1
|
Skotadis E, Aslanidis E, Tsekenis G, Panagopoulou C, Rapesi A, Tzourmana G, Kennou S, Ladas S, Zeniou A, Tsoukalas D. Hybrid Nanoparticle/DNAzyme Electrochemical Biosensor for the Detection of Divalent Heavy Metal Ions and Cr 3. SENSORS (BASEL, SWITZERLAND) 2023; 23:7818. [PMID: 37765875 PMCID: PMC10535422 DOI: 10.3390/s23187818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 08/30/2023] [Accepted: 09/10/2023] [Indexed: 09/29/2023]
Abstract
A hybrid noble nanoparticle/DNAzyme electrochemical biosensor is proposed for the detection of Pb2+, Cd2+, and Cr3+. The sensor takes advantage of a well-studied material that is known for its selective interaction with heavy metal ions (i.e., DNAzymes), which is combined with metallic nanoparticles. The double-helix structure of DNAzymes is known to dissociate into smaller fragments in the presence of specific heavy metal ions; this results in a measurable change in device resistance due to the collapse of conductive inter-nanoparticle DNAzyme bridging. The paper discusses the effect of DNAzyme anchoring groups (i.e., thiol and amino functionalization groups) on device performance and reports on the successful detection of all three target ions in concentrations that are well below their maximum permitted levels in tap water. While the use of DNAzymes for the detection of lead in particular and, to some extent, cadmium has been studied extensively, this is one of the few reports on the successful detection of chromium (III) via a sensor incorporating DNAzymes. The sensor showed great potential for its future integration in autonomous and remote sensing systems due to its low power characteristics, simple and cost-effective fabrication, and easy automation and measurement.
Collapse
Affiliation(s)
- Evangelos Skotadis
- Department of Applied Physics, National Technical University of Athens, 15780 Athens, Greece; (E.A.); (C.P.); (A.R.); (G.T.); (D.T.)
| | - Evangelos Aslanidis
- Department of Applied Physics, National Technical University of Athens, 15780 Athens, Greece; (E.A.); (C.P.); (A.R.); (G.T.); (D.T.)
| | - Georgios Tsekenis
- Biomedical Research Foundation, Academy of Athens, 4 Soranou Ephessiou Street, 11527 Athens, Greece;
| | - Chryssi Panagopoulou
- Department of Applied Physics, National Technical University of Athens, 15780 Athens, Greece; (E.A.); (C.P.); (A.R.); (G.T.); (D.T.)
| | - Annita Rapesi
- Department of Applied Physics, National Technical University of Athens, 15780 Athens, Greece; (E.A.); (C.P.); (A.R.); (G.T.); (D.T.)
| | - Georgia Tzourmana
- Department of Applied Physics, National Technical University of Athens, 15780 Athens, Greece; (E.A.); (C.P.); (A.R.); (G.T.); (D.T.)
| | - Stella Kennou
- Department of Chemical Engineering, University of Patras, 26504 Patras, Greece; (S.K.); (S.L.)
| | - Spyridon Ladas
- Department of Chemical Engineering, University of Patras, 26504 Patras, Greece; (S.K.); (S.L.)
| | - Angelos Zeniou
- Institute of Nanoscience and Nanotechnology, NCSR Demokritos, Aghia Paraskevi, 15310 Attiki, Greece;
| | - Dimitris Tsoukalas
- Department of Applied Physics, National Technical University of Athens, 15780 Athens, Greece; (E.A.); (C.P.); (A.R.); (G.T.); (D.T.)
| |
Collapse
|
2
|
Liu L, Cui Y, Yang Y, Zhu W, Li C, Fang M. A novel lipid droplets/lysosomes-targeting colorimetric and ratiometric fluorescent probe for Cu 2+ and its application. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 291:122333. [PMID: 36621028 DOI: 10.1016/j.saa.2023.122333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 12/21/2022] [Accepted: 01/03/2023] [Indexed: 06/17/2023]
Abstract
A novel multifunctional fluorescent probe LL2 was prepared via a one-step condensation reaction between 3-formyl-N-butylcarbazole and 2-Hydroxy-1-naphthylhydrazone. LL2 can work as a colorimetric probe for Cu2+, and can also selectively recognize Cu2+ via ratiometric fluorescence signal. After the addition of Cu2+, the probe LL2 responded rapidly within 5 s and reached stability within 30 s. In natural light, when Cu2+ were added to the solution, the color of probe LL2 changed from yellowish to colorless, while there was a discernible fluorescence changed from green to blue under a 365 nm UV lamp. The ratiometric fluorescence intensity (F449/F510) showed a good linear relationship (R2 = 0.9902) with Cu2+ concentration in the concentration range of 0-5 μmol/L, and the minimum detection limit was 1.96 μM. Cell imaging experiments showed that LL2 could capture fluorescence signals in the green and blue channels of HepG2 cells through fluorescence confocal microscope, and successfully recognize exogenous Cu2+ in HepG2 cells. In addition, fluorescence co-localization experiments showed that LL2 could target both lipid droplets and lysosomes. Meanwhile, LL2 could be applied to filter paper strip assay and detection of Cu2+ in actual water samples. These results indicated that probe LL2 has a good capability for monitoring Cu2+ in environment and living cells.
Collapse
Affiliation(s)
- Li Liu
- School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, PR China
| | - Yuanyuan Cui
- School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, PR China
| | - Yixian Yang
- School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, PR China
| | - Weiju Zhu
- School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, PR China; AnHui Province Key Laboratory of Chemistry for Inorganic/Organic Hybrid Functionalized Materials, Anhui University, Hefei 230601, PR China.
| | - Cun Li
- AnHui Province Key Laboratory of Chemistry for Inorganic/Organic Hybrid Functionalized Materials, Anhui University, Hefei 230601, PR China; School of Materials Science and Engineering, Anhui University, Hefei 230601, PR China
| | - Min Fang
- School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, PR China; Anhui Province Key Laboratory of Environment-friendly Polymer Materials, Anhui University, Hefei 230601, PR China.
| |
Collapse
|
3
|
Liu CC, Ko CH, Fu LM, Jhou YL. Light-shading reaction microfluidic PMMA/paper detection system for detection of cyclamate concentration in foods. Food Chem 2023; 400:134063. [DOI: 10.1016/j.foodchem.2022.134063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 08/15/2022] [Accepted: 08/28/2022] [Indexed: 11/17/2022]
|
4
|
Screen-printed electrochemical sensors for environmental monitoring of heavy metal ion detection. REV CHEM ENG 2022. [DOI: 10.1515/revce-2022-0002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
Heavy metal ions (HMIs) are known to cause severe damages to the human body and ecological environment. And considering the current alarming situation, it is crucial to develop a rapid, sensitive, robust, economical and convenient method for their detection. Screen printed electrochemical technology contributes greatly to this task, and has achieved global attention. It enabled the mass transmission rate and demonstrated ability to control the chemical nature of the measure media. Besides, the technique offers advantages like linear output, quick response, high selectivity, sensitivity and stability along with low power requirement and high signal-to-noise ratio. Recently, the performance of SPEs has been improved employing the most effective and promising method of the incorporation of different nanomaterials into SPEs. Especially, in electrochemical sensors, the incorporation of nanomaterials has gained extensive attention for HMIs detection as it exhibits outstanding features like broad electrochemical window, large surface area, high conductivity, selectivity and stability. The present review focuses on the recent progress in the field of screen-printed electrochemical sensors for HMIs detection using nanomaterials. Different fabrication methods of SPEs and their utilization for real sample analysis of HMIs using various nanomaterials have been extensively discussed. Additionally, advancement made in this field is also discussed taking help of the recent literature.
Collapse
|
5
|
Xiang Y, Hu C, Wu G, Xu S, Li Y. Nanomaterial-based microfluidic systems for cancer biomarker detection: Recent applications and future perspectives. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
6
|
Ge S, Li G, Zhou X, Mao Y, Gu Y, Li Z, Gu Y, Cao X. Pump-free microfluidic chip based laryngeal squamous cell carcinoma-related microRNAs detection through the combination of surface-enhanced Raman scattering techniques and catalytic hairpin assembly amplification. Talanta 2022; 245:123478. [DOI: 10.1016/j.talanta.2022.123478] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 04/07/2022] [Accepted: 04/10/2022] [Indexed: 01/14/2023]
|
7
|
Wu M, Wu S, Wang G, Liu W, Chu LT, Jiang T, Kwong HK, Chow HL, Li IWS, Chen TH. Microfluidic particle dam for direct visualization of SARS-CoV-2 antibody levels in COVID-19 vaccinees. SCIENCE ADVANCES 2022; 8:eabn6064. [PMID: 35658040 PMCID: PMC9166397 DOI: 10.1126/sciadv.abn6064] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Various COVID-19 vaccines are currently deployed, but their immunization varies and decays with time. Antibody level is a potent correlate to immune protection, but its quantitation relies on intensive laboratory techniques. Here, we report a decentralized, instrument-free microfluidic device that directly visualizes SARS-CoV-2 antibody levels. Magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) can bind to SARS-CoV-2 antibodies simultaneously. In a microfluidic chip, this binding reduces the incidence of free PMPs escaping from magnetic separation and shortens PMP accumulation length at a particle dam. This visual quantitative result enables use in either sensitive mode [limit of detection (LOD): 13.3 ng/ml; sample-to-answer time: 70 min] or rapid mode (LOD: 57.8 ng/ml; sample-to-answer time: 20 min) and closely agrees with the gold standard enzyme-linked immunosorbent assay. Trials on 91 vaccinees revealed higher antibody levels in mRNA vaccinees than in inactivated vaccinees and their decay in 45 days, demonstrating the need for point-of-care devices to monitor immune protection.
Collapse
Affiliation(s)
- Minghui Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Siying Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Gaobo Wang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Wengang Liu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Lok Ting Chu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Tianyi Jiang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hoi Kwan Kwong
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hiu Lam Chow
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Iris Wai Sum Li
- HKU-Pasteur Research Pole, The University of Hong Kong, Pokfulam, Hong Kong Special Administrative Region, China
| | - Ting-Hsuan Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
- City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
- Corresponding author.
| |
Collapse
|
8
|
Kavitha V, Ramya M, Viswanathamurthi P, Haribabu J, Echeverria C. Design of a dual responsive receptor with oxochromane hydrazide moiety to monitor toxic Hg 2+ and Cd 2+ ions: Usage on real samples and live cells. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2022; 301:119036. [PMID: 35202765 DOI: 10.1016/j.envpol.2022.119036] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 02/10/2022] [Accepted: 02/17/2022] [Indexed: 06/14/2023]
Abstract
In this work, we report a facile receptor OMB [N',N"'-(3-((4-oxochroman-3-yl)methylene)pentane-2,4- diylidene)bis(4-methoxybenzohydrazide)] for the simultaneous detection of toxic analytes (Hg2+ and Cd2+ ions) in environment and biological samples. The receptor OMB exhibits an excellent selectivity and sensitivity which was determined using absorption and emission spectra. The receptor OMB shows rapid detection with lowest LOD (0.62 nM for Hg2+ ions and 0.77 nM for Cd2+ ions) and LOQ (2.08 nM for Hg2+ ions and 2.57 nM for Cd2+ ions) values. In addition, the receptor OMB exhibits 1:1 binding stoichiometry towards Hg2+ and Cd2+ ions with binding constant values of 5.5 × 106 M-1 and 4.6 × 106 M-1. Moreover, the synthesized receptor OMB possess ability to detect these analytes (Hg2+ and Cd2+ ions) in realistic samples (food and water) which was recognized using photoluminescence spectroscopy technique. In addition, the receptor OMB is also utilized to detect both the analytes in live HeLa cells. Thus, the overall results indicate that the receptor OMB was more suitable to detect the toxic analytes (Hg2+ and Cd2+ ions) present in the environment.
Collapse
Affiliation(s)
| | - Mari Ramya
- Department of Chemistry, Periyar University, Salem, 636 011, Tamil Nadu, India
| | | | - Jebiti Haribabu
- Facultad de Medicina, Universidad de Atacama, Los Carreras 1579, 1532502, Copiapo, Chile
| | - Cesar Echeverria
- Facultad de Medicina, Universidad de Atacama, Los Carreras 1579, 1532502, Copiapo, Chile
| |
Collapse
|
9
|
Futalan CM, Choi AES, Soriano HGO, Cabacungan MKB, Millare JC. Modification Strategies of Kapok Fiber Composites and Its Application in the Adsorption of Heavy Metal Ions and Dyes from Aqueous Solutions: A Systematic Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19052703. [PMID: 35270400 PMCID: PMC8910290 DOI: 10.3390/ijerph19052703] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 12/27/2021] [Accepted: 01/13/2022] [Indexed: 11/16/2022]
Abstract
Kapok fiber (Ceiba pentandra) belongs to a group of natural fibers that are mainly composed of cellulose, lignin, pectin, and small traces of inorganic compounds. These fibers are lightweight with hollow tubular structure that is easy to process and abundant in nature. Currently, kapok fibers are used in industry as filling material for beddings, upholstery, soft toys, and nonwoven materials. However, kapok fiber has also a potential application in the adsorptive removal of heavy metal ions and dyes from aqueous systems. This study aims to provide a comprehensive review about the recent developments on kapok fiber composites including its chemical properties, wettability, and surface morphology. Effective and innovative kapok fiber composites are analyzed with the help of characterization tools such as scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, energy-dispersive X-ray spectroscopy, and Brunauer-Emmett-Teller analysis. Different pre-treatment methods such as alkali and acid pre-treatment, oxidation pre-treatment, and Fenton reaction are discussed. These techniques are applied to enhance the hydrophilicity and to generate rougher fiber surfaces. Moreover, surface modification and synthesis of kapok fiber-based composites and its environmental applications are examined. There are various methods in the fabrication of kapok fiber composites that include chemical modification and polymerization. These procedures allow the kapok fiber composites to have higher adsorption capacities for selective heavy metal and dye removal.
Collapse
Affiliation(s)
- Cybelle Morales Futalan
- Department of Community and Environmental Resource Planning, University of the Philippines, Los Baños 4031, Laguna, Philippines
- Correspondence: or
| | - Angelo Earvin S. Choi
- Department of Chemical Engineering, De La Salle University, Taft Avenue, Manila 2401, Metro Manila, Philippines;
| | - Hannah Georgia O. Soriano
- School of Chemical, Biological, and Materials Engineering and Sciences, Mapua University, 658 Muralla St, Intramuros, Manila 1002, Metro Manila, Philippines; (H.G.O.S.); (M.K.B.C.); (J.C.M.)
| | - Melbourne Klein B. Cabacungan
- School of Chemical, Biological, and Materials Engineering and Sciences, Mapua University, 658 Muralla St, Intramuros, Manila 1002, Metro Manila, Philippines; (H.G.O.S.); (M.K.B.C.); (J.C.M.)
| | - Jeremiah C. Millare
- School of Chemical, Biological, and Materials Engineering and Sciences, Mapua University, 658 Muralla St, Intramuros, Manila 1002, Metro Manila, Philippines; (H.G.O.S.); (M.K.B.C.); (J.C.M.)
| |
Collapse
|
10
|
Development of a DNAzyme-based colorimetric biosensor assay for dual detection of Cd 2+ and Hg 2. Anal Bioanal Chem 2021; 413:7081-7091. [PMID: 34585255 DOI: 10.1007/s00216-021-03677-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/15/2021] [Accepted: 09/17/2021] [Indexed: 10/20/2022]
Abstract
A colorimetric biosensor assay has been developed for Cd2+ and Hg2+ detection based on Cd2+-dependent DNAzyme cleavage and Hg2+-binding-induced conformational switching of the G-quadruplex fragment. Two types of multifunctional magnetic beads (Cd-MBs and Hg-MBs) were synthesized by immobilizing two functionalized DNA sequences on magnetic beads via avidin-biotin chemistry. For Cd2+ detection, Cd-MBs are used as recognition probes, which are modified with a single phosphorothioate ribonucleobase (rA) substrate (PS substrate) and a Cd2+-specific DNAzyme (Cdzyme). In the presence of Cd2+, the PS substrate is cleaved by Cdzyme, and single-stranded DNA is released as the signal transduction sequence. After molecular assembly with the other two oligonucleotides, duplex DNA is produced, and it can be recognized and cleaved by FokI endonuclease. Thus, a signal output component consisting of a G-quadruplex fragment is released, which catalyzes the oxidation of ABTS with the addition of hemin and H2O2, inducing a remarkably amplified colorimetric signal. To rule out false-positive results and reduce interference signals, Hg-MBs modified with poly-T fragments were used as Hg2+ accumulation probes during the course of Cd2+ detection. On the other hand, Hg-MBs can perform their second function in Hg2+ detection by changing the catalytic activity of the G-quadruplex/hemin DNAzyme. In the presence of Hg2+, the G-quadruplex structure in Hg-MBs is disrupted upon Hg2+ binding. In the absence of Hg2+, an intensified color change can be observed by the naked eye for the formation of intact G-quadruplex/hemin DNAzymes. The biosensor assay exhibits excellent selectivity and high sensitivity. The detection limits for Cd2+ and Hg2+ are 1.9 nM and 19.5 nM, respectively. Moreover, the constructed sensors were used to detect environmental water samples, and the results indicate that the detection system is reliable and could be further used in environmental monitoring. The design strategy reported in this study could broadly extend the application of metal ion-specific DNAzyme-based biosensors.
Collapse
|