1
|
Sevgen S, Kara G, Kir AS, Şahin A, Boyaci E. A critical review of bioanalytical and clinical applications of solid phase microextraction. J Pharm Biomed Anal 2025; 252:116487. [PMID: 39378761 DOI: 10.1016/j.jpba.2024.116487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 09/07/2024] [Accepted: 09/26/2024] [Indexed: 10/10/2024]
Abstract
Studying the functions, mechanisms, and effects of drugs and other exogenous compounds on biological systems, together with investigations performed to understand biosystems better, comprises one of the most fascinating areas of research. Although classical sample preparation techniques are dominantly used to infer the relevant information from the investigated system, they fail to meet various imperative requirements, such as being environmentally friendly, applicable in-vivo, and compatible with online analysis. As a chameleon in the analytical toolbox, solid phase microextraction (SPME) is one of the best tools available for studying biological systems in unconventional ways. In this review, SPME is spotlighted, and its capability for bioanalytical applications, including drug analysis, untargeted and targeted metabolomics, in-vivo and clinical studies, is scrutinized based on studies reported in the past five years. In addition, novel extractive phases and instrumental coupling strategies developed to serve bioanalytical research are discussed to give the perspective for state-of-the-art and future developments. The literature assessment showed that SPME could act as a critical tool to investigate in-vivo biological systems and provide information about the elusive portion of the metabolome. Moreover, recently introduced miniaturized SPME probes further improved the low-invasive nature of the sampling and enabled sampling even from a single cell. The coupling of SPME directly to mass spectrometry significantly reduced the total analytical workflow and became one of the promising tools suitable for fast diagnostic purposes and drug analysis. The numerous applications and advancements reported in bioanalysis using SPME show that it will continue to be an indispensable technique in the future.
Collapse
Affiliation(s)
- Sılanur Sevgen
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Gökşin Kara
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Aysegul Seyma Kir
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Alper Şahin
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Ezel Boyaci
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye.
| |
Collapse
|
2
|
Kataoka H, Ishizaki A, Saito K, Ehara K. Developments and Applications of Molecularly Imprinted Polymer-Based In-Tube Solid Phase Microextraction Technique for Efficient Sample Preparation. Molecules 2024; 29:4472. [PMID: 39339467 PMCID: PMC11433927 DOI: 10.3390/molecules29184472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2024] [Revised: 09/15/2024] [Accepted: 09/18/2024] [Indexed: 09/30/2024] Open
Abstract
Despite advancements in the sensitivity and performance of analytical instruments, sample preparation remains a bottleneck in the analytical process. Currently, solid-phase extraction is more widely used than traditional organic solvent extraction due to its ease of use and lower solvent requirements. Moreover, various microextraction techniques such as micro solid-phase extraction, dispersive micro solid-phase extraction, solid-phase microextraction, stir bar sorptive extraction, liquid-phase microextraction, and magnetic bead extraction have been developed to minimize sample size, reduce solvent usage, and enable automation. Among these, in-tube solid-phase microextraction (IT-SPME) using capillaries as extraction devices has gained attention as an advanced "green extraction technique" that combines miniaturization, on-line automation, and reduced solvent consumption. Capillary tubes in IT-SPME are categorized into configurations: inner-wall-coated, particle-packed, fiber-packed, and rod monolith, operating either in a draw/eject system or a flow-through system. Additionally, the developments of novel adsorbents such as monoliths, ionic liquids, restricted-access materials, molecularly imprinted polymers (MIPs), graphene, carbon nanotubes, inorganic nanoparticles, and organometallic frameworks have improved extraction efficiency and selectivity. MIPs, in particular, are stable, custom-made polymers with molecular recognition capabilities formed during synthesis, making them exceptional "smart adsorbents" for selective sample preparation. The MIP fabrication process involves three main stages: pre-arrangement for recognition capability, polymerization, and template removal. After forming the template-monomer complex, polymerization creates a polymer network where the template molecules are anchored, and the final step involves removing the template to produce an MIP with cavities complementary to the template molecules. This review is the first paper to focus on advanced MIP-based IT-SPME, which integrates the selectivity of MIPs into efficient IT-SPME, and summarizes its recent developments and applications.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan
| | - Atsushi Ishizaki
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan
| | - Keita Saito
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan
| | - Kentaro Ehara
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan
| |
Collapse
|
3
|
Inamassu CH, Raspini E Silva L, Marchioni C. Recent advances in the chromatographic analysis of endocannabinoids and phytocannabinoids in biological samples. J Chromatogr A 2024; 1732:465225. [PMID: 39128236 DOI: 10.1016/j.chroma.2024.465225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 07/30/2024] [Accepted: 07/31/2024] [Indexed: 08/13/2024]
Abstract
Endocannabinoid system, including endocannabinoid neurotransmitters (eCBs), has gained much attention over the last years due to its involvement with the pathophysiology of diseases and the potential use of Cannabis sativa (marijuana). The identification of eCBs and phytocannabinoids in biological samples for forensic, clinical, or therapeutic drug monitoring purposes constitutes a still significant challenge. In this scoping review, the recent advantages, and limitations of the eCBs and phytocannabinoids quantification in biological samples are described. Published studies from 2018-2023 were searched in 8 databases, and after screening and exclusions, the selected 38 articles had their data tabulated, summarized, and analyzed. The main characteristics of the eCBs and phytocannabinoids analyzed and the potential use of each biological sample were described, indicating gaps in the literature that still need to be explored. Well-established and innovative sample preparation protocols, and chromatographic separations, such as GC, HPLC, and UHPLC, are reviewed highlighting their respective advantages, drawbacks, and challenges. Lastly, future approaches, challenges, and tendencies in the quantification analysis of cannabinoids are discussed.
Collapse
Affiliation(s)
- Carolina Henkes Inamassu
- Program on Pharmacology, Federal University of Santa Catarina, Campus Universitário, s/n, Sala 208, Bloco E, Prédio Administrativo - Córrego Grande, Florianópolis, SC 88040-900, Brazil
| | - Luisa Raspini E Silva
- Program on Pharmacology, Federal University of Santa Catarina, Campus Universitário, s/n, Sala 208, Bloco E, Prédio Administrativo - Córrego Grande, Florianópolis, SC 88040-900, Brazil
| | - Camila Marchioni
- Department of Pathology, Federal University of Santa Catarina, Rua Engenheiro Agronômico Andrei Cristian Ferreira, s/n - Trindade, Florianópolis, SC 88040-900, Brazil.
| |
Collapse
|
4
|
Nahar L, Chaiwut P, Sangthong S, Theansungnoen T, Sarker SD. Progress in the analysis of phytocannabinoids by HPLC and UPLC (or UHPLC) during 2020-2023. PHYTOCHEMICAL ANALYSIS : PCA 2024; 35:927-989. [PMID: 38837522 DOI: 10.1002/pca.3374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 04/22/2024] [Accepted: 04/22/2024] [Indexed: 06/07/2024]
Abstract
INTRODUCTION Organic molecules that bind to cannabinoid receptors are known as cannabinoids. These molecules possess pharmacological properties similar to those produced by Cannabis sativa L. High-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC, also known as ultra-high-performance liquid chromatography, UHPLC) have become the most widely used analytical tools for detection and quantification of phytocannabinoids in various matrices. HPLC and UPLC (or UHPLC) are usually coupled to an ultraviolet (UV), photodiode array (PDA), or mass spectrometric (MS) detector. OBJECTIVE To critically appraise the literature on the application of HPLC and UPLC (or UHPLC) methods for the analysis of phytocannabinoids published from January 2020 to December 2023. METHODOLOGY An extensive literature search was conducted using Web of Science, PubMed, and Google Scholar and published materials including relevant books. In various combinations, using cannabinoid in all combinations, cannabis, hemp, hashish, C. sativa, marijuana, analysis, HPLC, UHPLC, UPLC, and quantitative, qualitative, and quality control were used as the keywords for the literature search. RESULTS Several HPLC- and UPLC (or UHPLC)-based methods for the analysis of phytocannabinoids were reported. While simple HPLC-UV or HPLC-PDA-based methods were common, the use of HPLC-MS, HPLC-MS/MS, UPLC (or UHPLC)-PDA, UPLC (or UHPLC)-MS, and UPLC (or UHPLC)-MS/MS was also reported. Applications of mathematical and computational models for optimization of protocols were noted. Pre-analyses included various environmentally friendly extraction protocols. CONCLUSION During the last 4 years, HPLC and UPLC (or UHPLC) remained the main analytical tools for phytocannabinoid analysis in different matrices.
Collapse
Affiliation(s)
- Lutfun Nahar
- Laboratory of Growth Regulators, Palacký University and Institute of Experimental Botany, The Czech Academy of Sciences, Olomouc, Czech Republic
| | - Phanuphong Chaiwut
- Green Cosmetic Technology Research Group, School of Cosmetic Science, Mae Fah Luang University, Chiang Rai, Thailand
| | - Sarita Sangthong
- Green Cosmetic Technology Research Group, School of Cosmetic Science, Mae Fah Luang University, Chiang Rai, Thailand
| | - Tinnakorn Theansungnoen
- Green Cosmetic Technology Research Group, School of Cosmetic Science, Mae Fah Luang University, Chiang Rai, Thailand
| | - Satyajit D Sarker
- Centre for Natural Products Discovery, School of Pharmacy and Biomolecular Sciences, Liverpool John Moores University, Liverpool, UK
| |
Collapse
|
5
|
Li N, Zhang Z, Li G. Recent advance on microextraction sampling technologies for bioanalysis. J Chromatogr A 2024; 1720:464775. [PMID: 38452559 DOI: 10.1016/j.chroma.2024.464775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 01/14/2024] [Accepted: 02/26/2024] [Indexed: 03/09/2024]
Abstract
The contents of target substances in biological samples are usually at low concentration levels, and the matrix of biological samples is usually complex. Sample preparation is considered a very critical step in bioanalysis. At present, the utilization of microextraction sampling technology has gained considerable prevalence in the realm of biological analysis. The key developments in this field focus on the efficient microextraction media and the miniaturization and automation of adaptable sample preparation methods currently. In this review, the recent progress on the microextraction sampling technologies for bioanalysis has been introduced from point of view of the preparation of microextraction media and the microextraction sampling strategies. The advance on the microextraction media was reviewed in detail, mainly including the aptamer-functionalized materials, molecularly imprinted polymers, carbon-based materials, metal-organic frameworks, covalent organic frameworks, etc. The advance on the microextraction sampling technologies was summarized mainly based on in-vivo sampling, in-vitro sampling and microdialysis technologies. Moreover, the current challenges and perspective on the future trends of microextraction sampling technologies for bioanalysis were briefly discussed.
Collapse
Affiliation(s)
- Na Li
- School of Chemistry, Sun Yat-sen University, Guangzhou 510006, China
| | - Zhuomin Zhang
- School of Chemistry, Sun Yat-sen University, Guangzhou 510006, China.
| | - Gongke Li
- School of Chemistry, Sun Yat-sen University, Guangzhou 510006, China.
| |
Collapse
|
6
|
Leszczyńska D, Hallmann A, Treder N, Bączek T, Roszkowska A. Recent advances in the use of SPME for drug analysis in clinical, toxicological, and forensic medicine studies. Talanta 2024; 270:125613. [PMID: 38159351 DOI: 10.1016/j.talanta.2023.125613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/21/2023] [Accepted: 12/27/2023] [Indexed: 01/03/2024]
Abstract
Solid-phase microextraction (SPME) has gained attention as a simple, fast, and non-exhaustive extraction technique, as its unique features enable its use for the extraction of many classes of drugs from biological matrices. This sample-preparation approach consolidates sampling and sample preparation into a single step, in addition to providing analyte preconcentration and sample clean-up. These features have helped SPME become an integral part of several analytical protocols for monitoring drug concentrations in human matrices in clinical, toxicological, and forensic medicine studies. Over the years, researchers have continued to develop the SPME technique, resulting in the introduction of novel sorbents and geometries, which have resulted in improved extraction efficiencies. This review summarizes developments and applications of SPME published between 2016 and 2022, specifically in relation to the analysis of central nervous system drugs, drugs used to treat cardiovascular disorders and bacterial infections, and drugs used in immunosuppressive and anticancer therapies.
Collapse
Affiliation(s)
- Dagmara Leszczyńska
- Department of Pharmaceutical Biochemistry, Medical University of Gdańsk, Gdańsk, 80-211, Poland
| | - Anna Hallmann
- Department of Pharmaceutical Biochemistry, Medical University of Gdańsk, Gdańsk, 80-211, Poland
| | - Natalia Treder
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, 80-416, Poland
| | - Tomasz Bączek
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, 80-416, Poland
| | - Anna Roszkowska
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, 80-416, Poland.
| |
Collapse
|
7
|
Cardoso AT, Martins RO, Lanças FM, Chaves AR. Molecularly imprinted polymers in online extraction liquid chromatography methods: Current advances and recent applications. Anal Chim Acta 2023; 1284:341952. [PMID: 37996153 DOI: 10.1016/j.aca.2023.341952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 10/20/2023] [Accepted: 10/21/2023] [Indexed: 11/25/2023]
Abstract
BACKGROUND One of the primary objectives in green analytical practices is the seamless integration of extraction and separation steps, resulting in the augmentation of both analytical throughput and method performance. Consequently, the exploration of prospective sorbent materials has drawn significant attention in the scientific community, particularly concerning the potential for online procedures. Employing the optimal sorbent material within an automated analytical approach holds the promise of elevating the precision of the analytical evaluation. Molecularly imprinted polymers (MIPs) excel in specific analyte interaction within complex matrices. However, MIPs' full potential was not widely exploring especially for online analytical methodologies. RESULTS Here is presented a comprehensive overview of the current applications of MIPs as sorbent materials within integrated and automated separation methodologies applied to diverse matrices including biological, food, and environmental samples. Notably, their primary advantage, as evidenced in the literature, lies in their exceptional selectivity for the target analyte discussed according to the adopted synthesis protocol. Furthermore, the literature discussed here illustrates the versatility of MIPs in terms of modification with one or more phases which are so-called hybrid materials, such as molecularly imprinted monoliths (MIM), the molecularly imprinted ionic liquid polymer (IL-MIP), and restricted access to molecularly imprinted polymer (RAMIP). The reported advantages enhance their applicability in integrated and automated separation procedures, especially to the column switching methods, across a broader spectrum of applications. SIGNIFICANCE This revision aims to demonstrate the MIP's potential as a sorbent phase in integrated and automated methods, this comprehensive overview of MIP polymers in integrated and automated separation methodologies can be used as a valuable guide, inspiring new research on developing novel horizons for MIP applications to have their potential emphasized in analytical science and enhanced to the great analytical methods achievement.
Collapse
Affiliation(s)
- Alessandra Timóteo Cardoso
- Universidade Federal de Goiás, Instituto de Química, 74690-900, Goiânia, GO, Brazil; Universidade de São Paulo, Instituto de Química de São Carlos, São Carlos, SP, Brazil
| | | | - Fernando Mauro Lanças
- Universidade de São Paulo, Instituto de Química de São Carlos, São Carlos, SP, Brazil
| | | |
Collapse
|
8
|
Woźniczka K, Konieczyński P, Plenis A, Bączek T, Roszkowska A. SPME as a green sample-preparation technique for the monitoring of phytocannabinoids and endocannabinoids in complex matrices. J Pharm Anal 2023; 13:1117-1134. [PMID: 38024858 PMCID: PMC10657972 DOI: 10.1016/j.jpha.2023.06.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 06/10/2023] [Accepted: 06/27/2023] [Indexed: 12/01/2023] Open
Abstract
The endocannabinoid system (ECS), particularly its signaling pathways and ligands, has garnered considerable interest in recent years. Along with clinical work investigating the ECS' functions, including its role in the development of neurological and inflammatory conditions, much research has focused on developing analytical protocols enabling the precise monitoring of the levels and metabolism of the most potent ECS ligands: exogenous phytocannabinoids (PCs) and endogenous cannabinoids (endocannabinoids, ECs). Solid-phase microextraction (SPME) is an advanced, non-exhaustive sample-preparation technique that facilitates the precise and efficient isolation of trace amounts of analytes, thus making it appealing for the analysis of PCs and ECs in complex matrices of plant and animal/human origin. In this paper, we review recent forensic medicine and toxicological studies wherein SPME has been applied to monitor levels of PCs and ECs in complex matrices, determine their effects on organism physiology, and assess their role in the development of several diseases.
Collapse
Affiliation(s)
- Katarzyna Woźniczka
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Paweł Konieczyński
- Department of Analytical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Alina Plenis
- Department of Analytical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Tomasz Bączek
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Anna Roszkowska
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| |
Collapse
|
9
|
Sartore DM, Vargas Medina DA, Bocelli MD, Jordan-Sinisterra M, Santos-Neto ÁJ, Lanças FM. Modern automated microextraction procedures for bioanalytical, environmental, and food analyses. J Sep Sci 2023; 46:e2300215. [PMID: 37232209 DOI: 10.1002/jssc.202300215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/02/2023] [Accepted: 05/04/2023] [Indexed: 05/27/2023]
Abstract
Sample preparation frequently is considered the most critical stage of the analytical workflow. It affects the analytical throughput and costs; moreover, it is the primary source of error and possible sample contamination. To increase efficiency, productivity, and reliability, while minimizing costs and environmental impacts, miniaturization and automation of sample preparation are necessary. Nowadays, several types of liquid-phase and solid-phase microextractions are available, as well as different automatization strategies. Thus, this review summarizes recent developments in automated microextractions coupled with liquid chromatography, from 2016 to 2022. Therefore, outstanding technologies and their main outcomes, as well as miniaturization and automation of sample preparation, are critically analyzed. Focus is given to main microextraction automation strategies, such as flow techniques, robotic systems, and column-switching approaches, reviewing their applications to the determination of small organic molecules in biological, environmental, and food/beverage samples.
Collapse
Affiliation(s)
- Douglas M Sartore
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Deyber A Vargas Medina
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Marcio D Bocelli
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Marcela Jordan-Sinisterra
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Álvaro J Santos-Neto
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Fernando M Lanças
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| |
Collapse
|
10
|
Roszkowska A, Klejbor I, Bogusiewicz J, Plenis A, Bojko B, Kowalik K, Moryś J, Bączek T. Monitoring of age- and gender-related alterations of endocannabinoid levels in selected brain regions with the use of SPME probes. Metabolomics 2023; 19:40. [PMID: 37043024 PMCID: PMC10097736 DOI: 10.1007/s11306-023-02007-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 04/05/2023] [Indexed: 04/13/2023]
Abstract
INTRODUCTION The endocannabinoid system consists of different types of receptors, enzymes and endocannabinoids (ECs), which are involved in several physiological processes, but also play important role in the development and progression of central nervous system disorders. OBJECTIVES The purpose of this study was to apply precise and sensitive methodology for monitoring of four ECs, namely anandamide (AEA), 2-arachidonoyl glycerol (2-AG), N-arachidonoyl dopamine (NADA), 2-arachidonyl glyceryl ether (2-AGe) in selected brain regions of female and male rats at different stages of development (young, adult and old). METHODS Biocompatible solid-phase microextraction (SPME) probes were introduced into the intact (non-homogenized) brain structures for isolation of four ECs, and the extracts were subjected to LC-MS/MS analysis. Two chemometric approaches, namely hierarchical cluster analysis (HCA) and Principal Component Analysis (PCA) were applied to provide more information about the levels of 2-AG and AEA in different brain structures. RESULTS 2-AG and AEA were extracted and could be quantified in each brain region; the level of 2-AG was significantly higher in comparison to the level of AEA. Two highly unstable ECs, NADA and 2-AGe, were captured by SPME probes from intact brain samples for the first time. CONCLUSION SPME probes were able to isolate highly unstable endogenous compounds from intact tissue, and provided new tools for precise analysis of the level and distribution of ECs in different brain regions. Monitoring of ECs in brain samples is important not only in physiological conditions, but also may contribute to better understanding of the functioning of the endocannabinoid system in various disorders.
Collapse
Affiliation(s)
- Anna Roszkowska
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland.
| | - Ilona Klejbor
- Department of Anatomy, Institute of Medical Sciences, Jan Kochanowski University, Kielce, Poland
| | - Joanna Bogusiewicz
- Department of Pharmacodynamics and Molecular Pharmacology, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, Bydgoszcz, Poland
| | - Alina Plenis
- Department of Analytical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Barbara Bojko
- Department of Pharmacodynamics and Molecular Pharmacology, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, Bydgoszcz, Poland
| | - Katarzyna Kowalik
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Janusz Moryś
- Department of Normal Anatomy, Pomeranian Medical University, Szczecin, Poland
| | - Tomasz Bączek
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| |
Collapse
|
11
|
Dawidowicz AL, Dybowski MP, Typek R, Rombel M, Holowinski P. Unexpected formation of dichloroacetic and trichloroacetic artefacts in gas chromatograph injector during Cannabidiol analysis. J Pharm Biomed Anal 2023; 230:115388. [PMID: 37086553 DOI: 10.1016/j.jpba.2023.115388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 04/04/2023] [Accepted: 04/07/2023] [Indexed: 04/24/2023]
Abstract
The knowledge about the stability of compounds and possible ways of their transformation in the process of sample preparation for analysis and during analysis itself is very helpful in the assessment of possible errors which can appear when an accurate and precise estimation of compound concentration in tested samples is attempted. The present paper shows that a significant amount of CBD present in the blood/plasma sample analyzed by means of GC transforms in the hot GC injector not only to 9α-hydroxyhexahydrocannabinol, 8-hydroxy-iso-hexahydrocannabinol, Δ9-tetrahydrocannabinol, Δ8-tetrahydrocannabinol, and cannabinol but also to the trichloroacetic esters of Δ9-THC and Δ8-THC and, unexpectedly, to their dichloroacetic esters when trichloroacetic acid is used as protein precipitation agent. The increase of GC injector temperature favors the formation of dichloroacetic esters of Δ9-THC and Δ8-THC in relation to their trichloroacetic ones. The appearance of dichloroacetic esters of Δ9-THC and Δ8-THC among CBD transformation products is probably the result of the thermal decomposition of their trichloroacetic esters. The transformation of trichloroacetic derivatives of organic compounds into their dichloroacetic derivatives in GC injector has not been reported yet. The instability of trichloroacetic derivatives of Δ8-/Δ9-THC during their GC analysis is probably accounts for the lack of their GC-MS spectra in the databases. NMR, GC-MS and LC-MS spectra of the newly discovered derivatives constitute an important element of the work. The obtained results demonstrate why the use of trichloroacetic acid for plasma samples deproteinization should be avoided when CBD and/or THC are determined by GC.
Collapse
Affiliation(s)
- Andrzej L Dawidowicz
- Department of Chromatography, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie Sklodowska University in Lublin, Lublin 20-031, Poland.
| | - Michal P Dybowski
- Department of Chromatography, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie Sklodowska University in Lublin, Lublin 20-031, Poland.
| | - Rafal Typek
- Department of Chromatography, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie Sklodowska University in Lublin, Lublin 20-031, Poland
| | - Michal Rombel
- Department of Chromatography, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie Sklodowska University in Lublin, Lublin 20-031, Poland
| | - Piotr Holowinski
- Department of Chromatography, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie Sklodowska University in Lublin, Lublin 20-031, Poland
| |
Collapse
|
12
|
Krishnamurthy S, Kadu RD. A comprehensive review on detection of cannabinoids using hyphenated techniques. CHEMICAL PAPERS 2023. [DOI: 10.1007/s11696-023-02732-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/05/2023]
|
13
|
Mandal S, Poi R, Hazra DK, Ansary I, Bhattacharyya S, Karmakar R. Review of extraction and detection techniques for the analysis of pesticide residues in fruits to evaluate food safety and make legislative decisions: Challenges and anticipations. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1215:123587. [PMID: 36628882 DOI: 10.1016/j.jchromb.2022.123587] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 12/13/2022] [Accepted: 12/24/2022] [Indexed: 12/28/2022]
Abstract
Fruits are vital parts of the human diet because they include necessary nutrients that the body needs. Pesticide use has increased dramatically in recent years to combat fruit pests across the world. Pesticide usage during production, on the other hand, frequently results in undesirable residues in fruits after harvest. Consumers are concerned about pesticide residues since most of the fruits are directly consumed and even recommended for the patients as dietary supplements. As a result of this worry, pesticide residues in fruits are being randomly monitored to re-assess the food safety situation and make informed legislative decisions. To assess the degree of pesticide residues in fruits, a simple and quick analytical procedure is usually required. As a result, pesticide residue detection (using various analytical techniques: GC, LC and Biosensors) becomes critical, and regulatory directives are formed to regulate their amounts via the Maximum Residue Limit (MRL). Over the previous two decades, a variety of extraction techniques and analytical methodologies for xenobiotic's efficient extraction, identification, confirmation and quantification have been developed, ranging from traditional to advanced. The goal of this review is to give readers an overview of the evolution of numerous extraction and detection methods for pesticide residue analysis in fruits. The objective is to assist analysts in better understanding how the ever-changing regulatory landscape might drive the need for new analytical methodologies to be developed in order to comply with current standards and safeguard consumers.
Collapse
Affiliation(s)
- Swagata Mandal
- All India Network Project on Pesticide Residues, Directorate of Research, Bidhan Chandra Krishi Viswavidyalaya, Kalyani, Nadia, West Bengal, India; Department of Chemistry, Burdwan University, Burdwan, West Bengal 713104, India
| | - Rajlakshmi Poi
- All India Network Project on Pesticide Residues, Directorate of Research, Bidhan Chandra Krishi Viswavidyalaya, Kalyani, Nadia, West Bengal, India
| | - Dipak Kumar Hazra
- All India Network Project on Pesticide Residues, Directorate of Research, Bidhan Chandra Krishi Viswavidyalaya, Kalyani, Nadia, West Bengal, India
| | - Inul Ansary
- Department of Chemistry, Burdwan University, Burdwan, West Bengal 713104, India
| | - Sudip Bhattacharyya
- All India Network Project on Pesticide Residues, Directorate of Research, Bidhan Chandra Krishi Viswavidyalaya, Kalyani, Nadia, West Bengal, India
| | - Rajib Karmakar
- All India Network Project on Pesticide Residues, Directorate of Research, Bidhan Chandra Krishi Viswavidyalaya, Kalyani, Nadia, West Bengal, India.
| |
Collapse
|
14
|
Suzaei FM, Daryanavard SM, Abdel-Rehim A, Bassyouni F, Abdel-Rehim M. Recent molecularly imprinted polymers applications in bioanalysis. CHEMICAL PAPERS 2023; 77:619-655. [PMID: 36213319 PMCID: PMC9524737 DOI: 10.1007/s11696-022-02488-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Accepted: 09/10/2022] [Indexed: 11/18/2022]
Abstract
Molecular imprinted polymers (MIPs) as extraordinary compounds with unique features have presented a wide range of applications and benefits to researchers. In particular when used as a sorbent in sample preparation methods for the analysis of biological samples and complex matrices. Its application in the extraction of medicinal species has attracted much attention and a growing interest. This review focus on articles and research that deals with the application of MIPs in the analysis of components such as biomarkers, drugs, hormones, blockers and inhibitors, especially in biological matrices. The studies based on MIP applications in bioanalysis and the deployment of MIPs in high-throughput settings and optimization of extraction methods are presented. A review of more than 200 articles and research works clearly shows that the superiority of MIP techniques lies in high accuracy, reproducibility, sensitivity, speed and cost effectiveness which make them suitable for clinical usage. Furthermore, this review present MIP-based extraction techniques and MIP-biosensors which are categorized on their classes based on common properties of target components. Extraction methods, studied sample matrices, target analytes, analytical techniques and their results for each study are described. Investigations indicate satisfactory results using MIP-based bioanalysis. According to the increasing number of studies on method development over the last decade, the use of MIPs in bioanalysis is growing and will further expand the scope of MIP applications for less studied samples and analytes.
Collapse
Affiliation(s)
- Foad Mashayekhi Suzaei
- Toxicology Laboratories, Monitoring the Human Hygiene Condition & Standard of Qeshm (MHCS Company), Qeshm Island, Iran
| | - Seyed Mosayeb Daryanavard
- grid.444744.30000 0004 0382 4371Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- grid.5335.00000000121885934Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Fatma Bassyouni
- grid.419725.c0000 0001 2151 8157Chemistry of Natural and Microbial Products Department, Pharmaceutical industry Research Division, National Research Centre, Cairo, 12622 Egypt
| | - Mohamed Abdel-Rehim
- grid.5037.10000000121581746Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden and Med. Solutions, Stockholm, Sweden
| |
Collapse
|
15
|
P03-09 Development of a new microextraction technique for the analysis of synthetic cannabinoids in plasma based on the principles of Green Analytical Toxicology. Toxicol Lett 2022. [DOI: 10.1016/j.toxlet.2022.07.271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
16
|
Morisue Sartore D, Costa JL, Lanças FM, Santos-Neto ÁJ. Packed in-tube SPME-LC-MS/MS for fast and straightforward analysis of cannabinoids and metabolites in human urine. Electrophoresis 2022; 43:1555-1566. [PMID: 35430741 DOI: 10.1002/elps.202100389] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 03/12/2022] [Accepted: 04/07/2022] [Indexed: 11/10/2022]
Abstract
Cannabinoids are pharmacologically active compounds present in cannabis plants, which have become important research topics in the modern toxicological and medical research fields. Not only is cannabis the most used drug globally, but also cannabinoids have a growing use to treat a series of diseases. Therefore, new, fast, and efficient analytical methods for analyzing these substances in different matrices are demanded. This study developed a new packed-in-tube solid-phase microextraction (IT-SPME) method coupled to liquid chromatography with tandem mass spectrometry (LC-MS/MS), for the automated microextraction of seven cannabinoids from human urine. Packed IT-SPME microcolumns were prepared in (508 µm i.d. × 50 mm) stainless-steel hardware; each one required only 12 mg of sorbent phase. Different sorbents were evaluated; fractional factorial design 24-1 and a central composite design were employed for microextraction optimization. Under optimized conditions, the developed method was a fast and straightforward approach. Only 250 µl of urine sample was needed, and no hydrolysis was required. The sample pretreatment included only dilution and centrifugation steps (8 min), whereas the complete IT-SPME-LC-MS/MS method took another 12 min, with a sample throughput of 3 samples h-1 . The developed method presented adequate precision, accuracy and linearity; R2 values ranged from 0.990 to 0.997, in the range of 10-1000 ng ml-1 . The lower limits of quantification varied from 10 to 25 ng ml-1 . Finally, the method was successfully applied to analyze 20 actual urine samples, and the IT-SPME microcolumn was reused over 150 times.
Collapse
Affiliation(s)
| | - Jose Luiz Costa
- Faculty of Pharmaceutical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| | - Fernando Mauro Lanças
- São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | | |
Collapse
|
17
|
Magnetic restricted-access carbon nanotubes for SPME to determine cannabinoids in plasma samples by UHPLC-MS/MS. Anal Chim Acta 2022; 1226:340160. [DOI: 10.1016/j.aca.2022.340160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 11/20/2022]
|
18
|
Song Z, Li J, Lu W, Li B, Yang G, Bi Y, Arabi M, Wang X, Ma J, Chen L. Molecularly imprinted polymers based materials and their applications in chromatographic and electrophoretic separations. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2021.116504] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
19
|
Simplified miniaturized analytical set-up based on molecularly imprinted polymer directly coupled to UV detection for the determination of benzoylecgonine in urine. Talanta 2021; 233:122611. [PMID: 34215095 DOI: 10.1016/j.talanta.2021.122611] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 06/09/2021] [Accepted: 06/10/2021] [Indexed: 02/03/2023]
Abstract
A simple, selective, and sensitive method involving a miniaturized solid phase extraction step based on a monolithic molecularly imprinted polymer (MIP) directly coupled on-line to UV detection was developed for the determination of benzoylecgonine (BZE) in complex biological samples. Monolithic MIPs were prepared into 100 μm internal diameter fused-silica capillaries either by thermal or photopolymerization. While leading to similar selectivities with respect to BZE, photopolymerization has made it possible to produce monoliths of different lengths that can be adapted to the targeted miniaturized application. The homogeneous morphology of these monolithic MIPs was evaluated by scanning electron microscopy prior to measuring their permeability. Their selectivity was evaluated leading to imprinting factors of 2.7 ± 0.1 for BZE and 4.0 ± 0.6 for cocaine (selected as template for the MIP synthesis) with polymers resulting from three independent syntheses, showing both the high selectivity of the MIPs and the reproducibility of their synthesis. After selecting the appropriate capillary length and the set-up configuration and optimizing the extraction protocol to promote selectivity, the extraction of BZE present in human urine samples spiked at 150, 250, and 500 ng mL-1 was successfully carried out on the monolithic MIP and coupled directly on-line with UV detection. The very clean-baseline of the resulting chromatograms revealing only the peak of interest for BZE illustrated the high selectivity brought by the monolithic MIP. Limits of detection and quantification of 56.4 ng mL-1 and 188.0 ng mL-1 were achieved in urine samples, respectively. It is therefore possible to achieve analytical threshold in accordance with the legislation on BZE detection in urine without the need for an additional chromatographic separation.
Collapse
|
20
|
Hu W, Zhou W, Wang C, Liu Z, Chen Z. Rapid Analysis of Biological Samples Using Monolithic Polymer-Based In-Tube Solid-Phase Microextraction with Direct Mass Spectrometry. ACS APPLIED BIO MATERIALS 2021; 4:6236-6243. [DOI: 10.1021/acsabm.1c00551] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Wei Hu
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 100080, China
| | - Wei Zhou
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 100080, China
| | - Chenlu Wang
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
| | - Zichun Liu
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
| | - Zilin Chen
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 100080, China
| |
Collapse
|
21
|
Salve S, Bahiram Y, Jadhav A, Rathod R, Tekade RK. Nanoplatform-Integrated Miniaturized Solid-Phase Extraction Techniques: A Critical Review. Crit Rev Anal Chem 2021; 53:46-68. [PMID: 34096402 DOI: 10.1080/10408347.2021.1934651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Preparation of the biological samples is one of the most critical steps in sample analysis. In past decades, the liquid-liquid extraction technique has been used to extract the desired analytes from complex biological matrices. However, solid-phase extraction (SPE) gained popularity due to versatility, simplicity, selectivity, reproducibility, high sample recovery %, solvent economy, and time-saving nature. The superior extraction efficiency of SPE can be attributed to the development of advanced techniques, including the nanosorbents technology. The nanosorbent technology significantly simplified the sample preparation, improved the selectivity, diversified the application, and accelerated the sample analysis. This review critically expands on the to-date advancements reported in SPE with particular regards to the nanosorbent technology.
Collapse
Affiliation(s)
- Sushmita Salve
- National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, Gandhinagar, Gujarat, India
| | - Yogita Bahiram
- National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, Gandhinagar, Gujarat, India
| | - Amol Jadhav
- National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, Gandhinagar, Gujarat, India
| | - Rajeshwari Rathod
- National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, Gandhinagar, Gujarat, India
| | - Rakesh Kumar Tekade
- National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, Gandhinagar, Gujarat, India
| |
Collapse
|
22
|
Grecco CF, Souza ID, Queiroz MEC. Novel materials as capillary coatings for in‐tube solid‐phase microextraction for bioanalysis. J Sep Sci 2021; 44:1662-1693. [DOI: 10.1002/jssc.202001070] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 01/11/2021] [Accepted: 01/31/2021] [Indexed: 12/18/2022]
Affiliation(s)
- Caroline Fernandes Grecco
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| | - Israel Donizeti Souza
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| | - Maria Eugênia Costa Queiroz
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| |
Collapse
|
23
|
Preparation of Polyacrylonitrile/Ni-MOF electrospun nanofiber as an efficient fiber coating material for headspace solid-phase microextraction of diazinon and chlorpyrifos followed by CD-IMS analysis. Food Chem 2021; 350:129242. [PMID: 33626398 DOI: 10.1016/j.foodchem.2021.129242] [Citation(s) in RCA: 50] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Revised: 01/25/2021] [Accepted: 01/27/2021] [Indexed: 12/16/2022]
Abstract
Herein, an electrospun polyacrylonitrile/nickel-based metal-organic framework nanocomposite (PAN/Ni-MOF) coating on a stainless steel wire was synthesized and employed as a novel nanosorbent for headspace solid-phase microextraction (HS-SPME) of organophosphorus pesticides (OPPs), diazinon (DIZ), and chlorpyrifos (CPS) from the diverse aqueous media followed by corona discharge ion mobility spectrometry (CD-IMS). Under the optimum experimental conditions, the calibration plots were linear in the range of 1.0-250.0 ng mL-1 for DIZ and 0.5-300.0 ng mL-1 for CPS with r2 > 0.999. The detection limits (S/N = 3) were 0.3 and 0.2 ng mL-1 for DIZ and CPS, respectively. The intra-day relative standard deviations (RSDs%) (n = 5) at the concentration levels of 20.0, 40.0, and 100.0 ng mL-1 were ≤ 5.2%. To investigate the extraction efficiency, PAN/Ni-MOF was employed to analyze various juice samples, including orange, apple, and grape juices, and in three water samples where it led to good recoveries ranged between 87% and 98%.
Collapse
|
24
|
Bouvarel T, Delaunay N, Pichon V. Molecularly imprinted polymers in miniaturized extraction and separation devices. J Sep Sci 2021; 44:1727-1751. [DOI: 10.1002/jssc.202001223] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 01/18/2021] [Accepted: 01/20/2021] [Indexed: 12/20/2022]
Affiliation(s)
- Thomas Bouvarel
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation—UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS PSL University Paris 75005 France
| | - Nathalie Delaunay
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation—UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS PSL University Paris 75005 France
| | - Valérie Pichon
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation—UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS PSL University Paris 75005 France
- Sorbonne Université Paris 75005 France
| |
Collapse
|
25
|
Cruz JC, Miranda LFC, Queiroz MEC. Pipette tip micro-solid phase extraction (octyl-functionalized hybrid silica monolith) and ultra-high-performance liquid chromatography-tandem mass spectrometry to determine cannabidiol and tetrahydrocannabinol in plasma samples. J Sep Sci 2021; 44:1621-1632. [PMID: 33387419 DOI: 10.1002/jssc.202000906] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 12/25/2020] [Accepted: 12/30/2020] [Indexed: 11/08/2022]
Abstract
This manuscript describes the development of an innovative method to determine cannabinoids (cannabidiol and tetrahydrocannabinol) in human plasma samples by pipette tip micro-solid phase extraction and liquid chromatography-mass spectrometry/mass spectromtery. An octyl-functionalized hybrid silica monolith, which had been synthesized and characterized, was used as a selective stationary phase. The octyl-functionalized hybrid silica monoliths presented high permeability and adequate mechanical strength. The micro-solid phase extraction variables (sample pH, draw-eject cycles, solvent for phase clean-up, and desorption conditions) were investigated to improve not only the selectivity but also the sorption capacity. The method was linear at concentrations ranging from the lower limit of quantification (10.00 ng/mL) to the upper limit of quantification (150.0 ng/mL). The lack of fit and homoscedasticity tests, as well as the determination coefficients (r2 greater than 0.995), certified that linearity was adequate. The precision assays presented coefficient of variation values lower than 15%, and the accuracy tests provided relative error values ranging from 3.2 to 14%. Neither significant carry-over nor matrix effects were detected. Therefore, the pipette tip micro-solid phase extraction/liquid chromatography-mass spectrometry/mass spectrometry method has demonstrated to be adequate to determine cannabidiol and tetrahydrocannabinol simultaneously in plasma samples for therapeutic drug monitoring of patients undergoing treatment with cannabinoids.
Collapse
Affiliation(s)
- Jonas Carneiro Cruz
- Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, São Paulo, Brazil
| | - Luís Felippe Cabral Miranda
- Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, São Paulo, Brazil
| | - Maria Eugênia Costa Queiroz
- Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, São Paulo, Brazil
| |
Collapse
|
26
|
Kataoka H. In-tube solid-phase microextraction: Current trends and future perspectives. J Chromatogr A 2020; 1636:461787. [PMID: 33359971 DOI: 10.1016/j.chroma.2020.461787] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 12/02/2020] [Accepted: 12/04/2020] [Indexed: 01/01/2023]
Abstract
In-tube solid-phase microextraction (IT-SPME) was developed about 24 years ago as an effective sample preparation technique using an open tubular capillary column as an extraction device. IT-SPME is useful for micro-concentration, automated sample cleanup, and rapid online analysis, and can be used to determine the analytes in complex matrices simple sample processing methods such as direct sample injection or filtration. IT-SPME is usually performed in combination with high-performance liquid chromatography using an online column switching technology, in which the entire process from sample preparation to separation to data analysis is automated using the autosampler. Furthermore, IT-SPME minimizes the use of harmful organic solvents and is simple and labor-saving, making it a sustainable and environmentally friendly green analytical technique. Various operating systems and new sorbent materials have been developed to improve its extraction efficiency by, for example, enhancing its sorption capacity and selectivity. In addition, IT-SPME methods have been widely applied in environmental analysis, food analysis and bioanalysis. This review describes the present state of IT-SPME technology and summarizes its current trends and future perspectives, including method development and strategies to improve extraction efficiency.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan.
| |
Collapse
|
27
|
Tomai P, Gentili A, Curini R, Gottardo R, Franco Tagliaro, Fanali S. Dispersive liquid-liquid microextraction, an effective tool for the determination of synthetic cannabinoids in oral fluid by liquid chromatography-tandem mass spectrometry. J Pharm Anal 2020; 11:292-298. [PMID: 34277117 PMCID: PMC8264461 DOI: 10.1016/j.jpha.2020.11.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 11/12/2020] [Accepted: 11/16/2020] [Indexed: 11/16/2022] Open
Abstract
In the present work, dispersive liquid-liquid microextraction (DLLME) was used to extract six synthetic cannabinoids (JWH-018, JWH-019, JWH-073, JWH-200, or WIN 55,225, JWH-250, and AM-694) from oral fluids. A rapid baseline separation of the analytes was achieved on a bidentate octadecyl silica hydride phase (Cogent Bidentate C18; 4.6 mm × 250 mm, 4 μm) maintained at 37 °C, by eluting in isocratic conditions (water:acetonitrile (25:75, V/V)). Detection was performed using positive electrospray ionization-tandem mass spectrometry. The parameters affecting DLLME (pH and ionic strength of the aqueous phase, type and volume of the extractant and dispersive solvent, vortex and centrifugation time) were optimized for maximizing yields. In particular, using 0.5 mL of oral fluid, acetonitrile (1 mL), was identified as the best option, both as a solvent to precipitate proteins and as a dispersing solvent in the DLLME procedure. To select an extraction solvent, a low transition temperature mixture (LTTM; composed of sesamol and chlorine chloride with a molar ratio of 1:3) and dichloromethane were compared; the latter (100 μL) was proved to be a better extractant, with recoveries ranging from 73% to 101 % by vortexing for 2 min. The method was validated according to the guidelines of Food and Drug Administration bioanalytical methods: intra-day and inter-day precisions ranged between 4 % and 18 % depending on the spike level and analyte; limits of detection spanned from 2 to 18 ng/mL; matrix-matched calibration curves were characterized by determination coefficients greater than 0.9914. Finally, the extraction procedure was compared with previous methods and with innovative techniques, presenting superior reliability, rapidity, simplicity, inexpensiveness, and efficiency.
Collapse
Affiliation(s)
- Pierpaolo Tomai
- Department of Chemistry, Sapienza University, P.le Aldo Moro 5, 00185, Rome, Italy
| | - Alessandra Gentili
- Department of Chemistry, Sapienza University, P.le Aldo Moro 5, 00185, Rome, Italy
| | - Roberta Curini
- Department of Chemistry, Sapienza University, P.le Aldo Moro 5, 00185, Rome, Italy
| | - Rossella Gottardo
- Department of Diagnostics and Public Health, University of Verona, Verona, Italy and Institute of Translational Medicine and Biotechnology, Sechenov First Moscow State Medical University, Moscow, Russia
| | - Franco Tagliaro
- Department of Diagnostics and Public Health, University of Verona, Verona, Italy and Institute of Translational Medicine and Biotechnology, Sechenov First Moscow State Medical University, Moscow, Russia
| | - Salvatore Fanali
- Teaching Committee of Ph.D. School in Natural Science and Engineering University of Verona, Verona, Italy
| |
Collapse
|
28
|
Fang S, Liu Y, He J, Zhang L, Liyin Z, Wu X, Sun H, Lai J. Determination of aldehydes in water samples by coupling magnetism-reinforced molecular imprinting monolith microextraction and non-aqueous capillary electrophoresis. J Chromatogr A 2020; 1632:461602. [DOI: 10.1016/j.chroma.2020.461602] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Revised: 10/06/2020] [Accepted: 10/07/2020] [Indexed: 12/11/2022]
|
29
|
Brighenti V, Protti M, Anceschi L, Zanardi C, Mercolini L, Pellati F. Emerging challenges in the extraction, analysis and bioanalysis of cannabidiol and related compounds. J Pharm Biomed Anal 2020; 192:113633. [PMID: 33039911 DOI: 10.1016/j.jpba.2020.113633] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 09/08/2020] [Accepted: 09/09/2020] [Indexed: 02/07/2023]
Abstract
Cannabidiol (CBD) is a bioactive terpenophenolic compound isolated from Cannabis sativa L. It is known to possess several properties of pharmaceutical interest, such as antioxidant, anti-inflammatory, anti-microbial, neuroprotective and anti-convulsant, being it active as a multi-target compound. From a therapeutic point of view, CBD is most commonly used for seizure disorder in children. CBD is present in both medical and fiber-type C. sativa plants, but, unlike Δ9-tetrahydrocannabinol (THC), it is a non-psychoactive compound. Non-psychoactive or fiber-type C. sativa (also known as hemp) differs from the medical one, since it contains only low levels of THC and high levels of CBD and related non-psychoactive cannabinoids. In addition to medical Cannabis, which is used for many different therapeutic purposes, a great expansion of the market of hemp plant material and related products has been observed in recent years, due to its usage in many fields, including food, cosmetics and electronic cigarettes liquids (commonly known as e-liquids). In this view, this work is focused on recent advances on sample preparation strategies and analytical methods for the chemical analysis of CBD and related compounds in both C. sativa plant material, its derived products and biological samples. Since sample preparation is considered to be a crucial step in the development of reliable analytical methods for the determination of natural compounds in complex matrices, different extraction methods are discussed. As regards the analysis of CBD and related compounds, the application of both separation and non-separation methods is discussed in detail. The advantages, disadvantages and applicability of the different methodologies currently available are evaluated. The scientific interest in the development of portable devices for the reliable analysis of CBD in vegetable and biological samples is also highlighted.
Collapse
Affiliation(s)
- Virginia Brighenti
- Department of Life Sciences, University of Modena and Reggio Emilia, Via G. Campi 103, 41125 Modena, Italy
| | - Michele Protti
- Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy
| | - Lisa Anceschi
- Department of Life Sciences, University of Modena and Reggio Emilia, Via G. Campi 103, 41125 Modena, Italy; Doctorate School in Clinical and Experimental Medicine (CEM), University of Modena and Reggio Emilia, Via G. Campi 103/287, 41125 Modena, Italy
| | - Chiara Zanardi
- Department of Chemical and Geological Sciences, University of Modena and Reggio Emilia, Via G. Campi 103, 41125 Modena, Italy
| | - Laura Mercolini
- Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy.
| | - Federica Pellati
- Department of Life Sciences, University of Modena and Reggio Emilia, Via G. Campi 103, 41125 Modena, Italy.
| |
Collapse
|
30
|
Manousi N, Tzanavaras PD, Zacharis CK. Bioanalytical HPLC Applications of In-Tube Solid Phase Microextraction: A Two-Decade Overview. Molecules 2020; 25:molecules25092096. [PMID: 32365828 PMCID: PMC7248733 DOI: 10.3390/molecules25092096] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 12/18/2022] Open
Abstract
In-tube solid phase microextraction is a cutting-edge sample treatment technique offering significant advantages in terms of miniaturization, green character, automation, and preconcentration prior to analysis. During the past years, there has been a considerable increase in the reported publications, as well as in the research groups focusing their activities on this technique. In the present review article, HPLC bioanalytical applications of in-tube SPME are discussed, covering a wide time frame of twenty years of research reports. Instrumental aspects towards the coupling of in-tube SPME and HPLC are also discussed, and detailed information on materials/coatings and applications in biological samples are provided.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Paraskevas D. Tzanavaras
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Constantinos K. Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
- Correspondence: ; Tel.: +30-231-099-7663
| |
Collapse
|