1
|
Zhai Y, Sun Z, Zhang T, Zhou C, Kong X. Mechanical Property of Thermoplastic Polyurethane Vascular Stents Fabricated by Fused Filament Fabrication. MICROMACHINES 2024; 15:1266. [PMID: 39459140 PMCID: PMC11509589 DOI: 10.3390/mi15101266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 10/12/2024] [Accepted: 10/15/2024] [Indexed: 10/28/2024]
Abstract
Vascular stents have many applications in treating arterial stenosis and other vascular-related diseases. The ideal vascular stent for clinical application should have radial support and axial bending mechanical properties that meet the requirements of vascular deformation coordination. The materials used for vascular stents implanted in the human body should have corresponding biocompatibility to ensure that the stents do not cause coagulation, hemolysis, and other reactions in the blood. This study fabricated four types of vascular stents, including inner hexagon, arrowhead, quadrilateral, and outer hexagonal, using fused filament fabrication technology and thermoplastic polyurethane (TPU) as materials. By evaluating the effects of edge width and wall thickness on the radial support and axial bending performance, it was found that the inner hexagonal stent exhibited the best radial support and axial bending performance under the same conditions. The design and fabrication of vascular stents based on 3D printing technology have promising application prospects in personalized customized vascular repair therapy.
Collapse
Affiliation(s)
- Yun Zhai
- School of Mechanical Engineering, Dalian Jiaotong University, Dalian 116028, China; (Y.Z.)
| | - Zezhi Sun
- School of Mechanical Engineering, Dalian Jiaotong University, Dalian 116028, China; (Y.Z.)
| | - Tie Zhang
- School of Mechanical Engineering, Dalian Jiaotong University, Dalian 116028, China; (Y.Z.)
| | - Changchun Zhou
- National Engineering Research Centre for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610065, China;
| | - Xiangpeng Kong
- Department of Cardiology, The Second Hospital of Dalian Medical University, Dalian 116023, China
| |
Collapse
|
2
|
Robinson A, Nkansah A, Bhat S, Karnik S, Jones S, Fairley A, Leung J, Wancura M, Sacks MS, Dasi LP, Cosgriff-Hernandez E. Hydrogel-polyurethane fiber composites with enhanced microarchitectural control for heart valve replacement. J Biomed Mater Res A 2024; 112:586-599. [PMID: 38018452 DOI: 10.1002/jbm.a.37641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 09/22/2023] [Accepted: 10/24/2023] [Indexed: 11/30/2023]
Abstract
Polymeric heart valves offer the potential to overcome the limited durability of tissue based bioprosthetic valves and the need for anticoagulant therapy of mechanical valve replacement options. However, developing a single-phase material with requisite biological properties and target mechanical properties remains a challenge. In this study, a composite heart valve material was developed where an electrospun mesh provides tunable mechanical properties and a hydrogel coating confers an antifouling surface for thromboresistance. Key biological responses were evaluated in comparison to glutaraldehyde-fixed pericardium. Platelet and bacterial attachment were reduced by 38% and 98%, respectively, as compared to pericardium that demonstrated the antifouling nature of the hydrogel coating. There was also a notable reduction (59%) in the calcification of the composite material as compared to pericardium. A custom 3D-printed hydrogel coating setup was developed to make valve composites for device-level hemodynamic testing. Regurgitation fraction (9.6 ± 1.8%) and effective orifice area (1.52 ± 0.34 cm2 ) met ISO 5840-2:2021 requirements. Additionally, the mean pressure gradient was comparable to current clinical bioprosthetic heart valves demonstrating preliminary efficacy. Although the hemodynamic properties are promising, it is anticipated that the random microarchitecture will result in suboptimal strain fields and peak stresses that may accelerate leaflet fatigue and degeneration. Previous computational work has demonstrated that bioinspired fiber microarchitectures can improve strain homogeneity of valve materials toward improving durability. To this end, we developed advanced electrospinning methodologies to achieve polyurethane fiber microarchitectures that mimic or exceed the physiological ranges of alignment, tortuosity, and curvilinearity present in the native valve. Control of fiber alignment from a random fiber orientation at a normalized orientation index (NOI) 14.2 ± 6.9% to highly aligned fibers at a NOI of 85.1 ± 1.4%. was achieved through increasing mandrel rotational velocity. Fiber tortuosity and curvilinearity in the range of native valve features were introduced through a post-spinning annealing process and fiber collection on a conical mandrel geometry, respectively. Overall, these studies demonstrate the potential of hydrogel-polyurethane fiber composite as a heart valve material. Future studies will utilize the developed advanced electrospinning methodologies in combination with model-directed fabrication toward optimizing durability as a function of fiber microarchitecture.
Collapse
Affiliation(s)
- Andrew Robinson
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, USA
| | - Abbey Nkansah
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, USA
| | - Sanchita Bhat
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Shweta Karnik
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Sarah Jones
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, USA
| | - Ashauntee Fairley
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, USA
| | - Jonathan Leung
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, USA
| | - Megan Wancura
- Department of Chemistry, The University of Texas at Austin, Austin, Texas, USA
| | - Michael S Sacks
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, USA
- James T. Willerson Center for Cardiovascular Modeling and Simulation, The Oden Institute for Computational Engineering and Sciences, Austin, Texas, USA
- Department of Mechanical Engineering, The University of Texas at Austin, Austin, Texas, USA
| | - Lakshmi Prasad Dasi
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | | |
Collapse
|
3
|
Schoenborn S, Lorenz T, Kuo K, Fletcher DF, Woodruff MA, Pirola S, Allenby MC. Fluid-structure interactions of peripheral arteries using a coupled in silico and in vitro approach. Comput Biol Med 2023; 165:107474. [PMID: 37703711 DOI: 10.1016/j.compbiomed.2023.107474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 08/21/2023] [Accepted: 09/04/2023] [Indexed: 09/15/2023]
Abstract
Vascular compliance is considered both a cause and a consequence of cardiovascular disease and a significant factor in the mid- and long-term patency of vascular grafts. However, the biomechanical effects of localised changes in compliance cannot be satisfactorily studied with the available medical imaging technologies or surgical simulation materials. To address this unmet need, we developed a coupled silico-vitro platform which allows for the validation of numerical fluid-structure interaction results as a numerical model and physical prototype. This numerical one-way and two-way fluid-structure interaction study is based on a three-dimensional computer model of an idealised femoral artery which is validated against patient measurements derived from the literature. The numerical results are then compared with experimental values collected from compliant arterial phantoms via direct pressurisation and ring tensile testing. Phantoms within a compliance range of 1.4-68.0%/100 mmHg were fabricated via additive manufacturing and silicone casting, then mechanically characterised via ring tensile testing and optical analysis under direct pressurisation with moderately statistically significant differences in measured compliance ranging between 10 and 20% for the two methods. One-way fluid-structure interaction coupling underestimated arterial wall compliance by up to 14.7% compared with two-way coupled models. Overall, Solaris™ (Smooth-On) matched the compliance range of the numerical and in vivo patient models most closely out of the tested silicone materials. Our approach is promising for vascular applications where mechanical compliance is especially important, such as the study of diseases which commonly affect arterial wall stiffness, such as atherosclerosis, and the model-based design, surgical training, and optimisation of vascular prostheses.
Collapse
Affiliation(s)
- S Schoenborn
- BioMimetic Systems Engineering (BMSE) Lab, School of Chemical Engineering, University of Queensland (UQ), St Lucia, QLD, 4072, Australia; Biofabrication and Tissue Morphology (BTM) Group, Faculty of Engineering, Centre for Biomedical Technologies, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia
| | - T Lorenz
- Institute of Textile Technology, RWTH Aachen University, 52074, Aachen, Germany
| | - K Kuo
- Institute of Textile Technology, RWTH Aachen University, 52074, Aachen, Germany
| | - D F Fletcher
- School of Chemical and Biomolecular Engineering, University of Sydney, Darlington, NSW, 2006, Australia
| | - M A Woodruff
- Biofabrication and Tissue Morphology (BTM) Group, Faculty of Engineering, Centre for Biomedical Technologies, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia
| | - S Pirola
- BHF Centre of Research Excellence, Faculty of Medicine, Institute of Clinical Sciences, Imperial College London, South Kensington Campus, London, SW7 2AZ, United Kingdom; Department of Biomechanical Engineering, Faculty of Mechanical Engineering (3me), Delft University of Technology (TUD), Delft, the Netherlands
| | - M C Allenby
- BioMimetic Systems Engineering (BMSE) Lab, School of Chemical Engineering, University of Queensland (UQ), St Lucia, QLD, 4072, Australia; Biofabrication and Tissue Morphology (BTM) Group, Faculty of Engineering, Centre for Biomedical Technologies, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia.
| |
Collapse
|
4
|
Roberts EL, Abdollahi S, Oustadi F, Stephens ED, Badv M. Bacterial-Nanocellulose-Based Biointerfaces and Biomimetic Constructs for Blood-Contacting Medical Applications. ACS MATERIALS AU 2023; 3:418-441. [PMID: 38089096 PMCID: PMC10510515 DOI: 10.1021/acsmaterialsau.3c00021] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 06/08/2023] [Accepted: 06/09/2023] [Indexed: 10/12/2024]
Abstract
Understanding the interaction between biomaterials and blood is critical in the design of novel biomaterials for use in biomedical applications. Depending on the application, biomaterials can be designed to promote hemostasis, slow or stop bleeding in an internal or external wound, or prevent thrombosis for use in permanent or temporary medical implants. Bacterial nanocellulose (BNC) is a natural, biocompatible biopolymer that has recently gained interest for its potential use in blood-contacting biomedical applications (e.g., artificial vascular grafts), due to its high porosity, shapeability, and tissue-like properties. To promote hemostasis, BNC has been modified through oxidation or functionalization with various peptides, proteins, polysaccharides, and minerals that interact with the coagulation cascade. For use as an artificial vascular graft or to promote vascularization, BNC has been extensively researched, with studies investigating different modification techniques to enhance endothelialization such as functionalizing with adhesion peptides or extracellular matrix (ECM) proteins as well as tuning the structural properties of BNC such as surface roughness, pore size, and fiber size. While BNC inherently exhibits comparable mechanical characteristics to endogenous blood vessels, these mechanical properties can be enhanced through chemical functionalization or through altering the fabrication method. In this review, we provide a comprehensive overview of the various modification techniques that have been implemented to enhance the suitability of BNC for blood-contacting biomedical applications and different testing techniques that can be applied to evaluate their performance. Initially, we focused on the modification techniques that have been applied to BNC for hemostatic applications. Subsequently, we outline the different methods used for the production of BNC-based artificial vascular grafts and to generate vasculature in tissue engineered constructs. This sequential organization enables a clear and concise discussion of the various modifications of BNC for different blood-contacting biomedical applications and highlights the diverse and versatile nature of BNC as a natural biomaterial.
Collapse
Affiliation(s)
- Erin L. Roberts
- Department
of Biomedical Engineering, Schulich School of Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta, Canada, T2N 1N4
| | - Sorosh Abdollahi
- Department
of Biomedical Engineering, Schulich School of Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta, Canada, T2N 1N4
| | - Fereshteh Oustadi
- Department
of Biomedical Engineering, Schulich School of Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta, Canada, T2N 1N4
| | - Emma D. Stephens
- Department
of Biomedical Engineering, Schulich School of Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta, Canada, T2N 1N4
| | - Maryam Badv
- Department
of Biomedical Engineering, Schulich School of Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta, Canada, T2N 1N4
- Libin
Cardiovascular Institute, University of
Calgary, 3330 Hospital
Drive NW, Calgary, Alberta, Canada, T2N 4N1
| |
Collapse
|
5
|
Wonski BT, Fisher B, Lam MT. Hydrogel Coating Optimization to Augment Engineered Soft Tissue Mechanics in Tissue-Engineered Blood Vessels. Bioengineering (Basel) 2023; 10:780. [PMID: 37508807 PMCID: PMC10376319 DOI: 10.3390/bioengineering10070780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 06/24/2023] [Accepted: 06/27/2023] [Indexed: 07/30/2023] Open
Abstract
Tissue engineering has the advantage of replicating soft tissue mechanics to better simulate and integrate into native soft tissue. However, soft tissue engineering has been fraught with issues of insufficient tissue strength to withstand physiological mechanical requirements. This factor is due to the lack of strength inherent in cell-only constructs and in the biomaterials used for soft tissue engineering and limited extracellular matrix (ECM) production possible in cell culture. To address this issue, we explored the use of an ECM-based hydrogel coating to serve as an adhesive tool, as demonstrated in vascular tissue engineering. The efficacy of cells to supplement mechanical strength in the coating was explored. Specifically, selected coatings were applied to an engineered artery tunica adventitia to accurately test their properties in a natural tissue support structure. Multiple iterations of three primary hydrogels with and without cells were tested: fibrin, collagen, and gelatin hydrogels with and without fibroblasts. The effectiveness of a natural crosslinker to further stabilize and strengthen the hydrogels was investigated, namely genipin extracted from the gardenia fruit. We found that gelatin crosslinked with genipin alone exhibited the highest tensile strength; however, fibrin gel supported cell viability the most. Overall, fibrin gel coating without genipin was deemed optimal for its balance in increasing mechanical strength while still supporting cell viability and was used in the final mechanical and hydrodynamic testing assessments. Engineered vessels coated in fibrin hydrogel with cells resulted in the highest tensile strength of all hydrogel-coated groups after 14 d in culture, demonstrating a tensile strength of 11.9 ± 2.91 kPa, compared to 5.67 ± 1.37 kPa for the next highest collagen hydrogel group. The effect of the fibrin hydrogel coating on burst pressure was tested on our strongest vessels composed of human aortic smooth muscle cells. A significant increase from our previously reported burst pressure of 51.3 ± 2.19 mmHg to 229 ± 23.8 mmHg was observed; however, more work is needed to render these vessels compliant with mechanical and biological criteria for blood vessel substitutes.
Collapse
Affiliation(s)
- Bryan T. Wonski
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
| | - Bruce Fisher
- Plymouth Family Dentistry, Plymouth, MI 48170, USA
| | - Mai T. Lam
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
| |
Collapse
|
6
|
Rovas G, Bikia V, Stergiopulos N. Design and computational optimization of compliance-matching aortic grafts. Front Bioeng Biotechnol 2023; 11:1179174. [PMID: 37456727 PMCID: PMC10341153 DOI: 10.3389/fbioe.2023.1179174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 06/19/2023] [Indexed: 07/18/2023] Open
Abstract
Introduction: Synthetic vascular grafts have been widely used in clinical practice for aortic replacement surgery. Despite their high rates of surgical success, they remain significantly less compliant than the native aorta, resulting in a phenomenon called compliance mismatch. This incompatibility of elastic properties may cause serious post-operative complications, including hypertension and myocardial hypertrophy. Methods: To mitigate the risk for these complications, we designed a multi-layer compliance-matching stent-graft, that we optimized computationally using finite element analysis, and subsequently evaluated in vitro. Results: We found that our compliance-matching grafts attained the distensibility of healthy human aortas, including those of young adults, thereby significantly exceeding the distensibility of gold-standard grafts. The compliant grafts maintained their properties in a wide range of conditions that are expected after the implantation. Furthermore, the computational model predicted the graft radius with enough accuracy to allow computational optimization to be performed effectively. Conclusion: Compliance-matching grafts may offer a valuable improvement over existing prostheses and they could potentially mitigate the risk for post-operative complications attributed to excessive graft stiffness.
Collapse
|
7
|
Johnston A, Callanan A. Recent Methods for Modifying Mechanical Properties of Tissue-Engineered Scaffolds for Clinical Applications. Biomimetics (Basel) 2023; 8:205. [PMID: 37218791 PMCID: PMC10204517 DOI: 10.3390/biomimetics8020205] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/03/2023] [Accepted: 05/12/2023] [Indexed: 05/24/2023] Open
Abstract
The limited regenerative capacity of the human body, in conjunction with a shortage of healthy autologous tissue, has created an urgent need for alternative grafting materials. A potential solution is a tissue-engineered graft, a construct which supports and integrates with host tissue. One of the key challenges in fabricating a tissue-engineered graft is achieving mechanical compatibility with the graft site; a disparity in these properties can shape the behaviour of the surrounding native tissue, contributing to the likelihood of graft failure. The purpose of this review is to examine the means by which researchers have altered the mechanical properties of tissue-engineered constructs via hybrid material usage, multi-layer scaffold designs, and surface modifications. A subset of these studies which has investigated the function of their constructs in vivo is also presented, followed by an examination of various tissue-engineered designs which have been clinically translated.
Collapse
Affiliation(s)
| | - Anthony Callanan
- Institute for Bioengineering, School of Engineering, University of Edinburgh, Edinburgh EH9 3DW, UK;
| |
Collapse
|
8
|
Yao Y, Pohan G, Cutiongco MFA, Jeong Y, Kunihiro J, Zaw AM, David D, Shangguan H, Yu ACH, Yim EKF. In vivo evaluation of compliance mismatch on intimal hyperplasia formation in small diameter vascular grafts. Biomater Sci 2023; 11:3297-3307. [PMID: 36943136 PMCID: PMC10160004 DOI: 10.1039/d3bm00167a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/23/2023]
Abstract
Small diameter synthetic vascular grafts have high failure rate due to the thrombosis and intimal hyperplasia formation. Compliance mismatch between the synthetic graft and native artery has been speculated to be one of the main causes of intimal hyperplasia. However, changing the compliance of synthetic materials without altering material chemistry remains a challenge. Here, we used poly(vinyl alcohol) (PVA) hydrogel as a graft material due to its biocompatibility and tunable mechanical properties to investigate the role of graft compliance in the development of intimal hyperplasia and in vivo patency. Two groups of PVA small diameter grafts with low compliance and high compliance were fabricated by dip casting method and implanted in a rabbit carotid artery end-to-side anastomosis model for 4 weeks. We demonstrated that the grafts with compliance that more closely matched with rabbit carotid artery had lower anastomotic intimal hyperplasia formation and higher graft patency compared to low compliance grafts. Overall, this study suggested that reducing the compliance mismatch between the native artery and vascular grafts is beneficial for reducing intimal hyperplasia formation.
Collapse
Affiliation(s)
- Yuan Yao
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1.
| | - Grace Pohan
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1.
| | - Marie F A Cutiongco
- Mechanobiology Institute, National University of Singapore, 9 Engineering Drive 1, Singapore 117575
- Division of Cell Matrix Biology and Regenerative Medicine, The University of Manchester, Oxford Road, Manchester, UK M13 9PL
| | - YeJin Jeong
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1.
| | - Joshua Kunihiro
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1.
| | - Aung Moe Zaw
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1.
| | - Dency David
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1.
| | - Hanyue Shangguan
- Schlegel Research Institute for Aging, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1
- Center for Biotechnology and Bioengineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1
| | - Alfred C H Yu
- Schlegel Research Institute for Aging, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1
- Center for Biotechnology and Bioengineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1
| | - Evelyn K F Yim
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1.
- Mechanobiology Institute, National University of Singapore, 9 Engineering Drive 1, Singapore 117575
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1
- Center for Biotechnology and Bioengineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1
| |
Collapse
|
9
|
Yao Y, Zaw AM, Anderson DE, Jeong Y, Kunihiro J, Hinds MT, Yim EK. Fucoidan and topography modification improved in situ endothelialization on acellular synthetic vascular grafts. Bioact Mater 2023; 22:535-550. [PMID: 36330164 PMCID: PMC9619221 DOI: 10.1016/j.bioactmat.2022.10.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Revised: 09/20/2022] [Accepted: 10/09/2022] [Indexed: 11/13/2022] Open
Abstract
Thrombogenesis remains the primary failure of synthetic vascular grafts. Endothelial coverage is crucial to provide an antithrombogenic surface. However, most synthetic materials do not support cell adhesion, and transanastomotic endothelial migration is limited. Here, a surface modification strategy using fucoidan and topography was developed to enable fast in situ endothelialization of polyvinyl alcohol, which is not endothelial cell-adhesive. Among three different immobilization approaches compared, conjugation of aminated-fucoidan promoted endothelial monolayer formation while minimizing thrombogenicity in both in vitro platelet rich plasma testing and ex vivo non-human primate shunt assay. Screening of six topographical patterns showed that 2 μm gratings increased endothelial cell migration without inducing inflammation responses of endothelial cells. Mechanistic studies demonstrated that fucoidan could attract fibronectin, enabling integrin binding and focal adhesion formation and activating focal adhesion kinase (FAK) signaling, and 2 μm gratings further enhanced FAK-mediated cell migration. In a clinically relevant rabbit carotid artery end-to-side anastomosis model, 60% in situ endothelialization was observed throughout the entire lumen of 1.7 mm inner diameter modified grafts, compared to 0% of unmodified graft, and the four-week graft patency also increased. This work presents a promising strategy to stimulate in situ endothelialization on synthetic materials for improving long-term performance.
Collapse
Affiliation(s)
- Yuan Yao
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Aung Moe Zaw
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Deirdre E.J. Anderson
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, 97239, USA
| | - YeJin Jeong
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Joshua Kunihiro
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Monica T. Hinds
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Evelyn K.F. Yim
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
- Center for Biotechnology and Bioengineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
10
|
Yang GH, Kang D, An S, Ryu JY, Lee K, Kim JS, Song MY, Kim YS, Kwon SM, Jung WK, Jeong W, Jeon H. Advances in the development of tubular structures using extrusion-based 3D cell-printing technology for vascular tissue regenerative applications. Biomater Res 2022; 26:73. [PMID: 36471437 PMCID: PMC9720982 DOI: 10.1186/s40824-022-00321-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 11/13/2022] [Indexed: 12/11/2022] Open
Abstract
Until recent, there are no ideal small diameter vascular grafts available on the market. Most of the commercialized vascular grafts are used for medium to large-sized blood vessels. As a solution, vascular tissue engineering has been introduced and shown promising outcomes. Despite these optimistic results, there are limitations to commercialization. This review will cover the need for extrusion-based 3D cell-printing technique capable of mimicking the natural structure of the blood vessel. First, we will highlight the physiological structure of the blood vessel as well as the requirements for an ideal vascular graft. Then, the essential factors of 3D cell-printing including bioink, and cell-printing system will be discussed. Afterwards, we will mention their applications in the fabrication of tissue engineered vascular grafts. Finally, conclusions and future perspectives will be discussed.
Collapse
Affiliation(s)
- Gi Hoon Yang
- Research Institute of Additive Manufacturing and Regenerative Medicine, Baobab Healthcare Inc, 55 Hanyangdaehak-Ro, Ansan, Gyeonggi-Do 15588 South Korea
| | - Donggu Kang
- Research Institute of Additive Manufacturing and Regenerative Medicine, Baobab Healthcare Inc, 55 Hanyangdaehak-Ro, Ansan, Gyeonggi-Do 15588 South Korea
| | - SangHyun An
- Preclinical Research Center, K Medi-hub, 80 Cheombok-ro, Dong-gu, Daegu, 41061 South Korea
| | - Jeong Yeop Ryu
- grid.258803.40000 0001 0661 1556Department of Plastic and Reconstructive Surgery, School of Medicine, Kyungpook National University, 130 Dongdeok‑ro, Jung‑gu, Daegu, 41944 South Korea
| | - KyoungHo Lee
- Preclinical Research Center, K Medi-hub, 80 Cheombok-ro, Dong-gu, Daegu, 41061 South Korea
| | - Jun Sik Kim
- Preclinical Research Center, K Medi-hub, 80 Cheombok-ro, Dong-gu, Daegu, 41061 South Korea
| | - Moon-Yong Song
- Medical Safety Center, Bio Division, Korea Conformity Laboratories 8, Gaetbeol-ro 145beon-gil, Yeonsu-gu, Incheon, 21999 South Korea
| | - Young-Sik Kim
- Medical Safety Center, Bio Division, Korea Conformity Laboratories 8, Gaetbeol-ro 145beon-gil, Yeonsu-gu, Incheon, 21999 South Korea
| | - Sang-Mo Kwon
- grid.262229.f0000 0001 0719 8572Department of Physiology, School of Medicine, Laboratory for Vascular Medicine and Stem Cell Biology, Medical Research Institute, Immunoregulatory Therapeutics Group in Brain Busan 21 Project, Pusan National University, Yangsan, 626-870 South Korea
| | - Won-Kyo Jung
- grid.412576.30000 0001 0719 8994Division of Biomedical Engineering and Research Center for Marine Integrated Bionics Technology, Pukyong National University, Daeyeon-dong, Nam-gu, Busan, 48513 South Korea
| | - Woonhyeok Jeong
- grid.412091.f0000 0001 0669 3109Department of Plastic and Reconstructive Surgery, Dongsan Medical Center, Keimyung University College of Medicine, 1035 Dalgubeol-daero, Dalseo-gu, Daegu, 42601 South Korea
| | - Hojun Jeon
- Research Institute of Additive Manufacturing and Regenerative Medicine, Baobab Healthcare Inc, 55 Hanyangdaehak-Ro, Ansan, Gyeonggi-Do 15588 South Korea
| |
Collapse
|
11
|
Ozdemir S, Yalcin-Enis I, Yalcinkaya B, Yalcinkaya F. An Investigation of the Constructional Design Components Affecting the Mechanical Response and Cellular Activity of Electrospun Vascular Grafts. MEMBRANES 2022; 12:929. [PMID: 36295688 PMCID: PMC9607146 DOI: 10.3390/membranes12100929] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 09/20/2022] [Accepted: 09/22/2022] [Indexed: 06/16/2023]
Abstract
Cardiovascular disease is anticipated to remain the leading cause of death globally. Due to the current problems connected with using autologous arteries for bypass surgery, researchers are developing tissue-engineered vascular grafts (TEVGs). The major goal of vascular tissue engineering is to construct prostheses that closely resemble native blood vessels in terms of morphological, mechanical, and biological features so that these scaffolds can satisfy the functional requirements of the native tissue. In this setting, morphology and cellular investigation are usually prioritized, while mechanical qualities are generally addressed superficially. However, producing grafts with good mechanical properties similar to native vessels is crucial for enhancing the clinical performance of vascular grafts, exposing physiological forces, and preventing graft failure caused by intimal hyperplasia, thrombosis, aneurysm, blood leakage, and occlusion. The scaffold's design and composition play a significant role in determining its mechanical characteristics, including suturability, compliance, tensile strength, burst pressure, and blood permeability. Electrospun prostheses offer various models that can be customized to resemble the extracellular matrix. This review aims to provide a comprehensive and comparative review of recent studies on the mechanical properties of fibrous vascular grafts, emphasizing the influence of structural parameters on mechanical behavior. Additionally, this review provides an overview of permeability and cell growth in electrospun membranes for vascular grafts. This work intends to shed light on the design parameters required to maintain the mechanical stability of vascular grafts placed in the body to produce a temporary backbone and to be biodegraded when necessary, allowing an autologous vessel to take its place.
Collapse
Affiliation(s)
- Suzan Ozdemir
- Textile Engineering Department, Textile Technologies and Design Faculty, Istanbul Technical University, Beyoglu, 34467 Istanbul, Turkey
| | - Ipek Yalcin-Enis
- Textile Engineering Department, Textile Technologies and Design Faculty, Istanbul Technical University, Beyoglu, 34467 Istanbul, Turkey
| | - Baturalp Yalcinkaya
- Department of Material Science, Faculty of Mechanical Engineering, Technical University of Liberec, 461 17 Liberec, Czech Republic
| | - Fatma Yalcinkaya
- Department of Environmental Technology, Institute for Nanomaterials, Advanced Technologies and Innovations, Technical University of Liberec, 461 17 Liberec, Czech Republic
| |
Collapse
|
12
|
Yi B, Xu Q, Liu W. An overview of substrate stiffness guided cellular response and its applications in tissue regeneration. Bioact Mater 2022; 15:82-102. [PMID: 35386347 PMCID: PMC8940767 DOI: 10.1016/j.bioactmat.2021.12.005] [Citation(s) in RCA: 81] [Impact Index Per Article: 40.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 12/03/2021] [Accepted: 12/03/2021] [Indexed: 02/06/2023] Open
Abstract
Cell-matrix interactions play a critical role in tissue repair and regeneration. With gradual uncovering of substrate mechanical characteristics that can affect cell-matrix interactions, much progress has been made to unravel substrate stiffness-mediated cellular response as well as its underlying mechanisms. Yet, as a part of cell-matrix interaction biology, this field remains in its infancy, and the detailed molecular mechanisms are still elusive regarding scaffold-modulated tissue regeneration. This review provides an overview of recent progress in the area of the substrate stiffness-mediated cellular responses, including 1) the physical determination of substrate stiffness on cell fate and tissue development; 2) the current exploited approaches to manipulate the stiffness of scaffolds; 3) the progress of recent researches to reveal the role of substrate stiffness in cellular responses in some representative tissue-engineered regeneration varying from stiff tissue to soft tissue. This article aims to provide an up-to-date overview of cell mechanobiology research in substrate stiffness mediated cellular response and tissue regeneration with insightful information to facilitate interdisciplinary knowledge transfer and enable the establishment of prognostic markers for the design of suitable biomaterials. Substrate stiffness physically determines cell fate and tissue development. Rational design of scaffolds requires the understanding of cell-matrix interactions. Substrate stiffness depends on scaffold molecular-constituent-structure interaction. Substrate stiffness-mediated cellular responses vary in different tissues.
Collapse
|
13
|
Small Diameter Cell-Free Tissue-Engineered Vascular Grafts: Biomaterials and Manufacture Techniques to Reach Suitable Mechanical Properties. Polymers (Basel) 2022; 14:polym14173440. [PMID: 36080517 PMCID: PMC9460130 DOI: 10.3390/polym14173440] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 07/06/2022] [Accepted: 07/06/2022] [Indexed: 12/25/2022] Open
Abstract
Vascular grafts (VGs) are medical devices intended to replace the function of a blood vessel. Available VGs in the market present low patency rates for small diameter applications setting the VG failure. This event arises from the inadequate response of the cells interacting with the biomaterial in the context of operative conditions generating chronic inflammation and a lack of regenerative signals where stenosis or aneurysms can occur. Tissue Engineered Vascular grafts (TEVGs) aim to induce the regeneration of the native vessel to overcome these limitations. Besides the biochemical stimuli, the biomaterial and the particular micro and macrostructure of the graft will determine the specific behavior under pulsatile pressure. The TEVG must support blood flow withstanding the exerted pressure, allowing the proper compliance required for the biomechanical stimulation needed for regeneration. Although the international standards outline the specific requirements to evaluate vascular grafts, the challenge remains in choosing the proper biomaterial and manufacturing TEVGs with good quality features to perform satisfactorily. In this review, we aim to recognize the best strategies to reach suitable mechanical properties in cell-free TEVGs according to the reported success of different approaches in clinical trials and pre-clinical trials.
Collapse
|
14
|
Shan Y, Chen G, Shi Q, Huang J, Mi Y, Zhang W, Zhang H, Jia B. Heparin/Collagen-REDV Modification of Expanded Polytetrafluoroethylene Improves Regional Anti-thrombosis and Reduces Foreign Body Reactions in Local Tissues. Front Bioeng Biotechnol 2022; 10:916931. [PMID: 35992343 PMCID: PMC9386153 DOI: 10.3389/fbioe.2022.916931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Accepted: 06/07/2022] [Indexed: 11/29/2022] Open
Abstract
Prosthetic implants of expanded polytetrafluoroethylene (ePTFE) in the cardiovascular system have a high failure rate over the long term because of thrombosis and intimal hyperplasia. Although multiple surface modification methods have been applied to improve the anti-thrombotic and in situ endothelialization abilities of ePTFE, none have delivered outstanding results in vivo. Our previous study combined heparin/collagen multilayers and REDV peptides to modify ePTFE, and the in-vitro results showed that modification ePTFE with heparin/collagen-REDV can promote the cytocompatibility and antiplatelet property. This study illustrated the physical change, selective endothelial cells capture ability, and in vivo performance in further. The physical test demonstrated that this modification improved the hydrophilicity, flexibility and strength of ePTFE. A competition experiment of co-cultured endothelial cells and vascular smooth muscle cells verified that the heparin/collagen-REDV modification had high specificity for endothelial cell capture. A rabbit animal model was constructed to evaluate the in vivo performance of modified ePTFE implanted in the right ventricular outflow tract. The results showed that heparin/collagen-REDV modification was safe, promoted endothelialization, and successfully achieved regional anti-thrombosis without influencing body-wide coagulation function. The pathologic manifestations and mRNA expression pattern in tissues in contact with modified ePTFE indicated that this modification method may reduce M2-type macrophage infiltration and the expression of genes related to immune and inflammatory responses. The heparin/collagen-REDV modification may lower the incidence of complications related to ePTFE implantation and has good prospects for clinical use.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Bing Jia
- *Correspondence: Huifeng Zhang, ; Bing Jia,
| |
Collapse
|
15
|
Ma W, Wang L, Zhang Q, Dong X, Zhu T, Lu S. Electrospun PCL/collagen hybrid nanofibrous tubular graft based on post-network bond processing for vascular substitute. BIOMATERIALS ADVANCES 2022; 139:213031. [PMID: 35882122 DOI: 10.1016/j.bioadv.2022.213031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 07/10/2022] [Accepted: 07/11/2022] [Indexed: 06/15/2023]
Abstract
Inhibiting thrombus formation and intimal hyperplasia is essential for orthotopic tissue-engineered vascular grafts. The matching mechanical properties of autologous blood vessels and inhibition of platelet aggregation are considered as two points to improve the success rate of transplantation. The poly(ε-caprolactone)/collagen/heparin composite vascular graft (PCLHC) with three-dimensional network structure were constructed by electrospinning, which can mimic natural vascular biomechanics and enhance the viability of cells viability in vitro. The hybrid collagen matrix network nanofibers formed by electrospinning exhibited uniform and smooth morphology. The results of mechanical experiments showed that PCLHC had similar mechanical properties to natural blood vessels. And the addition of heparin enhanced the anticoagulation of PCLHC. Simultaneous three-component hybrid nanofibers showed a potentially reliable ability to promote the proliferation of human umbilical vein endothelial cells (HUVECs). In summary, all the results showed that the three-dimensional network structure of PCLHC presented the potential to heal injured vessels.
Collapse
Affiliation(s)
- Wenxin Ma
- School of Textiles and Fashion, Shanghai University of Engineering Science, 333 Longteng Rd., Shanghai 201620, PR China
| | - Liming Wang
- School of Textiles and Fashion, Shanghai University of Engineering Science, 333 Longteng Rd., Shanghai 201620, PR China.
| | - Qilu Zhang
- School of Textiles and Fashion, Shanghai University of Engineering Science, 333 Longteng Rd., Shanghai 201620, PR China
| | - Xiaoyuan Dong
- School of Textiles and Fashion, Shanghai University of Engineering Science, 333 Longteng Rd., Shanghai 201620, PR China
| | - Tonghe Zhu
- School of Chemistry and Chemical Engineering, Shanghai Engineering Research Center of Pharmaceutical Intelligent Equipment, Shanghai Frontiers Science Research Center for Druggability of Cardiovascular Non-coding RNA, Institute for Frontier Medical Technology, Shanghai University of Engineering Science, 333 Longteng Rd., Shanghai 201620, PR China
| | - Shuyang Lu
- Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, The Shanghai Institute of Cardiovascular Diseases, 180 Fenglin Rd., Shanghai 200032, PR China
| |
Collapse
|
16
|
A realistic arteriovenous dialysis graft model for hemodynamic simulations. PLoS One 2022; 17:e0269825. [PMID: 35862379 PMCID: PMC9302782 DOI: 10.1371/journal.pone.0269825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 05/30/2022] [Indexed: 11/19/2022] Open
Abstract
Objective The hemodynamic benefit of novel arteriovenous graft (AVG) designs is typically assessed using computational models that assume highly idealized graft configurations and/or simplified boundary conditions representing the peripheral vasculature. The objective of this study is to evaluate whether idealized AVG models are suitable for hemodynamic evaluation of new graft designs, or whether more realistic models are required. Methods An idealized and a realistic, clinical imaging based, parametrized AVG geometry were created. Furthermore, two physiological boundary condition models were developed to represent the peripheral vasculature. We assessed how graft geometry (idealized or realistic) and applied boundary condition models of the peripheral vasculature (physiological or distal zero-flow) impacted hemodynamic metrics related to AVG dysfunction. Results Anastomotic regions exposed to high WSS (>7, ≤40 Pa), very high WSS (>40 Pa) and highly oscillatory WSS were larger in the simulations using the realistic AVG geometry. The magnitude of velocity perturbations in the venous segment was up to 1.7 times larger in the realistic AVG geometry compared to the idealized one. When applying a (non-physiological zero-flow) boundary condition that neglected blood flow to and from the peripheral vasculature, we observed large regions exposed to highly oscillatory WSS. These regions could not be observed when using either of the newly developed distal boundary condition models. Conclusion Hemodynamic metrics related to AVG dysfunction are highly dependent on the geometry and the distal boundary condition model used. Consequently, the hemodynamic benefit of a novel graft design can be misrepresented when using idealized AVG modelling setups.
Collapse
|
17
|
Zizhou R, Wang X, Houshyar S. Review of Polymeric Biomimetic Small-Diameter Vascular Grafts to Tackle Intimal Hyperplasia. ACS OMEGA 2022; 7:22125-22148. [PMID: 35811906 PMCID: PMC9260943 DOI: 10.1021/acsomega.2c01740] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 06/03/2022] [Indexed: 06/15/2023]
Abstract
Small-diameter artificial vascular grafts (SDAVG) are used to bypass blood flow in arterial occlusive diseases such as coronary heart or peripheral arterial disease. However, SDAVGs are plagued by restenosis after a short while due to thrombosis and the thickening of the neointimal wall known as intimal hyperplasia (IH). The specific causes of IH have not yet been deduced; however, thrombosis formation due to bioincompatibility as well as a mismatch between the biomechanical properties of the SDAVG and the native artery has been attributed to its initiation. The main challenges that have been faced in fabricating SDAVGs are facilitating rapid re-endothelialization of the luminal surface of the SDAVG and replicating the complex viscoelastic behavior of the arteries. Recent strategies to combat IH formation have been mostly based on imitating the natural structure and function of the native artery (biomimicry). Thus, most recently, developed grafts contain a multilayered structure with a designated function for each layer. This paper reviews the current polymeric, biomimetic SDAVGs in preventing the formation of IH. The materials used in fabrication, challenges, and strategies employed to tackle IH are summarized and discussed, and we focus on the multilayered structure of current SDAVGs. Additionally, the future aspects in this area are pointed out for researchers to consider in their endeavor.
Collapse
Affiliation(s)
- Rumbidzai Zizhou
- Center
for Materials Innovation and Future Fashion (CMIFF), School of Fashion
and Textiles, RMIT University, Brunswick 3056, Australia
| | - Xin Wang
- Center
for Materials Innovation and Future Fashion (CMIFF), School of Fashion
and Textiles, RMIT University, Brunswick 3056, Australia
| | - Shadi Houshyar
- School
of Engineering, RMIT University, Melbourne 3000, Australia
| |
Collapse
|
18
|
Sadeghi R, Tomka B, Khodaei S, Daeian M, Gandhi K, Garcia J, Keshavarz-Motamed Z. Impact of extra-anatomical bypass on coarctation fluid dynamics using patient-specific lumped parameter and Lattice Boltzmann modeling. Sci Rep 2022; 12:9718. [PMID: 35690596 PMCID: PMC9188592 DOI: 10.1038/s41598-022-12894-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Accepted: 04/11/2022] [Indexed: 01/28/2023] Open
Abstract
Accurate hemodynamic analysis is not only crucial for successful diagnosis of coarctation of the aorta (COA), but intervention decisions also rely on the hemodynamics assessment in both pre and post intervention states to minimize patient risks. Despite ongoing advances in surgical techniques for COA treatments, the impacts of extra-anatomic bypass grafting, a surgical technique to treat COA, on the aorta are not always benign. Our objective was to investigate the impact of bypass grafting on aortic hemodynamics. We investigated the impact of bypass grafting on aortic hemodynamics using a patient-specific computational-mechanics framework in three patients with COA who underwent bypass grafting. Our results describe that bypass grafting improved some hemodynamic metrics while worsened the others: (1) Doppler pressure gradient improved (decreased) in all patients; (2) Bypass graft did not reduce the flow rate substantially through the COA; (3) Systemic arterial compliance increased in patients #1 and 3 and didn't change (improve) in patient 3; (4) Hypertension got worse in all patients; (5) The flow velocity magnitude improved (reduced) in patient 2 and 3 but did not improve significantly in patient 1; (6) There were elevated velocity magnitude, persistence of vortical flow structure, elevated turbulence characteristics, and elevated wall shear stress at the bypass graft junctions in all patients. We concluded that bypass graft may lead to pseudoaneurysm formation and potential aortic rupture as well as intimal hyperplasia due to the persistent abnormal and irregular aortic hemodynamics in some patients. Moreover, post-intervention, exposures of endothelial cells to high shear stress may lead to arterial remodeling, aneurysm, and rupture.
Collapse
Affiliation(s)
- Reza Sadeghi
- grid.25073.330000 0004 1936 8227Department of Mechanical Engineering, McMaster University, Hamilton, Canada ON
| | - Benjamin Tomka
- grid.25073.330000 0004 1936 8227Department of Mechanical Engineering, McMaster University, Hamilton, Canada ON
| | - Seyedvahid Khodaei
- grid.25073.330000 0004 1936 8227Department of Mechanical Engineering, McMaster University, Hamilton, Canada ON
| | - MohammadAli Daeian
- grid.25073.330000 0004 1936 8227Department of Mechanical Engineering, McMaster University, Hamilton, Canada ON
| | - Krishna Gandhi
- grid.25073.330000 0004 1936 8227Department of Mechanical Engineering, McMaster University, Hamilton, Canada ON
| | - Julio Garcia
- grid.489011.50000 0004 0407 3514Stephenson Cardiac Imaging Centre, Libin Cardiovascular Institute of Alberta, Calgary, AB Canada ,grid.22072.350000 0004 1936 7697Department of Radiology, University of Calgary, Calgary, AB Canada ,grid.22072.350000 0004 1936 7697Department of Cardiac Sciences, University of Calgary, Calgary, AB Canada ,grid.413571.50000 0001 0684 7358Alberta Children’s Hospital Research Institute, Calgary, AB Canada
| | - Zahra Keshavarz-Motamed
- grid.25073.330000 0004 1936 8227Department of Mechanical Engineering, McMaster University, Hamilton, Canada ON ,grid.25073.330000 0004 1936 8227School of Biomedical Engineering, McMaster University, Hamilton, ON Canada ,grid.25073.330000 0004 1936 8227School of Computational Science and Engineering, McMaster University, Hamilton, ON Canada
| |
Collapse
|
19
|
Wei Y, Wang F, Guo Z, Zhao Q. Tissue-engineered vascular grafts and regeneration mechanisms. J Mol Cell Cardiol 2021; 165:40-53. [PMID: 34971664 DOI: 10.1016/j.yjmcc.2021.12.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 12/19/2021] [Accepted: 12/22/2021] [Indexed: 02/07/2023]
Abstract
Cardiovascular diseases (CVDs) are life-threatening diseases with high morbidity and mortality worldwide. Vascular bypass surgery is still the ultimate strategy for CVD treatment. Autografts are the gold standard for graft transplantation, but insufficient sources limit their widespread application. Therefore, alternative tissue engineered vascular grafts (TEVGs) are urgently needed. In this review, we summarize the major strategies for the preparation of vascular grafts, as well as the factors affecting their patency and tissue regeneration. Finally, the underlying mechanisms of vascular regeneration that are mediated by host cells are discussed.
Collapse
Affiliation(s)
- Yongzhen Wei
- Zhengzhou Cardiovascular Hospital and 7th People's Hospital of Zhengzhou, Zhengzhou, Henan Province, China; State key Laboratory of Medicinal Chemical Biology & Key Laboratory of Bioactive Materials (Ministry of Education), College of Life Sciences, Nankai University, Tianjin, China
| | - Fei Wang
- State key Laboratory of Medicinal Chemical Biology & Key Laboratory of Bioactive Materials (Ministry of Education), College of Life Sciences, Nankai University, Tianjin, China
| | - Zhikun Guo
- Zhengzhou Cardiovascular Hospital and 7th People's Hospital of Zhengzhou, Zhengzhou, Henan Province, China
| | - Qiang Zhao
- Zhengzhou Cardiovascular Hospital and 7th People's Hospital of Zhengzhou, Zhengzhou, Henan Province, China; State key Laboratory of Medicinal Chemical Biology & Key Laboratory of Bioactive Materials (Ministry of Education), College of Life Sciences, Nankai University, Tianjin, China.
| |
Collapse
|
20
|
Arabiyat AS, Chen H, Erndt-Marino J, Burkhard K, Scola L, Fleck A, Wan LQ, Hahn MS. Hyperosmolar Ionic Solutions Modulate Inflammatory Phenotype and sGAG Loss in a Cartilage Explant Model. Cartilage 2021; 13:713S-721S. [PMID: 32975437 PMCID: PMC8804856 DOI: 10.1177/1947603520961167] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVE The objective of this study was to compare the effects of hyperosmolar sodium (Na+), lithium (Li+) and potassium (K+) on catabolic and inflammatory osteoarthritis (OA) markers and sulfated glycosaminoglycan (sGAG) loss in TNF-α-stimulated cartilage explants. METHODS Explants from bovine stifle joints were stimulated with TNF-α for 1 day to induce cartilage degradation followed by supplementation with 50 mM potassium chloride (KCl), 50 mM lithium chloride (LiCl), 50 mM sodium chloride (NaCl), or 100 nM dexamethasone for an additional 6 days. We assessed the effect of TNF-α stimulation and hyperosmolar ionic treatment on sGAG loss and expression of OA-associated proteins: ADAMTS-5, COX-2, MMP-1, MMP-13, and VEGF. RESULTS TNF-α treatment increased sGAG loss (P < 0.001) and expression of COX-2 (P = 0.018), MMP-13 (P < 0.001), and VEGF (P = 0.017) relative to unstimulated controls. Relative to activated controls, LiCl and dexamethasone treatment attenuated sGAG loss (P = 0.008 and P = 0.042, respectively) and expression of MMP-13 (P = 0.005 and P = 0.036, respectively). In contrast, KCl treatment exacerbated sGAG loss (P = 0.032) and MMP-1 protein expression (P = 0.010). NaCl treatment, however, did not alter sGAG loss or expression of OA-related proteins. Comparing LiCl and KCl treatment shows a potent reduction (P < 0.05) in catabolic and inflammatory mediators following LiCl treatment. CONCLUSION These results suggest that these ionic species elicit varying responses in TNF-α-stimulated explants. Cumulatively, these findings support additional studies of hyperosmolar ionic solutions for potential development of novel intraarticular injections targeting OA.
Collapse
Affiliation(s)
- Ahmad S. Arabiyat
- Department of Biomedical Engineering,
Rensselaer Polytechnic Institute (RPI), Troy, NY, USA
- Center for Biotechnology and
Interdisciplinary Studies, Rensselaer Polytechnic Institute (RPI), Troy, NY,
USA
| | - Hongyu Chen
- Department of Biomedical Engineering,
Rensselaer Polytechnic Institute (RPI), Troy, NY, USA
- Center for Biotechnology and
Interdisciplinary Studies, Rensselaer Polytechnic Institute (RPI), Troy, NY,
USA
| | - Josh Erndt-Marino
- Department of Biomedical Engineering,
Tufts University, Medford, MA, USA
| | - Katie Burkhard
- Department of Biomedical Engineering,
Rensselaer Polytechnic Institute (RPI), Troy, NY, USA
| | - Lisa Scola
- Department of Biomedical Engineering,
Rensselaer Polytechnic Institute (RPI), Troy, NY, USA
| | - Allison Fleck
- Department of Biomedical Engineering,
Rensselaer Polytechnic Institute (RPI), Troy, NY, USA
- Center for Biotechnology and
Interdisciplinary Studies, Rensselaer Polytechnic Institute (RPI), Troy, NY,
USA
| | - Leo Q. Wan
- Department of Biomedical Engineering,
Rensselaer Polytechnic Institute (RPI), Troy, NY, USA
- Center for Biotechnology and
Interdisciplinary Studies, Rensselaer Polytechnic Institute (RPI), Troy, NY,
USA
| | - Mariah S. Hahn
- Department of Biomedical Engineering,
Rensselaer Polytechnic Institute (RPI), Troy, NY, USA
- Center for Biotechnology and
Interdisciplinary Studies, Rensselaer Polytechnic Institute (RPI), Troy, NY,
USA
| |
Collapse
|
21
|
Dye-Mediated Photo-Oxidation Biomaterial Fixation: Analysis of Bioinductivity and Mechanical Properties of Bovine Pericardium for Use in Cardiac Surgery. Int J Mol Sci 2021; 22:ijms221910768. [PMID: 34639108 PMCID: PMC8509588 DOI: 10.3390/ijms221910768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Revised: 09/27/2021] [Accepted: 09/30/2021] [Indexed: 11/17/2022] Open
Abstract
Extracellular matrix bioscaffolds can influence the cardiac microenvironment and modulate endogenous cellular mechanisms. These materials can optimize cardiac surgery for repair and reconstruction. We investigated the biocompatibility and bioinductivity of bovine pericardium fixed via dye-mediated photo-oxidation on human cardiac fibroblast activity. We compared a dye-mediated photo-oxidation fixed bioscaffold to glutaraldehyde-fixed and non-fixed bioscaffolds reported in contemporary literature in cardiac surgery. Human cardiac fibroblasts from consenting patients were seeded on to bioscaffold materials to assess the biocompatibility and bioinductivity. Human cardiac fibroblast gene expression, secretome, morphology and viability were studied. Dye-mediated photo-oxidation fixed acellular bovine pericardium preserves human cardiac fibroblast phenotype and viability; and potentiates a pro-vasculogenic paracrine response. Material tensile properties were compared with biomechanical testing. Dye-mediated photo-oxidation fixed acellular bovine pericardium had higher compliance compared to glutaraldehyde-fixed bioscaffold in response to tensile force. The biocompatibility, bioinductivity, and biomechanical properties of dye-mediated photo-oxidation fixed bovine pericardium demonstrate its feasibility as a bioscaffold for use in cardiac surgery. As a fixed yet bioinductive solution, this bioscaffold demonstrates enhanced compliance and retains bioinductive properties that may leverage endogenous reparative pathways. Dye-mediated photo-oxidation fixed bioscaffold warrants further investigation as a viable tool for cardiac repair and reconstruction.
Collapse
|
22
|
Yoon WJ, Rodriguez VM, Lee CJ. Insights on Bridging Stent Grafts in Fenestrated and Branched Aortic Endografting. Vasc Specialist Int 2021; 37:14. [PMID: 34135130 PMCID: PMC8209487 DOI: 10.5758/vsi.210025] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/27/2021] [Accepted: 05/28/2021] [Indexed: 11/20/2022] Open
Abstract
Major branches of the aortic arch and visceral aorta pose a particular challenge for endovascular repair of aneurysms involving these regions. To preserve perfusion through these essential branches, fenestrated and branched endografts have been used. Current fenestrated and branched aortic endografts have evolved into modular devices in which the aortic main body provides appropriate access to the target branch vessel either through reinforced fenestrations or directional cuffs as the hinge point for bridging stent grafts (BSGs). BSGs are used to connect the aortic main body and target branch vessel, and must provide both unhindered flow and a seal. Appropriate selection of BSG for target vessels in branched and fenestrated endovascular aortic repair is critical for technical success and durability. At present, there are no dedicated devices for use as BSGs, and a variety of stent grafts are currently used off-label. In this report, we review the available published series on the performance of presently available BSGs in relation to their design and selection.
Collapse
Affiliation(s)
- William J Yoon
- Division of Vascular Surgery, Department of Surgery, University of California-Davis, Sacramento, CA, USA.,Section of Vascular Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Victor M Rodriguez
- Division of Vascular Surgery, Department of Surgery, University of California-Davis, Sacramento, CA, USA.,Division of Cardiothoracic Surgery, Department of Surgery, University of California-Davis, Sacramento, CA, USA
| | - Cheong Jun Lee
- Division of Vascular Surgery, Department of Surgery, NorthShore University HealthSystem, University of Chicago Pritzker School of Medicine, Evanston, IL, USA
| |
Collapse
|
23
|
Bai S, Zhang X, Zang L, Yang S, Chen X, Yuan X. Electrospinning of Biomaterials for Vascular Regeneration. Chem Res Chin Univ 2021. [DOI: 10.1007/s40242-021-1125-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
24
|
Maleckis K, Kamenskiy A, Lichter EZ, Oberley-Deegan R, Dzenis Y, MacTaggart J. Mechanically tuned vascular graft demonstrates rapid endothelialization and integration into the porcine iliac artery wall. Acta Biomater 2021; 125:126-137. [PMID: 33549808 DOI: 10.1016/j.actbio.2021.01.047] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 01/26/2021] [Accepted: 01/28/2021] [Indexed: 12/12/2022]
Abstract
Mechanical properties of vascular grafts likely play important roles in healing and tissue regeneration. Healthy arteries are compliant at low pressures but stiffen rapidly with increasing load, ensuring sufficient volumetric expansion without overstretching the vessel. Commercial synthetic vascular grafts are stiff and unable to expand under physiologic loads, which may result in altered hemodynamics, deleterious cellular responses, and compromised clinical performance. The goal of this study was to develop an Elastomeric Nanofibrillar Graft (ENG) with artery-tuned nonlinear compliance and compare its healing responses to conventional expanded polytetrafluoroethylene (ePTFE) grafts in a porcine iliac artery model. Human and porcine iliac arteries were mechanically characterized, and an ENG with similar properties was created by utilizing residual strains within electrospun nanofibers. The ENG was tested for implantation suitability and implanted onto n = 5 domestic swine iliac arteries, with control ePTFE grafts implanted onto the contralateral iliac arteries. After two weeks in vivo, all iliac arteries and grafts remained patent with no signs of thrombosis or dilation. The mechanically tuned ENG implants exhibited a more confluent CD31-positive cell monolayer (1.53 ± 0.73 µm2/mm vs 0.52 ± 0.55 µm2/mm, p = 0.042) on the graft lumenal surface and a higher fraction of αSMA-positive cells (16.2 ± 8.6% vs 1.4 ± 0.7%, p = 0.018) within the graft wall than the ePTFE controls. Despite heavy cellular infiltration, the ENG retained its artery-like mechanical characteristics after two weeks in vivo. These short-term results demonstrate potential advantages of mechanically tuned biomimetic vascular grafts over standard ePTFE grafts. STATEMENT OF SIGNIFICANCE: Off-the-shelf synthetic vascular grafts are often the only option available for treating advanced stages of vascular disease. Despite significant efforts devoted to improving their biochemical characteristics, synthetic peripheral arterial grafts continue to demonstrate poor clinical outcomes leading to costly reinterventions. Here, we hypothesized that a synthetic vascular graft with elastomeric mechanical properties tuned to a healthy peripheral artery promotes better healing responses than a synthetic stiff graft. To test this hypothesis, we developed an Elastomeric Nanofibrillar Graft (ENG) with artery-tuned mechanical properties and compared its performance to a commercial ePTFE graft in a preclinical porcine iliac artery model. Our results suggest that mechanically tuned ENGs can offer better healing responses, potentially leading to better clinical outcomes for peripheral arterial repairs.
Collapse
|
25
|
Hejazi M, Sassani F, Gagnon J, Hsiang Y, Phani AS. Deformation mechanics of self-expanding venous stents: Modelling and experiments. J Biomech 2021; 120:110333. [PMID: 33730560 DOI: 10.1016/j.jbiomech.2021.110333] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 02/12/2021] [Indexed: 10/22/2022]
Abstract
Deformation properties of venous stents based on braided design, chevron design, Z design, and diamond design are compared using in vitro experiments coupled with analytical and finite element modelling. Their suitability for deployment in different clinical contexts is assessed based on their deformation characteristics. Self-expanding stainless steel stents possess superior collapse resistance compared to Nitinol stents. Consequently, they may be more reliable to treat diseases like May-Thurner syndrome in which resistance against a concentrated (pinching) force applied on the stent is needed to prevent collapse. Braided design applies a larger radial pressure particularly for vessels of diameter smaller than 75% of its nominal diameter, making it suitable for a long lesion with high recoil. Z design has the least foreshortening, which aids in accurate deployment. Nitinol stents are more compliant than their stainless steel counterparts, which indicates their suitability in veins. The semi-analytical method presented can aid in rapid assessment of topology governed deformation characteristics of stents and their design optimization.
Collapse
Affiliation(s)
- Masoud Hejazi
- Department of Mechanical Engineering, 6250 Applied Science Lane, University of British Columbia, Vancouver, B.C V6T 1Z4, Canada
| | - Farrokh Sassani
- Department of Mechanical Engineering, 6250 Applied Science Lane, University of British Columbia, Vancouver, B.C V6T 1Z4, Canada
| | - Jöel Gagnon
- Division of Vascular Surgery, 4219-2775 Laurel Street, Vancouver General Hospital, Vancouver, B.C V5Z 1M9, Canada
| | - York Hsiang
- Division of Vascular Surgery, 4219-2775 Laurel Street, Vancouver General Hospital, Vancouver, B.C V5Z 1M9, Canada
| | - A Srikantha Phani
- Department of Mechanical Engineering, 6250 Applied Science Lane, University of British Columbia, Vancouver, B.C V6T 1Z4, Canada.
| |
Collapse
|
26
|
Caracciolo PC, Diaz-Rodriguez P, Ardao I, Moreira D, Montini-Ballarin F, Abraham GA, Concheiro A, Alvarez-Lorenzo C. Evaluation of human umbilical vein endothelial cells growth onto heparin-modified electrospun vascular grafts. Int J Biol Macromol 2021; 179:567-575. [PMID: 33675835 DOI: 10.1016/j.ijbiomac.2021.03.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 02/26/2021] [Accepted: 03/02/2021] [Indexed: 12/30/2022]
Abstract
One of the main challenges of cardiovascular tissue engineering is the development of bioresorbable and compliant small-diameter vascular grafts (SDVG) for patients where autologous grafts are not an option. In this work, electrospun bilayered bioresorbable SDVG based on blends of poly(L-lactic acid) (PLLA) and segmented polyurethane (PHD) were prepared and evaluated. The inner layer of these SDVG was surface-modified with heparin, following a methodology involving PHD urethane functional groups. Heparin was selected as anticoagulant agent, and also due to its ability to promote human umbilical vein endothelial cells (HUVECs) growth and to inhibit smooth muscle cells over-proliferation, main cause of neointimal hyperplasia and restenosis. Immobilized heparin was quantified and changes in SDVG microstructure were investigated through SEM. Tensile properties of the heparin-functionalized SDVG resembled those of saphenous vein. Vascular grafts were seeded with HUVECs and cultured on a flow-perfusion bioreactor to analyze the effect of heparin on graft endothelization under simulated physiological-like conditions. The analysis of endothelial cells attachment and gene expression (Real-Time PCR) pointed out that the surface functionalization with heparin successfully promoted a stable and functional endothelial cell layer.
Collapse
Affiliation(s)
- Pablo C Caracciolo
- Instituto de Investigaciones en Ciencia y Tecnología de Materiales, INTEMA (UNMdP-CONICET), Av. Cristóbal Colón 10850, B7606WV Mar del Plata, Argentina.
| | - Patricia Diaz-Rodriguez
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma (GI-1645), Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - Inés Ardao
- BioFarma Research group, Center for Research in Molecular Medicine and Chronic Diseases (CiMUS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - David Moreira
- BioFarma Research group, Center for Research in Molecular Medicine and Chronic Diseases (CiMUS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - Florencia Montini-Ballarin
- Instituto de Investigaciones en Ciencia y Tecnología de Materiales, INTEMA (UNMdP-CONICET), Av. Cristóbal Colón 10850, B7606WV Mar del Plata, Argentina
| | - Gustavo A Abraham
- Instituto de Investigaciones en Ciencia y Tecnología de Materiales, INTEMA (UNMdP-CONICET), Av. Cristóbal Colón 10850, B7606WV Mar del Plata, Argentina
| | - Angel Concheiro
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma (GI-1645), Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - Carmen Alvarez-Lorenzo
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, I+D Farma (GI-1645), Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| |
Collapse
|
27
|
Wang Z, Liu L, Mithieux SM, Weiss AS. Fabricating Organized Elastin in Vascular Grafts. Trends Biotechnol 2020; 39:505-518. [PMID: 33019966 DOI: 10.1016/j.tibtech.2020.09.003] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 09/07/2020] [Accepted: 09/08/2020] [Indexed: 01/01/2023]
Abstract
Surgically bypassing or replacing a severely damaged artery using a biodegradable synthetic vascular graft is a promising treatment that allows for the remodeling and regeneration of the graft to form a neoartery. Elastin-based structures, such as elastic fibers, elastic lamellae, and laminae, are key functional components in the arterial extracellular matrix. In this review, we identify the lack of elastin in vascular grafts as a key factor that prevents their long-term success. We further summarize advances in vascular tissue engineering that are focused on either de novo production of organized elastin or incorporation of elastin-based biomaterials within vascular grafts to mitigate failure and enhance enduring in vivo performance.
Collapse
Affiliation(s)
- Ziyu Wang
- Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia; School of Life and Environmental Sciences, University of Sydney, Sydney, NSW 2006, Australia
| | - Linyang Liu
- Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia; School of Life and Environmental Sciences, University of Sydney, Sydney, NSW 2006, Australia
| | - Suzanne M Mithieux
- Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia; School of Life and Environmental Sciences, University of Sydney, Sydney, NSW 2006, Australia
| | - Anthony S Weiss
- Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia; School of Life and Environmental Sciences, University of Sydney, Sydney, NSW 2006, Australia; Sydney Nano Institute, University of Sydney, Sydney, NSW 2006, Australia.
| |
Collapse
|
28
|
Riboldi SA, Tozzi M, Bagardi M, Ravasio G, Cigalino G, Crippa L, Piccolo S, Nahal A, Spandri M, Catto V, Tironi M, Greco FG, Remuzzi A, Acocella F. A Novel Hybrid Silk Fibroin/Polyurethane Arteriovenous Graft for Hemodialysis: Proof-of-Concept Animal Study in an Ovine Model. Adv Healthc Mater 2020; 9:e2000794. [PMID: 32914588 DOI: 10.1002/adhm.202000794] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 07/17/2020] [Indexed: 12/25/2022]
Abstract
To solve the problem of vascular access failure, a novel semi-degradable hybrid vascular graft, manufactured by electrospinning using silk fibroin and polyurethane (Silkothane), has been previously developed and characterized in vitro. This proof-of-concept animal study aims at evaluating the performances of Silkothane grafts in a sheep model of arteriovenous shunt, in terms of patency and short-term remodeling. Nine Silkothane grafts are implanted between the common carotid artery and the external jugular vein of nine sheep, examined by palpation three times per week, by echo-color Doppler every two weeks, and euthanized at 30, 60, and 90 days (N = 3 per group). At sacrifice, grafts are harvested and submitted for histopathology and/or scanning electron microcopy (SEM). No cases of graft-related complications are recorded. Eight of nine sheep (89%) show 100% primary unassisted patency at the respective time of sacrifice (flow rate 1.76 ± 0.61 L min-1 , one case of surgery-related thrombosis excluded). Histopathology and SEM analysis evidence signs of inflammation and pseudointima inside the graft lumen, especially at the venous anastomosis; however, endoluminal stenosis never impairs the functionality of the shunt and coverage by endothelial cells is observed. In this model, Silkothane grafts grant safety and 100% patency up to 90 days.
Collapse
Affiliation(s)
| | - Matteo Tozzi
- Department of Medicine and Surgery Università degli Studi dell'Insubria Varese 21100 Italy
| | - Mara Bagardi
- Department of Veterinary Medicine Università degli Studi di Milano Milano 20122 Italy
| | - Giuliano Ravasio
- Department of Veterinary Medicine Università degli Studi di Milano Milano 20122 Italy
| | - Giorgio Cigalino
- Centre for Clinical Veterinary Medicine and Experimental Zootechnics Università degli Studi di Milano Milano 20122 Italy
| | - Luca Crippa
- Department of Medicine and Surgery Università degli Studi di Milano Bicocca Milano 20126 Italy
| | - Solange Piccolo
- Department of Medicine and Surgery Università degli Studi dell'Insubria Varese 21100 Italy
| | - Amal Nahal
- Department of Medicine and Surgery Università degli Studi dell'Insubria Varese 21100 Italy
| | | | | | - Matteo Tironi
- Department of Bioengineering IRCCS Istituto di Ricerche Farmacologiche Mario Negri Bergamo 24126 Italy
| | | | - Andrea Remuzzi
- Department of Management, Information and Production Engineering Università degli Studi di Bergamo Bergamo 24129 Italy
| | - Fabio Acocella
- Department of Health, Animal Science and Food Safety Università degli Studi di Milano Milano 20122 Italy
| |
Collapse
|
29
|
Antonyshyn JA, D'''''Costa KA, Santerre JP. Advancing tissue-engineered vascular grafts via their endothelialization and mechanical conditioning. THE JOURNAL OF CARDIOVASCULAR SURGERY 2020; 61:555-576. [PMID: 32909708 DOI: 10.23736/s0021-9509.20.11582-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Tissue engineering has garnered significant attention for its potential to address the predominant modes of failure of small diameter vascular prostheses, namely mid-graft thrombosis and anastomotic intimal hyperplasia. In this review, we described two main features underpinning the promise of tissue-engineered vascular grafts: the incorporation of an antithrombogenic endothelium, and the generation of a structurally and biomechanically mimetic extracellular matrix. From the early attempts at the in-vitro endothelialization of vascular prostheses in the 1970s through to the ongoing clinical trials of fully tissue-engineered vascular grafts, the historical advancements and unresolved challenges that characterize the current state-of-the-art are summarized in a manner that establishes a guide for the development of an effective vascular prosthesis for small diameter arterial reconstruction. The importance of endothelial cell purity and their arterial specification for the prevention of both diffuse neointimal hyperplasia and the accelerated development of atherosclerotic lesions is delineated. Additionally, the need for an extracellular matrix that recapitulates both the composition and structure of native elastic arteries to facilitate the protracted stability and patency of an engineered vasoactive conduit is described. Finally, the capacity of alternative sources of cells and mechanical conditioning to overcome these technical barriers to the clinical translation of an effective small diameter vascular prosthesis is discussed. In conclusion, this review provides an overview of the historical development of tissue-engineered vascular grafts, highlighting specific areas warranting further research, and commentating on the outlook of a clinically feasible and therapeutically efficacious vascular prosthesis for small diameter arterial reconstruction.
Collapse
Affiliation(s)
- Jeremy A Antonyshyn
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada.,Translational Biology and Engineering Program, Ted Rogers Centre for Heart Research, Toronto, ON, Canada
| | - Katya A D'''''Costa
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada.,Translational Biology and Engineering Program, Ted Rogers Centre for Heart Research, Toronto, ON, Canada
| | - J Paul Santerre
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada - .,Translational Biology and Engineering Program, Ted Rogers Centre for Heart Research, Toronto, ON, Canada.,Faculty of Dentistry, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
30
|
Jeong Y, Yao Y, Yim EKF. Current understanding of intimal hyperplasia and effect of compliance in synthetic small diameter vascular grafts. Biomater Sci 2020; 8:4383-4395. [PMID: 32643723 PMCID: PMC7452756 DOI: 10.1039/d0bm00226g] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Despite much effort, synthetic small diameter vascular grafts still face limited success due to vascular wall thickening known as intimal hyperplasia (IH). Compliance mismatch between graft and native vessels has been proposed to be one of a key mechanical factors of synthetic vascular grafts that could contribute to the formation of IH. While many methods have been developed to determine compliance both in vivo and in vitro, the effects of compliance mismatch still remain uncertain. This review aims to explain the biomechanical factors that are responsible for the formation and development of IH and their relationship with compliance mismatch. Furthermore, this review will address the current methods used to measure compliance both in vitro and in vivo. Lastly, current limitations in understanding the connection between the compliance of vascular grafts and the role it plays in the development and progression of IH will be discussed.
Collapse
Affiliation(s)
- YeJin Jeong
- Department of Chemical engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada.
| | | | | |
Collapse
|
31
|
Akbari S, Mohebbi-Kalhori D, Samimi A. Effect of corrugated structure on the collapsing of the small-diameter vascular scaffolds. J Biomater Appl 2020; 34:1355-1367. [DOI: 10.1177/0885328220910021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Saeed Akbari
- Department of Chemical Engineering, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Islamic Republic of Iran
| | - Davod Mohebbi-Kalhori
- Department of Chemical Engineering, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Islamic Republic of Iran
| | - Abdolreza Samimi
- Department of Chemical Engineering, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Islamic Republic of Iran
| |
Collapse
|
32
|
Van de Walle AB, Moore MC, McFetridge PS. Sequential adaptation of perfusion and transport conditions significantly improves vascular construct recellularization and biomechanics. J Tissue Eng Regen Med 2020; 14:510-520. [PMID: 32012480 DOI: 10.1002/term.3015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 12/25/2019] [Accepted: 01/10/2020] [Indexed: 12/31/2022]
Abstract
Recellularization of ex vivo-derived scaffolds remains a significant hurdle primarily due to the scaffolds subcellular pore size that restricts initial cell seeding to the scaffolds periphery and inhibits migration over time. With the aim to improve cell migration, repopulation, and graft mechanics, the effects of a four-step culture approach were assessed. Using an ex vivo-derived vein as a model scaffold, human smooth muscle cells were first seeded onto its ablumen (Step 1: 3 hr) and an aggressive 0-100% nutrient gradient (lumenal flow under hypotensive pressure) was created to initiate cell migration across the scaffold (Step 2: Day 0 to 19). The effects of a prolonged aggressive nutrient gradient created by this single lumenal flow was then compared with a dual flow (lumenal and ablumenal) in Step 3 (Day 20 to 30). Analyses showed that a single lumenal flow maintained for 30 days resulted in a higher proportion of cells migrating across the scaffold toward the vessel lumen (nutrient source), with improved distribution. In Step 4 (Day 31 to 45), the transition from hypotensive pressure (12/8 mmHg) to normotensive (arterial-like) pressure (120/80 mmHg) was assessed. It demonstrated that recellularized scaffolds exposed to arterial pressures have increased glycosaminoglycan deposition, physiological modulus, and Young's modulus. By using this stepwise conditioning, the challenging recellularization of a vein-based scaffold and its positive remodeling toward arterial biomechanics were obtained.
Collapse
Affiliation(s)
- Aurore B Van de Walle
- Laboratoire Matière et Systèmes, Complexes MSC, UMR 7057, CNRS & University Paris Diderot, Paris, France.,J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL
| | - Marc C Moore
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL.,Stephenson School of Biomedical Engineering, Carson Engineering Center, University of Oklahoma, Norman, OK
| | - Peter S McFetridge
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL
| |
Collapse
|