1
|
Chen X, Xu J, Zhang L, Bi N, Gou J, Li Y, Zhao T, Jia L. A sensitive fluorometric-colorimetric dual-mode intelligent sensing platform for the detection of formaldehyde. Food Chem 2024; 439:138095. [PMID: 38039616 DOI: 10.1016/j.foodchem.2023.138095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/13/2023] [Accepted: 11/25/2023] [Indexed: 12/03/2023]
Abstract
Excess formaldehyde (FA) is a strong carcinogen, so the development of a rapid visualized and portable formaldehyde detection platform is of great research importance. A multi-color fluorescence sensing system constituted of model compound (NAHN) and red-emitting InP/ZnS QDs was constructed herein, which can simultaneously realize fluorometric-colorimetric dual-mode sensing when exposed to FA environment. Its preparation process was simplified, the detection process was green, and the limits of detection (LOD) were 0.623 μM and 0.791 μM, respectively. The high recoveries of FA in actual water samples indicated that the sensor had broad application prospects. The prepared fluorescent film can be utilized for rapid visual simulation analysis of FA on the surface of various fruits and vegetables. In addition, a serial logic gate was designed to quickly semi-quantitatively assess FA concentration, which promoted the realization of on-site intelligent evaluation of FA.
Collapse
Affiliation(s)
- Xiangzhen Chen
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo, Henan 454000, China
| | - Jun Xu
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo, Henan 454000, China.
| | - Lina Zhang
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo, Henan 454000, China
| | - Ning Bi
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo, Henan 454000, China
| | - Jian Gou
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo, Henan 454000, China
| | - Yongxin Li
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo, Henan 454000, China
| | - Tongqian Zhao
- Institute of Resources & Environment, Henan Polytechnic University, Jiaozuo, Henan 454000, China.
| | - Lei Jia
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo, Henan 454000, China.
| |
Collapse
|
2
|
Park G, Jang M, Han MS. A fluorous-tag-assisted fluorescent probe for simple and selective detection of hydrogen sulfide: application for turbid dyeing solutions. RSC Adv 2023; 13:32137-32142. [PMID: 37928855 PMCID: PMC10620642 DOI: 10.1039/d3ra06740h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 10/20/2023] [Indexed: 11/07/2023] Open
Abstract
Accurate hydrogen sulfide (H2S) detection has attracted much attention because its toxicity may affect aquatic environments and human health. However, recognizing H2S levels by conventional fluorescent probes in turbid wastewater has been challenging because the opaque environment interferes with their photophysical properties. To overcome this limitation, a fluorous-tagging strategy can be used for the development of fluorescent sensors to detect H2S in turbid solutions. The use of fluorescent probe assisted with fluorous-tag allowed for easy isolation of the probe using polytetrafluoroethylene (PTFE) material, while disturbing species were eliminated through a simple aqueous wash. This approach enabled the fluorescent probe to effectively quantify H2S, even in opaque solutions containing organic dyes that could interfere with fluorescence emission.
Collapse
Affiliation(s)
- Geonwoo Park
- Department of Chemistry, Gwangju Institute of Science and Technology (GIST) 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
| | - Mincheol Jang
- Department of Chemistry, Gwangju Institute of Science and Technology (GIST) 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
| | - Min Su Han
- Department of Chemistry, Gwangju Institute of Science and Technology (GIST) 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
| |
Collapse
|
3
|
Saiboh T, Malahom N, Prakobkij A, Seebunrueng K, Amatatongchai M, Chairam S, Sameenoi Y, Jarujamrus P. Visual detection of formalin in food samples by using a microfluidic thread-based analytical device. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
|
4
|
Recent advances in colorimetric and fluorometric sensing of neurotransmitters by organic scaffolds. Eur J Med Chem 2022; 244:114820. [DOI: 10.1016/j.ejmech.2022.114820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 09/22/2022] [Accepted: 09/30/2022] [Indexed: 11/22/2022]
|
5
|
Pérez-Rodríguez M, Cañizares-Macías MDP. A prototype microfluidic paper-based chromatic device for simultaneous determination of copper(II) and zinc(II) in urine. TALANTA OPEN 2022. [DOI: 10.1016/j.talo.2022.100178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
|
6
|
Tasangtong B, Henry CS, Sameenoi Y. Diameter-based inkjet-printed paper devices for formaldehyde analysis in foods. Food Control 2022. [DOI: 10.1016/j.foodcont.2022.109408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
7
|
Villarino N, Pena-Pereira F, Lavilla I, Bendicho C. Waterproof Cellulose-Based Substrates for In-Drop Plasmonic Colorimetric Sensing of Volatiles: Application to Acid-Labile Sulfide Determination in Waters. ACS Sens 2022; 7:839-848. [PMID: 35285629 PMCID: PMC8961881 DOI: 10.1021/acssensors.1c02585] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The present work reports on the assessment of widely available waterproof cellulose-based substrates for the development of sensitive in-drop plasmonic sensing approaches. The applicability of three inexpensive substrates, namely, Whatman 1PS, polyethylene-coated filter paper, and tracing paper, as holders for microvolumes of colloidal solutions was evaluated. Waterproof cellulose-based substrates demonstrated to be highly convenient platforms for analytical purposes, as they enabled in situ generation of volatiles and syringeless drop exposure unlike conventional single-drop microextraction approaches and can behave as sample compartments for smartphone-based colorimetric sensing in an integrated way. Remarkably, large drop volumes (≥20 μL) of colloidal solutions can be employed for enrichment processes when using Whatman 1PS as holder. In addition, the stability and potential applicability of spherical, rod-shaped, and core-shell metallic NPs onto waterproof cellulose-based substrates was evaluated. In particular, Au@AgNPs showed potential for the colorimetric detection of in situ generated H2S, I2, and Br2, whereas AuNRs hold promise for I2, Br2, and Hg0 colorimetric sensing. As a proof of concept, a smartphone-based colorimetric assay for determination of acid-labile sulfide in environmental water samples was developed with the proposed approach taking advantage of the ability of Au@AgNPs for H2S sensing. The assay showed a limit of detection of 0.46 μM and a repeatability of 4.4% (N = 8), yielding satisfactory recoveries (91-107%) when applied to the analysis of environmental waters.
Collapse
Affiliation(s)
- Nerea Villarino
- Centro de Investigación Mariña, Universidade de Vigo, Departamento de Química Analítica e alimentaria, Grupo QA2, Edificio CC Experimentais, Campus de Vigo, As Lagoas, Marcosende, 36310 Vigo, Spain
| | - Francisco Pena-Pereira
- Centro de Investigación Mariña, Universidade de Vigo, Departamento de Química Analítica e alimentaria, Grupo QA2, Edificio CC Experimentais, Campus de Vigo, As Lagoas, Marcosende, 36310 Vigo, Spain
| | - Isela Lavilla
- Centro de Investigación Mariña, Universidade de Vigo, Departamento de Química Analítica e alimentaria, Grupo QA2, Edificio CC Experimentais, Campus de Vigo, As Lagoas, Marcosende, 36310 Vigo, Spain
| | - Carlos Bendicho
- Centro de Investigación Mariña, Universidade de Vigo, Departamento de Química Analítica e alimentaria, Grupo QA2, Edificio CC Experimentais, Campus de Vigo, As Lagoas, Marcosende, 36310 Vigo, Spain
| |
Collapse
|
8
|
Pongkitdachoti U, Unob F. Silver-doped hydroxyapatite for formaldehyde determination by digital-image colorimetry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:926-934. [PMID: 35167629 DOI: 10.1039/d1ay02031e] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Silver-hydroxyapatite material (Ag-HAP) was first proposed as material for trace-level formaldehyde detection based on Tollens' reaction on the material surface. By using this Ag-HAP material, the chemical reduction caused by formaldehyde occurred directly on the solid surface. The material color changed from off-white to the yellow or brown of silver nanoparticles depending on the formaldehyde concentration. The color intensity of the materials was measured from their smartphone digital images using Image-J software. The effect of silver ion concentration, sodium hydroxide concentration, contact time, and sample volume on formaldehyde detection were investigated. Under optimized conditions, the working range for formaldehyde detection was determined to be 15 to 200 μg L-1. The method was successfully applied to detect trace formaldehyde in water samples and a recovery of 86 to 111%, with an RSD of 3 to 8%, was observed. With a lowest concentration for the detection of 15 μg L-1 and good accuracy and precision, the method showed promise for formaldehyde determination.
Collapse
Affiliation(s)
- Uma Pongkitdachoti
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
| | - Fuangfa Unob
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
| |
Collapse
|
9
|
Development of a Screening Method for Sulfamethoxazole in Environmental Water by Digital Colorimetry Using a Mobile Device. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10010025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Antibiotic resistance is a major health concern of the 21st century. The misuse of antibiotics over the years has led to their increasing presence in the environment, particularly in water resources, which can exacerbate the transmission of resistance genes and facilitate the emergence of resistant microorganisms. The objective of the present work is to develop a chemosensor for screening of sulfonamides in environmental waters, targeting sulfamethoxazole as the model analyte. The methodology was based on the retention of sulfamethoxazole in disks containing polystyrene divinylbenzene sulfonated sorbent particles and reaction with p-dimethylaminocinnamaldehyde, followed by colorimetric detection using a computer-vision algorithm. Several color spaces (RGB, HSV and CIELAB) were evaluated, with the coordinate a_star, from the CIELAB color space, providing the highest sensitivity. Moreover, in order to avoid possible errors due to variations in illumination, a color palette is included in the picture of the analytical disk, and a correction using the a_star value from one of the color patches is proposed. The methodology presented recoveries of 82–101% at 0.1 µg and 0.5 µg of sulfamethoxazole (25 mL), providing a detection limit of 0.08 µg and a quantification limit of 0.26 µg. As a proof of concept, application to in-field analysis was successfully implemented.
Collapse
|
10
|
Khaleghi H, Esmaeili H, Jaafarzadeh N, Ramavandi B. Date seed activated carbon decorated with CaO and Fe3O4 nanoparticles as a reusable sorbent for removal of formaldehyde. KOREAN J CHEM ENG 2022. [DOI: 10.1007/s11814-021-0972-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
11
|
Doménech-Carbó MT, Doménech-Carbó A. Spot tests: past and present. CHEMTEXTS 2022; 8:4. [PMID: 34976574 PMCID: PMC8710564 DOI: 10.1007/s40828-021-00152-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 10/11/2021] [Indexed: 11/21/2022]
Abstract
Microchemistry, i.e., the chemistry performed at the scale of a microgram or less, has its roots in the late eighteenth and early nineteenth centuries. In the first half of the twentieth century a wide range of spot tests have been developed. For didactic reasons, they are still part of the curriculum of chemistry students. However, they are even highly important for applied analyses in conservation of cultural heritage, food science, forensic science, clinical and pharmacological sciences, geochemistry, and environmental sciences. Modern pregnancy tests, virus tests, etc. are the most recent examples of sophisticated spot tests. The present ChemTexts contribution aims to provide an overview of the past and present of this analytical methodology.
Collapse
Affiliation(s)
- María Teresa Doménech-Carbó
- Institut de Restauració del Patrimoni, Universitat Politècnica de València, Camí de Vera 14, 46022 Valencia, Spain
| | - Antonio Doménech-Carbó
- Departament de Química Analítica, Universitat de València. Dr. Moliner, 50, Burjassot, 46100 Valencia, Spain
| |
Collapse
|
12
|
Li J, Gong JL, Zeng GM, Song B, Cao WC, Fang SY, Tang SQ, Guan Y, Tan ZK, Chen ZP, Mao XQ, Zhu RL. Thin-film composite polyester nanofiltration membrane with high flux and efficient dye/salts separation fabricated from precise molecular sieving structure of β-cyclodextrin. Sep Purif Technol 2021. [DOI: 10.1016/j.seppur.2021.119352] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
13
|
Kishnani V, Park S, Nakate UT, Mondal K, Gupta A. Nano-functionalized paper-based IoT enabled devices for point-of-care testing: a review. Biomed Microdevices 2021; 24:2. [PMID: 34792679 PMCID: PMC8600500 DOI: 10.1007/s10544-021-00588-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/20/2021] [Indexed: 11/04/2022]
Abstract
Over the last few years, the microfluidics phenomenon coupled with the Internet of Things (IoT) using innovative nano-functional materials has been recognized as a sustainable and economical tool for point-of-care testing (POCT) of various pathogens influencing human health. The sensors based on these phenomena aim to be designed for cost-effectiveness, make it handy, environment-friendly, and get an accurate, easy, and rapid response. Considering the burgeoning importance of analytical devices in the healthcare domain, this review paper is based on the gist of sensing aspects of the microfabricated paper-based analytical devices (μPADs). The article discusses the various used design methodologies and fabrication approaches and elucidates the recently reported surface modification strategies, detection mechanisms viz., colorimetric, electrochemical, fluorescence, electrochemiluminescence, etc. In a nutshell, this article summarizes the state-of-the-art research work carried out over the nano functionalized paper-based analytical devices and associated challenges/solutions in the point of care testing domain.
Collapse
Affiliation(s)
- Vinay Kishnani
- Department of Mechanical Engineering, Indian Institute of Technology Jodhpur-342037, Rajasthan, India
| | - Sungjune Park
- Department of Polymer Nano Science and Technology, Jeonbuk National University, Jeonju, 54896, South Korea
| | - Umesh T Nakate
- Department of Polymer Nano Science and Technology, Jeonbuk National University, Jeonju, 54896, South Korea
| | - Kunal Mondal
- Materials Science and Engineering Department, Idaho National Laboratory, Idaho Falls, ID 83415, USA
| | - Ankur Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Jodhpur-342037, Rajasthan, India.
| |
Collapse
|
14
|
Che H, Li Y, Tian X, Yang C, Lu L, Nie Y. A versatile logic detector and fluorescent film based on Eu-based MOF for swift detection of formaldehyde in solutions and gas phase. JOURNAL OF HAZARDOUS MATERIALS 2021; 410:124624. [PMID: 33243644 DOI: 10.1016/j.jhazmat.2020.124624] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 11/05/2020] [Accepted: 11/16/2020] [Indexed: 06/11/2023]
Abstract
Due to the huge threat of formaldehyde (FA) on human beings, the development of chemical sensors for swift detection of FA in solutions and gas phase is highly anticipated. In this paper, a versatile logic detector and a portable fluorescent film based on small-scaled Eu-based MOF were applied successfully to detect FA in solutions and gas phase, respectively. For FA in aqueous solution, the design of logic detector will efficiently identify FA in different concentration ranges: when the FA concentration are 0-500 ppb, 500-1000 ppb and >1000 ppb, the output signals of logic detector are the concentration level of FA ("L", "H" and "VH"), and accompanied by red, purple and blue signal lamps to remind, respectively. For FA in the air, the color of rigid film sensor will gradually change from red to blue with the increase of FA under UV lamp, and the detection limit of gaseous FA is 11.8 ppb. Through the preparation of logic devices and fluorescent films, Eu-based MOF realized swift detection of FA in solutions and gas phase, which will be very helpful to improve the human response level to FA from different emission sources.
Collapse
Affiliation(s)
- Huachao Che
- Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Yong Li
- Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xike Tian
- Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Chao Yang
- Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Liqiang Lu
- Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Yulun Nie
- Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China.
| |
Collapse
|
15
|
Use of universal 3D-Printed smartphone spectrophotometer to develop a time-based analysis for hypochlorite. Anal Chim Acta 2021; 1151:338249. [PMID: 33608080 DOI: 10.1016/j.aca.2021.338249] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 01/13/2021] [Accepted: 01/19/2021] [Indexed: 12/18/2022]
Abstract
A fully-functional smartphone-based spectrophotometer was designed and built using 3D printing. The major advantage of this approach is its capacity to be interfaced with a variety of smartphones, allowing the use of the smartphone's camera and display, and regardless of the relative position of the camera. The analytical performance of the device was analyzed using a model dye (crystal violet), leading to a proportional response for concentrations in the 0.06-15.0 mg L-1 range, with a variability of 1.0% (intra-day) and 2.6% (inter-day). To demonstrate the functionality of the device, the degradation process of the dye by sodium hypochlorite was studied. The results obtained were applied to develop a paper-based test for NaClO in sanitation solutions, in which the time required to bleach the dye was used to estimate the concentration of the solution. This device represents a simple and inexpensive tool for everyday laboratory use and could address important analytical challenges in low-income communities and features a versatile arrangement, that is compatible with a wide variety of smartphones and software platforms.
Collapse
|