1
|
Almasri KG, Pichi F. Uveitis-Glaucoma-Hyphema Syndrome Secondary to Implantable Collamer Lens. Ocul Immunol Inflamm 2024:1-4. [PMID: 38652606 DOI: 10.1080/09273948.2024.2342386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 04/08/2024] [Indexed: 04/25/2024]
Abstract
Purpose: To report the first case of uveitis-glaucoma-hyphema (UGH) syndrome post implantable collamer lens (ICL).Methods: Case reportResults: A 41-year-old female presented to our clinic complaining of bilateral eye pain and redness for two weeks. Her past medical history was significant for ICL, in both eyes and multiple sclerosis controlled with treatment. She had a long-standing history of bilateral recurrent uveitis and glaucoma. Ultrasound biomicroscopy revealed several sulcus cysts displacing the ICLs haptic into the ciliary body, leading to iris abrasion and uveitis-glaucoma-hyphema syndrome.Conclusion: We present the first published case worldwide about UGH syndrome secondary to ICL. This is an unusual complication, and measures can be taken to avoid it. This provides evidence of the importance of postoperative follow-up by the surgeon and appropriate work-up when such cases are suspected.
Collapse
Affiliation(s)
| | - Francesco Pichi
- Eye Institute, Cleveland Clinic Abu Dhabi, Abu Dhabi, UAE
- Cleveland Clinic Lerner College of Medicine, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
2
|
Chan NSW, Lim JS, Mohanram LS, Chee SP. Ultrasound biomicroscopy in the management of complex cataract and intraocular lens: A review. Clin Exp Ophthalmol 2024; 52:186-206. [PMID: 38214059 DOI: 10.1111/ceo.14321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/29/2023] [Accepted: 11/05/2023] [Indexed: 01/13/2024]
Abstract
Ultrasound biomicroscopy (UBM) is an invaluable investigation for imaging anterior segment structures. Although it is operator-dependent and time consuming, unlike optical-based imaging techniques, it is able to image structures posterior to the iris, such as the zonules, ciliary body and part of the pars plana. It is especially useful in advanced cataracts, traumatic cataracts, subluxed lenses, posterior polar cataracts, and congenital and developmental anomalies affecting the anterior segment. It provides diagnostic information in eyes with complex cataracts or intraocular lens (IOL)-related pathology, and aids in surgical planning in order to minimise complications. In this review, we describe the UBM features of various lenticular pathologies and demonstrate its application in the diagnosis and surgical management of lens and IOL-related pathologies.
Collapse
Affiliation(s)
- Nicole S W Chan
- Department of Ophthalmology, National University Hospital, Singapore, Singapore
| | - Jane S Lim
- Singapore National Eye Centre, Singapore, Singapore
- Singapore Eye Research Institute, Singapore, Singapore
| | | | - Soon-Phaik Chee
- Singapore National Eye Centre, Singapore, Singapore
- Singapore Eye Research Institute, Singapore, Singapore
- Duke-NUS Graduate Medical School, Singapore, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| |
Collapse
|
3
|
Gong D, Deng S, Dang K, Yan Z, Wang J. Causes and management strategies for elevated intraocular pressure after implantable collamer lens implantation. Front Med (Lausanne) 2024; 11:1351272. [PMID: 38384405 PMCID: PMC10879591 DOI: 10.3389/fmed.2024.1351272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 01/25/2024] [Indexed: 02/23/2024] Open
Abstract
With the widespread application of Implantable Collamer Lens (ICL) implantation surgery in the field of myopia correction, a comprehensive understanding of its potential complications, especially those related to intraocular pressure (IOP), becomes crucial. This article systematically reviews various complications that may lead to IOP elevation after ICL surgery. Firstly, common complications after ICL surgery, including residual viscoelastic, steroid response, and excessive vault of the ICL, are detailed, emphasizing their potential impact on intraocular pressure. Regarding residual viscoelastic, we delve into its direct relationship with postoperative elevated IOP and possible preventive measures. For steroid response, we stress the importance of timely adjustment of steroid therapy and monitoring intraocular pressure. Additionally, excessive vault of the ICL is considered a significant potential issue, and we elaborate on its mechanism and possible management methods. In further discussion, we focus on relatively rare complications such as Toxic Anterior Segment Syndrome (TASS), Urrets-Zavalia Syndrome (UZS), Pigment Dispersion Syndrome (PDS), and malignant glaucoma. For these relatively rare complications, this review thoroughly explores their potential mechanisms, emphasizes the importance of prevention, and provides guidance for early diagnosis and treatment. This is a comprehensible review that aims to offer eye care professionals a comprehensive understanding and effective management guidance for complications of elevated IOP after ICL surgery, ultimately providing optimal care for patients' visual health.
Collapse
Affiliation(s)
- Di Gong
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| | - Simin Deng
- The 2nd Clinical Medical College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Kuanrong Dang
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| | - Zonghui Yan
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| | - Jiantao Wang
- Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen, Guangdong, China
| |
Collapse
|
4
|
Ramesh PV, Parthasarathi S, Azad A, Devadas AK, Ragolu T, Ramesh SV, Ramesh MK, Rajasekaran R. Managing Pigment Dispersion Glaucoma Postbilateral ICL Implantation in High Myopia: A Case Report on the Crucial Role of Gonioscopy in Correcting a Misdiagnosis. J Curr Glaucoma Pract 2024; 18:31-36. [PMID: 38585164 PMCID: PMC10997960 DOI: 10.5005/jp-journals-10078-1433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 03/16/2024] [Indexed: 04/09/2024] Open
Abstract
Secondary open-angle glaucoma (SOAG) is a rare yet consequential complication following implantable collamer lens (ICL), also known as a phakic intraocular lens insertion, particularly in high myopia patients. This case report emphasizes the importance of recognizing SOAG and details the diagnostic complexities, reevaluation procedures, and successful long-term management of a 24-year-old bilateral high myopia (-7.00 D) patient who initially received an erroneous diagnosis of secondary angle-closure glaucoma (SACG) after ICL insertion at an external medical facility. Persistent visual issues prompted the patient to seek a second opinion, leading to a comprehensive reevaluation that eventually unveiled pigment dispersion syndrome (PDS) as the underlying cause, subsequently resulting in SOAG. This case not only highlights the diagnostic challenges but also elucidates the re-evaluation process and effective 5-year management strategies employed to restore the patient's visual health and quality of life. How to cite this article Ramesh PV, Parthasarathi S, Azad A, et al. Managing Pigment Dispersion Glaucoma Postbilateral ICL Implantation in High Myopia: A Case Report on the Crucial Role of Gonioscopy in Correcting a Misdiagnosis. J Curr Glaucoma Pract 2024;18(1):31-36.
Collapse
Affiliation(s)
- Prasanna V Ramesh
- Department of Glaucoma and Research, Mahathma Eye Hospital Private Limited, Tiruchirappalli, Tamil Nadu, India
| | - Sathyan Parthasarathi
- Department of General Ophthalmology and Glaucoma Services, Sathyan Eye Care Hospital and Coimbatore Glaucoma Foundation, Coimbatore, Tamil Nadu, India
| | - Ashik Azad
- Department of Optometry and Visual Science, Mahathma Eye Hospital Private Limited, Tiruchirappalli, Tamil Nadu, India
| | - Aji K Devadas
- Department of Optometry and Visual Science, Mahathma Eye Hospital Private Limited, Tiruchirappalli, Tamil Nadu, India
| | - Tejaswi Ragolu
- Department of Cataract and Biometry, Mahathma Eye Hospital Private Limited, Tiruchirappalli, Tamil Nadu, India
| | - Shruthy V Ramesh
- Department of Cataract and Refractive Surgery, Mahathma Eye Hospital Private Limited, Tiruchirappalli, Tamil Nadu, India
| | - Meena K Ramesh
- Department of Cataract and Refractive Surgery, Mahathma Eye Hospital Private Limited, Tiruchirappalli, Tamil Nadu, India
| | - Ramesh Rajasekaran
- Department of Pediatric Ophthalmology and Strabismus, Mahathma Eye Hospital Private Limited, Tiruchirappalli, Tamil Nadu, India
| |
Collapse
|
5
|
Katsimpris A, Kumarasamy M. Bilateral Late-Onset Pigment Dispersion Syndrome following Implantable Collamer Lens Surgery: A Case Report. Case Rep Ophthalmol 2024; 15:399-405. [PMID: 38682039 PMCID: PMC11052560 DOI: 10.1159/000538547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 03/23/2024] [Indexed: 05/01/2024] Open
Abstract
Introduction We report a case of bilateral pigment dispersion syndrome after 13 years of uncomplicated implantable collamer lens (ICL) surgery. Case Presentation A 53-year-old woman was referred from her optometrist to our glaucoma clinic due to early superonasal visual field loss in both eyes. She was asymptomatic with no changes in visual acuity and had undergone bilateral ICL implantation 13 years ago to correct her high myopia. Clinical examination revealed pigment deposition on the corneal endothelium, iris transillumination defects, and iris vaulting at the areas of contact with the ICL. Gonioscopy showed open angles with significant pigmentation of the trabecular meshwork. The diagnosis of pigment dispersion syndrome secondary to ICL implantation was made, and subsequent follow-up visits demonstrated normal intraocular pressure IOP and stable visual fields. Conclusion Pigmentary dispersion syndrome can occur several years after ICL implantation. This case report emphasizes the need for long-term follow-up and monitoring after ICL surgery.
Collapse
|
6
|
Martínez-Plaza E, López-de la Rosa A, Ossa-Calderon C, Blázquez-Arauzo F, López-Miguel A, Maldonado MJ. Assessment of the iridocorneal angle pigmentation and structures after the implantation of EVO+ Visian Implantable Collamer Lens. Int Ophthalmol 2023; 43:4711-4718. [PMID: 37697080 DOI: 10.1007/s10792-023-02871-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 08/26/2023] [Indexed: 09/13/2023]
Abstract
PURPOSE To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures. METHODS Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients' information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test. RESULTS Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25). CONCLUSIONS The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain
| | - Alberto López-de la Rosa
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, Universidad de Valladolid, Valladolid, Spain
| | - Carolina Ossa-Calderon
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Francisco Blázquez-Arauzo
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain.
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain.
- Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, Universidad de Valladolid, Valladolid, Spain.
| | - Miguel J Maldonado
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain
- Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, Universidad de Valladolid, Valladolid, Spain
| |
Collapse
|
7
|
Fang B, Zhu QJ, Yang H, Fan LC. Vault predicting after implantable collamer lens implantation using random forest network based on different features in ultrasound biomicroscopy images. Int J Ophthalmol 2023; 16:1561-1567. [PMID: 37854385 PMCID: PMC10559038 DOI: 10.18240/ijo.2023.10.01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 08/02/2023] [Indexed: 10/20/2023] Open
Abstract
AIM To analyze ultrasound biomicroscopy (UBM) images using random forest network to find new features to make predictions about vault after implantable collamer lens (ICL) implantation. METHODS A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient's preoperative parameters as well as the vault of the ICL after implantation. The vault was set as the prediction target, and the input elements were mainly ciliary sulcus shape parameters, which included 6 angular parameters, 2 area parameters, and 2 parameters, distance between ciliary sulci, and anterior chamber height. A random forest regression model was applied to predict the vault, with the number of base estimators (n_estimators) of 2000, the maximum tree depth (max_depth) of 17, the number of tree features (max_features) of Auto, and the random state (random_state) of 40.0. RESULTS Among the parameters selected in this study, the distance between ciliary sulci had a greater importance proportion, reaching 52% before parameter optimization is performed, and other features had less influence, with an importance proportion of about 5%. The importance of the distance between the ciliary sulci increased to 53% after parameter optimization, and the importance of angle 3 and area 1 increased to 5% and 8% respectively, while the importance of the other parameters remained unchanged, and the distance between the ciliary sulci was considered the most important feature. Other features, although they accounted for a relatively small proportion, also had an impact on the vault prediction. After parameter optimization, the best prediction results were obtained, with a predicted mean value of 763.688 µm and an actual mean value of 776.9304 µm. The R2 was 0.4456 and the root mean square error was 201.5166. CONCLUSION A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection.
Collapse
Affiliation(s)
- Bin Fang
- School of Mechanical and Electrical Engineering, Soochow University, Suzhou 215100, Jiangsu Province, China
| | - Qiu-Jian Zhu
- Lixiang Eye Hospital of Soochow University, Suzhou 215021 Jiangsu Province, China
| | - Hui Yang
- School of Mechanical and Electrical Engineering, Soochow University, Suzhou 215100, Jiangsu Province, China
| | - Li-Cheng Fan
- School of Mechanical and Electrical Engineering, Soochow University, Suzhou 215100, Jiangsu Province, China
| |
Collapse
|
8
|
Naujokaitis T, Auffarth GU, Łabuz G, Kessler LJ, Khoramnia R. Diagnostic Techniques to Increase the Safety of Phakic Intraocular Lenses. Diagnostics (Basel) 2023; 13:2503. [PMID: 37568866 PMCID: PMC10417808 DOI: 10.3390/diagnostics13152503] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/25/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023] Open
Abstract
Preoperative and postoperative diagnostics play an important role in ensuring the safety of patients with phakic intraocular lenses (pIOLs). The risk of endothelial cell loss can be addressed by regularly measuring the endothelial cell density using specular microscopy and considering the endothelial cell loss rate and the endothelial reserve in accordance with the patient's age when deciding whether to explant a pIOL. The anterior chamber morphometrics, including the anterior chamber depth and the distance between the pIOL and the endothelium, measured using Scheimpflug tomography and anterior segment optical coherence tomography (AS-OCT), can help to assess the risk of the endothelial cell loss. In patients undergoing posterior chamber pIOL implantation, accurate prediction of the vault and its postoperative measurements using AS-OCT or Scheimpflug tomography are important when assessing the risk of anterior subcapsular cataract and secondary glaucoma. Novel approaches based on ultrasound biomicroscopy and AS-OCT have been proposed to increase the vault prediction accuracy and to identify eyes in which prediction errors are more likely. Careful patient selection and regular postoperative follow-up visits can reduce the complication risk and enable early intervention if a complication occurs.
Collapse
Affiliation(s)
| | | | | | | | - Ramin Khoramnia
- Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany
| |
Collapse
|
9
|
Tan X, Liu W, Chang Y, Wu W, Yang L, Liu J. Analysis of Inter-Eye Vault Differences After Implantable Collamer Lens (V4c) Implantation. Int J Gen Med 2023; 16:2451-2459. [PMID: 37346811 PMCID: PMC10281286 DOI: 10.2147/ijgm.s384858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 06/12/2023] [Indexed: 06/23/2023] Open
Abstract
Purpose The safety and stability of implantable collamer lens (ICL) implantation are closely related to the vault. We aimed to assess clinical data from patients with similar anterior segment anatomy who received ICL of the same model placed in the same position and analyze common range and factors affecting the vault inter-eye difference. Patients and Methods A prospective study was performed, including 162 eyes of 81 patients with a bilateral ICL (V4c) implantation. Subjects were evaluated before the surgery and 1 day, 1 week, and 1 month postoperatively, and they were divided into 4 groups based on the ICL size. Bivariate correlation and multiple linear regression (stepwise) analyzed associations between vault inter-eye differences and horizontal sulcus-to-sulcus diameter, anterior chamber depth, lens thickness, ICL size, spherical equivalent, and vault. Results One month after surgery, mean vault inter-eye differences were 74.59 ± 55.59 µm. Nearly 70% of patients presented with vault inter-eye differences lower than 100 µm. The second eye vault variance of 69% was attributed to the first eye vault. Vault inter-eye differences were positively correlated with ICL spherical equivalent (regression equation: vault inter-eye differences (μm) = 139.415 + 6.295 × ICL spherical equivalent). Vaults after ICL implantation were similar in fellow eyes, with some considerable differences. The 95% confidence interval of the vault inter-eye difference was -34.4 ~ 183.6 μm. Conclusion In eyes with similar anterior segment anatomy, there is a 95% probability that the vault will vary from -34.4 μm to -183.6 μm when a similar ICL is implanted. These results can help surgeons to select an appropriate ICL size to achieve an ideal vault. The smaller the spherical equivalent, the larger the difference between the two vaults, which provides a reference for size in moderate myopia. ICL spherical equivalent affects and predicts vault inter-eye differences after ICL implantation.
Collapse
Affiliation(s)
- Xin Tan
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Wenjie Liu
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Ying Chang
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Wanmin Wu
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Lichun Yang
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| | - Jiewei Liu
- Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People’s Republic of China
| |
Collapse
|
10
|
Li X, Wang M, Dong W, Cai J. Anterior segment structure changes caused by different luminance light after implantable collamer lens surgery. BMC Ophthalmol 2023; 23:281. [PMID: 37328783 DOI: 10.1186/s12886-023-03014-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Accepted: 06/03/2023] [Indexed: 06/18/2023] Open
Abstract
BACKGROUNDS To investigate the changes of anterior eye segment with implantable collamer lens (ICL) under mesopic and photopic conditions. METHOD Forty-seven eyes of myopic patients who underwent ICL V4c implantation were included. Three months after surgery, the pupil diameter (PD), dynamic vault, ACD (distance from the posterior corneal surface to the anterior lens surface), ACD-ICL (distance from the posterior corneal surface to the anterior ICL surface), and anterior chamber angle parameters were measured using the anterior segment optical coherence tomography (AS-OCT, Carl Zeiss AG, Germany) under completely mesopic (0 lx) and photopic (5290 lx) lighting conditions. RESULTS Compared with mesopic conditions, a significant decreased vault was detected in photopic conditions (486.7 ± 186.1 μm versus 643.5 ± 191.2 μm, p < 0.001), while the ACD-ICL increased significantly (2.54 ± 0.24 mm versus 2.37 ± 0.23 mm, p < 0.001). The pupil was smaller in photopic condition (2.66 ± 0.23 mm versus 5.62 ± 0.55 mm, p < 0.001). ACD didn't change(3.32 ± 0.24 mm versus 3.31 ± 0.22 mm, p = 0.079). The change of the vault was positively related to the changes of the PD (r2 = 0.301, p = 0.04). There were no statistical difference between the change of vault and the change of ACD-ICL (158.0 ± 58.1 μm versus 165.9 ± 65.3 μm, p = 0.320). CONCLUSION When exposed to high intensity light after ICL surgery, the pupil constricted, vault decreased, ACA widened and ACD-ICL increased. All these changes were caused by the change of iris not the crystalline lens.
Collapse
Affiliation(s)
- Xia Li
- Department of Ophthalmology, Shanghai Aier Eye Hospital, Shanghai, China.
| | - Min Wang
- Department of Ophthalmology, Shanghai Aier Eye Hospital, Shanghai, China
| | - Weiwen Dong
- Department of Auxiliary Examination, Shanghai Aier Eye Hospital, Shanghai, China
| | - Jinfeng Cai
- Department of Ophthalmology, Shanghai Aier Eye Hospital, Shanghai, China.
| |
Collapse
|
11
|
Zhu QJ, Xing XY, Zhu MH, Ma L, Yuan Y, Song E. Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study. BMC Ophthalmol 2022; 22:463. [PMID: 36451125 PMCID: PMC9714062 DOI: 10.1186/s12886-022-02698-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 11/21/2022] [Indexed: 12/05/2022] Open
Abstract
BACKGROUND To verify the accuracy and stability of the prediction formula based on the ciliary sulcus diameter and lens thickness and to analyse factors influencing the prediction results. METHODS In total, 925 eyes from 506 subjects were enrolled in this prospective study between July 1, 2020, and June 30, 2021. Subjects were divided into four seasons, each spanning three months. The target vault was set to be between 300 μm and 700 μm according the prediction formula. The actual vault was measured one month postoperatively. The Bland-Altman test, 95% confidence intervals (95% CI) and 95% limits of agreement (95% LoA) were used to evaluate the agreement between the predicted vault and the actual vault. Eyes with absolute prediction errors greater than 300 μm were further analysed. RESULTS The mean predicted vaults for the four seasons were 503 ± 99, 494 ± 96, 481 ± 92 and 502 ± 93 μm, while the mean actual vaults were 531 ± 189, 491 ± 179, 464 ± 179 and 529 ± 162 μm, respectively. The predicted and actual vaults of the overall subjects were 493 ± 95 and 500 ± 180 μm, respectively. Of the 925 eyes, 861 eyes (93.08%), 42 eyes (4.54%), and 22 eyes (2.38%) showed a normal vault, high vault, and low vault, respectively. Bland-Altman plots showed that the mean difference between the actual vault and predicted vault overall (± 95% LoA) was 6.43 ± 176.2 μm (-339 to 352 μm). Three UBM features may lead to large prediction errors (more than 300 μm): wide iris-ciliary angle (ICA), iris concavity and anteriorly positioned ciliary body. CONCLUSIONS This study demonstrated the accuracy and stability of the prediction formula through the validation of a large sample size and a long time span. Wide ICA, iris concavity and anteriorly positioned ciliary body may have an effect on vault.
Collapse
Affiliation(s)
- Qiu-Jian Zhu
- grid.452666.50000 0004 1762 8363Department of Ophthalmology, The Second Affiliated Hospital of Soochow University, Suzhou, China ,grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | | | - Man-Hui Zhu
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - Lie Ma
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - You Yuan
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| | - E. Song
- grid.263761.70000 0001 0198 0694Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Suzhou, China
| |
Collapse
|
12
|
Zhu QJ, Zhu WJ, Chen WJ, Ma L, Yuan Y. A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study. BMC Ophthalmol 2022; 22:307. [PMID: 35842598 PMCID: PMC9287952 DOI: 10.1186/s12886-022-02535-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 07/13/2022] [Indexed: 11/15/2022] Open
Abstract
Background To establish and verify the accuracy and reliability of a sulcus-to-sulcus diameter (STS) prediction model. Methods In this retrospective study, the prediction formula was established with the data from 1466 eyes from 733 subjects from July 2020 to April 2021 and verified with the data from 278 eyes from 139 subjects between May 2021 and June 2021. Each subject was measured with a Pentacam, IOLMaster 700, OPD-Scan III, and ultrasound biomicroscope. The prediction formulas were established with multiple linear regression, and intergroup correlation coefficients (ICCs) and Bland–Altman tests were used to assess the agreement between the predicted and actual STS (actual STS was measured by UBM). Results The explanatory variables relevant to the horizontal STS (STSH) were the Pentacam white-to-white diameter (WTWP; standardized partial regression coefficient [β] = 0.330; p < 0.001), the flat K value (β = -0.211; p < 0.001), and the anterior corneal diameter (ACD) (β = 0.178; p < 0.001). The corresponding multiple regression equation was : STSH (mm) = 8.061 + 0.510 × WTWP − 0.090 × Flat K value + 0.430 × ACD. The explanatory variables relevant to the vertical STS (STSV) were the WTWP (β = 0.435; p < 0.001), the steep K value (β = -0.271; p < 0.001), and the ACD (β = 0.187; p < 0.001). The corresponding multiple regression equation was : STSV (mm) = 8.540 + 0.492 × WTWP − 0.075 × Steep K value + 0.329 × ACD. The bias of the predicted to the actual STSH was − 0.021, with 95% limits of agreement (95% LoA) from − 0.499 to 0.457. The bias of the predicted to the actual STSV was 0.057, with 95% LoA from − 0.462 to 0.575. The ICC was 0.883 between the predicted and actual STSH and 0.859 between the predicted and actual STSV. Conclusions The Pentacam-measured WTW, the K value and the ACD are important for predicting the STS diameter. The prediction model has good accuracy and reliability. Trial registration Not applicable.
Collapse
Affiliation(s)
- Qiu-Jian Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China
| | - Wei-Jian Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China
| | - Wen-Jing Chen
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China
| | - Lie Ma
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China
| | - You Yuan
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, 215021, Jiangsu, Suzhou, China.
| |
Collapse
|
13
|
Teplovodskaya VV, Sobolev NP, Morina NA, Zhuravlev AS, Sudakova EP. [Correction of ametropia with posterior chamber phakic intraocular lens]. Vestn Oftalmol 2022; 138:64-70. [PMID: 35234423 DOI: 10.17116/oftalma202213801164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Posterior chamber phakic intraocular lens (PIOL) implantation is a widely accepted and performed refractive surgery for correction of moderate and high myopia used when corneal laser ablation procedures are not suitable. This paper analyzes literature data to reveal the advantages and limitations of the technology.
Collapse
Affiliation(s)
- V V Teplovodskaya
- S.N. Fedorov National Medical Research Center «MNTK «Eye Microsurgery», Moscow, Russia
| | - N P Sobolev
- S.N. Fedorov National Medical Research Center «MNTK «Eye Microsurgery», Moscow, Russia
| | - N A Morina
- S.N. Fedorov National Medical Research Center «MNTK «Eye Microsurgery», Moscow, Russia
| | - A S Zhuravlev
- S.N. Fedorov National Medical Research Center «MNTK «Eye Microsurgery», Moscow, Russia
| | - E P Sudakova
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| |
Collapse
|
14
|
Reinstein DZ, Vida RS, Archer TJ. Visual Outcomes, Footplate Position and Vault Achieved with the Visian Implantable Collamer Lens for Myopic Astigmatism. Clin Ophthalmol 2021; 15:4485-4497. [PMID: 34848942 PMCID: PMC8612663 DOI: 10.2147/opth.s330879] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 11/01/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose Report the outcomes of the implantable collamer lens (ICL) in myopic astigmatism using very high-frequency (VHF) digital ultrasound sizing. Methods Analysis of 42 consecutive ICL procedures using EVO and EVO+ (Visian V4c) lenses (STAAR Surgical) was done. ICL size was chosen using the ultrasound-based Kojima Formula with Insight 100 VHF digital ultrasound (VHFDU). Standard visual outcomes analysis was performed using 3-month data, also including contrast sensitivity, refractive and corneal vector analysis, and ECC. Postoperative lens position was evaluated using VHF digital ultrasound. Results Attempted SEQ was −10.83±3.39D (−4.40 to −16.98D). Cylinder was −1.46±1.15D (0.00 to −4.25D). One-year follow-up was available in 86% of the eyes and 3 months in 96%. Postoperative UDVA was 20/20 or better in 89% of the eyes, relative to 71% preoperatively. Postoperative SEQ refraction was ±0.50 D in 74% and ±1.00 D in 98% of the eyes. There was a gain of one line of CDVA in 43% of the eyes, 2 or more lines in 10% of the eyes, while there was a one line loss in 7% and no eyes lost 2 or more lines. The vector mean for the corneal SIA was 0.24 D Ax 100. Contrast sensitivity showed a statistically significant increase with a mean of 0.14 log units at 6, 12, and 18 cycles per degree (P<0.01). The mean change in ECC was −153±353 cells/mm2. Lens vault was 506±233 µm (114–924 µm). Footplate insertion was in zonular position in 48.3%, ciliary body in 49.2%, and sulcus in 2.5% of locations. Conclusion ICL implantation resulted in high safety and efficacy but with an implantation vault range that ideally would be improved upon. VHF digital ultrasound of the lens footplate and posterior anatomical relations may provide essential information for evaluating postoperative vault outliers.
Collapse
Affiliation(s)
- Dan Z Reinstein
- London Vision Clinic, London, UK.,Columbia University Medical Center, New York, NY, USA.,Sorbonne Université, Paris, France.,Biomedical Science Research Institute, Ulster University, Coleraine, UK
| | | | | |
Collapse
|
15
|
Coskunseven E, Kayhan B, Jankov Ii MR. Tuck-and-pull technique for posterior chamber phakic intraocular lens explantation. Indian J Ophthalmol 2021; 69:3740-3742. [PMID: 34827034 PMCID: PMC8837325 DOI: 10.4103/ijo.ijo_652_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
The tuck-and-pull technique was developed for practical and safe explantations of posterior chamber phakic intraocular lenses (PCPIOLs). In this technique, after the creation of a side port, viscoelastic (or OVD [ophthalmic viscosurgical device]) is initially injected behind the PCPIOL to widen the space between PCPIOL and the crystalline lens. The old incisions can be used after recent implantations rendering the enlargement of the main incision unnecessary. After additional OVD over and under the PCPIOL, the haptic is tucked by a chopper and pulled through the main incision with a single maneuver. The haptic is grasped by two suture forceps and explanted with a "hand-to-hand" maneuver. The tuck-and-pull technique provided high protection of the corneal endothelium, crystalline lens, anterior chamber structures, and the PCPIOL itself. This technique is a practical, easy, and safe approach for explantations of all PCPIOL types, whatever the reason for its explantation may be.
Collapse
Affiliation(s)
- Efekan Coskunseven
- Department of Refractive Surgery, Dunyagoz Etiler Hospital; Department of Health Services, Faculty of Health Sciences, Istanbul Rumeli University, Istanbul, Turkey
| | - Belma Kayhan
- Department of Refractive Surgery, Dunyagoz Etiler Hospital; Department of Ophthalmology, Sultan II. Abdulhamid Han Training and Research Hospital, University of Health Sciences, Istanbul, Turkey
| | - Mirko R Jankov Ii
- Department of Cataract and Refractive Surgery, LaserFocus-Centre for Eye Microsurgery, Belgrade, Serbia; IROC - Institute for Refractive and Ophthalmic Surgery, Zurich, Switzerland
| |
Collapse
|
16
|
Owaidhah O, Al-Ghadeer H. Bilateral Cataract Development and Pupillary Block Glaucoma Following Implantable Collamer Lens. J Curr Glaucoma Pract 2021; 15:91-95. [PMID: 34720499 PMCID: PMC8543747 DOI: 10.5005/jp-journals-10078-1309] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Aim and objective We report the first case of bilateral cataract formation and pupillary block glaucoma and high intraocular pressure (IOP) following implantable Collamer lens (ICL) implantation that resulted in advanced visual field loss. Background The patient who underwent bilateral ICL implantation can develop bilaterally elevated IOP and an anterior subcapsular cataract with altitudinal visual field defect. Case description A 38-year-old man with high myopia presented for routine follow-up status post bilateral phakic ICL placement. The visual acuity was reduced due to an anterior subcapsular cataract and elevated IOP in both eyes with advanced glaucomatous visual field defects. The patient was treated with topical glaucoma medications. The left eye underwent same-day phakic ICL explanation and cataract surgery to prevent further visual field loss. Conclusion Cataract and glaucoma are serious complications after phakic ICL implantation; therefore, regular postoperative monitoring may prevent advanced visual impairment. Clinical significance The use of a phakic intraocular lens for the correction of myopia may result in complications. As a measure is to reduce such complications, refractive surgeons preferred using phakic posterior chamber intraocular Collamer lens for the correction of myopia. How to cite this article Owaidhah O, Al-Ghadeer H. Bilateral Cataract Development and Pupillary Block Glaucoma Following Implantable Collamer Lens. J Curr Glaucoma Pract 2021;15(2):91–95.
Collapse
Affiliation(s)
- Ohoud Owaidhah
- Department of Glaucoma, King Khaled Eye Specialist Hospital, Riyadh, Kingdom of Saudi Arabia
| | - Huda Al-Ghadeer
- Department of Anterior Segment, King Khaled Eye Specialist Hospital, Riyadh, Kingdom of Saudi Arabia
| |
Collapse
|
17
|
Hu X, Wang P, Zhu C, Yuan Y, Liu M, Ke B. Transient reduction in the retinal microvascular network following implantation surgery of implantable collamer lens: An OCT angiography study. Mol Vis 2021; 27:466-479. [PMID: 34321861 PMCID: PMC8286798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Accepted: 07/15/2021] [Indexed: 11/04/2022] Open
Abstract
Purpose To evaluate changes in the retinal microvascular network after posterior chamber phakic implantable collamer lens (ICL) surgery using optical coherence tomography angiography (OCTA) in patients with high myopia. Methods Patients with high myopia who underwent ICL surgery were enrolled in this study. All patients underwent comprehensive ophthalmologic exams preoperatively and 1 week, 1 month, and 3 months postoperatively. The vascular densities (VDs) in the retina and the superficial and deep capillary plexuses of different annular and quadrantal areas were evaluated from OCTA images (Zeiss Cirrus 5000). Correlations between the variations in microvascular density and possible factors were further analyzed. Results The study comprised 32 eyes of 32 patients. The mean age of the patients was 26.91±7.610 years (15 men and 17 women). A statistically significant reduction in microvascular density in the retina and the superficial plexus was found 1 week and 1 month postoperatively (p<0.05, repeated-measures ANOVA). Further fractal analysis found that the VD of the outer ring declined statistically significantly (p<0.05). A statistically significant decrease was also found in the inferior nasal sector 1 week postoperatively, with an overall decrease in all four quadrants 1 month postoperatively. The microvascular density recovered toward the baseline level 3 months postoperatively. No correlations were observed between the variation in microvascular density and the spherical equivalent (SE), axial length (AL), intraocular pressure (IOP), amplitude of accommodation (AA), or contrast sensitivity. Conclusions Retinal microvascular density was decreased postoperatively and then recovered toward the baseline level after 3 months. ICL surgery may have a transient influence on the retinal microvascular network without affecting visual function.
Collapse
Affiliation(s)
- Xiaojun Hu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China,Shanghai Key Laboratory of Fundus Disease, Shanghai, China,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China,Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China,National Clinical Research Center for Eye Diseases, Shanghai, China
| | - Peng Wang
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China,Shanghai Key Laboratory of Fundus Disease, Shanghai, China,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
| | - Chengcheng Zhu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China,Shanghai Key Laboratory of Fundus Disease, Shanghai, China,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
| | - Ying Yuan
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China,Shanghai Key Laboratory of Fundus Disease, Shanghai, China,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
| | - Mingming Liu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China,Shanghai Key Laboratory of Fundus Disease, Shanghai, China,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
| | - Bilian Ke
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China,Shanghai Key Laboratory of Fundus Disease, Shanghai, China,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China,Shanghai Engineering Center for Precise Diagnosis and Treatment of Eye Diseases, Shanghai, China,National Clinical Research Center for Eye Diseases, Shanghai, China
| |
Collapse
|
18
|
Wei W, Yu X, Yang L, Xiong C, Zhang X. Diode laser transscleral cyclophotocoagulation causes intraocular collamer lens displacement in pseudophakic eye: a case report. BMC Ophthalmol 2021; 21:268. [PMID: 34187412 PMCID: PMC8244133 DOI: 10.1186/s12886-021-02026-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Accepted: 06/14/2021] [Indexed: 11/17/2022] Open
Abstract
Background With the rapid development of intraocular collamer lens (ICL) operation, it is foreseeable that we will encounter a large number of glaucoma patients with ICL implantation history. However, our current understanding of the treatment of glaucoma patients with ICL is limited. Hence we report a rare case of refractory glaucoma after intraocular collamer lens and intraocular lens implantation in a patient who underwent unsuccessful transscleral cyclophotocoagulation, which led to intraocular collamer lens displacement, angle closure and uncontrolled intraocular pressure. Case presentation A 39-year-old woman presented with intractably elevated intraocular pressure in the right eye. Since her intraocular collamer lens implantation surgery in 2017, her intraocular pressure had remained over 40 mmHg while using 3 types of anti-glaucoma medications. The patient had a history of phacoemulsification and posterior chamber phakic intraocular lens implantation for complicated cataracts secondary to uveitis in 2006. On gonioscope examination, there were signs of pigment dispersion, and the anterior chamber angle was open. Ultrasound biomicroscopy examination showed contact and rubbing between the intraocular collamer lens and posterior surface of the iris. And typical advanced glaucomatous optic neuropathy and visual field defects were observed. Transscleral cyclophotocoagulation was performed to control the intraocular pressure and prevent further visual field loss. However, the intraocular collamer lens was displaced after transscleral cyclophotocoagulation, which resulted in formation of a shallow anterior chamber 1 week later, angle closure and loss of intraocular pressure control 1 month later, even though the maximum dose of anti-glaucoma medication was used. Finally, an Ahmed glaucoma valve was successfully implanted in her anterior chamber, and the glaucoma was controlled, as observed at the 10-month follow-up. Conclusions Pigment dispersion is a common phenomenon after intraocular collamer lens implantation and may accelerate the progression of glaucoma. Transscleral cyclophotocoagulation should be carefully considered in glaucoma patients with elevated intraocular pressure after intraocular collamer lens implantation, given that transscleral cyclophotocoagulation may cause intraocular collamer lens displacement.
Collapse
Affiliation(s)
- Wei Wei
- Affiliated Eye Hospital of Nanchang University, Jiangxi Research Institute of Ophthalmology and Visual Science, Jiangxi Clinical Research Center of Ophthalmic Disease, Nanchang, Jiangxi, People's Republic of China
| | - Xueqing Yu
- Affiliated Eye Hospital of Nanchang University, Jiangxi Research Institute of Ophthalmology and Visual Science, Jiangxi Clinical Research Center of Ophthalmic Disease, Nanchang, Jiangxi, People's Republic of China
| | - Lu Yang
- Affiliated Eye Hospital of Nanchang University, Jiangxi Research Institute of Ophthalmology and Visual Science, Jiangxi Clinical Research Center of Ophthalmic Disease, Nanchang, Jiangxi, People's Republic of China
| | - Chan Xiong
- Affiliated Eye Hospital of Nanchang University, Jiangxi Research Institute of Ophthalmology and Visual Science, Jiangxi Clinical Research Center of Ophthalmic Disease, Nanchang, Jiangxi, People's Republic of China
| | - Xu Zhang
- Affiliated Eye Hospital of Nanchang University, Jiangxi Research Institute of Ophthalmology and Visual Science, Jiangxi Clinical Research Center of Ophthalmic Disease, Nanchang, Jiangxi, People's Republic of China.
| |
Collapse
|
19
|
Zhu QJ, Chen WJ, Zhu WJ, Xiao HX, Zhu MH, Ma L, Yuan Y, Song E. Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation. BMC Ophthalmol 2021; 21:199. [PMID: 33957891 PMCID: PMC8101126 DOI: 10.1186/s12886-021-01963-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 04/26/2021] [Indexed: 12/16/2022] Open
Abstract
Background To describe the very early vault changes in the first month after Implantable Collamer Lens (ICL) implantation and to evaluate the effect of preoperative biometric factors on vault. Methods Eighty-three eyes from eighty-three subjects with complete data who met follow-up requirements were recruited in this retrospective study between May 2019 and March 2020. We quantitatively assessed the postoperative vault at 2 h, 1 day, 1 week, and 1 month following implantation. Associations between the postoperative vault and age, ICL size, spherical equivalent (SE), axial length (AL), central corneal thickness (CCT), flat keratometry (K), steep K, mean K, anterior chamber depth (ACD), crystalline lens thickness (LT), white-to-white (WTW) diameter obtained by three devices, horizontal and vertical sulcus-to-sulcus (STS) diameter, bright and dark pupil sizes (BPS and DPS) and DPS-BPS were investigated using Spearman’s correlation analysis and stepwise multiple regression analysis. Results The mean vault values at 2 h, 1 day, 1 week, and 1 month after ICL implantation were 672.05 ± 30.72, 389.15 ± 28.33, 517.23 ± 30.76 and 530.12 ± 30.22 μm, respectively. Significant differences were found in the vault values at 2 h, 1 day and 1 week after the operation. The ICL size (β = 0.942; p < 0.001), followed by horizontal STS (β = -0.517; p < 0.001), crystalline LT (β = -0.376; p < 0.001) and vertical STS (β = -0.257; p = 0.017), significantly influenced the vault at 1 month after the operation. The multiple regression equation was expressed as follows: central vault (µm) = -1369.05 + 657.121 × ICL size- 287.408 × horizontal STS − 432.497 × crystalline LT − 137.33 × vertical STS (adjusted R2 = 0.643). Conclusions After ICL implantation, the vault decreased and then increased, but it did not return to the vault value 2 h after surgery. The ICL size, horizontal and vertical STS and crystalline LT are key factors for predicting postoperative vaulting. Supplementary Information The online version contains supplementary material available at 10.1186/s12886-021-01963-x.
Collapse
Affiliation(s)
- Qiu-Jian Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Wen-Jing Chen
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Wei-Jian Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Hai-Xiang Xiao
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Man-Hui Zhu
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - Lie Ma
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| | - You Yuan
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China.
| | - E Song
- Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China
| |
Collapse
|
20
|
The Genetic and Endoplasmic Reticulum-Mediated Molecular Mechanisms of Primary Open-Angle Glaucoma. Int J Mol Sci 2020; 21:ijms21114171. [PMID: 32545285 PMCID: PMC7312987 DOI: 10.3390/ijms21114171] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/04/2020] [Accepted: 06/09/2020] [Indexed: 12/14/2022] Open
Abstract
Glaucoma is a heterogenous, chronic, progressive group of eye diseases, which results in irreversible loss of vision. There are several types of glaucoma, whereas the primary open-angle glaucoma (POAG) constitutes the most common type of glaucoma, accounting for three-quarters of all glaucoma cases. The pathological mechanisms leading to POAG pathogenesis are multifactorial and still poorly understood, but it is commonly known that significantly elevated intraocular pressure (IOP) plays a crucial role in POAG pathogenesis. Besides, genetic predisposition and aggregation of abrogated proteins within the endoplasmic reticulum (ER) lumen and subsequent activation of the protein kinase RNA-like endoplasmic reticulum kinase (PERK)-dependent unfolded protein response (UPR) signaling pathway may also constitute important factors for POAG pathogenesis at the molecular level. Glaucoma is commonly known as a ‘silent thief of sight’, as it remains asymptomatic until later stages, and thus its diagnosis is frequently delayed. Thereby, detailed knowledge about the glaucoma pathophysiology is necessary to develop both biochemical and genetic tests to improve its early diagnosis as well as develop a novel, ground-breaking treatment strategy, as currently used medical therapies against glaucoma are limited and may evoke numerous adverse side-effects in patients.
Collapse
|
21
|
Navarrete Argüello J, Bello López Portillo H, Cantero Vergara MA, Sierra Acevedo GA, Ruíz Salgado K, Nieto Aguilar MV, Aguilar Pérez MA, Ramos Hernández SY, Zaragoza Herrera A, de la Torre Tovar JD. Intraocular pressure fluctuations in patients implanted with an implantable collamer lens (ICL V4c). Three-month follow-up. ACTA ACUST UNITED AC 2019; 94:367-376. [PMID: 31266666 DOI: 10.1016/j.oftal.2019.05.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 05/02/2019] [Accepted: 05/10/2019] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Fluctuating elevated intraocular pressure (IOP) is one of the complications of an implantable collamer lens (ICL), and its alteration is a predictive factor for the development of glaucoma. MATERIAL AND METHODS A prospective, cross-sectional analytic study was conducted on patients suitable for ICL implantation. Complete clinical and biometric work-ups were performed, as well as night-time IOP curve, in supine position, with 4 determinations, in order to assess fluctuation, considering abnormal with a value higher than 5 mmHg. Patients underwent surgery with conventional technique and three months after the work-ups were repeated, including a night-time IOP curve to assess any changes in IOP fluctuations. RESULTS A total of 31 eyes of 16 patients were studied. Mean IOP fluctuation in the preoperative assessment was 3.35 ± 2 mmHg, whereas the postoperative mean was 3.0 ± 2.2 mmHg, with the difference not being statistically significant. Visual acuity and capacity, as well as spheric equivalent did show a statistically significant improvement. There were 6 cases of complications, which were related to a higher vault and a greater ICL size. There was no relationship between these findings and the angle grade, pigment, and the level of training of the surgeon. CONCLUSIONS The effect of an ICL on IOP fluctuations, has been studied for the first time, which was found to be not statistically significant. As in previous publications, the procedure was safe and reproducible, adding the fact that the level of training of the surgeon is not a determining factor in these findings.
Collapse
Affiliation(s)
| | | | | | | | - K Ruíz Salgado
- Hospital Central Militar, México, Ciudad de México, México
| | | | | | | | | | | |
Collapse
|
22
|
Sidhu T, Desai A, Gagrani M, Dada T. Phacomorphic glaucoma in a high myope with phakic intraocular lens. BMJ Case Rep 2019; 12:12/2/e227096. [PMID: 30804159 DOI: 10.1136/bcr-2018-227096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
We report a case of a young, one-eyed woman with high myopia who presented to our emergency department with sudden onset painful diminution of vision in the right eye after undergoing laser treatment. Her right eye had a phakic intraocular lens (pIOL) implantation 4 years back and her left eye had absent light perception. She was diagnosed as right eye lens induced secondary angle closure glaucoma with pIOL touching the corneal endothelium and left eye atrophic bulbi. She was admitted under eye emergency for medical intraocular pressure control followed by pIOL explantation with lens aspiration of the cataractous lens and posterior chamber intraocular lens implantation.
Collapse
Affiliation(s)
- Talvir Sidhu
- Department of Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, New Delhi, India
| | - Arjun Desai
- Department of Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, New Delhi, India
| | - Meghal Gagrani
- Department of Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, New Delhi, India
| | - Tanuj Dada
- Department of Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, New Delhi, India
| |
Collapse
|