1
|
Pan Y, Wan Y, Wu Y, Lin C, Ye Q, Liu J, Jiang H, Wang H, Wang Y. Radiomics models based on thoracic and upper lumbar spine in chest LDCT to predict low bone mineral density. Sci Rep 2024; 14:31323. [PMID: 39732811 DOI: 10.1038/s41598-024-82642-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Accepted: 12/06/2024] [Indexed: 12/30/2024] Open
Abstract
This study aims to develop and validate different radiomics models based on thoracic and upper lumbar spine in chest low-dose computed tomography (LDCT) to predict low bone mineral density (BMD) using quantitative computed tomography (QCT) as standard of reference. A total of 905 participants underwent chest LDCT and paired QCT BMD examination were retrospectively included from August 2018 and June 2019. The patients with low BMD (n = 388) and the normal (n = 517) were randomly divided into a training set (n = 622) and a validation set (n = 283). Radiomics features (RFs) were extracted from the single and consecutive vertebrae in chest LDCT images to construct the single vertebra RFs models, mixed RFs models and Radscore models, respectively. The performance of these models was evaluated by the area under the curve (AUC) of receiver operator characteristic curve, using QCT as standard of reference. The Radscore models, mixed RFs models, and single vertebra RFs models yielded the AUC values ranging from 0.809 to 0.906, 0.792 to 0.883, and 0.731 to 0.884 for predicting low BMD in the validation set, respectively. For predicting low BMD, the Radscore model of L1-L2 vertebrae yielded the highest AUC of 0.906, and of T1-T3 yielded the lowest AUC of 0.809 (P < 0.05), respectively. However, there was no significant difference among the AUC values of three Radscore models constructed on the vertebrae of T4-T6 (AUC = 0.855), T7-T9 (AUC = 0.845), and T10-T12 (AUC = 0.871) for predicting low BMD in the validation set (P > 0.1). The Radscore model of L1-L2 have potential to serve as an important tool for predicting and screening low BMD from normal in chest LDCT images.
Collapse
Affiliation(s)
- Yaling Pan
- Center for Rehabilitation Medicine, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, 310014, Zhejiang, China
| | - Yidong Wan
- HiThink Research, Hangzhou, 310023, Zhejiang, China
- Zhejiang Herymed Technology Co., Ltd., Hangzhou, 310023, Zhejiang, China
| | - Yinbo Wu
- Center for Rehabilitation Medicine, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, 310014, Zhejiang, China
| | - Chunmiao Lin
- Center for Rehabilitation Medicine, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, 310014, Zhejiang, China
| | - Qin Ye
- Center for Rehabilitation Medicine, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, 310014, Zhejiang, China
| | - Jing Liu
- Center for Rehabilitation Medicine, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, 310014, Zhejiang, China
| | - Hongyang Jiang
- Center for Rehabilitation Medicine, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, 310014, Zhejiang, China
| | - Huogen Wang
- HiThink Research, Hangzhou, 310023, Zhejiang, China.
- Zhejiang Herymed Technology Co., Ltd., Hangzhou, 310023, Zhejiang, China.
| | - Yajie Wang
- Center for Rehabilitation Medicine, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, 310014, Zhejiang, China.
| |
Collapse
|
2
|
Chen J, Liu S, Lin Y, Hu W, Shi H, Liao N, Zhou M, Gao W, Chen Y, Shi P. The quality and accuracy of radiomics model in diagnosing osteoporosis: a systematic review and meta-analysis. Acad Radiol 2024:S1076-6332(24)00940-1. [PMID: 39701845 DOI: 10.1016/j.acra.2024.11.065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2024] [Revised: 11/05/2024] [Accepted: 11/25/2024] [Indexed: 12/21/2024]
Abstract
RATIONALE AND OBJECTIVES The purpose of this study is to conduct a meta-analysis to evaluate the diagnostic performance of current radiomics models for diagnosing osteoporosis, as well as to assess the methodology and reporting quality of these radiomics studies. METHODS According to PRISMA guidelines, four databases including MEDLINE, Web of Science, Embase and the Cochrane Library were searched systematically to select relevant studies published before July 18, 2024. The articles that used radiomics models for diagnosing osteoporosis were considered eligible. The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and radiomics quality score (RQS) were used to assess the quality of included studies. The pooled diagnostic odds ratio (DOR), sensitivity, specificity, area under the summary receiver operator characteristic curve (AUC) were calculated to estimated diagnostic efficiency of pooled model. RESULTS A total of 25 studies were included, of which 24 provided usable data that were utilized for the meta-analysis, including 1553 patients with osteoporosis and 2200 patients without osteoporosis. The mean RQS score of included studies was 11.48 ± 4.92, with an adherence rate of 31.89%. The pooled DOR, sensitivity and specificity for model to diagnose osteoporosis were 81.72 (95% CI: 51.08 - 130.73), 0.90 (95% CI: 0.87-0.93) and 0.90 (95% CI: 0.87-0.93), respectively. The AUC was 0.96, indicating a high diagnostic capability. Subgroup analysis revealed that the use of different imaging modalities to construct radiomics models might be one source of heterogeneity. Radiomics models built using CT images and deep learning algorithms demonstrated higher diagnostic accuracy for osteoporosis. CONCLUSION Radiomics models for the diagnosis of osteoporosis have high diagnostic efficacy. In the future, radiomics models for diagnosing osteoporosis will be an efficient instrument to assist clinical doctors in screening osteoporosis patients. However, relevant guidelines should be followed strictly to improve the quality of radiomics studies.
Collapse
Affiliation(s)
- Jianan Chen
- Department of Orthopedics, Sun Yat-Sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, PR China (J.C., S.L., Y.L., W.H., H.S., N.L., W.G., Y.C.)
| | - Song Liu
- Department of Orthopedics, Sun Yat-Sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, PR China (J.C., S.L., Y.L., W.H., H.S., N.L., W.G., Y.C.)
| | - Youxi Lin
- Department of Orthopedics, Sun Yat-Sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, PR China (J.C., S.L., Y.L., W.H., H.S., N.L., W.G., Y.C.)
| | - Wenjun Hu
- Department of Orthopedics, Sun Yat-Sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, PR China (J.C., S.L., Y.L., W.H., H.S., N.L., W.G., Y.C.)
| | - Huihong Shi
- Department of Orthopedics, Sun Yat-Sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, PR China (J.C., S.L., Y.L., W.H., H.S., N.L., W.G., Y.C.)
| | - Nianchun Liao
- Department of Orthopedics, Sun Yat-Sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, PR China (J.C., S.L., Y.L., W.H., H.S., N.L., W.G., Y.C.)
| | - Miaomiao Zhou
- Department of Endocrinology, People's Hospital of Dingbian, Dingbian, Shanxi, PR China (M.Z.)
| | - Wenjie Gao
- Department of Orthopedics, Sun Yat-Sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, PR China (J.C., S.L., Y.L., W.H., H.S., N.L., W.G., Y.C.)
| | - Yanbo Chen
- Department of Orthopedics, Sun Yat-Sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong, PR China (J.C., S.L., Y.L., W.H., H.S., N.L., W.G., Y.C.)
| | - Peijie Shi
- Department of Endocrinology, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong, PR China (P.S.).
| |
Collapse
|
3
|
Yang Y, Yuan Z, Ren Q, Wang J, Guan S, Tang X, Jiang Q, Meng X. Machine Learning-Enabled Fuhrman Grade in Clear-cell Renal Carcinoma Prediction Using Two-dimensional Ultrasound Images. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:1911-1918. [PMID: 39317624 DOI: 10.1016/j.ultrasmedbio.2024.08.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 08/22/2024] [Accepted: 08/24/2024] [Indexed: 09/26/2024]
Abstract
OBJECTIVE Accurate assessment of Fuhrman grade is crucial for optimal clinical management and personalized treatment strategies in patients with clear cell renal cell carcinoma (CCRCC). In this study, we developed a predictive model using ultrasound (US) images to accurately predict the Fuhrman grade. METHODS Between March 2013 and July 2023, a retrospective analysis was conducted on the US imaging and clinical data of 235 patients with pathologically confirmed CCRCC, including 67 with Fuhrman grades Ⅲ and Ⅳ. This study included 201 patients from Hospital A who were divided into training set (n = 161) and an internal validation set (n = 40) in an 8:2 ratio. Additionally, 34 patients from Hospital B were included for external validation. US images were delineated using ITK software, and radiomics features were extracted using PyRadiomics software. Subsequently, separate models for clinical factors, radiomics features, and their combinations were constructed. The model's performance was assessed by calculating the area under the receiver operating characteristic curve (AUC), calibration curve and decision curve analysis (DCA). RESULTS In total, 235 patients diagnosed with CCRCC, comprising 168 low-grade and 67 high-grade tumors, were included in this study. A comparison of the predictive performances of different models revealed that the logistic regression model exhibited relatively good stability and robustness. The AUC of the combined model for the training, internal validation and external validation sets were 0.871, 0.785 and 0.826, respectively, which were higher than those of the clinical and imaging histology models. Furthermore, the calibration curve demonstrated excellent concordance between the predicted Fuhrman grade probability of CCRCC using the combined model and the observed values in both the training and validation sets. Additionally, within the threshold range of 0-0.93, the combined model demonstrated substantial clinical utility, as evidenced by DCA. CONCLUSION The application of US radiomics techniques enabled objective prediction of Fuhrman grading in patients with CCRCC. Nevertheless, certain clinical indicators remain indispensable, underscoring the pressing need for their integrated use in clinical practice. ADVANCES IN KNOWLEDGE Previous studies have predominantly focused on using computed tomography or magnetic resonance imaging modalities to predict the Fuhrman grade of CCRCC. Our findings demonstrate that a prediction model based on US images is more cost-effective, easily accessible and exhibits commendable performance. Consequently, this study offers a promising approach to maximizing the use of US examinations in future research.
Collapse
Affiliation(s)
- Youchang Yang
- Department of Radiology, Qingdao Medical and Industrial Cross Key Laboratory, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, Shandong, China
| | - Ziyi Yuan
- School of Medicine, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Qingguo Ren
- Department of Radiology, Qingdao Medical and Industrial Cross Key Laboratory, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, Shandong, China
| | - Jiajia Wang
- School of Medicine, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Shuai Guan
- Department of Radiology, Qingdao Medical and Industrial Cross Key Laboratory, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, Shandong, China
| | - Xiaoqiang Tang
- Department of Radiology, The Affiliated Changzhou No. 2 People's Hospital of Nanjing Medical University, Changzhou, China
| | - Qingjun Jiang
- Department of Radiology, Qingdao Medical and Industrial Cross Key Laboratory, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, Shandong, China
| | - Xiangshui Meng
- Department of Radiology, Qingdao Medical and Industrial Cross Key Laboratory, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, Shandong, China.
| |
Collapse
|
4
|
Saravi B, Zink A, Tabukashvili E, Güzel HE, Ülkümen S, Couillard-Despres S, Lang GM, Hassel F. Integrating radiomics with clinical data for enhanced prediction of vertebral fracture risk. Front Bioeng Biotechnol 2024; 12:1485364. [PMID: 39650236 PMCID: PMC11620855 DOI: 10.3389/fbioe.2024.1485364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2024] [Accepted: 11/11/2024] [Indexed: 12/11/2024] Open
Abstract
Introduction Osteoporotic vertebral fractures are a major cause of morbidity, disability, and mortality among the elderly. Traditional methods for fracture risk assessment, such as dual-energy X-ray absorptiometry (DXA), may not fully capture the complex factors contributing to fracture risk. This study aims to enhance vertebral fracture risk prediction by integrating radiomics features extracted from computed tomography (CT) scans with clinical data, utilizing advanced machine learning techniques. Methods We analyzed CT imaging data and clinical records from 124 patients, extracting a comprehensive set of radiomics features. The dataset included shape, texture, and intensity metrics from segmented vertebrae, alongside clinical variables such as age and DXA T-values. Feature selection was conducted using a Random Forest model, and the predictive performance of multiple machine learning models-Random Forest, Gradient Boosting, Support Vector Machines, and XGBoost-was evaluated. Outcomes included the number of fractures (N_Fx), mean fracture grade, and mean fracture shape. Incorporating radiomics features with clinical data significantly improved predictive accuracy across all outcomes. The XGBoost model demonstrated superior performance, achieving an R2 of 0.7620 for N_Fx prediction in the training set and 0.7291 in the validation set. Key radiomics features such as Dependence Entropy, Total Energy, and Surface Volume Ratio showed strong correlations with fracture outcomes. Notably, Dependence Entropy, which reflects the complexity of voxel intensity arrangements, was a critical predictor of fracture severity and number. Discussion This study underscores the potential of radiomics as a valuable tool for enhancing fracture risk assessment beyond traditional clinical methods. The integration of radiomics features with clinical data provides a more nuanced understanding of vertebral bone health, facilitating more accurate risk stratification and personalized management in osteoporosis care. Future research should focus on standardizing radiomics methodologies and validating these findings across diverse populations.
Collapse
Affiliation(s)
- Babak Saravi
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
- Department of Spine Surgery, Loretto Hospital, Freiburg, Germany
- Department of Radiology, Ministry of Health Izmir City Hospital, Izmir, Türkiye
| | - Alisia Zink
- Department of Spine Surgery, Loretto Hospital, Freiburg, Germany
| | | | - Hamza Eren Güzel
- Department of Radiology, Ministry of Health Izmir City Hospital, Izmir, Türkiye
| | - Sara Ülkümen
- Department of Spine Surgery, Loretto Hospital, Freiburg, Germany
| | - Sebastien Couillard-Despres
- Institute of Experimental Neuroregeneration, Paracelsus Medical University, Salzburg, Austria
- Austrian Cluster for Tissue Regeneration, Vienna, Austria
| | - Gernot Michael Lang
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Frank Hassel
- Department of Spine Surgery, Loretto Hospital, Freiburg, Germany
| |
Collapse
|
5
|
Mohammadi-Sadr M, Cheki M, Moslehi M, Zarasvandnia M, Salamat MR. A Novel Approach Based on Integrating Radiomics, Bone Morphometry and Hounsfield Unit-Derived From Routine Chest CT for Bone Mineral Density Assessment. Acad Radiol 2024:S1076-6332(24)00838-9. [PMID: 39562197 DOI: 10.1016/j.acra.2024.10.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2024] [Revised: 10/23/2024] [Accepted: 10/28/2024] [Indexed: 11/21/2024]
Abstract
RATIONALE AND OBJECTIVES The purpose of this study is the feasibility of using radiomics features, bone morphometry features (BM), and Hounsfield unit (HU) values obtained from routine chest computed tomography (CT) for assessing bone mineral density (BMD) status. MATERIALS AND METHODS This retrospective study analyzed 120 patients who underwent routine chest CT and dual-energy X-ray absorptiometry examinations within a month. Whole thoracic vertebral bodies from routine chest CT images were segmented using the GrowCut semi-automatic segmentation method, and radiomics features, BM features, and HU values were extracted. To assess the intra- and inter-observer variability of segmentation, the Dice similarity coefficient (DSC) was utilized. Feature selection was carried out using the intra-class correlation coefficient and the Boruta algorithm. Six machine learning classification models were employed for classification in a three-class manner. The models' performance was evaluated using the area under the receiver operator characteristics curve (AUC). Other evaluation parameters of the models were calculated, including overall accuracy, precision, and sensitivity. RESULTS The DSC values showed high similarity by achieving 0.907 ± 0.034 and 0.887 ± 0.048 for intra- and inter-observer segmentation agreement, respectively. After a two-stepwise feature selection, 21 radiomics features were selected. Different combinations of these radiomics features with five BM features and HU values were applied to six classification models for evaluating BMD. The multilayer perceptron (MLP) model based on integration of radiomics features and BM features in a three-class classification approach achieved higher performance compared to other models with an AUC of 0.981 (95% confidence interval (CI): 0.937-0.997) in normal BMD class, an AUC of 0.896 (95% CI: 0.826-0.944) in osteopenia class, and an AUC of 0.927 (95% CI: 0.866-0.967) in osteoporosis class. CONCLUSION Using the MLP classification model based on a combination of radiomics features and BM features in a three-class classification approach can effectively distinguish different BMD conditions.
Collapse
Affiliation(s)
- Mahmoud Mohammadi-Sadr
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran (M.M.S., M.M., M.R.S.)
| | - Mohsen Cheki
- Department of Medical Imaging and Radiation Sciences, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran (M.C., M.Z.)
| | - Masoud Moslehi
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran (M.M.S., M.M., M.R.S.)
| | - Marziyeh Zarasvandnia
- Department of Medical Imaging and Radiation Sciences, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran (M.C., M.Z.)
| | - Mohammad Reza Salamat
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran (M.M.S., M.M., M.R.S.).
| |
Collapse
|
6
|
Lin A, Zhang H, Wang Y, Cui Q, Zhu K, Zhou D, Han S, Meng S, Han J, Li L, Zhou C, Ma X. Radiomics based on MRI to predict recurrent L4-5 disc herniation after percutaneous endoscopic lumbar discectomy. BMC Med Imaging 2024; 24:273. [PMID: 39390384 PMCID: PMC11468133 DOI: 10.1186/s12880-024-01450-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 10/01/2024] [Indexed: 10/12/2024] Open
Abstract
BACKGROUND In recent years, radiomics has been shown to be an effective tool for the diagnosis and prediction of diseases. Existing evidence suggests that imaging features play a key role in predicting the recurrence of lumbar disk herniation (rLDH). Thus, this study aimed to evaluate the risk of rLDH in patients undergoing percutaneous endoscopic lumbar discectomy (PELD) using radiomics to facilitate the development of more rational surgical and perioperative management strategies. METHOD This was a retrospective case-control study involving 487 patients who underwent PELD at the L4/5 level. The rLDH and negative groups were matched using propensity score matching (PSM). A total of 1409 radiomic features were extracted from preoperative lumbar MRI images using intraclass correlation coefficient (ICC) analysis, t-test, and LASSO analysis. Afterward, 6 predictive models were constructed and evaluated using ROC curve analysis, AUC, specificity, sensitivity, confusion matrix, and 2 repeated 3-fold cross-validations. Lastly, the Shapley Additive Explanation (SHAP) analysis provided visual explanations for the models. RESULTS Following screening and matching, 128 patients were included in both the recurrence and control groups. Moreover, 18 of the extracted radiomic features were selected for generating six models, which achieved an AUC of 0.551-0.859 for predicting rLDH. Among these models, SVM, RF, and XG Boost exhibited superior performances. Finally, cross-validation revealed that their accuracy was 0.674-0.791, 0.647-0.729, and 0.674-0.718. CONCLUSION Radiomics based on MRI can be used to predict the risk of rLDH, offering more comprehensive guidance for perioperative treatment by extracting imaging information that cannot be visualized with the naked eye. Meanwhile, the accuracy and generalizability of the model can be improved in the future by incorporating more data and conducting multicenter studies.
Collapse
Affiliation(s)
- Antao Lin
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China
| | - Hao Zhang
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China
| | - Yan Wang
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China
| | - Qian Cui
- Department of Medical Imaging, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, People's Republic of China
| | - Kai Zhu
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China
| | - Dan Zhou
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China
| | - Shuo Han
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China
| | - Shengwei Meng
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China
| | - Jialuo Han
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China
| | - Lei Li
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China
| | - Chuanli Zhou
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China.
| | - Xuexiao Ma
- Department of Spinal Surgery, The Affiliated Hospital of Qingdao University, No.59 Haier Road, Qingdao, Shandong, 266000, People's Republic of China.
| |
Collapse
|
7
|
Deng L, Shuai P, Liu Y, Yong T, Liu Y, Li H, Zheng X. Diagnostic performance of radiomics for predicting osteoporosis in adults: a systematic review and meta-analysis. Osteoporos Int 2024; 35:1693-1707. [PMID: 38802557 DOI: 10.1007/s00198-024-07136-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Accepted: 05/16/2024] [Indexed: 05/29/2024]
Abstract
This study aimed to assess the diagnostic accuracy of radiomics for predicting osteoporosis and the quality of radiomic studies. The study protocol was prospectively registered on PROSPERO (CRD42023425058). We searched PubMed, EMBASE, Web of Science, and Cochrane Library databases from inception to June 1, 2023, for eligible articles that applied radiomic techniques to diagnosing osteoporosis or abnormal bone mass. Quality and risk of bias of the included studies were evaluated with radiomics quality score (RQS), METhodological RadiomICs Score (METRICS), and Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tools. The data analysis utilized the R program with mada, metafor, and meta packages. Ten retrospective studies with 5926 participants were included in the systematic review and meta-analysis. The overall risk of bias and applicability concerns for each domain of the studies were rated as low, except for one study which was considered to have a high risk of flow and time bias. The mean METRICS score was 70.1% (range 49.6-83.2%). There was moderate heterogeneity across studies and meta-regression identified sources of heterogeneity in the data, including imaging modality, feature selection method, and classifier. The pooled diagnostic odds ratio (DOR) under the bivariate random effects model across the studies was 57.22 (95% CI 27.62-118.52). The pooled sensitivity and specificity were 87% (95% CI 81-92%) and 87% (95% CI 77-93%), respectively. The area under the summary receiver operating characteristic curve (AUC) of the radiomic models was 0.94 (range 0.8 to 0.98). The results supported that the radiomic techniques had good accuracy in diagnosing osteoporosis or abnormal bone mass. The application of radiomics in osteoporosis diagnosis needs to be further confirmed by more prospective studies with rigorous adherence to existing guidelines and multicenter validation.
Collapse
Affiliation(s)
- Ling Deng
- Department of Health Management & Institute of Health Management, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China
| | - Ping Shuai
- Department of Health Management & Institute of Health Management, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China
| | - Youren Liu
- Department of Health Management & Institute of Health Management, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China
| | - Tao Yong
- Department of Medical Information Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China
| | - Yuping Liu
- Department of Health Management & Institute of Health Management, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China
| | - Hang Li
- Department of Radiology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China.
| | - Xiaoxia Zheng
- Department of Health Management & Institute of Health Management, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China.
| |
Collapse
|
8
|
Wang J, He Y, Yan L, Chen S, Zhang K. Predicting Osteoporosis and Osteopenia by Fusing Deep Transfer Learning Features and Classical Radiomics Features Based on Single-Source Dual-energy CT Imaging. Acad Radiol 2024; 31:4159-4170. [PMID: 38693026 DOI: 10.1016/j.acra.2024.04.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 04/14/2024] [Accepted: 04/14/2024] [Indexed: 05/03/2024]
Abstract
RATIONALE AND OBJECTIVES To develop and validate a predictive model for osteoporosis and osteopenia prediction by fusing deep transfer learning (DTL) features and classical radiomics features based on single-source dual-energy computed tomography (CT) virtual monochromatic imaging. METHODS A total of 606 lumbar vertebrae with dual-energy CT imaging and quantitative CT (QCT) evaluation were included in the retrospective study and randomly divided into the training (n = 424) and validation (n = 182) cohorts. Radiomics features and DTL features were extracted from 70-keV monochromatic CT images, followed by feature selection and model construction, radiomics and DTL features models were established. Then, we integrated the selected two types of features into a features fusion model. We developed a two-level classifier for the hierarchical pairwise classification of each vertebra. All the vertebrae were first classified into osteoporosis and non-osteoporosis groups, then non-osteoporosis group was classified into osteopenia and normal groups. QCT was used as reference. The predictive performance and clinical usefulness of three models were evaluated and compared. RESULTS The area under the curve (AUC) of the features fusion, radiomics and DTL models for the classification between osteoporosis and non-osteoporosis were 0.981, 0.999, 0.997 in the training cohort and 0.979, 0.943, 0.848 in the validation cohort. Furthermore, the AUCs of the previously mentioned models for the differentiation between osteopenia and normal were 0.994, 0.971, 0.996 in the training cohort and 0.990, 0.968, 0.908 in the validation cohort. The overall accuracy of the previously mentioned models for two-level classifications was 0.979, 0.955, 0.908 in the training cohort and 0.918, 0.885, 0.841 in the validation cohort. Decision curve analysis showed that all models had high clinical value. CONCLUSION The feature fusion model can be used for osteoporosis and osteopenia prediction with improved predictive ability over a radiomics model or a DTL model alone.
Collapse
Affiliation(s)
- Jinling Wang
- Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha 410007, PR China
| | - Yewen He
- Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha 410007, PR China
| | - Luyou Yan
- Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha 410007, PR China
| | - Suping Chen
- GE Healthcare (Shanghai) Co., Ltd., Shanghai 201203, PR China
| | - Kun Zhang
- Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha 410007, PR China; College of Integrated Traditional Chinese and Western Medicine, Hunan University of Chinese Medicine, 300 Xueshi Road, Yuelu District, Changsha 410208, PR China.
| |
Collapse
|
9
|
Kang SR, Wang K. Radiomic nomogram based on lumbar spine magnetic resonance images to diagnose osteoporosis. Acta Radiol 2024; 65:950-958. [PMID: 38651258 DOI: 10.1177/02841851241242052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
BACKGROUND We aimed to establish a novel model using a radiomics analysis of magnetic resonance (MR) images for predicting osteoporosis. PURPOSE To investigate the effectiveness of a radiomics approach utilizing magnetic resonance imaging (MRI) of the lumbar spine in identifying osteoporosis. MATERIAL AND METHODS In this retrospective study, a total of 291 patients who underwent MRI were analyzed. Radiomics features were extracted from the MRI scans of all 1455 lumbar vertebrae, and build the radiomics model based on T2-weighted (T2W), T1-weighted (T1W), and T2W + T1W imaging. The performance of the combined model was assessed using metrics such as the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and accuracy. The AUCs of these models were compared using the DeLong test. Their clinical usefulness was assessed using a decision curve analysis. RESULTS T2W, T1W, and T1W + T2W imaging retained 27, 27, and 17 non-zero coefficients, respectively. The AUCS about radiomics scores based on T2W, T1W, and T1W + T2W imaging were 0.894, 0.934, and 0.945, respectively, which all performed better than the clinical model significantly. The rad-signatures based on T1W + T2W imaging, which exhibited a stronger predictive power, were included in the creation of the nomogram for osteoporosis diagnosis, and the AUC was 0.965 (95% confidence interval (CI)=0.944-0.986) in the training cohort and 0.917 (95% CI=0.738-1.000) in the test cohort. The calibration curve indicated that the radiomics nomogram had considerable clinical usefulness in prediction, observation, and decision curve analysis. CONCLUSION A reliable and powerful tool for identifying osteoporosis can be provided by the nomogram that combines the T1W and T2W imaging radiomics score with clinical risk factors.
Collapse
Affiliation(s)
- Si-Ru Kang
- Department of Radiology, Xiaogan Hospital Affiliated to Wuhan University of Science and Technology, Xiaogan, PR China
| | - Kai Wang
- Department of Orthopedics, Xiaogan Hospital Affiliated to Wuhan University of Science and Technology, Xiaogan, PR China
| |
Collapse
|
10
|
Tong X, Wang S, Cheng Q, Fan Y, Fang X, Wei W, Li J, Liu Y, Liu L. Effect of fully automatic classification model from different tube voltage images on bone density screening: A self-controlled study. Eur J Radiol 2024; 177:111521. [PMID: 38850722 DOI: 10.1016/j.ejrad.2024.111521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 04/27/2024] [Accepted: 05/19/2024] [Indexed: 06/10/2024]
Abstract
PURPOSE To develop two bone status prediction models combining deep learning and radiomics based on standard-dose chest computed tomography (SDCT) and low-dose chest computed tomography (LDCT), and to evaluate the effect of tube voltage on reproducibility of radiomics features and predictive efficacy of these models. METHODS A total of 1508 patients were enrolled in this retrospective study. LDCT was conducted using 80 kVp, tube current ranging from 100 to 475 mA. On the other hand, SDCT was performed using 120 kVp, tube current ranging from 100 to 520 mA. We developed an automatic thoracic vertebral cancellous bone (TVCB) segmentation model. Subsequently, 1184 features were extracted and two classifiers were developed based on LDCT and SDCT images. Based on the diagnostic results of quantitative computed tomography examination, the first-level classifier was initially developed to distinguish normal or abnormal BMD (including osteoporosis and osteopenia), while the second-level classifier was employed to identify osteoporosis or osteopenia. The Dice coefficient was used to evaluate the performance of the automated segmentation model. The Concordance Correlation Coefficients (CCC) of radiomics features were calculated between LDCT and SDCT, and the performance of these models was evaluated. RESULTS Our automated segmentation model achieved a Dice coefficient of 0.98 ± 0.01 and 0.97 ± 0.02 in LDCT and SDCT, respectively. Alterations in tube voltage decreased the reproducibility of the extracted radiomic features, with 85.05 % of the radiomic features exhibiting low reproducibility (CCC < 0.75). The area under the curve (AUC) using LDCT-based and SDCT-based models was 0.97 ± 0.01 and 0.94 ± 0.02, respectively. Nonetheless, cross-validation with independent test sets of different tube voltage scans suggests that variations in tube voltage can impair the diagnostic efficacy of the model. Consequently, radiomics models are not universally applicable to images of varying tube voltages. In clinical settings, ensuring consistency between the tube voltage of the image used for model development and that of the acquired patient image is critical. CONCLUSIONS Automatic bone status prediction models, utilizing either LDCT or SDCT images, enable accurate assessment of bone status. Tube voltage impacts reproducibility of features and predictive efficacy of models. It is necessary to account for tube voltage variation during the image acquisition.
Collapse
Affiliation(s)
- Xiaoyu Tong
- Department of Radiology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Shigeng Wang
- Department of Radiology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Qiye Cheng
- Department of Radiology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yong Fan
- Department of Radiology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Xin Fang
- Department of Radiology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Wei Wei
- Department of Radiology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | | | - Yijun Liu
- Department of Radiology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Lei Liu
- Department of Urology, First Affiliated Hospital of Dalian Medical University, Dalian, China.
| |
Collapse
|
11
|
Jia Q, Zheng H, Lin J, Guo J, Fan S, Alimujiang A, Wang X, Fu L, Xie Z, Ma C, Wang J. Optimizing diagnosis and surgical decisions for chronic osteomyelitis through radiomics in the precision medicine era. Front Bioeng Biotechnol 2024; 12:1315398. [PMID: 38798953 PMCID: PMC11127625 DOI: 10.3389/fbioe.2024.1315398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 04/17/2024] [Indexed: 05/29/2024] Open
Abstract
Introduction: Chronic osteomyelitis is a complex clinical condition that is associated with a high recurrence rate. Traditional surgical interventions often face challenges in achieving a balance between thorough debridement and managing resultant bone defects. Radiomics is an emerging technique that extracts quantitative features from medical images to reveal pathological information imperceptible to the naked eye. This study aims to investigate the potential of radiomics in optimizing osteomyelitis diagnosis and surgical treatment. Methods: Magnetic resonance imaging (MRI) scans of 93 suspected osteomyelitis patients were analyzed. Radiomics features were extracted from the original lesion region of interest (ROI) and an expanded ROI delineated by enlarging the original by 5 mm. Feature selection was performed and support vector machine (SVM) models were developed using the two ROI datasets. To assess the diagnostic efficacy of the established models, we conducted receiver operating characteristic (ROC) curve analysis, employing histopathological results as the reference standard. The model's performance was evaluated by calculating the area under the curve (AUC), sensitivity, specificity, and accuracy. Discrepancies in the ROC between the two models were evaluated using the DeLong method. All statistical analyses were carried out using Python, and a significance threshold of p < 0.05 was employed to determine statistical significance. Results and Discussion: A total of 1,037 radiomics features were extracted from each ROI. The expanded ROI model achieved significantly higher accuracy (0.894 vs. 0.821), sensitivity (0.947 vs. 0.857), specificity (0.842 vs. 0.785) and AUC (0.920 vs. 0.859) than the original ROI model. Key discriminative features included shape metrics and wavelet-filtered texture features. Radiomics analysis of MRI exhibits promising clinical translational potential in enhancing the diagnosis of chronic osteomyelitis by accurately delineating lesions and identifying surgical margins. The inclusion of an expanded ROI that encompasses perilesional tissue significantly improves diagnostic performance compared to solely focusing on the lesions. This study provides clinicians with a more precise and effective tool for diagnosis and surgical decision-making, ultimately leading to improved outcomes in this patient population.
Collapse
Affiliation(s)
- Qiyu Jia
- The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | - Hao Zheng
- The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
| | - Jie Lin
- The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
| | - Jian Guo
- The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | - Sijia Fan
- The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
| | | | - Xi Wang
- The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | - Lanqi Fu
- The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
| | - Zengru Xie
- The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | - Chuang Ma
- The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | - Junna Wang
- The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
| |
Collapse
|
12
|
Wang J, Xue M, Hu Y, Li J, Li Z, Wang Y. Proteomic Insights into Osteoporosis: Unraveling Diagnostic Markers of and Therapeutic Targets for the Metabolic Bone Disease. Biomolecules 2024; 14:554. [PMID: 38785961 PMCID: PMC11118602 DOI: 10.3390/biom14050554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 04/25/2024] [Accepted: 05/01/2024] [Indexed: 05/25/2024] Open
Abstract
Osteoporosis (OP), a prevalent skeletal disorder characterized by compromised bone strength and increased susceptibility to fractures, poses a significant public health concern. This review aims to provide a comprehensive analysis of the current state of research in the field, focusing on the application of proteomic techniques to elucidate diagnostic markers and therapeutic targets for OP. The integration of cutting-edge proteomic technologies has enabled the identification and quantification of proteins associated with bone metabolism, leading to a deeper understanding of the molecular mechanisms underlying OP. In this review, we systematically examine recent advancements in proteomic studies related to OP, emphasizing the identification of potential biomarkers for OP diagnosis and the discovery of novel therapeutic targets. Additionally, we discuss the challenges and future directions in the field, highlighting the potential impact of proteomic research in transforming the landscape of OP diagnosis and treatment.
Collapse
Affiliation(s)
- Jihan Wang
- Xi’an Key Laboratory of Stem Cell and Regenerative Medicine, Institute of Medical Research, Northwestern Polytechnical University, Xi’an 710072, China; (J.W.)
| | - Mengju Xue
- School of Medicine, Xi’an International University, Xi’an 710077, China
| | - Ya Hu
- Department of Medical College, Hunan Polytechnic of Environment and Biology, Hengyang 421000, China
| | - Jingwen Li
- Xi’an Key Laboratory of Stem Cell and Regenerative Medicine, Institute of Medical Research, Northwestern Polytechnical University, Xi’an 710072, China; (J.W.)
- Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen 518057, China
| | - Zhenzhen Li
- Xi’an Key Laboratory of Stem Cell and Regenerative Medicine, Institute of Medical Research, Northwestern Polytechnical University, Xi’an 710072, China; (J.W.)
- Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen 518057, China
| | - Yangyang Wang
- School of Electronics and Information, Northwestern Polytechnical University, Xi’an 710129, China
| |
Collapse
|
13
|
Lai YH, Tsai YS, Su PF, Li CI, Chen HHW. A computed tomography radiomics-based model for predicting osteoporosis after breast cancer treatment. Phys Eng Sci Med 2024; 47:239-248. [PMID: 38190012 DOI: 10.1007/s13246-023-01360-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 11/21/2023] [Indexed: 01/09/2024]
Abstract
Many treatments against breast cancer decrease the level of estrogen in blood, resulting in bone loss, osteoporosis and fragility fractures in breast cancer patients. This retrospective study aimed to evaluate a novel opportunistic screening for cancer treatment-induced bone loss (CTIBL) in breast cancer patients using CT radiomics. Between 2011 and 2021, a total of 412 female breast cancer patients who received treatment and were followed up in our institution, had post-treatment dual-energy X-ray absorptiometry (DXA) examination of the lumbar vertebrae and had post-treatment chest CT scan that encompassed the L1 vertebra, were included in this study. Results indicated that the T-score of L1 vertebra had a strongly positive correlation with the average T-score of L1-L4 vertebrae derived from DXA (r = 0.91, p < 0.05). On multivariable analysis, four clinical variables (age, body weight, menopause status, aromatase inhibitor exposure duration) and three radiomic features extracted from the region of interest of L1 vertebra (original_firstorder_RootMeanSquared, wavelet.HH_glcm_InverseVariance, and wavelet.LL_glcm_MCC) were selected for building predictive models of L1 T-score and bone health. The predictive model combining clinical and radiomic features showed the greatest adjusted R2 value (0.557), sensitivity (83.6%), specificity (74.2%) and total accuracy (79.4%) compared to models that relied solely on clinical data, radiomic features, or Hounsfield units. In conclusion, the clinical-radiomic predictive model may be used as an opportunistic screening tool for early identification of breast cancer survivors at high risk of CTIBL based on non-contrast CT images of the L1 vertebra, thereby facilitating early intervention for osteoporosis.
Collapse
Affiliation(s)
- Yu-Hsuan Lai
- Institute of Clinical Medicine, College of Medicine, National Cheng Kung University, Tainan, Taiwan
- Department of Radiation Oncology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
- Department of Oncology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, No. 138 Sheng-Li Rd, Tainan, 704302, Taiwan
- Clinical Innovation and Research Center, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Yi-Shan Tsai
- Clinical Innovation and Research Center, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
- Department of Medical Imaging, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Pei-Fang Su
- Department of Statistics, National Cheng Kung University, Tainan, Taiwan
| | - Chung-I Li
- Department of Statistics, National Cheng Kung University, Tainan, Taiwan
| | - Helen H W Chen
- Institute of Clinical Medicine, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
- Department of Radiation Oncology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
- Department of Oncology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, No. 138 Sheng-Li Rd, Tainan, 704302, Taiwan.
| |
Collapse
|
14
|
Zhen T, Fang J, Hu D, Shen Q, Ruan M. Comparative evaluation of multiparametric lumbar MRI radiomic models for detecting osteoporosis. BMC Musculoskelet Disord 2024; 25:185. [PMID: 38424582 PMCID: PMC10902949 DOI: 10.1186/s12891-024-07309-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Accepted: 02/24/2024] [Indexed: 03/02/2024] Open
Abstract
BACKGROUND Osteoporosis is a serious global public health issue. Currently, there are few studies that explore the use of multiparametric MRI radiomics for osteoporosis detection. The purpose of this study was to compare the performance of radiomics features from multiple MRI sequences (T1WI, T2WI and T1WI combined with T2WI) for detecting osteoporosis in patients. METHODS A retrospective analysis was performed on 160 patients who had undergone dual-energy X-ray absorptiometry(DXA) and lumbar magnetic resonance imaging (MRI) at our hospital. Among them, 86 patients were diagnosed with abnormal bone mass (osteoporosis or low bone mass), and 74 patients were diagnosed with normal bone mass based on the DXA results. Sagittal T1-and T2-weighted images of all patients were imported into the uAI Research Portal (United Imaging Intelligence) for image delineation and radiomics analysis, where a series of radiomic features were obtained. A radiomic model that included T1WI, T2WI, and T1WI+T2WI was established using features selected by LASSO regression. We used ROC curve analysis to evaluate the predictive efficacy of each model for identifying bone abnormalities and conducted decision curve analysis (DCA) to evaluate the net benefit of each model. Finally, we validated the model in a sample of 35 patients from different health care institution. RESULTS The T1WI + T2WI radiomics model showed better screening performance for patients with abnormal bone mass. In the training group, the sensitivity was 0.758, the specificity was 0.78, and the accuracy was 0.768 (AUC =0.839, 95% CI=0.757-0.901). In the validation group, the sensitivity was 0.792, the specificity was 0.875, and the accuracy was 0.833 (AUC =0.86, 95% CI=0.73-0.943).The DCA also showed that the combined model had better net benefits. In the external validation group, the sensitivity was 0.764, the specificity was 0.833, and the accuracy was 0.8 (AUC =0.824, 95% CI 0.678-0.969). CONCLUSIONS Radiomics-based multiparametric MRI can be used for the quantitative analysis of lumbar MRI and for accurately screening patients with abnormal bone mass.
Collapse
Affiliation(s)
- Tao Zhen
- Department of Radiology, Hangzhou First People's Hospital, No.261, Huansha Road, Hangzhou, Zhejiang, 310006, China.
| | - Jing Fang
- Zhejiang Provincial Hospital of Traditional Chinese medicine, Hangzhou, 310006, China
| | - Dacheng Hu
- Department of Radiology, Hangzhou First People's Hospital, No.261, Huansha Road, Hangzhou, Zhejiang, 310006, China
| | - Qijun Shen
- Department of Radiology, Hangzhou First People's Hospital, No.261, Huansha Road, Hangzhou, Zhejiang, 310006, China
| | - Mei Ruan
- Department of Radiology, Hangzhou First People's Hospital, No.261, Huansha Road, Hangzhou, Zhejiang, 310006, China
| |
Collapse
|
15
|
Zhang B, Chen Z, Yan R, Lai B, Wu G, You J, Wu X, Duan J, Zhang S. Development and Validation of a Feature-Based Broad-Learning System for Opportunistic Osteoporosis Screening Using Lumbar Spine Radiographs. Acad Radiol 2024; 31:84-92. [PMID: 37495426 DOI: 10.1016/j.acra.2023.07.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 07/04/2023] [Accepted: 07/05/2023] [Indexed: 07/28/2023]
Abstract
RATIONALE AND OBJECTIVES Osteoporosis is primarily diagnosed using dual-energy X-ray absorptiometry (DXA); yet, DXA is significantly underutilized, causing osteoporosis, an underdiagnosed condition. We aimed to provide an opportunistic approach to screen for osteoporosis using artificial intelligence based on lumbar spine X-ray radiographs. MATERIALS AND METHODS In this institutional review board-approved retrospective study, female patients aged ≥50 years who received both X-ray scans and DXA of the lumbar vertebrae, in three centers, were included. A total of 1180 cases were used for training and 145 cases were used for testing. We proposed a novel broad-learning system (BLS) and then compared the performance of BLS models using radiomic features and deep features as a source of input. The deep features were extracted using ResNet18 and VGG11, respectively. The diagnostic performances of these BLS models were evaluated with the area under the curve (AUC), sensitivity, and specificity. RESULTS The incidence rate of osteoporosis in the training and test sets was 35.9% and 37.9%, respectively. The radiomic feature-based BLS model achieved higher testing AUC (0.802 vs. 0.654 vs. 0.632, both P = .002), sensitivity (78.2% vs. 56.4% vs. 50.9%), and specificity (82.2% vs. 74,4% vs. 75.6%) than the two deep feature-based BLS models. CONCLUSION Our proposed radiomic feature-based BLS model has the potential to expand osteoporosis screening to a broader population by identifying osteoporosis on lumbar spine X-ray radiographs.
Collapse
Affiliation(s)
- Bin Zhang
- Department of Radiology, The First Affiliated Hospital of Jinan University, No. 613 Huangpu West Road, Tianhe District, Guangzhou, Guangdong 510627, China (B.Z., R.Y., J.Y., X.W., S.Z.)
| | - Zhangtianyi Chen
- College of Information Science and Technology, Jinan University, Guangzhou, Guangdong, China (Z.C., B.L., G.W., J.D.)
| | - Ruike Yan
- Department of Radiology, The First Affiliated Hospital of Jinan University, No. 613 Huangpu West Road, Tianhe District, Guangzhou, Guangdong 510627, China (B.Z., R.Y., J.Y., X.W., S.Z.)
| | - Bifan Lai
- College of Information Science and Technology, Jinan University, Guangzhou, Guangdong, China (Z.C., B.L., G.W., J.D.)
| | - Guangheng Wu
- College of Information Science and Technology, Jinan University, Guangzhou, Guangdong, China (Z.C., B.L., G.W., J.D.)
| | - Jingjing You
- Department of Radiology, The First Affiliated Hospital of Jinan University, No. 613 Huangpu West Road, Tianhe District, Guangzhou, Guangdong 510627, China (B.Z., R.Y., J.Y., X.W., S.Z.)
| | - Xuewei Wu
- Department of Radiology, The First Affiliated Hospital of Jinan University, No. 613 Huangpu West Road, Tianhe District, Guangzhou, Guangdong 510627, China (B.Z., R.Y., J.Y., X.W., S.Z.)
| | - Junwei Duan
- College of Information Science and Technology, Jinan University, Guangzhou, Guangdong, China (Z.C., B.L., G.W., J.D.); Guangdong Provincial Key Laboratory of Traditional Chinese Medicine Informatization, Jinan University, Guangzhou, Guangdong, China (J.D.)
| | - Shuixing Zhang
- Department of Radiology, The First Affiliated Hospital of Jinan University, No. 613 Huangpu West Road, Tianhe District, Guangzhou, Guangdong 510627, China (B.Z., R.Y., J.Y., X.W., S.Z.).
| |
Collapse
|
16
|
Martel D, Monga A, Chang G. Radiomic analysis of the proximal femur in osteoporosis women using 3T MRI. FRONTIERS IN RADIOLOGY 2023; 3:1293865. [PMID: 38077634 PMCID: PMC10702560 DOI: 10.3389/fradi.2023.1293865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 11/06/2023] [Indexed: 02/12/2024]
Abstract
Introduction Osteoporosis (OP) results in weak bone and can ultimately lead to fracture. MRI assessment of bone structure and microarchitecture has been proposed as method to assess bone quality and fracture risk in vivo. Radiomics provides a framework to analyze the textural information of MR images. The purpose of this study was to analyze the radiomic features and its abilityto differentiate between subjects with and without prior fragility fracture. Methods MRI acquisition was performed on n = 45 female OP subjects: 15 with fracture history (Fx) and 30 without fracture history (nFx) using a high-resolution 3D Fast Low Angle Shot (FLASH) sequence at 3T. Second and first order radiomic features were calculated in the trabecular region of the proximal femur on T1-weighted MRI signal of a matched dataset. Significance of the feature's predictive ability was measured using Wilcoxon test and Area Under the ROC (AUROC) curve analysis. The features were correlated DXA and FRAX score. Result A set of three independent radiomic features (Dependence Non-Uniformity (DNU), Low Gray Level Emphasis (LGLE) and Kurtosis) showed significant ability to predict fragility fracture (AUROC DNU = 0.751, p < 0.05; AUROC LGLE = 0.729, p < 0.05; AUROC Kurtosis = 0.718, p < 0.05) with low to moderate correlation with FRAX and DXA. Conclusion Radiomic features can measure bone health in MRI of proximal femur and has the potential to predict fracture.
Collapse
Affiliation(s)
- Dimitri Martel
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
| | | | | |
Collapse
|
17
|
Jiang Y, Zhang W, Huang S, Huang Q, Ye H, Zeng Y, Hua X, Cai J, Liu Z, Liu Q. Preoperative Prediction of New Vertebral Fractures after Vertebral Augmentation with a Radiomics Nomogram. Diagnostics (Basel) 2023; 13:3459. [PMID: 37998595 PMCID: PMC10670105 DOI: 10.3390/diagnostics13223459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 11/11/2023] [Accepted: 11/14/2023] [Indexed: 11/25/2023] Open
Abstract
The occurrence of new vertebral fractures (NVFs) after vertebral augmentation (VA) procedures is common in patients with osteoporotic vertebral compression fractures (OVCFs), leading to painful experiences and financial burdens. We aim to develop a radiomics nomogram for the preoperative prediction of NVFs after VA. Data from center 1 (training set: n = 153; internal validation set: n = 66) and center 2 (external validation set: n = 44) were retrospectively collected. Radiomics features were extracted from MRI images and radiomics scores (radscores) were constructed for each level-specific vertebra based on least absolute shrinkage and selection operator (LASSO). The radiomics nomogram, integrating radiomics signature with presence of intravertebral cleft and number of previous vertebral fractures, was developed by multivariable logistic regression analysis. The predictive performance of the vertebrae was level-specific based on radscores and was generally superior to clinical variables. RadscoreL2 had the optimal discrimination (AUC ≥ 0.751). The nomogram provided good predictive performance (AUC ≥ 0.834), favorable calibration, and large clinical net benefits in each set. It was used successfully to categorize patients into high- or low-risk subgroups. As a noninvasive preoperative prediction tool, the MRI-based radiomics nomogram holds great promise for individualized prediction of NVFs following VA.
Collapse
Affiliation(s)
- Yang Jiang
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen 518000, China; (Y.J.); (W.Z.); (J.C.)
| | - Wei Zhang
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen 518000, China; (Y.J.); (W.Z.); (J.C.)
| | - Shihao Huang
- Department of Radiology, The Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai 519000, China;
| | - Qing Huang
- Department of Endocrinology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen 518000, China;
| | - Haoyi Ye
- Department of Radiology, The Fourth Affiliated Hospital, Guangzhou Medical University, Guangzhou 511300, China;
| | - Yurong Zeng
- Department of Radiology, Huizhou Central People’s Hospital, Huizhou 516000, China;
| | - Xin Hua
- Department of Neurology, The First Affiliated Hospital, Wenzhou Medical University, Wenzhou 325000, China;
| | - Jinhui Cai
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen 518000, China; (Y.J.); (W.Z.); (J.C.)
| | - Zhifeng Liu
- Department of Radiology, The Fourth Affiliated Hospital, Guangzhou Medical University, Guangzhou 511300, China;
| | - Qingyu Liu
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen 518000, China; (Y.J.); (W.Z.); (J.C.)
| |
Collapse
|
18
|
Cai J, Shen C, Yang T, Jiang Y, Ye H, Ruan Y, Zhu X, Liu Z, Liu Q. MRI-based radiomics assessment of the imminent new vertebral fracture after vertebral augmentation. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2023; 32:3892-3905. [PMID: 37624438 DOI: 10.1007/s00586-023-07887-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 07/13/2023] [Accepted: 08/06/2023] [Indexed: 08/26/2023]
Abstract
BACKGROUND Imminent new vertebral fracture (NVF) is highly prevalent after vertebral augmentation (VA). An accurate assessment of the imminent risk of NVF could help to develop prompt treatment strategies. PURPOSE To develop and validate predictive models that integrated the radiomic features and clinical risk factors based on machine learning algorithms to evaluate the imminent risk of NVF. MATERIALS AND METHODS In this retrospective study, a total of 168 patients with painful osteoporotic vertebral compression fractures treated with VA were evaluated. Radiomic features of L1 vertebrae based on lumbar T2-weighted images were obtained. Univariate and LASSO-regression analyses were applied to select the optimal features and construct radiomic signature. The radiomic signature and clinical signature were integrated to develop a predictive model by using machine learning algorithms including LR, RF, SVM, and XGBoost. Receiver operating characteristic curve and calibration curve analyses were used to evaluate the predictive performance of the models. RESULTS The radiomic-XGBoost model with the highest AUC of 0.93 of the training cohort and 0.9 of the test cohort among the machine learning algorithms. The combined-XGBoost model with the best performance with an AUC of 0.9 in the training cohort and 0.9 in the test cohort. The radiomic-XGBoost model and combined-XGBoost model achieved better performance to assess the imminent risk of NVF than that of the clinical risk factors alone (p < 0.05). CONCLUSION Radiomic and machine learning modeling based on T2W images of preoperative lumbar MRI had an excellent ability to evaluate the imminent risk of NVF after VA.
Collapse
Affiliation(s)
- Jinhui Cai
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-Sen University, 628 Zhenyuan Road, Xinhu Street, Guangming New District, Shenzhen, 518107, Guangdong, China
- Department of Radiology, The Fourth Affiliated Hospital of Guangzhou Medical University, 1 Guangming East Road, Zengjiang Street, Zengcheng District, Guangzhou, 511300, Guangdong, China
| | - Chen Shen
- Department of Radiology, The Fourth Affiliated Hospital of Guangzhou Medical University, 1 Guangming East Road, Zengjiang Street, Zengcheng District, Guangzhou, 511300, Guangdong, China
| | - Tingqian Yang
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-Sen University, 628 Zhenyuan Road, Xinhu Street, Guangming New District, Shenzhen, 518107, Guangdong, China
| | - Yang Jiang
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-Sen University, 628 Zhenyuan Road, Xinhu Street, Guangming New District, Shenzhen, 518107, Guangdong, China
| | - Haoyi Ye
- Department of Radiology, The Fourth Affiliated Hospital of Guangzhou Medical University, 1 Guangming East Road, Zengjiang Street, Zengcheng District, Guangzhou, 511300, Guangdong, China
| | - Yaoqin Ruan
- Department of Radiology, The Fourth Affiliated Hospital of Guangzhou Medical University, 1 Guangming East Road, Zengjiang Street, Zengcheng District, Guangzhou, 511300, Guangdong, China
| | - Xuemin Zhu
- Department of Spine Surgery, The Fourth Affiliated Hospital of Guangzhou Medical University, Guangzhou, 511300, China
| | - Zhifeng Liu
- Department of Radiology, The Fourth Affiliated Hospital of Guangzhou Medical University, 1 Guangming East Road, Zengjiang Street, Zengcheng District, Guangzhou, 511300, Guangdong, China.
| | - Qingyu Liu
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-Sen University, 628 Zhenyuan Road, Xinhu Street, Guangming New District, Shenzhen, 518107, Guangdong, China.
| |
Collapse
|
19
|
Fang K, Zheng X, Lin X, Dai Z. Unveiling Osteoporosis Through Radiomics Analysis of Hip CT Imaging. Acad Radiol 2023; 31:S1076-6332(23)00544-5. [PMID: 39492007 DOI: 10.1016/j.acra.2023.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 10/02/2023] [Accepted: 10/03/2023] [Indexed: 11/05/2024]
Abstract
RATIONALE AND OBJECTIVES This study aims to investigate the use of radiomics analysis of hip CT imaging to unveil osteoporosis. MATERIALS AND METHODS The researchers analyzed hip CT scans from a cohort of patients, including both osteoporotic and healthy individuals. Radiomics technique are employed to extract a comprehensive array of features from these images, encompassing texture, shape, and intensity alterations. Radiomics analysis using the 10 most commonly used machine learning models was employed to identify screened radiomics features for the detection of osteoporosis in patients. In addition to radiomics features, the basic information of patients is also utilized as training data for these machine learning models to accurately identify the presence of osteoporosis. A comparison would be made between the efficiency of recognizing radiomics features and the efficiency of recognizing patient basic information. The machine learning model that achieves the highest performance would be chosen to integrate patient basic information and radiomics features for the development of clinical nomograms. RESULT After a thorough screening process, 16 radiomics features were selected as input parameters for the machine learning model. In the test group, the highest accuracy achieved using radiomics features was 0.849, with an area under the curve (AUC) of 0.919. Evaluation of clinical features identified age and gender as closely associated with osteoporosis. Among these features, the KNN model exhibited the highest accuracy of 0.731 and an AUC of 0.658 in the test group. Comparing the performance of radiomics and clinical features, radiomics features demonstrated superior AUC values in the machine learning models. Ultimately, the XGBoost model, utilizing both radiomics and clinical features, was selected as the final Nomogram prediction model. In the test group, this model achieved an accuracy of 0.882 and an AUC of 0.886 in screening for osteoporosis. CONCLUSION Radiomics features derived from hip CT scans exhibit strong screening capabilities for osteoporosis. Furthermore, when combined with easily obtainable clinical features like patient age and gender, an effective screening efficacy for osteoporosis can be achieved.
Collapse
Affiliation(s)
- Kaibin Fang
- Department of Orthopaedic Surgery, The Second Affiliated Hospital of Fujian Medical University, No. 34, Zhongshanbeilu, Quanzhou, 362000, China (K.F., X.L., Z.D.)
| | - Xiaoling Zheng
- Liming Vocational University, Quanzhou, 362000, China (X.Z.)
| | - Xiaocong Lin
- Department of Orthopaedic Surgery, The Second Affiliated Hospital of Fujian Medical University, No. 34, Zhongshanbeilu, Quanzhou, 362000, China (K.F., X.L., Z.D.)
| | - Zhangsheng Dai
- Department of Orthopaedic Surgery, The Second Affiliated Hospital of Fujian Medical University, No. 34, Zhongshanbeilu, Quanzhou, 362000, China (K.F., X.L., Z.D.).
| |
Collapse
|
20
|
Liu XG, Chen X, Chen B, Liang PJ, Liu HH, Fu M. Vertebral bone quality different in magnetic resonance imaging parameters. J Orthop Surg Res 2023; 18:772. [PMID: 37828514 PMCID: PMC10571331 DOI: 10.1186/s13018-023-04268-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 10/06/2023] [Indexed: 10/14/2023] Open
Abstract
OBJECTIVE This was a single-center retrospective study that aimed to measure the vertebral bone quality (VBQ) in people of all ages and compare changes in VBQ across ages. Differences in VBQ under various MRI parameters were compared. METHODS We first screened patients without underlying disease and no history of fractures who underwent lumbar MRI in our center in the past four years. Over the span of 10 years, 200 patients (100 males and 100 females) were randomly recruited into each cohort to undergo 1.5 T and 3.0 T MRI scans. Subsequently, we tabulated the number of patients admitted to our hospital with OVCF over the past four years. There were 30 healthy adults under 4 times of MRI scans in different parameters to determine the differentiation of VBQ. The 30 healthy adults were recruited to validate the differentiation of VBQ under various parameters. RESULTS A total of 2400 patients without OVCF and 405 patients with OVCF were enrolled. The VBQ value of 1.5 T was significantly higher compared with that of 3.0 T (2.769 ± 0.494 > 2.199 ± 0.432, P < 0.0001). VBQ of 43.31 kHz in 1.5 T was significantly lower than that of 35.36 kHz (2.447 ± 0.350 < 2.632 ± 0.280, P < 0.05). The differentiation of VBQ in 1.5 T and 3.0 T was validated using results of healthy adults. CONCLUSIONS VBQ is an effective tool for differentiating patients with OVCF and can be used as a primary screening tool for osteoporosis. However, VBQ is significantly affected by magnetic field intensity and bandwidth and cannot achieve its universality as it originally proposed.
Collapse
Affiliation(s)
- Xiang-Ge Liu
- Department of Spinal Surgery, Foshan Fosun Chancheng Hospital, Fosun Group, Foshan, 528000, China
| | - Xin Chen
- Department of Spinal Surgery, Foshan Fosun Chancheng Hospital, Fosun Group, Foshan, 528000, China
| | - Biao Chen
- Department of Spinal Surgery, Foshan Fosun Chancheng Hospital, Fosun Group, Foshan, 528000, China
| | - Pei-Jie Liang
- Department of Spinal Surgery, Foshan Fosun Chancheng Hospital, Fosun Group, Foshan, 528000, China
| | - Han-Hui Liu
- Department of Spinal Surgery, Foshan Fosun Chancheng Hospital, Fosun Group, Foshan, 528000, China
| | - Meiqi Fu
- Department of Spinal Surgery, Foshan Fosun Chancheng Hospital, Fosun Group, Foshan, 528000, China.
| |
Collapse
|
21
|
Ullah KA, Rehman F, Anwar M, Faheem M, Riaz N. Machine learning-based prediction of osteoporosis in postmenopausal women with clinical examined features: A quantitative clinical study. Health Sci Rep 2023; 6:e1656. [PMID: 37900094 PMCID: PMC10600334 DOI: 10.1002/hsr2.1656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 09/30/2023] [Accepted: 10/11/2023] [Indexed: 10/31/2023] Open
Abstract
Osteoporosis is a skeletal disease that is commonly seen in older people but often neglected due to its silent nature. To overcome the issue of osteoporosis in men and women, we proposed an advanced prediction model with the help of machine learning techniques which can help to identify the potential occurrence of this bone disease by its advanced screening tools. To achieve more reliable and accurate results, various machine-learning techniques were applied to the presented data sets. Moreover, we also compared the performance of our results with other existing algorithms to solely focus on the advanced features of the proposed methodology. The two data sets, the clinical tests of patients in Taiwan and medical reports of postmenopausal women in Korea through Korean Health and Nutrition Examination Surveys (2010-2011) were considered in this study. To predict bone disorders, we utilized the data about females and developed a system using artificial neural networks, support vector machines, and K-nearest neighbor. To compare the performance of the model Area under the Receiver Operating Characteristic Curve and other evaluation metrics were compared. The achieved results from all the algorithms and compared them with Osteoporosis Self-Assessment Tool for Asians and the results were noticeably better and more reliable than existing systems due to the involvement of ML. Using machine learning techniques to predict these types of diseases is better because physicians and patients can take early action to prevent the consequences in advance.
Collapse
Affiliation(s)
- Kainat A. Ullah
- Department of Computer Science and Information TechnologyLahore Leads UniversityLahorePakistan
| | - Faisal Rehman
- Department of Computer Science and Information TechnologyLahore Leads UniversityLahorePakistan
- Department of Statistics and Data ScienceUniversity of MianwaliMianwaliPakistan
| | - Muhammad Anwar
- Department of Information Sciences, Division of Science and TechnologyUniversity of EducationLahorePakistan
| | - Muhammad Faheem
- School of Technology and InnovationsUniversity of VaasaVaasaFinland
| | - Naveed Riaz
- School of Electrical Engineering and Computer Science (SEECS)National University of Sciences & TechnologyIslamabadPakistan
| |
Collapse
|
22
|
Jiang Y, Cai J, Zeng Y, Ye H, Yang T, Liu Z, Liu Q. Development and validation of a machine learning model to predict imminent new vertebral fractures after vertebral augmentation. BMC Musculoskelet Disord 2023; 24:472. [PMID: 37296426 PMCID: PMC10251538 DOI: 10.1186/s12891-023-06557-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 05/19/2023] [Indexed: 06/12/2023] Open
Abstract
BACKGROUND Accurately predicting the occurrence of imminent new vertebral fractures (NVFs) in patients with osteoporotic vertebral compression fractures (OVCFs) undergoing vertebral augmentation (VA) is challenging with yet no effective approach. This study aim to examine a machine learning model based on radiomics signature and clinical factors in predicting imminent new vertebral fractures after vertebral augmentation. METHODS A total of 235 eligible patients with OVCFs who underwent VA procedures were recruited from two independent institutions and categorized into three groups, including training set (n = 138), internal validation set (n = 59), and external validation set (n = 38). In the training set, radiomics features were computationally retrieved from L1 or adjacent vertebral body (T12 or L2) on T1-w MRI images, and a radiomics signature was constructed using the least absolute shrinkage and selection operator algorithm (LASSO). Predictive radiomics signature and clinical factors were fitted into two final prediction models using the random survival forest (RSF) algorithm or COX proportional hazard (CPH) analysis. Independent internal and external validation sets were used to validate the prediction models. RESULTS The two prediction models were integrated with radiomics signature and intravertebral cleft (IVC). The RSF model with C-indices of 0.763, 0.773, and 0.731 and time-dependent AUC (2 years) of 0.855, 0.907, and 0.839 (p < 0.001 for all) was found to be better predictive than the CPH model in training, internal and external validation sets. The RSF model provided better calibration, larger net benefits (determined by decision curve analysis), and lower prediction error (time-dependent brier score of 0.156, 0.151, and 0.146, respectively) than the CPH model. CONCLUSIONS The integrated RSF model showed the potential to predict imminent NVFs following vertebral augmentation, which will aid in postoperative follow-up and treatment.
Collapse
Affiliation(s)
- Yang Jiang
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-Sen University, Shenzhen, China
| | - Jinhui Cai
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-Sen University, Shenzhen, China
| | - Yurong Zeng
- Department of Radiology, Huizhou Central People's Hospital, Huizhou, China
| | - Haoyi Ye
- Department of Radiology, The Fourth Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Tingqian Yang
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-Sen University, Shenzhen, China
| | - Zhifeng Liu
- Department of Radiology, The Fourth Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
| | - Qingyu Liu
- Department of Radiology, The Seventh Affiliated Hospital, Sun Yat-Sen University, Shenzhen, China.
| |
Collapse
|
23
|
Levi R, Garoli F, Battaglia M, Rizzo DAA, Mollura M, Savini G, Riva M, Tomei M, Ortolina A, Fornari M, Rohatgi S, Angelotti G, Savevski V, Mazziotti G, Barbieri R, Grimaldi M, Politi LS. CT-based radiomics can identify physiological modifications of bone structure related to subjects' age and sex. LA RADIOLOGIA MEDICA 2023:10.1007/s11547-023-01641-6. [PMID: 37147473 DOI: 10.1007/s11547-023-01641-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 04/26/2023] [Indexed: 05/07/2023]
Abstract
PURPOSE Radiomics of vertebral bone structure is a promising technique for identification of osteoporosis. We aimed at assessing the accuracy of machine learning in identifying physiological changes related to subjects' sex and age through analysis of radiomics features from CT images of lumbar vertebrae, and define its generalizability across different scanners. MATERIALS AND METHODS We annotated spherical volumes-of-interest (VOIs) in the center of the vertebral body for each lumbar vertebra in 233 subjects who had undergone lumbar CT for back pain on 3 different scanners, and we evaluated radiomics features from each VOI. Subjects with history of bone metabolism disorders, cancer, and vertebral fractures were excluded. We performed machine learning classification and regression models to identify subjects' sex and age respectively, and we computed a voting model which combined predictions. RESULTS The model was trained on 173 subjects and tested on an internal validation dataset of 60. Radiomics was able to identify subjects' sex within single CT scanner (ROC AUC: up to 0.9714), with lower performance on the combined dataset of the 3 scanners (ROC AUC: 0.5545). Higher consistency among different scanners was found in identification of subjects' age (R2 0.568 on all scanners, MAD 7.232 years), with highest results on a single CT scanner (R2 0.667, MAD 3.296 years). CONCLUSION Radiomics features are able to extract biometric data from lumbar trabecular bone, and determine bone modifications related to subjects' sex and age with great accuracy. However, acquisition from different CT scanners reduces the accuracy of the analysis.
Collapse
Affiliation(s)
- Riccardo Levi
- Department of Biomedical Sciences, Humanitas University, Via R. Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- Department of Neuroradiology, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Federico Garoli
- Department of Biomedical Sciences, Humanitas University, Via R. Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- Department of Neuroradiology, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Massimiliano Battaglia
- Department of Biomedical Sciences, Humanitas University, Via R. Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- Department of Neuroradiology, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Dario A A Rizzo
- Department of Biomedical Sciences, Humanitas University, Via R. Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- Department of Neuroradiology, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Maximilliano Mollura
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, 20133, Milan, Italy
| | - Giovanni Savini
- Department of Neuroradiology, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Marco Riva
- Department of Biomedical Sciences, Humanitas University, Via R. Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- Department of Neurosurgery, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Massimo Tomei
- Department of Neurosurgery, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Alessandro Ortolina
- Department of Neurosurgery, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Maurizio Fornari
- Department of Neurosurgery, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Saurabh Rohatgi
- Department of Neuroradiology, Massachusetts General Hospital, Boston, MA, 02114, USA
| | - Giovanni Angelotti
- Artificial Intelligence Center, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Victor Savevski
- Artificial Intelligence Center, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Gherardo Mazziotti
- Department of Biomedical Sciences, Humanitas University, Via R. Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
- Metabolic Bone Diseases and Osteoporosis Section, Endocrinology, Diabetology and Medical Andrology Unit, IRCCS, Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Riccardo Barbieri
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, 20133, Milan, Italy
| | - Marco Grimaldi
- Department of Neuroradiology, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy
| | - Letterio S Politi
- Department of Biomedical Sciences, Humanitas University, Via R. Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy.
- Department of Neuroradiology, IRCCS Humanitas Research Hospital, 20090, Rozzano, Italy.
| |
Collapse
|
24
|
Martín-Noguerol T, Oñate Miranda M, Amrhein TJ, Paulano-Godino F, Xiberta P, Vilanova JC, Luna A. The role of Artificial intelligence in the assessment of the spine and spinal cord. Eur J Radiol 2023; 161:110726. [PMID: 36758280 DOI: 10.1016/j.ejrad.2023.110726] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 01/13/2023] [Accepted: 01/31/2023] [Indexed: 02/05/2023]
Abstract
Artificial intelligence (AI) application development is underway in all areas of radiology where many promising tools are focused on the spine and spinal cord. In the past decade, multiple spine AI algorithms have been created based on radiographs, computed tomography, and magnetic resonance imaging. These algorithms have wide-ranging purposes including automatic labeling of vertebral levels, automated description of disc degenerative changes, detection and classification of spine trauma, identification of osseous lesions, and the assessment of cord pathology. The overarching goals for these algorithms include improved patient throughput, reducing radiologist workload burden, and improving diagnostic accuracy. There are several pre-requisite tasks required in order to achieve these goals, such as automatic image segmentation, facilitating image acquisition and postprocessing. In this narrative review, we discuss some of the important imaging AI solutions that have been developed for the assessment of the spine and spinal cord. We focus on their practical applications and briefly discuss some key requirements for the successful integration of these tools into practice. The potential impact of AI in the imaging assessment of the spine and cord is vast and promises to provide broad reaching improvements for clinicians, radiologists, and patients alike.
Collapse
Affiliation(s)
| | - Marta Oñate Miranda
- Department of Radiology, Centre Hospitalier Universitaire de Sherbrooke, Sherbrooke, Quebec, Canada.
| | - Timothy J Amrhein
- Department of Radiology, Duke University Medical Center, Durham, USA.
| | | | - Pau Xiberta
- Graphics and Imaging Laboratory (GILAB), University of Girona, 17003 Girona, Spain.
| | - Joan C Vilanova
- Department of Radiology. Clinica Girona, Diagnostic Imaging Institute (IDI), University of Girona, 17002 Girona, Spain.
| | - Antonio Luna
- MRI unit, Radiology department. HT medica, Carmelo Torres n°2, 23007 Jaén, Spain.
| |
Collapse
|
25
|
Wang J, Zhou S, Chen S, He Y, Gao H, Yan L, Hu X, Li P, Shen H, Luo M, You T, Li J, Zhong Z, Zhang K. Prediction of osteoporosis using radiomics analysis derived from single source dual energy CT. BMC Musculoskelet Disord 2023; 24:100. [PMID: 36750927 PMCID: PMC9903590 DOI: 10.1186/s12891-022-06096-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Accepted: 12/15/2022] [Indexed: 02/09/2023] Open
Abstract
BACKGROUND With the aging population of society, the incidence rate of osteoporosis is increasing year by year. Early diagnosis of osteoporosis plays a significant role in the progress of disease prevention. As newly developed technology, computed tomography (CT) radiomics could discover radiomic features difficult to recognize visually, providing convenient, comprehensive and accurate osteoporosis diagnosis. This study aimed to develop and validate a clinical-radiomics model based on the monochromatic imaging of single source dual-energy CT for osteoporosis prediction. METHODS One hundred sixty-four participants who underwent both single source dual-energy CT and quantitative computed tomography (QCT) lumbar-spine examination were enrolled in a study cohort including training datasets (n = 114 [30 osteoporosis and 84 non-osteoporosis]) and validation datasets (n = 50 [12 osteoporosis and 38 non-osteoporosis]). One hundred seven radiomics features were extracted from 70-keV monochromatic CT images. With QCT as the reference standard, a radiomics signature was built by using least absolute shrinkage and selection operator (LASSO) regression on the basis of reproducible features. A clinical-radiomics model was constructed by incorporating the radiomics signature and a significant clinical predictor (age) using multivariate logistic regression analysis. Model performance was assessed by its calibration, discrimination and clinical usefulness. RESULTS The radiomics signature comprised 14 selected features and showed good calibration and discrimination in both training and validation cohorts. The clinical-radiomics model, which incorporated the radiomics signature and a significant clinical predictor (age), also showed good discrimination, with an area under the receiver operating characteristic curve (AUC) of 0.938 (95% confidence interval, 0.903-0.952) in the training cohort and an AUC of 0.988 (95% confidence interval, 0.967-0.998) in the validation cohort, and good calibration. The clinical-radiomics model stratified participants into groups with osteoporosis and non-osteoporosis with an accuracy of 94.0% in the validation cohort. Decision curve analysis (DCA) demonstrated that the radiomics signature and the clinical-radiomics model were clinically useful. CONCLUSIONS The clinical-radiomics model incorporating the radiomics signature and a clinical parameter had a good ability to predict osteoporosis based on dual-energy CT monoenergetic imaging.
Collapse
Affiliation(s)
- Jinling Wang
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China ,grid.488482.a0000 0004 1765 5169College of Integrated Traditional Chinese and Western Medicine, Hunan University of Chinese Medicine, 300 Xueshi Road, Yuelu District, Changsha, 410208 People’s Republic of China
| | - Shuwei Zhou
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China ,grid.488482.a0000 0004 1765 5169College of Integrated Traditional Chinese and Western Medicine, Hunan University of Chinese Medicine, 300 Xueshi Road, Yuelu District, Changsha, 410208 People’s Republic of China
| | - Suping Chen
- GE Healthcare (Shanghai) Co., Ltd., Shanghai, 201203 People’s Republic of China
| | - Yewen He
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Hui Gao
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Luyou Yan
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Xiaoli Hu
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Ping Li
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Hongrong Shen
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Muqing Luo
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Tian You
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Jianyu Li
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Zeya Zhong
- grid.488482.a0000 0004 1765 5169Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007 People’s Republic of China
| | - Kun Zhang
- Department of Radiology, The First Hospital of Hunan University of Chinese Medicine, 95 Shaoshan Middle Road, Yuhua District, Changsha, 410007, People's Republic of China. .,College of Integrated Traditional Chinese and Western Medicine, Hunan University of Chinese Medicine, 300 Xueshi Road, Yuelu District, Changsha, 410208, People's Republic of China.
| |
Collapse
|
26
|
Xie Q, Chen Y, Hu Y, Zeng F, Wang P, Xu L, Wu J, Li J, Zhu J, Xiang M, Zeng F. Development and validation of a machine learning-derived radiomics model for diagnosis of osteoporosis and osteopenia using quantitative computed tomography. BMC Med Imaging 2022; 22:140. [PMID: 35941568 PMCID: PMC9358842 DOI: 10.1186/s12880-022-00868-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 07/26/2022] [Indexed: 12/01/2022] Open
Abstract
Background To develop and validate a quantitative computed tomography (QCT) based radiomics model for discriminating osteoporosis and osteopenia.
Methods A total of 635 patients underwent QCT were retrospectively included from November 2016 to November 2019. The patients with osteopenia or osteoporosis (N = 590) were divided into a training cohort (N = 414) and a test cohort (N = 176). Radiomics features were extracted from the QCT images of the third lumbar vertebra. Minimum redundancy and maximum relevance and least absolute shrinkage and selection operator were used for data dimensional reduction, features selection and radiomics model building. Multivariable logistic regression was applied to construct the combined clinical-radiomic model that incorporated radiomics signatures and clinical characteristics. The performance of the combined clinical-radiomic model was evaluated by the area under the curve of receiver operator characteristic curve (ROC–AUC), accuracy, specificity, sensitivity, positive predictive value, and negative predictive value. Results The patients with osteopenia or osteoporosis were randomly divided into training and test cohort with a ratio of 7:3. Six more predictive radiomics signatures, age, alkaline phosphatase and homocysteine were selected to construct the combined clinical-radiomic model for diagnosis of osteoporosis and osteopenia. The AUC of the combined clinical-radiomic model was 0.96 (95% confidence interval (CI), 0.95 to 0.98) in the training cohort and 0.96 (95% CI 0.92 to 1.00) in the test cohort, which were superior to the clinical model alone (training-AUC = 0.81, test-AUC = 0.79). The calibration curve demonstrated that the radiomics nomogram had good agreement between prediction and observation and decision curve analysis confirmed clinically useful. Conclusions The combined clinical-radiomic model that incorporates the radiomics score and clinical risk factors, can serve as a reliable and powerful tool for discriminating osteoporosis and osteopenia. Supplementary Information The online version contains supplementary material available at 10.1186/s12880-022-00868-5.
Collapse
Affiliation(s)
- Qianrong Xie
- Department of Clinical Research Center, Dazhou Central Hospital, No.56 Nanyuemiao Street, Tongchuan District, Dazhou, 635000, Sichuan, China.,Department of Laboratory Medicine, The Third People's Hospital of Chengdu, Chengdu, 610000, China
| | - Yue Chen
- Department of Clinical Medicine, Chengdu University of Traditional Chinese Medicine, No. 37 Shi-er-qiao Road, Jinniu District, Chengdu, 610000, Sichuan, China
| | - Yimei Hu
- Department of Orthopedics, Hospital of Chengdu University of Traditional Chinese Medicine, Chengdu, 610000, China
| | - Fanwei Zeng
- Department of Clinical Research Center, Dazhou Central Hospital, No.56 Nanyuemiao Street, Tongchuan District, Dazhou, 635000, Sichuan, China
| | - Pingxi Wang
- Department of Bone Disease, Dazhou Central Hospital, Dazhou, 635000, China
| | - Lin Xu
- Department of Medical Imaging, Dazhou Central Hospital, Dazhou, 635000, China
| | - Jianhong Wu
- Department of Bone Disease, Dazhou Central Hospital, Dazhou, 635000, China
| | - Jie Li
- Department of Clinical Research Center, Dazhou Central Hospital, No.56 Nanyuemiao Street, Tongchuan District, Dazhou, 635000, Sichuan, China
| | - Jing Zhu
- Department of Rheumatology and Immunology, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, No.32 First Ring Road West, Jinniu District, Chengdu, 610000, Sichuan, China.
| | - Ming Xiang
- Department of Clinical Medicine, Chengdu University of Traditional Chinese Medicine, No. 37 Shi-er-qiao Road, Jinniu District, Chengdu, 610000, Sichuan, China. .,Department of Orthopedics, Sichuan Provincial Orthopedic Hospital, Chengdu, 610000, China.
| | - Fanxin Zeng
- Department of Clinical Research Center, Dazhou Central Hospital, No.56 Nanyuemiao Street, Tongchuan District, Dazhou, 635000, Sichuan, China. .,Department of Clinical Medicine, Chengdu University of Traditional Chinese Medicine, No. 37 Shi-er-qiao Road, Jinniu District, Chengdu, 610000, Sichuan, China.
| |
Collapse
|
27
|
Affiliation(s)
- Paolo Spinnato
- Diagnostic and Interventional Radiology, IRCCS Istituto Ortopedico Rizzoli, Bologna (Italy)
| |
Collapse
|
28
|
Xue Z, Huo J, Sun X, Sun X, Ai ST, LichiZhang, Liu C. Using radiomic features of lumbar spine CT images to differentiate osteoporosis from normal bone density. BMC Musculoskelet Disord 2022; 23:336. [PMID: 35395769 PMCID: PMC8991484 DOI: 10.1186/s12891-022-05309-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 03/28/2022] [Indexed: 01/04/2023] Open
Abstract
OBJECTIVE This study aimed to develop a predictive model to detect osteoporosis using radiomic features from lumbar spine computed tomography (CT) images. METHODS A total of 133 patients were included in this retrospective study, 41 men and 92 women, with a mean age of 65.45 ± 9.82 years (range: 31-94 years); 53 had normal bone mineral density, 32 osteopenia, and 48 osteoporosis. For each patient, the L1-L4 vertebrae on the CT images were automatically segmented using SenseCare and defined as regions of interest (ROIs). In total, 1,197 radiomic features were extracted from these ROIs using PyRadiomics. The most significant features were selected using logistic regression and Pearson correlation coefficient matrices. Using these features, we constructed three linear classification models based on the random forest (RF), support vector machine (SVM), and K-nearest neighbor (KNN) algorithms, respectively. The training and test sets were repeatedly selected using fivefold cross-validation. The model performance was evaluated using the area under the receiver operator characteristic curve (AUC) and confusion matrix. RESULTS The classification model based on RF had the highest performance, with an AUC of 0.994 (95% confidence interval [CI]: 0.979-1.00) for differentiating normal BMD and osteoporosis, 0.866 (95% CI: 0.779-0.954) for osteopenia versus osteoporosis, and 0.940 (95% CI: 0.891-0.989) for normal BMD versus osteopenia. CONCLUSIONS The excellent performance of this radiomic model indicates that lumbar spine CT images can effectively be used to identify osteoporosis and as a tool for opportunistic osteoporosis screening.
Collapse
Affiliation(s)
- Zhihao Xue
- Institute for Medical Imaging Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jiayu Huo
- Institute for Medical Imaging Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Xiaojiang Sun
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xuzhou Sun
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Song Tao Ai
- Department of Radiology, Shanghai Ninth People's Hospital, Tong University Shanghai Jiao School of Medicine, Shanghai, China
| | - LichiZhang
- Institute for Medical Imaging Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| | - Chenglei Liu
- Department of Radiology, Shanghai Ninth People's Hospital, Tong University Shanghai Jiao School of Medicine, Shanghai, China.
| |
Collapse
|
29
|
Yang H, Yan S, Li J, Zheng X, Yao Q, Duan S, Zhu J, Li C, Qin J. Prediction of acute versus chronic osteoporotic vertebral fracture using radiomics-clinical model on CT. Eur J Radiol 2022; 149:110197. [DOI: 10.1016/j.ejrad.2022.110197] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 12/26/2021] [Accepted: 01/31/2022] [Indexed: 11/28/2022]
|
30
|
Jiang YW, Xu XJ, Wang R, Chen CM. Radiomics analysis based on lumbar spine CT to detect osteoporosis. Eur Radiol 2022; 32:8019-8026. [PMID: 35499565 PMCID: PMC9059457 DOI: 10.1007/s00330-022-08805-4] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 03/23/2022] [Accepted: 04/05/2022] [Indexed: 01/03/2023]
Abstract
OBJECTIVES Undiagnosed osteoporosis may lead to severe complications after spinal surgery. This study aimed to construct and validate a radiomic signature based on CT scans to screen for lumbar spine osteoporosis. METHODS Using a stratified random sample method, 386 vertebral bodies were randomly divided into a training set (n = 270) and a test set (n = 116). A total of 1040 radiomics features were automatically retracted from lumbar spine CT scans using the 3D slicer pyradiomics module, and a radiomic signature was created. The sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve (AUC) of the Hounsfield and radiomics signature models were calculated. The AUCs of the two models were compared using the DeLong test. Their clinical usefulness was assessed using a decision curve analysis. RESULTS Twelve features were chosen to establish the radiomic signature. The AUCs of the radiomics signature and Hounsfield models were 0.96 and 0.88 in the training set and 0.92 and 0.84 in the test set, respectively. According to the DeLong test, the AUCs of the two models were significantly different (p < 0.05). The radiomics signature model indicated a higher overall net benefit than the Hounsfield model, as determined by decision curve analysis. CONCLUSIONS The CT-based radiomic signature can differentiate patients with/without osteoporosis prior to lumbar spinal surgery. Without additional medical cost and radiation exposure, the radiomics method may provide valuable information facilitating surgical decision-making. KEY POINTS • The goal of the study was to evaluate the efficacy of a radiomics signature model based on routine preoperative lumbar spine CT scans in screening osteoporosis. • The radiomics signature model demonstrated excellent prediction performance in both the training and test sets. • This radiomics method may provide valuable information and facilitate surgical decision-making without additional medical costs and radiation exposure.
Collapse
Affiliation(s)
- Yan-Wei Jiang
- Department of Neurosurgery, Fujian Medical University Union Hospital, No. 29, Xin Quan Road, Fuzhou City, 350001, Fujian Province, China
| | - Xiong-Jie Xu
- Department of Neurosurgery, Fujian Medical University Union Hospital, No. 29, Xin Quan Road, Fuzhou City, 350001, Fujian Province, China
| | - Rui Wang
- Department of Neurosurgery, Fujian Medical University Union Hospital, No. 29, Xin Quan Road, Fuzhou City, 350001, Fujian Province, China
| | - Chun-Mei Chen
- Department of Neurosurgery, Fujian Medical University Union Hospital, No. 29, Xin Quan Road, Fuzhou City, 350001, Fujian Province, China.
| |
Collapse
|
31
|
Dai H, Wang Y, Fu R, Ye S, He X, Luo S, Jin W. Radiomics and stacking regression model for measuring bone mineral density using abdominal computed tomography. Acta Radiol 2021; 64:228-236. [PMID: 34964365 DOI: 10.1177/02841851211068149] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Measurement of bone mineral density (BMD) is the most important method to diagnose osteoporosis. However, current BMD measurement is always performed after a fracture has occurred. PURPOSE To explore whether a radiomic model based on abdominal computed tomography (CT) can predict the BMD of lumbar vertebrae. MATERIAL AND METHODS A total of 245 patients who underwent both dual-energy X-ray absorptiometry (DXA) and abdominal CT examination (training cohort, n = 196; validation cohort, n = 49) were included in our retrospective study. In total, 1218 image features were extracted from abdominal CT images for each patient. Combined with clinical information, three steps including least absolute shrinkage and selection operator (LASSO) regression were used to select key features. A two-tier stacking regression model with multi-algorithm fusion was used for BMD prediction, which can integrate the advantages of linear model and non-linear model. The prediction results of this model were compared with those using a single regressor. The degree-of-freedom adjusted coefficient of determination (Adjusted-R2), root mean square error (RMSE), and mean absolute error (MAE) were used to evaluate the regression performance. RESULTS Compared with other regression methods, the two-tier stacking regression model has a higher regression performance, with Adjusted-R2, RMSE, and MAE of 0.830, 0.077, and 0.06, respectively. Pearson correlation analysis and Bland-Altman analysis showed that the BMD predicted by the model had a high correlation with the DXA results (r = 0.932, difference = -0.01 ± 0.1412 mg/cm2). CONCLUSION Using radiomics, the BMD of lumbar vertebrae could be predicted from abdominal CT images.
Collapse
Affiliation(s)
- Hong Dai
- Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, Zhejiang, PR China
| | - Yutao Wang
- Department of Medical imaging, The Affiliated Hospital of Medical School, Ningbo University, Ningbo, Zhejiang, PR China
| | - Randi Fu
- Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, Zhejiang, PR China
| | - Sijia Ye
- Department of Medical imaging, The Affiliated Hospital of Medical School, Ningbo University, Ningbo, Zhejiang, PR China
| | - Xiuchao He
- Department of Medical imaging, The Affiliated Hospital of Medical School, Ningbo University, Ningbo, Zhejiang, PR China
| | - Shuying Luo
- Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, Zhejiang, PR China
| | - Wei Jin
- Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, Zhejiang, PR China
| |
Collapse
|
32
|
Somma T, DE Rosa A, Mastantuoni C, Esposito F, Meglio V, Romano F, Ricciardi L, DE Divitiis O, DI Somma C. Multidisciplinary management of osteoporotic vertebral fractures. An overview. Minerva Endocrinol (Torino) 2021; 47:189-202. [PMID: 34881854 DOI: 10.23736/s2724-6507.21.03515-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Vertebral fractures represent the most frequent complication associated with osteoporosis. Patients harboring a vertebral fracture complain physical impairment including low back pain and spine balance alteration, i.e., kyphosis, leading to subsequent systemic complication, with an increase in morbidity and mortality risk. Different strategies are available in the management of osteoporotic vertebral fractures: medical therapy acts as a prevention strategy while surgical vertebral augmentation procedures, when correctly indicated, aim to reduce pain and to restore the physiological vertebral height. Considering the growing prevalence and incidence of this condition and its socio-economic burden, prevention, diagnosis and treatment of osteoporotic vertebral fractures are of utmost importance. Our aim is to review the current strategies for the management of osteoporotic vertebral fractures providing an integrated multidisciplinary endocrinological, radiological and neurosurgical point of view.
Collapse
Affiliation(s)
- Teresa Somma
- Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Università degli Studi di Napoli Federico II, Naples, Italy
| | - Andrea DE Rosa
- Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Università degli Studi di Napoli Federico II, Naples, Italy -
| | - Ciro Mastantuoni
- Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Università degli Studi di Napoli Federico II, Naples, Italy
| | - Felice Esposito
- Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Università degli Studi di Napoli Federico II, Naples, Italy
| | - Vincenzo Meglio
- Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Università degli Studi di Napoli Federico II, Naples, Italy
| | - Fiammetta Romano
- Unit of Endocrinology, Department of Clinical Medicine and Surgery, Federico II University Medical School, Naples, Italy
| | - Luca Ricciardi
- Neurosurgery, Department NESMOS, Sapienza University of Rome, Rome, Italy
| | - Oreste DE Divitiis
- Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Università degli Studi di Napoli Federico II, Naples, Italy
| | - Carolina DI Somma
- Unit of Endocrinology, Department of Clinical Medicine and Surgery, Federico II University Medical School, Naples, Italy
| |
Collapse
|
33
|
Guiot J, Vaidyanathan A, Deprez L, Zerka F, Danthine D, Frix AN, Lambin P, Bottari F, Tsoutzidis N, Miraglio B, Walsh S, Vos W, Hustinx R, Ferreira M, Lovinfosse P, Leijenaar RTH. A review in radiomics: Making personalized medicine a reality via routine imaging. Med Res Rev 2021; 42:426-440. [PMID: 34309893 DOI: 10.1002/med.21846] [Citation(s) in RCA: 128] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 07/05/2021] [Accepted: 07/07/2021] [Indexed: 12/14/2022]
Abstract
Radiomics is the quantitative analysis of standard-of-care medical imaging; the information obtained can be applied within clinical decision support systems to create diagnostic, prognostic, and/or predictive models. Radiomics analysis can be performed by extracting hand-crafted radiomics features or via deep learning algorithms. Radiomics has evolved tremendously in the last decade, becoming a bridge between imaging and precision medicine. Radiomics exploits sophisticated image analysis tools coupled with statistical elaboration to extract the wealth of information hidden inside medical images, such as computed tomography (CT), magnetic resonance (MR), and/or Positron emission tomography (PET) scans, routinely performed in the everyday clinical practice. Many efforts have been devoted in recent years to the standardization and validation of radiomics approaches, to demonstrate their usefulness and robustness beyond any reasonable doubts. However, the booming of publications and commercial applications of radiomics approaches warrant caution and proper understanding of all the factors involved to avoid "scientific pollution" and overly enthusiastic claims by researchers and clinicians alike. For these reasons the present review aims to be a guidebook of sorts, describing the process of radiomics, its pitfalls, challenges, and opportunities, along with its ability to improve clinical decision-making, from oncology and respiratory medicine to pharmacological and genotyping studies.
Collapse
Affiliation(s)
- Julien Guiot
- Department of Pneumology, University Hospital of Liège, Liège, Belgium
| | - Akshayaa Vaidyanathan
- Radiomics (Oncoradiomics SA), Liège, Belgium.,The D-Lab, Department of Precision Medicine, Department of Nuclear Medicine, GROW-School for Oncology, Maastricht University, Maastricht, The Netherlands
| | - Louis Deprez
- Department of Radiology, University Hospital of Liège, Liège, Belgium
| | - Fadila Zerka
- Radiomics (Oncoradiomics SA), Liège, Belgium.,The D-Lab, Department of Precision Medicine, Department of Nuclear Medicine, GROW-School for Oncology, Maastricht University, Maastricht, The Netherlands
| | - Denis Danthine
- Department of Radiology, University Hospital of Liège, Liège, Belgium
| | - Anne-Noelle Frix
- Department of Pneumology, University Hospital of Liège, Liège, Belgium
| | - Philippe Lambin
- The D-Lab, Department of Precision Medicine, Department of Nuclear Medicine, GROW-School for Oncology, Maastricht University, Maastricht, The Netherlands
| | | | | | | | - Sean Walsh
- Radiomics (Oncoradiomics SA), Liège, Belgium
| | - Wim Vos
- Radiomics (Oncoradiomics SA), Liège, Belgium
| | - Roland Hustinx
- Department of Nuclear Medicine and Oncological Imaging, University Hospital of Liege, Liege, Belgium.,GIGA-CRC in vivo imaging, University of Liège, Liège, Belgium
| | - Marta Ferreira
- GIGA-CRC in vivo imaging, University of Liège, Liège, Belgium
| | - Pierre Lovinfosse
- Department of Nuclear Medicine and Oncological Imaging, University Hospital of Liege, Liege, Belgium
| | | |
Collapse
|
34
|
Wang G, Ma C. Application and prospect of radiomics in spinal cord and spine system diseases: A narrative review. GLIOMA 2021. [DOI: 10.4103/glioma.glioma_14_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|