1
|
Kurtz MA, Alaniz K, Kurtz PW, Wessinger AC, Moreno-Reyes A, Gilbert JL. Oxide degradation precedes additively manufactured Ti-6Al-4V selective dissolution: An unsupervised machine learning correlation of impedance and dissolution compared to Ti-29Nb-21Zr. J Biomed Mater Res A 2024; 112:1250-1264. [PMID: 37877770 DOI: 10.1002/jbm.a.37632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 10/09/2023] [Accepted: 10/11/2023] [Indexed: 10/26/2023]
Abstract
Additively manufactured (AM) Ti-6Al-4V devices are implanted with increasing frequency. While registry data report short-term success, a gap persists in our understanding of long-term AM Ti-6Al-4V corrosion behavior. Retrieval studies document β phase selective dissolution on conventionally manufactured Ti-6Al-4V devices. Researchers reproduce this damage in vitro by combining negative potentials (cathodic activation) and inflammatory simulating solutions (H2O2-phosphate buffered saline). In this study, we investigate the effects of these adverse electrochemical conditions on AM Ti-6Al-4V impedance and selective dissolution. We hypothesize that cathodic activation and H2O2 solution will degrade the oxide, promoting corrosion. First, we characterized AM Ti-6Al-4V samples before and after a 48 h -0.4 V hold in 0.1 M H2O2/phosphate buffered saline. Next, we acquired nearfield electrochemical impedance spectroscopy (EIS) data. Finally, we captured micrographs and EIS during dissolution. Throughout, we used AM Ti-29Nb-21Zr as a comparison. After 48 h, AM Ti-6Al-4V selectively dissolved. Ti-29Nb-21Zr visually corroded less. Structural changes at the AM Ti-6Al-4V oxide interface manifested as property changes to the impedance. After dissolution, the log-adjusted constant phase element (CPE) parameter, Q, significantly increased from -4.75 to -3.84 (Scm-2(s)α) (p = .000). The CPE exponent, α, significantly decreased from .90 to .84 (p = .000). Next, we documented a systematic decrease in oxide polarization resistance before pit nucleation and growth. Last, using k-means clustering, we established a structure-property relationship between impedance and the surface's dissolution state. These results suggest that AM Ti-6Al-4V may be susceptible to in vivo crevice corrosion within modular taper junctions.
Collapse
Affiliation(s)
- Michael A Kurtz
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Kazzandra Alaniz
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Peter W Kurtz
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Audrey C Wessinger
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Aldo Moreno-Reyes
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Jeremy L Gilbert
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| |
Collapse
|
2
|
Atapour M, Standish TE, Henderson JD, Wei Z, Dehnavi V, Hedberg YS. Influence of Proteins and Building Direction on the Corrosion and Tribocorrosion of CoCrMo Fabricated by Laser Powder Bed Fusion. ACS Biomater Sci Eng 2024; 10:2880-2893. [PMID: 38630940 DOI: 10.1021/acsbiomaterials.3c01165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
Cobalt-chromium-molybdenum (CoCrMo) alloys are common wear-exposed biomedical alloys and are manufactured in multiple ways, increasingly using additive manufacturing processes such as laser powder bed fusion (LPBF). Here, we investigate the effect of proteins and the manufacturing process (wrought vs LPBF) and building orientation (LPBF-XY and XZ) on the corrosion, metal release, tribocorrosion, and surface oxide composition by means of electrochemical, mechanical, microscopic, diffractive, and spectroscopic methods. The study was conducted at pH 7.3 in 5 g/L NaCl and 5 mM 2-(N-morpholino) ethanesulfonic acid (MES) buffer, which was found to be necessary to avoid metal phosphate and metal-protein aggregate precipitation. The effect of 10 g/L bovine serum albumin (BSA) and 2.5 g/L fibrinogen (Fbn) was studied. BSA and Fbn strongly enhanced the release of Co, Cr, and Mo and slightly enhanced the corrosion (still in the passive domain) for all CoCrMo alloys and most for LPBF-XZ, followed by LPBF-XY and the wrought CoCrMo. BSA and Fbn, most pronounced when combined, significantly decreased the coefficient of friction due to lubrication, the wear track width and severity of the wear mechanism, and the tribocorrosion for all alloys, with no clear effect of the manufacturing type. The wear track area was significantly more oxidized than the area outside of the wear track. In the reference solution without proteins, a strong Mo oxidation in the wear track surface oxide was indicative of a pH decrease and cell separation of the anodic and cathodic areas. This effect was absent in the presence of the proteins.
Collapse
Affiliation(s)
- Masoud Atapour
- Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran
- Department of Chemistry, The University of Western Ontario, London, Ontario, Canada N6A 5B7, Canada
| | - Thalia E Standish
- Surface Science Western, The University of Western Ontario, London, Ontario N6G 0J3, Canada
| | - Jeffrey D Henderson
- Surface Science Western, The University of Western Ontario, London, Ontario N6G 0J3, Canada
| | - Zheng Wei
- Department of Chemistry, The University of Western Ontario, London, Ontario, Canada N6A 5B7, Canada
| | - Vahid Dehnavi
- Surface Science Western, The University of Western Ontario, London, Ontario N6G 0J3, Canada
- Department of Chemical & Biochemical Engineering, The University of Western Ontario, London, Ontario N6A 5B9, Canada
| | - Yolanda S Hedberg
- Department of Chemistry, The University of Western Ontario, London, Ontario, Canada N6A 5B7, Canada
- Surface Science Western, The University of Western Ontario, London, Ontario N6G 0J3, Canada
| |
Collapse
|
3
|
Mann AS, Smith AM, Saltzherr JO, Gopinath A, Andresen Eguiluz RC. Glycosaminoglycans and glycoproteins influence the elastic response of synovial fluid nanofilms on model oxide surfaces. Colloids Surf B Biointerfaces 2022; 213:112407. [PMID: 35180655 DOI: 10.1016/j.colsurfb.2022.112407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 01/27/2022] [Accepted: 02/07/2022] [Indexed: 10/19/2022]
Abstract
Synovial fluid (SF) is the natural lubricant found in articulated joints, providing unique cartilage surface protecting films under confinement and relative motion. While it is known that the synergistic interactions of the macromolecular constituents provide its unique load-bearing and tribological performance, it is not fully understood how two of the main constituents, glycosaminoglycans (GAGs) and glycoproteins, regulate the formation and mechanics of robust load-bearing films. Here, we present evidence that the load-bearing capabilities, rather than the tribological performance, of the formed SF films depend strongly on its components' integrity. For this purpose, we used a combination of enzymatic treatments, quartz crystal microbalance with dissipation (QCM-D), and the surface forces apparatus (SFA) to characterize the formation and load-bearing capabilities of SF films on model oxide (i.e., silicates) surfaces. We find that, upon cleavage of proteins, the elasticity of the films is reduced and that cleaving GAGs results in irreversible (plastic) molecular re-arrangements of the film constituents when subjected to confinement. Understanding thin film mechanics of SF can provide insight into the progression of diseases, such as arthritis, but may also be applicable to the development of new implant surface treatments or new biomimetic lubricants.
Collapse
Affiliation(s)
- Amar S Mann
- Department of Materials Science and Engineering, University of California, Merced, CA 95344, USA
| | - Ariell M Smith
- Department of Materials Science and Engineering, University of California, Merced, CA 95344, USA
| | - Joyce O Saltzherr
- Department of Materials Science and Engineering, University of California, Merced, CA 95344, USA
| | - Arvind Gopinath
- Department of Bioengineering, University of California, Merced, CA 95344, USA; Health Sciences Research Institute, University of California, Merced, CA 95344, USA
| | - Roberto C Andresen Eguiluz
- Department of Materials Science and Engineering, University of California, Merced, CA 95344, USA; Health Sciences Research Institute, University of California, Merced, CA 95344, USA.
| |
Collapse
|
4
|
The Electrochemical Behavior of Ti in Human Synovial Fluids. MATERIALS 2022; 15:ma15051726. [PMID: 35268957 PMCID: PMC8910938 DOI: 10.3390/ma15051726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 02/21/2022] [Accepted: 02/23/2022] [Indexed: 11/18/2022]
Abstract
In this study, we report results of the interaction of titanium (Ti) with human synovial fluids. A wide palette of electrochemical techniques was used, including open circuit potential, potentiodynamic methods, and electrochemical impedance. After the electrochemical testing, selected surfaces were analyzed using Auger Electron Spectroscopy to provide laterally resolved information on surface chemistry. For comparison purposes, similar tests were conducted in a series of simulated body fluids. This study shows that compared to the tested simulated body fluids, synovial liquids show a large patient variability up to one order of magnitude for some crucial electrochemical parameters such as corrosion current density. The electrochemical behavior of Ti exposed to human synovial fluids seems to be controlled by the interaction with organic molecules rather than with reactive oxygen species.
Collapse
|
5
|
Gómez Taborda Y, Gómez Botero M, Castaño-González JG, Bermúdez-Castañeda A. Assessment of physical, chemical, and tribochemical properties of biomedical alloys used in explanted modular hip prostheses. Proc Inst Mech Eng H 2021; 236:9544119211061928. [PMID: 34931555 DOI: 10.1177/09544119211061928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
During their service life, modular interfaces experience tribological, and corrosion phenomena that lead to deterioration, which in turn can cause a revision procedure to remove the failed prosthesis. To achieve a clearer understanding of the surface performance of those biomedical alloys and the role of the surface properties in the mechanical and chemical performance, samples were taken from retrieval implants made of Ti6Al4V and Co28Cr6Mo alloys. Polarization resistance and pin-on-disk tests were performed on these samples. Physical properties such as contact angle, roughness, microhardness, and Young's modulus were determined. A correlation between surface energy and evolution of the tribological contact was observed for both biomedical alloys. In tribocorrosion tests, titanium particles seem to remain in the surface, unlike what is observed in CoCr alloys. These metallic or oxidized particles could cause necrosis or adverse tissue reactions.
Collapse
Affiliation(s)
- Yesenia Gómez Taborda
- Centro de Investigación, Innovación y Desarrollo de Materiales - CIDEMAT, Universidad de Antioquia, Medellín, Colombia
| | - Maryory Gómez Botero
- Centro de Investigación, Innovación y Desarrollo de Materiales - CIDEMAT, Universidad de Antioquia, Medellín, Colombia
| | | | - Angela Bermúdez-Castañeda
- Diseño Sostenible en Ingeniería Mecánica - DSIM, Escuela Colombiana de Ingeniería Julio Garavito, Bogotá, Colombia
| |
Collapse
|
6
|
Neto MQ, Radice S, Hall DJ, Mathew MT, Mercuri LG, Pourzal R. Alloys used in different Temporomandibular joint reconstruction replacement prostheses exhibit variable microstructures and electrochemical properties. J Oral Maxillofac Surg 2021; 80:798-813. [DOI: 10.1016/j.joms.2021.12.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 12/17/2021] [Accepted: 12/24/2021] [Indexed: 01/30/2023]
|
7
|
Gilbert JL. CORR Insights®: Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res 2021; 479:2097-2099. [PMID: 34283814 PMCID: PMC8373574 DOI: 10.1097/corr.0000000000001904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 06/28/2021] [Indexed: 01/31/2023]
Affiliation(s)
- Jeremy L Gilbert
- Hansjörg Wyss SmartState Endowed Chair for Regenerative Medicine, Professor of Bioengineering, Clemson University, Clemson, SC, USA
| |
Collapse
|
8
|
McCarthy SM, Hall DJ, Mathew MT, Jacobs JJ, Lundberg HJ, Pourzal R. Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res 2021; 479:2083-2096. [PMID: 34019490 PMCID: PMC8373544 DOI: 10.1097/corr.0000000000001819] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 04/19/2021] [Indexed: 01/31/2023]
Abstract
BACKGROUND Fretting and corrosion in metal-on-polyethylene total hip arthoplasty (THA) modular junctions can cause adverse tissue reactions that are responsible for 2% to 5% of revision surgeries. Damage within cobalt-chromium-molybdenum (CoCrMo) alloy femoral heads can progress chemically and mechanically, leading to damage modes such as column damage, imprinting, and uniform fretting damage. At present, it is unclear which of these damage modes are most detrimental and how they may be linked to implant alloy metallurgy. The alloy microstructure exhibits microstructural features such as grain boundaries, hard phases, and segregation bands, which may enable different damage modes, higher material loss, and the potential risk of adverse local tissue reactions. QUESTIONS/PURPOSES In this study, we asked: (1) How prevalent is chemically dominated column damage compared with mechanically dominated damage modes in severely damaged metal-on-polyethylene THA femoral heads made from wrought CoCrMo alloy? (2) Is material loss greater in femoral heads that underwent column damage? (3) Do material loss and the presence of column damage depend on alloy microstructure as characterized by grain size, hard phase content, and/or banding? METHODS Surgically retrieved wrought CoCrMo modular femoral heads removed between June 2004 and June 2019 were scored using a modified version of the Goldberg visually based scoring system. Of the total 1002 heads retrieved over this period, 19% (190 of 1002) were identified as severely damaged, exhibiting large areas of fretting scars, black debris, pits, and/or etch marks. Of these, 43% (81 of 190) were excluded for metal-on-metal articulations, alternate designs (such as bipolar, dual-mobility, hemiarthroplasty, metal adaptor sleeves), or previous sectioning of the implant for past studies. One sample was excluded retroactively as metallurgical analysis revealed that it was made of cast alloy, yielding a total of 108 for further analysis. Information on patient age (57 ± 11 years) and sex (56% [61 of 108] were males), reason for removal, implant time in situ (99 ± 78 months), implant manufacturer, head size, and the CoCrMo or titanium-based stem alloy pairing were collected. Damage modes and volumetric material loss within the head tapers were identified using an optical coordinate measuring machine. Samples were categorized by damage mode groups by column damage, imprinting, a combination of column damage and imprinting, or uniform fretting. Metallurgical samples were processed to identify microstructural characteristics of grain size, hard phase content, and banding. Nonparametric Mann-Whitney U and Kruskal-Wallis statistical tests were used to examine volumetric material loss compared with damage mode and microstructural features, and linear regression was performed to correlate patient- and manufacturer-specific factors with volumetric material loss. RESULTS Chemically driven column damage was seen in 48% (52 of 108) of femoral heads, with 34% (37 of 108) exhibiting a combination of column damage and imprinting, 12% (13 of 108) of heads displaying column damage and uniform fretting, and 2% (2 of 108) exhibiting such widespread column damage that potentially underlying mechanical damage modes could not be verified. Implants with column damage showed greater material loss than those with mechanically driven damage alone, with median (range) values of 1.2 mm3 (0.2 to 11.7) versus 0.6 mm3 (0 to 20.7; p = 0.03). Median (range) volume loss across all femoral heads was 0.9 mm3 (0 to 20.7). Time in situ, contact area, patient age, sex, head size, manufacturer, and stem alloy type were not associated with volumetric material loss. Banding of the alloy microstructure, with a median (range) material loss of 1.1 mm3 (0 to 20.7), was associated with five times higher material loss compared with those with a homogeneous microstructure, which had a volume loss of 0.2 mm3 (0 to 4.1; p = 0.02). Hard phase content and grain size showed no correlation with material loss. CONCLUSION Chemically dominated column damage was a clear indicator of greater volume loss in this study sample of 108 severely damaged heads. Volumetric material loss strongly depended on banding (microstructural segregations) within the alloy. Banding of the wrought CoCrMo microstructure should be avoided during the manufacturing process to reduce volumetric material loss and the release of corrosion products to the periprosthetic tissue. CLINICAL RELEVANCE Approximately 30% of THAs rely on wrought CoCrMo femoral heads. Most femoral heads in this study exhibited a banded microstructure that was associated with larger material loss and the occurrence of chemically dominated column damage. This study suggests that elimination of banding from the alloy could substantially reduce the release of implant debris in vivo, which could potentially also reduce the risk of adverse local tissue reactions to implant debris.
Collapse
Affiliation(s)
| | - Deborah J. Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | | | - Joshua J. Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Hannah J. Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
9
|
Wimmer M, Radice S, Janssen D, Fischer A. Fretting-corrosion of CoCr-alloys against TiAl6V4: The importance of molybdenum in oxidative biological environments. WEAR : AN INTERNATIONAL JOURNAL ON THE SCIENCE AND TECHNOLOGY OF FRICTION LUBRICATION AND WEAR 2021; 477:203813. [PMID: 34690379 PMCID: PMC8528050 DOI: 10.1016/j.wear.2021.203813] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Periprosthetic fluids often contain reactive oxygen species, including H2O2, that are generated during inflammatory processes. Here, we investigated the fretting-corrosion behavior of CoCrX-alloys (X = Mo, Fe) in a complex protein-containing lubricant, with and without the addition of H2O2. Given the known protective role of molybdenum as an alloying element in metal degradation, we considered its effects by designing a two-way factorial experiment. The aim of the study was to investigate tribocorrosive mechanisms in modular joints of knee and hip prostheses. A previously described test-rig was used to run fretting corrosion tests of CoCrX-alloys with (X=Mo) and without (X=Fe) molybdenum against TiAl6V4 in bovine calf serum (BCS) with and without a physiological relevant H2O2 level (3 mM) in gross slip mode (4 Hz, ±50 μm, pmax=0.18 GPa, 37 °C, 50,000 cycles). Two CoCr-pins were pressed against a cylindrical TiAl6V4-rod, forming a line contact. Normal and frictional forces, the displacement, and the open circuit potential (OCP) were measured and recorded continuously. The dissipated frictional work was independent of alloy composition. The addition of H2O2 lowered the dissipated frictional work and increased wear, and this was significant in the absence of Mo. The mean OCP value was lower with Mo-containing than with Mo-free alloy in both pure BCS (p = .042), and BCS ± H2O2 (p < .0005). The wear scar was deeper for the Mo-free alloy, and this was significant (p = .013) in the presence of H2O2. These findings suggest a marked weakening of the passive film in the presence of H2O2, which is mitigated by the availability of Mo.
Collapse
Affiliation(s)
- M.A. Wimmer
- Rush University Medical Center, Chicago, IL, USA
| | - S. Radice
- Rush University Medical Center, Chicago, IL, USA
| | - D. Janssen
- University of Duisburg-Essen, Materials Science and Engineering, Duisburg, Germany
| | - A. Fischer
- Rush University Medical Center, Chicago, IL, USA
- University of Duisburg-Essen, Materials Science and Engineering, Duisburg, Germany
| |
Collapse
|
10
|
Wu H, Wang Z, Liu S, Meng H, Liu S, Fu S. Sub-toxic levels of cobalt ions impair chondrocyte mechanostranduction via HDAC6-dependent primary cilia shortening. Biochem Biophys Res Commun 2021; 544:38-43. [PMID: 33516880 DOI: 10.1016/j.bbrc.2021.01.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 01/15/2021] [Indexed: 10/22/2022]
Abstract
Cobalt ions are the main wear particles associated with orthopaedic implants, causing adverse complications due to cytotoxicity and inflammatory mediators. Recent studies have shown that sub-toxic levels of cobalt ions regulate matrix synthesis and inflammation, but the influence of cobalt ions on mechanotransduction remains unclear. Previously, we reported that sub-toxic levels of cobalt ions modulated primary cilia, which are crucial for mechanotransduction. This study therefore aimed to investigate the effect of cobalt ions on chondrocyte mechanosensation in response to cyclic tensile strain and the association with primary cilia. Sub-toxic levels of cobalt ions impaired chondrocyte mechanosensation and affected the gene expression of aggrecan, collagen II and MMP-13. Moreover, cobalt ions induced HDAC6-dependent primary cilia disassembly, which was associated with either cytoplasmic or ciliary α-tubulin deacetylation. Pharmaceutical HDAC6 inhibition with tubacin restored primary cilia length and mechanotransduction, whereas chemical depletion of primary cilia by chloral hydrate prevented mechanosignalling. Thus, sub-toxic levels of cobalt ions impaired chondrocyte mechanotransduction via HDAC6 activation, which was associated with tubulin deacetylation and primary cilia shortening.
Collapse
Affiliation(s)
- Han Wu
- Department of Orthopedics, The First Affiliated Hospital of Zhengzhou University, China.
| | - Zhao Wang
- Department of Orthopedics, The Third Affiliated Hospital of Guangzhou University, China.
| | - Song Liu
- Department of Orthopedics, The Third Affiliated Hospital of Guangzhou University, China.
| | - Huan Meng
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, UK.
| | - Shengyuan Liu
- College of Life Science, Northeast Agricultural University, China.
| | - Su Fu
- Department of Orthopedics, The First Affiliated Hospital of Zhengzhou University, China.
| |
Collapse
|
11
|
Erfanian-Nazif-Toosi HR, Rodriguez M, López HF. Microstructural evolution and corrosion behavior of a laser surface modified cast Co-Cr-Mo-C alloy. J Biomed Mater Res B Appl Biomater 2020; 108:3190-3199. [PMID: 32619316 DOI: 10.1002/jbm.b.34644] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 05/01/2020] [Accepted: 05/09/2020] [Indexed: 11/10/2022]
Abstract
A Co-Cr-Mo-C biomedical alloy was processed by investment casting, and its surface was modified using pulsed laser melting. The modified surface underwent rapid solidification, and the exhibited microstructure as well as its corrosion properties were investigated. It was found that the laser surface modified (LSM) Co-Cr-Mo-C alloy possesses enhanced corrosion resistance when compared with the same alloy in the as-cast condition. Microstructural determinations indicated that the LSM Co-Cr-Mo-C alloy exhibited a lack significant solute segregation and a predominantly cellular morphology as a result of the development of a cellular solid-liquid front. The cellular morphology was characterized by a fine distribution of nano-scale M23 C6 carbides at the intercellular regions. Moreover, the austenite (γ) to athermal ε-martensite transformation was totally suppressed in the cellular solidified regions. In contrast, the as-cast alloy develops a coarse dendritic microstructure with coarse carbides in the interdendritic regions. Solute segregation is also present, as well as athermal ε-martensite (13 pct). It was found that the corrosion resistance of the LSM alloy in the Ringer solution exhibits improved corrosion potential and a reduced corrosion current density (-281 mV and 0.032 μA/cm2 , respectively),when compared with the same alloy in the investment as-cast condition (-356 mV and 0.150 μA/cm2 ).
Collapse
Affiliation(s)
| | - Mario Rodriguez
- Center for Advancced Materials, Technological Institute of Saltilo, Saltillo, Coahuila, Mexico
| | - Hugo F López
- Department of Materials Science and Engineering, University of Wisconsin-Miilwaukee, Milwaukee, Wisconsin, USA
| |
Collapse
|
12
|
Wiegand MJ, Khullar P, Mercuri JJ, Gilbert JL. Synthetic periprosthetic synovial fluid development for in vitro cell-tribocorrosion testing using the Taguchi array approach. J Biomed Mater Res A 2020; 109:551-561. [PMID: 32946189 DOI: 10.1002/jbm.a.37039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 06/04/2020] [Accepted: 06/09/2020] [Indexed: 12/26/2022]
Abstract
Synovial fluid is dynamic in vivo with biological components changing in ratio and size depending on the health of the joint space, making it difficult to model in vitro. Previous efforts to develop synthetic synovial fluid have typically focused on single organic-tribological interactions with implant surfaces, thus ignoring interplay between multiple solution components. Using a Taguchi orthogonal array, we were able to isolate the individual effects of five independent synovial fluid composition variables: ratios of (1) hyaluronic acid to phospholipids (HA:PL) and (2) albumin to globulin (A:G), and concentrations of (3) hydrogen peroxide (H2 O2 ), (4) cobalt (Co2+ ) and (5) chromium (Cr3+ ) ions on macrophage viability and reduced glutathione production, local solution pH and the comprehensive CoCrMo alloy electrochemical response. While no single synovial fluid variable significantly affected the collective response, HA:PL ratio resulted in the largest impact factor (Δ) on 12 of the 13 measured responses with significant effects (p < .05) on the average macrophage survival rate and electrochemical capacitive state of the CoCrMo surface. Cluster analysis separated significant responses from all trials into three groups, corresponding to healthy, mild, or severely inflamed fluids, respectively; with the healthy synovial fluid composition having mid-range HA:PL ratios with no Co2+ ions, and the severely inflamed fluids consisting of low and high HA:PL ratios with H2 O2 and Co2+ ions. By utilizing the Taguchi approach in combination with cluster analysis, we were able to advance our knowledge of complex multivariate synthetic synovial fluids influence on macrophage and electrochemical behavior at the cell-solution-metal interface.
Collapse
Affiliation(s)
- Michael J Wiegand
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.,The Clemson University-Medical University of South Carolina Program in Bioengineering, Clemson University, Charleston, South Carolina, USA
| | - Piyush Khullar
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.,The Clemson University-Medical University of South Carolina Program in Bioengineering, Clemson University, Charleston, South Carolina, USA
| | - Jeremy J Mercuri
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
| | - Jeremy L Gilbert
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.,The Clemson University-Medical University of South Carolina Program in Bioengineering, Clemson University, Charleston, South Carolina, USA
| |
Collapse
|
13
|
Heise G, Black CM, Smith R, Morrow BR, Mihalko WM. In vitro effects of macrophages on orthopaedic implant alloys and local release of metallic alloy components. Bone Joint J 2020; 102-B:116-121. [PMID: 32600200 DOI: 10.1302/0301-620x.102b7.bjj-2019-1556.r1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
AIMS This study aimed to determine if macrophages can attach and directly affect the oxide layers of 316L stainless steel, titanium alloy (Ti6Al4V), and cobalt-chromium-molybdenum alloy (CoCrMo) by releasing components of these alloys. METHODS Murine peritoneal macrophages were cultured and placed on stainless steel, CoCrMo, and Ti6Al4V discs into a 96-well plate. Cells were activated with interferon gamma and lipopolysaccharide. Macrophages on stainless steel discs produced significantly more nitric oxide (NO) compared to their control counterparts after eight to ten days and remained elevated for the duration of the experiment. RESULTS On stainless steel, both nonactivated and activated cell groups were shown to have a significant increase in metal ion release for Cr, Fe, and Ni (p < 0.001, p = 0.002, and p = 0.020 respectively) compared with medium only and showed macrophage-sized corrosive pits on the stainless steel surface. On titanium alloy discs there was a significant increase in aluminum (p < 0.001) among all groups compared with medium only. CONCLUSION These results indicated that macrophages were able to attach to and affect the oxide surface of stainless steel and titanium alloy discs. Cite this article: Bone Joint J 2020;102-B(7 Supple B):116-121.
Collapse
Affiliation(s)
- G Heise
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| | - C M Black
- College of Medicine, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| | - R Smith
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| | - B R Morrow
- College of Dentistry, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| | - W M Mihalko
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| |
Collapse
|
14
|
de Castro Girão D, Béreš M, Jardini AL, Filho RM, Silva CC, de Siervo A, Gomes de Abreu HF, Araújo WS. An assessment of biomedical CoCrMo alloy fabricated by direct metal laser sintering technique for implant applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 107:110305. [DOI: 10.1016/j.msec.2019.110305] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 06/22/2018] [Accepted: 10/11/2019] [Indexed: 10/25/2022]
|
15
|
Effects of bovine serum albumin and hyaluronic acid on the electrochemical response of a CoCrMo alloy to cathodic and anodic excursions. ACTA ACUST UNITED AC 2019; 5. [PMID: 31828005 DOI: 10.1007/s40735-019-0299-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The problem of wear and corrosion of CoCrMo-implant surfaces in the human body following total joint replacement has been commonly investigated with tribocorrosion tests, using different lubricants meant to simulate the pseudo-synovial fluid. While results considering the synovial fluid components separately have highlighted their individual influence on the tribological performance of CoCrMo-alloy, an understanding about the influence of the synovial fluid components under the electrochemical point of view is missing. This work aims to investigate the effect of bovine serum albumin (BSA) and hyaluronic acid (HA) on electrochemical potential variations of CoCrMo alloys tested in a model synovial fluid. To simulate the environment inside the synovial capsule, the tests were performed inside a CO2 incubator at 37°C. Open circuit potential, electrochemical impedance spectroscopy, cathodic and anodic potentiodynamic measurements were performed with different electrolytes, prepared with cell culture medium (RMPI-1640), BSA and HA. The final CoCrMo-surface was analyzed by SEM/EDS and infrared spectroscopy. The influence of HA on the corrosion of the CoCrMo-alloy depended on the presence of BSA proteins adsorbed on the CoCrMo-surface: EIS and anodic polarization results showed a corrosive action of HA in the absence of adsorbed proteins. In the presence of both BSA and HA, organometallic precipitates were found on the CoCrMo surface following reverse anodic polarization, which remind of corrosion products found in-vivo. These results indicate that HA affects the interaction of CoCrMo implant alloys with protein-containing model synovial fluids, and suggest that HA needs to be considered in tribocorrosion studies for more clinically relevant outcomes.
Collapse
|
16
|
Stotter C, Stojanović B, Bauer C, Rodríguez Ripoll M, Franek F, Klestil T, Nehrer S. Effects of Loading Conditions on Articular Cartilage in a Metal-on-Cartilage Pairing. J Orthop Res 2019; 37:2531-2539. [PMID: 31334864 PMCID: PMC6899800 DOI: 10.1002/jor.24426] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 07/15/2019] [Indexed: 02/04/2023]
Abstract
The aim of this in vitro study was to investigate the response of articular cartilage to frictional load when sliding against a metal implant, and identify potential mechanisms of damage to articular cartilage in a metal-on-cartilage pairing. Bovine osteochondral cylinders were reciprocally slid against metal cylinders (cobalt-chromium-molybdenum alloy) with several variations of load and sliding velocity using a microtribometer. The effects of different loads and velocities, and the resulting friction coefficients on articular cartilage, were evaluated by measuring histological and metabolic outcomes. Moreover, the biotribocorrosion of the metal was determined. Chondrocytes stimulated with high load and velocity showed increased metabolic activity and cartilage-specific gene expression. In addition, higher load and velocity resulted in biotribocorrosion of the metal implant and damage to the surface of the articular cartilage, whereas low velocity and a high coefficient of friction increased the expression of catabolic genes. Articular cartilage showed particular responses to load and velocity when sliding against a metal implant. Moreover, metal implants showed tribocorrosion. Therefore, corrosion particles may play a role in the mechano-biochemical wear of articular cartilage after implantation of a metal implant. These findings may be useful to surgeons performing resurfacing procedures and total knee arthroplasty. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society J Orthop Res 37:2531-2539, 2019.
Collapse
Affiliation(s)
- Christoph Stotter
- Faculty of Health and Medicine, Department for Health Sciences, Medicine and Research, Center for Regenerative MedicineDanube University KremsDr. Karl‐Dorrek‐Str. 30KremsA‐3500Austria,Department of Orthopedics and TraumatologyLK Baden‐Mödling‐HainburgWaltersdorfer Straße 75A‐2500BadenAustria
| | - Bojana Stojanović
- AC2T Research GmbHViktor Kaplan‐Straße 2A‐2700Wiener NeustadtAustria
| | - Christoph Bauer
- Faculty of Health and Medicine, Department for Health Sciences, Medicine and Research, Center for Regenerative MedicineDanube University KremsDr. Karl‐Dorrek‐Str. 30KremsA‐3500Austria
| | | | - Friedrich Franek
- AC2T Research GmbHViktor Kaplan‐Straße 2A‐2700Wiener NeustadtAustria
| | - Thomas Klestil
- Department of Orthopedics and TraumatologyLK Baden‐Mödling‐HainburgWaltersdorfer Straße 75A‐2500BadenAustria,Faculty of Health and Medicine, Department for Health Sciences, Medicine and ResearchDanube University KremsDr. Karl‐Dorrek‐Str. 30KremsA‐3500Austria
| | - Stefan Nehrer
- Faculty of Health and Medicine, Department for Health Sciences, Medicine and Research, Center for Regenerative MedicineDanube University KremsDr. Karl‐Dorrek‐Str. 30KremsA‐3500Austria
| |
Collapse
|
17
|
Local Biological Reactions and Pseudotumor-Like Tissue Formation in relation to Metal Wear in a Murine In Vivo Model. BIOMED RESEARCH INTERNATIONAL 2019; 2019:3649838. [PMID: 31781613 PMCID: PMC6855077 DOI: 10.1155/2019/3649838] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 05/18/2019] [Accepted: 09/17/2019] [Indexed: 12/12/2022]
Abstract
Metal wear debris and released ions (CoCrMo), which are widely generated in metal-on-metal bearings of hip implants, are also found in patients with metal-on-polyethylene bearings due to the mechanically assisted crevice corrosion of modular taper junctions, including head-neck and neck-stem taper interfaces. The resulting adverse reactions to metal debris and metal ions frequently lead to early arthroplasty revision surgery. National guidelines have since been published where the blood metal ion concentration of patients must consistently be monitored after joint replacement to prevent serious complications from developing after surgery. However, to date, the effect of metal particles and metal ions on local biological reactions is complex and still not understood in detail; the present study sought to elucidate the complex mechanism of metal wear-associated inflammation reactions. The knee joints in 4 groups each consisting of 10 female BALB/c mice received injections with cobalt chrome ions, cobalt chrome particles, and ultra-high-molecular-weight polyethylene (UHMWPE) particles or PBS (control). Seven days after injection, the synovial microcirculation and knee joint diameter were assessed via intravital fluorescence microscopy followed by histological evaluation of the synovial layer. Enlarged knee diameter, enhanced leukocyte to endothelial cell interactions, and an increase in functional capillary density within cobalt chrome particle-treated animals were significantly greater than those in the other treatment groups. Subsequently, pseudotumor-like tissue formations were observed only in the synovial tissue layer of the cobalt chrome particle-treated animals. Therefore, these findings strongly suggest that the cobalt chrome particles and not metal ions are the cause for in vivo postsurgery implantation inflammation.
Collapse
|
18
|
Stojanović B, Bauer C, Stotter C, Klestil T, Nehrer S, Franek F, Rodríguez Ripoll M. Tribocorrosion of a CoCrMo alloy sliding against articular cartilage and the impact of metal ion release on chondrocytes. Acta Biomater 2019; 94:597-609. [PMID: 31226479 DOI: 10.1016/j.actbio.2019.06.015] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 06/11/2019] [Accepted: 06/13/2019] [Indexed: 01/22/2023]
Abstract
Partial knee replacement and hemiarthroplasty are some of the orthopedic procedures resulting in a metal on cartilage interface. As metal implant material, CoCrMo based alloys are commonly used. The aim of the present study is to assess the role of biotribocorrosion on the CoCrMo-cartilage interface with an emphasis on metal release during sliding contact. The biotribocorrosion experiments were performed under controlled electrochemical conditions using a floating cell with a three electrode set up coupled to a microtribometer. Throughout the experiment the coefficient of friction and the open circuit potential were monitored. Analyses of the electrolyte after the experiment show that metal release can occur during sliding contact of CoCrMo alloy against articular cartilage despite the extraordinary low coefficient of friction measured. Metal release is attributed to changes in passive layer caused at the onset of sliding. The released metal was found to be forming compounds with potential cytotoxicity. Since the presence of metal ions in the cartilage matrix can potentially lead to cell apoptosis, the metabolic activity of human osteoarthritic chondrocytes (2D-cultures) was investigated in the presence of phosphate buffered saline containing metal ions using XTT-assay. The experiments indicate that critical concentrations of Co ions lead to a significant decrease in chondrocyte metabolic activity. Therefore, biotribocorrosion is a mechanism that can occur in partial replacements and lead to chondrocyte apoptosis thus playing a role in the observed accelerated degradation of the remaining cartilage tissue after the mentioned orthopedic procedures. STATEMENT OF SIGNIFICANCE: Partial replacements provide an alternative to total joint replacements. This procedure is less invasive, allows a faster rehabilitation and provides a better function of the joint. However, the remaining native cartilage experiences accelerated degradation when in contact with metallic implant components. This work investigates the role of tribocorrosion at the metal-cartilage interface during sliding. Tribocorrosion is a degradation process that can alter significantly the wear rates experienced by metallic implants and lead to the release of metal ions and particles. The released metal can form compounds with potential cytotoxicity on cartilage tissue. The knowledge gained in this work will serve to understand the mechanisms behind the failure of partial replacements and develop future biomaterials with an enhanced lifetime.
Collapse
Affiliation(s)
- B Stojanović
- AC2T research GmbH, Viktor Kaplan-Straße 2/C, A-2700 Wiener Neustadt, Austria
| | - C Bauer
- Danube University Krems, Faculty of Health and Medicine, Department for Health Sciences and Biomedicine, Center for Regenerative Medicine and Orthopedics, Dr. Karl-Dorrek-Str. 30, A-3500 Krems, Austria
| | - C Stotter
- Danube University Krems, Faculty of Health and Medicine, Department for Health Sciences and Biomedicine, Center for Regenerative Medicine and Orthopedics, Dr. Karl-Dorrek-Str. 30, A-3500 Krems, Austria; LK Baden-Mödling-Hainburg, Department of Orthopedics and Traumatology, Waltersdorferstraße 75, A-2500 Baden, Austria
| | - T Klestil
- LK Baden-Mödling-Hainburg, Department of Orthopedics and Traumatology, Waltersdorferstraße 75, A-2500 Baden, Austria; Danube University Krems, Faculty of Health and Medicine, Department for Health Sciences and Biomedicine, Center for Medical Specializations, Dr. Karl-Dorrek-Str. 30, A-3500 Krems, Austria
| | - S Nehrer
- Danube University Krems, Faculty of Health and Medicine, Department for Health Sciences and Biomedicine, Center for Regenerative Medicine and Orthopedics, Dr. Karl-Dorrek-Str. 30, A-3500 Krems, Austria
| | - F Franek
- AC2T research GmbH, Viktor Kaplan-Straße 2/C, A-2700 Wiener Neustadt, Austria
| | - M Rodríguez Ripoll
- AC2T research GmbH, Viktor Kaplan-Straße 2/C, A-2700 Wiener Neustadt, Austria.
| |
Collapse
|
19
|
Eltit F, Wang Q, Wang R. Mechanisms of Adverse Local Tissue Reactions to Hip Implants. Front Bioeng Biotechnol 2019; 7:176. [PMID: 31417898 PMCID: PMC6683860 DOI: 10.3389/fbioe.2019.00176] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 07/08/2019] [Indexed: 12/11/2022] Open
Abstract
Adverse Local Tissue Reactions (ALTRs) are one of the main causes of hip implant failures. Although the metal release from the implants is considered as a main etiology, the mechanisms, and the roles of the released products are topics of ongoing research. The alloys used in the hip implants are considered biocompatible and show negligible corrosion in the body environment under static conditions. However, modularity and its associated mechanically assisted corrosion have been shown to release metal species into the body fluids. ALTRs associated with metal release have been observed in hip implants with metal-on-metal articulation initially, and later with metal-on-polyethylene articulation, the most commonly used design in current hip replacement. The etiological factors in ALTRs have been the topics of many studies. One commonly accepted theory is that the interactions between the metal species and body proteins and cells generate a delayed type IV hypersensitivity reaction leading to ALTRs. However, lymphocyte reactions are not always observed in ALTRS, and the molecular mechanisms have not been clearly demonstrated. A more accepted mechanism is that cell damage generated by metal ions may trigger the secretion of cytokines leading to the inflammatory reactions observed in ALTRs. In this inflammatory environment, some patients would develop hypersensitivity that is associated with poor outcomes. Concerns over ALTRS have brought significant impact to both the clinical selection and development of hip implants. This review is focused on the mechanisms of ALTRs, specifically, the metal release process and the roles of the metal species released in the etiology and pathogenesis of the disease. Hopefully, our presentation and discussion of this biological process from a material perspective could improve our current understanding on the ALTRs and provide useful guidance in developing preventive solutions.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Qiong Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| |
Collapse
|
20
|
Impergre A, Trunfio-Sfarghiu A, Der-Loughian C, Brizuela L, Mebarek S, Ter-Ovanessian B, Bel-Brunon A, Berthier Y, Normand B. Tribocorrosion of Polyethylene/Cobalt Contact Combined with Real-Time Fluorescence Assays on Living Macrophages: Development of A Multidisciplinary Biotribocorrosion Device. ACTA ACUST UNITED AC 2019. [DOI: 10.1016/j.biotri.2019.100091] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
21
|
Pardo A, Ilic E, Thorwarth K, Stiefel M, Hauert R. Corrosion fatigue in DLC-coated articulating implants: an accelerated methodology to predict realistic interface lifetime. SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS 2019; 20:173-186. [PMID: 30891104 PMCID: PMC6419647 DOI: 10.1080/14686996.2019.1580483] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 01/25/2019] [Accepted: 01/25/2019] [Indexed: 06/09/2023]
Abstract
We present a methodology to accelerate and estimate the lifetime of an interlayer under dynamic loading in body-like media. It is based on accelerating corrosion fatigue processes taking place at the buried interface of a Si-based adhesion-promoting interlayer in articulating implants on a CoCrMo biomedical alloy; the implants are coated with diamond-like carbon (DLC). The number of interface loading cycles to delamination is determined by reciprocal loading in corrosive fluid. Its dependence on the load is summarized in a Wöhler-like curve of a DLC/DLC-Si/CoCrMo system in body working conditions: cyclic stresses at 37 °C in phosphate buffered saline (PBS). The presence of oxygen as a contaminant strongly affects the lifetime of the interface under corrosion fatigue. The main parameters acting on the prediction, with a special emphasis on simulated in vivo conditions, are analyzed and discussed: the media (PBS, Milli-Q water, NaCl, Ringers' solution and bovine calf serum), the load, the frequency and the composition of the interface determined by X-ray photoelectron spectroscopy.
Collapse
Affiliation(s)
- Ainhoa Pardo
- Laboratory for Joining Technologies and Corrosion, Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-Dübendorf, Switzerland
| | - Emilija Ilic
- Laboratory for Joining Technologies and Corrosion, Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-Dübendorf, Switzerland
| | - Kerstin Thorwarth
- Laboratory for Nanoscaled Materials Science, Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-Dübendorf, Switzerland
| | - Michael Stiefel
- Laboratory for Transport at Nanoscale Interfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-Dübendorf, Switzerland
| | - Roland Hauert
- Laboratory for Joining Technologies and Corrosion, Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-Dübendorf, Switzerland
| |
Collapse
|
22
|
Xu W, Zhang B, Yang L, Ni Q, Li Y, Yu F. Effect of the coexistence of albumin and H2O2on the corrosion of biomedical cobalt alloys in physiological saline. RSC Adv 2019; 9:32954-32965. [PMID: 35529113 PMCID: PMC9073266 DOI: 10.1039/c9ra05699h] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Accepted: 09/24/2019] [Indexed: 11/25/2022] Open
Abstract
The corrosion of Co–28Cr–6Mo and Co–35Ni–20Cr–10Mo, as biomedical alloys, has been investigated for effects of typical species (albumin and H2O2) in physiological saline, with their coexistence explored for the first time. Electrochemical and long term immersion tests were carried out. It was found that Co alloys were not sensitive to the presence of albumin alone, which slightly promoted anodic dissolution of Co–35Ni–20Cr–10Mo without noticeably affecting Co–28Cr–6Mo and facilitated oxide film dissolution on both alloys. H2O2 led to a clear drop in corrosion resistance, favouring metal release and surface oxide formation and inducing much thicker but less compact oxide films for both alloys. The coexistence of both species resulted in the worst corrosion resistance and most metal release, while the amount and composition of surface oxide remained at a similar level as in the absence of both. The effect of H2O2 inducing low compactness of surface oxides should prevail on deciding the poor corrosion protection ability of passive film, while albumin simultaneously promoted dissolution or inhibited formation of oxides due to H2O2. Corrosion resistance was consistently lower for Co–35Ni–20Cr–10Mo under each condition, the only alloy where the synergistic effect of both species was clearly demonstrated. This work suggests that the complexity of the environment must be considered for corrosion resistance evaluation of biomedical alloys. Corrosion of biomedical Co alloys were firstly studied in the presence of both albumin and H2O2.![]()
Collapse
Affiliation(s)
- Weichen Xu
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling
- Institute of Oceanology
- Chinese Academy of Sciences
- Qingdao 266071
- People's Republic of China
| | - Binbin Zhang
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling
- Institute of Oceanology
- Chinese Academy of Sciences
- Qingdao 266071
- People's Republic of China
| | - Lihui Yang
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling
- Institute of Oceanology
- Chinese Academy of Sciences
- Qingdao 266071
- People's Republic of China
| | - Qiancheng Ni
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling
- Institute of Oceanology
- Chinese Academy of Sciences
- Qingdao 266071
- People's Republic of China
| | - Yantao Li
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling
- Institute of Oceanology
- Chinese Academy of Sciences
- Qingdao 266071
- People's Republic of China
| | - Fei Yu
- Institute for Translation Medicine
- Medical College
- Qingdao University
- Qingdao 266021
- People's Republic of China
| |
Collapse
|
23
|
Pourzal R, Lundberg HJ, Hall DJ, Jacobs JJ. What Factors Drive Taper Corrosion? J Arthroplasty 2018; 33:2707-2711. [PMID: 29705684 PMCID: PMC6103829 DOI: 10.1016/j.arth.2018.03.055] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Accepted: 03/22/2018] [Indexed: 02/01/2023] Open
Abstract
Adverse local tissue reactions to corrosion products can lead to total hip arthroplasty failure. Although this problem has been well known for more than 25 years, it has seemingly increased in frequency over the recent years. The occurrence of corrosion is multifactorial-depending on implant, patient, and surgeon factors. As of now, there is no "one-size-fits-all" solution to prevent corrosion in total hip arthroplasty devices. Thus, it is imperative to fully understand the exact mechanisms of modular junction corrosion to prevent premature implant failure. This review highlights a few key concepts that need to be explored to minimize the impact of corrosion. The key concepts include (1) the prevention of micromotion, (2) the role of implant alloy metallurgy in the corrosion process, (3) the in vivo generation of a corrosive environment, and (4) potential unanticipated problems.
Collapse
Affiliation(s)
- Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Hannah J Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Deborah J Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
24
|
Effect of simulated inflammatory conditions and potential on dissolution and surface oxide of CoCrMo alloy: In situ electrochemical atomic force microscopy study. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2017.12.151] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
25
|
Sullivan SJL, Madamba D, Sivan S, Miyashiro K, Dreher ML, Trépanier C, Nagaraja S. The effects of surface processing on in-vivo corrosion of Nitinol stents in a porcine model. Acta Biomater 2017; 62:385-396. [PMID: 28842334 DOI: 10.1016/j.actbio.2017.08.029] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2017] [Revised: 08/17/2017] [Accepted: 08/21/2017] [Indexed: 11/28/2022]
Abstract
A major limitation with current assessments of corrosion in metallic medical devices is the lack of correlation between in-vitro and in-vivo corrosion performance. Therefore, the objective of this study was to elucidate the relationship between pitting corrosion measured by breakdown potentials (Eb) in ASTM F2129 testing and corrosion resistance in-vivo. Four groups of Nitinol stents were manufactured using different processing methods to create unique surface properties. The stents were implanted into iliac arteries of minipigs for six months and explanted for corrosion analysis. Scanning electron microscopy and energy dispersive X-ray spectrometry analyses indicated that stents with a thick complex thermal oxide (420nm) and high corrosion resistance in-vitro (Eb=975±94mV) were free from detectable corrosion in-vivo and exhibited no changes in Ni/Ti ratio when compared to non-implanted controls. This result was also found in mechanically polished stents with a thin native oxide (4nm; Eb=767±226mV). In contrast, stents with a moderately thick thermal oxide (130nm) and low corrosion resistance in-vitro (Eb=111±63mV) possessed corrosion with associated surface microcracks in-vivo. In addition, Ni/Ti ratios in corroded regions were significantly lower compared to non-corroded adjacent areas on explanted stents. When stents were minimally processed (i.e. retained native tube oxide from the drawing process), a thick thermal oxide was present (399nm) with low in-vitro corrosion resistance (Eb=68±29mV) resulting in extensive in-vivo pitting. These findings demonstrate that functional corrosion testing combined with a detailed understanding of the surface characteristics of a Nitinol medical device can provide insight into in-vivo corrosion resistance. STATEMENT OF SIGNIFICANCE Nitinol is a commonly used material in the medical device industry. However, correlations between surface processing of nitinol and in-vivo corrosion has yet to be established. Elucidating the link between in-vivo corrosion and pre-clinical characterization can aid in improved prediction of clinical safety and performance of nitinol devices. We addressed this knowledge gap by fabricating nitinol stents to possess distinct surface properties and evaluating their corrosion susceptibility both in-vitro and after six months of in-vivo exposure. Relationships between stent processing, surface characterization, corrosion bench testing, and outcomes from explanted devices are discussed. These findings highlight the importance of surface characterization in nitinol devices and provide in-vitro pitting corrosion levels that can induce in-vivo corrosion in nitinol stents.
Collapse
Affiliation(s)
- Stacey J L Sullivan
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, Division of Applied Mechanics, Silver Spring, MD 20993, USA
| | | | - Shiril Sivan
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, Division of Applied Mechanics, Silver Spring, MD 20993, USA
| | | | - Maureen L Dreher
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, Division of Applied Mechanics, Silver Spring, MD 20993, USA
| | | | - Srinidhi Nagaraja
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, Division of Applied Mechanics, Silver Spring, MD 20993, USA.
| |
Collapse
|
26
|
In-situ Generated Tribomaterial in Metal/Metal Contacts: current understanding and future implications for implants. ACTA ACUST UNITED AC 2017; 10:42-50. [PMID: 28808674 DOI: 10.1016/j.biotri.2017.03.006] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Artificial hip joints operate in aqueous biofluids that are highly reactive towards metallic surfaces. The reactivity at the metal interface is enhanced by mechanical interaction due to friction, which can change the near-surface structure of the metal and surface chemistry. There are now several reports in the literature about the in-situ generation of reaction films and tribo-metallurgical transformations on metal-on-metal hip joints. This paper summarizes current knowledge and provides a mechanistic interpretation of the surface chemical and metallurgical phenomena. Basic concepts of corrosion and wear are illustrated and used to interpret available literature on in-vitro and in-vivo studies of metal-on-metal hip joints. Based on this review, three forms of tribomaterial, characterized by different combinations of oxide films and organic layers, can be determined. It is shown that the generation of these tribofilms can be related to specific electrochemical and mechanical phenomena in the metal interface. It is suggested that the generation of this surface reaction layer constitutes a way to minimize (mechanical) wear of MoM hip implants.
Collapse
|
27
|
Berni M, Marchiori G, Gambardella A, Boi M, Bianchi M, Russo A, Visani A, Marcacci M, Pavan PG, Lopomo NF. Effects of working gas pressure on zirconium dioxide thin film prepared by pulsed plasma deposition: roughness, wettability, friction and wear characteristics. J Mech Behav Biomed Mater 2017; 72:200-208. [PMID: 28500999 DOI: 10.1016/j.jmbbm.2017.05.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Revised: 04/29/2017] [Accepted: 05/03/2017] [Indexed: 11/19/2022]
Abstract
In joint arthroplasty one of the main issues related to the failure of prosthetic implants is due to the wear of the ultra-high molecular weight polyethylene (UHMWPE) component. Surface treatments and coatings have been recognized as enhancing methods, able to improve the tribological properties of the implants. Therefore, the main objective of this work was to investigate the possibility to fabricate yttria-stabilized zirconia (YSZ) coatings on a metal (AISI 316-L) substrate by means of Pulsed Electron Deposition, in order to improve the tribological behavior of the polymer-metal coupling, by reducing the initial wear of the UHMWPE component. In order to optimize the coating characteristics, the effects of working gas pressure on both its morphological and tribological properties were analyzed. Morphological characterization of the films was evaluated by Atomic Force Microscopy (AFM). Coating wettability was also estimated by contact angle (CA) measurement. Tribological performance (coupling friction and wear of UHMWPE) was evaluated by using a ball-on-disc tribometer during highly-stressing tests in dry and lubricated (i.e. NaCl and serum) conditions; friction and wear were specifically evaluated at the initial sliding distances - to highlight the main effect of coating morphology - and after 100m - where the influence of the intrinsic materials properties prevails. AFM analysis highlighted that the working pressure heavily affected the morphological characteristics of the realized films. The wettability of the coating at the highest and lowest deposition pressures (CA ~ 60°, closed to substrate value) decreased for intermediate pressures, reaching a maximum CA of ~ 90°. Regarding tribological tests, a strong correlation was found in the initial steps between friction coefficient and wettability, which decreased as the distance increased. Concerning UHMWPE wear associated to coated counterpart, at 100m a reduction rate of about 7% in dry, 12% in NaCl and 5% in presence of serum was obtained compared to the uncoated counterpart. Differently from what highlighted for friction, no correlation was found between wear rate and morphological parameters. These findings, in agreement with literature, underlined the effect of the deposition pressure on the morphological properties, but suggested that physical characteristics are influenced too. Further research on the deposition process will be required in order to improve the tribological performance of the coating at long distances, addressing - above all - orthopedic applications.
Collapse
Affiliation(s)
- M Berni
- Istituto Ortopedico Rizzoli, Laboratorio di NanoBiotecnologie - NaBi, via di Barbiano 1/10, Bologna, Italy
| | - G Marchiori
- Istituto Ortopedico Rizzoli, Laboratorio di NanoBiotecnologie - NaBi, via di Barbiano 1/10, Bologna, Italy
| | - A Gambardella
- Istituto Ortopedico Rizzoli, Laboratorio di NanoBiotecnologie - NaBi, via di Barbiano 1/10, Bologna, Italy
| | - M Boi
- Istituto Ortopedico Rizzoli, Laboratorio di NanoBiotecnologie - NaBi, via di Barbiano 1/10, Bologna, Italy
| | - M Bianchi
- Istituto Ortopedico Rizzoli, Laboratorio di NanoBiotecnologie - NaBi, via di Barbiano 1/10, Bologna, Italy
| | - A Russo
- Istituto Ortopedico Rizzoli, Laboratorio di NanoBiotecnologie - NaBi, via di Barbiano 1/10, Bologna, Italy
| | - A Visani
- Istituto Ortopedico Rizzoli, Laboratorio di Biomeccanica ed Innovazione Tecnologica, via di Barbiano 1/10, Bologna, Italy
| | - M Marcacci
- Istituto Ortopedico Rizzoli, Laboratorio di NanoBiotecnologie - NaBi, via di Barbiano 1/10, Bologna, Italy; Istituto Ortopedico Rizzoli, Laboratorio di Biomeccanica ed Innovazione Tecnologica, via di Barbiano 1/10, Bologna, Italy
| | - P G Pavan
- Dipartimento di Ingegneria Industriale, Centro Interdipartimentale di Ricerca di Meccanica dei Materiali Biologici - CMMB, Università degli Studi di Padova, Via F. Marzolo 9, Padova, Italy
| | - N F Lopomo
- Dipartimento di Ingegneria dell'Informazione, Università degli Studi di Brescia, via Branze 38, Brescia, Italy
| |
Collapse
|
28
|
Asri RIM, Harun WSW, Samykano M, Lah NAC, Ghani SAC, Tarlochan F, Raza MR. Corrosion and surface modification on biocompatible metals: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 77:1261-1274. [PMID: 28532004 DOI: 10.1016/j.msec.2017.04.102] [Citation(s) in RCA: 189] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 04/18/2017] [Indexed: 12/12/2022]
Abstract
Corrosion prevention in biomaterials has become crucial particularly to overcome inflammation and allergic reactions caused by the biomaterials' implants towards the human body. When these metal implants contacted with fluidic environments such as bloodstream and tissue of the body, most of them became mutually highly antagonistic and subsequently promotes corrosion. Biocompatible implants are typically made up of metallic, ceramic, composite and polymers. The present paper specifically focuses on biocompatible metals which favorably used as implants such as 316L stainless steel, cobalt-chromium-molybdenum, pure titanium and titanium-based alloys. This article also takes a close look at the effect of corrosion towards the implant and human body and the mechanism to improve it. Due to this corrosion delinquent, several surface modification techniques have been used to improve the corrosion behavior of biocompatible metals such as deposition of the coating, development of passivation oxide layer and ion beam surface modification. Apart from that, surface texturing methods such as plasma spraying, chemical etching, blasting, electropolishing, and laser treatment which used to improve corrosion behavior are also discussed in detail. Introduction of surface modifications to biocompatible metals is considered as a "best solution" so far to enhanced corrosion resistance performance; besides achieving superior biocompatibility and promoting osseointegration of biocompatible metals and alloys.
Collapse
Affiliation(s)
- R I M Asri
- Institute of Postgraduate Studies, Universiti Malaysia Pahang, Lebuhraya Tun Razak, Gambang, 26300 Kuantan, Pahang, Malaysia
| | - W S W Harun
- Green Research for Advanced Materials Laboratory, Human Engineering Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia.
| | - M Samykano
- Structural and Material Degradation Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
| | - N A C Lah
- Structural and Material Degradation Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
| | - S A C Ghani
- Green Research for Advanced Materials Laboratory, Human Engineering Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
| | - F Tarlochan
- Department of Mechanical and Industrial Engineering, College of Engineering, Qatar University, Doha, Qatar
| | - M R Raza
- Department of Mechanical Engineering, COMSATS Institute of Information Technology, Sahiwal 57000, Pakistan
| |
Collapse
|
29
|
Liu Y, Gilbert JL. The effect of simulated inflammatory conditions and Fenton chemistry on the electrochemistry of CoCrMo alloy. J Biomed Mater Res B Appl Biomater 2017; 106:209-220. [DOI: 10.1002/jbm.b.33830] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2016] [Revised: 10/10/2016] [Accepted: 12/01/2016] [Indexed: 12/13/2022]
Affiliation(s)
- Yangping Liu
- Syracuse Biomaterials Institute; Syracuse University; Syracuse New York 13244
- Department of Biomedical and Chemical Engineering; Syracuse University; Syracuse New York 13244
| | - Jeremy L. Gilbert
- Syracuse Biomaterials Institute; Syracuse University; Syracuse New York 13244
- Department of Biomedical and Chemical Engineering; Syracuse University; Syracuse New York 13244
| |
Collapse
|
30
|
Berni M, Lopomo N, Marchiori G, Gambardella A, Boi M, Bianchi M, Visani A, Pavan P, Russo A, Marcacci M. Tribological characterization of zirconia coatings deposited on Ti6Al4V components for orthopedic applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 62:643-55. [PMID: 26952468 DOI: 10.1016/j.msec.2016.02.014] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Revised: 01/15/2016] [Accepted: 02/03/2016] [Indexed: 11/17/2022]
Abstract
One of the most important issues leading to the failure of total joint arthroplasty is related to the wear of the plastic components, which are generally made of ultra high molecular weight polyethylene (UHMWPE). Therefore, the reduction of joint wear represents one of the main challenges the research in orthopedics is called to address nowadays. Surface treatments and coatings have been recognized as innovative methods to improve tribological properties, also in the orthopedic field. This work investigated the possibility to realize hard ceramic coatings on the metal component of a prosthesis, by means of Pulsed Plasma Deposition, in order to reduce friction and wear in the standard coupling against UHMWPE. Ti6Al4V substrates were coated with a 2 μm thick yttria-stabilized zirconia (YSZ) layer. The mechanical properties of the YSZ coatings were assessed by nanoindentation tests performed on flat Ti6Al4V substrates. Tribological performance was evaluated using a ball-on-disk tribometer in dry and lubricated (i.e. with fetal bovine serum) highly-stressing conditions, up to an overall distance of 10 km. Tribology was characterized in terms of coefficient of friction (CoF) and wear rate of the UHMWPE disk. After testing, specimens were analyzed through optical microscopy and SEM images, in order to check the wear degradation mechanisms. Progressive loading scratch tests were also performed in dry and wet conditions to determine the effects of the environment on the adhesion of the coating. Our results supported the beneficial effect of YSZ coating on metal components. In particular, the proposed solution significantly reduced UHMWPE wear rate and friction. At 10 km of sliding distance, a wear rate reduction of about 18% in dry configuration and of 4% in presence of serum, was obtained by the coated group compared to the uncoated group. As far as friction in dry condition is concerned, the coating allowed to maintain low CoF values until the end of the tests, with an overall difference of about 40% compared to the uncoated balls. In wet conditions, the friction values were found to be comparable between coated and uncoated materials, mainly due to a premature delamination of the coating. Scratch tests in wet showed in fact a reduction of the critical load required to a complete delamination due to a formation of blister, although no change or damage occurred at the coating during the soaking period. Although conditions of high values of contact pressure were considered, further analyses are however required to fully understand the behavior of YSZ coatings in wet environment and additional research on the deposition process will be mandatory in order to improve the coating tribological performance at long distances addressing orthopedic applications.
Collapse
Affiliation(s)
- M Berni
- Laboratorio di NanoBiotecnologie - NaBi, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy.
| | - N Lopomo
- Laboratorio di Biomeccanica ed Innovazione Tecnologica, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy; Dipartimento di Ingegneria dell'Informazione, Università degli Studi di Brescia, via Branze 38, Brescia, Italy
| | - G Marchiori
- Laboratorio di NanoBiotecnologie - NaBi, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy
| | - A Gambardella
- Laboratorio di NanoBiotecnologie - NaBi, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy
| | - M Boi
- Laboratorio di NanoBiotecnologie - NaBi, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy
| | - M Bianchi
- Laboratorio di NanoBiotecnologie - NaBi, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy
| | - A Visani
- Laboratorio di Biomeccanica ed Innovazione Tecnologica, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy
| | - P Pavan
- Dipartimento di Ingegneria Industriale, Centro Interdipartimentale di Ricerca di Meccanica dei Materiali Biologici - CMMB, Università di Padova, Via F. Marzolo 9, Padova 35131, Italy
| | - A Russo
- Laboratorio di NanoBiotecnologie - NaBi, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy
| | - M Marcacci
- Laboratorio di NanoBiotecnologie - NaBi, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy; Laboratorio di Biomeccanica ed Innovazione Tecnologica, Istituto Ortopedico Rizzoli, via di Barbiano 1/10, Bologna, Italy
| |
Collapse
|
31
|
Muruve NG, Cheng YF, Feng Y, Liu T, Muruve DA, Hassett DJ, Irvin RT. Peptide-based biocoatings for corrosion protection of stainless steel biomaterial in a chloride solution. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 68:695-700. [DOI: 10.1016/j.msec.2016.06.053] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Revised: 05/20/2016] [Accepted: 06/14/2016] [Indexed: 11/16/2022]
|
32
|
Scholl L, Schmidig G, Faizan A, TenHuisen K, Nevelos J. Evaluation of surgical impaction technique and how it affects locking strength of the head-stem taper junction. Proc Inst Mech Eng H 2016; 230:661-7. [PMID: 27107031 DOI: 10.1177/0954411916644477] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Accepted: 03/22/2016] [Indexed: 11/17/2022]
Abstract
Cases of fretting and corrosion at the taper junction have been reported in large metal-on-metal bearing combinations, and more recently, this concern has included metal-on-polyethylene bearing combinations. Many of these patients have been revised due to adverse local tissue reaction secondary to taper corrosion. This taper corrosion-related adverse local tissue reaction seems to be a multifactorial issue and difficult to assess. The aim of this study was to look at one potential variable, the impaction behavior (impaction force, number of blows, etc.) of orthopedic surgeons, and understand how this can affect the locking strength of tapers. A group of experienced orthopedic surgeons were asked to use their typical surgical approach to impact a femoral head onto a hip femoral stem using an Operating Room (OR)-simulated test setup. Impaction parameters such as impaction force, velocity, and energy, as well as the number of impacts, were characterized and applied in a bench-top study used to evaluate the effect of these parameters on the initial stability of the taper junction. High variation was found in the surgical impaction parameters, but overall it was determined that increased impaction force correlated to superior stability of the taper junction.
Collapse
|
33
|
Doi K, Miyabe S, Tsuchiya H, Fujimoto S. Degradation of Ti-6Al-4V alloy under cyclic loading in a simulated body environment with cell culturing. J Mech Behav Biomed Mater 2015; 56:6-13. [PMID: 26651063 DOI: 10.1016/j.jmbbm.2015.10.032] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Revised: 10/29/2015] [Accepted: 10/31/2015] [Indexed: 11/28/2022]
Abstract
The present study reports the corrosion fatigue of the Ti-6Al-4V alloy using cyclic deformation test in a simulated body fluid under cell culturing for the first time. Cyclic deformation tests were carried out using three types of specimens to reveal the effects of proteins and cells on the corrosion fatigue of the alloy. For the 1-day-immersed and 1-week-immersed specimens, tensile specimens were soaked in a simulated body fluid for 1 day and 1 week, respectively, before cyclic deformation test, whereas for the cell-cultured specimen, MC3T3-E1 osteoblast-like cells were seeded and then cultured on tensile specimens for 1 week. The incubation period for crack initiation was longer for the cell-cultured and 1-week-immersed specimens compared to that for the 1-day-immersed specimen. On the other hand, crack propagation period for the cell-cultured and 1-week-immersed specimens was shorter than that for the 1-day-immersed specimen. These results indicate that proteins and cells adhered on the alloy surface inhibit metal dissolution at newly created surface emerged by cyclic deformation to suppress crack initiation, whereas they accelerate crack propagation because dissolution at crack tip is accelerated in the occluded space formed under proteins and cells.
Collapse
Affiliation(s)
- Kotaro Doi
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan
| | - Sayaka Miyabe
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan
| | - Hiroaki Tsuchiya
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan
| | - Shinji Fujimoto
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan.
| |
Collapse
|