1
|
Chen WH, Maheshwaran S, Park YK, Ong HC. Iron-based electrode material composites for electrochemical sensor application in the environment: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 953:176128. [PMID: 39255942 DOI: 10.1016/j.scitotenv.2024.176128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 08/30/2024] [Accepted: 09/06/2024] [Indexed: 09/12/2024]
Abstract
This review explores the expanding role of electrochemical sensors across diverse domains such as environmental monitoring, medical diagnostics, and food quality assurance. In recent years, iron-based electrocatalysts have emerged as promising candidates for enhancing sensor performance. Notable for their non-toxicity, abundance, catalytic activity, and cost-effectiveness, these materials offer significant advantages. However, further investigation is needed to fully understand how iron-based materials' physical, chemical, and electrical properties influence their catalytic performance in sensor applications. It explores the overview of electrochemical sensor technology, examines the impact of iron-based materials and their characteristics on catalytic activity, and investigates various iron-based materials, their advantages, functionalization, and modification techniques. Additionally, the review investigates the application of iron-based electrode material composites in electrochemical sensors for real sample detections. Ultimately, continued research and development in this area promise to unlock new avenues for using iron-based electrode materials in sensor applications.
Collapse
Affiliation(s)
- Wei-Hsin Chen
- Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan 701, Taiwan; Research Center for Smart Sustainable Circular Economy, Tunghai University, Taichung 407, Taiwan; Department of Mechanical Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan.
| | - Selvarasu Maheshwaran
- Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan 701, Taiwan.
| | - Young-Kwon Park
- School of Environmental Engineering, University of Seoul, Seoul, 02504, Republic of Korea
| | - Hwai Chyuan Ong
- Department of Engineering, School of Engineering and Technology, Sunway University, Jalan Universiti, Bandar Sunway, 47500 Petaling Jaya, Selangor, Malaysia
| |
Collapse
|
2
|
Rahman MM, Sarkar B, Rahman MT, Jin GJ, Uddin MJ, Bhuiyan NH, Shim JS. Development of a highly sensitive CNT-metal graphene hybrid nano-IDA electrochemical biosensor for the diagnosis of Alzheimer's disease. Biomater Sci 2024; 12:5203-5214. [PMID: 39240173 DOI: 10.1039/d4bm00654b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2024]
Abstract
The blood-based detection of Alzheimer's disease (AD) is becoming challenging since the blood-brain barrier (BBB) restricts the direct circulation of AD molecules in the blood, thereby precluding the detection of AD at an early-stage. Herein, we report the development of a novel CNT-metal-porous graphene hybrid (CNT-MGH) nano-interdigitated array (n-IDA) electrochemical 8-well biosensor for the successful early-stage diagnosis of AD from blood. Laser-induced graphene (LIG) technology has been used to fabricate the proposed CNT-MGH n-IDA 8-well sensor. Firstly, the electrochemical characterization (i.e., electrode gap, material composition, etc.) of the proposed sensor was demonstrated by measuring p-aminophenol (PAP) with a limit of detection (LOD) of 0.1 picomole. Subsequently, the CNT-MGH n-IDA 8-well sensor was then used to diagnose AD via novel blood biomarkers p-Tau 217 and p-Tau 181 using an electrochemical enzyme-linked immunosorbent assay (e-ELISA) enzyme by-product PAP. During e-ELISA, the alkaline phosphatase enzyme (IgG-AP) tagged to the detection antibody produced an electroactive ELISA by-product PAP by reacting with the enzyme-substrate 4-aminophenyl phosphate (PAPP). Finally, the CNT-MGH n-IDA 8-well sensor was then used to measure the current generated by the redox reaction via the e-ELISA by-product PAP. While quantified, the proposed CNT-MGH n-IDA 8-well sensor successfully detected p-Tau 217 and p-Tau 181 proteins in blood with LODs of 0.16 pg ml-1 and 0.08 pg ml-1, respectively.
Collapse
Affiliation(s)
- M Mahabubur Rahman
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwang-woon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea.
| | - Bappa Sarkar
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwang-woon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea.
| | - Md Tareq Rahman
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwang-woon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea.
| | - Gyeong J Jin
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwang-woon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea.
| | - M Jalal Uddin
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwang-woon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea.
- Nano Genesis Inc., 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea
| | - Nabil H Bhuiyan
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwang-woon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea.
| | - Joon S Shim
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwang-woon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea.
- Nano Genesis Inc., 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea
| |
Collapse
|
3
|
Liu Q, Huang Y, Wang S, Yang S, Jiang Z, Huang S. Monodispersed Au nanoparticles decorated MoS 2 nanosheets with enhanced peroxidase-like activity based electrochemical H 2O 2 sensing for anticancer drug evaluations. Anal Chim Acta 2024; 1320:342996. [PMID: 39142770 DOI: 10.1016/j.aca.2024.342996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2024] [Revised: 07/18/2024] [Accepted: 07/19/2024] [Indexed: 08/16/2024]
Abstract
BACKGROUND The unique size, physical and chemical properties, and ultra-high stability of nanozymes have attracted extensive attentions in sensing, but improvement of catalytic activity of the nanozymes is still an urgent issue. Given the ultra-high simulated enzyme activity of metal nanoparticles and the advantage of multi-enzyme catalysis, an Au-decorated MoS2 nanosheets (MoS2/Au NS) integrating the double peroxidase-like (POD) activity is developed. RESULTS By optimizing and adjusting the density of AuNPs, as well as its morphology and other parameters, a monodisperse and high-density distribution of AuNPs on MoS2 nanosheets was obtained, which can greatly improve the POD-like activity of MoS2/Au NS. Nafion solution was applied to assist the modification of MoS2/Au NS on the electrode surface so as to improved its stability. An electrochemical H2O2 detection platform was constructed by modifying MoS2/Au NS nanozyme on the SPCE using the conductive Nafion solution. And the negatively charged sulfonic acid group can eliminate negatively charged electroactive substances to improve the specificity. Then ascorbic acid was used to stimulate tumor cells to produce H2O2 as therapeutic model, an ultrasensitive chronocoulometry detection for H2O2 in cell lysate was established. The logarithmically of ΔQ and the logarithmically of H2O2 concentration showed a good linear relationship between 1 μM and 500 mM, with a LOD value of 0.3 μM. SIGNIFICANCE The developed H2O2 sensor has excellent stability, reproducibility (RSD = 2.3 %, n = 6) and selectivity, realized the quantitative detection of H2O2 in cell lysate. Compared with commercial fluorescence detection kits for H2O2 in cell lysate, it is worth mentioning that the electrochemical H2O2 sensor developed in this study is simpler and faster, with higher sensitivity and lower cost. This provides a potential substitute for disease diagnosis and treatment evaluation based on accurate detection of H2O2.
Collapse
Affiliation(s)
- Qiwen Liu
- NMPA Key Laboratory for Clinical Research and Evaluation of Drug for Thoracic Diseases, School of Pharmaceutical Sciences, Guangzhou Medical University, Guangzhou, 511436, China
| | - Yang Huang
- NMPA Key Laboratory for Clinical Research and Evaluation of Drug for Thoracic Diseases, School of Pharmaceutical Sciences, Guangzhou Medical University, Guangzhou, 511436, China
| | - Sheng Wang
- NMPA Key Laboratory for Clinical Research and Evaluation of Drug for Thoracic Diseases, School of Pharmaceutical Sciences, Guangzhou Medical University, Guangzhou, 511436, China
| | - Shuo Yang
- NMPA Key Laboratory for Clinical Research and Evaluation of Drug for Thoracic Diseases, School of Pharmaceutical Sciences, Guangzhou Medical University, Guangzhou, 511436, China
| | - Zhengjin Jiang
- Institute of Pharmaceutical Analysis, College of Pharmacy, Guangdong Province Key Laboratory of Pharmacodynamic Constituents of TCM and New Drugs Research, International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Ministry of Education (MOE) of China, Jinan University, Guangzhou, 510632, China.
| | - Shengfeng Huang
- NMPA Key Laboratory for Clinical Research and Evaluation of Drug for Thoracic Diseases, School of Pharmaceutical Sciences, Guangzhou Medical University, Guangzhou, 511436, China.
| |
Collapse
|
4
|
Zhang Y, Yang Z, Qiao C, Liu Y, Wang C, Zeng X, Hou J, Huo D, Hou C. Synergistic enhancement of wearable biosensor through Pt single-atom catalyst for sweat analysis. Biosens Bioelectron 2024; 258:116354. [PMID: 38723331 DOI: 10.1016/j.bios.2024.116354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 04/02/2024] [Accepted: 04/30/2024] [Indexed: 05/21/2024]
Abstract
Real-time monitoring of biological markers in sweat is a valuable tool for health assessment. In this study, we have developed an innovative wearable biosensor for precise analysis of glucose in sweat during physical activities. The sensor is based on a single-atom catalyst of platinum (Pt) uniformly dispersed on tricobalt tetroxide (Co3O4) nanorods and reduced graphene oxide (rGO), featuring a unique three-dimensional nanostructure and excellent glucose electrocatalytic performance with a wide detection range of 1-800 μM. Additionally, density functional theory calculations have revealed the synergetic role of Pt active sites in the Pt single-atom catalyst (Co3O4/rGO/Pt) in glucose adsorption and electron transfer, thereby enhancing sensor performance. To enable application in wearable devices, we designed an S-shaped microfluidic chip and a point-of-care testing (POCT) device, both of which were validated for effectiveness through actual use by volunteers. This research provides valuable insights and innovative approaches for analyzing sweat glucose using wearable devices, contributing to the advancement of personalized healthcare.
Collapse
Affiliation(s)
- Yong Zhang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Zhihao Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Cailin Qiao
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Yiyi Liu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Cuncun Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Xin Zeng
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Jingzhou Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China; Chongqing Engineering and Technology Research Center of Intelligent Rehabilitation and Eldercare, Chongqing City Management College, Chongqing, 401331, PR China.
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China; Chongqing Engineering and Technology Research Center of Intelligent Rehabilitation and Eldercare, Chongqing City Management College, Chongqing, 401331, PR China.
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China; Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, 400044, PR China.
| |
Collapse
|
5
|
Lu C, Tang Z, Wang D, Chen L, Zhao J. Advances in polyoxometalate-based electrochemical sensors in the last three years. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:5133-5145. [PMID: 39007918 DOI: 10.1039/d4ay01090f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/16/2024]
Abstract
As a famous subclass of metal-oxide cluster materials, polyoxometalates (POMs) feature variable architectures, reversible multi-electron transport capability, catalytic activity, and redox capacity. These attributes endow POMs with great potential as promising electrode materials in electrochemical sensors (ECSs). Up to now, POM-based ECSs have been passionately studied, and diverse POM-based redox ECSs, aptasensors and immunosensors have emerged. And these POM-based ECSs generally demonstrate fast response, low detection limit, strong selectivity and high antijamming capability. This review mainly focuses on the remarkable advancement of POM-based ECSs in environmental monitoring, food safety and biomedicine from 2021, aiming to furnish theoretical insights that inform the design and development of innovative sensors.
Collapse
Affiliation(s)
- Changyuan Lu
- School of Environmental Engineering, Yellow River Conservancy Technical Institute, Kaifeng 475004, China
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| | - Zhigang Tang
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| | - Dan Wang
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| | - Lijuan Chen
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| | - Junwei Zhao
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, China.
| |
Collapse
|
6
|
Solanki R, Patra I, Kumar TCA, Kumar NB, Kandeel M, Sivaraman R, Turki Jalil A, Yasin G, Sharma S, Abdulameer Marhoon H. Smartphone-Based Techniques Using Carbon Dot Nanomaterials for Food Safety Analysis. Crit Rev Anal Chem 2024; 54:923-941. [PMID: 35857650 DOI: 10.1080/10408347.2022.2099733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
The development of portable and efficient nanoprobes to realize the quantitative/qualitative onsite determination of food pollutants is of immense importance for safeguarding human health and food safety. With the advent of the smartphone, the digital imaging property causes it to be an ideal diagnostic substrate to point-of-care analysis probes. Besides, merging the versatility of carbon dots nanostructures and bioreceptor abilities has opened an innovative assortment of construction blocks to design advanced nanoprobes or improving those existing ones. On this ground, massive endeavors have been made to combine mobile phones with smart nanomaterials to produce portable (bio)sensors in a reliable, low cost, rapid, and even facile-to-implement area with inadequate resources. Herein, this work outlines the latest advancement of carbon dots nanostructures on smartphone for onsite detecting of agri-food pollutants. Particularly, we afford a summary of numerous approaches applied for target molecule diagnosis (pesticides, mycotoxins, pathogens, antibiotics, and metal ions), for instance microscopic imaging, fluorescence, colorimetric, and electrochemical techniques. Authors tried to list those scaffolds that are well-recognized in complex media or those using novel constructions/techniques. Lastly, we also point out some challenges and appealing prospects related to the enhancement of high-efficiency smartphone based carbon dots systems.
Collapse
Affiliation(s)
- Reena Solanki
- Department of Chemistry, Dr APJ Abdul Kalam University, Indore, India
| | | | - T Ch Anil Kumar
- Department of Mechanical Engineering, Vignan's Foundation for Science Technology and Research, Vadlamudi, India
| | - N Bharath Kumar
- Department of Electrical and Electronics Engineering, Vignan's Foundation for Science Technology and Research, Guntur, India
| | - Mahmoud Kandeel
- Department of Biomedical Sciences, College of Veterinary Medicine, King Faisal University, Al-Ahsa, Saudi Arabia
| | - R Sivaraman
- Department of Mathematics, Dwaraka Doss Goverdhan Doss Vaishnav College, University of Madras, Arumbakkam, Chennai, India
| | - Abduladheem Turki Jalil
- Medical Laboratories Techniques Department, Al-Mustaqbal University College, Babylon, Hilla, Iraq
| | - Ghulam Yasin
- Department of Botany, university of Bahauddin Zakariya, Multan, Pakistan
| | - Sandhir Sharma
- Chitkara Business School, Chitkara University, Punjab, India
| | - Haydar Abdulameer Marhoon
- Information and Communication Technology Research Group, Scientific Research Center, Al-Ayen University, Iraq
| |
Collapse
|
7
|
Sun E, Gu Z, Li H, Liu X, Li Y, Xiao F. Flexible Graphene Paper Modified Using Pt&Pd Alloy Nanoparticles Decorated Nanoporous Gold Support for the Electrochemical Sensing of Small Molecular Biomarkers. BIOSENSORS 2024; 14:172. [PMID: 38667165 PMCID: PMC11048118 DOI: 10.3390/bios14040172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/27/2024] [Accepted: 03/29/2024] [Indexed: 04/28/2024]
Abstract
The exploration into nanomaterial-based nonenzymatic biosensors with superb performance in terms of good sensitivity and anti-interference ability in disease marker monitoring has always attained undoubted priority in sensing systems. In this work, we report the design and synthesis of a highly active nanocatalyst, i.e., palladium and platinum nanoparticles (Pt&Pd-NPs) decorated ultrathin nanoporous gold (NPG) film, which is modified on a homemade graphene paper (GP) to develop a high-performance freestanding and flexible nanohybrid electrode. Owing to the structural characteristics the robust GP electrode substrate, and high electrochemically catalytic activities and durability of the permeable NPG support and ultrafine and high-density Pt&Pd-NPs on it, the resultant Pt&Pd-NPs-NPG/GP electrode exhibits excellent sensing performance of low detection limitation, high sensitivity and anti-interference capability, good reproducibility and long-term stability for the detection of small molecular biomarkers hydrogen peroxide (H2O2) and glucose (Glu), and has been applied to the monitoring of H2O2 in different types of live cells and Glu in body fluids such as urine and fingertip blood, which is of great significance for the clinical diagnosis and prognosis in point-of-care testing.
Collapse
Affiliation(s)
- Encheng Sun
- Technology Inspection Center of Shengli Oilfield Branch, Sinopec (Shandong) Testing and Evaluation Research Co. Ltd., China Petrochemical Corporation, Dongying 257000, China; (E.S.); (H.L.); (X.L.); (Y.L.)
- Sinopec (Shandong) Testing and Evaluation Research Co. Ltd., China Petrochemical Corporation, Dongying 257000, China
| | - Zhenqi Gu
- Technology Inspection Center of Shengli Oilfield Branch, Sinopec (Shandong) Testing and Evaluation Research Co. Ltd., China Petrochemical Corporation, Dongying 257000, China; (E.S.); (H.L.); (X.L.); (Y.L.)
| | - Haoran Li
- Technology Inspection Center of Shengli Oilfield Branch, Sinopec (Shandong) Testing and Evaluation Research Co. Ltd., China Petrochemical Corporation, Dongying 257000, China; (E.S.); (H.L.); (X.L.); (Y.L.)
| | - Xiao Liu
- Technology Inspection Center of Shengli Oilfield Branch, Sinopec (Shandong) Testing and Evaluation Research Co. Ltd., China Petrochemical Corporation, Dongying 257000, China; (E.S.); (H.L.); (X.L.); (Y.L.)
| | - Yuan Li
- Technology Inspection Center of Shengli Oilfield Branch, Sinopec (Shandong) Testing and Evaluation Research Co. Ltd., China Petrochemical Corporation, Dongying 257000, China; (E.S.); (H.L.); (X.L.); (Y.L.)
| | - Fei Xiao
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
| |
Collapse
|
8
|
Hu C, Wang L, Liu S, Sheng X, Yin L. Recent Development of Implantable Chemical Sensors Utilizing Flexible and Biodegradable Materials for Biomedical Applications. ACS NANO 2024; 18:3969-3995. [PMID: 38271679 DOI: 10.1021/acsnano.3c11832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
Implantable chemical sensors built with flexible and biodegradable materials exhibit immense potential for seamless integration with biological systems by matching the mechanical properties of soft tissues and eliminating device retraction procedures. Compared with conventional hospital-based blood tests, implantable chemical sensors have the capability to achieve real-time monitoring with high accuracy of important biomarkers such as metabolites, neurotransmitters, and proteins, offering valuable insights for clinical applications. These innovative sensors could provide essential information for preventive diagnosis and effective intervention. To date, despite extensive research on flexible and bioresorbable materials for implantable electronics, the development of chemical sensors has faced several challenges related to materials and device design, resulting in only a limited number of successful accomplishments. This review highlights recent advancements in implantable chemical sensors based on flexible and biodegradable materials, encompassing their sensing strategies, materials strategies, and geometric configurations. The following discussions focus on demonstrated detection of various objects including ions, small molecules, and a few examples of macromolecules using flexible and/or bioresorbable implantable chemical sensors. Finally, we will present current challenges and explore potential future directions.
Collapse
Affiliation(s)
- Chen Hu
- School of Materials Science and Engineering, The Key Laboratory of Advanced Materials of Ministry of Education, State Key Laboratory of New Ceramics and Fine Processing, Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing 100084, P. R. China
| | - Liu Wang
- Key Laboratory of Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, P. R. China
| | - Shangbin Liu
- School of Materials Science and Engineering, The Key Laboratory of Advanced Materials of Ministry of Education, State Key Laboratory of New Ceramics and Fine Processing, Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing 100084, P. R. China
| | - Xing Sheng
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology, Institute for Precision Medicine, Laboratory of Flexible Electronics Technology, IDG/McGovern Institute for Brain Research, Tsinghua University, Beijing 100084, P. R. China
| | - Lan Yin
- School of Materials Science and Engineering, The Key Laboratory of Advanced Materials of Ministry of Education, State Key Laboratory of New Ceramics and Fine Processing, Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing 100084, P. R. China
| |
Collapse
|
9
|
Zhou J, Zhou S, Fan P, Li X, Ying Y, Ping J, Pan Y. Implantable Electrochemical Microsensors for In Vivo Monitoring of Animal Physiological Information. NANO-MICRO LETTERS 2023; 16:49. [PMID: 38087121 PMCID: PMC10716106 DOI: 10.1007/s40820-023-01274-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 10/24/2023] [Indexed: 10/11/2024]
Abstract
In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases. Currently, implantable electrochemical microsensors have emerged as a prominent area of research. These microsensors not only fulfill the technical requirements for monitoring animal physiological information but also offer an ideal platform for integration. They have been extensively studied for their ability to monitor animal physiological information in a minimally invasive manner, characterized by their bloodless, painless features, and exceptional performance. The development of implantable electrochemical microsensors for in vivo monitoring of animal physiological information has witnessed significant scientific and technological advancements through dedicated efforts. This review commenced with a comprehensive discussion of the construction of microsensors, including the materials utilized and the methods employed for fabrication. Following this, we proceeded to explore the various implantation technologies employed for electrochemical microsensors. In addition, a comprehensive overview was provided of the various applications of implantable electrochemical microsensors, specifically in the monitoring of diseases and the investigation of disease mechanisms. Lastly, a concise conclusion was conducted on the recent advancements and significant obstacles pertaining to the practical implementation of implantable electrochemical microsensors.
Collapse
Affiliation(s)
- Jin Zhou
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
| | - Shenghan Zhou
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
| | - Peidi Fan
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
| | - Xunjia Li
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, People's Republic of China
| | - Yibin Ying
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, People's Republic of China
| | - Jianfeng Ping
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China.
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, People's Republic of China.
| | - Yuxiang Pan
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China.
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, People's Republic of China.
| |
Collapse
|
10
|
Zhao Y, Jin KQ, Li JD, Sheng KK, Huang WH, Liu YL. Flexible and Stretchable Electrochemical Sensors for Biological Monitoring. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023:e2305917. [PMID: 37639636 DOI: 10.1002/adma.202305917] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 08/23/2023] [Indexed: 08/31/2023]
Abstract
The rise of flexible and stretchable electronics has revolutionized biosensor techniques for probing biological systems. Particularly, flexible and stretchable electrochemical sensors (FSECSs) enable the in situ quantification of numerous biochemical molecules in different biological entities owing to their exceptional sensitivity, fast response, and easy miniaturization. Over the past decade, the fabrication and application of FSECSs have significantly progressed. This review highlights key developments in electrode fabrication and FSECSs functionalization. It delves into the electrochemical sensing of various biomarkers, including metabolites, electrolytes, signaling molecules, and neurotransmitters from biological systems, encompassing the outer epidermis, tissues/organs in vitro and in vivo, and living cells. Finally, considering electrode preparation and biological applications, current challenges and future opportunities for FSECSs are discussed.
Collapse
Affiliation(s)
- Yi Zhao
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Kai-Qi Jin
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Jing-Du Li
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Kai-Kai Sheng
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Wei-Hua Huang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Yan-Ling Liu
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| |
Collapse
|
11
|
Flexible electrochemical sensor with Fe/Co bimetallic oxides for sensitive analysis of glucose in human tears. Anal Chim Acta 2023; 1243:340781. [PMID: 36697172 DOI: 10.1016/j.aca.2023.340781] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 12/09/2022] [Accepted: 01/01/2023] [Indexed: 01/09/2023]
Abstract
The construction of uniformly dispersed structure with abundant active sites is crucial for fast electron transport and advancing electrocatalytic reactions. Herein, FexCoyO4-rGO was prepared by depositing Fe and Co bimetallic oxides in-situ on reduced graphene oxide through a simple process combined hydrothermal reaction and calcination. Fe was elaborately introduced into the synthesis of metal oxides to alleviate the aggregation of cobalt oxides and obtain nanocomposites with homogeneously structured and abundant redox sites, and the bimetallic oxides nanomaterials had enhanced electrocatalysis under the synergistic effect. The flexible electrode prepared from FexCoyO4-rGO exhibited excellent detection performance for glucose with a detection limit down low to 0.07 μM and a sensitivity of 1510 μM cm-2 mA-1. The adoption of flexible substrates improved the wearability of the electrode and broadened its practicality for detecting biomarkers on the skin surface. The constructed sensor was successfully used in the dynamic analysis of glucose content in tears, and the results were highly consistent with the test outcome of a commercial test kit, demonstrating its application prospects in non-invasive epidermal diabetes mellitus diagnosis.
Collapse
|
12
|
High-performance enzyme-free glucose and hydrogen peroxide sensors based on bimetallic AuCu nanoparticles coupled with multi-walled carbon nanotubes. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
13
|
Cetinkaya A, Kaya SI, Şenel P, Cini N, Atici EB, Ozkan SA, Yurtsever M, Gölcü A. Detection of Axitinib Using Multiwalled Carbon Nanotube-Fe 2O 3/Chitosan Nanocomposite-Based Electrochemical Sensor and Modeling with Density Functional Theory. ACS OMEGA 2022; 7:34495-34505. [PMID: 36188240 PMCID: PMC9520732 DOI: 10.1021/acsomega.2c04244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 09/06/2022] [Indexed: 06/16/2023]
Abstract
In this study, axitinib (AXI), a potent and selective inhibitor of vascular endothelial growth factor receptor (VEGFR) tyrosine kinase and used as a second-generation targeted drug, was investigated electrochemically under optimized conditions using multiwalled carbon nanotubes/iron(III) oxide nanoparticle-chitosan nanocomposite (MWCNT/Fe2O3@chitosan NC) modified on the glassy carbon electrode (GCE) surface. Characterization of the modified electrode was performed using scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The adsorptive stripping differential pulse voltammetric (AdSDPV) technique was used for the sensitive, rapid, and precise detection of AXI. The current peak obtained with the MWCNT/Fe2O3@chitosan NC modified electrode was 23 times higher compared to the bare electrode. The developed modified electrode showed excellent electrocatalytic activity in AXI oxidation. Under optimized conditions, the effect of supporting electrolyte and pH was investigated, and 0.1 M H2SO4 was chosen as the electrolyte with the highest peak current for the target analyte. In the concentration range of MWCNT/Fe2O3@chitosan NC/GCE, 6 × 10-9 and 1 × 10-6 M, the limit of detection (LOD) and limit of quantification (LOQ) values were calculated to be 0.904 and 0.0301 pM, respectively. Tablet and serum samples were used for the applicability of the developed sensor, relative standard deviation (RSD) values for all samples were below 2%, and the recovery results were 99.23 and 101.84%, respectively. The MWCNT/Fe2O3@chitosan NC/GCE designed to determine AXI demonstrated the applicability, selectivity, precision, and accuracy of the sensor. The mechanism of electron transfer from the modified GCE surface to the analyte solution is studied via modeling the modified GCE surface by the density functional theory (DFT) method at B3LYP/6-311+g(d,p) and M062X/6-31g(d,p) levels. We observed that the iron oxide nanoparticles play an important role in channeling electron flow from the analyte solution to the MWCNT-coated GCE electrode surface. Adsorption of the nanocomposite material onto the GCE surface occurs via strong electrostatic interactions, including ionic and hydrogen bond formations. During the adsorption-controlled oxidation process of the axitinib, the electrons are transferred via the highest occupied molecular orbital (HOMO) localized on the iron oxide moiety to the lowest unoccupied molecular orbital (LUMO) of the MWCNT/GCE surface.
Collapse
Affiliation(s)
- Ahmet Cetinkaya
- Department
of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Turkiye
| | - S. Irem Kaya
- Department
of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Turkiye
- Department
of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, 06010 Ankara, Turkiye
| | - Pelin Şenel
- Chemistry
Department, Science and Letters Faculty, Istanbul Technical University, Maslak, 34469 Istanbul, Turkiye
| | - Nejla Cini
- Chemistry
Department, Science and Letters Faculty, Istanbul Technical University, Maslak, 34469 Istanbul, Turkiye
| | - Esen B. Atici
- Research
& Development Center, DEVA Holding A.S., 59520 Tekirdağ, Turkiye
| | - Sibel A. Ozkan
- Department
of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Turkiye
| | - Mine Yurtsever
- Chemistry
Department, Science and Letters Faculty, Istanbul Technical University, Maslak, 34469 Istanbul, Turkiye
| | - Ayşegül Gölcü
- Chemistry
Department, Science and Letters Faculty, Istanbul Technical University, Maslak, 34469 Istanbul, Turkiye
| |
Collapse
|