1
|
Matarazzo F, Passaro ML, Rinaldi M, Afflitto GG, Aiello F, Avolio FC, Aurilia A, Strianese D, Nucci C, Costagliola C. Ahmed and baerveldt in glaucoma surgery: what is the safest choice? - a systematic review and meta-analysis. Graefes Arch Clin Exp Ophthalmol 2025:10.1007/s00417-025-06794-w. [PMID: 40164796 DOI: 10.1007/s00417-025-06794-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2024] [Revised: 01/28/2025] [Accepted: 03/06/2025] [Indexed: 04/02/2025] Open
Abstract
BACKGROUND/AIMS Glaucoma drainage devices (GDDs) are essential in managing complex glaucoma cases. This review focuses on the Ahmed glaucoma valve (AGV) and Baerveldt glaucoma implant (BGI), the most commonly used GDDs. We aim to evaluate complications associated with AGV and BGI, particularly post-operative hypotony. METHODS We systematically reviewed randomized controlled trials (RCTs) and non-randomized studies (NRSs) comparing AGV and BGI. The primary outcome was persistent hypotony (IOP < 5 mmHg). Secondary outcomes included hypotony maculopathy, choroidal effusion, suprachoroidal hemorrhage, vision loss, cystoid macular edema, diplopia, corneal decompensation, endophthalmitis, hyphema, further surgery for IOP control, tube interventions, exposure, and occlusion. RESULTS Thirteen studies (4 RCTs, 9 NRSs) with 2,513 eyes were analyzed. AGV was associated with a lower incidence of persistent hypotony in RCTs (0.6% vs. 4.4%, p = 0.006), choroidal effusion (4.95% vs. 15.8%, p < 0.0001), vision loss (9% vs. 18.9%, p = 0.01), and cystoid macular edema (2.5% vs. 9.6%, p = 0.009). BGI showed a lower need for further surgery to control IOP in RCTs (14.5% vs. 7.5%, p = 0.01). No significant differences were found for other outcomes, including suprachoroidal hemorrhage, corneal decompensation, and tube-related complications. CONCLUSION AGV seems to offers a safer profile with fewer hypotony-related complications compared to BGI. Personalized device selection is crucial for optimizing glaucoma surgery outcomes. Further high-quality, well-designed studies are needed to validate those results.
Collapse
Affiliation(s)
- Francesco Matarazzo
- Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples "Federico II", Naples, Italy
- Department of Physics "Ettore Pancini", University of Naples "Federico II", Naples, Italy
| | - Maria Laura Passaro
- Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples "Federico II", Naples, Italy.
- Department of Medicine and Health Sciences "V. Tiberio", University of Molise, Campobasso, Italy.
| | - Michele Rinaldi
- Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples "Federico II", Naples, Italy
| | - Gabriele Gallo Afflitto
- Department of Experimental Medicine, Ophthalmology Unit, University of Rome "Tor Vergata", Rome, IT, Italy
- Moorfields Eye Hospital NHS Foundation Trust, London, UK
| | - Francesco Aiello
- Department of Experimental Medicine, Ophthalmology Unit, University of Rome "Tor Vergata", Rome, IT, Italy
| | - Fabio Claudio Avolio
- Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples "Federico II", Naples, Italy
| | - Alessandro Aurilia
- Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples "Federico II", Naples, Italy
| | - Diego Strianese
- Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples "Federico II", Naples, Italy
| | - Carlo Nucci
- Department of Experimental Medicine, Ophthalmology Unit, University of Rome "Tor Vergata", Rome, IT, Italy
| | - Ciro Costagliola
- Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples "Federico II", Naples, Italy
| |
Collapse
|
2
|
Gutkind NE, Gedde SJ. Reporting outcomes of minimally invasive glaucoma surgery. Curr Opin Ophthalmol 2025; 36:140-145. [PMID: 39470463 DOI: 10.1097/icu.0000000000001100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/30/2024]
Abstract
PURPOSE OF REVIEW This review presents guidelines for designing studies and reporting efficacy and safety outcomes in minimally invasive glaucoma surgery (MIGS) research. RECENT FINDINGS Adherence to reporting guidelines in MIGS studies is crucial for providers and patients to appraise surgical options. Recent guidelines have outlined appropriate methodology, efficacy outcomes, and safety reporting, so that study results are presented in an interpretable and uniform manner. SUMMARY MIGS are changing the glaucoma treatment paradigm by offering safer, less invasive alternatives to traditional filtering surgery. However, inconsistent reporting of outcomes in MIGS trials hampers comparison and clinical decision-making. Recent guidelines have aimed to highlight appropriate methodology and encourage standardization in reporting outcomes to improve the quality of MIGS literature. Key considerations include defining baseline intraocular pressure, reporting standardized demographic data, using consistent endpoints, presenting standardized figures, evaluating medication use, and documenting adverse events. By adhering to these guidelines, MIGS trials can offer clearer insights into surgical outcomes, aiding both surgeons and patients in treatment decisions.
Collapse
Affiliation(s)
- Naomi E Gutkind
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
| | | |
Collapse
|
3
|
Ahmed IK, Vera V, Stalmans I, Fea AM, Mansouri K, Gu X, Craven ER, Reitsamer HA. Effectiveness and safety of the XEN45 gel stent compared to trabeculectomy in primary open-angle glaucoma: the Gold-Standard Pathway Study. BMJ Open Ophthalmol 2025; 10:e001696. [PMID: 39915236 PMCID: PMC11804186 DOI: 10.1136/bmjophth-2024-001696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Accepted: 11/30/2024] [Indexed: 02/09/2025] Open
Abstract
AIM To compare the gel stent to trabeculectomy in the Gold-Standard Pathway Study (GPS) patients with primary open-angle glaucoma (POAG). METHODS In the GPS, patients with elevated intraocular pressure (IOP) poorly controlled with IOP-lowering medication were randomised (2:1, gel stent:trabeculectomy). Aggregate primary endpoint: patients (%) at month 12 achieving ≥20% IOP reduction from baseline without medication increase, clinical hypotony, vision loss to counting fingers or secondary surgical intervention (SSI). Secondary endpoints included changes in mean IOP and medication count from baseline; postoperative interventions; visual recovery; postoperative complications; and the Symptom and Health Problem Checklist (SHPC-18) questionnaire. RESULTS Of 130 eyes with POAG treated/analysed (gel stent, n=88; trabeculectomy, n=42); 61.4% and 69.0% met the primary endpoint, respectively (p=0.394). At month 12, the change from baseline in mean IOP was statistically greater post-trabeculectomy (by 2.8 mm Hg; p=0.028) than post-gel stent. Postoperative intervention and postoperative complication rates were 39.8% and 75.0% (gel stent) versus 76.2% and 92.9% (trabeculectomy), respectively. Hypotony (IOP ≤6 mm Hg at two consecutive visits) rates were 14.8% (gel stent) and 28.6% (trabeculectomy). Visual recovery was faster/better (per the mean and time to first return to baseline best corrected visual acuity) and SHPC-18-related improvements were greater post-gel stent than post-trabeculectomy. CONCLUSION Similar proportions of eyes with POAG achieved the primary endpoint post-gel stent and post-trabeculectomy. The mean IOP reduction was statistically greater post-trabeculectomy. The gel stent resulted in fewer postoperative interventions, faster/better visual recovery, favourable patient-reported outcomes and fewer specific adverse events, although more SSIs and IOP elevations were observed.
Collapse
Affiliation(s)
- Iqbal K Ahmed
- John Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Vanessa Vera
- Allergan, an AbbVie Company, Irvine, California, USA
| | | | - Antonio Maria Fea
- Surgical Science, Clinica Oculistica dell'Universita di Torino, Torino, Italy
| | - Kaweh Mansouri
- Swiss Visio, Montchoisi Clinic, Glaucoma Research Centre, Lausanne, Switzerland
- Department of Ophthalmology, University of Colorado School of Medicine, Denver, Colorado, USA
| | - Xuemin Gu
- Allergan, an AbbVie Company, Irvine, California, USA
| | - Earl Randy Craven
- Medical Affairs, Allergan, an AbbVie company, Irvine, California, USA
| | - Herbert A Reitsamer
- Department of Ophthalmology and Optometry, University Clinic Salzburg, Paracelsus Medical University, Salzburg, Austria
| |
Collapse
|
4
|
Gedde SJ, Vinod K, Bowden EC, Kolomeyer NN, Chopra V, Challa P, Budenz DL, Repka MX, Lum F. Special Commentary: Reporting Clinical Endpoints in Studies of Minimally Invasive Glaucoma Surgery. Ophthalmology 2025; 132:141-153. [PMID: 39127407 DOI: 10.1016/j.ophtha.2024.07.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 07/22/2024] [Accepted: 07/29/2024] [Indexed: 08/12/2024] Open
Abstract
Minimally invasive glaucoma surgery (MIGS) refers to a group of procedures generally characterized by an ab interno approach, minimal trauma to ocular tissue, moderate efficacy, an excellent safety profile, and rapid recovery. The number of MIGS procedures continues to increase, and their use has become widespread among glaucoma and cataract specialists. Standardization of the methodology and reporting of clinical endpoints in MIGS investigations enhances interpretation and comparison across different studies. The assessment of surgical interventions not only should consider statistical significance, but also whether the outcome is meaningful to patients. Minimal clinically important difference (MCID) is defined as the smallest change in a treatment outcome that is considered beneficial for an individual patient and prompts a change in their clinical management. Expert consensus is an accepted approach to determine the MCID. The American Academy of Ophthalmology's Glaucoma Preferred Practice Pattern® Committee is an expert panel that develops guidelines identifying characteristics and components of quality eye care. The Committee recommends that the cumulative probability of surgical success at 2 years with Kaplan-Meier survival analysis be used as the primary efficacy endpoint in MIGS studies. The Committee suggests that surgical success for standalone MIGS be defined as intraocular pressure (IOP) of 21 mmHg or less and reduced by 20% or more from baseline without an increase in glaucoma medications, additional laser or incisional glaucoma surgery, loss of light perception vision, or hypotony. The proposed MCID for the cumulative probability of success of standalone MIGS at 2 years is 50%. The panel recommends that surgical success for MIGS combined with cataract extraction with intraocular lens implantation (CE-IOL) be defined as a decrease in glaucoma medical therapy of 1 medication or more from baseline without an increase in IOP or IOP of 21 mmHg or less and reduced by 20% or more from baseline without an increase in glaucoma medications, additional laser or incisional glaucoma surgery, loss of light perception vision, or hypotony. The suggested MCID for the cumulative probability of success for MIGS combined with CE-IOL at 2 years is 65%. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Steven J Gedde
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida
| | - Kateki Vinod
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai and New York Eye and Ear Infirmary of Mount Sinai, New York, New York
| | - Eileen C Bowden
- Mitchel and Shannon Wong Eye Institute, Dell Medical School at the University of Texas at Austin, Austin, Texas
| | - Natasha N Kolomeyer
- Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Vikas Chopra
- Doheny and Stein Eye Institutes, David Geffen School of Medicine at UCLA, Los Angeles, California
| | - Pratap Challa
- Department of Ophthalmology, Duke University, Durham, North Carolina
| | - Donald L Budenz
- Department of Ophthalmology, University of North Carolina, Chapel Hill, North Carolina
| | - Michael X Repka
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Flora Lum
- American Academy of Ophthalmology, San Francisco, California.
| |
Collapse
|
5
|
Vera V, Sheybani A, Panarelli JF, Grover DS, Lee J, Craven ER, Samuelson TW, Ahmed IIK. Update on Surgical Techniques Best Practices to Optimize Outcomes Following Gel Stent Implantation. Clin Ophthalmol 2025; 19:325-347. [PMID: 39911142 PMCID: PMC11794994 DOI: 10.2147/opth.s487718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2024] [Accepted: 12/02/2024] [Indexed: 02/07/2025] Open
Abstract
The XEN®45 Glaucoma Treatment System (gel stent; Allergan, an AbbVie company, Irvine, CA, USA) is a minimally invasive bleb-forming surgical device that was originally approved to lower intraocular pressure by diverting the aqueous humor from the anterior chamber to the subconjunctival space (like trabeculectomy) following ab-interno placement. Since approval of the gel stent in multiple countries, the implantation technique has evolved considerably, being performed ab interno or ab externo with open or closed conjunctiva, based on patients' needs and/or surgeons' preferences. Additional technical variations that can facilitate gel stent placement and/or improve outcomes have also emerged. This article aims to increase awareness of these developments to facilitate informed decision-making and improve surgical success and outcomes for patients.
Collapse
Affiliation(s)
| | | | - Joseph F Panarelli
- Department of Ophthalmology, New York University Langone Health, New York, NY, USA
| | | | - James Lee
- Colorado Eye Institute, Colorado Springs, CO, USA
| | | | - Thomas W Samuelson
- Minnesota Eye Consultants, University of Minnesota, Minneapolis, MN, USA
| | | |
Collapse
|
6
|
Pacovska MF, de Amorim-Cabral CLD, Teixeira EGDRM, Kasahara N. The need for more pragmatic trials in glaucoma research. Eur J Ophthalmol 2025; 35:181-188. [PMID: 38602016 DOI: 10.1177/11206721241247428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2024]
Abstract
AIM There have been a number of clinical trials in glaucoma research published in the past two decades. Most of these trials were designed to evaluate very specific issues in selected populations placing them in the explanatory end of the pragmatic-explanatory continuum. The purpose of this study was to assess the level of pragmatism of published randomized controlled trials in glaucoma. METHODS A PubMed search using 'glaucoma' from 1995 to 2022 and randomized controlled trial (RCT) article type was done. Each study was assessed by three independent examiners using the Pragmatic-Explanatory Continuum Indicator Summary version 2 (PRECIS-2) toolkit. Scores were calculated for each study to determine the level of pragmatism. A summed score ≥36 was indicative of a very pragmatic study. RESULTS Thirty-two different articles were included in the analysis. These papers represented 13 different landmark trials. The median PRECIS-2 score was 32 (range, 25 for the Early Manifest Glaucoma Trial (EMGT) to 34 to the Collaborative Normal Tension Glaucoma Study (CNTGS) and the Ocular Hypertension Treatment Study). The Treatment of Advanced Glaucoma Study (TAGS), was considered very pragmatic and scored 33 points. CONCLUSION Despite the number of RCTs in glaucoma, there is still a need for more pragmatic studies.
Collapse
Affiliation(s)
- Mayara Fernanda Pacovska
- Department of Ophthalmology, Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, Brazil
| | | | | | - Niro Kasahara
- Department of Ophthalmology, Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, Brazil
- Santa Casa de Sao Paulo School of Medical Sciences, Sao Paulo, Brazil
| |
Collapse
|
7
|
Lange KM, Sullivan TR, Kasza J, Yelland LN. Performance of mixed effects models and generalized estimating equations for continuous outcomes in partially clustered trials including both independent and paired data. Stat Med 2024; 43:4819-4835. [PMID: 39233370 DOI: 10.1002/sim.10201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 06/19/2024] [Accepted: 08/07/2024] [Indexed: 09/06/2024]
Abstract
Many clinical trials involve partially clustered data, where some observations belong to a cluster and others can be considered independent. For example, neonatal trials may include infants from single or multiple births. Sample size and analysis methods for these trials have received limited attention. A simulation study was conducted to (1) assess whether existing power formulas based on generalized estimating equations (GEEs) provide an adequate approximation to the power achieved by mixed effects models, and (2) compare the performance of mixed models vs GEEs in estimating the effect of treatment on a continuous outcome. We considered clusters that exist prior to randomization with a maximum cluster size of 2, three methods of randomizing the clustered observations, and simulated datasets with uninformative cluster size and the sample size required to achieve 80% power according to GEE-based formulas with an independence or exchangeable working correlation structure. The empirical power of the mixed model approach was close to the nominal level when sample size was calculated using the exchangeable GEE formula, but was often too high when the sample size was based on the independence GEE formula. The independence GEE always converged and performed well in all scenarios. Performance of the exchangeable GEE and mixed model was also acceptable under cluster randomization, though under-coverage and inflated type I error rates could occur with other methods of randomization. Analysis of partially clustered trials using GEEs with an independence working correlation structure may be preferred to avoid the limitations of mixed models and exchangeable GEEs.
Collapse
Affiliation(s)
- Kylie M Lange
- School of Public Health, The University of Adelaide, Adelaide, South Australia, Australia
- Women and Kids Theme, South Australian Health and Medical Research Institute, Adelaide, South Australia, Australia
| | - Thomas R Sullivan
- School of Public Health, The University of Adelaide, Adelaide, South Australia, Australia
- Women and Kids Theme, South Australian Health and Medical Research Institute, Adelaide, South Australia, Australia
| | - Jessica Kasza
- School of Public Health and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
| | - Lisa N Yelland
- School of Public Health, The University of Adelaide, Adelaide, South Australia, Australia
- Women and Kids Theme, South Australian Health and Medical Research Institute, Adelaide, South Australia, Australia
| |
Collapse
|
8
|
Iqbal H, Razzaq A, Zhou D, Lou J, Xiao R, Lin F, Liang Y. Nanomedicine in glaucoma treatment; Current challenges and future perspectives. Mater Today Bio 2024; 28:101229. [PMID: 39296355 PMCID: PMC11409099 DOI: 10.1016/j.mtbio.2024.101229] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 08/19/2024] [Accepted: 09/03/2024] [Indexed: 09/21/2024] Open
Abstract
Glaucoma presents a significant global health concern and affects millions of individuals worldwide and predicted a high increase in prevalence of about 111 million by 2040. The current standard treatment involves hypotensive eye drops; however, challenges such as patient adherence and limited drug bioavailability hinder the treatment effectiveness. Nanopharmaceuticals or nanomedicines offer promising solutions to overcome these obstacles. In this manuscript, we summarized the current limitations of conventional antiglaucoma treatment, role of nanomedicine in glaucoma treatment, rational design, factors effecting the performance of nanomedicine and different types of nanocarriers in designing of nanomedicine along with their applications in glaucoma treatment from recent literature. Current clinical challenges that hinder real-time application of antiglaucoma nanomedicine are highlighted. Lastly, future directions are identified for improving the therapeutic potential and translation of antiglaucoma nanomedicine into clinic.
Collapse
Affiliation(s)
- Haroon Iqbal
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
- National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
- Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, China
| | - Anam Razzaq
- Jiangsu Key Laboratory of Neuropsychiatric Diseases, College of Pharmaceutical Science, Soochow University, Suzhou, 215123, China
| | - Dengming Zhou
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
- National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
| | - Jiangtao Lou
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Run Xiao
- Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, China
| | - Fu Lin
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
- National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
| | - Yuanbo Liang
- State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
- National Clinical Research Center for Ocular Diseases, Eye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
- National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China
| |
Collapse
|
9
|
Murtaza F, Kaba Q, Somani S, Tam ES, Yuen D. Micropulse Transscleral Cyclophotocoagulation in Non-Incisional Eyes with Ocular Hypertension and Primary Open-Angle Glaucoma. Clin Ophthalmol 2024; 18:1295-1312. [PMID: 38751993 PMCID: PMC11095520 DOI: 10.2147/opth.s447875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 04/08/2024] [Indexed: 05/18/2024] Open
Abstract
Purpose To investigate the safety and effectiveness of micropulse transscleral cyclophotocoagulation (MPTSCPC) in non-incisional eyes with ocular hypertension (OHT) and early, moderate, and severe primary open-angle glaucoma (POAG). Methods Retrospective cohort study of eyes that underwent MPTSCPC from 2016 to 2019 at an outpatient clinic in Canada. Eyes were excluded if any incisional procedures, except cataract surgery, were performed prior to MPTSCPC treatment. Laser power ranged from 900 to 2500mW. Results A total of 153 eyes from 93 patients were included (OHT n=22; early POAG n=46; moderate POAG n=35; severe POAG n=50). The baseline IOP was 18.37 ± 4.76mmHg in the total cohort. All cohorts experienced a significant mean IOP reduction by final follow-up (total p<0.001; OHT p=0.003; early POAG p<0.001; moderate POAG p=0.022; severe POAG p=0.015). Overall, 52.9% of eyes achieved an IOP reduction of ≥20% from baseline to final follow-up (OHT 59.1%; early POAG 58.7%; moderate POAG 45.7%; severe POAG 50.0%). There was worsening in best-corrected visual acuity in the total cohort (mean difference=0.11 ± 0.36 logMAR, p=0.11), mostly attributable to cataract progression (34.1% of phakic eyes) and ocular surface disease (7.2%). The number of topical medications and drug classes remained unchanged in the total cohort (p=0.425 and p=0.791, respectively). Twenty-two eyes (14.4%) required retreatment, which provided an additional IOP reduction of 1.26mmHg (p=0.344). By final follow-up, 8 eyes (5.2%) required escalation to incisional procedures. Conclusion MPTSCPC is a safe and effective adjunct IOP-lowering treatment in non-incisional eyes with OHT and POAG.
Collapse
Affiliation(s)
- Fahmeeda Murtaza
- Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | | | - Sohel Somani
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON, Canada
- Uptown Eye Specialists, Brampton, ON, Canada
- Division of Ophthalmology, William Osler Health System, Brampton, ON, Canada
| | - Eric S Tam
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON, Canada
- Uptown Eye Specialists, Brampton, ON, Canada
- Division of Ophthalmology, William Osler Health System, Brampton, ON, Canada
| | - Darana Yuen
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON, Canada
- Uptown Eye Specialists, Brampton, ON, Canada
| |
Collapse
|
10
|
El Helwe H, Samuel S, Falah H, Trzcinski J, Solá-Del Valle DA. Comparing Outcomes of Tube Versus Trabeculectomy Among Patients With Angle-closure Glaucoma. Ophthalmol Glaucoma 2024:S2589-4196(24)00068-1. [PMID: 38636705 DOI: 10.1016/j.ogla.2024.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 03/04/2024] [Accepted: 04/10/2024] [Indexed: 04/20/2024]
Abstract
PURPOSE Compare outcomes of tube shunt surgery (Tube) and trabeculectomy with mitomycin C (Trab-MMC) in patients with angle-closure glaucoma (ACG). DESIGN Retrospective nonrandomized comparative study. PARTICIPANTS A total of 80 eyes from 80 patients with ACG who underwent either Tube (N = 50) or Trab-MMC (N = 30) between January 2015 and January 2022 at Massachusetts Eye and Ear. METHODS Reviewed and analyzed 390 visits from patient charts. MAIN OUTCOME MEASURES Kaplan-Meier (KM) success rates, intraocular pressure (IOP), medication burden, best-corrected visual acuity (BCVA), adjusted hazard ratios (HRs), and complications. RESULTS Baseline demographics were similar between both groups, except for a higher proportion of patients with pseudophakia and prior incisional ocular surgery in the Tube group. The Trab-MMC procedure had significantly higher KM complete success (CS) rates than the Tube procedure, but similar qualified success (QS) rates. Under QS, the cumulative probability of survival was 87% in the Tube group and 83% in the Trab-MMC group at year 1 (P = 0.77), and 75% in the Tube group and 58% in the Trab-MMC group at year 2 (P = 0.14). Under CS, the cumulative probability of survival was 13% in the Tube group and 59% in the Trab-MMC group at year 1 (P < 0.001), and 11% in the Tube group and 41% in the Trab-MMC group at year 2 (P < 0.001). Both Tube and Trab-MMC procedures resulted in significant patterns of IOP and medication reduction from baseline up to 2 years with mean IOP reduced to 12.6 ± 5.9 mmHg on 2.8 ± 1.4 medications after Tube and 12.1 ± 6.6 mmHg on 2.4 ± 1.7 medications after Trab-MMC. Patients who underwent Trab-MMC required less IOP-lowering medications at every follow-up visit up to year 1, but a similar number at year 2. No significant differences were found in IOP reduction, BCVA, or complication rates between groups. CONCLUSIONS We demonstrate that Trab-MMC confers similar IOP reduction and QS rates to Tube placement in patients with ACG. Trab-MMC, however, demonstrated greater medication burden reduction up to 1 year, and more favorable CS rates up to 2 years, while still maintaining similar complication rates to Tube. FINANCIAL DISCLOSURE(S) The author(s) have no proprietary or commercial interest in any materials discussed in this article.
Collapse
Affiliation(s)
- Hani El Helwe
- Harvard Medical School, Massachusetts Eye and Ear, Boston, Massachusetts
| | - Sandy Samuel
- Ophthalmology Department, Wills Eye Hospital, Philadelphia, Pennsylvania
| | - Henisk Falah
- Glaucoma Service, Massachusetts Eye and Ear, Boston, Massachusetts
| | | | | |
Collapse
|
11
|
Alqudah AA, Aleshawi A. Successful Management of Bilateral Uncontrolled Advanced Primary Open Angle Glaucoma in a Pregnant Woman during the Restrictive COVID-19 Lockdown. CLINICAL OPTOMETRY 2024; 16:101-105. [PMID: 38562246 PMCID: PMC10982051 DOI: 10.2147/opto.s451799] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 03/15/2024] [Indexed: 04/04/2024]
Abstract
COVID-19 is a viral illness that can cause severe respiratory symptoms. COVID-19 has caused a worldwide pandemic that necessitated many countries to perform a national lockdown. In Jordan, a lockdown was imposed by the government. During the lockdown, the hospitals were only dealing with outpatient emergency cases, urgent referrals from primary or secondary health institutions, and inpatients whose medical conditions required keeping them admitted. Elective clinics and surgeries were canceled. At the King Abdullah University Hospital (KAUH), which is the only tertiary center in northern Jordan, we dealt with an unusual case of uncontrolled and advanced primary open angle glaucoma in a 38-year-old pregnant female patient. The patient was presented with an intraocular pressure (IOP) of 53 mmHg in the right eye and 40 mmHg in the left eye despite using dorzolamide and timolol eye drops twice daily. The angle was opened in gonioscopy. The decision was made to implant Ahmed glaucoma valves (AGV) in each eye in one session under general anesthesia which was performed successfully. At the last follow-up visit 4 years later, the IOP was maintained at 15 mmHg.
Collapse
Affiliation(s)
- Asem A Alqudah
- Division of Ophthalmology, Department of Special Surgery, Faculty of Medicine, Jordan University of Science and Technology, Irbid, Jordan
| | - Abdelwahab Aleshawi
- Division of Ophthalmology, Department of Special Surgery, Faculty of Medicine, Jordan University of Science and Technology, Irbid, Jordan
| |
Collapse
|
12
|
Panarelli JF, Moster MR, Garcia-Feijoo J, Flowers BE, Baker ND, Barnebey HS, Grover DS, Khatana AK, Lee B, Nguyen T, Stiles MC, Sadruddin O, Khaw PT. Ab-Externo MicroShunt versus Trabeculectomy in Primary Open-Angle Glaucoma: Two-Year Results from a Randomized, Multicenter Study. Ophthalmology 2024; 131:266-276. [PMID: 37769852 DOI: 10.1016/j.ophtha.2023.09.023] [Citation(s) in RCA: 21] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 09/08/2023] [Accepted: 09/19/2023] [Indexed: 10/03/2023] Open
Abstract
PURPOSE To compare the effectiveness and safety of the MicroShunt (Santen Inc) versus trabeculectomy in patients with primary open-angle glaucoma (POAG). DESIGN Prospective, randomized, multicenter trial conducted in the United States and Europe. PARTICIPANTS Adult patients (aged 40-85 years) with mild to severe POAG inadequately controlled on maximum tolerated medical therapy and intraocular pressure (IOP) ≥ 15 mmHg and ≤ 40 mmHg. METHODS Patients were randomized 3:1 to stand-alone MicroShunt implantation (n = 395) or trabeculectomy (n = 132), both augmented with mitomycin C (MMC) 0.2 mg/ml for 2 minutes. MAIN OUTCOME MEASURES The primary effectiveness end point was surgical success, defined as ≥ 20% reduction in mean diurnal IOP from baseline with no increase in glaucoma medications. Secondary end points included changes in mean IOP and medication use from baseline and the need for postoperative interventions. RESULTS At 2 years, the rate of surgical success was lower in the MicroShunt group than in the trabeculectomy group (50.6% vs. 64.4%, P = 0.005). Mean diurnal IOP was reduced from 21.1 ± 4.9 mmHg at baseline to 13.9 ± 3.9 mmHg at 24 months in the MicroShunt group and from 21.1 ± 5.0 mmHg at baseline to 10.7 ± 3.7 mmHg at 24 months in the trabeculectomy group (P < 0.001 compared with baseline in both groups). Mean medication use decreased from 3.1 to 0.9 in the MicroShunt group and from 2.9 to 0.4 in the trabeculectomy group (P < 0.001 compared with baseline in both groups). Adverse events at 2 years were generally similar in the 2 groups, except that hypotony was more common in eyes undergoing trabeculectomy (51.1% vs. 30.9%, P < 0.001). Repositioning or explantation of the implant occurred in 6.8% of MicroShunt patients. The majority of these patients had device removal at the time of subsequent glaucoma surgery. Vision-threatening complications were uncommon in both groups. CONCLUSION At 2 years, both the MicroShunt and trabeculectomy provided significant reductions in IOP and medication use, with trabeculectomy continuing to have greater surgical success. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Bonny Lee
- New York University, New York, New York
| | | | | | | | - Peng T Khaw
- NIHR Moorfields Biomedical Research Centre, Moorfields Eye Hospital and UCL Institute of Ophthalmology, London, England; UCL Institute of Ophthalmology, London, England
| |
Collapse
|
13
|
Chopra V, Takusagawa HL, Rosdahl JA, Sit AJ, Richter GM, Ou Y, Kim SJ, WuDunn D. Aqueous Shunts with Extraocular Reservoir for Open-Angle Adult Glaucoma: A Report by the American Academy of Ophthalmology. Ophthalmology 2024; 131:227-239. [PMID: 38069945 DOI: 10.1016/j.ophtha.2023.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 10/05/2023] [Accepted: 10/05/2023] [Indexed: 01/23/2024] Open
Abstract
PURPOSE To evaluate the recently published literature on the efficacy and safety of the use of aqueous shunts with extraocular reservoir for the management of adult open-angle glaucomas (OAGs). METHODS A search of peer-reviewed literature was last conducted in April 2023 of the PubMed database and included only articles published since the last aqueous shunt Ophthalmic Technology Assessment, which assessed articles published before 2008. The abstracts of these 419 articles were examined, and 58 studies were selected for full-text analysis. After inclusion and exclusion criteria were applied, 28 articles were selected and assigned ratings by the panel methodologist according to the level of evidence. Twenty-five articles were rated level I and 3 articles were rated level II. There were no level III articles. RESULTS Implantation of aqueous shunts with extraocular reservoir can lower intraocular pressure (IOP) by between one-third and one-half of baseline IOP, depending on whether it is undertaken as the primary or secondary glaucoma surgery. Success rates for aqueous shunts were found to be better than for trabeculectomies in eyes with prior incisional surgery. Conversely, in eyes without prior incisional surgery, implantation of aqueous shunts was found to have an overall lower success rate as the primary glaucoma procedure compared with trabeculectomy. Although both valved and nonvalved aqueous shunts with extraocular reservoir were effective, the nonvalved device generally achieved slightly lower long-term IOPs with fewer glaucoma medications and less need for additional glaucoma surgery. Both devices slow the rates of visual field progression with efficacy comparable with that of trabeculectomy. Early aqueous humor suppression after aqueous shunt implantation is recommended for the management of the postoperative hypertensive phase and long-term IOP control. No strong evidence supports the routine use of mitomycin C with aqueous shunt implantation for OAG. CONCLUSIONS Implantation of aqueous shunts with extraocular reservoir, including valved or nonvalved devices, has been shown to be an effective strategy to lower IOP. Strong level I evidence supports the use of aqueous shunts with extraocular reservoir by clinicians for the management of adult OAG. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Vikas Chopra
- Doheny Eye Centers UCLA and Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, California
| | - Hana L Takusagawa
- VA Eugene Healthcare Center, Eugene, Oregon and Casey Eye Institute, Oregon Health & Sciences University, Portland, Oregon
| | - Jullia A Rosdahl
- Department of Ophthalmology, Duke University School of Medicine, Durham, North Carolina
| | - Arthur J Sit
- Mayo Clinic, Department of Ophthalmology, Rochester, Minnesota
| | - Grace M Richter
- Department of Ophthalmology, Southern California Permanente Medical Group, Kaiser Permanente Los Angeles Medical Center, Los Angeles, California; USC Roski Eye Institute, Keck Medicine of University of Southern California, Los Angeles, California
| | - Yvonne Ou
- Department of Ophthalmology, University of California San Francisco, San Francisco, California
| | - Stephen J Kim
- Department of Ophthalmology, Vanderbilt University School of Medicine, Nashville, Tennessee
| | - Darrell WuDunn
- University of Florida College of Medicine-Jacksonville, Department of Ophthalmology, Jacksonville, Florida
| |
Collapse
|
14
|
Shao CG, Gharabagi AP, King J, Webel AD. Sulcus Tube Internal Needle Guidewire Technique for Glaucoma Drainage Device Placement: Improving Surgical Ease and Precision. Ophthalmol Ther 2024; 13:635-643. [PMID: 38060193 PMCID: PMC10787709 DOI: 10.1007/s40123-023-00848-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 10/25/2023] [Indexed: 12/08/2023] Open
Abstract
INTRODUCTION Despite the rise of micro-invasive glaucoma surgery (MIGS), glaucoma drainage device implantation continues to be a mainstay among glaucoma surgical treatment options. Anterior chamber tube placement, while effective in reducing intraocular pressure (IOP), poses corneal endothelial risks. Ciliary sulcus tube placement shows promise in reduced corneal endothelial cell loss, but proper sulcus placement can be challenging. Our study describes the initial safety and effectiveness results using a novel sulcus tube internal needle guidewire (STING) technique for glaucoma drainage device insertion into the ciliary sulcus. METHODS We retrospectively reviewed the charts of all consecutive patients who underwent the STING technique using the Ahmed ClearPath, Ahmed Glaucoma Valve, or Baerveldt glaucoma implant with at least 6 months of follow-up. Demographic characteristics, type of glaucoma, previous medical and surgical treatment, pre- and postoperative IOP, pre- and postoperative medications, complications, and success rates were recorded. RESULTS Out of nine eyes, seven resulted in qualified success (77.8%). Preoperative mean IOP was 23.8 ± 6.3 mmHg, and postoperative IOP decreased significantly to 14.9 ± 3.7 mmHg (p = 0.008). The average number of preoperative medications per patient was 4.4 ± 0.7, while the average number of postoperative medications per patient was reduced significantly to 3.6 ± 1.0 (p = 0.039). CONCLUSION The STING technique is a novel method for placing a glaucoma drainage device into the ciliary sulcus, leading to IOP lowering with minimal complications. The STING technique is designed to improve surgical ease and increase anatomical precision of sulcus tube placement. Video available for this article.
Collapse
Affiliation(s)
- Christine G Shao
- University of Missouri-Columbia School of Medicine, 1 Hospital Dr, Columbia, MO, 65212, USA
| | - Ariess P Gharabagi
- University of Missouri-Columbia Mason Eye Institute, 3215 Wingate Ct Ste 102, Columbia, MO, 65201, USA
| | - Joshua King
- University of Missouri-Columbia Mason Eye Institute, 3215 Wingate Ct Ste 102, Columbia, MO, 65201, USA
| | - Aaron D Webel
- University of Missouri-Columbia Mason Eye Institute, 3215 Wingate Ct Ste 102, Columbia, MO, 65201, USA.
| |
Collapse
|
15
|
Sun CQ, McSoley MJ, Lum F, Chang TC, Gedde SJ, Vanner EA. Tube Versus Trabeculectomy IRIS Registry Study: 1-Year Secondary Treatment Outcomes. Am J Ophthalmol 2023; 256:97-107. [PMID: 37625509 PMCID: PMC11085044 DOI: 10.1016/j.ajo.2023.08.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 08/12/2023] [Accepted: 08/16/2023] [Indexed: 08/27/2023]
Abstract
PURPOSE To describe 1-year secondary outcomes in the Tube Versus Trabeculectomy IRIS® (Intelligent Registry In Sight) Registry Study (TVTIRIS), and to compare to the TVT randomized controlled trial (TVTRCT). DESIGN TVTIRIS was a retrospective cohort study. METHODS The 2013-2017 IRIS Registry was used to identify eyes that received a tube shunt (tube) or trabeculectomy after a previous trabeculectomy and/or cataract surgery and had 1 year of follow-up. The TVTRCT compared a Baerveldt 350-mm2 glaucoma implant to trabeculectomy in similar eyes. RESULTS In the TVTIRIS cohort, the tube (n = 236, 56.3%) and trabeculectomy (n = 183, 43.7%) groups had similar and significant reductions in intraocular pressure (IOP) from baseline to 1 year. In the tube group, IOP (mean ± SD) decreased from 26.6 ± 6.5 mm Hg at baseline to 14.3 ± 4.8 mm Hg at 1 year. In the trabeculectomy group, IOP decreased from 25.3 ± 6.4 mm Hg at baseline to 13.5 ± 5.2 mm Hg at 1 year. The trabeculectomy groups from both studies had similar 1-year IOP reduction (P = .18), although the TVTRCT cohort used fewer medications at all time points (P < .01). There were more pronounced differences in the mean IOP and medications between the tube groups in the 2 studies, presumably due to the inclusion of valved tubes in TVTIRIS. More reoperations occurred in TVTIRIS. CONCLUSIONS The TVTIRIS tube and trabeculectomy groups had comparable 1-year IOP reduction, although trabeculectomy eyes used fewer glaucoma medications. The trabeculectomy group in TVTIRIS and TVTRCT had similar IOP and medication reduction at 1 year. Randomized controlled trials and electronic health record data both provide invaluable insight into surgical outcomes.
Collapse
Affiliation(s)
- Catherine Q Sun
- From the Bascom Palmer Eye Institute (C.Q.S., M.J.M., T.C.C., S.J.G., E.A.V.), Miami, Florida, USA; Department of Ophthalmology (C.Q.S.), University of California, San Francisco, California, USA; F.I. Proctor Foundation (C.Q.S.), University of California, San Francisco, California, USA.
| | - Matthew J McSoley
- From the Bascom Palmer Eye Institute (C.Q.S., M.J.M., T.C.C., S.J.G., E.A.V.), Miami, Florida, USA; University of Miami Miller School of Medicine (M.J.M.), Miami, Florida, USA
| | - Flora Lum
- American Academy of Ophthalmology (F.L.), San Francisco, California, USA
| | - Ta C Chang
- From the Bascom Palmer Eye Institute (C.Q.S., M.J.M., T.C.C., S.J.G., E.A.V.), Miami, Florida, USA
| | - Steven J Gedde
- From the Bascom Palmer Eye Institute (C.Q.S., M.J.M., T.C.C., S.J.G., E.A.V.), Miami, Florida, USA
| | - Elizabeth A Vanner
- From the Bascom Palmer Eye Institute (C.Q.S., M.J.M., T.C.C., S.J.G., E.A.V.), Miami, Florida, USA
| |
Collapse
|
16
|
Han K, Lee J, Moon S. One-Year Outcomes of Ab Externo XEN45 Gel Stent Implantation with an Open Conjunctiva Approach in Patients with Open-Angle Glaucoma. KOREAN JOURNAL OF OPHTHALMOLOGY 2023; 37:353-364. [PMID: 37553094 PMCID: PMC10587460 DOI: 10.3341/kjo.2023.0044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 06/23/2023] [Accepted: 07/27/2023] [Indexed: 08/10/2023] Open
Abstract
PURPOSE This study aimed to evaluate the 1-year surgical outcomes of XEN45 gel stent implantation with an open conjunctiva approach in patients with open-angle glaucoma (OAG). METHODS This retrospective cohort study included 19 eyes of 19 patients who underwent XEN45 gel stent implantation with an open conjunctival approach. Surgical success was defined by intraocular pressure (IOP) ≤18 mmHg and one of the following: IOP reduction ≥30% or reduction of two glaucoma medications with final IOP if baseline IOP ≤18 mmHg. The cumulative probability of success rate was analyzed using Kaplan-Meier survival analysis. Cox proportional hazard regression analysis was used to assess prognostic factors for surgical failure. RESULTS IOP reduced from 32.37 ± 12.08 mmHg preoperatively to 15.14 ± 2.25 mmHg at 1 year (p = 0.001). The number of glaucoma medication reduced from 3.89 ± 0.32 preoperatively to 0.86 ± 1.35 at 1 year (p = 0.001). The success rates were 78.9% at 6 months and 73.7% at 1 year. Eyes with bleb horizontal extent ≥2 clock hours at 1 month postoperatively had a significantly higher success rate (log-rank test, p < 0.001). Greater bleb horizontal extent at 2 weeks and 1 month postoperatively was associated with a lower surgical failure rate (2 weeks: hazard ratio, 0.119; p = 0.024; 1 month: hazard ratio, 0.046; p = 0.007). Bleb needling and additional glaucoma surgeries were necessary in 10 (52.6%) and five eyes (26.3%), respectively. CONCLUSIONS XEN45 gel stent implantation with the open conjunctiva approach is effective in reducing IOP and glaucoma medication for over 1 year in patients with OAG.
Collapse
Affiliation(s)
- Kwangeon Han
- Department of Ophthalmology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan,
Korea
| | - Jiwoong Lee
- Department of Ophthalmology, Pusan National University School of Medicine, Busan,
Korea
- Biomedical Research Institute, Pusan National University Hospital, Busan,
Korea
| | - Sangwoo Moon
- Department of Ophthalmology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan,
Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan,
Korea
| |
Collapse
|
17
|
Khodeiry MM, Elhusseiny AM, Liu X, Sayed MS, Lee RK. Cyclophotocoagulation as a Minimally Invasive Treatment Option for Glaucoma. Int Ophthalmol Clin 2023; 63:125-135. [PMID: 37755447 PMCID: PMC10539019 DOI: 10.1097/iio.0000000000000492] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/28/2023]
Abstract
Historically, the complications and inadequate efficacy of prior cyclodestructive procedures limited their role in glaucoma management. Recent advances in treatment techniques and parameters for laser cyclophotocoagulation has expanded its role in today's glaucoma practice. This review summarizes the role of different cyclophotocoagulation techniques, including continuous wave transscleral cyclophotocoagulation and micropulse transscleral cyclophotocoagulation, in the management of glaucomatous optic neuropathy.
Collapse
Affiliation(s)
- Mohamed M. Khodeiry
- Department of Ophthalmology and Visual Sciences, University of Kentucky College of Medicine, Lexington, Kentucky
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Abdelrahman M. Elhusseiny
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Harvey and Bernice Jones Eye Institute, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Xiangxiang Liu
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | | | - Richard K. Lee
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
18
|
Sheybani A, Vera V, Grover DS, Vold SD, Cotter F, Bedrood S, Sawhney G, Piette SD, Simonyi S, Gu X, Balaram M, Gallardo MJ. Gel Stent Versus Trabeculectomy: The Randomized, Multicenter, Gold-Standard Pathway Study (GPS) of Effectiveness and Safety at 12 Months. Am J Ophthalmol 2023; 252:306-325. [PMID: 36972738 DOI: 10.1016/j.ajo.2023.03.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 03/16/2023] [Accepted: 03/18/2023] [Indexed: 03/28/2023]
Abstract
PURPOSE To compare effectiveness and safety of the gel stent to trabeculectomy in open-angle glaucoma (OAG). DESIGN Prospective, randomized, multicenter, noninferiority study. METHODS Patients with OAG and intraocular pressure (IOP) 15 to 44 mm Hg on topical IOP-lowering medication were randomized 2:1 to gel stent implantation or trabeculectomy. Primary end point (surgical success): percentage of patients at month 12 achieving ≥20% IOP reduction from baseline without medication increase, clinical hypotony, vision loss to counting fingers, or secondary surgical intervention (SSI) in a noninferiority test with 24% margins. Secondary end points (month 12) included mean IOP and medication count, postoperative intervention rate, visual recovery, and patient-reported outcomes (PROs). Safety end points included adverse events (AEs). RESULTS At month 12, the gel stent was statistically noninferior to trabeculectomy (between-treatment difference [Δ], -6.1%; 95% CI, -22.9%, 10.8%); 62.1% and 68.2% achieved the primary end point, respectively (P=.487); mean IOP and medication count reductions from baseline were significant (P<.001); and the IOP change-related Δ (2.8 mm Hg) favored trabeculectomy (P=.024). The gel stent resulted in fewer eyes requiring in-office postoperative interventions (P=.024 after excluding laser suture lysis), faster visual recovery (P≤.048), and greater 6-month improvements in visual function problems (ie, PROs; P≤.022). The most common AEs were reduced visual acuity at any time (gel stent, 38.9%; trabeculectomy, 54.5%) and hypotony (IOP <6 mm Hg at any time) (gel stent, 23.2%; trabeculectomy, 50.0%). CONCLUSIONS At month 12, the gel stent was statistically noninferior to trabeculectomy, per the percentage of patients achieving ≥20% IOP reduction from baseline without medication increase, clinical hypotony, vision loss to counting fingers, or SSI. Trabeculectomy achieved a statistically lower mean IOP, numerically lower failure rate, and numerically lower need for supplemental medications. The gel stent resulted in fewer postoperative interventions, better visual recovery, and fewer AEs.
Collapse
Affiliation(s)
- Arsham Sheybani
- Washington University School of Medicine (A.S.), St Louis, Missouri, USA.
| | - Vanessa Vera
- Allergan, an AbbVie company (V.V.), Irvine, California, USA
| | | | | | - Frank Cotter
- Vistar Eye Center (F.C.), Roanoke, Virginia, USA
| | - Sahar Bedrood
- Acuity Eye Group (S.B.), Arcadia, California, USA; Advanced Vision Care (S.B.), Los Angeles, California, USA
| | | | | | | | - Xuemin Gu
- AbbVie (X.G.), Madison, New Jersey, USA
| | - Mini Balaram
- Nethra Consulting LLC (M.B.), Princeton, New Jersey, USA
| | | |
Collapse
|
19
|
Iris abnormalities may influence the efficacy and filtration strategies of Posner-Schlossman syndrome: a retrospective study involving trabeculectomy, ExPRESS and Ahmed valve implants. Graefes Arch Clin Exp Ophthalmol 2023; 261:791-801. [PMID: 36303060 DOI: 10.1007/s00417-022-05865-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 09/26/2022] [Accepted: 10/07/2022] [Indexed: 11/04/2022] Open
Abstract
PURPOSE To evaluate and compare the one-year efficacy and influencing factors of different filtration surgeries on Posner-Schlossman syndrome (PSS) patients. METHODS A retrospective study enrolling 91 PSS patients who underwent filtering surgeries and were followed for at least one year. Unilateral PSS was diagnosed as recurrent attacks of mild, unilateral, non-granulomatous anterior uveitis, elevated intraocular pressure (IOP), keratic precipitates (KPs) on the corneal endothelium, open angle, no posterior synechia, and no inflammatory lesions in the posterior segment; the IOP and anterior segment returned to normal between attacks. Medical histories and thorough ocular examination results were collected. Trabeculectomy and ExPRESS were chosen as the first line and AGV was considered for those under high risk of fibrosis. Follow-up data, mainly IOP, best-corrected visual acuity (BCVA), and anterior segment manifestations at the 1st week, 6th month, and 12th month were generated and analyzed. Iris abnormalities were determined by depigmentation or atrophic changes on the anterior segment photograph. Complete surgical success was defined as 5 mmHg < IOP ≤ 21 mmHg without IOP-lowering drug or needle revision; qualified surgical success was defined as 5 mmHg < IOP ≤ 21 mmHg with IOP-lowering drugs or needle revisions. Survival analysis was performed to obtain the success rates. RESULTS At the 12th month, the complete surgical success rate of trabeculectomy (N = 54), ExPRESS (N = 23), and AGV group (N = 14) was 58.97% (95%CI 46.91-77.09%), 84.21% (95%CI 68.33-100.87%), and 100%; the qualified success rate was 71.79% (95%CI 62.46-88.34%), 89.47% (95%CI 77.07-103.33%), and 100%, respectively. Patients undergoing trabeculectomy experienced the largest decline of BCVA (from 0.58±0.46 to 1.01±0.51, P < .05); the trabeculectomy group endured the highest IOP (20.84±9.92 mmHg) compared to ExPRESS (14.51±2.86 mmHg, P < .05) and AGV group (13.17±3.32 mmHg, P < .05). At the 12th month, in the ExPRESS group, patients with iris abnormalities had higher IOP than the normal ones (15.65±2.05 mmHg, 12.93±3.17 mmHg, P < .05). ExPRESS helped patients with iris abnormalities maintain lower IOP than trabeculectomy (15.65±2.05 mmHg, 22.52±10.67 mmHg, P < .05). Three patients developed hypotony at the 3rd month (1 in ExPRESS and 2 in trabeculectomy group). CONCLUSION AGV and ExPRESS performed better than trabeculectomy in PSS patients in terms of IOP and success rate. Iris abnormalities might influence the postoperative IOP and this may be valuable in guiding filtration strategies. TRIAL REGISTRATION Chinese Clinical Trial Registry (No. ChiCTR1800017532, date: 2018/08/02).
Collapse
|
20
|
Ciociola EC, Yang SA, Hall N, Lorch AC, Miller JW, Friedman DS, Boland MV, Elze T, Zebardast N. Effectiveness of Trabeculectomy and Tube Shunt with versus without Concurrent Phacoemulsification: Intelligent Research in Sight Registry Longitudinal Analysis. Ophthalmol Glaucoma 2023; 6:42-53. [PMID: 35840047 PMCID: PMC9839888 DOI: 10.1016/j.ogla.2022.07.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 06/27/2022] [Accepted: 07/05/2022] [Indexed: 01/27/2023]
Abstract
OBJECTIVE To determine the effectiveness of trabeculectomy and glaucoma drainage device (GDD) surgery performed with concurrent phacoemulsification compared with stand-alone procedures. DESIGN Multicenter retrospective cohort study. PARTICIPANTS Patients in the Intelligent Research in Sight Registry who underwent trabeculectomy or GDD from 2013 through 2019. METHODS The Kaplan-Meier survival analysis was used to determine reoperation rates. Reoperation was defined as any subsequent glaucoma surgery occurring 1 month to 3 years after the initial procedure. Multivariable Cox proportional hazard models were used to determine reoperation risk factors. MAIN OUTCOME MEASURES Reoperation rate, intraocular pressure (IOP), visual acuity, reoperation procedure type, postoperative complications, and predictors of surgical failure. RESULTS A total of 117 697 eyes undergoing glaucoma surgery alone and 35 657 eyes undergoing surgery with phacoemulsification were included. The cumulative reoperation rates at postoperative years 1 and 3 were 4.9% and 11.5%, respectively, for trabeculectomy alone and 3.0% and 7.3%, respectively, for trabeculectomy combined with phacoemulsification (P < 0.001). The reoperation rates at postoperative 1 and 3 years were 3.8% and 7.8%, respectively, for GDD alone and 2.1% and 5.4%, respectively, for GDD with phacoemulsification (P < 0.001). Stand-alone procedures achieved greater IOP reduction by percentage change from baseline (trabeculectomy alone, 35.3% vs. trabeculectomy with phacoemulsification, 23.1%, P < 0.001; and GDD alone, 36.0% vs. GDD with phacoemulsification, 29.3%; P < 0.001). Visual acuity improved by 0.12 logarithm of the minimum angle of resolution (logMAR) (95% confidence interval [CI], 0.11-0.12) and 0.10 logMAR (95% CI, 0.08-0.11) after trabeculectomy and GDD with phacoemulsification and declined by 0.15 logMAR (95% CI, 0.14-0.15) and 0.12 logMAR (95% CI, 0.11-0.12) after stand-alone trabeculectomy and GDD. The overall documented complication rate was 2.9% for GDD and 1.4% for trabeculectomy. Age, sex, race, ethnicity, baseline IOP, and glaucoma diagnosis and severity were associated with surgical failure risk. The most common reoperation procedure was GDD. CONCLUSIONS Reoperation rates within the first 3 years after trabeculectomy and GDD with and without phacoemulsification were low. Trabeculectomy and GDD with phacoemulsification had lower reoperation rates than those with stand-alone procedures. However, stand-alone procedures resulted in greater IOP reduction compared with combined procedures. Postoperative complications were uncommon overall. Patient age, sex, race, ethnicity, baseline IOP, and glaucoma diagnosis and severity were associated with surgical success.
Collapse
Affiliation(s)
| | - Shuang-An Yang
- Department of Ophthalmology, Taipei City Hospital, Renai Branch, Taipei, Taiwan
| | - Nathan Hall
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Alice C Lorch
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Joan W Miller
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - David S Friedman
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Michael V Boland
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Tobias Elze
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Nazlee Zebardast
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts.
| |
Collapse
|
21
|
Kanadani FN, de F Campos L, Dorairaj S, Prata TS. Transscleral Cyclophotocoagulation: New Perspectives for Uncontrolled Glaucoma Management. J Curr Glaucoma Pract 2023; 17:1-2. [PMID: 37228313 PMCID: PMC10203331 DOI: 10.5005/jp-journals-10078-1398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023] Open
Abstract
How to cite this article: Kanadani FN, F Campos LD, Dorairaj S, et al. Transscleral Cyclophotocoagulation: New Perspectives for Uncontrolled Glaucoma Management. J Curr Glaucoma Pract 2023;17(1):1-2.
Collapse
Affiliation(s)
- Fabio N Kanadani
- Department of Ophthalmology, Glaucoma Institute, Belo Horizonte, Minas Gerais, Brazil; Department of Ophthalmology, Mayo Clinic, Jacksonville, Florida, United States of America; Department of Ophthalmology, Federal University of São Paulo, São Paulo, SP, Brazil
| | - Lilian de F Campos
- Department of Ophthalmology, Glaucoma Institute, Belo Horizonte, Minas Gerais, Brazil
| | - Syril Dorairaj
- Department of Ophthalmology, Mayo Clinic, Jacksonville, Florida, United States of America
| | - Tiago S Prata
- Department of Ophthalmology, Glaucoma Institute, Belo Horizonte, Minas Gerais, Brazil; Department of Ophthalmology, Mayo Clinic, Jacksonville, Florida, United States of America; Department of Ophthalmology, Federal University of São Paulo, São Paulo, SP, Brazil; Glaucoma Sector, HMO, Opty Group, Brazil
| |
Collapse
|
22
|
Vukmirovic A, Ong J, Mukhtar A, Yu D, Morgan WH. Outcomes of 45 μm gelatin stent surgery over 24-month follow-up. Clin Exp Ophthalmol 2023; 51:19-30. [PMID: 36287080 PMCID: PMC10946756 DOI: 10.1111/ceo.14181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 10/06/2022] [Accepted: 10/21/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND The main objectives of this study were to determine whether known risk factors for trabeculectomy failure similarly influence gelatin stent outcomes and to identify surgical factors which may optimise success. METHODS A retrospective, observational study was conducted at a single centre in Perth, Western Australia over 24 months. Two-hundred and sixty-two eyes of 207 patients underwent XEN-45 stent surgery with various forms of glaucoma. Surgical and postoperative data on subjects undergoing XEN-45 stent surgery was collated. Intraocular pressure (IOP) reduction success was determined using three criteria: 1; IOP <18 mm Hg, 2: IOP <15 mm Hg and 3: >25% IOP reduction from baseline. Kaplan-Meier, mixed effects Cox Proportional hazard model and Chi-Square test were used to measure survival of functioning stents. RESULTS The success rates at a maximum of 2 years after surgery by criteria 1, 2 and 3 were 61.3%, 26.2% and 28.9% in primary open angle glaucoma (n = 243), 18.8%, 16.9%, 21.4% in angle closure glaucoma (n = 11), 0%, 0%, 66.7% in congenital glaucoma (n = 5) and 0% in uveitic glaucoma (n = 3). No significant reduction in success was found in those eyes that had prior ocular surgery (all p > 0.07). CONCLUSIONS Prior cataract or trabeculectomy surgery does not appear to adversely affect gelatin stent outcomes over 2 years follow up. Gelatin stent surgery appears to have less IOP reduction effect compared to trabeculectomy at 2 years.
Collapse
Affiliation(s)
| | - Jessica Ong
- Lions Eye InstitutePerthWestern AustraliaAustralia
- Ophthalmology departmentRoyal Perth HospitalPerthWestern AustraliaAustralia
| | - Aqif Mukhtar
- Lions Eye InstitutePerthWestern AustraliaAustralia
| | - Dao‐Yi Yu
- Lions Eye InstitutePerthWestern AustraliaAustralia
- Ophthalmology departmentRoyal Perth HospitalPerthWestern AustraliaAustralia
- Centre for Ophthalmology and Visual ScienceUniversity of Western AustraliaPerthWestern AustraliaAustralia
| | - William H. Morgan
- Lions Eye InstitutePerthWestern AustraliaAustralia
- Ophthalmology departmentRoyal Perth HospitalPerthWestern AustraliaAustralia
- Centre for Ophthalmology and Visual ScienceUniversity of Western AustraliaPerthWestern AustraliaAustralia
| |
Collapse
|
23
|
Qiu M, Avdagic E, Ramulu PY, Golnik K, Boland MV. Ophthalmology Surgical Assessment of Tube Shunt Glaucoma Surgery. Ophthalmol Glaucoma 2023; 6:100-105. [PMID: 35760331 DOI: 10.1016/j.ogla.2022.06.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 06/15/2022] [Accepted: 06/17/2022] [Indexed: 01/25/2023]
Abstract
PURPOSE To develop an internationally standardized and validated tool to assess skill in performing tube shunt surgery. DESIGN A panel of 6 glaucoma surgeons developed a tool for assessing tube shunt surgery using a modified Dreyfus scale for skill acquisition. The tool was reviewed by a panel of 10 international content experts, and their comments were incorporated into the final rubric. PARTICIPANTS A different panel of 8 international glaucoma specialists independently graded videos of surgical procedures performed by 6 surgeons at various levels of ophthalmic training. MAIN OUTCOME MEASURES Inter-rater reliability for each step in the rubric was calculated. RESULTS The tube shunt rubric contained 13 steps specific to tube shunt surgery and 7 global indices. The Cronbach α statistic, a measure of internal reliability, ranged from 0.75 to 0.97, indicating strong internal reliability for all 13 steps. CONCLUSIONS The tube shunt assessment tool has face validity, content validity, and interobserver reliability, and can be used to assess tube shunt surgery skills. Further studies are required to determine predictive and construct validity.
Collapse
Affiliation(s)
- Mary Qiu
- Department of Ophthalmology and Visual Science, University of Chicago, Chicago, Illinois.
| | - Ema Avdagic
- Department of Ophthalmology and Visual Science, University of Chicago, Chicago, Illinois
| | - Pradeep Y Ramulu
- Wilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland
| | - Karl Golnik
- University of Cincinnati and Cincinnati Eye Institute, Cincinnati, Ohio
| | - Michael V Boland
- Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
24
|
Papadopoulos K, Schröder FM, Sekundo W. Long-term surgical outcomes of two different Ahmed Valve implantation techniques in refractory glaucoma: Scleral flap vs scleral tunnel. Eur J Ophthalmol 2023; 33:297-306. [PMID: 35473453 DOI: 10.1177/11206721221097176] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
PURPOSE To compare the outcomes and complications of the partial-thickness scleral flap technique to the long scleral tunnel technique in patients who underwent mitomycin C (MMC)-augmented Ahmed glaucoma valve (AGV) implantation. PATIENTS AND METHODS In this retrospective study, we reviewed 139 eyes of 137 patients with refractory glaucoma who underwent AGV-Model FP7 implantation. The eyes were divided into the scleral flap group (n = 74) and the scleral tunnel group (n = 65). RESULTS The mean follow-up was 57.91 ± 18.18 months for the flap and 61.18 ± 15.13 months for the tunnel group (p = 0.2499). The postoperative intraocular pressure (IOP) at 1 to 6 years was significantly lower than the baseline IOP in each group (p < 0.001). The average number of postoperative glaucoma medications decreased in the tunnel group (p = 0.0001) and in the flap group (p = 0.6194) compared to baseline. No statistically significant differences in postoperative visual acuity (p = 0.6396) and cumulative success (p = 0.054) were noted between the two groups. Conjunctival erosion or tube migration only occurred in the flap group. Significantly more reoperations were performed in the flap than in the tunnel group (p = 0.048). CONCLUSIONS Both MMC-augmented AGV tube implantation methods lowered IOP. The flap technique was associated with higher rates of postoperative serious complications and more reoperations than the tunnel technique. Previous glaucoma surgery and the technique used to implant the surgical tube proved to be significant risk factors for conjunctival erosion.
Collapse
Affiliation(s)
- Kosmas Papadopoulos
- Department of Ophthalmology, Faculty of Medicine, 61061Philipps University of Marburg, Marburg, Germany
| | - Frank Michael Schröder
- Department of Ophthalmology, Faculty of Medicine, 61061Philipps University of Marburg, Marburg, Germany
| | - Walter Sekundo
- Department of Ophthalmology, Faculty of Medicine, 61061Philipps University of Marburg, Marburg, Germany
| |
Collapse
|
25
|
Jayasri P, Kaliaperumal S, Behera G, Stephen M. Safety and efficacy of Aurolab aqueous drainage implant in refractory glaucoma: A prospective study. Indian J Ophthalmol 2022; 70:4212-4216. [PMID: 36453316 PMCID: PMC9940568 DOI: 10.4103/ijo.ijo_1391_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Purpose This study was conducted to assess the intraocular pressure (IOP) control and postoperative complications following a non-valved glaucoma drainage device (GDD) surgery in refractory glaucoma. Methods This was a prospective interventional study conducted on patients with glaucoma refractory to maximal medications or failed surgical treatment who underwent Aurolab aqueous drainage implant (AADI; Aurolabs, India) surgery. Primary outcome measures were IOP control, postoperative complications, and reduction in the number of antiglaucoma medications (AGM). Results Thirty-four eyes were analyzed and the mean follow-up was 16.06 ± 5.63 months. The preoperative median (Q1, Q3) IOP was 31 mmHg (28, 36.5) which decreased to 12 mmHg (12, 14) at 6 months postoperatively. The median (Q1, Q3) number of AGMs decreased from 3 (3, 4) to 0 (0, 1). Significant complications like implant extrusion and tube exposure were noted in two eyes. The total success and failure rates at 6 months were 91.1% and 8.8%, respectively. Conclusion AADI is effective in achieving target IOP and significantly reduces the use of AGMs with good safety in the short term. Long-term follow-up studies are needed to assess long-term IOP control and cost-effectiveness.
Collapse
Affiliation(s)
- P Jayasri
- Department of Ophthalmology, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India
| | - Subashini Kaliaperumal
- Department of Ophthalmology, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India,Correspondence to: Prof. Subashini Kaliaperumal, Department of Ophthalmology, JIPMER, Puducherry - 605 006, India. E-mail:
| | - Geeta Behera
- Department of Ophthalmology, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India
| | - Mary Stephen
- Department of Ophthalmology, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India
| |
Collapse
|
26
|
Majoulet A, Scemla B, Hamard P, Brasnu E, Hage A, Baudouin C, Labbé A. Safety and Efficacy of the Preserflo ® Microshunt in Refractory Glaucoma: A One-Year Study. J Clin Med 2022; 11:jcm11237086. [PMID: 36498660 PMCID: PMC9739914 DOI: 10.3390/jcm11237086] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 11/22/2022] [Accepted: 11/23/2022] [Indexed: 12/02/2022] Open
Abstract
Purpose: To evaluate the safety and efficacy of Preserflo® microshunt implantation in eyes with refractory glaucoma. Methods: In this retrospective study, a cohort of patients who underwent Preserflo® microshunt implantation between April 2019 and August 2020 for refractory glaucoma were evaluated. At the time of surgery, all eyes had uncontrolled intraocular pressure (IOP) despite maximally tolerated medical therapy and at least one previous failed glaucoma filtering surgery. The primary outcome was a complete success, defined as postoperative IOP ≤ 21 mm Hg with an IOP reduction ≥ 20% and no repeat filtering surgery. The secondary outcome was qualified success, defined as a complete success with the use of antiglaucoma medications. The rates of needling, bleb repair, and postoperative complications were also recorded. Results: Forty-seven eyes with a mean preoperative IOP of 30.1 ± 7.1 mm Hg and a mean of 3.4 ± 1 glaucoma medications were included. The mean number of previous surgeries prior to microshunt implantation was 2.3 ± 1.3. After 1 year, the mean IOP was significantly reduced to 18.8 ± 4.6 mm Hg, with the mean number of medications significantly reduced to 1.4 ± 1.2. Complete success was achieved in 35% of eyes, and a qualified success in 60% of eyes. A decrease in IOP of at least 30% was found in 55% of eyes. Needling or bleb repair was performed in 49% of eyes. Complications were minimal and transient, except for one eye which presented with tube extrusion, and another eye with a transected tube. A repeat glaucoma surgery had to be performed in 17% of eyes. Conclusions: The Preserflo® Microshunt provided moderate success but a significant reduction in IOP, with a good safety profile after one year of follow-up in eyes at high risk for failure of filtering surgery.
Collapse
Affiliation(s)
- Alexandre Majoulet
- Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, INSERM-DHOS CIC 1423, 75012 Paris, France
- Department of Ophthalmology III, Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, 75012 Paris, France
| | - Benjamin Scemla
- Department of Ophthalmology, Ambroise Paré Hospital, AP-HP, UVSQ, Paris Saclay University, 91190 Gif-sur-Yvette, France
| | - Pascale Hamard
- Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, INSERM-DHOS CIC 1423, 75012 Paris, France
- Department of Ophthalmology III, Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, 75012 Paris, France
| | - Emmanuelle Brasnu
- Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, INSERM-DHOS CIC 1423, 75012 Paris, France
- Department of Ophthalmology III, Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, 75012 Paris, France
| | - Alexandre Hage
- Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, INSERM-DHOS CIC 1423, 75012 Paris, France
- Department of Ophthalmology III, Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, 75012 Paris, France
| | - Christophe Baudouin
- Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, INSERM-DHOS CIC 1423, 75012 Paris, France
- Department of Ophthalmology III, Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, 75012 Paris, France
- Department of Ophthalmology, Ambroise Paré Hospital, AP-HP, UVSQ, Paris Saclay University, 91190 Gif-sur-Yvette, France
| | - Antoine Labbé
- Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, INSERM-DHOS CIC 1423, 75012 Paris, France
- Department of Ophthalmology III, Quinze-Vingts National Ophthalmology Hospital, IHU FOReSIGHT, 75012 Paris, France
- Department of Ophthalmology, Ambroise Paré Hospital, AP-HP, UVSQ, Paris Saclay University, 91190 Gif-sur-Yvette, France
- Correspondence: ; Tel.: +33-1-40021308; Fax: +33-1-40021399
| |
Collapse
|
27
|
Hindi I, Berkowitz E, Waizer I, Tiosano B. Efficacy of the XEN45 Implant in Advanced to End-stage Glaucoma Patients. J Curr Glaucoma Pract 2022; 16:84-90. [PMID: 36128085 PMCID: PMC9452713 DOI: 10.5005/jp-journals-10078-1364] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 12/06/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose To report the efficacy of the XEN45 implant in advanced to end-stage glaucoma patients, after a 6 months follow-up. Methods Retrospective, noncomparative electronic health record audit of patients who had undergone an XEN45 procedure. The main outcome measures were intraocular pressure (IOP) reduction and the number of antihypertensive medications. Secondary outcome measures were the rates of early postoperative complications. Complete and qualified success; failure and hypotony were defined according to the World Glaucoma Association guidelines (Shaarawy TM et al.). Needling rates and short-term complications were assessed and a subgroup analysis was performed. Results A total of 39 eyes with advanced to end stage-glaucoma were included. Twenty eyes (51%) had undergone combined cataract surgery and 19 (49%), the XEN45 procedure alone. Mean IOP decreased from 19.67 ± 7.87 mm Hg to 13.18 ± 6.09 mm Hg; the number of medications decreased from a median use of 4 (IQR 2–5) to 0 (IQR 0–1). Complete success was achieved in 24 (61.5%) of the eyes, qualified success in 10 (25.6%), and failure in five (12.82%). Needling was required in 15 (38.46%) of the eyes at 6 months. Choroidal detachment occurred in eight (20.51%) eyes, numerical hypotony (IOP ≤ 5 mm Hg) at day 1 was noted in seven (17.95%) eyes with a full resolution by 2 weeks. Conclusion In this short-term follow-up, we have seen that XEN45 is a viable, effective, and safe procedure utilized in advanced to end-stage glaucoma patients. Treating cases of significant hypotony using AC reformation with sulfur hexafluoride (SF6) is a safe and effective procedure. How to cite this article Hindi I, Berkowitz E, Waizer I, et al. Efficacy of the XEN45 Implant in Advanced to End-stage Glaucoma Patients. J Curr Glaucoma Pract 2022;16(2):84-90.
Collapse
Affiliation(s)
- Isaac Hindi
- Department of Ophthalmology, Hillel Yaffe Medical Center, Hadera, Israel; The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Israel Institute of Technology, Haifa, Israel
- Isaac Hindi, Department of Ophthalmology, Hillel Yaffe Medical Center, Hadera, Israel; The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Israel Institute of Technology, Haifa, Israel, Phone: +972 0584062215, e-mail:
| | - Eran Berkowitz
- Department of Ophthalmology, Hillel Yaffe Medical Center, Hadera, Israel; The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Israel Institute of Technology, Haifa, Israel
| | - Inbar Waizer
- Department of Ophthalmology, Hillel Yaffe Medical Center, Hadera, Israel; The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Israel Institute of Technology, Haifa, Israel
| | - Beatrice Tiosano
- Department of Ophthalmology, Hillel Yaffe Medical Center, Hadera, Israel; The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
28
|
Factors associated with vision loss in Black or Hispanic patients 1 year after standalone or combined Ahmed glaucoma valve surgery. Graefes Arch Clin Exp Ophthalmol 2022; 260:3565-3575. [PMID: 36008495 DOI: 10.1007/s00417-022-05804-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 07/12/2022] [Accepted: 07/19/2022] [Indexed: 11/04/2022] Open
Abstract
PURPOSE To determine factors associated with vision loss 1 year after Ahmed glaucoma valve (AGV) surgery in Black or Hispanic patients, who bear disproportionate glaucoma burdens yet have been underrepresented in pivotal trials. METHODS This retrospective study included Black or Hispanic patients who received AGVs standalone or combined with phacoemulsification and/or cyclodestructive lasers. Univariate and multivariate generalized estimating equations evaluated the effects of baseline, surgical, and postoperative factors on vision loss of two Snellen lines or more at the 1-year follow-up visit. The primary term was the hypertensive phase (HP), which signified an intraocular pressure (IOP) reading > 21 mmHg within the first 3 postoperative months after reduction below 22 in the first week, without other tube malfunction. RESULTS Of 241 eyes from 186 patients, vision loss of ≥ 2 lines at the 1-year follow-up visit occurred in 21.6% (N = 52). Vision loss of ≥ 2 lines occurred in 52.5% of eyes at week 1, 36.9% of eyes at month 1, and 27.0% of eyes at month 3. Between 6 months and 1 year, vision loss frequencies stabilized. In the multivariate model, HP (OR = 4.71 (2.14, 10.38)), total quadrants with split fixation (1.47 (1.20, 1.81)), follow-up non-glaucomatous eye pathology (2.89 (1.44, 5.80)), and concurrent cataract surgery (0.42 (0.22, 0.82)) each met significance (p < 0.05). CONCLUSION Post-AGV vision loss in the early follow-up period among Black or Hispanic patients was often transient. Hypertensive phase and split fixation each increased the odds of vision loss at 1 year, while concurrent cataract surgery decreased the odds.
Collapse
|
29
|
A Bakr M, A Moustafa U, Al-Subaie M, A Alfayyadh M. The role trans-sclera MP-CPC as a primary treatment option in congenital glaucoma management. EXPERT REVIEW OF OPHTHALMOLOGY 2022. [DOI: 10.1080/17469899.2022.2108790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Affiliation(s)
- Medhat A Bakr
- Ophthalmology Department (Glaucoma Section), Immam Abdulrahman Bin Faisal University, King Fahd University Hospital, Al Khobar, Kingdom of Saudi Arabia
| | - Ussama A Moustafa
- Dhahran Eye Specialist Hospital (DESH), Ministry of Health, Hanoi, Kingdom of Saudi Arabia
| | - Majedd Al-Subaie
- Dhahran Eye Specialist Hospital (DESH), Ministry of Health, Hanoi, Kingdom of Saudi Arabia
| | - Mohammed A Alfayyadh
- Prince Mutaib Bin Abdulaziz Hospital, Aljouf, Ministry of Health, Hanoi, Kingdom of Saudi Arabia
| |
Collapse
|
30
|
Massote JA, Oliveira VDMM, Cronemberger S. Glaucoma drainage devices. REVISTA BRASILEIRA DE OFTALMOLOGIA 2022. [DOI: 10.37039/1982.8551.20220041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
31
|
AlJaloud A, AlHilali S, Edward DP, Ahmad K, Malik R. Preliminary Surgical Outcomes of a Trimmed-Plate Aurolab Aqueous Drainage Implant (AADI) in Eyes at High Risk of Hypotony. Clin Ophthalmol 2022; 16:1487-1496. [PMID: 35592670 PMCID: PMC9113450 DOI: 10.2147/opth.s343378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 03/04/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose We describe the technique of trimming the 350 mm2 AADI glaucoma shunt plate and report preliminary results that test the hypothesis that the IOP-lowering efficacy of the trimmed AADI glaucoma shunt is comparable to the Baerveldt 250 mm2 glaucoma drainage implant with a comparable safety profile to the standard AADI implant. Methods Consecutive patients who had received the modified trimmed-plate AADI, standard AADI and Baerveldt 250 mm2 were included in the study. This included patients with refractory or primary or secondary glaucoma of all ages and eyes with and without previous glaucoma surgery. The decision for trimming the AADI plate was made according to the surgeon’s perceived risk of hypotony. Pre-operative, intraoperative and post-operative data were collected from the hospital electronic medical record system. Surgical success was defined as IOP ≥5 mmHg and ≤21 mmHg on two consecutive visits after 3 months, whilst maintaining at least LP vision and avoiding re-operation for glaucoma. Results The sample consisted of 69 eyes (19 with trimmed-plate AADI implant; 36 eyes with the standard AADI implant and 14 eyes who received a BGI-250). The mean IOP reduction at 1 year was 15 mmHg for the Baerveldt-250, 10 mmHg for the AADI and 13 mmHg for the trimmed-plate AADI. The surgical success rate of the implants over 1 year was 85.7% (95% CI, 53.9–96.2%) for BGI-250, 81.5% (62.6–91.5%) for standard AADI and 78.2% (51.7–91.3%) for the trimmed AADI. Conclusion Trimming the plate of the AADI manually may provide a safe and low-cost method of obtaining a successful surgical outcome in eyes at high risk of hypotony.
Collapse
Affiliation(s)
- Ahmad AlJaloud
- Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
- King Abdullah bin AbdulAziz University Hospital, Riyadh, Saudi Arabia
| | - Sara AlHilali
- Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
| | - Deepak P Edward
- Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
- University of Illinois Eye and Ear Infirmary Chicago, Chicago, IL, USA
| | - Khabir Ahmad
- Research Department, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
- Correspondence: Khabir Ahmad, Research Department, King Khaled Eye Specialist Hospital, Al Aruba Branch Road, Riyadh, 12329, Saudi Arabia, Tel +966 11 482 1308, Email
| | - Rizwan Malik
- Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
- Department of Ophthalmology and Visual Sciences, University of Alberta, Edmonton, AB, Canada
| |
Collapse
|
32
|
Grover DS, Kahook MY, Seibold LK, Singh IP, Ansari H, Butler MR, Smith OU, Sawhney GK, Van Tassel SH, Dorairaj S. Clinical Outcomes of Ahmed ClearPath Implantation in Glaucomatous Eyes: A Novel Valveless Glaucoma Drainage Device. J Glaucoma 2022; 31:335-339. [PMID: 35249988 DOI: 10.1097/ijg.0000000000002013] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 02/08/2022] [Indexed: 11/25/2022]
Abstract
PRCIS Designed with novel features to facilitate implantation and improve safety, the Ahmed ClearPath (ACP) glaucoma drainage device (GDD) provided intraocular pressure (IOP) reduction comparable with other GDDs in eyes with refractory glaucoma in a multicenter retrospective study. PURPOSE To present clinical outcomes with a novel valveless GDD (ACP, New World Medical). The 250 and 350 mm2 models feature a contoured plate for optimal globe apposition, anteriorized suture points to facilitate suturing to the globe, and a prethreaded 4-0 polypropylene ripcord suture. METHODS This was a multicenter retrospective analysis of eyes with medically and/or surgically uncontrolled glaucoma implanted with the 250 or 350 mm2 ACP either as a standalone procedure or in combination with other procedures. Pre-, intra-, and postoperative data through 6 months were collected. RESULTS A total of 104 eyes (100 subjects) received the ACP by 10 US surgeons, 63.5% of which had primary open-angle glaucoma and 62.5% had severe glaucoma. Mean baseline IOP was 26.3 (9.0) mm Hg and mean medication use was 3.9 (1.3). Through 6 months' follow-up, mean IOP ranged from 13.6 to 16.7 mm Hg and mean medication use from 0.9 to 1.9 medications (P<0.0001 at all timepoints for each outcome measure). At 6 months, mean IOP was 13.7 mm Hg (-13.0 mm Hg, 43.0%, P<0.0001) and mean medication use was 1.9 medications per eye (-2.1, 47.7%, P<0.0001). Common adverse events included anterior chamber inflammation (16.3%), hyphema (15.4%), and hypotony (6.7%). CONCLUSION The new ACP appears to be safe and efficacious as a standalone procedure or in combination with other procedures for uncontrolled glaucoma, and may be considered as a GDD option for patients in whom its unique design may facilitate the implantation process.
Collapse
Affiliation(s)
| | - Malik Y Kahook
- Department of Ophthalmology, Sue Anschutz-Rodgers Eye Center, University of Colorado School of Medicine, Aurora, CO
| | - Leonard K Seibold
- Department of Ophthalmology, Sue Anschutz-Rodgers Eye Center, University of Colorado School of Medicine, Aurora, CO
| | - Inder Paul Singh
- The Eye Centers of Racine and Kenosha, Kenosha, WI
- The Chicago Medical School, North Chicago, IL
| | | | | | | | | | | | | |
Collapse
|
33
|
Slagle G, Griffin J, Sponsel WE. Rotational extraction of incarcerated iris (REII): a slit lamp technique to reduce incarcerated iris after nonpenetrating deep sclerectomy for glaucoma. Graefes Arch Clin Exp Ophthalmol 2022; 260:3331-3337. [PMID: 35441876 DOI: 10.1007/s00417-022-05670-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 03/01/2022] [Accepted: 04/08/2022] [Indexed: 11/24/2022] Open
Abstract
PURPOSE Iris incarceration is a complication of glaucoma filtering surgery that often requires surgery. We describe a technique for reduction of incarcerated iris at the slit lamp, dubbed rotational extraction of incarcerated iris (REII). A retrospective analysis of visual function and intraocular pressure (IOP) was done in patients treated with REII after nonpenetrating deep sclerectomy. METHODS We retrospectively evaluated a cohort of patients who received REII for iris incarceration after nonpenetrating deep sclerectomy for glaucoma. IOP (applanation) and visual acuity (VA) were measured day-of, and 1, 3, 6, and 12 months post-REII. Adverse events were recorded. Kaplan-Meier survival analysis was done with definitions of IOP control at 15, 18, and 21 mmHg. RESULTS Forty-one eyes of 41 patients were treated with REII. Median time to iris incarceration from glaucoma surgery was 50 days (range 1-1906). Mean pre-REII IOP ± SD was 33.7 ± 14.1 mmHg, which reduced to 11.5 ± 6.1 mmHg day-of. LogMAR VA was 0.72 ± 0.8 log units at baseline and was unchanged at 12 months (P = 0.53). Survival analysis demonstrated varying efficacy depending on the definition of success. 79.0 to 92.2% of eyes achieved IOP control immediately after REII, 39.5 to 71.1% at 1 month, 26.3 to 52.6% at 3 months, 21.1 to 44.3% at 6 months, and 10.5 to 38.0% at 12 months. Nearly half (47.4%) of eyes required a tube shunt by 12 months. CONCLUSION REII may be a safe, minimally invasive slit lamp procedure that can reduce incarcerated iris and delay more invasive intervention for 3-6 months in most eyes.
Collapse
Affiliation(s)
- Grant Slagle
- HCA Healthcare/USF Morsani College of Medicine GME/Regional Medical Center Bayonet Point, 14000 Fivay Rd, Hudson, FL, 34667, USA.
| | - Jeffrey Griffin
- WESMDPA Glaucoma Service, Baptist Medical Center, 311 Camden St, Ste 306, San Antonio, TX, 78215, USA
| | - William E Sponsel
- WESMDPA Glaucoma Service, Baptist Medical Center, 311 Camden St, Ste 306, San Antonio, TX, 78215, USA.,Department of Vision Sciences, University of the Incarnate Word, 7615 Kennedy Hill Dr, San Antonio, TX, 78235, USA
| |
Collapse
|
34
|
Kader MA, Dabke SB, Shukla AG, Reddy V, Abdul Khadar SM, Maheshwari D, Ramakrishnan R. Pars plana Aurolab aqueous drainage implantation for refractory glaucoma: Outcome of a new modified technique. Indian J Ophthalmol 2022; 70:839-845. [PMID: 35225526 PMCID: PMC9114538 DOI: 10.4103/ijo.ijo_1791_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
PURPOSE To report the outcomes of pars plana insertion of Aurolab aqueous drainage implant (AADI) in adults with refractory glaucoma by the novel technique of making scleral tunnel instead of patch graft to cover the tube to prevent its migration. METHODS A retrospective study was done between April 2016 and April 2018 on patients with ≥12 months of follow-up. The main outcome measure was a surgical failure at 12 months. The failure was defined as intraocular pressure (IOP) >18 mmHg or IOP ≤5 mmHg on two consecutive follow-up visits after 3 months, reoperation for glaucoma, loss of light perception vision, or implant explantation. Alternate definitions of failure including IOP >21 and IOP >15 mmHg were also considered. RESULTS : The study included 32 eyes of 32 patients. The mean age was 46.2 ± 17.5 years. The most common etiology is traumatic glaucoma (12 eyes, 37.5%). The mean preoperative IOP and anti-glaucoma medications were 43.3 ± 10.3 and 3.4 ± 0.5 mmHg, respectively; both the parameters at the final follow-up were reduced to 15.2 ± 8.1 and 1.6 ± 0.5 mmHg. The Kaplan-Meier survival estimates demonstrated that the cumulative probability of failure was 15.6% (95% CI; 6.8-33.5%) at 3 months, 18.7% (95% CI; 8.9-37.0%) at 6 months, and 25.0% (95% CI; 13.4-43.8%) at 12 months. CONCLUSION Pars plana AADI implantation with a newer modification technique is a useful procedure in reducing IOP and the number of anti-glaucoma medications in the eyes with refractory glaucoma. The visual acuity may be stabilized with the concurrent treatment of posterior segment pathology.
Collapse
Affiliation(s)
- Mohideen A Kader
- Glaucoma Services, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India
| | - Shylesh B Dabke
- Glaucoma Services, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India
| | - Aakriti G Shukla
- Wills Eye Hospital, Glaucoma Research Center, Philadelphia, PA, USA
| | - Venugopal Reddy
- Retina Services, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India
| | - Syed M Abdul Khadar
- Retina Services, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India
| | - Devendra Maheshwari
- Glaucoma Services, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India
| | - Rengappa Ramakrishnan
- Glaucoma Services, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India
| |
Collapse
|
35
|
Gambini G, Carlà MM, Giannuzzi F, Caporossi T, De Vico U, Savastano A, Baldascino A, Rizzo C, Kilian R, Caporossi A, Rizzo S. PreserFlo® MicroShunt: An Overview of This Minimally Invasive Device for Open-Angle Glaucoma. Vision (Basel) 2022; 6:vision6010012. [PMID: 35225971 PMCID: PMC8883991 DOI: 10.3390/vision6010012] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Revised: 01/30/2022] [Accepted: 02/03/2022] [Indexed: 01/25/2023] Open
Abstract
For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.
Collapse
Affiliation(s)
- Gloria Gambini
- Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Rome, Italy; (T.C.); (U.D.V.); (A.S.); (A.B.); (A.C.); (S.R.)
- Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy
- Correspondence: (G.G.); (M.M.C.); (F.G.); Tel.: +39-3276530138 (M.M.C.)
| | - Matteo Mario Carlà
- Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Rome, Italy; (T.C.); (U.D.V.); (A.S.); (A.B.); (A.C.); (S.R.)
- Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy
- Correspondence: (G.G.); (M.M.C.); (F.G.); Tel.: +39-3276530138 (M.M.C.)
| | - Federico Giannuzzi
- Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Rome, Italy; (T.C.); (U.D.V.); (A.S.); (A.B.); (A.C.); (S.R.)
- Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy
- Correspondence: (G.G.); (M.M.C.); (F.G.); Tel.: +39-3276530138 (M.M.C.)
| | - Tomaso Caporossi
- Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Rome, Italy; (T.C.); (U.D.V.); (A.S.); (A.B.); (A.C.); (S.R.)
- Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy
| | - Umberto De Vico
- Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Rome, Italy; (T.C.); (U.D.V.); (A.S.); (A.B.); (A.C.); (S.R.)
- Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy
| | - Alfonso Savastano
- Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Rome, Italy; (T.C.); (U.D.V.); (A.S.); (A.B.); (A.C.); (S.R.)
- Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy
| | - Antonio Baldascino
- Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Rome, Italy; (T.C.); (U.D.V.); (A.S.); (A.B.); (A.C.); (S.R.)
- Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy
| | - Clara Rizzo
- Ophthalmology, Department of Surgical, Medical and Molecular Pathology and Critical Care Medicine, University of Pisa, 56126 Pisa, Italy;
| | - Raphael Kilian
- Ophthalmology Unit, University of Verona, 37134 Verona, Italy;
| | - Aldo Caporossi
- Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Rome, Italy; (T.C.); (U.D.V.); (A.S.); (A.B.); (A.C.); (S.R.)
- Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy
| | - Stanislao Rizzo
- Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Rome, Italy; (T.C.); (U.D.V.); (A.S.); (A.B.); (A.C.); (S.R.)
- Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy
| |
Collapse
|
36
|
Silva N, Bollemeijer JG, Ferreira A, Menéres MJ, Lemij H. Donor scleral graft vs pericardial graft vs scleral flap in tube drainage covering: advantages and disadvantages. EXPERT REVIEW OF OPHTHALMOLOGY 2022. [DOI: 10.1080/17469899.2022.2026217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Nisa Silva
- Ophthalmology Department, Centro Hospitalar Universitário Do Porto, Porto, Portugal
| | | | - André Ferreira
- Ophthalmology Department, Centro Hospitalar Universitário Do Porto, Porto, Portugal
- Unit of Anatomy, Department of Biomedicine, Faculty of Medicine of the University of Porto, Porto, Portugal
| | - Maria João Menéres
- Ophthalmology Department, Centro Hospitalar Universitário Do Porto, Porto, Portugal
- Instituto de Ciências Biomédicas Abel Salazar, Universidade Do Porto, Porto, Portugal
| | - Hans Lemij
- Ophthalmology Department, Rotterdam Eye Hospital, Rotterdam Netherlands
| |
Collapse
|
37
|
Dawson EF, Culpepper BE, Bolch CA, Nguyen PT, Meyer AM, Rodgers CD, Wilson MK, Smith RJ, Rosenberg NC, Blake CR, Sherwood MB. Comparison of Outcomes Following Glaucoma Drainage Tube Surgery Between Primary and Secondary Glaucomas, and Between Phakic and Pseudophakic eyes. Asia Pac J Ophthalmol (Phila) 2021; 10:553-563. [PMID: 34839343 PMCID: PMC8673852 DOI: 10.1097/apo.0000000000000452] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 09/19/2021] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To report outcomes of glaucoma drainage device (GDD) surgery based on primary or secondary glaucoma diagnosis and lens status. DESIGN Single-center, retrospective, consecutive cohort study. METHODS University of Florida patients aged 18 to 93 years who underwent nonvalved GDD surgery between 1996 and 2015 with a minimum of 1-year follow-up were examined. Of the 186 eyes of 186 patients enrolled, 108 had a primary glaucoma and 78 a secondary glaucoma diagnosis. Excluding 13 aphakic patients, 57 eyes were phakic and 116 pseudophakic. Mean intraocular pressure (IOP), mean number of medications, visual acuity (VA), surgical complications, and failure (IOP ≥18 mm Hg, IOP <6 mm Hg, reoperation for glaucoma, or loss of light perception) were the main outcome measures. RESULTS No significant difference was noted in mean IOP and mean medication use (12.8 ± 4.5 and 13.0 ± 6.6 mm Hg on 2.0 ± 1.2 and 1.5 ± 1.1 medication classes, respectively), mean VA (1.08 ± 0.98 and 0.94 ± 0.89, respectively), failure, or numbers of complications and reoperations (P > 0.05) between eyes with primary and secondary glaucomas at up to 5 years postoperatively. Comparison of phakic and pseudophakic eyes showed a statistically significant higher success rate for the pseudophakic patient group at the ≥18 mm Hg upper limit and <6 mm Hg lower limit (P = 0.01), and significantly fewer eyes required reoperation to lower IOP (6.9% vs 23%). CONCLUSIONS GDD surgery appears equally effective for secondary glaucomas as for primary glaucomas, and has a better outcome for pseudophakic eyes than phakic eyes.
Collapse
Affiliation(s)
- Emily F Dawson
- Department of Ophthalmology, University of Florida, Gainesville, FL, US
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Elhusseiny AM, Yannuzzi NA, Khodeiry MM, Lee RK, Smiddy WE. Cost-analysis of Surgical Intraocular Pressure Management in Glaucoma. J Glaucoma 2021; 30:947-951. [PMID: 34506357 DOI: 10.1097/ijg.0000000000001938] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Accepted: 08/23/2021] [Indexed: 02/03/2023]
Abstract
PRCIS The multiplicity of treatment options for lowering intraocular pressure (IOP) is both a blessing and a challenge. Some attention to cost-analysis might assist in choosing an optimal therapy, especially in a cost-constrained, international setting. PURPOSE The aim of this study was to quantify and to analyze the relative cost of various glaucoma surgical procedures and selective laser trabeculoplasty surgery per mm Hg IOP reduction ($/mm Hg) since standard cost-utility methods are not well suited to the study of glaucoma which characteristically only claims visual acuity in its end stages. METHODS Published glaucoma treatment studies were reviewed to quantitate the reduction of mean IOP and glaucoma medications for a given treatment modality. A US perspective was adopted, using Medicare allowable costs were used to calculate a newly introduced parameter-cost per mm Hg IOP reduction-at 1 year postoperatively. RESULTS The cost per mm Hg IOP reduction after 1 year of treatment ranged from $190/mm Hg for trabeculectomy to $1376/mm Hg for iStent. For reference, the cost of selective later trabeculoplasty surgery was $121/mm Hg. After the first year, cost/mm Hg ranged from $12 to $61/mm Hg. CONCLUSIONS Conventional glaucoma surgeries and selective laser trabeculoplasty surgery were the most cost-efficient surgical methods to lower IOP compared with the various minimally invasive glaucoma surgeries options. They may be more appropriate management when cost is an important issue.
Collapse
Affiliation(s)
- Abdelrahman M Elhusseiny
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL
- Department of Ophthalmology, Harvey and Bernice Jones Eye Institute, University of Arkansas for Medical Sciences, Little Rock, AR
| | - Nicolas A Yannuzzi
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL
| | - Mohamed M Khodeiry
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL
| | - Richard K Lee
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL
| | - William E Smiddy
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL
| |
Collapse
|
39
|
Wagner FM, Schuster AK, Munder A, Muehl M, Chronopoulos P, Pfeiffer N, Hoffmann EM. Comparison of subconjunctival microinvasive glaucoma surgery and trabeculectomy. Acta Ophthalmol 2021; 100:e1120-e1126. [PMID: 34626093 DOI: 10.1111/aos.15042] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 09/11/2021] [Accepted: 09/22/2021] [Indexed: 12/29/2022]
Abstract
PURPOSE To assess surgical success and the post-operative development of intraocular pressure between XEN45® gelstent, Preserflo® MicroShunt and trabeculectomy with mitomycin C. METHODS Data from 105 eyes from 105 patients of matched cases with refractory open-angle glaucoma, who underwent surgery between January 2019, and August 2020, were evaluated. Patients underwent either stand-alone XEN gelstent insertion with Mitomycin C, stand-alone Preserflo with Mitomycin C or trabeculectomy with Mitomycin C. The primary outcome was the proportion of complete surgical success at 6 months post-operatively (i.e. intraocular pressure between 5mmHg and 18mmHg, no revision surgery, no loss of light perception and no post-operative pharmaceutical antiglaucomatous treatment). The reduction of intraocular pressure after 6 months, the classes of antiglaucomatous medication used post-operatively, best-corrected visual acuity, spherical refractive errors and astigmatism were assessed as secondary outcomes. RESULTS We included 35 eyes in each group. After 6-month follow-up, complete success was 73.5% [95%-CI: 57.9%-89.2%] in the trabeculectomy group, 51.4% [95%-CI: 34.0%-68.8%] in the XEN group and 74.2% [95%-CI: 57.9%-90.5%] in the Preserflo group (p = 0.08). Regarding secondary outcomes, the reduction of intraocular pressure was 12.1 ± 7.9 mmHg in the trabeculectomy group and was thereby 5.8 [95%-CI: 2.2-9.6] mmHg greater compared with the XEN group (p < 0.001) and 4.8 [95%-CI: 0.9-8.7] mmHg higher than the Preserflo group (p = 0.01). CONCLUSIONS No statistically significant differences were found between trabeculectomy, XEN45® gelstent implantation and Preserflo® MicroShunt implantation regarding surgical success after 6 months. Yet reduction in intraocular pressure was significantly higher in the trabeculectomy group. However, all three interventions resulted in sufficiently low post-operative intraocular pressure and may therefore be considered individually for glaucoma treatment.
Collapse
Affiliation(s)
- Felix M. Wagner
- Department of Ophthalmology University Medical Center of the Johannes Gutenberg‐University Mainz Mainz Germany
| | - Alexander K. Schuster
- Department of Ophthalmology University Medical Center of the Johannes Gutenberg‐University Mainz Mainz Germany
| | - Annika Munder
- Department of Ophthalmology University Medical Center of the Johannes Gutenberg‐University Mainz Mainz Germany
| | - Marius Muehl
- Department of Ophthalmology University Medical Center of the Johannes Gutenberg‐University Mainz Mainz Germany
| | | | - Norbert Pfeiffer
- Department of Ophthalmology University Medical Center of the Johannes Gutenberg‐University Mainz Mainz Germany
| | - Esther M. Hoffmann
- Department of Ophthalmology University Medical Center of the Johannes Gutenberg‐University Mainz Mainz Germany
| |
Collapse
|
40
|
Fili S, Vastardis I, Perdikakis G, Kohlhaas M. Transscleral cyclophotocoagulation with MicroPulse® laser versus cyclophotocoagulation with continuous diode laser in patients with open-angle glaucoma. Int Ophthalmol 2021; 42:525-539. [PMID: 34596834 DOI: 10.1007/s10792-021-02023-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 09/22/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE To present the efficacy and safety of surgical treatment of moderate to advanced stage of open-angle glaucoma using the surgical method of transscleral cyclophotocoagulation with MicroPulse® laser (Iridex, Silicon Valley, California, USA) and to compare these results with those of continuous transscleral cyclophotocoagulation with diode laser. METHODS In a prospective observational clinical study 22 patients (30 eyes) with moderate and advanced open-angle glaucoma underwent transscleral cyclophotocoagulation. 15 eyes were treated with transscleral cyclophotocoagulation with MicroPulse® laser with 2500 mW (group A) and 15 eyes with continuous diode laser 810 nm and power between 2000 and 2300 mW (group B). The follow-up period of the study was 12 months. RESULTS A reduction of the intraocular pressure > 30% was achieved in 53.3% of the group A and in 60% of the group B during the follow-up period of 12 months. A statistically significant decrease of the number of antiglaucoma agents was observed in group A. One eye (6.6%) of group A underwent additional antiglaucoma procedures to achieve target intraocular pressure. The corresponding percentage is 40% in group B. The postoperative inflammatory response was significantly more limited in group A compared to group B. CONCLUSIONS The transscleral cyclophotocoagulation with MicroPulse® diode laser with 2500 mW achieves a similar decrease of the intraocular pressure as cyclophotocoagulation with continuous diode laser for the first postoperative months, but more satisfactory reduction of the number of eye drops as well as more limited postoperative inflammatory response.
Collapse
Affiliation(s)
- Sofia Fili
- Clinic of Ophthalmology, St. Johannes Hospital in Dortmund, Johannesstraße 9-13, 44137, Dortmund, Germany.
| | - Iraklis Vastardis
- Clinic of Ophthalmology, St. Johannes Hospital in Dortmund, Johannesstraße 9-13, 44137, Dortmund, Germany
| | - Georgios Perdikakis
- Clinic of Ophthalmology, St. Johannes Hospital in Dortmund, Johannesstraße 9-13, 44137, Dortmund, Germany
| | - Markus Kohlhaas
- Clinic of Ophthalmology, St. Johannes Hospital in Dortmund, Johannesstraße 9-13, 44137, Dortmund, Germany
| |
Collapse
|
41
|
Zhang H, Yan X, Li F, Ma L, Geng Y, Jiao K, Tang G. Microcatheter-Assisted Trabeculotomy Combined With Deep Sclerectomy and Trabeculectomy in Young to Middle-Aged Adults With Advanced Primary Open-Angle Glaucoma: 1-Year Result. Front Med (Lausanne) 2021; 8:712332. [PMID: 34540866 PMCID: PMC8446351 DOI: 10.3389/fmed.2021.712332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 08/02/2021] [Indexed: 12/02/2022] Open
Abstract
Objective: We aimed to evaluate the safety and clinical efficacy of ab externo microcatheter-assisted trabeculotomy combined with deep sclerectomy and trabeculectomy (MATT-DS-Trab) in the surgical management of advanced primary open-angle glaucoma (POAG). Methods: According to the inclusion criteria, we retrospectively collected and analyzed 37 POAG cases in advanced stage who received MATT-DS-Trab. The intraocular pressure (IOP), best corrected visual acuity (BCVA), use of anti-glaucoma drugs, shape of the filtering bleb, size of the scleral lake, complications, and the surgical success rate were recorded. Results: The mean IOP was 37.50 ± 8.11 mmHg before the operation, while it depleted to 10.08 ± 2.01 and 11.43 ± 2.07 mmHg at 1 week and 12 months after the operation, respectively (both P < 0.001 compared to preoperative IOP). From none to two kinds of anti-glaucoma drugs were used 12 months after surgery on the patients, which were significantly reduced compared with that preoperatively (P < 0.001). An L-type filtering bleb was the main form at all time points after the operation. At 12 months following surgery, an F-type filtering bleb accounted for 5.41% and no E-type filtering bleb was recorded. The length and height of the scleral lake shrunk with time, but there was no statistical significance (P > 0.05). Also, there was no correlation between the size of the scleral pool and the IOP (P > 0.05). At 12 months after the operation, the complete success rates were 94.59, 83.78, and 72.97% according to standards A (≤18 mmHg), B (≤15 mmHg), and C (≤12 mmHg), respectively. Intraoperative complications were mainly anterior chamber hemorrhage, and no complications related to the filtration bleb were observed after the operation. Conclusion: Based on multichannel mechanisms, MATT-DS-Trab is able to effectively reduce IOP in advanced POAG patients, with few serious complications and a high success rate.
Collapse
Affiliation(s)
- Hengli Zhang
- Department of Ophthalmology, Shijiazhuang People's Hospital, Shijiazhuang, China
| | - Xiaowei Yan
- Department of Ophthalmology, Shijiazhuang People's Hospital, Shijiazhuang, China
| | - Fan Li
- Department of Ophthalmology, Shijiazhuang People's Hospital, Shijiazhuang, China
| | - Lihua Ma
- Department of Ophthalmology, Shijiazhuang People's Hospital, Shijiazhuang, China
| | - Yulei Geng
- Department of Ophthalmology, Shijiazhuang People's Hospital, Shijiazhuang, China
| | - Kexin Jiao
- Department of Ophthalmology, Shijiazhuang People's Hospital, Shijiazhuang, China
| | - Guangxian Tang
- Department of Ophthalmology, Shijiazhuang People's Hospital, Shijiazhuang, China
| |
Collapse
|
42
|
Khodeiry MM, Sheheitli H, Sayed MS, Persad PJ, Feuer WJ, Lee RK. Treatment Outcomes of Slow Coagulation Transscleral Cyclophotocoagulation In Pseudophakic Patients with Medically Uncontrolled Glaucoma. Am J Ophthalmol 2021; 229:90-99. [PMID: 33852906 DOI: 10.1016/j.ajo.2021.04.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/23/2021] [Accepted: 04/01/2021] [Indexed: 11/19/2022]
Abstract
PURPOSE Reporting treatment outcomes of slow coagulation transscleral cyclophotocoagulation (TSCPC) as an initial surgical intervention in pseudophakic patients with glaucoma. DESIGN Retrospective case series. METHODS This single academic center study reviewed 74 pseudophakic patients who had a diagnosis of glaucoma and no previous glaucoma surgeries (mean age 82.6 ± 12.5 years; mean follow-up 18.7 ± 9.1 months). The intervention used was slow coagulation continuous wave TSCPC (1250-mW power and 4-second duration). The primary outcome measure was surgical success defined as an intraocular pressure (IOP) of 6-21 mm Hg with a ≥20% reduction from baseline, no reoperation for glaucoma, and no loss of light-perception vision. Secondary outcome measures included glaucoma medication use, visual acuity (VA), and complications. RESULTS IOP decreased from 27.5 ± 9.8 mm Hg preoperatively to 16.1 ± 6.3 mm Hg postoperatively (P < .001). The preoperative number of glaucoma medications was 4.1 ± 0.9 and 3.1 ± 1.3 post-TSCPC (P < .001). The cumulative probabilities of success at 1 and 2 years were 60.6 % and 58.5%, respectively. When patients were divided into 2 groups based on their baseline IOP being >21 mm Hg (high group) or ≤21 mm Hg (low group), success rates at 2 years were 64.9% and 45.5%, respectively (P = .144). The mean logarithm of the minimum angle of resolution VA changed from 0.70 ± 0.64 to 1.04 ± 0.87 at the last follow-up visit (P = .01). No serious complications were observed and most of the complications were mild and transient. CONCLUSIONS Slow coagulation TSCPC has good efficiency, especially in patients with baseline IOP >21 mm Hg, and safety profile as an initial surgical intervention in pseudophakic patients with glaucoma.
Collapse
Affiliation(s)
- Mohamed M Khodeiry
- Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Huda Sheheitli
- Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Mohamed S Sayed
- Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Patrice J Persad
- Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - William J Feuer
- Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Richard K Lee
- Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida, USA.
| |
Collapse
|
43
|
Vanner EA, Sun CQ, McSoley MJ, Persad PJ, Feuer WJ, Lum F, Kelly SP, Parrish RK, Chang TC, Gedde SJ. Tube Versus Trabeculectomy IRIS Ⓡ Registry 1-Year Composite Outcome Analysis with Comparisons to the Randomized Controlled Trial. Am J Ophthalmol 2021; 227:87-99. [PMID: 33657420 DOI: 10.1016/j.ajo.2021.02.023] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 01/19/2021] [Accepted: 02/16/2021] [Indexed: 11/21/2022]
Abstract
PURPOSE This study compared 1-year results for the composite treatment outcome from the Tube Versus Trabeculectomy (TVT) randomized controlled trial (RCT) to those from an IRISⓇ (Intelligent Research In Sight) Registry cohort of analogous eyes. DESIGN Retrospective clinical study with comparison to an RCT. METHODS Subjects' eyes in the IRIS Registry received either a glaucoma drainage implant (tube) or underwent trabeculectomy after a previous trabeculectomy and/or cataract extraction and had data for 1-year follow-up analyses. OUTCOME Eyes were classified as failing if they had hypotony (intraocular pressure (IOP) ≤5 mm Hg) or inadequate IOP control (IOP >21 mm Hg or not reduced at least 20% below baseline) on 2 consecutive follow-up visits after 3 months, a reoperation for glaucoma, or no light perception vision and as successful otherwise. Failure risk was compared by treatment, demographic, and clinical variables and was compared to analogous failure risks from the TVT RCT. RESULTS The TVT IRIS Registry cohort included 419 eyes, 236 tube eyes (56.3%) and 183 trabeculectomy eyes (43.7%). In this cohort, there was no significant failure risk difference (12.3% for tube eyes and 16.4% for trabeculectomy eyes, P = 0.231). Comparing the studies, there was a significantly greater risk of failure in the TVT IRIS Registry tube eyes than in the TVT RCT tube eyes (3.8%; P <.001). Reasons for treatment failure included reoperations for glaucoma (none in the TVT RCT at 1 year). CONCLUSIONS Our results were different from those in the TVT RCT. Possible reasons include non-Baerveldt tubes, greater severity among tube eyes, and practice patterns that reflect real-world data, which are different than those in RCTs.
Collapse
Affiliation(s)
| | - Catherine Q Sun
- Bascom Palmer Eye Institute, Miami, Florida, USA; University of California San Francisco, San Francisco, California, USA
| | - Matthew J McSoley
- Bascom Palmer Eye Institute, Miami, Florida, USA; University of Miami Miller School of Medicine, Miami, Florida, USA
| | | | | | - Flora Lum
- American Academy of Ophthalmology, San Francisco, California
| | - Scott P Kelly
- American Academy of Ophthalmology, San Francisco, California
| | | | - Ta C Chang
- Bascom Palmer Eye Institute, Miami, Florida, USA
| | | |
Collapse
|
44
|
Schlenker MB, Ong JA, Wu P, Jinapriya D, Zack B, Dorey MW, Harasymowycz PJ, Ahmed IIK. Surgeon Experience as a Risk Factor for Short-Term Failure for Ab Interno Gelatin Microstent: A Canadian Multicenter Propensity-Matched Study. Ophthalmol Glaucoma 2021; 5:67-76. [PMID: 34089949 DOI: 10.1016/j.ogla.2021.05.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 05/16/2021] [Accepted: 05/26/2021] [Indexed: 11/18/2022]
Abstract
PURPOSE To compare the efficacy and safety of early versus later ab interno gelatin microstent placement with mitomycin C. DESIGN Canada-wide, multicenter, retrospective propensity score-matched cohort study. PARTICIPANTS Two hundred seventy eyes (135 early cases and 135 later cases) with no prior incisional surgery. METHODS Surgeons' first 20 patients (early cases group), from 6 glaucoma surgeons across 4 Canadian sites, were matched 1:1 to patients with the closest propensity score from the later (21+) patients (later cases group). MAIN OUTCOME MEASURES Primary outcome was hazard ratio (HR) of failure of the early versus later cases groups, with failure defined as IOP of less than 6 mmHg with more than 2 lines of vision loss or more than 17 mmHg with no medications (complete success) on 2 consecutive visits despite in-clinic maneuvers (including needling) more than 1 month after surgery. Secondary outcomes were HRs for failure, defined as IOP outside the range of 6 to 14 mmHg and 6 to 21 mmHg with and without allowing for medications (qualified success), interventions, complications, and reoperations. RESULTS Hazard ratio of failure for early versus later cases groups was 1.38 (95% confidence interval [CI], 0.97-1.96) for the IOP range of 6 to 17 mmHg, 1.29 (95% CI, 0.90-1.84) for 6 to 14 mmHg, and 1.48 (95% CI, 1.03-2.13) for 6 to 21 mmHg without medication and 0.95 (95% CI, 0.55-1.64), 0.95 (95% CI, 0.61-1.48), and 0.95 (95% CI, 0.52-1.75) for the same IOP ranges allowing for medications. Needling rates were 43.0% (early cases group) and 41.5% (later cases group). Complication rates after 1 month occurred in 9.6% (early cases group) and 11.1% (later cases group; P = 0.69). Reoperation rates were 14.8% (early cases group) and 8.1% (later cases group; P = 0.08). CONCLUSIONS There is some evidence for improved success in the later cases group. Similar needling rates, similar complication rates, and a slightly higher reoperation rate were found for the early cases group. The results suggest that this procedure can be adopted by existing surgeons with current training regimens, although they may see an improvement in their success outcomes over time.
Collapse
Affiliation(s)
- Matthew B Schlenker
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada; Prism Eye Institute, Mississauga, Canada
| | - Jeb Alden Ong
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada; Prism Eye Institute, Mississauga, Canada
| | - Pearson Wu
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada; Prism Eye Institute, Mississauga, Canada
| | - Delan Jinapriya
- Department of Ophthalmology, Queen's University, Kingston, Canada
| | - Barend Zack
- Department of Ophthalmology, University of British Columbia, Vancouver, Canada
| | - Michael W Dorey
- Department of Ophthalmology, University of Alberta, Edmonton, Canada
| | | | - Iqbal Ike K Ahmed
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada; Prism Eye Institute, Mississauga, Canada.
| |
Collapse
|
45
|
Jagannathan J, George R, Shantha B, Vijaya L. Outcome of repeat trabeculectomy with mitomycin C in isolation or combined with phacoemulsification. Indian J Ophthalmol 2021; 69:94-98. [PMID: 33323585 PMCID: PMC7926097 DOI: 10.4103/ijo.ijo_144_20] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Purpose: To evaluate the effectiveness of repeat trabeculectomy with Mitomycin C (MMC) in isolation or combined with phacoemulsification, and to identify risk factors for failure over 1 year. Methods: Retrospective review of 113 eyes of 113 patients (49 primary open angle, 27 primary angle closure, 37 secondary glaucoma) who underwent repeat trabeculectomy with MMC (isolated trabeculectomy 75 and phacotrabeculectomy 38). The primary outcome measure was intraocular pressure (IOP) at 1 year follow-up. Three IOP criteria were chosen to measure success A) IOP ≤21 mmHg and ≥20% reduction from baseline. B) IOP ≤17 mmHg and ≥20% reduction from baseline. C) IOP ≤14 mmHg. Results: Mean IOP decreased from 24.5 ± 8.8 mmHg to 16.4 ± 7.6 mmHg 1 year after repeat trabeculectomy. The mean number of medications reduced from 2.9 ± 1.0 to 0.6 ± 1.0. Complete success with trabeculectomy versus phacotrabeculectomy for criterion A was 60% vs 55.3%, criterion B 54.7% vs 50.0% and criterion C 40.0% vs 28.9%. IOP ≤14 mmHg was more likely with trabeculectomy than phacotrabeculectomy (P = 0.047). On regression analysis, duration between surgeries ≤4 years (P = 0.018) and secondary glaucoma (P = 0.046) were identified as risk factors for surgical failure with criterion A. Younger age (P = 0.042), fornix based flap (P = 0.058), and phacotrabeculectomy (P = 0.042) for criterion C. Conclusion: Repeat trabeculectomy with MMC is successful at lowering IOP and decreasing number of antiglaucoma medications. Low IOP levels are less likely with phacotrabeculectomy.
Collapse
Affiliation(s)
| | - Ronnie George
- Sri Jadhavbai Nathmal Singhvi Glaucoma Services, Chennai, Tamil Nadu, India
| | - B Shantha
- Sri Jadhavbai Nathmal Singhvi Glaucoma Services, Chennai, Tamil Nadu, India
| | - L Vijaya
- Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India
| |
Collapse
|
46
|
Huth A, Viestenz A. [Micropulse cyclophotocoagulation lowers the intraocular pressure: half year results]. Ophthalmologe 2021; 119:19-24. [PMID: 33931788 DOI: 10.1007/s00347-021-01391-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/31/2021] [Accepted: 04/07/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND Cyclophotocoagulation (CPC) is a simple noninvasive and quickly available procedure for lowering intraocular pressure but due to its dreaded potential for complications it continues to play an outsider role in surgical treatment planning. The Micropulse-CPC promises to be a more tissue-friendly and less painful procedure and thus a lower rate of side effects. METHOD Retrospective evaluation of all patients who were treated with the Micropulse-CPC laser at the measurement times 1 day preoperatively, 2 days postoperatively, after 3 months and 6 months. RESULTS Between 2018 and 2019 a total of 63 eyes in 46 patients were treated. The mean intraocular pressure in the total collective was 20.6 mm Hg before surgery and decreased to 13.5 mm Hg 2 days after surgery, 16.2 mm Hg after 3 months and 14.6 mm Hg after 6 months (p < 0.002). An average of 3.2 hypotensive substances were used preoperatively, 2.4 substances 2 days postoperatively, 2.6 substances after 3 months and 2.8 after 6 months (p < 0.001). The visual acuity (VA) before surgery was 0.59 logMAR, 2 days postoperatively VA was 0.60, after 3 months 0.59 and after 6 months VA was 0.5 (statistically not significant). A complication (subconjunctival bleeding) occurred intraoperatively and the postoperative complication rate was 0%. CONCLUSION Treatment with a Micropulse-CPC laser offers a gentle way of reducing pressure in a timely manner. The use of the Micropulse-CPC is advocated as a first surgical option as well as for patients with good visual acuity.
Collapse
Affiliation(s)
- Andrea Huth
- Martin-Luther-Universitat Halle-Wittenberg, Halle (Saale), Deutschland.
| | | |
Collapse
|
47
|
The Tube Versus Trabeculectomy IRIS® Registry Study: Cohort Selection and Follow-up and Comparisons to the Randomized Controlled Trial. Am J Ophthalmol 2021; 224:43-52. [PMID: 33306999 DOI: 10.1016/j.ajo.2020.11.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 11/19/2020] [Accepted: 11/27/2020] [Indexed: 11/21/2022]
Abstract
PURPOSE To assess the feasibility of replicating a randomized controlled trial (RCT) with a cohort of eyes, from IRIS® Registry data, analogous to the Tube Versus Trabeculectomy (TVT) RCT cohort and compare characteristics and follow-up. DESIGN Comparison of RCT and IRIS Registry cohorts and follow-up. METHODS We identified a cohort of IRIS Registry eyes (2013-2017) that received either a glaucoma drainage implant (tube) or trabeculectomy after a previous trabeculectomy and/or cataract extraction; extracted clinical and demographic characteristics for baseline surgery and follow-up visits through 1 year; and compared treatment groups in the IRIS Registry cohort and this cohort to the TVT RCT cohort. RESULTS The IRIS Registry cohort included 419 eyes: 183 (43.7%) trabeculectomy; 236 (56.3%) tube. There were significant differences between treatment groups, including race (White: trabeculectomy 61.8%, tube 44.9%; Black: trabeculectomy 20.8%, tube 35.6%; P = .003) and the percentage of follow-up visits completed (trabeculectomy 88.4%, tube 83.8%, P = .004). There were also significant differences between the TVT IRIS Registry cohort and the TVT RCT cohort in the percentage of follow-up visits completed (IRIS Registry 85.6%, RCT 96.1%, P < .001) and in the probability of having a 1-year follow-up visit (IRIS Registry 81.4%, RCT 89.2%, P = .011). CONCLUSION The TVT IRIS Registry cohort had several significant treatment group differences at baseline, whereas there had been none in the TVT RCT cohort. Follow-up in the TVT IRIS Registry cohort was inferior to that of the TVT RCT. Some data needed to refine the selection of eyes for the cohort were not available in the IRIS Registry.
Collapse
|
48
|
Wagdy F, Mokbel TH, Elsorogy H, Alnagdy A, Elfattah DA, Elhesy AEA. An Ex-Press implant versus trabeculectomy in a fibrotic bleb with late failure after previous trabeculectomy. Int J Ophthalmol 2021; 14:383-387. [PMID: 33747813 DOI: 10.18240/ijo.2021.03.08] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Accepted: 12/08/2020] [Indexed: 11/23/2022] Open
Abstract
AIM To compare the outcome of an Ex-Press implant and subscleral trabeculectomy (SST) in the management of glaucoma after previous trabeculectomy on a fibrotic bleb. METHODS This randomized prospective study included 28 eyes from 28 patients (age range: 42-55y) with primary open angle glaucoma (POAG) presented with elevated intraocular pressure (IOP) with fibrotic bleb despite previous SST for more than 4mo. The eyes enrolled in the study were divided into two groups: group I (subjected to Ex-Press implant surgery) and group II [subjected to SST with mitomycin C (MMC)]. The follow-up continued one year after surgery to evaluate IOP, visual acuity (VA), visual field (VF), and postoperative complications. RESULTS A significant decrease in IOP was found in both groups with a higher reduction in Ex-Press implant surgery with the mean IOP of 14.50 mm Hg (P=0.001), while the SST group recorded the mean IOP of 16.50 mm Hg (P=0.001) after one year. However, the difference between the two groups in terms of the decrease in IOP was insignificant. Fewer postoperative complications were recorded in the Ex-Press implant surgery and more cases requiring further anti-glaucomatous medications were seen in the SST group. Both groups showed stability in terms of VA and VF. CONCLUSION Ex-Press implant surgery and SST with MMC are two surgical alternatives for controlling IOP in late failure that occurs more than 4mo after previous SST with a fibrotic bleb. However, Ex-Press shunt is a safer surgery with fewer complications.
Collapse
Affiliation(s)
- Faried Wagdy
- Menofia University Hospital, Menofia University, Menofia 32511, Egypt
| | - Tharwat H Mokbel
- Mansoura Ophthalmic Center, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt
| | - Hisham Elsorogy
- Mansoura Ophthalmic Center, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt
| | - Ahmed Alnagdy
- Mansoura Ophthalmic Center, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt
| | - Dina Abd Elfattah
- Mansoura Ophthalmic Center, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt
| | - Abd-Elmonem A Elhesy
- Mansoura Ophthalmic Center, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt
| |
Collapse
|
49
|
Efficacy and Safety of the Susanna Glaucoma Drainage Device After 1 Year of Follow-up. J Glaucoma 2021; 30:e231-e236. [PMID: 33534511 DOI: 10.1097/ijg.0000000000001802] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 01/20/2021] [Indexed: 11/26/2022]
Abstract
PRECIS This study found a rate of failure of 13.6% of the new Susanna Glaucoma Drainage Device (SGDD) after 1 year of follow-up. Severe complications occurred in 1 patient (4.5%). PURPOSE The purpose of this study was to determine the success and complications rates of the SGDD implant in refractory glaucoma. PATIENTS AND METHODS This is a retrospective study. Medical records from all consecutive refractory glaucoma patients (failed trabeculectomies with the use of adjunctive mitomycin) followed in a private clinical practice were included in the study. All patients had undergone SGDD implant surgery from September 2016 to July 2019 were included. All surgeries were done by the same surgeon (R.S.). Primary outcome was surgical failure, defined as intraocular pressure (IOP) >18 mm Hg and/or <20% IOP reduction from baseline, IOP<5 mm Hg, reoperation for glaucoma, need of implant removal or loss of light perception vision. Secondary outcomes included mean IOP, use of supplemental medical therapy, and complications. RESULTS In all, 22 eyes were analyzed. Mean patient age was 63±15 years (range: 27 to 87 y). Mean IOP decreased from 23±7 to 11±8 mm Hg (P<0.001, paired t test) at an average of 18±9 months after the tube implant. The mean SD number of glaucoma medications was reduced from 3.3±1 to 1.5±1.2 at the last postoperative visit (P<0.01, paired t test). No early postoperative complications occurred. There was 1 case of late persistent hypotony in a patient with previous endocyclophotocoagulation that was solved with tube ligature with silk 8-0. Failure because of high IOP occurred in 2 cases. There was no extrusion or erosion of the tube and the plate. CONCLUSION The SGDD presented a 13.6% failure rate (86.4% success rate) with very few complications, being an efficient and safe alternative for refractory glaucoma.
Collapse
|
50
|
Siggel R, Schroedl F, Dietlein T, Koch KR, Platzl C, Kaser-Eichberger A, Cursiefen C, Heindl LM. Absence of lymphatic vessels in non-functioning bleb capsules of glaucoma drainage devices. Histol Histopathol 2021; 35:1521-1531. [PMID: 33382078 DOI: 10.14670/hh-18-300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
PURPOSE To evaluate the presence and appearance of blood and lymphatic vessels in non-functioning bleb capsules of glaucoma drainage devices (GDD). MATERIALS AND METHODS Non-functioning (n=14) GDD-bleb capsules of 12 patients were analyzed by immunohistochemistry for blood vessels (CD31, vascular endothelium), lymphatic vessels (lymphatic vessel endothelial hyaluronan receptor-1 [LYVE-1] and podoplanin) and macrophages (CD68). RESULTS CD31+++ blood vessels and CD68+ macrophages were detected in the outer layer of all specimens. LYVE-1 immunoreactivity was registered in single non-endothelial cells in 8 out of 14 (57%) bleb capsule specimens. Podoplanin-immunoreactivity was detected in all cases, located in cells and profiles of the collagen tissue network of the outer and/or the inner capsule layer. However, a colocalization of LYVE-1 and podoplanin as evidence for lymphatic vessels was not detected. CONCLUSIONS We demonstrate the presence of blood-vessels but absence of lymphatic vessels in non-functioning bleb capsules after GDD-implantation. While the absence of lymphatic vessels might indicate a possible reason for drainage device failure, this needs to be confirmed in upcoming studies, including animal experiments.
Collapse
Affiliation(s)
- Robert Siggel
- Department of Ophthalmology, University of Cologne, Cologne, Germany.,Department of Ophthalmology, HELIOS University Hospital Wuppertal, University Witten/Herdecke, Germany.
| | - Falk Schroedl
- Institute of Anatomy and Cell Biology, Paracelsus Medical University, Salzburg, Austria
| | - Thomas Dietlein
- Department of Ophthalmology, University of Cologne, Cologne, Germany
| | - Konrad R Koch
- Department of Ophthalmology, University of Cologne, Cologne, Germany
| | - Christian Platzl
- Institute of Anatomy and Cell Biology, Paracelsus Medical University, Salzburg, Austria
| | | | - Claus Cursiefen
- Department of Ophthalmology, University of Cologne, Cologne, Germany.,Center for Molecular Medicine Cologne (CMMK), University of Cologne, Cologne, Germany
| | - Ludwig M Heindl
- Department of Ophthalmology, University of Cologne, Cologne, Germany
| |
Collapse
|