1
|
Zhang J, Ren K, Qiu J, Chen B, Duan W, Liu J, Li G, Li D. Nanotexture and crystal phase regulation for synergistic enhancement in re-endothelialization on medical pure titanium surface. Mater Today Bio 2024; 25:100968. [PMID: 38312801 PMCID: PMC10835003 DOI: 10.1016/j.mtbio.2024.100968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 01/13/2024] [Accepted: 01/19/2024] [Indexed: 02/06/2024] Open
Abstract
Re-endothelialization has been recognized as a promising strategy to address the tissue hyperplasia and subsequent restenosis which are major complications associated with vascular implant/interventional titanium devices. However, the uncontrollable over-proliferation of smooth muscle cells (SMCs) limits the clinical application of numerous modified strategies. Herein, a novel modified strategy involving with a two-step anodic oxidation and annealing treatment was proposed to achieve rapid re-endothelialization function regulated by regular honeycomb nanotexture and specific anatase phase on the titanium surface. Theoretical calculation revealed that the presence of nanotexture reduced the polar component of surface energy, while the generation of anatase significantly enhanced the polar component and total surface energy. Meanwhile, the modified surface with regular nanotexture and anatase phase produced positive effect on the expression of CD31, VE-Cadherin and down-regulated α-SMA proteins expression, indicating excellent capacity of pro-endothelial regeneration and inhibition of SMCs proliferation and migration. One-month in vivo implantation in rabbit carotid arteries further confirmed that modified tube implant surface effectively accelerated confluent endothelial monolayer formation and promoted native-like endothelium tissue regeneration. By contrast, original titanium tube implant induced a disorganized tissue proliferation in the lumen with a high risk of restenosis. Collectively, this study opens us an alternative route to achieve the function that selectively promotes endothelial cells (ECs) growth and suppresses SMCs on the medical titanium surface, which has a great potential in facilitating re-endothelialization on the surface of blood-contacting titanium implant.
Collapse
Affiliation(s)
- Jing Zhang
- Advanced Medical Research Institute, Meili Lake Translational Research Park, Cheeloo College of Medicine, Shenzhen Research Institute of Shandong University, Shandong University, Jinan, Shandong, PR China
| | - Kai Ren
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, Shaanxi, PR China
| | - Jingru Qiu
- Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (Ministry of Education), School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, PR China
| | - Baolan Chen
- Advanced Medical Research Institute, Meili Lake Translational Research Park, Cheeloo College of Medicine, Shenzhen Research Institute of Shandong University, Shandong University, Jinan, Shandong, PR China
| | - Weixun Duan
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, Shaanxi, PR China
| | - Jincheng Liu
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, Shaanxi, PR China
| | - Guiling Li
- Advanced Medical Research Institute, Meili Lake Translational Research Park, Cheeloo College of Medicine, Shenzhen Research Institute of Shandong University, Shandong University, Jinan, Shandong, PR China
| | - Donghai Li
- Advanced Medical Research Institute, Meili Lake Translational Research Park, Cheeloo College of Medicine, Shenzhen Research Institute of Shandong University, Shandong University, Jinan, Shandong, PR China
| |
Collapse
|
2
|
Amani Hamedani H, Stegall T, Yang Y, Wang H, Menon A, Bhalotia A, Karathanasis E, Capadona JR, Hess-Dunning A. Flexible multifunctional titania nanotube array platform for biological interfacing. MRS BULLETIN 2023; 49:299-309. [PMID: 38645611 PMCID: PMC11026245 DOI: 10.1557/s43577-023-00628-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Accepted: 10/19/2023] [Indexed: 04/23/2024]
Abstract
Abstract The current work presents a novel flexible multifunctional platform for biological interface applications. The use of titania nanotube arrays (TNAs) as a multifunctional material is explored for soft-tissue interface applications. In vitro biocompatibility of TNAs to brain-derived cells was first examined by culturing microglia cells-the resident immune cells of the central nervous system on the surface of TNAs. The release profile of an anti-inflammatory drug, dexamethasone from TNAs-on-polyimide substrates, was then evaluated under different bending modes. Flexible TNAs-on-polyimide sustained a linear release of anti-inflammatory dexamethasone up to ~11 days under different bending conditions. Finally, microfabrication processes for patterning and transferring TNA microsegments were developed to facilitate structural stability during device flexing and to expand the set of compatible polymer substrates. The techniques developed in this study can be applied to integrate TNAs or other similar nanoporous inorganic films onto various polymer substrates. Impact statement Titania nanotube arrays (TNAs) are highly tunable and biocompatible structures that lend themselves to multifunctional implementation in implanted devices. A particularly important aspect of titania nanotubes is their ability to serve as nano-reservoirs for drugs or other therapeutic agents that slowly release after implantation. To date, TNAs have been used to promote integration with rigid, dense tissues for dental and orthopedic applications. This work aims to expand the implant applications that can benefit from TNAs by integrating them onto soft polymer substrates, thereby promoting compatibility with soft tissues. The successful direct growth and integration of TNAs on polymer substrates mark a critical step toward developing mechanically compliant implantable systems with drug delivery from nanostructured inorganic functional materials. Diffusion-driven release kinetics and the high drug-loading efficiency of TNAs offer tremendous potential for sustained drug delivery for scientific investigations, to treat injury and disease, and to promote device integration with biological tissues. This work opens new opportunities for developing novel and more effective implanted devices that can significantly improve patient outcomes and quality of life. Graphical abstract Supplementary information The online version contains supplementary material available at 10.1557/s43577-023-00628-y.
Collapse
Affiliation(s)
- Hoda Amani Hamedani
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, USA
- Department of Materials Science and Engineering, Case Western Reserve University, Cleveland, USA
| | - Thomas Stegall
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
| | - Yi Yang
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, USA
| | - Haochen Wang
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, USA
| | - Ashwin Menon
- Department of Mechanical Engineering, Case Western Reserve University, Cleveland, USA
| | - Anubhuti Bhalotia
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
| | - Efstathios Karathanasis
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
- Case Comprehensive Cancer Center, School of Medicine, Case Western Reserve University, Cleveland, USA
| | - Jeffrey R. Capadona
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
| | - Allison Hess-Dunning
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, USA
| |
Collapse
|
3
|
Palaniyappan K, S. M. N. Mydin RB, Widera D, Noordin SS, Harun NH, Wan Eddis Effendy WN, Hazan R, Sreekantan S. Double-edged sword of biofouling potentials associated with haemocompatibility behaviour: titania nanotube arrays for medical implant surface technology. BENI-SUEF UNIVERSITY JOURNAL OF BASIC AND APPLIED SCIENCES 2023. [DOI: 10.1186/s43088-023-00363-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023] Open
Abstract
Abstract
Background
Medical implant failures are frequently associated with limitations of the surface technology that lead to biofouling and haemocompatibility issues. Titania nanotube array technology could provide a solution for this existing limitation. The present study describes the biofouling potential using the simulated body fluid model according to ISO 23317-2007 and haemocompatibility profiles according to ISO 10993-4 guidelines. Further haemocompatibility profiles were also assessed by evaluating full blood count, coagulation assays, haemolytic rate, whole blood clotting factor, platelet profiles, and FESEM characterization.
Result
Titania nanotube array nanosurface was found to present with better apatite biofouling and hydrophilic potential compared to bare titanium foil. Furthermore, good compatibility behaviour was observed based on the haemocompatibility profiles where no signs of thrombogenesis and haemolysis risks were observed. Titania nanotube array reduced fibrinogen adsorption, red blood cell and platelet adhesion and activation, which could be associated with detrimental biofouling properties.
Conclusion
Titania nanotube array could possess a double-edged sword of biofouling potentials that resist detrimental biofouling properties associated with thrombogenesis and haemolysis risk. It also provides better apatite biofouling potential for improved tissue and osseointegration activities. Knowledge from this study provides a better understanding of medical implant surface technology.
Graphical Abstract
Collapse
|
4
|
Popovich KD, Vagner SA, Murashko DT, Ten GN, Ryabkin DI, Savelyev MS, Kitsyuk EP, Gerasimenko EA, Edelbekova P, Konovalov AN, Telyshev DV, Selishchev SV, Gerasimenko AY. Stability and Thrombogenicity Analysis of Collagen/Carbon Nanotube Nanocomposite Coatings Using a Reversible Microfluidic Device. MEMBRANES 2023; 13:403. [PMID: 37103830 PMCID: PMC10144663 DOI: 10.3390/membranes13040403] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 03/27/2023] [Accepted: 03/30/2023] [Indexed: 06/19/2023]
Abstract
Currently, the development of stable and antithrombogenic coatings for cardiovascular implants is socially important. This is especially important for coatings exposed to high shear stress from flowing blood, such as those on ventricular assist devices. A method of layer-by-layer formation of nanocomposite coatings based on multi-walled carbon nanotubes (MWCNT) in a collagen matrix is proposed. A reversible microfluidic device with a wide range of flow shear stresses has been developed for hemodynamic experiments. The dependence of the resistance on the presence of a cross-linking agent for collagen chains in the composition of the coating was demonstrated. Optical profilometry determined that collagen/c-MWCNT and collagen/c-MWCNT/glutaraldehyde coatings obtained sufficiently high resistance to high shear stress flow. However, the collagen/c-MWCNT/glutaraldehyde coating was almost twice as resistant to a phosphate-buffered solution flow. A reversible microfluidic device made it possible to assess the level of thrombogenicity of the coatings by the level of blood albumin protein adhesion to the coatings. Raman spectroscopy demonstrated that the adhesion of albumin to collagen/c-MWCNT and collagen/c-MWCNT/glutaraldehyde coatings is 1.7 and 1.4 times lower than the adhesion of protein to a titanium surface, widely used for ventricular assist devices. Scanning electron microscopy and energy dispersive spectroscopy determined that blood protein was least detected on the collagen/c-MWCNT coating, which contained no cross-linking agent, including in comparison with the titanium surface. Thus, a reversible microfluidic device is suitable for preliminary testing of the resistance and thrombogenicity of various coatings and membranes, and nanocomposite coatings based on collagen and c-MWCNT are suitable candidates for the development of cardiovascular devices.
Collapse
Affiliation(s)
- Kristina D. Popovich
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Sergey A. Vagner
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
| | - Denis T. Murashko
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Galina N. Ten
- Department of Physics, Saratov State University, Astrakhanskaya Street 83, 410012 Saratov, Russia
| | - Dmitry I. Ryabkin
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Mikhail S. Savelyev
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Evgeny P. Kitsyuk
- Scientific-Manufacturing Complex “Technological Centre”, Shokin Square 1, bld. 7 off. 7237, 124498 Moscow, Russia
| | - Ekaterina A. Gerasimenko
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
- Orthopedic Department, State Autonomous Institution of Health of the City of Moscow, Dental Clinic No.35, Building 1638, Zelenograd, 124365 Moscow, Russia
| | - Polina Edelbekova
- Insitute of Nanotechnology of Microelectronics of the Russian Academy of Sciences, 32a Leninsky Av., 119991 Moscow, Russia
| | | | - Dmitry V. Telyshev
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Sergey V. Selishchev
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| | - Alexander Yu. Gerasimenko
- Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119435 Moscow, Russia
- Institute of Biomedical Systems, National Research University of Electronic Technology, Shokin Square 1, Zelenograd, 124498 Moscow, Russia
| |
Collapse
|
5
|
de Lima IS, Ferreira MOG, Barros EML, Rizzo MDS, Santos JDA, Ribeiro AB, Anteveli Osajima Furtini J, C. Silva-Filho E, Estevinho LM. Antibacterial and Healing Effect of Chicha Gum Hydrogel ( Sterculia striata) with Nerolidol. Int J Mol Sci 2023; 24:2210. [PMID: 36768534 PMCID: PMC9916798 DOI: 10.3390/ijms24032210] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 01/13/2023] [Accepted: 01/17/2023] [Indexed: 01/24/2023] Open
Abstract
Chicha gum is a natural polymer obtained from the Sterculia striata plant. The hydroxyl groups of its structure have a chemical affinity to form hydrogels, which favors the association with biologically active molecules, such as nerolidol. This association improves the biological properties and allows the material to be used in drug delivery systems. Chicha gum hydrogels associated with nerolidol were produced at two concentrations: 0.01 and 0.02 g mL-1. Then, the hydrogels were characterized by thermogravimetry (TG), Fourier Transform Infrared spectroscopy (FTIR), and rheological analysis. The antibacterial activity was tested against Staphylococcus aureus and Escherichia coli. The cytotoxicity was evaluated against Artemia salina. Finally, an in vivo healing assay was carried out. The infrared characterization indicated that interactions were formed during the gel reticulation. This implies the presence of nerolidol in the regions at 3100-3550 cm-1. The rheological properties changed with an increasing concentration of nerolidol, which resulted in less viscous materials. An antibacterial 83.6% growth inhibition effect was observed using the hydrogel with 0.02 g mL-1 nerolidol. The in vivo healing assay showed the practical activity of the hydrogels in the wound treatment, as the materials promoted efficient re-epithelialization. Therefore, it was concluded that the chicha hydrogels have the potential to be used as wound-healing products.
Collapse
Affiliation(s)
- Idglan Sá de Lima
- Interdisciplinary Laboratory of Advanced Materials (LIMAV), Postgraduate Program in Materials Science and Engineering, Federal University of Piauí, Teresina 64049-550, PI, Brazil
| | - Maria Onaira Gonçalves Ferreira
- Interdisciplinary Laboratory of Advanced Materials (LIMAV), Postgraduate Program in Materials Science and Engineering, Federal University of Piauí, Teresina 64049-550, PI, Brazil
| | | | - Marcia dos Santos Rizzo
- Centro de Biotecnologia e Química Fina (CBQF)—Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - Jailson de Araújo Santos
- Interdisciplinary Laboratory of Advanced Materials (LIMAV), Postgraduate Program in Materials Science and Engineering, Federal University of Piauí, Teresina 64049-550, PI, Brazil
| | - Alessandra Braga Ribeiro
- Centro de Biotecnologia e Química Fina (CBQF)—Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - Josy Anteveli Osajima Furtini
- Interdisciplinary Laboratory of Advanced Materials (LIMAV), Postgraduate Program in Materials Science and Engineering, Federal University of Piauí, Teresina 64049-550, PI, Brazil
| | - Edson C. Silva-Filho
- Interdisciplinary Laboratory of Advanced Materials (LIMAV), Postgraduate Program in Materials Science and Engineering, Federal University of Piauí, Teresina 64049-550, PI, Brazil
| | - Leticia M. Estevinho
- Mountain Research Center, CIMO, Polytechnic Institute of Bragança, Campus Santa Apolónia, 5300-253 Bragança, Portugal
| |
Collapse
|
6
|
Zhao X, Cai D, Hu J, Nie J, Chen D, Qin G, Zhang E. A high-hydrophilic Cu 2O-TiO 2/Ti 2O 3/TiO coating on Ti-5Cu alloy: Perfect antibacterial property and rapid endothelialization potential. BIOMATERIALS ADVANCES 2022; 140:213044. [PMID: 35932660 DOI: 10.1016/j.bioadv.2022.213044] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 07/03/2022] [Accepted: 07/20/2022] [Indexed: 02/06/2023]
Abstract
In order to make novel antibacterial Ti-Cu alloy more suitable for cardiovascular implant application, a Cu-containing oxide coating was manufactured on Ti-Cu alloy by plasma-enhanced oxidation deposition in plasma enhanced chemical vapor deposition (PECVD) equipment to further improve the antibacterial ability and the surface bioactivity. The results of X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and water contact angle indicated that a sustainably high-hydrophilic Cu2O-TiO2/Ti2O3/TiO coating with nano-morphology on Ti-5Cu was successfully constructed. The corrosion performance results showed that the coating enhanced the corrosion resistance while releasing more Cu2+, compared with Ti-5Cu. Antibacterial tests confirmed the perfect antibacterial property of the coating (R ≥ 99.9 %), superior to Ti-Cu alloy (R > 90 %). More delightfully, it was observed by phalloidin-FITC and DAPI staining that the coating improved the early adhesion of HUVEC cells mainly due to strong hydrophilicity and nano-morphology. It was demonstrated that the extract of the coated sample significantly promoted proliferation (RGR = 112 %-138 % after cultivation for 1 to 3 days) and migration of HUVEC cells due to the appropriate Cu2+ release concentration. Hemolysis assay and platelet adhesion results showed that the coating had excellent blood compatibility. All results suggested that the coating on Ti-Cu alloy might be a promising surface with the perfect antibacterial ability, blood compatibility and evident promoting endothelialization ability for the cardiovascular application.
Collapse
Affiliation(s)
- Xiaotong Zhao
- Key Lab. for Anisotropy and Texture of Materials, Education Ministry of China, School of Materials Science and Engineering, Northeastern University, Shenyang 110819, China
| | - Diangeng Cai
- Key Lab. for Anisotropy and Texture of Materials, Education Ministry of China, School of Materials Science and Engineering, Northeastern University, Shenyang 110819, China
| | - Jiali Hu
- Key Lab. for Anisotropy and Texture of Materials, Education Ministry of China, School of Materials Science and Engineering, Northeastern University, Shenyang 110819, China
| | - Jingjun Nie
- Laboratory of Bone tissue engineering, Beijing Laboratory of biomedical materials, Beijing Research Institute of Orthopaedics and Traumatology, Beijing Jishuitan Hospital, Beijing 100035, China
| | - Dafu Chen
- Laboratory of Bone tissue engineering, Beijing Laboratory of biomedical materials, Beijing Research Institute of Orthopaedics and Traumatology, Beijing Jishuitan Hospital, Beijing 100035, China.
| | - Gaowu Qin
- Key Lab. for Anisotropy and Texture of Materials, Education Ministry of China, School of Materials Science and Engineering, Northeastern University, Shenyang 110819, China; Research Center for Metallic Wires, Northeastern University, Shenyang 110819, China
| | - Erlin Zhang
- Key Lab. for Anisotropy and Texture of Materials, Education Ministry of China, School of Materials Science and Engineering, Northeastern University, Shenyang 110819, China; Research Center for Metallic Wires, Northeastern University, Shenyang 110819, China.
| |
Collapse
|
7
|
Nair VS, Nachimuthu R. The role of NiTi shape memory alloys in quality of life improvement through medical advancements: A comprehensive review. Proc Inst Mech Eng H 2022; 236:923-950. [PMID: 35486134 DOI: 10.1177/09544119221093460] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The significance of advanced smart materials in recent technological research and advancement is apparent from its extensive use in present day devices and instruments. Of the various smart materials in use today, the fascinating category of shape memory alloys (SMAs) is equipped with the ability to return to a previously memorized shape under certain thermomechanical or magnetic stimuli. The unique property of shape memory effect and superelasticity displayed by these materials along with good biocompatibility and corrosion resistance make them ideal for biomedical applications. The various applications of SMAs in surgical instruments, surgical implants, and assistive and rehabilitative devices have significant effect on the day to day life of people in the present age. Majority of these biomedical devices belong to the orthodontic, orthopedic, or surgical fields. Other remarkable applications of SMAs such as in the production of prostheses and orthoses designed through the biomimetic approach are also highly influential in improving the quality of life. The present paper provides an overview of the various properties of shape memory alloys and their applications in the biomedical field over the years, that have had a significant impact on the realm of medical science.
Collapse
Affiliation(s)
- Viswajith S Nair
- Department of Mechanical Engineering, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore, India
| | - Radhika Nachimuthu
- Department of Mechanical Engineering, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore, India
| |
Collapse
|
8
|
Zhang J, Li G, Qu Y, Guo Z, Zhang S, Li D. Fabrication and Hemocompatibility Evaluation of a Robust Honeycomb Nanostructure on Medical Pure Titanium Surface. ACS APPLIED MATERIALS & INTERFACES 2022; 14:9807-9823. [PMID: 35084192 DOI: 10.1021/acsami.1c22818] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Thrombosis induced by blood-contacting medical devices is still a major clinical problem, resulting in some serious complications such as infarction, irreversible tissue damage, and even death. Therefore, seeking an effective and safe surface modification approach to improve the hemocompatibility of the material is still urgent. In this research, a novel and facile approach was proposed to fabricate a robust honeycomb nanostructure on medical pure titanium surface by two-step anodic oxidation, which effectively enhanced the physicochemical performance and hemocompatibility of the material. Especially, the honeycomb nanostructure that underwent annealing treatment at 500 °C (HN-Ti-500 °C) presented significant performance to suppress the coagulation cascade in the in vitro tests, the reason mainly ascribed to an overall repulsive interaction between the protein molecule related to thrombosis and material surface based on an extended Derjaguin-Landau-Verwey-Overbeek (XDLVO) theory analysis. Furthermore, a vessel stent fabricated by HN-Ti-500 °C was implanted into the left carotid artery of rabbits for 1 month. The antithrombotic mechanism and biocompatibility of the modified surface were further verified. The results presented that no thrombus generated and adhered onto the inner surface of the modified stent, and no obvious disorder hyperplasia and inflammation were observed in the intima tissue of the vessel at the implantation site, which indicated that the modified surface could effectively decrease the risk of in-stent restenosis and thrombosis. This work offers a promising strategy for surface modification of blood-contacting medical titanium material to address the clinical complications associated with restenosis and thrombosis.
Collapse
Affiliation(s)
- Jing Zhang
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, P. R. China
- Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, P. R. China
| | - Guiling Li
- Advanced Medical Research Institute, Shandong University, Jinan 250012, P. R. China
| | - Yifei Qu
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, P. R. China
- Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, P. R. China
| | - Ziyu Guo
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, P. R. China
- Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, P. R. China
| | - Song Zhang
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250061, P. R. China
- Key National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, P. R. China
| | - Donghai Li
- Advanced Medical Research Institute, Shandong University, Jinan 250012, P. R. China
| |
Collapse
|
9
|
Gardin C, Ferroni L, Erdoğan YK, Zanotti F, De Francesco F, Trentini M, Brunello G, Ercan B, Zavan B. Nanostructured Modifications of Titanium Surfaces Improve Vascular Regenerative Properties of Exosomes Derived from Mesenchymal Stem Cells: Preliminary In Vitro Results. NANOMATERIALS 2021; 11:nano11123452. [PMID: 34947800 PMCID: PMC8707709 DOI: 10.3390/nano11123452] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/05/2021] [Accepted: 12/09/2021] [Indexed: 01/02/2023]
Abstract
(1) Background: Implantation of metal-based scaffolds is a common procedure for treating several diseases. However, the success of the long-term application is limited by an insufficient endothelialization of the material surface. Nanostructured modifications of metal scaffolds represent a promising approach to faster biomaterial osteointegration through increasing of endothelial commitment of the mesenchymal stem cells (MSC). (2) Methods: Three different nanotubular Ti surfaces (TNs manufactured by electrochemical anodization with diameters of 25, 80, or 140 nm) were seeded with human MSCs (hMSCs) and their exosomes were isolated and tested with human umbilical vein endothelial cells (HUVECs) to assess whether TNs can influence the secretory functions of hMSCs and whether these in turn affect endothelial and osteogenic cell activities in vitro. (3) Results: The hMSCs adhered on all TNs and significantly expressed angiogenic-related factors after 7 days of culture when compared to untreated Ti substrates. Nanomodifications of Ti surfaces significantly improved the release of hMSCs exosomes, having dimensions below 100 nm and expressing CD63 and CD81 surface markers. These hMSC-derived exosomes were efficiently internalized by HUVECs, promoting their migration and differentiation. In addition, they selectively released a panel of miRNAs directly or indirectly related to angiogenesis. (4) Conclusions: Preconditioning of hMSCs on TNs induced elevated exosomes secretion that stimulated in vitro endothelial and cell activity, which might improve in vivo angiogenesis, supporting faster scaffold integration.
Collapse
Affiliation(s)
- Chiara Gardin
- Maria Cecilia Hospital, GVM Care & Research, Cotignola, 48033 Ravenna, Italy; (C.G.); (L.F.)
| | - Letizia Ferroni
- Maria Cecilia Hospital, GVM Care & Research, Cotignola, 48033 Ravenna, Italy; (C.G.); (L.F.)
| | - Yaşar Kemal Erdoğan
- Biomedical Engineering Program, Middle East Technical University, Ankara 06800, Turkey; (Y.K.E.); (B.E.)
- Department of Biomedical Engineering, Isparta University of Applied Science, Isparta 32260, Turkey
| | - Federica Zanotti
- Department of Translational Medicine, University of Ferrara, 44121 Ferrara, Italy; (F.Z.); (M.T.)
| | - Francesco De Francesco
- Department of Plastic and Reconstructive Surgery-Hand Surgery Unit, Azienda ‘Ospedali Riuniti’, 60126 Ancona, Italy;
| | - Martina Trentini
- Department of Translational Medicine, University of Ferrara, 44121 Ferrara, Italy; (F.Z.); (M.T.)
| | - Giulia Brunello
- Department of Neurosciences, Dentistry Section, University of Padova, 35128 Padova, Italy;
- Department of Oral Surgery, University Clinic Düsseldorf, 40225 Dusseldorf, Germany
| | - Batur Ercan
- Biomedical Engineering Program, Middle East Technical University, Ankara 06800, Turkey; (Y.K.E.); (B.E.)
- Department of Metallurgical and Materials Engineering, Middle East Technical University, Ankara 06800, Turkey
- BIOMATEN, METU Center of Excellence in Biomaterials and Tissue Engineering, Ankara 06800, Turkey
| | - Barbara Zavan
- Department of Translational Medicine, University of Ferrara, 44121 Ferrara, Italy; (F.Z.); (M.T.)
- Correspondence: ; Tel.: +39-0532455502
| |
Collapse
|
10
|
Raval J, Gongadze E, Benčina M, Junkar I, Rawat N, Mesarec L, Kralj-Iglič V, Góźdź W, Iglič A. Mechanical and Electrical Interaction of Biological Membranes with Nanoparticles and Nanostructured Surfaces. MEMBRANES 2021; 11:membranes11070533. [PMID: 34357183 PMCID: PMC8307671 DOI: 10.3390/membranes11070533] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 07/05/2021] [Accepted: 07/05/2021] [Indexed: 11/27/2022]
Abstract
In this review paper, we theoretically explain the origin of electrostatic interactions between lipid bilayers and charged solid surfaces using a statistical mechanics approach, where the orientational degree of freedom of lipid head groups and the orientational ordering of the water dipoles are considered. Within the modified Langevin Poisson–Boltzmann model of an electric double layer, we derived an analytical expression for the osmotic pressure between the planar zwitterionic lipid bilayer and charged solid planar surface. We also show that the electrostatic interaction between the zwitterionic lipid head groups of the proximal leaflet and the negatively charged solid surface is accompanied with a more perpendicular average orientation of the lipid head-groups. We further highlight the important role of the surfaces’ nanostructured topography in their interactions with biological material. As an example of nanostructured surfaces, we describe the synthesis of TiO2 nanotubular and octahedral surfaces by using the electrochemical anodization method and hydrothermal method, respectively. The physical and chemical properties of these nanostructured surfaces are described in order to elucidate the influence of the surface topography and other physical properties on the behavior of human cells adhered to TiO2 nanostructured surfaces. In the last part of the paper, we theoretically explain the interplay of elastic and adhesive contributions to the adsorption of lipid vesicles on the solid surfaces. We show the numerically predicted shapes of adhered lipid vesicles corresponding to the minimum of the membrane free energy to describe the influence of the vesicle size, bending modulus, and adhesion strength on the adhesion of lipid vesicles on solid charged surfaces.
Collapse
Affiliation(s)
- Jeel Raval
- Group of Physical Chemistry of Complex Systems, Institute of Physical Chemistry, Polish Academy of Sciences, 01-224 Warsaw, Poland; (J.R.); (W.G.)
| | - Ekaterina Gongadze
- Laboratory of Physics, Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia; (E.G.); (N.R.); (L.M.)
| | - Metka Benčina
- Department of Surface Engineering and Optoelectronics, Jožef Stefan Institute, 1000 Ljubljana, Slovenia; (M.B.); (I.J.)
| | - Ita Junkar
- Department of Surface Engineering and Optoelectronics, Jožef Stefan Institute, 1000 Ljubljana, Slovenia; (M.B.); (I.J.)
| | - Niharika Rawat
- Laboratory of Physics, Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia; (E.G.); (N.R.); (L.M.)
| | - Luka Mesarec
- Laboratory of Physics, Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia; (E.G.); (N.R.); (L.M.)
| | - Veronika Kralj-Iglič
- Laboratory of Clinical Biophysics, Faculty of Health Sciences, University of Ljubljana, 1000 Ljubljana, Slovenia;
| | - Wojciech Góźdź
- Group of Physical Chemistry of Complex Systems, Institute of Physical Chemistry, Polish Academy of Sciences, 01-224 Warsaw, Poland; (J.R.); (W.G.)
| | - Aleš Iglič
- Laboratory of Physics, Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia; (E.G.); (N.R.); (L.M.)
- Laboratory of Clinical Biophysics, Chair of Orthopaedics, Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia
- Correspondence: ; Tel.: +386-1-4768-825
| |
Collapse
|
11
|
Cherian AM, Nair SV, Maniyal V, Menon D. Surface engineering at the nanoscale: A way forward to improve coronary stent efficacy. APL Bioeng 2021; 5:021508. [PMID: 34104846 PMCID: PMC8172248 DOI: 10.1063/5.0037298] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 04/26/2021] [Indexed: 12/12/2022] Open
Abstract
Coronary in-stent restenosis and late stent thrombosis are the two major inadequacies of vascular stents that limit its long-term efficacy. Although restenosis has been successfully inhibited through the use of the current clinical drug-eluting stent which releases antiproliferative drugs, problems of late-stent thrombosis remain a concern due to polymer hypersensitivity and delayed re-endothelialization. Thus, the field of coronary stenting demands devices having enhanced compatibility and effectiveness to endothelial cells. Nanotechnology allows for efficient modulation of surface roughness, chemistry, feature size, and drug/biologics loading, to attain the desired biological response. Hence, surface topographical modification at the nanoscale is a plausible strategy to improve stent performance by utilizing novel design schemes that incorporate nanofeatures via the use of nanostructures, particles, or fibers, with or without the use of drugs/biologics. The main intent of this review is to deliberate on the impact of nanotechnology approaches for stent design and development and the recent advancements in this field on vascular stent performance.
Collapse
Affiliation(s)
- Aleena Mary Cherian
- Amrita Centre for Nanosciences and Molecular Medicine, Amrita
Vishwa Vidyapeetham, Ponekkara P.O. Cochin 682041, Kerala,
India
| | - Shantikumar V. Nair
- Amrita Centre for Nanosciences and Molecular Medicine, Amrita
Vishwa Vidyapeetham, Ponekkara P.O. Cochin 682041, Kerala,
India
| | - Vijayakumar Maniyal
- Department of Cardiology, Amrita Institute of Medical Science
and Research Centre, Amrita Vishwa Vidyapeetham, Ponekkara P.O. Cochin
682041, Kerala, India
| | - Deepthy Menon
- Amrita Centre for Nanosciences and Molecular Medicine, Amrita
Vishwa Vidyapeetham, Ponekkara P.O. Cochin 682041, Kerala,
India
| |
Collapse
|
12
|
Yu Y, Liang C, Xu R, Wang T, Deng F, Yu X. Titanium implant alters the effect of zoledronic acid on the behaviour of endothelial cells. Oral Dis 2021; 28:1968-1978. [PMID: 33908127 DOI: 10.1111/odi.13890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 04/03/2021] [Accepted: 04/16/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To evaluate the effect of zoledronic acid (ZA) on human umbilical vein endothelial cells (HUVECs) attached to different surfaces. MATERIALS AND METHODS A total of three groups were evaluated in this study: sandblasting and acid etching (SLA) + HUVECs; mechanically polished (MP) + HUVECs; and plastic cell culture plates + HUVECs. Scanning electron microscopy, energy-dispersive X-ray spectroscopy, surface roughness and water contact angle were tested for titanium surface characterisation. ZA was added at different concentrations (0, 1, 10, 50 and 100 μM). Cell adhesion, proliferation, viability, apoptosis and gene expression were evaluated. RESULTS Mechanically polished and SLA surfaces showed negative effects on cell adhesion and proliferation and promoted cell apoptosis with 100 μM ZA (p < .05). The highest expression of intercellular adhesion molecule-1 (ICAM-1) and angiopoietin-1 was found on SLA surfaces (p < .01). The lowest expression of platelet-endothelial cell adhesion molecule-1 and ICAM-1 was found on MP surfaces (p < .05). A significant decrease in von Willebrand factor was detected on MP and SLA surfaces (p < .001). CONCLUSIONS Zoledronic acid has an anti-angiogenic effect on HUVECs attached to titanium implants, while the SLA surface might stimulate HUVECs to express angiogenic and adhesive factor genes despite ZA treatment.
Collapse
Affiliation(s)
- Yi Yu
- Department of Oral Implantology, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, China
| | - Chaoan Liang
- Department of Oral Implantology, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, China
| | - Ruogu Xu
- Department of Oral Implantology, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, China
| | - Tianlu Wang
- Department of Oral Implantology, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, China
| | - Feilong Deng
- Department of Oral Implantology, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, China
| | - Xiaolin Yu
- Department of Oral Implantology, Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, China
| |
Collapse
|
13
|
Montgomerie Z, Popat KC. Improved hemocompatibility and reduced bacterial adhesion on superhydrophobic titania nanoflower surfaces. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 119:111503. [PMID: 33321602 PMCID: PMC7744674 DOI: 10.1016/j.msec.2020.111503] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/02/2020] [Accepted: 09/09/2020] [Indexed: 12/13/2022]
Abstract
Thrombosis formation and bacterial infection are key challenges for blood-contacting medical devices. When blood components encounter a device's surface, proteins are adsorbed, followed by the adhesion and activation of platelets as well as an immune response. This culminates in clot formation via the trapping of red blood cells in a fibrin matrix, which can block the device's function and cause severe complications for the patient. In addition, bacteria may adhere to a device's surface. This can lead to the formation of a biofilm, a protective layer for bacteria that significantly increases resistance to antibiotics. Despite years of research, no long-term solutions have been discovered to combat these issues. To impede thrombosis, patients often take antiplatelet drugs for the life of their device, which can cause excess bleeding and other complications. Patients can take antibiotics to fight bacterial infection, but these are often ineffective if biofilms are formed. Superhydrophobic surfaces show promise in reducing both thrombosis and bacterial infection on devices by impeding contact between biological components and the biomaterial. In this study, superhydrophobic titania nanoflower surfaces were successfully fabricated on a titanium alloy Ti-6Al-4V substrate with hydrothermal synthesis and vapor-phase silanization. The surface topography, surface wettability, surface chemistry, and surface crystallography of the surfaces was subsequently characterized. Surface hemocompatibility was investigated through lactate dehydrogenase (LDH) cytotoxicity analysis, blood-plasma protein adsorption, platelet and leukocyte adhesion and activation, and whole blood clotting analysis. Surface bacterial infection was characterized through Gram-positive and Gram-negative bacterial adhesion and biofilm morphology. The results indicated a reduction of protein adsorption, platelet and leukocyte adhesion and activation, bacterial adhesion, and biofilm formation as well as improved contact angle stability compared to control surfaces.
Collapse
Affiliation(s)
- Zachary Montgomerie
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Ketul C Popat
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA; School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA; School of Advanced Materials Discovery, Colorado State University, Fort Collins, CO 80523, USA.
| |
Collapse
|
14
|
Nanostructured Titanium for Improved Endothelial Biocompatibility and Reduced Platelet Adhesion in Stent Applications. COATINGS 2020. [DOI: 10.3390/coatings10090907] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Although coronary stents have improved the early and long-term consequences of arterial lesions, the prevention of restenosis and late stent thrombosis is key to prevent a new obstruction of the vessel. Here we aimed at improving the tissue response to stents through surface modification. For that purpose, we used two different approaches, the use of nanostructuration by electrochemical anodization and the addition of a quercitrin (QR) coating to the Ti surface. Four surfaces (Ti, NN, TiQR and NNQR) were characterized by atomic force microscopy, scanning electronic microscopy and contact angle analysis and QR content was evaluated by fluorescent staining. Cell adhesion, cytotoxicity, metabolic activity and nitric oxide (NO) production was evaluated on primary human umbilical cord endothelial cells (HUVECs). Platelet adhesion, hemolysis rate and Staphylococcus epidermidis CECT 4184 adhesion at 30 min were analyzed. Nanostructuration induced an increase on surface roughness, and QR coating decreased the contact angle. All surfaces were biocompatible, with no hemolysis rate and lower platelet adhesion was found in NN surfaces. Finally, S. epidermidis adhesion was lower on TiQR surfaces compared to Ti. In conclusion, our results suggest that NN structuration could improve biocompatibility of bare metal stents on endothelial cells and reduce platelet adhesion. Moreover, QR coating could reduce bacterial adhesion.
Collapse
|
15
|
Elblbesy MA, Hanafy TA, Kandil BA. Effect of gelatin concentration on the characterizations and hemocompatibility of polyvinyl alcohol-gelatin hydrogel. Biomed Mater Eng 2020; 31:225-234. [PMID: 32716341 DOI: 10.3233/bme-201096] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The design and fabrication of hemocompatible and low-toxicity formulations remains a challenging task. Hydrogels are of considerable importance for biomedical applications since they are highly compatible with living tissue, both in vivo and in vitro. OBJECTIVE The present study aimed to develop and evaluate the characterizations and in vitro hemocompatibility of a hydrogel using polyvinyl alcohol and gelatin with different concentrations. METHODS The gelling process was realized by cross-linking the polyvinyl alcohol and gelatin. The morphological and structural examinations of the synthetic hydrogels were done by scanning electron microscopy (SEM) and X-ray powder diffraction (XRD). The swelling behavior of the prepared hydrogels in water was evaluated. Prothrombin time, activated partial thromboplastin time, and thrombin time were measured, and a hemolysis test was done to evaluate the hemocompatibility of prepared hydrogels. RESULTS The increase of the gelatin concentration in polyvinyl gelatin hydrogel increases the porosity and enhances the absorptivity of the prepared hydrogel. The measured hematological parameters indicated enhancement of hemocompatibility as the gelatin concentration was increased in the prepared hydrogel. CONCLUSIONS The results obtained from this study confirm that gelatin was able to improve the properties of the polyvinyl alcohol-gelatin hydrogel and enhance the hemocompatibility. Thus, the prepared hydrogel could be used in a variety of biomedical applications.
Collapse
Affiliation(s)
- Mohamed A Elblbesy
- Department of Medical Biophysics, Medical Research Institute, Alexandria University, Egypt.,Department of Medical Laboratory Technology, Faculty of Applied Medical Sciences, University of Tabuk, Saudi Arabia
| | - Taha A Hanafy
- Nanotechnology Research Laboratory, Department of Physics, Faculty of Science, University of Tabuk, Saudi Arabia.,Physics Department, Faculty of Science, El Fayoum University, Egypt
| | - Bothaina A Kandil
- Department of Radiological Science and Medical Imaging, Faculty of Allied Medical Science, Pharos University, Egypt
| |
Collapse
|
16
|
Cherian A, Joseph J, Nair MB, Nair SV, Maniyal V, Menon D. Successful Reduction of Neointimal Hyperplasia on Stainless Steel Coronary Stents by Titania Nanotexturing. ACS OMEGA 2020; 5:17582-17591. [PMID: 32715243 PMCID: PMC7377224 DOI: 10.1021/acsomega.0c02045] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Accepted: 06/22/2020] [Indexed: 06/11/2023]
Abstract
Bare metal stents (BMSs) of stainless steel (SS) were surface engineered to develop nanoscale titania topography using a combination of physical vapor deposition and thermochemical processing. The nanoleafy architecture formed on the stent surface remained stable and adherent upon repeated crimping and expansion, as well as under flow. This titania nanoengineered stent showed a preferential proliferation of endothelial cells over smooth muscle cells in vitro, which is an essential requirement for improving the in vivo endothelialization, with concurrent reduction of intimal hyperplasia. The efficacy of this surface-modified stent was assessed after implantation in rabbit iliac arteries for 8 weeks. Significant reduction in neointimal thickening and thereby in-stent restenosis with complete endothelial coverage was observed for the nanotextured stents, compared to BMSs, even without the use of any antiproliferative agents or polymers as in drug-eluting stents. Nanotexturing of stents did not induce any inflammatory response, akin to BMSs. This study thus indicates the effectiveness of a facile titania nanotopography on SS stents for coronary applications and the possibility of bringing this low-priced material back to clinics.
Collapse
Affiliation(s)
- Aleena
Mary Cherian
- Amrita
Centre for Nanosciences and Molecular Medicine, Amrita Vishwa Vidyapeetham, Ponekkara P.O, Cochin, 682041 Kerala, India
| | - John Joseph
- Amrita
Centre for Nanosciences and Molecular Medicine, Amrita Vishwa Vidyapeetham, Ponekkara P.O, Cochin, 682041 Kerala, India
| | - Manitha B. Nair
- Amrita
Centre for Nanosciences and Molecular Medicine, Amrita Vishwa Vidyapeetham, Ponekkara P.O, Cochin, 682041 Kerala, India
| | - Shantikumar V. Nair
- Amrita
Centre for Nanosciences and Molecular Medicine, Amrita Vishwa Vidyapeetham, Ponekkara P.O, Cochin, 682041 Kerala, India
| | - Vijayakumar Maniyal
- Department
of Cardiology, Amrita Institute of Medical Science and Research Centre, Amrita Vishwa Vidyapeetham, Ponekkara P.O, Cochin, 682041 Kerala, India
| | - Deepthy Menon
- Amrita
Centre for Nanosciences and Molecular Medicine, Amrita Vishwa Vidyapeetham, Ponekkara P.O, Cochin, 682041 Kerala, India
| |
Collapse
|
17
|
Park KS, Kang SN, Kim DH, Kim HB, Im KS, Park W, Hong YJ, Han DK, Joung YK. Late endothelial progenitor cell-capture stents with CD146 antibody and nanostructure reduce in-stent restenosis and thrombosis. Acta Biomater 2020; 111:91-101. [PMID: 32434081 DOI: 10.1016/j.actbio.2020.05.011] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 05/08/2020] [Accepted: 05/08/2020] [Indexed: 12/13/2022]
Abstract
The restoration of damaged endothelium is promising to reduce side effects, including restenosis and thrombosis, in the stent treatment for vascular diseases. Current technologies based on drug delivery for these complications still do not satisfy patients due to invariant recurrence rate. Recently, even if one approach was applied to clinical trial to develop the firstly commercialized stent employing circulating endothelial progenitor cells (EPCs) in blood vessels, it resulted in failure in clinical trial. Based on instruction of the failed case, we designed an advanced EPC-capture stent covered with anti-CD146 antibody (Ab) immobilized silicone nanofilament (SiNf) for the highly efficient and specific capture of not early but late stage of EPCs. In vitro cell capture test demonstrates enhanced capture efficiency and adhesion morphology of late EPCs on the modified substrate. The modified substrates could capture 8 times more late EPCs and even 3 times more mesenchymal stem cells (MSCs) as compared to unmodified one. A porcine model with high similarity to human reproduced in vivo results ideally translated from in vitro cell capture results. As restenosis indicators, lumen area, neointimal rate and stenosis area for modified stents were reduced at the range of 30-60% as compared to those for bare metal stent (BMS). Fibrin score indicating thrombosis was lowered less than half as comparing to that on BMS. These inspiring results are attributed to ~2-fold increased endothelial coverage, determined by immuno-histological staining. Taken together, the CD146 Ab-armed nanofilamentous stent could show great performance in the reduction of thrombosis and restenosis through re-endothelialization due to highly efficient specific cell capture. STATEMENT OF SIGNIFICANCE: Stents have been developed from simple metal stents to functionalized stents for past decades. However, they have still risks to relapse the occlusion in stented arteries. In this paper, we describe the fabrication and optimization of cell capturing stents to maximize the effective re-endothelialization through the serial coating of silicone nanofilaments and anti-CD146 antibody. The nanofilaments increase the amount of coated antibodies and provide the anchoring points of circulating angiogenic cells for strong focal adhesion. We demonstrate high immobilizing ability of circulating angiogenic cells (endotheliali progenitor cells and mesenchymal stem cells) in vitro under similar shear stress to coronary arteries (15 dyne/cm2). Also, we show accelerating re-endothelialization and the efficient prevention of restenosis in porcine coronary arteries in vivo.
Collapse
Affiliation(s)
- Kwang-Sook Park
- Center for Biomaterials, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
| | - Sung Nam Kang
- Center for Biomaterials, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Department of Biomedical Engineering, Korea University of Science and Technology, Daejeon 34113, Republic of Korea
| | - Dae Hwan Kim
- Center for Biomaterials, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
| | - Han-Byual Kim
- The Heart Center of Chonnam National University Hospital, Gwangju 61469, Republic of Korea
| | - Kyung Seob Im
- Futuristic Animal Resource & Research Center, Korea Research Institute of Bioscience and Biotechnology, Cheongju 28116, Republic of Korea
| | - Wooram Park
- Department of Biomedical Science, College of Life Sciences, CHA University, Gyeonggi 13488, Republic of Korea
| | - Young Joon Hong
- The Heart Center of Chonnam National University Hospital, Gwangju 61469, Republic of Korea
| | - Dong Keun Han
- Department of Biomedical Science, College of Life Sciences, CHA University, Gyeonggi 13488, Republic of Korea.
| | - Yoon Ki Joung
- Center for Biomaterials, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Department of Biomedical Engineering, Korea University of Science and Technology, Daejeon 34113, Republic of Korea.
| |
Collapse
|
18
|
Benčina M, Iglič A, Mozetič M, Junkar I. Crystallized TiO 2 Nanosurfaces in Biomedical Applications. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E1121. [PMID: 32517276 PMCID: PMC7353402 DOI: 10.3390/nano10061121] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 06/02/2020] [Accepted: 06/04/2020] [Indexed: 12/25/2022]
Abstract
Crystallization alters the characteristics of TiO2 nanosurfaces, which consequently influences their bio-performance. In various biomedical applications, the anatase or rutile crystal phase is preferred over amorphous TiO2. The most common crystallization technique is annealing in a conventional furnace. Methods such as hydrothermal or room temperature crystallization, as well as plasma electrolytic oxidation (PEO) and other plasma-induced crystallization techniques, present more feasible and rapid alternatives for crystal phase initiation or transition between anatase and rutile phases. With oxygen plasma treatment, it is possible to achieve an anatase or rutile crystal phase in a few seconds, depending on the plasma conditions. This review article aims to address different crystallization techniques on nanostructured TiO2 surfaces and the influence of crystal phase on biological response. The emphasis is given to electrochemically anodized nanotube arrays and their interaction with the biological environment. A short overview of the most commonly employed medical devices made of titanium and its alloys is presented and discussed.
Collapse
Affiliation(s)
- Metka Benčina
- Department of Surface Engineering and Optoelectronics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia; (M.M.); (I.J.)
| | - Aleš Iglič
- Laboratory of Physics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, SI-1000 Ljubljana, Slovenia;
- Faculty of Medicine, University of Ljubljana, Zaloška 9, SI-1000 Ljubljana, Slovenia
| | - Miran Mozetič
- Department of Surface Engineering and Optoelectronics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia; (M.M.); (I.J.)
| | - Ita Junkar
- Department of Surface Engineering and Optoelectronics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia; (M.M.); (I.J.)
| |
Collapse
|
19
|
Junkar I, Kulkarni M, Benčina M, Kovač J, Mrak-Poljšak K, Lakota K, Sodin-Šemrl S, Mozetič M, Iglič A. Titanium Dioxide Nanotube Arrays for Cardiovascular Stent Applications. ACS OMEGA 2020; 5:7280-7289. [PMID: 32280869 PMCID: PMC7144139 DOI: 10.1021/acsomega.9b04118] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 03/05/2020] [Indexed: 05/13/2023]
Abstract
Efficient stent implantation among others depends on avoiding the aggregation of platelets in the blood vessels and appropriate proliferation of endothelial cells and controlled proliferation of smooth muscle cells, which reduces the development of pathology, such as neointimal hyperplasia, thrombosis, and restenosis. The current article provides an elegant solution for prevention of platelet and smooth muscle cell adhesion and activation on stent surfaces while obtaining surface conditions to support the growth of human coronary artery endothelial cells. This was achieved by surface nanostructuring and chemical activation of the surface. Specific nanotopographies of titanium were obtained by electrochemical anodization, while appropriate chemical properties were attained by treatment of titanium oxide nanotubes by highly reactive oxygen plasma. Surface properties were studied by scanning electron microscopy, atomic force microscopy, and X-ray photoelectron spectroscopy. Wettability was evaluated by measuring the water contact angle. The influence of nanostructured morphology and plasma modification on in vitro biological response with human coronary artery endothelia and smooth muscle cells as well as whole blood was studied. Our results show that a combination of nanostructuring and plasma modification of the surfaces is an effective way to achieve desired biological responses necessary for implantable materials such as stents.
Collapse
Affiliation(s)
- Ita Junkar
- Department
of Surface Engineering and Optoelectronics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
- . Tel. no.: +38614473885
| | - Mukta Kulkarni
- Laboratory
of Biophysics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, SI-1000 Ljubljana, Slovenia
| | - Metka Benčina
- Department
of Surface Engineering and Optoelectronics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Janez Kovač
- Department
of Surface Engineering and Optoelectronics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Katjuša Mrak-Poljšak
- Department
of Rheumatology, University Medical Centre
Ljubljana, Vodnikova 62, SI-1000 Ljubljana, Slovenia
| | - Katja Lakota
- Department
of Rheumatology, University Medical Centre
Ljubljana, Vodnikova 62, SI-1000 Ljubljana, Slovenia
| | - Snežna Sodin-Šemrl
- Department
of Rheumatology, University Medical Centre
Ljubljana, Vodnikova 62, SI-1000 Ljubljana, Slovenia
| | - Miran Mozetič
- Department
of Surface Engineering and Optoelectronics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Aleš Iglič
- Laboratory
of Biophysics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, SI-1000 Ljubljana, Slovenia
- Faculty
of Medicine, University of Ljubljana, Vrazov trg 2, SI-1000 Ljubljana, Slovenia
| |
Collapse
|
20
|
Bilek O, Fialova T, Otahal A, Adam V, Smerkova K, Fohlerova Z. Antibacterial activity of AgNPs–TiO 2 nanotubes: influence of different nanoparticle stabilizers. RSC Adv 2020; 10:44601-44610. [PMID: 35517148 PMCID: PMC9058477 DOI: 10.1039/d0ra07305a] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Accepted: 12/01/2020] [Indexed: 01/22/2023] Open
Abstract
Enhanced antibacterial properties of nanomaterials such as TiO2 nanotubes (TNTs) and silver nanoparticles (AgNPs) have attracted much attention in biomedicine and industry. The antibacterial properties of nanoparticles depend, among others, on the functionalization layer of the nanoparticles. However, the more complex information about the influence of different functionalization layers on antibacterial properties of nanoparticle decorated surfaces is still missing. Here we show the array of ∼50 nm diameter TNTs decorated with ∼50 nm AgNPs having different functionalization layers such as polyvinylpyrrolidone, branched polyethyleneimine, citrate, lipoic acid, and polyethylene glycol. To assess the antibacterial properties, the viability of Gram-positive (Staphylococcus aureus) and Gram-negative bacteria (Escherichia coli and Pseudomonas aeruginosa) has been assessed. Our results showed that the functional layer of nanoparticles plays an important role in antibacterial properties and the synergistic effect such nanoparticles and TiO2 nanotubes have had different effects on adhesion and viability of G− and G+ bacteria. These findings could help researchers to optimally design any surfaces to be used as an antibacterial including the implantable titanium biomaterials. Synergictic antibacterial effect of AgNPs–TiO2 nanotubes is influenced by different nanoparticle stabilizers.![]()
Collapse
Affiliation(s)
- Ondrej Bilek
- Central European Institute of Technology
- Brno University of Technology
- Brno
- Czech Republic
| | - Tatiana Fialova
- Department of Chemistry and Biochemistry
- Mendel University in Brno
- Brno
- Czech Republic
| | - Alexandr Otahal
- Department of Microelectronics
- Brno University of Technology
- Brno
- Czech Republic
| | - Vojtech Adam
- Central European Institute of Technology
- Brno University of Technology
- Brno
- Czech Republic
- Department of Chemistry and Biochemistry
| | - Kristyna Smerkova
- Central European Institute of Technology
- Brno University of Technology
- Brno
- Czech Republic
- Department of Chemistry and Biochemistry
| | - Zdenka Fohlerova
- Central European Institute of Technology
- Brno University of Technology
- Brno
- Czech Republic
- Department of Microelectronics
| |
Collapse
|
21
|
Safari Z, Soudi S, Jafarzadeh N, Hosseini AZ, Vojoudi E, Sadeghizadeh M. Promotion of angiogenesis by M13 phage and RGD peptide in vitro and in vivo. Sci Rep 2019; 9:11182. [PMID: 31371773 PMCID: PMC6672002 DOI: 10.1038/s41598-019-47413-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Accepted: 07/16/2019] [Indexed: 01/11/2023] Open
Abstract
One of the most important goals of regenerative medicines is to generate alternative tissues with a developed vascular network. Endothelial cells are the most important cell type required in angiogenesis process, contributing to the blood vessels formation. The stimulation of endothelial cells to initiate angiogenesis requires appropriate extrinsic signals. The aim of this study was to evaluate the effects of M13 phage along with RGD peptide motif on in vitro and in vivo vascularization. The obtained results demonstrated the increased cellular proliferation, HUVECs migration, cells altered morphology, and cells attachment to M13 phage-RGD coated surface. In addition, the expression of Vascular Endothelial Growth Factor A (VEGF-A), VEGF Receptors 2 and 3, Matrix Metalloproteinase 9 (MMP9), and epithelial nitric oxide synthase (eNOS) transcripts were significantly upregulated due to the HUVECs culturing on M13 phage-RGD coated surface. Furthermore, VEGF protein secretion, nitric oxide, and reactive oxygen species (ROS) production were significantly increased in cells cultured on M13 phage-RGD coated surface.
Collapse
Affiliation(s)
- Zohreh Safari
- Department of genetics, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, Iran
| | - Sara Soudi
- Department of Immunology, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran.
| | - Nazli Jafarzadeh
- Department of genetics, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, Iran
| | - Ahmad Zavaran Hosseini
- Department of Immunology, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - Elham Vojoudi
- Department of Regenerative Medicine, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Majid Sadeghizadeh
- Department of genetics, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, Iran.
| |
Collapse
|
22
|
Sarode DN, Roy S. In Vitro models for thrombogenicity testing of blood-recirculating medical devices. Expert Rev Med Devices 2019; 16:603-616. [PMID: 31154869 DOI: 10.1080/17434440.2019.1627199] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
INTRODUCTION Blood-recirculating medical devices, such as mechanical circulatory support (MCS), extracorporeal membrane oxygenators (ECMO), and hemodialyzers, are commonly used to treat or improve quality of life in patients with cardiac, pulmonary, and renal failure, respectively. As part of their regulatory approval, guidelines for thrombosis evaluation in pre-clinical development have been established. In vitro testing evaluates a device's potential to produce thrombosis markers in static and dynamic flow loops. AREAS COVERED This review focuses on in vitro static and dynamic models to assess thrombosis in blood-recirculating medical devices. A summary of key devices is followed by a review of molecular markers of contact activation. Current thrombosis testing guidance documents, ISO 10993-4, ASTM F-2888, and F-2382 will be discussed, followed by analysis of their application to in vitro testing models. EXPERT OPINION In general, researchers have favored in vivo models to thoroughly evaluate thrombosis, limiting in vitro evaluation to hemolysis. In vitro studies are not standardized and it is often difficult to compare studies on similar devices. As blood-recirculating devices have advanced to include wearable and implantable artificial organs, expanded guidelines standardizing in vitro testing are needed to identify the thrombotic potential without excessive use of in vivo resources during pre-clinical development.
Collapse
Affiliation(s)
- Deepika N Sarode
- a Department of Bioengineering and Therapeutic Sciences , University of California , San Francisco , CA , USA
| | - Shuvo Roy
- a Department of Bioengineering and Therapeutic Sciences , University of California , San Francisco , CA , USA
| |
Collapse
|
23
|
Lin S, Li X, Wang K, Shang T, Zhou L, Zhang L, Wang J, Huang N. An Albumin Biopassive Polyallylamine Film with Improved Blood Compatibility for Metal Devices. Polymers (Basel) 2019; 11:E734. [PMID: 31018520 PMCID: PMC6523212 DOI: 10.3390/polym11040734] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 04/16/2019] [Accepted: 04/20/2019] [Indexed: 11/17/2022] Open
Abstract
Nowadays, a variety of materials are employed to make numerous medical devices, including metals, polymers, ceramics, and others. Blood-contact devices are one of the major classes of these medical devices, and they have been widely applied in clinical settings. Blood-contact devices usually need to have good mechanical properties to maintain clinical performance. Metal materials are one desirable candidate to fabricate blood-contact devices due to their excellent mechanical properties and machinability, although the blood compatibility of existing blood-contact devices is better than other medical devices, such as artificial joints and artificial crystals. However, blood coagulation still occurs when these devices are used in clinical settings. Therefore, it is necessary to develop a new generation of blood-contact devices with fewer complications, and the key factor is to develop novel biomaterials with good blood compatibility. In this work, one albumin biopassive polyallylamine film was successfully established onto the 316L stainless steel (SS) surface. The polyallylamine film was prepared by plasma polymerization in the vacuum chamber, and then polyallylamine film was annealed at 150 °C for 1 h. The chemical compositions of the plasma polymerized polyallylamine film (PPAa) and the annealed polyallylamine film (HT-PPAa) were characterized by Fourier transform infrared spectrum (FTIR). Then, the wettability, surface topography, and thickness of the PPAa and HT-PPAa were also evaluated. HT-PPAa showed increased stability when compared with PPAa film. The major amino groups remained on the surface of HT-PPAa after annealing, indicating that this could be a good platform for numerous molecules' immobilization. Subsequently, the bovine serum albumin (BSA) was immobilized onto the HT-PPAa surface. The successful introduction of the BSA was confirmed by the FTIR and XPS detections. The blood compatibility of these modified films was evaluated by platelets adhesion and activation assays. The number of the platelets that adhered on BSA-modified HT-PPAa film was significantly decreased, and the activation degree of the adhered platelets was also decreased. These data revealed that the blood compatibility of the polyallylamine film was improved after BSA immobilized. This work provides a facile and effective approach to develop novel surface treatment for new-generation blood-contact devices with improved hemocompatibility.
Collapse
Affiliation(s)
- Shuang Lin
- Key Lab. of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China.
| | - Xin Li
- Key Lab. of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China.
| | - Kebing Wang
- Key Lab. of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China.
| | - Tengda Shang
- Key Lab. of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China.
| | - Lei Zhou
- Key Lab. of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China.
| | - Lu Zhang
- Key Lab. of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China.
| | - Jin Wang
- Key Lab. of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China.
| | - Nan Huang
- Key Lab. of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China.
| |
Collapse
|
24
|
Shen SC, Letchmanan K, Chow PS, Tan RBH. Antibiotic elution and mechanical property of TiO2 nanotubes functionalized PMMA-based bone cements. J Mech Behav Biomed Mater 2019; 91:91-98. [DOI: 10.1016/j.jmbbm.2018.11.020] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 11/16/2018] [Accepted: 11/19/2018] [Indexed: 11/26/2022]
|
25
|
Mukhopadhyay S, Veroniaina H, Chimombe T, Han L, Zhenghong W, Xiaole Q. Synthesis and compatibility evaluation of versatile mesoporous silica nanoparticles with red blood cells: an overview. RSC Adv 2019; 9:35566-35578. [PMID: 35528069 PMCID: PMC9074774 DOI: 10.1039/c9ra06127d] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Accepted: 09/18/2019] [Indexed: 12/20/2022] Open
Abstract
Protean mesoporous silica nanoparticles are propitious candidates over decades for nanoscale drug delivery systems due to their unique characteristics, including changeable pore size, mesoporosity, high drug loading capacity and biodegradability.
Collapse
Affiliation(s)
- Subhankar Mukhopadhyay
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| | | | - Tadious Chimombe
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| | - Lidong Han
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| | - Wu Zhenghong
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| | - Qi Xiaole
- Key Laboratory of Modern Chinese Medicines
- China Pharmaceutical University
- Nanjing 210009
- PR China
| |
Collapse
|
26
|
Lin Y, Shao Y, Li J, Zhang W, Zheng K, Zheng X, Huang X, Liao Z, Xie Y, He J. The hierarchical micro-/nanotextured topographies promote the proliferation and angiogenesis-related genes expression in human umbilical vein endothelial cells by initiation of Hedgehog-Gli1 signaling. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2018; 46:S1141-S1151. [PMID: 30453796 DOI: 10.1080/21691401.2018.1533845] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Yao Lin
- The Department of Stomatology, Jieyang Affiliated Hospital, SunYat-sen University, Jieyang, Guangdong, China
| | - Yiming Shao
- The Intensive Care Unit, Guangdong Key Laboratory of Age-Related Cardiac and Cerebral Diseases, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China
| | - Jieyin Li
- The Department of Stomatology, Jieyang Affiliated Hospital, SunYat-sen University, Jieyang, Guangdong, China
| | - Wenying Zhang
- The Intensive Care Unit, Guangdong Key Laboratory of Age-Related Cardiac and Cerebral Diseases, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China
| | - Kaibin Zheng
- The Department of Stomatology, Jieyang Affiliated Hospital, SunYat-sen University, Jieyang, Guangdong, China
| | - Xuying Zheng
- The Department of Stomatology, Jieyang Affiliated Hospital, SunYat-sen University, Jieyang, Guangdong, China
| | - Xiaoman Huang
- The Department of Stomatology, Jieyang Affiliated Hospital, SunYat-sen University, Jieyang, Guangdong, China
| | - Zipeng Liao
- The Department of Stomatology, Jieyang Affiliated Hospital, SunYat-sen University, Jieyang, Guangdong, China
| | - Yirui Xie
- The Department of Stomatology, Jieyang Affiliated Hospital, SunYat-sen University, Jieyang, Guangdong, China
| | - Junbing He
- The Intensive Care Unit, Jieyang Affiliated Hospital, SunYat-sen University, Jieyang, Guangdong, China
| |
Collapse
|
27
|
Application of TiO2
Nanotubes as a Drug Delivery System for Biomedical Implants: A Critical Overview. ChemistrySelect 2018. [DOI: 10.1002/slct.201801459] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
28
|
Weber M, Steinle H, Golombek S, Hann L, Schlensak C, Wendel HP, Avci-Adali M. Blood-Contacting Biomaterials: In Vitro Evaluation of the Hemocompatibility. Front Bioeng Biotechnol 2018; 6:99. [PMID: 30062094 PMCID: PMC6054932 DOI: 10.3389/fbioe.2018.00099] [Citation(s) in RCA: 321] [Impact Index Per Article: 53.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Accepted: 06/26/2018] [Indexed: 12/15/2022] Open
Abstract
Hemocompatibility of blood-contacting biomaterials is one of the most important criteria for their successful in vivo applicability. Thus, extensive in vitro analyses according to ISO 10993-4 are required prior to clinical applications. In this review, we summarize essential aspects regarding the evaluation of the hemocompatibility of biomaterials and the required in vitro analyses for determining the blood compatibility. Static, agitated, or shear flow models are used to perform hemocompatibility studies. Before and after the incubation of the test material with fresh human blood, hemolysis, cell counts, and the activation of platelets, leukocytes, coagulation and complement system are analyzed. Furthermore, the surface of biomaterials are evaluated concerning attachment of blood cells, adsorption of proteins, and generation of thrombus and fibrin networks.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Meltem Avci-Adali
- Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, Tübingen, Germany
| |
Collapse
|
29
|
Olmer R, Engels L, Usman A, Menke S, Malik MNH, Pessler F, Göhring G, Bornhorst D, Bolten S, Abdelilah-Seyfried S, Scheper T, Kempf H, Zweigerdt R, Martin U. Differentiation of Human Pluripotent Stem Cells into Functional Endothelial Cells in Scalable Suspension Culture. Stem Cell Reports 2018; 10:1657-1672. [PMID: 29681541 PMCID: PMC5995343 DOI: 10.1016/j.stemcr.2018.03.017] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 03/20/2018] [Accepted: 03/20/2018] [Indexed: 12/11/2022] Open
Abstract
Endothelial cells (ECs) are involved in a variety of cellular responses. As multifunctional components of vascular structures, endothelial (progenitor) cells have been utilized in cellular therapies and are required as an important cellular component of engineered tissue constructs and in vitro disease models. Although primary ECs from different sources are readily isolated and expanded, cell quantity and quality in terms of functionality and karyotype stability is limited. ECs derived from human induced pluripotent stem cells (hiPSCs) represent an alternative and potentially superior cell source, but traditional culture approaches and 2D differentiation protocols hardly allow for production of large cell numbers. Aiming at the production of ECs, we have developed a robust approach for efficient endothelial differentiation of hiPSCs in scalable suspension culture. The established protocol results in relevant numbers of ECs for regenerative approaches and industrial applications that show in vitro proliferation capacity and a high degree of chromosomal stability. Efficient generation of hiPSC-derived ECs in scalable suspension culture High degree of chromosomal stability of hiPSC-ECs after in vitro expansion Generation of relevant numbers of hiPSC-ECs for regenerative approaches
Collapse
Affiliation(s)
- Ruth Olmer
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiothoracic, Transplantation and Vascular Surgery (HTTG), Hannover Medical School, Carl-Neuberg-Str.1, 30625 Hannover, Germany; REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), 30625 Hannover, Germany
| | - Lena Engels
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiothoracic, Transplantation and Vascular Surgery (HTTG), Hannover Medical School, Carl-Neuberg-Str.1, 30625 Hannover, Germany; REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany
| | - Abdulai Usman
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiothoracic, Transplantation and Vascular Surgery (HTTG), Hannover Medical School, Carl-Neuberg-Str.1, 30625 Hannover, Germany; REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), 30625 Hannover, Germany
| | - Sandra Menke
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiothoracic, Transplantation and Vascular Surgery (HTTG), Hannover Medical School, Carl-Neuberg-Str.1, 30625 Hannover, Germany; REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), 30625 Hannover, Germany
| | - Muhammad Nasir Hayat Malik
- TWINCORE Centre for Experimental and Clinical Infection Research, 30625 Hannover, Germany; Helmholtz-Centre for Infection Research Braunschweig, 38124 Braunschweig, Germany; Centre for Individualised Infection Medicine, 30625 Hannover, Germany
| | - Frank Pessler
- TWINCORE Centre for Experimental and Clinical Infection Research, 30625 Hannover, Germany; Helmholtz-Centre for Infection Research Braunschweig, 38124 Braunschweig, Germany; Centre for Individualised Infection Medicine, 30625 Hannover, Germany
| | - Gudrun Göhring
- Institute of Cell and Molecular Pathology, Hannover Medical School, 30625 Hannover, Germany
| | - Dorothee Bornhorst
- REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany; Institute of Molecular Biology, Hannover Medical School, 30625 Hannover, Germany
| | - Svenja Bolten
- REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany; Institute of Biochemistry and Biology, Potsdam University, Karl-Liebknecht-Straße 24-25, 14476 Potsdam, Germany
| | - Salim Abdelilah-Seyfried
- Institute of Molecular Biology, Hannover Medical School, 30625 Hannover, Germany; Institute of Biochemistry and Biology, Potsdam University, Karl-Liebknecht-Straße 24-25, 14476 Potsdam, Germany
| | - Thomas Scheper
- REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany; Institute for Technical Chemistry, Leibniz University Hannover, 30167 Hannover, Germany
| | - Henning Kempf
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiothoracic, Transplantation and Vascular Surgery (HTTG), Hannover Medical School, Carl-Neuberg-Str.1, 30625 Hannover, Germany; REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany
| | - Robert Zweigerdt
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiothoracic, Transplantation and Vascular Surgery (HTTG), Hannover Medical School, Carl-Neuberg-Str.1, 30625 Hannover, Germany; REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany
| | - Ulrich Martin
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiothoracic, Transplantation and Vascular Surgery (HTTG), Hannover Medical School, Carl-Neuberg-Str.1, 30625 Hannover, Germany; REBIRTH-Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), 30625 Hannover, Germany.
| |
Collapse
|
30
|
Bagheri M, Mohammadi M, Steele TW, Ramezani M. Nanomaterial coatings applied on stent surfaces. Nanomedicine (Lond) 2017; 11:1309-26. [PMID: 27111467 DOI: 10.2217/nnm-2015-0007] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
The advent of percutaneous coronary intervention and intravascular stents has revolutionized the field of interventional cardiology. Nonetheless, in-stent restenosis, inflammation and late-stent thrombosis are the major obstacles with currently available stents. In order to enhance the hemocompatibility of stents, advances in the field of nanotechnology allow novel designs of nanoparticles and biomaterials toward localized drug/gene carriers or stent scaffolds. The current review focuses on promising polymers used in the fabrication of newer generations of stents with a short synopsis on atherosclerosis and current commercialized stents, nanotechnology's impact on stent development and recent advancements in stent biomaterials is discussed in context.
Collapse
Affiliation(s)
- Mahsa Bagheri
- Shariati Hospital, Mashhad University of Medical Sciences, Mashhad, PO Box 935189-9983, Iran.,Nanotechnology Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, PO Box 91775-1365, Iran
| | - Marzieh Mohammadi
- Nanotechnology Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, PO Box 91775-1365, Iran
| | - Terry Wj Steele
- Division of Materials Technology, Materials & Science Engineering, Nanyang Technological University, Singapore
| | - Mohammad Ramezani
- Pharmaceutical Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, PO Box 91775-1365, Iran
| |
Collapse
|
31
|
Skoog SA, Kumar G, Narayan RJ, Goering PL. Biological responses to immobilized microscale and nanoscale surface topographies. Pharmacol Ther 2017; 182:33-55. [PMID: 28720431 DOI: 10.1016/j.pharmthera.2017.07.009] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Cellular responses are highly influenced by biochemical and biomechanical interactions with the extracellular matrix (ECM). Due to the impact of ECM architecture on cellular responses, significant research has been dedicated towards developing biomaterials that mimic the physiological environment for design of improved medical devices and tissue engineering scaffolds. Surface topographies with microscale and nanoscale features have demonstrated an effect on numerous cellular responses, including cell adhesion, migration, proliferation, gene expression, protein production, and differentiation; however, relationships between biological responses and surface topographies are difficult to establish due to differences in cell types and biomaterial surface properties. Therefore, it is important to optimize implant surface feature characteristics to elicit desirable biological responses for specific applications. The goal of this work was to review studies investigating the effects of microstructured and nanostructured biomaterials on in vitro biological responses through fabrication of microscale and nanoscale surface topographies, physico-chemical characterization of material surface properties, investigation of protein adsorption dynamics, and evaluation of cellular responses in specific biomedical applications.
Collapse
Affiliation(s)
- Shelby A Skoog
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States; Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Raleigh, NC, United States
| | - Girish Kumar
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States
| | - Roger J Narayan
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Raleigh, NC, United States
| | - Peter L Goering
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States.
| |
Collapse
|
32
|
Puppi D, Pirosa A, Lupi G, Erba PA, Giachi G, Chiellini F. Design and fabrication of novel polymeric biodegradable stents for small caliber blood vessels by computer-aided wet-spinning. ACTA ACUST UNITED AC 2017; 12:035011. [PMID: 28589916 DOI: 10.1088/1748-605x/aa6a28] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Biodegradable stents have emerged as one of the most promising approaches in obstructive cardiovascular disease treatment due to their potential in providing mechanical support while it is needed and then leaving behind only the healed natural vessel. The aim of this study was to develop polymeric biodegradable stents for application in small caliber blood vessels. Poly[(R)-3-hydroxybutyrate-co-(R)-3-hydroxyhexanoate] (PHBHHx), a renewable microbial aliphatic polyester, and poly(ε-caprolactone), a synthetic polyester approved by the US Food and Drug Administration for different biomedical applications, were investigated as suitable polymers for stent development. A novel manufacturing approach based on computer-aided wet-spinning of a polymeric solution was developed to fabricate polymeric stents. By tuning the fabrication parameters, it was possible to develop stents with different morphological characteristics (e.g. pore size and wall thickness). Thermal analysis results suggested that material processing did not cause changes in the molecular structure of the polymers. PHBHHx stents demonstrated great radial elasticity while PCL stents showed higher axial and radial mechanical strength. The developed stents resulted able to sustain proliferation of human umbilical vein endothelial cells within two weeks of in vitro culture and they showed excellent results in terms of thromboresistivity when in contact with human blood.
Collapse
Affiliation(s)
- D Puppi
- BIOLab Research Group, Department of Chemistry and Industrial Chemistry, University of Pisa, UdR INSTM Pisa, via Moruzzi 13, I-56124, Pisa, Italy
| | | | | | | | | | | |
Collapse
|
33
|
|
34
|
Pflaum M, Kühn-Kauffeldt M, Schmeckebier S, Dipresa D, Chauhan K, Wiegmann B, Haug RJ, Schein J, Haverich A, Korossis S. Endothelialization and characterization of titanium dioxide-coated gas-exchange membranes for application in the bioartificial lung. Acta Biomater 2017; 50:510-521. [PMID: 27956361 DOI: 10.1016/j.actbio.2016.12.017] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Revised: 12/05/2016] [Accepted: 12/07/2016] [Indexed: 01/02/2023]
Abstract
Fouling on the gas-exchange hollow-fiber membrane (HFM) of extracorporeal membrane oxygenation (ECMO) devices by blood components and pathogens represents the major hurdle to their long-term application in patients with lung deficiency or unstable hemodynamics. Although patients are treated with anticoagulants, deposition of blood proteins onto the membrane surface may still occur after few days, leading to insufficient gas transfer and, consequently, to device failure. The aim of this study was to establish an endothelial cell (EC) monolayer onto the gas-exchange membrane of an ECMO device with a view to developing a hemocompatible bioartificial lung. Poly(4-methyl-1-pentene) (PMP) gas-exchange membranes were coated with titanium dioxide (TiO2), using the pulsed vacuum cathodic arc plasma deposition (PVCAPD) technique, in order to generate a stable interlayer, enabling cell adhesion onto the strongly hydrophobic PMP membrane. The TiO2 coating reduced the oxygen transfer rate (OTR) of the membrane by 22%, and it successfully mediated EC attachment. The adhered ECs formed a confluent monolayer, which retained a non-thrombogenic state and showed cell-to-cell, as well as cell-to-substrate contacts. The established monolayer was able to withstand physiological shear stress and possessed a "self-healing" capacity at areas of induced monolayer disruption. The study demonstrated that the TiO2 coating mediated EC attachment and the establishment of a functional EC monolayer. STATEMENT OF SIGNIFICANCE Surface endothelialization is considered an effective approach to achieve complete hamocompatibility of blood-contacting devices. Several strategies to enable endothelial cell adhesion onto stents and vascular prostheses have already been described in the literature. However, only few studies investigated the feasibility of establishing an endothelial monolayer onto the gas exchange membrane of ECMO devices, using peptides or proteins that were weakly adsorbed via dip coating techniques. This study demonstrated the effectiveness of an alternative and stable titanium dioxide coating for gas-exchange membranes, which enabled the establishment of a confluent, functional and non-activated endothelial monolayer, while maintaining oxygen permeability.
Collapse
|
35
|
Li M, Xu X, Jia Z, Shi Y, Cheng Y, Zheng Y. Rapamycin-loaded nanoporous α-Fe 2O 3 as an endothelial favorable and thromboresistant coating for biodegradable drug-eluting Fe stent applications. J Mater Chem B 2017; 5:1182-1194. [PMID: 32263589 DOI: 10.1039/c6tb02634f] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Iron and its alloys can be potentially employed to fabricate advanced degradable cardiovascular stents due to their excellent mechanical and biocompatibility properties. However, their clinical applications are hindered by their inherent slow degradation rate, the formation of thrombosis and in-stent restenosis. In this study, vertically oriented and orderly arranged α-Fe2O3 (hematite) nanotubes with diameters ranging from 30 nm to 70 nm were successfully fabricated on iron substrates using an anodic oxidation approach. These nanotubular coatings acted as drug depots by being loaded with anti-proliferation drug rapamycin to accelerate the re-endothelialization process and being coated by PLGA through a simple spin-coating process to control the drug release rate. The static immersion test showed that the 50 nm-Fe2O3 nanotube arrays displayed a faster corrosion rate than pristine Fe, and the PLGA coating effectively reduced the initial burst release of the loaded drug and extended the rapamycin release time to 30 days. The CCK-8 assay and immunofluorescence staining analysis results indicated that the endothelial cells (ECs) on the coated samples showed higher cell viability than the vascular smooth muscle cells (VSMCs), with possible outcomes to promote re-endothelialization and decrease VSMC proliferation. In addition, the surface modified iron exhibited very good hemocompatibility. The current findings suggested that fabricating rapamycin-loaded and PLGA coated Fe2O3 nanotubes on a pure iron surface may be a promising method to improve the corrosion rate and accelerate the re-endothelialization of the iron for biodegradable cardiovascular stent applications.
Collapse
Affiliation(s)
- Ming Li
- Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China.
| | | | | | | | | | | |
Collapse
|
36
|
Junkar I, Kulkarni M, Humpolíček P, Capáková Z, Burja B, Mazare A, Schmuki P, Mrak-Poljšak K, Flašker A, Žigon P, Čučnik S, Mozetič M, Tomšič M, Iglič A, Sodin-Semrl S. Could Titanium Dioxide Nanotubes Represent a Viable Support System for Appropriate Cells in Vascular Implants? ADVANCES IN BIOMEMBRANES AND LIPID SELF-ASSEMBLY 2017. [DOI: 10.1016/bs.abl.2016.12.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
37
|
Zhang S, Huang J, Tang Y, Li S, Ge M, Chen Z, Zhang K, Lai Y. Understanding the Role of Dynamic Wettability for Condensate Microdrop Self-Propelling Based on Designed Superhydrophobic TiO 2 Nanostructures. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2017; 13. [PMID: 27152963 DOI: 10.1002/smll.201600687] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Revised: 03/29/2016] [Indexed: 05/06/2023]
Abstract
The ability to release the adhered drops on superhydrophobic surfaces is very important for self-cleaning, antifrosting/icing, microfluidic device, and heat transfer applications. In this paper, three types of in situ electrochemical anodizing TiO2 nanostructure films are rationally designed and fabricated on titanium substrates with special superwettability, viz., TiO2 nanotube arrays, irregular TiO2 nanotube arrays, and hierarchical TiO2 particle arrays (HTPA), and their corresponding behavior in condensate microdrop self-propelling (CMDSP) is investigated. Compared to the flat titanium counterpart, all three types of rough TiO2 samples demonstrate a uniform distribution of smaller microscale droplets. Among the treated surfaces, the HTPA possesses the highest condensate density, and more than 80% of the droplets possess a diameter below 10 μm. Theoretical analysis indicates that the feature is mainly due to the morphology and structure induced extremely low droplet adhesion on super-antiwetting TiO2 hierarchical surfaces, where the excess surface energy released from the migration leads to the self-propelling of merged microdrop. This work offers a way to rationally construct CMDSP surfaces with excellent self-cleaning, antifrosting/icing ability, and enhanced condensation heat transfer efficiency.
Collapse
Affiliation(s)
- Songnan Zhang
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, P. R. China
| | - Jianying Huang
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, P. R. China
| | - Yuxin Tang
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Shuhui Li
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, P. R. China
| | - Mingzheng Ge
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, P. R. China
| | - Zhong Chen
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Keqin Zhang
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, P. R. China
| | - Yuekun Lai
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou, 215123, P. R. China
| |
Collapse
|
38
|
Skoog SA, Lu Q, Malinauskas RA, Sumant AV, Zheng J, Goering PL, Narayan RJ, Casey BJ. Effects of nanotopography on the in vitro hemocompatibility of nanocrystalline diamond coatings. J Biomed Mater Res A 2016; 105:253-264. [PMID: 27543370 DOI: 10.1002/jbm.a.35872] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Revised: 07/29/2016] [Accepted: 08/18/2016] [Indexed: 01/14/2023]
Abstract
Nanocrystalline diamond (NCD) coatings have been investigated for improved wear resistance and enhanced hemocompatibility of cardiovascular devices. The goal of this study was to evaluate the effects of NCD surface nanotopography on in vitro hemocompatibility. NCD coatings with small (NCD-S) and large (NCD-L) grain sizes were deposited using microwave plasma chemical vapor deposition and characterized using scanning electron microscopy, atomic force microscopy, contact angle testing, and Raman spectroscopy. NCD-S coatings exhibited average grain sizes of 50-80 nm (RMS 5.8 nm), while NCD-L coatings exhibited average grain sizes of 200-280 nm (RMS 23.1 nm). In vitro hemocompatibility testing using human blood included protein adsorption, hemolysis, nonactivated partial thromboplastin time, platelet adhesion, and platelet activation. Both NCD coatings demonstrated low protein adsorption, a nonhemolytic response, and minimal activation of the plasma coagulation cascade. Furthermore, the NCD coatings exhibited low thrombogenicity with minimal platelet adhesion and aggregation, and similar morphological changes to surface-bound platelets (i.e., activation) in comparison to the HDPE negative control material. For all assays, there were no significant differences in the blood-material interactions of NCD-S versus NCD-L. The two tested NCD coatings, regardless of nanotopography, had similar hemocompatibility profiles compared to the negative control material (HDPE) and should be further evaluated for use in blood-contacting medical devices. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 253-264, 2017.
Collapse
Affiliation(s)
- Shelby A Skoog
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Raleigh, North Carolina.,Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland
| | - Qijin Lu
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland
| | - Richard A Malinauskas
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland
| | - Anirudha V Sumant
- Center for Nanoscale Materials, Argonne National Laboratory, Argonne, Illinois
| | - Jiwen Zheng
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland
| | - Peter L Goering
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland
| | - Roger J Narayan
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Raleigh, North Carolina
| | - Brendan J Casey
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland
| |
Collapse
|
39
|
Wang Q, Huang JY, Li HQ, Chen Z, Zhao AZJ, Wang Y, Zhang KQ, Sun HT, Al-Deyab SS, Lai YK. TiO 2 nanotube platforms for smart drug delivery: a review. Int J Nanomedicine 2016; 11:4819-4834. [PMID: 27703349 PMCID: PMC5036548 DOI: 10.2147/ijn.s108847] [Citation(s) in RCA: 75] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Titania nanotube (TNT) arrays are recognized as promising materials for localized drug delivery implants because of their excellent properties and facile preparation process. This review highlights the concept of localized drug delivery systems based on TNTs, considering their outstanding biocompatibility in a series of ex vivo and in vivo studies. Considering the safety of TNT implants in the host body, studies of the biocompatibility present significant importance for the clinical application of TNT implants. Toward smart TNT platforms for sustainable drug delivery, several advanced approaches were presented in this review, including controlled release triggered by temperature, light, radiofrequency magnetism, and ultrasonic stimulation. Moreover, TNT implants used in medical therapy have been demonstrated by various examples including dentistry, orthopedic implants, cardiovascular stents, and so on. Finally, a future perspective of TNTs for clinical applications is provided.
Collapse
Affiliation(s)
- Qun Wang
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou
- College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, People’s Republic of China
| | - Jian-Ying Huang
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou
| | - Hua-Qiong Li
- Wenzhou Institute of Biomaterials and Engineering, Chinese Academy of Sciences, Wenzhou, People’s Republic of China
| | - Zhong Chen
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, Singapore
| | - Allan Zi-Jian Zhao
- Wenzhou Institute of Biomaterials and Engineering, Chinese Academy of Sciences, Wenzhou, People’s Republic of China
| | - Yi Wang
- Wenzhou Institute of Biomaterials and Engineering, Chinese Academy of Sciences, Wenzhou, People’s Republic of China
| | - Ke-Qin Zhang
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou
| | - Hong-Tao Sun
- College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, People’s Republic of China
| | - Salem S Al-Deyab
- Department of Chemistry, College of Science, King Saud University, Riyadh, Saudi Arabia
| | - Yue-Kun Lai
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou
| |
Collapse
|
40
|
Nandakumar D, Bendavid A, Martin PJ, Harris KD, Ruys AJ, Lord MS. Fabrication of Semiordered Nanopatterned Diamond-like Carbon and Titania Films for Blood Contacting Applications. ACS APPLIED MATERIALS & INTERFACES 2016; 8:6802-6810. [PMID: 26928086 DOI: 10.1021/acsami.5b11614] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Biomaterials with the ability to interface with, but not activate, blood components are essential for a multitude of medical devices. Diamond-like carbon (DLC) and titania (TiO2) have shown promise for these applications; however, both support platelet adhesion and activation. This study explored the fabrication of nanostructured DLC and TiO2 thin film coatings using a block copolymer deposition technique that produced semiordered nanopatterns with low surface roughness (5-8 nm Rrms). These surfaces supported fibrinogen and plasma protein adsorption that predominantly adsorbed between the nanofeatures and reduced the overall surface roughness. The conformation of the adsorbed fibrinogen was altered on the nanopatterned surfaces as compared with the planar surfaces to reveal higher levels of the platelet binding region. Planar DLC and TiO2 coatings supported less platelet adhesion than nanopatterned DLC and TiO2. However, platelets on the nanopatterned DLC coatings were less spread indicating a lower level of platelet activation on the nanostructured DLC coatings compared with the planar DLC coatings. These data indicated that nanostructured DLC coatings may find application in blood contacting medical devices in the future.
Collapse
Affiliation(s)
- Deepika Nandakumar
- Biomedical Engineering, School of AMME, University of Sydney , Sydney, New South Wales 2007, Australia
| | - Avi Bendavid
- Material Science and Engineering, CSIRO , Lindfield, New South Wales 2070, Australia
| | - Philip J Martin
- Material Science and Engineering, CSIRO , Lindfield, New South Wales 2070, Australia
| | - Kenneth D Harris
- National Institute for Nanotechnology, National Research Council , Edmonton, Alberta T5B 0N1, Canada
| | - Andrew J Ruys
- Biomedical Engineering, School of AMME, University of Sydney , Sydney, New South Wales 2007, Australia
| | - Megan S Lord
- Graduate School of Biomedical Engineering, University of New South Wales , Sydney, New South Wales 2052, Australia
| |
Collapse
|
41
|
Tan AW, Liau LL, Chua KH, Ahmad R, Akbar SA, Pingguan-Murphy B. Enhanced in vitro angiogenic behaviour of human umbilical vein endothelial cells on thermally oxidized TiO2 nanofibrous surfaces. Sci Rep 2016; 6:21828. [PMID: 26883761 PMCID: PMC4756327 DOI: 10.1038/srep21828] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2015] [Accepted: 02/02/2016] [Indexed: 02/08/2023] Open
Abstract
One of the major challenges in bone grafting is the lack of sufficient bone vascularization. A rapid and stable bone vascularization at an early stage of implantation is essential for optimal functioning of the bone graft. To address this, the ability of in situ TiO2 nanofibrous surfaces fabricated via thermal oxidation method to enhance the angiogenic potential of human umbilical vein endothelial cells (HUVECs) was investigated. The cellular responses of HUVECs on TiO2 nanofibrous surfaces were studied through cell adhesion, cell proliferation, capillary-like tube formation, growth factors secretion (VEGF and BFGF), and angiogenic-endogenic-associated gene (VEGF, VEGFR2, BFGF, PGF, HGF, Ang-1, VWF, PECAM-1 and ENOS) expression analysis after 2 weeks of cell seeding. Our results show that TiO2 nanofibrous surfaces significantly enhanced adhesion, proliferation, formation of capillary-like tube networks and growth factors secretion of HUVECs, as well as leading to higher expression level of all angiogenic-endogenic-associated genes, in comparison to unmodified control surfaces. These beneficial effects suggest the potential use of such surface nanostructures to be utilized as an advantageous interface for bone grafts as they can promote angiogenesis, which improves bone vascularization.
Collapse
Affiliation(s)
- Ai Wen Tan
- Department of Biomedical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Ling Ling Liau
- Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| | - Kien Hui Chua
- Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| | - Roslina Ahmad
- Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Sheikh Ali Akbar
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| | | |
Collapse
|
42
|
Junkar I, Kulkarni M, Drašler B, Rugelj N, Mazare A, Flašker A, Drobne D, Humpolíček P, Resnik M, Schmuki P, Mozetič M, Iglič A. Influence of various sterilization procedures on TiO2 nanotubes used for biomedical devices. Bioelectrochemistry 2016; 109:79-86. [PMID: 26900885 DOI: 10.1016/j.bioelechem.2016.02.001] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Revised: 02/04/2016] [Accepted: 02/07/2016] [Indexed: 01/12/2023]
Abstract
Sterilization is the final surface treatment procedure of all implantable devices and is one of the key factors which have to be considered before implementation. Since different sterilization procedures for all implantable devices influence mechanical properties as well as biological response, the influence of different sterilization techniques on titanium nanotubes was studied. Commonly used sterilization techniques such as autoclaving, ultra-violet light sterilization, hydrogen peroxide plasma sterilization as well as the not so frequently used gaseous oxygen plasma sterilization were used. Three different nanotube diameters; 15 nm, 50 nm and 100 nm were employed to study the effects of various sterilization techniques. It was observed that autoclave sterilization resulted in destruction of nanotubular features on all three studied nanotube diameters, while UV-light and both kinds of plasma sterilization did not cause any significant morphological changes on the surfaces. Differences between the sterilization techniques employed influenced cytocompatibility, especially in the case of nanotubes with 100 nm diameter.
Collapse
Affiliation(s)
- Ita Junkar
- Jožef Stefan Institute, Jamova cesta 39, Ljubljana SI-1000, Slovenia.
| | - Mukta Kulkarni
- Laboratory of Biophysics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana SI-1000, Slovenia
| | - Barbara Drašler
- Department of Biology, Biotechnical Faculty, University of Ljubljana, Večna pot 111, 1000 Ljubljana, Slovenia
| | - Neža Rugelj
- Department of Biology, Biotechnical Faculty, University of Ljubljana, Večna pot 111, 1000 Ljubljana, Slovenia
| | - Anca Mazare
- Department of Materials Science and Engineering, WW4-LKO, University of Erlangen Nuremberg, Martensstr. 7, 91058 Erlangen, Germany
| | - Ajda Flašker
- Laboratory of Biophysics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana SI-1000, Slovenia
| | - Damjana Drobne
- Department of Biology, Biotechnical Faculty, University of Ljubljana, Večna pot 111, 1000 Ljubljana, Slovenia
| | - Petr Humpolíček
- Centre of Polymer Systems, University Institute, Tomas Bata University in Zlin, Nad Ovcirnou 3685, 760 01 Zlin, Czech Republic
| | - Matic Resnik
- Jožef Stefan Institute, Jamova cesta 39, Ljubljana SI-1000, Slovenia
| | - Patrik Schmuki
- Department of Materials Science and Engineering, WW4-LKO, University of Erlangen Nuremberg, Martensstr. 7, 91058 Erlangen, Germany
| | - Miran Mozetič
- Jožef Stefan Institute, Jamova cesta 39, Ljubljana SI-1000, Slovenia
| | - Aleš Iglič
- Laboratory of Biophysics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana SI-1000, Slovenia
| |
Collapse
|
43
|
Wu XJ, Tang EK, Xu CQ, Yuan ZX. Hemocompatibility evaluation for peptide fragments of human serum albumin cleaved by cyanogens bromide. J Biomater Appl 2015; 30:974-82. [PMID: 26482572 DOI: 10.1177/0885328215608018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
We have previously demonstrated that peptide fragments of human serum albumin can be developed into potential renal targeting drug carriers. However, the interactions of these peptide fragments with red blood cells and plasma components are not evaluated well and there is yet no report on the evaluation of the hemocompatibility of peptide fragments. In this study, three kinds of peptide fragments were prepared and identified by amino acid analysis, and the blood compatibility of the peptide fragments was investigated by measuring blood coagulation, platelet and complement activation and hemolysis activity. Results indicated that all the peptide fragments prepared were highly hemocompatible without causing any clot formation, red blood cell aggregation or immune response. In addition, data from the cytotoxicity assay using HeLa cells and Madin-Darby canine kidney cells suggested that these peptide fragments do not induce toxicity towards either cell lines at concentrations up to 5 mg/ml. Therefore, it can be concluded that peptide fragments exhibit good hemocompatibility with no unwanted effect on the viability of renal cells, preliminarily demonstrating that it is safe to use peptide fragments as renal targeting drug carriers.
Collapse
Affiliation(s)
- Xiao-juan Wu
- Integrative Traditional and Western Medicine Hospital of Sichuan Province, Chengdu, Sichuan, China
| | - Edith Kai Tang
- Pharmacy, School of Medicine and Pharmacology, the University of Western Australia, Western Australia, Australia
| | - Chao-qun Xu
- Institute of Pharmacy, Sichuan Academy of Chinese Medicine Sciences, Chengdu, Sichuan, China
| | - Zhi-xiang Yuan
- Institute of Pharmacy, Sichuan Academy of Chinese Medicine Sciences, Chengdu, Sichuan, China
| |
Collapse
|
44
|
Ungureanu C, Dumitriu C, Popescu S, Enculescu M, Tofan V, Popescu M, Pirvu C. Enhancing antimicrobial activity of TiO2/Ti by torularhodin bioinspired surface modification. Bioelectrochemistry 2015; 107:14-24. [PMID: 26414412 DOI: 10.1016/j.bioelechem.2015.09.001] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2015] [Revised: 09/14/2015] [Accepted: 09/14/2015] [Indexed: 01/06/2023]
Abstract
Implant-associated infections are a major cause of morbidity and mortality. This study was performed using titanium samples coated by anodization with a titanium dioxide (TiO2) shielded nanotube layer. TiO2/Ti surface was modified by simple immersion in torularhodin solution and by using a mussel-inspired method based on polydopamine as bio adhesive for torularhodin immobilization. SEM analysis revealed tubular microstructures of torularhodin and the PDA ability to function as a catchy anchor between torularhodin and TiO2 surface. Corrosion resistance was associated with TiO2 barrier oxide layer and nano-organized oxide layer and the torularhodin surface modification does not bring significant changes in resistance of the oxide layer. Our results demonstrated that the torularhodin modified TiO2/Ti surface could effectively prevent adhesion and proliferation of Escherichia coli, Staphylococcus aureus, Enterococcus faecalis, Bacillus subtilis, and Pseudomonas aeruginosa. The new modified titanium surface showed good biocompatibility and well-behaved haemocompatibility. This biomaterial with enhanced antimicrobial activity holds great potential for future biomedical applications.
Collapse
Affiliation(s)
- Camelia Ungureanu
- University Politehnica of Bucharest, 313 Splaiul Independentei, Sector 6, Bucharest 060042, Romania
| | - Cristina Dumitriu
- University Politehnica of Bucharest, 313 Splaiul Independentei, Sector 6, Bucharest 060042, Romania
| | - Simona Popescu
- University Politehnica of Bucharest, 313 Splaiul Independentei, Sector 6, Bucharest 060042, Romania
| | - Monica Enculescu
- National Institute of Materials Physics, Atomistilor 105 bis, P.O. Box MG-7, Magurele, Bucharest 77125, Romania
| | - Vlad Tofan
- "Cantacuzino" National Institute of Research-Development for Microbiology and Immunology, 103 Splaiul Independentei, Sector 5, Bucharest 050096, Romania
| | - Marian Popescu
- National Institute for Research and Development in Microtechnologies, 126A, Erou Iancu Nicolae Street, Bucharest 077190, Romania
| | - Cristian Pirvu
- University Politehnica of Bucharest, 313 Splaiul Independentei, Sector 6, Bucharest 060042, Romania.
| |
Collapse
|
45
|
Milleret V, Buzzi S, Gehrig P, Ziogas A, Grossmann J, Schilcher K, Zinkernagel AS, Zucker A, Ehrbar M. Protein adsorption steers blood contact activation on engineered cobalt chromium alloy oxide layers. Acta Biomater 2015; 24:343-51. [PMID: 26102336 DOI: 10.1016/j.actbio.2015.06.020] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2015] [Revised: 06/12/2015] [Accepted: 06/16/2015] [Indexed: 12/01/2022]
Abstract
Biomaterials upon implantation are immediately covered by blood proteins which direct the subsequent blood activation. These early events determine the following cascade of biological reactions and consequently the long-term success of implants. The ability to modulate surface properties of biomaterials is therefore of considerable clinical significance. Goal of this study was an in-depth understanding of the biological response to cobalt chromium stent alloys with engineered surface oxide layers, which showed altered body reactions in vivo. We analyzed in vitro the biological events following initial blood contact on engineered cobalt chromium surfaces featuring said oxide layers. Surface-specific blood reactions were confirmed by scanning electron microscopy and the adsorbed protein layers were characterized by mass spectrometry. This powerful proteomics tool allowed the identification and quantification of over hundred surface-adhering proteins. Proteins associated with the coagulation cascade, platelet adhesion and neutrophil function correlated with the various blood surface activations observed. Furthermore, results of pre-coated surfaces with defined fibrinogen-albumin mixtures suggest that neutrophil adhesion was controlled by fibrinogen orientation and conformation rather than quantity. This study highlights the importance of controlling the biological response in the complex protein-implant surface interactions and the potential of the surface modifications to improve the clinical performance of medical implants. STATEMENT OF SIGNIFICANCE The blood contact activation of CoCr alloys is determined by their surface oxide layer properties. Modifications of the oxide layer affected the total amount of adsorbed proteins and the composition of the adsorbed protein layer. Additionally fibrinogen coatings mediated the surface-dependent neutrophil adhesion in a concentration-independent manner, indicating the influence of conformation and/or orientation of the adsorbed protein. Despite the complexity of protein-implant interactions, this study highlights the importance of understanding and controlling mechanisms of protein adhesion in order to improve and steer the performance of medical implants. It shows that modification of the surface oxide layer is a very attractive strategy to directly functionalize metallic implant surfaces and optimize their blood interaction for the desired orthopedic or cardiovascular applications.
Collapse
Affiliation(s)
- Vincent Milleret
- Department of Obstetrics, University Hospital Zurich, University of Zurich, Switzerland
| | | | - Peter Gehrig
- Functional Genomics Center Zurich, University of Zurich/ETH Zurich, Switzerland
| | - Algirdas Ziogas
- Department of Obstetrics, University Hospital Zurich, University of Zurich, Switzerland
| | - Jonas Grossmann
- Functional Genomics Center Zurich, University of Zurich/ETH Zurich, Switzerland
| | - Katrin Schilcher
- Division of Infectious Diseases and Hospital Epidemiology, University of Zurich, Switzerland
| | - Annelies S Zinkernagel
- Division of Infectious Diseases and Hospital Epidemiology, University of Zurich, Switzerland
| | | | - Martin Ehrbar
- Department of Obstetrics, University Hospital Zurich, University of Zurich, Switzerland.
| |
Collapse
|
46
|
Blood coagulation and platelet adhesion on polyaniline films. Colloids Surf B Biointerfaces 2015; 133:278-85. [DOI: 10.1016/j.colsurfb.2015.06.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2015] [Revised: 06/01/2015] [Accepted: 06/03/2015] [Indexed: 11/21/2022]
|
47
|
Hu T, Yang J, Cui K, Rao Q, Yin T, Tan L, Zhang Y, Li Z, Wang G. Controlled Slow-Release Drug-Eluting Stents for the Prevention of Coronary Restenosis: Recent Progress and Future Prospects. ACS APPLIED MATERIALS & INTERFACES 2015; 7:11695-11712. [PMID: 26011753 DOI: 10.1021/acsami.5b01993] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Drug-eluting stents (DES) have become more widely used by cardiologists than bare metal stents (BMS) because of their better ability to control restenosis. However, recognized negative events, particularly including delayed or incomplete endothelialization and late stent thrombosis, have caused concerns over the long-term safety of DES. Although stent-based drug delivery can facilitate a drug's release directly to the restenosis site, a burst of drug release can seriously affect the pharmacological action and is a major factor accounting for adverse effects. Therefore, the drug release rate has become an important criterion in evaluating DES. The factors affecting the drug release rate include the drug carrier, drug, coating methods, drug storage, elution direction, coating thickness, pore size in the coating, release conditions (release medium, pH value, temperature), and hemodynamics after the stent implantation. A better understanding of how these factors influence drug release is particularly important for the reasonable use of efficient control strategies for drug release. This review summarizes the factors influencing the drug release from DES and presents strategies for enhancing the control of the drug's release, including the stent design, the application of absorbable stents, the development of new polymers, and the application of nanocarriers and improvements in the coating technology. Therefore, this paper provides a reference for the preparation of novel controlled slow-release DES.
Collapse
Affiliation(s)
- Tingzhang Hu
- †Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory for Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Jiali Yang
- †Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory for Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Kun Cui
- ‡Center of Cardiology, Chongqing Zhongshan Hospital, Chongqing 400013, China
| | - Qiong Rao
- †Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory for Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Tieying Yin
- †Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory for Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Lili Tan
- †Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory for Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Yuan Zhang
- ‡Center of Cardiology, Chongqing Zhongshan Hospital, Chongqing 400013, China
| | - Zhenggong Li
- ‡Center of Cardiology, Chongqing Zhongshan Hospital, Chongqing 400013, China
| | - Guixue Wang
- †Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory for Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing 400030, China
| |
Collapse
|
48
|
Qiu KJ, Liu Y, Zhou FY, Wang BL, Li L, Zheng YF, Liu YH. Microstructure, mechanical properties, castability and in vitro biocompatibility of Ti-Bi alloys developed for dental applications. Acta Biomater 2015; 15:254-65. [PMID: 25595472 DOI: 10.1016/j.actbio.2015.01.009] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2014] [Revised: 12/19/2014] [Accepted: 01/02/2015] [Indexed: 12/30/2022]
Abstract
In this study, the microstructure, mechanical properties, castability, electrochemical behaviors, cytotoxicity and hemocompatibility of Ti-Bi alloys with pure Ti as control were systematically investigated to assess their potential applications in the dental field. The experimental results showed that, except for the Ti-20Bi alloy, the microstructure of all other Ti-Bi alloys exhibit single α-Ti phase, while Ti-20Bi alloy is consisted of mainly α-Ti phase and a small amount of BiTi2 and BiTi3 phases. The tensile strength, hardness and wear resistance of Ti-Bi alloys were demonstrated to be improved monotonically with the increase of Bi content. The castability test showed that Ti-2Bi alloy increased the castability of pure Ti by 11.7%. The studied Ti-Bi alloys showed better corrosion resistance than pure Ti in both AS (artificial saliva) and ASFL (AS containing 0.2% NaF and 0.3% lactic acid) solutions. The concentrations of both Ti ion and Bi ion released from Ti-Bi alloys are extremely low in AS, ASF (AS containing 0.2% NaF) and ASL (AS containing 0.3% lactic acid) solutions. However, in ASFL solution, a large number of Ti and Bi ions are released. In addition, Ti-Bi alloys produced no significant deleterious effect to L929 cells and MG63 cells, similar to pure Ti, indicating a good in vitro biocompatibility. Besides, both L929 and MG63 cells perform excellent cell adhesion ability on Ti-Bi alloys. The hemolysis test exhibited that Ti-Bi alloys have an ultra-low hemolysis percentage below 1% and are considered nonhemolytic. To sum up, the Ti-2Bi alloy exhibits the optimal comprehensive performance and has great potential for dental applications.
Collapse
Affiliation(s)
- K J Qiu
- Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001, China
| | - Y Liu
- Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing 100871, China
| | - F Y Zhou
- Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001, China
| | - B L Wang
- Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001, China
| | - L Li
- Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001, China
| | - Y F Zheng
- Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001, China; Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing 100871, China.
| | - Y H Liu
- General Dental Department, School of Stomatology, Peking University, Beijing 100081, China
| |
Collapse
|
49
|
Mohan CC, Prabhath A, Cherian AM, Vadukumpully S, Nair SV, Chennazhi K, Menon D. Nanotextured stainless steel for improved corrosion resistance and biological response in coronary stenting. NANOSCALE 2015; 7:832-841. [PMID: 25436487 DOI: 10.1039/c4nr05015k] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Nanosurface engineering of metallic substrates for improved cellular response is a persistent theme in biomaterials research. The need to improve the long term prognosis of commercially available stents has led us to adopt a 'polymer-free' approach which is cost effective and industrially scalable. In this study, 316L stainless steel substrates were surface modified by hydrothermal treatment in alkaline pH, with and without the addition of a chromium precursor, to generate a well adherent uniform nanotopography. The modified surfaces showed improved hemocompatibility and augmented endothelialization, while hindering the proliferation of smooth muscle cells. Moreover, they also exhibited superior material properties like corrosion resistance, surface integrity and reduced metal ion leaching. The combination of improved corrosion resistance and selective vascular cell viability provided by nanomodification can be successfully utilized to offer a cell-friendly solution to the inherent limitations pertinent to bare metallic stents.
Collapse
Affiliation(s)
- Chandini C Mohan
- Amrita Centre for Nanosciences, Amrita Institute of Medical Science and Research Centre, Amrita Vishwa Vidyapeetham, Cochin 682 041, Kerala, India.
| | | | | | | | | | | | | |
Collapse
|
50
|
Ren X, Feng Y, Guo J, Wang H, Li Q, Yang J, Hao X, Lv J, Ma N, Li W. Surface modification and endothelialization of biomaterials as potential scaffolds for vascular tissue engineering applications. Chem Soc Rev 2015; 44:5680-742. [DOI: 10.1039/c4cs00483c] [Citation(s) in RCA: 359] [Impact Index Per Article: 39.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
This review highlights the recent developments of surface modification and endothelialization of biomaterials in vascular tissue engineering applications.
Collapse
Affiliation(s)
- Xiangkui Ren
- School of Chemical Engineering and Technology
- Tianjin University
- Tianjin 300072
- China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin)
| | - Yakai Feng
- School of Chemical Engineering and Technology
- Tianjin University
- Tianjin 300072
- China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin)
| | - Jintang Guo
- School of Chemical Engineering and Technology
- Tianjin University
- Tianjin 300072
- China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin)
| | - Haixia Wang
- School of Chemical Engineering and Technology
- Tianjin University
- Tianjin 300072
- China
| | - Qian Li
- School of Chemical Engineering and Technology
- Tianjin University
- Tianjin 300072
- China
| | - Jing Yang
- School of Chemical Engineering and Technology
- Tianjin University
- Tianjin 300072
- China
| | - Xuefang Hao
- School of Chemical Engineering and Technology
- Tianjin University
- Tianjin 300072
- China
| | - Juan Lv
- School of Chemical Engineering and Technology
- Tianjin University
- Tianjin 300072
- China
| | - Nan Ma
- Institute of Chemistry and Biochemistry
- Free University of Berlin
- D-14195 Berlin
- Germany
| | - Wenzhong Li
- Department of Cardiac Surgery
- University of Rostock
- D-18057 Rostock
- Germany
| |
Collapse
|