Fluid in a Nanochannel Connecting Two Reservoirs. MICROMACHINES 2019; 10:mi10110747. [PMID: 31683717 PMCID: PMC6915621 DOI: 10.3390/mi10110747] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 10/29/2019] [Accepted: 10/30/2019] [Indexed: 02/04/2023]
Abstract
: Electroosmotic flow (EOF) of viscoelastic fluid with Linear Phan-Thien-Tanner (LPTT) constitutive model in a nanochannel connecting two reservoirs is numerically studied. For the first time, the influence of viscoelasticity on the EOF and the ionic conductance in the micro-nanofluidic interconnect system, with consideration of the electrical double layers (EDLs), is investigated. Regardless of the bulk salt concentration, significant enhancement of the flow rate is observed for viscoelastic fluid compared to the Newtonian fluid, due to the shear thinning effect. An increase in the ionic conductance of the nanochannel occurs for the viscoelastic fluid. The enhancement of the ionic conductance is significant under the overlapping EDLs condition.
Collapse
|
34
|
Filippov AN, Shkirskaya SA. Approbation of the Cell Model of a Cation-Exchange Membrane on 1 : 1 Electrolytes. MEMBRANES AND MEMBRANE TECHNOLOGIES 2019. [DOI: 10.1134/s2517751619050020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
35
|
Filippov AN, Shkirskaya SA. Verification of the Cell (Heterogeneous) Model of an Ion-Exchange Membrane and Its Comparison with the Homogeneous Model. COLLOID JOURNAL 2019. [DOI: 10.1134/s1061933x19050041] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|