1
|
Farahmandzadeh F, Kermanshahian K, Molahosseini E, Molaei M, Karimipour M. Highly fluorescent CdTe/ZnSe quantum dot-based "turn-off" sensor for the on-site rapid detection of Lead ions in aqueous medium. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 324:124914. [PMID: 39137711 DOI: 10.1016/j.saa.2024.124914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 07/21/2024] [Accepted: 07/29/2024] [Indexed: 08/15/2024]
Abstract
Lead (Pb) is a heavy metal known for its adverse effects on both human health and the environment. In recent years, the industrial utilization of Pb2+ has surged, underscoring the imperative need for efficient measurement methods. In this study, a rapid and simple photochemical method was used to synthesize thioglycolic acid (TGA)-stabilized CdTe/ZnSe core-shell quantum dots (QDs). These CdTe/ZnSe QDs emit vibrant green fluorescence and exhibit remarkable quenching in the presence of Pb2+ ions. This property enables the development of an on-site on/off sensor without the necessity of additional modifications. The proposed sensor possesses an outstanding sensitivity to Pb2+, with a detection limit and linear range of 31.8 nM and 50 nM-10 µM, respectively. Importantly, the selectivity of this fluorescence-based sensor was validated by analyzing various positively and negatively charged ions. Furthermore, the developed sensor showed reliable performance against real river, agricultural, and tap water, as confirmed by Inductively Coupled Plasma (ICP) analysis. Additionally, CdTe/ZnSe QDs immobilized on glass slides were successfully employed for on-site water sample analysis, providing a versatile solution for environmental monitoring.
Collapse
Affiliation(s)
- Farzad Farahmandzadeh
- Department of Physics, Faculty of Science, Vali-e-Asr University of Rafsanjan, Rafsanjan, Iran
| | - Kimia Kermanshahian
- Laboratory of Bioanalysis, Institute of Biochemistry & Biophysics, University of Tehran, Tehran, Iran
| | | | - Mehdi Molaei
- Department of Physics, Faculty of Science, Vali-e-Asr University of Rafsanjan, Rafsanjan, Iran.
| | - Masoud Karimipour
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and the Barcelona Institute of Science and Technology (BIST), Barcelona, Spain
| |
Collapse
|
2
|
Hassibian S, Esmaelpourfarkhani M, Abnous K, Amin M, Ghazvinian F, Alibolandi M, Ramezani M, Nameghi MA, Mollasalehi H, Farrokhi N, Dehnavi SM, Taghdisi SM. A turn-on fluorescent aptasensor for Pb 2+ detection based on rhodamine B dye leakage from the internal cavity of hollow gold nanoparticles. Food Chem 2024; 463:141440. [PMID: 39348770 DOI: 10.1016/j.foodchem.2024.141440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Revised: 09/21/2024] [Accepted: 09/24/2024] [Indexed: 10/02/2024]
Abstract
In this project, a sensitive fluorescent aptasensor was fabricated to detect lead ions (Pb2+) by applying hollow gold nanoparticles (HGNPs) as a nano-carrier and rhodamine B (RDB) fluorescent dye as the signal agent. In the aptasensor that was created, the specific attachment of the aptamers to Pb2+ ions led to the release of aptamer from the chitosan (CTS) coated-HGNPs loaded with RDB, causing an increase in fluorescence intensity due to the leakage of RDB. The method demonstrated specific detection of the target analyte, achieving a detection limit (LOD) of 1 ppb and a broad linear dynamic range spanning from 2 to 1000 ppb. The aptasensor was able to accurately measure the concentration of Pb2+ in human serum, low-fat milk, and mineral water samples. The suggested biosensor, which offers the benefits of simplicity, user-friendliness, affordability, and high sensitivity, is well-suited for use with complex samples such as environmental and clinical samples.
Collapse
Affiliation(s)
- Sepideh Hassibian
- Department of Cell and Molecular Biology, Faculty of Life Science and Biotechnology, Shahid Beheshti University, Tehran, Iran
| | - Masoomeh Esmaelpourfarkhani
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Khalil Abnous
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mahsa Amin
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Fatemeh Ghazvinian
- Department of Cell and Molecular Biology, Faculty of Life Science and Biotechnology, Shahid Beheshti University, Tehran, Iran
| | - Mona Alibolandi
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Ramezani
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Morteza Alinezhad Nameghi
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hamidreza Mollasalehi
- Department of Microbiology and Microbial Biotechnology, Faculty of Life Science and Biotechnology, Shahid Beheshti University, Tehran, Iran
| | - Naser Farrokhi
- Department of Cell and Molecular Biology, Faculty of Life Science and Biotechnology, Shahid Beheshti University, Tehran, Iran
| | - Seyed Mohsen Dehnavi
- Department of Cell and Molecular Biology, Faculty of Life Science and Biotechnology, Shahid Beheshti University, Tehran, Iran.
| | - Seyed Mohammad Taghdisi
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
3
|
Zhang J, Suo Z, Liang R, Wei M, Ren W, Xu Y, He B, Jin H, Zhao R. Label-free ratiometric fluorescence detection of Pb 2+via structure-specific fluorescent dyes and dual signal amplification. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:6229-6240. [PMID: 39206535 DOI: 10.1039/d4ay01369g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
Lead ions (Pb2+) are a widely distributed and highly toxic heavy metal pollutant, which seriously threatens the environment, economy and human safety. Here, a label-free ratiometric fluorescent biosensor was constructed for Pb2+ detection using DNAzyme-driven target cycling and exonuclease III (Exo III)-mediated DNA cycling as a dual signal amplification strategy. The SYBR Green I (SGI) and N-methyl mesoporphyrin IX (NMM) used in this study are characterized by low cost, storage resistance, and short preparation time compared with conventional signaling probes labeled with fluorescent groups. Unlike the single-emission fluorescence strategy, monitoring the fluorescence intensity ratio of SGI and NMM can effectively reduce external interference to achieve accurate detection of Pb2+. DNAzyme structures on the surface of magnetic beads (MBs) can recognize Pb2+ and activate the target circulatory system to cleave single-stranded DNA (ssDNA). The ssDNA further initiated the Exo III-assisted DNA circulatory system to digest double-stranded DNA (dsDNA) and release guanine-rich G1. Finally, the fluorescence signals of SGI and NMM were weakened and enhanced, respectively. The sensing strategy achieved a wide linear range from 0.5 to 500 nM and a low limit of detection (LOD) of 26.4 pM. Furthermore, its anti-interference ability and potential applicability for Pb2+ detection in actual samples were verified. This work ingeniously combines the dual signal amplification strategy with the ratiometric sensing strategy constructed by structure-specific fluorescent dyes, which provides a promising method for constructing sensitive and accurate fluorescent biosensors.
Collapse
Affiliation(s)
- Jinmin Zhang
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| | - Zhiguang Suo
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| | - Ruirui Liang
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| | - Min Wei
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| | - Wenjie Ren
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| | - Yiwei Xu
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| | - Baoshan He
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| | - Huali Jin
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| | - Renyong Zhao
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| |
Collapse
|
4
|
Esmaelpourfarkhani M, Yaghmaei M, Ramezani M, Alibolandi M, Abnous K, Taghdisi SM. Perylene Diimide-based Fluorescent Aptasensor for Quantitative Analysis of Pb2+ Based on Terminal Deoxynucleotidyl Transferase-assisted Formation of Elongated Aptamer and Gold Nanoparticles. J Fluoresc 2024:10.1007/s10895-024-03923-2. [PMID: 39269551 DOI: 10.1007/s10895-024-03923-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2024] [Accepted: 09/04/2024] [Indexed: 09/15/2024]
Abstract
Due to the exceedingly poisonous properties of Pb2+, it is imperative to conduct a thorough assessment of its quantity in both biological and environmental samples, as this is crucial for safeguarding public health. This study describes an economic turn-off fluorescent aptasensor for the quantitative analysis of Pb2+ employing 3,4,9,10-perylenetetracarboxylic acid diimide (PTCDI) as a cost-effective fluorophore, gold nanoparticles (AuNPs) as separating agent and an elongated aptamer as both targeting agent and PTCDI loading site. The fundamental principle of the suggested fluorescent aptasensor, which is based on PTCDI, relies on detecting variations in the fluorescence intensity of PTCDI when an elongated aptamer (as single-stranded DNA) is present or absent. The advanced aptasensor is advantageous due to the elongation of the lead aptamer sequence length induced by terminal deoxynucleotidyl transferase (TdT), resulting in enhanced sensitivity. The presence of Pb2+ and the centrifugation process causes the separation of the poly A-modified aptamer/Pb2+ conjugate from the poly T sequence. Hence, the interaction of PTCDI with the poly A moiety in the modified aptamer leads to a decrease in its fluorescence emission. The findings showcased that the fluorescent aptasensor exhibited exceptional specificity towards Pb2+ ions, while the biosensing platform accomplished an impressive detection limit of 3.7 pM. Moreover, the suggested aptasensor utilizing PTCDI exhibits a commendable capability in quantitatively analyzing Pb2+ within human serum samples and mineral water.
Collapse
Affiliation(s)
- Masoomeh Esmaelpourfarkhani
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mahdi Yaghmaei
- School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Ramezani
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mona Alibolandi
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Khalil Abnous
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
- Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Seyed Mohammad Taghdisi
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
- Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
5
|
Liu Y, Xu J, Wu Z, Cai Y, Zhao Z, Qiu J. Development of a fluorescent DNA sensor for dual detection of heavy metal ions utilising DAPI in distinct buffers. Food Chem 2024; 451:139390. [PMID: 38653103 DOI: 10.1016/j.foodchem.2024.139390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 04/12/2024] [Accepted: 04/14/2024] [Indexed: 04/25/2024]
Abstract
The DNA-based biosensor utilises a thymine/guanine(T/G)-rich ODN-4 scaffold with 4',6-diamidino-2-phenylindole(DAPI) as a fluorescent emissary to monitor mercury/lead(Hg(II)/Pb(II)) ions simultaneously. Key to its bifocal detection capability is the twin unbound cytosine(C) bases strategically bridging the G-quadruplex and T-rich sequences, enabling their synergistic interplay. It facilitates the recognition of Hg(II)/Pb(II) ions, characterised by high specificity, and effectively mitigates interference from silver(Ag(I)). The G-quadruplex, guided by the C bases, induces a conformational transition in T-Hg(II)-T complexes, resulting in intense fluorescence. Pb(II) causes a spatial shift in the G-quadruplex, relaxing the T-Hg(II)-T base pairs and attenuating the fluorescence signal. The ODN-4 exhibits a robust, linear correlation with Hg(II) concentration (4.09 nmol/L to 1000 nmol/L) and Pb(II) concentration (3.22 nmol/L to 5 μmol/L). Recovery rates in milk, tap water, and rice water specimens with both ions validate method accuracy (Hg(II): 95.19% to 104.68%, Pb(II): 98.20% to 103.46%). It holds promising prospects for practical food analysis.
Collapse
Affiliation(s)
- Yuxin Liu
- Zhejiang Key Laboratory of Silkworm Bioreactor and Biomedicine, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Jiaxuan Xu
- Zhejiang Key Laboratory of Silkworm Bioreactor and Biomedicine, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Ziyi Wu
- Zhejiang Key Laboratory of Silkworm Bioreactor and Biomedicine, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Yule Cai
- Zhejiang Key Laboratory of Silkworm Bioreactor and Biomedicine, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Zihan Zhao
- Zhejiang Key Laboratory of Silkworm Bioreactor and Biomedicine, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Jieqiong Qiu
- Zhejiang Key Laboratory of Silkworm Bioreactor and Biomedicine, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, China.
| |
Collapse
|
6
|
Rouhi N, Khoshbin Z, Rezaei M, Abnous K, Taghdisi SM. A sensitive aptasensor mediated by gold nanoparticles/metal organic framework lattice for detection of Pb 2+ ion in marine products. Anal Chim Acta 2024; 1317:342893. [PMID: 39030001 DOI: 10.1016/j.aca.2024.342893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 06/15/2024] [Accepted: 06/18/2024] [Indexed: 07/21/2024]
Abstract
Herein, an enzyme-free fluorescent aptasensor was introduced for the ultrasensitive quantification of lead (Pb2+) ion as a hazardous pollutant of the environment and foodstuffs. A nanocomposite of zeolitic imidazolate frameworks-8 and gold nanoparticles (ZIF-8@AuNPs) was utilized as an efficient quencher of the fluorescence intensity of carboxyfluorescein (FAM) signal reporter. The establishment of a hybrid structure between attached aptamer on ZIF-8@AuNPs nanocomposite, and its FAM-tagged complementary (CP) strand decreased the fluorescence response. The preferential binding between the aptamer and Pb2+ released CP strands, which retrieved the fluorescence signal. The aptasensor could assess Pb2+ in the linear concentration range of 1 pM-1 nM with a detection limit (LOD) of 0.24 pM. Besides, it could quantify Pb2+ in various samples, including fish, shrimp, tap water, milk, and serum samples. The developed aptasensor with the superiorities of easiness, cost-effectiveness, easy-to-operate, and rapidness is promising for controlling marine foodstuff safety.
Collapse
Affiliation(s)
- Nadiyeh Rouhi
- Seafood Processing Department, Marine Science Faculty, Tarbiat Modares University, Tehran, Iran
| | - Zahra Khoshbin
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Masoud Rezaei
- Department of Sea Food Processing, Faculty of Marine Sciences, Tarbiat Modares University, P.O. Box 46414-356, Noor, Iran
| | - Khalil Abnous
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Seyed Mohammad Taghdisi
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
7
|
Qin M, Khan IM, Ding N, Qi S, Dong X, Zhang Y, Wang Z. Aptamer-modified paper-based analytical devices for the detection of food hazards: Emerging applications and future perspective. Biotechnol Adv 2024; 73:108368. [PMID: 38692442 DOI: 10.1016/j.biotechadv.2024.108368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 03/10/2024] [Accepted: 04/24/2024] [Indexed: 05/03/2024]
Abstract
Food analysis plays a critical role in assessing human health risks and monitoring food quality and safety. Currently, there is a pressing need for a reliable, portable, and quick recognition element for point-of-care testing (POCT) to better serve the demands of on-site food analysis. Aptamer-modified paper-based analytical devices (Apt-PADs) have excellent characteristics of high portability, high sensitivity, high specificity, and on-site detection, which have been widely used and concerned in the field of food safety. The article reviews the basic components and working principles of Apt-PADs, and introduces their representative applications detecting food hazards. Finally, the advantages, challenges, and future directions of Apt-PADs-based sensing performance are discussed, to provide new directions and insights for researchers to select appropriate Apt-PADs according to specific applications.
Collapse
Affiliation(s)
- Mingwei Qin
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Imran Mahmood Khan
- Nottingham Ningbo China Beacons of Excellence Research and Innovation Institute, University of Nottingham Ningbo China, Ningbo 315100, PR China
| | - Ning Ding
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Shuo Qi
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Xiaoze Dong
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Yin Zhang
- Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu 610106, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China; Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu 610106, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China; National Engineering Research Center for Functional Food, Jiangnan University, Wuxi 214122, China.
| |
Collapse
|
8
|
Kumar S, Kaushal JB, Lee HP. Sustainable Sensing with Paper Microfluidics: Applications in Health, Environment, and Food Safety. BIOSENSORS 2024; 14:300. [PMID: 38920604 PMCID: PMC11202065 DOI: 10.3390/bios14060300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 06/04/2024] [Accepted: 06/05/2024] [Indexed: 06/27/2024]
Abstract
This manuscript offers a concise overview of paper microfluidics, emphasizing its sustainable sensing applications in healthcare, environmental monitoring, and food safety. Researchers have developed innovative sensing platforms for detecting pathogens, pollutants, and contaminants by leveraging the paper's unique properties, such as biodegradability and affordability. These portable, low-cost sensors facilitate rapid diagnostics and on-site analysis, making them invaluable tools for resource-limited settings. This review discusses the fabrication techniques, principles, and applications of paper microfluidics, showcasing its potential to address pressing challenges and enhance human health and environmental sustainability.
Collapse
Affiliation(s)
- Sanjay Kumar
- Durham School of Architectural Engineering and Construction, University of Nebraska-Lincoln, Scott Campus, Omaha, NE 68182-0816, USA
| | - Jyoti Bala Kaushal
- Department of Biochemistry and Molecular Biology, University of Nebraska Medical Center, Omaha, NE 68198, USA
| | - Heow Pueh Lee
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117575, Singapore;
| |
Collapse
|
9
|
Jiang W, Tang Q, Zhu Y, Gu X, Wu L, Qin Y. Research progress of microfluidics-based food safety detection. Food Chem 2024; 441:138319. [PMID: 38218144 DOI: 10.1016/j.foodchem.2023.138319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/17/2023] [Accepted: 12/27/2023] [Indexed: 01/15/2024]
Abstract
High demands for food safety detection and analysis have been advocated with people's increasing living standards. Even though numerous analytical testing techniques have been proposed, their widespread adoption is still constrained by the high limit of detection, narrow detection ranges, and high implementation costs. Due to their advantages, such as reduced sample and reagent consumption, high sensitivity, automation, low cost, and portability, using microfluidic devices for food safety monitoring has generated significant interest. This review provides a comprehensive overview of the latest microfluidic detection platforms (published in recent 4 years) and their applications in food safety, aiming to provide references for developing efficient research strategies for food contaminant detection and facilitating the transition of these platforms from laboratory research to practical field use.
Collapse
Affiliation(s)
- Wenjun Jiang
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China
| | - Qu Tang
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China
| | - Yidan Zhu
- Medical School, Nantong University, Nantong, Jiangsu 226001, PR China
| | - Xijuan Gu
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China
| | - Li Wu
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China; School of Life Science, Nantong University, Nantong, Jiangsu 226001, PR China.
| | - Yuling Qin
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China.
| |
Collapse
|
10
|
Song J, Zhao B, Wang Y, Liu X, Cheng Z, Zhang X, Feng X. A portable smartphone-assisted Tb-MOF-based agar-slice probe for the rapid and on-site fluorescence assay of malachite green in aquatic products. Food Chem 2024; 437:137883. [PMID: 37918152 DOI: 10.1016/j.foodchem.2023.137883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 10/25/2023] [Accepted: 10/26/2023] [Indexed: 11/04/2023]
Abstract
In this study, a new Tb-MOF fluorescence probe was developed for the detection of malachite green (MG) in real aquatic products. Fluorescence sensing experiments revealed that MG can effectively quench the green fluorescence of Tb-MOF suspensions, and the detection process exhibits the advantages of high sensitivity, a wide linear range (0-80 μM), a low detection limit (10.8 nM) and a rapid response time. Selective detection of MG is achieved primarily through fluorescence resonance energy transfer (FRET) and photoinduced electron transfer (PET) mechanisms. Furthermore, a smartphone-assisted Tb-MOF-based agar slice detection platform was constructed for the visual and quantitative detection of MG. Additionally, the on-site detection of MG in crucian and shrimp samples was accomplished with high recoveries (99.8 %-107.99 %) and low relative standard deviations (RSD < 2.2 %). This developed detection platform introduced a low-cost, portable and user-friendly approach for MG detection.
Collapse
Affiliation(s)
- Junya Song
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang 471934, China; College of Food and Bioengineering, Henan University of Science and Technology, Luoyang 471022, China
| | - Beibei Zhao
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang 471934, China; College of Food and Bioengineering, Henan University of Science and Technology, Luoyang 471022, China
| | - Yiren Wang
- College of Horticulture and Plant Protection, Henan University of Science and Technology, Luoyang 471022, China
| | - Xinfang Liu
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang 471934, China.
| | - Zheng Cheng
- College of Food and Bioengineering, Henan University of Science and Technology, Luoyang 471022, China
| | - Xiaoyu Zhang
- College of Food and Bioengineering, Henan University of Science and Technology, Luoyang 471022, China.
| | - Xun Feng
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang 471934, China
| |
Collapse
|
11
|
Ye T, Chen H, Bai L, Yuan M, Cao H, Hao L, Wu X, Yin F, Xu F. A colorimetric and fluorescent dual-mode sensor based on bifunctional G-quadruplex-hemin complex for the determination of Pb 2. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 309:123807. [PMID: 38154306 DOI: 10.1016/j.saa.2023.123807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 12/18/2023] [Accepted: 12/21/2023] [Indexed: 12/30/2023]
Abstract
Due to the threat of lead pollution to health, environmental and food safety, developing simple and fast detection methods is highly required. Whereas, traditional single-mode probe suffers from limited application scenario. In this study, a colorimetric and fluorometric dual-mode probe for Pb2+ determination was constructed by using bifunctional G-quadruplex-hemin complex. In this dual-mode probe, enzyme strand and substrate strand of 8-17 DNAzyme are labeled with G-quadruplex-hemin complex and fluorophore, respectively. In the absence of Pb2+, the self-assembly of enzyme strand and substrate strand inhibits intrinsic mimic peroxidase of G-quadruplex-hemin complex by base-pairing, which also quench the fluorescence via in proximity effect. When the DNAzyme is activated by Pb2+, the quenched fluorescence is restored as well as the inherent peroxidase mimetic activity, leading to dual signal output. Under optimal conditions, this dual-mode probe exhibit a good linear relationship between logarithm of Pb2+ concentration and signal difference within the range from 1.5 nM to 20 nM and 0.5 nM to 10 nM for colorimetric and fluorescence mode, respectively. The detection limits for the corresponding mode were estimated to be 1.29 nM and 0.16 nM, respectively. This dual-mode probe also successfully applied for the spiked river water assay with satisfactory recovery in the range of 93.2 %-115.3 %. This work paves a new way for DNAzyme based dual-mode probe construction.
Collapse
Affiliation(s)
- Tai Ye
- Shanghai Engineering Research Center for Food Rapid Detection, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Haohao Chen
- Shanghai Engineering Research Center for Food Rapid Detection, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Long Bai
- Shanghai Engineering Research Center for Food Rapid Detection, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Min Yuan
- Shanghai Engineering Research Center for Food Rapid Detection, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Hui Cao
- Shanghai Engineering Research Center for Food Rapid Detection, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Liling Hao
- Shanghai Engineering Research Center for Food Rapid Detection, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Xiuxiu Wu
- Shanghai Engineering Research Center for Food Rapid Detection, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Fengqin Yin
- Shanghai Engineering Research Center for Food Rapid Detection, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Fei Xu
- Shanghai Engineering Research Center for Food Rapid Detection, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
| |
Collapse
|
12
|
Aryal P, Hefner C, Martinez B, Henry CS. Microfluidics in environmental analysis: advancements, challenges, and future prospects for rapid and efficient monitoring. LAB ON A CHIP 2024; 24:1175-1206. [PMID: 38165815 DOI: 10.1039/d3lc00871a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Microfluidic devices have emerged as advantageous tools for detecting environmental contaminants due to their portability, ease of use, cost-effectiveness, and rapid response capabilities. These devices have wide-ranging applications in environmental monitoring of air, water, and soil matrices, and have also been applied to agricultural monitoring. Although several previous reviews have explored microfluidic devices' utility, this paper presents an up-to-date account of the latest advancements in this field for environmental monitoring, looking back at the past five years. In this review, we discuss devices for prominent contaminants such as heavy metals, pesticides, nutrients, microorganisms, per- and polyfluoroalkyl substances (PFAS), etc. We cover numerous detection methods (electrochemical, colorimetric, fluorescent, etc.) and critically assess the current state of microfluidic devices for environmental monitoring, highlighting both their successes and limitations. Moreover, we propose potential strategies to mitigate these limitations and offer valuable insights into future research and development directions.
Collapse
Affiliation(s)
- Prakash Aryal
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
| | - Claire Hefner
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
| | - Brandaise Martinez
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
13
|
Gong Q, Xu X, Cheng Y, Wang X, Liu D, Nie G. A novel "on-off-on" electrochemiluminescence strategy based on RNA cleavage propelled signal amplification and resonance energy transfer for Pb 2+ detection. Anal Chim Acta 2024; 1290:342218. [PMID: 38246744 DOI: 10.1016/j.aca.2024.342218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/02/2024] [Accepted: 01/04/2024] [Indexed: 01/23/2024]
Abstract
BACKGROUND Lead (Pb) is one of the most toxic heavy-metal pollutants. Additionally, lead ions (Pb2+) can accumulate in the human body through the food chain, causing irreversible damage through organ damage and system disorders. In the past few years, the detection of Pb2+ has mainly relied on instrumental methods such as atomic absorption spectroscopy (AAS) and inductively coupled plasma mass spectrometry (ICP-MS). Nonetheless, these techniques are complicated in terms of equipment and procedures, along with being time-intensive and expensive in terms of detection. These drawbacks have limited their wide application. Hence, there is a pressing need to develop detection techniques for Pb2+ that are not only cost-efficient but also highly sensitive and specific. RESULTS A novel "on-off-on" electrochemiluminescence (ECL) sensor for detecting Pb2+ was developed based on the resonance energy transfer (RET) effect between AuNPs and boron nitride quantum dots (BN QDs) and the recognition of Pb2+ by DNAzyme along with the cleavage reaction of the substrate chain. Poly(6-carboxyindole)/stannic sulfide (P6ICA/SnS2) nanocomposite was employed as a co-reaction accelerator to consequently facilitate the production of intermediate SO4•-. This effective enhancement of the reaction led to an improved ECL intensity of BN QDs and enabled the sensor platform to exhibit a higher original ECL response. Benefiting from the combination of the DNAzyme signal amplification strategy with the "on-off-on" design, the ECL sensor showed satisfactory selectivity, good stability, and high sensitivity. This ECL sensor exhibited a linear detection range (LDR) of 10-12-10-5 M and a limit of detection (LOD) of 2.6 × 10-13 M. SIGNIFICANCE In the present work, an "on-off-on" ECL sensor is constructed based on RET effect for ultrasensitive detection of Pb2+. P6ICA/SnS2 was investigated as the co-reaction accelerator in this sensor. Moreover, this ECL sensor exhibited excellent analytical capability for detecting Pb2+ in actual water samples, providing a method for detecting other heavy metal ions as well.
Collapse
Affiliation(s)
- Qinghua Gong
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, State Key Laboratory Base of Eco-chemical Engineering, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Xuejiao Xu
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, State Key Laboratory Base of Eco-chemical Engineering, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Yanmei Cheng
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, State Key Laboratory Base of Eco-chemical Engineering, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Xianhong Wang
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, State Key Laboratory Base of Eco-chemical Engineering, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Dandan Liu
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, State Key Laboratory Base of Eco-chemical Engineering, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Guangming Nie
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, State Key Laboratory Base of Eco-chemical Engineering, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| |
Collapse
|
14
|
Wen J, Deng H, He D, Yuan Y. Dual-functional DNAzyme powered CRISPR-Cas12a sensor for ultrasensitive and high-throughput detection of Pb 2+ in freshwater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 911:168708. [PMID: 37992834 DOI: 10.1016/j.scitotenv.2023.168708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 11/17/2023] [Accepted: 11/17/2023] [Indexed: 11/24/2023]
Abstract
Freshwater lead pollution has posed severe threat to the environment and human health, underscoring the urgent necessity for accurate and user-friendly detection methods. Herein, we introduce a novel Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR-Cas) sensor for highly sensitive Pb2+ detection. To accomplish this, we designed a dual-functional deoxyribozyme (df-DNAzyme) probe that functions as an activator for the CRISPR-Cas12a system while also recognizing Pb2+. The df-DNAzyme probe was subsequently combined with gold nanoparticles (AuNPs) to fabricate a DNAzyme/AuNP nanoprobe, facilitating the activation of CRISPR-Cas12a in a one-to-multiple manner. Upon exposure to Pb2+, the df-DNAzyme is cleaved, causing disintegration of the DNAzyme/AuNP nanoprobe from magnetic beads. The degraded DNAzyme/AuNP containing multiple double-stranded DNA activators efficiently triggers CRISPR-Cas12a activity, initiating cleavage of fluorescence-quenched reporter DNA and generating amplified signals accordingly. The amplified fluorescence signal is accurately quantified using a quantitative polymerase chain reaction (qPCR) instrument capable of measuring 96 or 384 samples simultaneously at the microliter scale. This technique demonstrates ultra-sensitive detection capability for Pb2+ at concentrations as low as 1 pg/L within a range from 1 pg/L to 10 μg/L, surpassing limits set by World Health Organization (WHO) and United States Environmental Protection Agency (US EPA) guidelines. This study offers an ultrasensitive and high-throughput method for the detection of Pb2+ in freshwater, thereby advancing a novel approach towards the development of precise and convenient techniques for detecting harmful contaminants.
Collapse
Affiliation(s)
- Junlin Wen
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China.
| | - Hongjie Deng
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China
| | - Daigui He
- Guangdong Mechanical & Electrical Polytechnic, Guangzhou 510550, China
| | - Yong Yuan
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China.
| |
Collapse
|
15
|
Hou X, Cheng Q, Wang H. Self-cleaning paper-based microfluidic biosensor employing DNAzyme and semiconducting single-walled carbon nanotube for copper ion detection. Bioelectrochemistry 2024; 155:108602. [PMID: 37972506 DOI: 10.1016/j.bioelechem.2023.108602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 11/06/2023] [Accepted: 11/07/2023] [Indexed: 11/19/2023]
Abstract
Microfluidic paper-based analytical device (μPAD) offers a simple and efficient platform for point-of-care monitoring, which can be beneficial for copper determination in livestock feed and manure. However, common cellulose paper has excellent hydrophilicity, causing μPAD is accompanied by poor mechanical properties, short service life, and low sensitivity. Here, a self-cleaning paper-based microfluidic biosensor for Cu2+ determination was proposed to overcome the mentioned shortages in the application. Polymeric octadecyl trichlorosilane was synthesized and decorated on cellulose paper to form hydrophobic paper, which can improve the hydrophobicity, self-cleaning, and pollution ability. In addition, hydrophobic paper, semiconducting single-walled carbon nanotube, and DNAzyme through the chemical bond were employed to fabricate a self-cleaning paper-based microfluidic biosensor. The properties were investigated using scanning electron microscopy, Raman, and electrochemical methods. The detecting parameters were also optimized. It could measure the Cu2+ concentration from 1 nM to 100 μM, and the detection limit was 0.65 nM. The self-cleaning paper-based microfluidic biosensor was applied to detect Cu2+ concentration in livestock feed and manure that can meet the requirements for fast screening and detection.
Collapse
Affiliation(s)
- Xiaopeng Hou
- Research Institute of Wood Industry, Chinese Academy of Forestry, Beijing 100091, PR China
| | - Qiongyi Cheng
- Academy of Agricultural Planning and Engineering, No. 41, Maizidian Street, Chaoyang District, Beijing 100125, PR China
| | - Hui Wang
- Research Institute of Wood Industry, Chinese Academy of Forestry, Beijing 100091, PR China; State Key Laboratory of Animal Nutrition and Feeding, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China.
| |
Collapse
|
16
|
Zhao B, Liu X, Fan J, Luo L, Zhang X, Li R, Feng X. An intelligent smartphone-test strip detection platform for rapid and on-site sensing of benzoyl peroxide in flour samples. Talanta 2023; 265:124877. [PMID: 37385188 DOI: 10.1016/j.talanta.2023.124877] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/19/2023] [Accepted: 06/21/2023] [Indexed: 07/01/2023]
Abstract
Benzoyl peroxide (BPO) is a commonly used flour whitener, but its excessive usage can have adverse effects on human health, such as nutrient loss, vitamin deficiencies and certain diseases. In this study, a europium metal organic framework (Eu-MOF) fluorescence probe was prepared, which exhibited a strong fluorescence emission at 614 nm upon excitation at 320 nm, with a high quantum yield of 8.11%. The red fluorescence of the probe could be effectively quenched by BPO through the inner filter effect (IFE) and photoinduced electron transfer (PET) mechanism. The detection process offered several advantages, including a wide linear range of 0-0.95 mM, a low detection limit of 66 nM and a fast fluorescence response of 2 min. Furthermore, an intelligent detection platform was designed to enhance the practical application of the detection method. This platform combined the portability and visuality of a traditional test strip with the color recognition capability of a smartphone, allowing for the visualization and quantitative detection of BPO in a convenient and user-friendly manner. The detection platform was successfully applied to the analysis of BPO in real flour samples with satisfactory recoveries (99.79%-103.94%), suggesting a promising strategy for the rapid and on-site detection of BPO in food samples.
Collapse
Affiliation(s)
- Beibei Zhao
- College of Food and Bioengineering, Henan University of Science and Technology, Luoyang, 471022, China; College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, China
| | - Xinfang Liu
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, China.
| | - Jinling Fan
- College of Food and Bioengineering, Henan University of Science and Technology, Luoyang, 471022, China
| | - Lei Luo
- College of Food and Bioengineering, Henan University of Science and Technology, Luoyang, 471022, China
| | - Xiaoyu Zhang
- College of Food and Bioengineering, Henan University of Science and Technology, Luoyang, 471022, China.
| | - Rongfang Li
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, China
| | - Xun Feng
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, China
| |
Collapse
|
17
|
Esmaelpourfarkhani M, Ramezani M, Alibolandi M, Abnous K, Taghdisi SM. Label-free colorimetric sensor for Pb 2+ determination using catalytic activity of MnO 2 nanoflowers and elongated aptamer. Anal Biochem 2023; 678:115286. [PMID: 37591336 DOI: 10.1016/j.ab.2023.115286] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/12/2023] [Accepted: 08/14/2023] [Indexed: 08/19/2023]
Abstract
In this study, a label-free aptasensor utilizing colorimetric properties was developed to detect Pb2+ with high sensitivity. The approach involved applying modified aptamer which enhanced the oxidase-mimicking activity of MnO2 nanoflowers. This innovative method provides an efficient means for monitoring Pb2+ ions without requiring any labeling techniques. The fundamental principle of this aptasensor is based on the adsorption of a modified aptamer onto MnO2 nanoflowers' surface, which in turn increases their affinity for chromogenic substrates and enhances their catalytic activity. The proposed aptasensor exploits the high sensitivity due to the extension of the aptamer sequence length by terminal deoxynucleotidyl transferase (TdT). Under optimum experimental conditions, the developed colorimetric aptasensor indicated a linear detection range from 4 to 80 nM with a limit of detection (LOD) of 1.4 nM. Moreover, the aptasensor successfully monitored Pb2+ in the drinking water, milk and human serum samples. Henceforth, the colorimetric aptasensor exhibited in this study possesses several benefits such as uncomplicated operation, cost-effectiveness, label-free detection and remarkable sensitivity. Thus rendering it a suitable option for analyzing intricate samples.
Collapse
Affiliation(s)
- Masoomeh Esmaelpourfarkhani
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Ramezani
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mona Alibolandi
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Khalil Abnous
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Seyed Mohammad Taghdisi
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
18
|
Gao J, Xu P, Qiao L, Tao Y, Xiao Y, Qin H, Zhu Y, Zhang Y. Triplex DNA Helix Sensor Based on Reduced Graphene Oxide and Electrodeposited Gold Nanoparticles for Sensitive Lead(II) Detection. TOXICS 2023; 11:795. [PMID: 37755805 PMCID: PMC10536607 DOI: 10.3390/toxics11090795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 09/16/2023] [Accepted: 09/18/2023] [Indexed: 09/28/2023]
Abstract
A triplex DNA electrochemical sensor based on reduced graphene oxide (rGO) and electrodeposited gold nanoparticles (EAu) was simply fabricated for Pb2+ detection. The glass carbon electrode (GCE) sequentially electrodeposited with rGO and EAu was further modified with a triplex DNA helix that consisted of a guanine (G)-rich circle and a stem of triplex helix based on T-A•T base triplets. With the existence of Pb2+, the DNA configuration which was formed via the Watson-Crick and Hoogsteen base pairings was split and transformed into a G-quadruplex. An adequate electrochemical response signal was provided by the signal indicator methylene blue (MB). The proposed sensor demonstrated a linear relationship between the differential pulse voltammetry (DPV) peak currents and the logarithm of Pb2+ concentrations from 0.01 to 100.00 μM with a detection limit of 0.36 nM. The proposed sensor was also tested with tap water, river and medical wastewater samples with qualified recovery and accuracy and represented a promising method for Pb2+ detection.
Collapse
Affiliation(s)
- Jing Gao
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China; (J.G.); (P.X.); (L.Q.); (Y.T.); (Y.X.); (H.Q.)
- Key Laboratory of Environmental Biology and Pollution Control, Ministry of Education, Hunan University, Changsha 410082, China
| | - Piao Xu
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China; (J.G.); (P.X.); (L.Q.); (Y.T.); (Y.X.); (H.Q.)
- Key Laboratory of Environmental Biology and Pollution Control, Ministry of Education, Hunan University, Changsha 410082, China
| | - Lu Qiao
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China; (J.G.); (P.X.); (L.Q.); (Y.T.); (Y.X.); (H.Q.)
- Key Laboratory of Environmental Biology and Pollution Control, Ministry of Education, Hunan University, Changsha 410082, China
| | - Yani Tao
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China; (J.G.); (P.X.); (L.Q.); (Y.T.); (Y.X.); (H.Q.)
- Key Laboratory of Environmental Biology and Pollution Control, Ministry of Education, Hunan University, Changsha 410082, China
| | - Yao Xiao
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China; (J.G.); (P.X.); (L.Q.); (Y.T.); (Y.X.); (H.Q.)
- Key Laboratory of Environmental Biology and Pollution Control, Ministry of Education, Hunan University, Changsha 410082, China
| | - Hong Qin
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China; (J.G.); (P.X.); (L.Q.); (Y.T.); (Y.X.); (H.Q.)
- Key Laboratory of Environmental Biology and Pollution Control, Ministry of Education, Hunan University, Changsha 410082, China
| | - Yuan Zhu
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China; (J.G.); (P.X.); (L.Q.); (Y.T.); (Y.X.); (H.Q.)
- Key Laboratory of Environmental Biology and Pollution Control, Ministry of Education, Hunan University, Changsha 410082, China
| | - Yi Zhang
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China; (J.G.); (P.X.); (L.Q.); (Y.T.); (Y.X.); (H.Q.)
- Key Laboratory of Environmental Biology and Pollution Control, Ministry of Education, Hunan University, Changsha 410082, China
| |
Collapse
|
19
|
Wei X, Ma P, Imran Mahmood K, Zhang Y, Wang Z. Screening of a High-Affinity Aptamer for Aflatoxin M 1 and Development of Its Colorimetric Aptasensor. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2023; 71:7546-7556. [PMID: 37144950 DOI: 10.1021/acs.jafc.3c01586] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Aflatoxin M1 (AFM1), a secondary metabolite of Aspergillus spp., is highly toxic and widely present in food matrices. Therefore, the detection of AFM1 is of great importance for the protection of food safety. In this study, a five-segment sequence was designed as the initial library. Graphene oxide-SELEX (GO-SELEX) was applied to screen AFM1. After seven rounds of repeated screening, affinity and specificity assays showed that aptamer 9 was the best candidate for AFM1. The dissociation constant (Kd) of aptamer 9 was 109.10 ± 6.02 nM. To verify the efficiency and sensitivity aptamer for the detection of AFM1, a colorimetric sensor based on the aptamer was constructed. The biosensor showed good linearity in the range of AFM1 concentration of 0.5-500.0 ng/mL with a detection limit of 0.50 ng/mL. This colorimetric method was successfully used for the detection of AFM1 in milk powder samples. Its detection recovery was 92.8-105.2%. This study was conducted to provide a reference for the detection of AFM1 in food.
Collapse
Affiliation(s)
- Xunjiao Wei
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi 214122, China
- School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
- International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China
| | - Pengfei Ma
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi 214122, China
- School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
- International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China
| | - Khan Imran Mahmood
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi 214122, China
- School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
- National Engineering Research Center for Functional Food, Jiangnan University, Wuxi, Jiangsu 214122, China
| | - Yin Zhang
- Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu 610106, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi 214122, China
- School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
- National Engineering Research Center for Functional Food, Jiangnan University, Wuxi, Jiangsu 214122, China
- International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China
- Collaborative Innovation Center of Food Safety and Quality Control of Jiangsu Province, Jiangnan University, Wuxi 214122, China
| |
Collapse
|