1
|
Dall’Asta A, Melito C, Ghi T. Intrapartum Ultrasound Guidance to Make Safer Any Obstetric Intervention: Fetal Head Rotation, Assisted Vaginal Birth, Breech Delivery of the Second Twin. Clin Obstet Gynecol 2024; 67:730-738. [PMID: 39431493 PMCID: PMC11495479 DOI: 10.1097/grf.0000000000000891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2024]
Abstract
Intrapartum ultrasound (US) is more reliable than clinical assessment in determining parameters of crucial importance to optimize the management of labor including the position and station of the presenting part. Evidence from the literature supports the role of intrapartum US in predicting the outcome of labor in women diagnosed with slow progress during the first and second stage of labor, and randomized data have demonstrated that transabdominal US is far more accurate than digital examination in assessing fetal position before performing an instrumental delivery. Intrapartum US has also been shown to outperform the clinical skills in predicting the outcome and improving the technique of instrumental vaginal delivery. On this basis, some guidelines recommend intrapartum US to ascertain occiput position before performing an instrumental delivery. Manual rotation of occiput posterior position (MROP) and assisted breech delivery of the second twin are other obstetric interventions that can be performed during the second stage of labor with the support of intrapartum US. In this review article we summarize the existing evidence on the role of intrapartum US in assisting different types of obstetric intervention with the aim to improve their safety.
Collapse
|
2
|
Sanchez M, Berveiller P, Behal H, Tursack A, Plurien A, Ghesquière L, Garabedian C. Impact of body mass index on sonographic measurement of head perineum distance before operative vaginal delivery. Int J Gynaecol Obstet 2024; 167:368-373. [PMID: 38736297 DOI: 10.1002/ijgo.15568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2024] [Revised: 04/14/2024] [Accepted: 04/20/2024] [Indexed: 05/14/2024]
Abstract
OBJECTIVE To evaluate the impact of body mass index (BMI) on sonographic measurement of head perineum distance (HPD) before operative vaginal delivery (OVD). METHODS This was a single-center retrospective cohort study (Lille, France) conducted from March 1, 2019 to October 31, 2020 including all singleton and OVD. HPD measurement was systematically performed without and with compression on the perineum soft tissues. The level of station was defined by vaginal examination and three maternal BMI groups were defined (normal BMI [<24.9 kg/m2] vs overweight [25-29.9 kg/m2] vs obese [≥30 kg/m2]). HPD measures were compared between BMI groups and compression, in distinct level of station, using a two-factor analysis of variance including BMI groups, the compression, and the interaction term BMI group compression. RESULTS A total of 775 women were included: 488 with normal BMI, 181 overweight patients and 106 obese patients. The measurement of HPD before OVD without and with compression on the soft tissues was significantly different between the BMI groups only in the lower part, particularly between normal BMI and obese patients (mean difference (95% CI): 6.6 mm (4.0 to 9.2) without compression; 3.8 (1.1 to 6.4) with compression). CONCLUSION The values of HPD without and with compression on the soft tissues on the maternal perineum were different according to the maternal BMI concerning lower part station. Thus, it seems important to define thresholds of HPD measures corresponding to each head station levels according to maternal BMI.
Collapse
Affiliation(s)
| | - Paul Berveiller
- Department of Gynecology and Obstetrics, Poissy-Saint Germain Hospital, Poissy, France
- UMR 1198-BREED, RHuMA, INRAE, Paris Saclay University, Montigny-Le-Bretonneux, France
| | - Hélène Behal
- Department of Biostatistics, CHU Lille, Lille, France
| | | | - Alix Plurien
- Department of Obstetrics, CHU Lille, Lille, France
| | - Louise Ghesquière
- Department of Obstetrics, CHU Lille, Lille, France
- ULR 2694-METRICS: Health Technology and Medical Practice Assessment, University of Lille, Lille, France
| | - Charles Garabedian
- Department of Obstetrics, CHU Lille, Lille, France
- ULR 2694-METRICS: Health Technology and Medical Practice Assessment, University of Lille, Lille, France
| |
Collapse
|
3
|
Romero R, Sabo Romero V, Kalache KD, Stone J. Parturition at term: induction, second and third stages of labor, and optimal management of life-threatening complications-hemorrhage, infection, and uterine rupture. Am J Obstet Gynecol 2024; 230:S653-S661. [PMID: 38462251 DOI: 10.1016/j.ajog.2024.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
Childbirth is a defining moment in anyone's life, and it occurs 140 million times per year. Largely a physiologic process, parturition does come with risks; one mother dies every two minutes. These deaths occur mostly among healthy women, and many are considered preventable. For each death, 20 to 30 mothers experience complications that compromise their short- and long-term health. The risk of birth extends to the newborn, and, in 2020, 2.4 million neonates died, 25% in the first day of life. Hence, intrapartum care is an important priority for society. The American Journal of Obstetrics & Gynecology has devoted two special Supplements in 2023 and 2024 to the clinical aspects of labor at term. This article describes the content of the Supplements and highlights new developments in the induction of labor (a comparison of methods, definition of failed induction, new pharmacologic agents), management of the second stage, the value of intrapartum sonography, new concepts on soft tissue dystocia, optimal care during the third stage, and common complications that account for maternal death, such as infection, hemorrhage, and uterine rupture. All articles are available to subscribers and non-subscribers and have supporting video content to enhance dissemination and improve intrapartum care. Our hope is that no mother suffers because of lack of information.
Collapse
Affiliation(s)
- Roberto Romero
- Pregnancy Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, US Department of Health and Human Services, Bethesda, MD; Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI; Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI.
| | | | - Karim D Kalache
- Department of Clinical Obstetrics and Gynecology, Weill Cornell Medical College-Qatar Division, Doha, Qatar; Division of Maternal-Fetal Medicine, Women's Services, Sidra Medicine, Doha, Qatar
| | - Joanne Stone
- Department of Obstetrics and Gynecology, Icahn School of Medicine at Mount Sinai, New York, NY
| |
Collapse
|
4
|
Mebratu A, Ahmed A, Zemeskel AG, Alemu A, Temesgen T, Molla W, Figa Z. Prevalence, indications and fetal outcomes of operative vaginal delivery in Sub-Saharan Africa, systematic review, and meta-analysis. BMC Womens Health 2023; 23:95. [PMID: 36894978 PMCID: PMC9996922 DOI: 10.1186/s12905-023-02224-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 02/13/2023] [Indexed: 03/11/2023] Open
Abstract
PURPOSE This systematic review and meta-analysis is intended to assess the prevalence, indications, and fetal outcome of operative vaginal delivery in sub-Saharan Africa. METHOD In this study, 17 studies with a total population of 190,900 were included in both systematic review and meta-analysis. Search for relevant articles was done by using international online databases (like Google Scholar, PubMed, HINARI, EMBASE, Web of Science, and African journals) and online repositories of Universities in Africa. The JOANNA Briggs Institute standard data extraction format was used to extract and appraise high-quality articles before being included in this study. The Cochran Q and I2 statistical tests were used to test the heterogeneity of the studies. The publication bias was tested by a Funnel plot and Egger's test. The overall pooled prevalence, indications, and fetal outcome of operative vaginal delivery along a 95% CI using forest plots and tables. RESULT The overall pooled prevalence of operative vaginal delivery in sub-Saharan Africa was 7.98% (95% CI; 5.03-10.65; I2 = 99.9%, P < 0.001). The indications of operative vaginal delivery in sub-Saharan African countries include the prolonged second stage of labor 32.81%, non-reassuring fetal heart rate 37.35%, maternal exhaustion 24.81%, big baby 22.37%, maternal cardiac problems 8.75%, and preeclampsia/eclampsia 2.4%. Regarding the fetal outcome, favourable fetal outcomes were 55% (95% CI: 26.04, 84.44), p = < 0.56, I2: 99.9%). From those births with unfavourable outcomes, the need for the resuscitation of new-born was highest 28.79% followed by poor 5th minute Apgar score, NICU admission, and fresh stillbirth, 19.92, 18.8, and 3.59% respectively. CONCLUSION The overall prevalence of operative vaginal delivery (OVD) in sub-Saharan Africa was slightly higher compared to other countries. To reduce the increased applications and adverse fetal outcomes of OVD, capacity building for obstetrics care providers and drafting guidelines are required.
Collapse
Affiliation(s)
- Andualem Mebratu
- Dilla University College of the Health and Medical Science Department of Midwifery, PO. BOX 419, Dilla, Ethiopia
| | - Abbas Ahmed
- Dilla University College of the Health and Medical Science Department of Midwifery, PO. BOX 419, Dilla, Ethiopia
| | - Addisu Getnet Zemeskel
- Dilla University College of the Health and Medical Science Department of Midwifery, PO. BOX 419, Dilla, Ethiopia
| | - Asrat Alemu
- Dilla University College of the Health and Medical Science Department of Midwifery, PO. BOX 419, Dilla, Ethiopia
| | - Tesfaye Temesgen
- Dilla University College of the Health and Medical Science Department of Midwifery, PO. BOX 419, Dilla, Ethiopia
| | - Wondwosen Molla
- Dilla University College of the Health and Medical Science Department of Midwifery, PO. BOX 419, Dilla, Ethiopia
| | - Zerihun Figa
- Dilla University College of the Health and Medical Science Department of Midwifery, PO. BOX 419, Dilla, Ethiopia
| |
Collapse
|
5
|
Katzir T, Brezinov Y, Khairish E, Hadad S, Vaisbuch E, Levy R. Intrapartum ultrasound use in clinical practice as a predictor of delivery mode during prolonged second stage of labor. Arch Gynecol Obstet 2023; 307:763-770. [PMID: 35576076 DOI: 10.1007/s00404-022-06469-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 02/15/2022] [Indexed: 11/02/2022]
Abstract
PURPOSE To determine the validity of intrapartum ultrasound (IPUS), and particularly the angle of progression (AOP), in predicting delivery mode when measured in real-life clinical practice among women with protracted second stages of labor. METHODS Using electronic medical records, nulliparous women with a second stage of labor of ≥ 3 h ("prolonged") and a documented AOP measurement during the second stage were identified. The ability of a single AOP measurement in "prolonged" second stage to predict a vaginal delivery (VD) was assessed. Fetal head descent, measured by AOP change/h (calculated from serial measurements), was compared between women who delivered vaginally and those who had a cesarean delivery (CD) for arrest of descent. RESULTS Of the 191 women who met the inclusion criteria, 62 (32.5%) delivered spontaneously, 96 (50.2%) had a vacuum extraction (VE) and 33 (17.3%) had a CD. The mean AOP was wider among women who had VD (spontaneous or VE) compared to those who had CD (153° ± 19 vs. 133° ± 17, p < 0.001). Wider AOPs were associated with higher rates of VD and an AOP ≥ 127° was associated with a VD rate of 88.6% (148/167). Among the 87 women who had more than one AOP measurement, the mean AOP change per hour was higher in the VD group than in the CD group (15.1° ± 11.4° vs. 6.2° ± 6.3°, p < 0.001). CONCLUSION Ultrasound-assessed fetal head station in nulliparous women with a protracted second stage of labor can be an accurate and objective additive tool in predicting the mode and interval time to delivery in real-life clinical practice.
Collapse
Affiliation(s)
- Tamar Katzir
- Department of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel
| | - Yoav Brezinov
- Department of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel
| | - Ella Khairish
- Department of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel
| | - Shira Hadad
- Department of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel
| | - Edi Vaisbuch
- Department of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel
| | - Roni Levy
- Department of Obstetrics and Gynecology, Kaplan Medical Center, 76100, Rehovot, Israel.
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.
| |
Collapse
|
6
|
Zhou P, Chen H, Zhang Y, Yao M. Nomogram based on the final antepartum ultrasound features before delivery for predicting failed spontaneous vaginal delivery in nulliparous women. Front Surg 2023; 9:1048866. [PMID: 36684290 PMCID: PMC9852332 DOI: 10.3389/fsurg.2022.1048866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 11/07/2022] [Indexed: 01/09/2023] Open
Abstract
Background Accurate identification of nulliparous women with failed spontaneous vaginal delivery (SVD) is crucial to minimize the hazards associated with obstetrical intervention (OI). While abnormal labor progression can be identified with intrapartum ultrasonography, labor-related complications may be unavoidable due to the limited time window left to the obstetrician. Antepartum ultrasound enables sufficient obstetric planning. However, there is typically a longer gap between ultrasound assessment and delivery that often lowers the prediction accuracy compared to intrapartum ultrasonography. Objective In this study, antepartum ultrasound assessment was included to each fetal ultrasound examination after 36 weeks of gestation until the onset of labor. We aim to establish a nomogram to predict the likelihood of failed SVD in nulliparous women using the last antepartum ultrasound findings before labor beginning. Methods Of the 2,143 nulliparous women recruited, 1,373 were included in a training cohort and 770 in a validation cohort, based on their delivery date. Maternal and perinatal characteristics, as well as perinatal ultrasound parameters were collected. In the training cohort, the screened correlates of SVD failure were used to develop a nomogram for determining whether a nulliparous woman would experience SVD failure. This model was validated in both training and validation cohorts. Results SVD failure affected 217 nulliparous women (10.13%). In the training cohort, SVD failure was independently associated with BMI [odds ratio (OR) = 1.636], FHC (OR = 1.194), CL (OR = 1.398), and PCA (OR = 0.824) (all P < 0.05). They constituted a nomogram to estimate the individual risk of SVD failure. The model obtained clinical net benefits in both the training and validation cohorts and was validated to present strong discrimination and calibration. Conclusion The developed nomogram based on the last antepartum ultrasound findings may be helpful in avoiding OI and its related complications by assessing the likelihood of a failed SVD in nulliparous women.
Collapse
Affiliation(s)
- Ping Zhou
- Department of Gynecology, Wuhan Children's Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology, Wuhan, China
| | - Han Chen
- Department of Ultrasound, Wuhan Children's Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology, Wuhan, China
| | - Yang Zhang
- Department of Ultrasound, Wuhan Children's Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology, Wuhan, China,Correspondence: Yang Zhang Min Yao
| | - Min Yao
- Department of Pediatrics, , Wuhan Children's Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology, Wuhan, China,Correspondence: Yang Zhang Min Yao
| |
Collapse
|
7
|
Cohen G, Schreiber H, Shalev Ram H, Ovadia M, Shechter-Maor G, Biron-Shental T. Can We Predict Feto-Maternal Adverse Outcomes of Vacuum Extraction? Geburtshilfe Frauenheilkd 2022; 82:1274-1282. [PMID: 36339635 PMCID: PMC9633228 DOI: 10.1055/a-1904-6025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Accepted: 07/16/2022] [Indexed: 11/07/2022] Open
Abstract
Introduction Vacuum extraction (VE) is an important modality in modern obstetrics, yet sometimes results in maternal or neonatal adverse outcomes, which can cause a lifetime disability. We aimed to characterize potential risk factors for adverse outcomes that in retrospect would have led the physician to avoid the procedure. Materials and Methods Retrospective cohort of 3331 singleton pregnancies, ≥ 34 w delivered by VE. 263 deliveries (7.9%) incurred a VE-related feto-maternal adverse outcome, defined as one or more of the following: 3-4th-degree perineal laceration, subgaleal hematoma, intracranial hemorrhage, shoulder dystocia, clavicular fracture, Erb's palsy or fracture of humerus. 3068 deliveries (92.1%) did not have VE-related adverse outcomes. Both groups were compared to determine potential risk factors for VE adverse outcomes. Results Multivariable regression found seven independent risk factors for VE-related feto-maternal adverse outcomes: Nulliparity - with an odds ratio (OR) of 1.82 (95% CI = 1.11-2.98, p = 0.018), epidural anesthesia (OR 1.99, CI = 1.42-2.80, p < 0.001), Ventouse-Mityvac (VM) cup (OR 1.86, CI = 1.35-2.54, p < 0.001), prolonged second stage as indication for VE (OR 1.54, CI = 1.11-2.15, p = 0.010), cup detachment (OR 1.66, CI = 1.18-2.34, p = 0.004), increasing procedure duration (OR 1.07 for every additional minute, CI = 1.03-1.11, p < 0.001) and increasing neonatal birthweight (OR 3.42 for every additional kg, CI = 2.33-5.02, p < 0.001). Occiput anterior (OA) position was a protective factor (OR 0.62, CI = 0.43-0.89, p = 0.010). Conclusions VE-related adverse outcomes can be correlated to clinical characteristics, such as nulliparity, epidural anesthesia, VM cup, prolonged second stage as indication for VE, cup detachment, prolonged procedure duration and increasing neonatal weight. OA position was a protective factor. This information may assist medical staff to make an informed decision whether to choose VE or cesarean delivery (CD).
Collapse
Affiliation(s)
- Gal Cohen
- 37253Department of Obstetrics and Gynecology, Meir Medical Center, Kfar Saba, Israel,58408Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel,Korrespondenzadresse Gal Cohen 37253Meir Medical Center, Department of Obstetrics and GynecologyTchernichovsky
St. 5944281 Kfar SabaIsrael
| | - Hanoch Schreiber
- 37253Department of Obstetrics and Gynecology, Meir Medical Center, Kfar Saba, Israel,58408Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Hila Shalev Ram
- 37253Department of Obstetrics and Gynecology, Meir Medical Center, Kfar Saba, Israel,58408Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Michal Ovadia
- 37253Department of Obstetrics and Gynecology, Meir Medical Center, Kfar Saba, Israel,58408Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Gil Shechter-Maor
- 37253Department of Obstetrics and Gynecology, Meir Medical Center, Kfar Saba, Israel,58408Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Tal Biron-Shental
- 37253Department of Obstetrics and Gynecology, Meir Medical Center, Kfar Saba, Israel,58408Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
8
|
Naqvi M, Jaffe EF, Goldfarb IT, Bryant AS, Wylie BJ, Kaimal AJ. Prolonged Second Stage of Labor and Anal Sphincter Injury in a Contemporary Cohort of Term Nulliparas. Am J Perinatol 2022; 39:937-943. [PMID: 33080634 DOI: 10.1055/s-0040-1718878] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE This study aimed to assess whether a prolonged second stage of labor is an independent predictor of obstetric anal sphincter injury (OASI) in a contemporary cohort of nulliparous and term parturients, and to evaluate whether predelivery factors can accurately predict OASI. STUDY DESIGN This was a nested case-control study within a cohort of consecutive nulliparous term parturients with a singleton gestation who underwent a vaginal delivery at a single institution between January 2014 and January 2015. Cases were defined as women with a third- or fourth-degree laceration at the time of delivery, and controls were women without a third- or fourth-degree laceration. A prolonged second stage was defined as a second stage of ≥3 hours. Univariable and multivariable regression analyses were performed to examine the relationship between prolonged second stage of labor and third- or fourth-degree lacerations. Receiver operator curves were developed to assess the predictive capacity of predelivery information for third- and fourth-degree lacerations. RESULTS Of 1,197 births, 63 women had third- or fourth-degree lacerations (5.3%). With each additional hour of the second stage, the rate of OASI increased, with 2.9% of women with a second stage of <1 hour with OASI, 3.5% between 1 and 2 hours, 5.7% between 2 and 3 hours, 7.8% between 3 and 4 hours, 16.1% between 4 and 5 hours, and 28.6% among women with a second stage length >5 hours (p < 0.001). In multivariable regression analysis, operative vaginal delivery (adjusted odds ratio [aOR] = 5.92, 95% confidence interval [CI]: 3.17-11.07) and a prolonged second stage (aOR = 1.92, 95% CI: 1.06-3.51) were independent predictors of third- and fourth-degree lacerations. A predictive model was developed from these results (area under the curve [AUC] = 0.75, 95% CI: 0.68-0.81). CONCLUSION Prolonged second stage of labor is a predictor of OASI, after adjustment for operative vaginal delivery. A model using predelivery risk factors has a reasonable prediction of OASI. KEY POINTS · Prolonged second stage labor is associated with obstetric anal sphincter injury in term nulliparas.. · Predelivery risk factors reasonably predict obstetric anal sphincter injury in term nulliparas.. · Improved models are needed for clinical risk-stratification..
Collapse
Affiliation(s)
- Mariam Naqvi
- Division of Maternal Fetal Medicine Department of Obstetrics and Gynecology, Cedars Sinai Medical Center, Los Angeles, California.,Division of Maternal Fetal Medicine Department of Obstetrics and Gynecology, Massachusetts General Hospital, Boston, Massachusetts
| | - Elana F Jaffe
- Department of Maternal, Child, and Family Health, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, North Carolina.,Department of Social Medicine, Center for Bioethics, University of North Carolina, Chapel Hill, North Carolina
| | - Ilona T Goldfarb
- Division of Maternal Fetal Medicine Department of Obstetrics and Gynecology, Massachusetts General Hospital, Boston, Massachusetts
| | - Allison S Bryant
- Division of Maternal Fetal Medicine Department of Obstetrics and Gynecology, Massachusetts General Hospital, Boston, Massachusetts
| | - Blair J Wylie
- Division of Maternal Fetal Medicine Department of Obstetrics and Gynecology, Massachusetts General Hospital, Boston, Massachusetts.,Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, Beth Israel Deaconess Medical Center, Boston, Massachusetts
| | - Anjali J Kaimal
- Division of Maternal Fetal Medicine Department of Obstetrics and Gynecology, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|
9
|
Plurien A, Berveiller P, Drumez E, Hanssens S, Subtil D, Garabedian C. Ultrasound assessment of fetal head position and station before operative delivery: can it predict difficulty? J Gynecol Obstet Hum Reprod 2022; 51:102336. [DOI: 10.1016/j.jogoh.2022.102336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 01/31/2022] [Accepted: 02/07/2022] [Indexed: 11/29/2022]
|
10
|
Shemer O, Shemer A, Ganor Paz Y, Rosen H, Tovbin J, Barzilay E. Association between level of training and reliability of intrapartum transperineal ultrasound measurement of angle of progression. J Matern Fetal Neonatal Med 2021; 35:9093-9097. [PMID: 34882060 DOI: 10.1080/14767058.2021.2014811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
OBJECTIVES Intrapartum transperineal ultrasound (ITU) is an accepted tool for assessing fetal head position and station prior to operative vaginal delivery attempt. However, the validity of intrapartum ultrasound in real-life obstetrics with operators at different proficiency level is yet to be established. We aimed to investigate the association between operator level of training and reliability of angle of progression (AOP) measurements in real-life obstetrics. METHODS This was a retrospective study in one university medical center. We included women who underwent ITU for the measurement of AOP, before vacuum assisted delivery from November 2017 to September 2020. AOP measurements performed by residents and their correlation to head station were compared to those performed by specialists. RESULTS A total of 320 cases met the inclusion criteria. In 234 of them, AOP measurements were performed by specialists and in 86 by residents. Average AOP for each station was similar between the specialists and the residents groups, indicating similar accuracy. However, measurements in the residents group were more scattered (median deviation 11.4° vs. 8.9°, respectively, p = .021), indicating poorer precision. CONCLUSIONS AOP measurements performed by obstetrics and gynecology (OBGYN) specialists are more precise than those performed by residents. Efforts should be taken to improve ITU training and to implement assessment of performance programs.
Collapse
Affiliation(s)
- Ofer Shemer
- Department of Obstetrics and Gynecology, Samson Assuta Ashdod University Hospital, Ashdod, Israel.,Faculty of Health Sciences, Ben-Gurion University of the Negev, Be'er Sheva, Israel
| | - Asaf Shemer
- Department of Obstetrics and Gynecology, Samson Assuta Ashdod University Hospital, Ashdod, Israel.,Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Yael Ganor Paz
- Department of Obstetrics and Gynecology, Samson Assuta Ashdod University Hospital, Ashdod, Israel.,Faculty of Health Sciences, Ben-Gurion University of the Negev, Be'er Sheva, Israel
| | - Hadar Rosen
- Department of Obstetrics and Gynecology, Samson Assuta Ashdod University Hospital, Ashdod, Israel.,Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Josef Tovbin
- Department of Obstetrics and Gynecology, Samson Assuta Ashdod University Hospital, Ashdod, Israel.,Faculty of Health Sciences, Ben-Gurion University of the Negev, Be'er Sheva, Israel
| | - Eran Barzilay
- Department of Obstetrics and Gynecology, Samson Assuta Ashdod University Hospital, Ashdod, Israel.,Faculty of Health Sciences, Ben-Gurion University of the Negev, Be'er Sheva, Israel
| |
Collapse
|
11
|
Wong L, Kwan AHW, Lau SL, Sin WTA, Leung TY. Umbilical cord prolapse: revisiting its definition and management. Am J Obstet Gynecol 2021; 225:357-366. [PMID: 34181893 DOI: 10.1016/j.ajog.2021.06.077] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 06/15/2021] [Accepted: 06/16/2021] [Indexed: 01/26/2023]
Abstract
Umbilical cord prolapse is an unpredictable obstetrical emergency with an incidence ranging from 1 to 6 per 1000 pregnancies. It is associated with high perinatal mortality, ranging from 23% to 27% in low-income countries to 6% to 10% in high-income countries. In this review, we specifically addressed 3 issues. First, its definition is not consistent in the current literature, and "occult cord prolapse" is a misnomer because the cord is still above the cervix. We proposed that cord prolapse, cord presentation, and compound cord presentation should be classified according to the positional relationship among the cord, the fetal presenting part, and the cervix. All of them may occur with either ruptured or intact membranes. The fetal risk is highest in cord prolapse, followed by cord presentation, and lastly by compound cord presentation, which replaces the misnomer "occult cord prolapse." Second, the mainstay of treatment of cord prolapse is urgent delivery, which means cesarean delivery in most cases, unless vaginal delivery is imminent. The urgency depends on the fetal heart rate pattern, which can be bradycardia, recurrent decelerations, or normal. It is most urgent in cases with bradycardia, because a recent study showed that cord arterial pH declines significantly with the bradycardia-to-delivery interval at a rate of 0.009 per minute (95% confident interval, 0.0003-0.0180), and this may indicate an irreversible pathology such as vasospasm or persistent cord compression. However, cord arterial pH does not correlate with either deceleration-to-delivery interval or decision-to-delivery interval, indicating that intermittent cord compression causing decelerations is reversible and less risk. Third, while cesarean delivery is being arranged, different maneuvers should be adopted to relieve cord compression by elevating the fetal presenting part and to prevent further cord prolapse beyond the vagina. A recent study showed that the knee-chest position provides the greatest elevation effect, followed by filling of the maternal urinary bladder with 500 mL of fluid, and then the Trendelenburg position (15°) and other maneuvers. However, each maneuver has its own advantages and limitations; thus, they should be applied wisely and with great caution, depending on the actual clinical situation. Therefore, we have proposed an algorithm to guide this acute management.
Collapse
Affiliation(s)
- Lo Wong
- Department of Obstetrics and Gynaecology, Faculty of Medicine, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong, China
| | - Angel Hoi Wan Kwan
- Department of Obstetrics and Gynaecology, Faculty of Medicine, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong, China
| | - So Ling Lau
- Department of Obstetrics and Gynaecology, Faculty of Medicine, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong, China
| | - Wing To Angela Sin
- Department of Obstetrics and Gynaecology, Faculty of Medicine, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong, China
| | - Tak Yeung Leung
- Department of Obstetrics and Gynaecology, Faculty of Medicine, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong, China.
| |
Collapse
|
12
|
Kwan AHW, Chaemsaithong P, Wong L, Tse WT, Hui ASY, Poon LC, Leung TY. Transperineal ultrasound assessment of fetal head elevation by maneuvers used for managing umbilical cord prolapse. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2021; 58:603-608. [PMID: 33219729 DOI: 10.1002/uog.23544] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 10/14/2020] [Accepted: 11/06/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVE To assess objectively the degree of fetal head elevation achieved by different maneuvers commonly used for managing umbilical cord prolapse. METHODS This was a prospective observational study of pregnant women at term before elective Cesarean delivery. A baseline assessment of fetal head station was performed with the woman in the supine position, using transperineal ultrasound for measuring the parasagittal angle of progression (psAOP), head-symphysis distance (HSD) and head-perineum distance (HPD). The ultrasonographic measurements of fetal head station were repeated during different maneuvers, including elevation of the maternal buttocks using a wedge, knee-chest position, Trendelenburg position with a 15° tilt and filling the maternal urinary bladder with 100 mL, 300 mL and 500 mL of normal saline. The measurements obtained during the maneuvers were compared with the baseline measurements. RESULTS Twenty pregnant women scheduled for elective Cesarean section at term were included in the study. When compared with baseline (median psAOP, 103.6°), the knee-chest position gave the strongest elevation effect, with the greatest reduction in psAOP (psAOP, 80.7°; P < 0.001), followed by filling the bladder with 500 mL (psAOP, 89.9°; P < 0.001) and 300 mL (psAOP, 94.4°; P < 0.001) of normal saline. Filling the maternal bladder with 100 mL of normal saline (psAOP, 96.1°; P = 0.001), the Trendelenburg position (psAOP, 96.8°; P = 0.014) and elevating the maternal buttocks (psAOP, 98.3°; P = 0.033) gave modest elevation effects. Similar findings were reported for HSD and HPD. The fetal head elevation effects of the knee-chest position, Trendelenburg position and elevation of the maternal buttocks were independent of the initial fetal head station, but that of bladder filling was greater when the initial head station was low. CONCLUSIONS To elevate the fetal presenting part, the knee-chest position provides the best effect, followed by filling the maternal urinary bladder with 500 mL then 300 mL of fluid, respectively. Filling the bladder with 100 mL of fluid, the Trendelenburg position and elevation of the maternal buttocks have modest effects. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- A H W Kwan
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR
| | - P Chaemsaithong
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR
| | - L Wong
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR
| | - W T Tse
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR
| | - A S Y Hui
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR
| | - L C Poon
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR
| | - T Y Leung
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR
| |
Collapse
|
13
|
Youssef A, Brunelli E, Pilu G, Dietz HP. The maternal pelvic floor and labor outcome. Am J Obstet Gynecol MFM 2021; 3:100452. [PMID: 34365028 DOI: 10.1016/j.ajogmf.2021.100452] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 07/13/2021] [Accepted: 07/20/2021] [Indexed: 12/29/2022]
Abstract
Vaginal birth is the major cause of pelvic floor damage. The development of transperineal ultrasound has improved our understanding of the relationship between vaginal birth and pelvic floor dysfunction. The female pelvic floor dimensions and function can be assessed reliably in pregnant women. Maternal pushing associated with pelvic floor muscle relaxation is the central requirement of vaginal birth. Many studies have evaluated the role of the pelvic floor on labor outcomes. Smaller levator hiatal dimensions and incomplete or absent levator ani muscle relaxation seem to be associated with a longer duration of the second stage of labor and a higher risk of cesarean and operative deliveries. Here, we presented an overview of the current knowledge of the correlation between female pelvic floor dimension and function, as assessed by transperineal ultrasound, and labor outcome.
Collapse
Affiliation(s)
- Aly Youssef
- Obstetric Unit, Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy (Drs Youssef, Brunelli, and Pilu); Istituto di Ricovero e Cura a Carattere Scientifico Azienda Ospedaliero-Universitaria S. Orsola-Malpighi, Bologna, Italy (Drs Youssef, Brunelli, and Pilu).
| | - Elena Brunelli
- Obstetric Unit, Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy (Drs Youssef, Brunelli, and Pilu); Istituto di Ricovero e Cura a Carattere Scientifico Azienda Ospedaliero-Universitaria S. Orsola-Malpighi, Bologna, Italy (Drs Youssef, Brunelli, and Pilu)
| | - Gianluigi Pilu
- Obstetric Unit, Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy (Drs Youssef, Brunelli, and Pilu); Istituto di Ricovero e Cura a Carattere Scientifico Azienda Ospedaliero-Universitaria S. Orsola-Malpighi, Bologna, Italy (Drs Youssef, Brunelli, and Pilu)
| | - Hans Peter Dietz
- Sydney Medical School Nepean, Department of O&G, University of Sydney, Penrith, New South Wales, Australia (Dr Dietz)
| |
Collapse
|
14
|
Ghi T. Intrapartum ultrasound and evidence-based medicine: a necessary but challenging marriage. Am J Obstet Gynecol MFM 2021; 3:100428. [PMID: 34303655 DOI: 10.1016/j.ajogmf.2021.100428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 06/21/2021] [Indexed: 02/07/2023]
Affiliation(s)
- Tullio Ghi
- Unit of Obstetrics and Gynecology, Department of Medicine and Surgery, University of Parma, Parma, Italy.
| |
Collapse
|
15
|
The role of the angle of progression in the prediction of the outcome of occiput posterior position in the second stage of labor. Am J Obstet Gynecol 2021; 225:81.e1-81.e9. [PMID: 33508312 DOI: 10.1016/j.ajog.2021.01.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 01/20/2021] [Accepted: 01/20/2021] [Indexed: 01/06/2023]
Abstract
BACKGROUND Occiput posterior position is the most frequent cephalic malposition, and its persistence at delivery is associated with a higher risk of maternal and perinatal morbidity. Diagnosis and management of occiput posterior position remain a clinical challenge. This is partly caused by our inability to predict fetuses who will spontaneously rotate into occiput anterior from those who will have persistent occiput posterior position. The angle of progression, measured with transperineal ultrasound, represents a reliable tool for the evaluation of fetal head station during labor. The relationship between the persistence of occiput posterior position and fetal head station in the second stage of labor has not been previously assessed. OBJECTIVE This study aimed to evaluate the role of fetal head station, as measured by the angle of progression, in the prediction of persistent occiput posterior position and the mode of delivery in the second stage of labor. STUDY DESIGN We recruited a nonconsecutive series of women with posterior occiput position diagnosed by transabdominal ultrasound in the second stage of labor. For each woman, a transperineal ultrasound was performed to measure the angle of progression at rest. We compared the angle of progression between women who delivered fetuses in occiput anterior position and those with persistent occiput posterior position at delivery. Receiver operating characteristics curves were performed to evaluate the accuracy of the angle of progression in the prediction of persistent occiput posterior position. Finally, we performed a multivariate logistic regression to determine independent predictors of persistent occiput posterior position. RESULTS Overall, 63 women were included in the analysis. Among these, 39 women (62%) delivered in occiput anterior position, whereas 24 (38%) delivered in occiput posterior position (persistent occiput posterior position). The angle of progression was significantly narrower in the persistent occiput posterior position group than in women who delivered fetuses in occiput anterior position (118.3°±12.2° vs 127.5°±10.5°; P=.003). The area under the receiver operating characteristics curve was 0.731 (95% confidence interval, 0.594-0.869) with an estimated best cutoff range of 121.5° (sensitivity of 72% and specificity of 67%). On logistic regression analysis, the angle of progression was found to be independently associated with persistence of occiput posterior position (odds ratio, 0.942; 95% confidence interval, 0.889-0.998; P=.04). Finally, women who underwent cesarean delivery had significantly narrower angle of progression than women who had a vaginal delivery (113.5°±8.1 vs 128.0°±10.7; P<.001). The area under the receiver operating characteristics curve for the prediction of cesarean delivery was 0.866 (95% confidence interval, 0.761-0.972). At multivariable logistic regression analysis including the angle of progression, parity, and gestational age at delivery, the angle of progression was found to be the only independent predictor associated with cesarean delivery (odds ratio, 0.849; 95% confidence interval, 0.775-0.0930; P<.001). CONCLUSION In fetuses with occiput posterior at the beginning of the second stage of labor, narrower values of the angle of progression are associated with higher rates of persistent occiput posterior position at delivery and a higher risk of cesarean delivery.
Collapse
|
16
|
Hjartardóttir H, Lund SH, Benediktsdóttir S, Geirsson RT, Eggebø TM. Fetal descent in nulliparous women assessed by ultrasound: a longitudinal study. Am J Obstet Gynecol 2021; 224:378.e1-378.e15. [PMID: 33039395 DOI: 10.1016/j.ajog.2020.10.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 09/25/2020] [Accepted: 10/02/2020] [Indexed: 12/24/2022]
Abstract
BACKGROUND Ultrasound measurements offer objective and reproducible methods to measure the fetal head station. Before these methods can be applied to assess labor progression, the fetal head descent needs to be evaluated longitudinally in well-defined populations and compared with the existing data derived from clinical examinations. OBJECTIVE This study aimed to use ultrasound measurements to describe the fetal head descent longitudinally as labor progressed through the active phase in nulliparous women with spontaneous onset of labor. STUDY DESIGN This was a single center, prospective cohort study at the Landspitali - The National University Hospital of Iceland, Reykjavik, Iceland, from January 2016 to April 2018. Nulliparous women with a single fetus in cephalic presentation and spontaneous labor onset at a gestational age of ≥37 weeks, were eligible. Participant inclusion occurred during admission for women with an established active phase of labor or at the start of the active phase for women admitted during the latent phase. The active phase was defined as an effaced cervix dilated to at least 4 cm in women with regular contractions. According to the clinical protocol, vaginal examinations were done at entry and subsequently throughout labor, paired each time with a transperineal ultrasound examination by a separate examiner, with both examiners being blinded to the other's results. The measurements used to assess the fetal head station were the head-perineum distance and angle of progression. Cervical dilatation was examined clinically. RESULTS The study population comprised 99 women. The labor patterns for the head-perineum distance, angle of progression, and cervical dilatation differentiated the participants into 75 with spontaneous deliveries, 16 with instrumental vaginal deliveries, and 8 cesarean deliveries. At the inclusion stage, the cervix was dilated 4 cm in 26 of the women, 5 cm in 30 of the women, and ≥6 cm in 43 women. One cesarean and 1 ventouse delivery were performed for fetal distress, whereas the remaining cesarean deliveries were conducted because of a failure to progress. The total number of examinations conducted throughout the study was 345, with an average of 3.6 per woman. The ultrasound-measured fetal head station both at the first and last examination were associated with the delivery mode and remaining time of labor. In spontaneous deliveries, rapid head descent started around 4 hours before birth, the descent being more gradual in instrumental deliveries and absent in cesarean deliveries. A head-perineum distance of 30 mm and angle of progression of 125° separately predicted delivery within 3.0 hours (95% confidence interval, 2.5-3.8 hours and 2.4-3.7 hours, respectively) in women delivering vaginally. Although the head-perineum distance and angle of progression are independent methods, both methods gave similar mirror image patterns. The fetal head station at the first examination was highest for the fetuses in occiput posterior position, but the pattern of rapid descent was similar for all initial positions in spontaneously delivering women. Oxytocin augmentation was used in 41% of women; in these labors a slower descent was noted. Descent was only slightly slower in the 62% of women who received epidural analgesia. A nonlinear relationship was observed between the fetal head station and dilatation. CONCLUSION We have established the ultrasound-measured descent patterns for nulliparous women in spontaneous labor. The patterns resemble previously published patterns based on clinical vaginal examinations. The ultrasound-measured fetal head station was associated with the delivery mode and remaining time of labor.
Collapse
|
17
|
Evans MI, Britt DW, Evans SM. Mid forceps did not cause "compromised babies" - "compromise" caused forceps: an approach toward safely lowering the cesarean delivery rate. J Matern Fetal Neonatal Med 2021; 35:5265-5273. [PMID: 33494634 DOI: 10.1080/14767058.2021.1876657] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
OBJECTIVE Over 5 decades, Cesarean Delivery rates (CDR) have risen 6-fold while vaginal operative deliveries [VODs] decreased from >20% to ∼3%. Poor outcomes (HIE and cerebral palsy) haven't improved. Potentiating the virtual abandonment of forceps (F), particularly midforceps (Mid), were allegations about various poor neonatal outcomes. Here, we evaluate VOD and CDR outcomes controlling for prior fetal risk metrics (PR) ascertained an hour before birth. METHODS Our 45-year-old database from a labor research unit of moderate/high risk laboring patients (288 NSVDs, 120 Lows, 30 Mids, and 32 CDs) had multiple fetal scalp samples for base excess (BE), pH, cord blood gases (CB), and umbilical artery bloods. ANOVA established relationships between birth methods and outcomes (Cord blood BE and pH and 1 and 5 min Apgar scores); correlations, and two-step multiple regression assessed PR for delivery method and neonatal outcomes. The main outcome measures were correlations of outcome measures with fetal scalp sample BE and pH up to an hour before delivery and fetal reserve index scores scored concurrently. RESULTS NSVDs had the best immediate neonatal outcomes with significantly higher CB pH and BE as compared to forceps and CDs. However, controlling for PR revealed: (1) PR at 1 h before delivery correlated with delivery mode, i.e. the decrements in outcomes were already present before the delivery was performed; and (2) The presumed deleterious effects of interventional deliveries, per se, were significantly reduced, and (3) Fetal Reserve Index predicted neonatal outcomes better than fetal scalp sample BE, pH, or delivery mode. CONCLUSION The historical belief that MF deliveries caused poorer outcomes than NSVDs seems mostly backwards. Appreciating PR's impact on delivery routes, and when appropriate, properly performing VODs could safely reduce CDR. If our approach lowered CDR by only ∼2%, in the United States about 80,000 CDs might be avoided, saving ∼$750 Million yearly. In the post pandemic world, safely apportioning medical expenses will be even more critical than previously.
Collapse
Affiliation(s)
- Mark I Evans
- Comprehensive Genetics, Fetal Medicine Foundation of America, New York, NY, USA.,Department of Obstetrics & Gynecology, Icahn School of Medicine at Mt Sinai, Mt Sinai, NY, USA
| | - David W Britt
- Comprehensive Genetics, Fetal Medicine Foundation of America, New York, NY, USA
| | - Shara M Evans
- Comprehensive Genetics, Fetal Medicine Foundation of America, New York, NY, USA.,Gillings School of Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| |
Collapse
|
18
|
di Pasquo E, Ramirez Zegarra R, Kiener AJO, Gobbi L, Dall'Asta A, Fieschi L, Cugini L, Copelli M, Frusca T, Ghi T. Usefulness of an Intrapartum Ultrasound Simulator (IUSim™) for Midwife Training: Results from an RCT. Fetal Diagn Ther 2020; 48:120-127. [PMID: 33296898 DOI: 10.1159/000512047] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Accepted: 10/05/2020] [Indexed: 11/19/2022]
Abstract
INTRODUCTION We conducted a randomized study to determine whether a training session on a dedicated simulator (IUSim™) would facilitate the midwives in learning the technique of transperineal intrapartum ultrasound. METHODS Following a 30-min multimedia presentation including images and videos on how to obtain and measure the angle of progression (AoP) and the head-perineum distance (HPD), 6 midwives with no prior experience in intrapartum ultrasound were randomly split into 2 groups: 3 of them were assigned to the "training group" and 3 to the "control group." The midwives belonging to the former group were taught to measure the 2 sonographic parameters during a 3-h practical session conducted on IUSim™ under the supervision of an expert obstetrician. In the following 3 months, all the 6 midwives were asked to independently perform transperineal ultrasound during their clinical practice and to measure on the acquired images either the AoP or the HPD. The sonographic images were examined in blind by the teaching obstetrician who assigned a 0-3 score to the image quality (IQS) and to the measurement quality (MQS). RESULTS A total of 48 ultrasound images (24 patients) from 5 midwives were acquired and included in the study analysis. A midwife of the "training group" declined participation after the practical session. Independently from the randomization group, the image quality score (IQS + MQS) was significantly higher for the HPD compared with the AoP (2.5 ± 0.66 vs. 1.79 ± 1.14; p = 0.01). In the training group, the MQS of either AoP (2.66 ± 0.5 vs.1.46 ± 1.45. p = 0.038) and the HPD (2.9 ± 0.33 vs. 1.87 ± 0.83 p = 0.002) was significantly higher in comparison with the control group, while the IQS of both measurements was comparable between the 2 groups (1.91 ± 1.24 vs. 2.25 ± 0.865; p = 0.28). CONCLUSION The use of a dedicated simulator may facilitate the midwives in learning how to measure the AoP and the HPD on transperineal ultrasound images.
Collapse
Affiliation(s)
- Elvira di Pasquo
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Ruben Ramirez Zegarra
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.,Frankfurt Oder Klinikum, Frankfurt, Germany
| | - Ariane J O Kiener
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Laura Gobbi
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Andrea Dall'Asta
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Laura Fieschi
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Lodovica Cugini
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Monica Copelli
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Tiziana Frusca
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Tullio Ghi
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy,
| |
Collapse
|
19
|
Abstract
Safe management of the second stage of labor is important. Wait for spontaneous delivery, operative vaginal deliveries and second stage cesarean sections are all options when prolonged second stage occurs. The important question is which option to choose. Fetal head station and fetal head position are used to decide mode of delivery; this has traditionally been decided by performing a digital vaginal examination. Studies have shown that theses clinical examinations of both fetal head station and position are unreliable and that ultrasound might be better option. The International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) published in 2018 guidelines on intrapartum ultrasound and recommends that ultrasound is performed for ascertainment of fetal head position and station before considering or performing an instrumental vaginal delivery for slow progress or arrested labor in the second stage. The determination of the fetal head position, fetal head station and the movement of the fetal head can easily be determined with the help of ultrasound and can help the clinicians in making the right decision on how to proceed when prolonged second stage of labor is diagnosed.
Collapse
Affiliation(s)
- Birgitte H Kahrs
- National Center for Fetal Medicine, Trondheim University Hospital (St Olavs Hospital), Trondheim, Norway - .,Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway -
| |
Collapse
|
20
|
Youssef A, Brunelli E, Montaguti E, Di Donna G, Dodaro MG, Bianchini L, Pilu G. Transperineal ultrasound assessment of maternal pelvic floor at term and fetal head engagement. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 56:921-927. [PMID: 31975450 DOI: 10.1002/uog.21982] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 12/17/2019] [Accepted: 01/14/2020] [Indexed: 06/10/2023]
Abstract
OBJECTIVES To evaluate the association between pelvic floor dimensions in nulliparous women at term and fetal head engagement, as assessed by transperineal ultrasound. METHODS This was a prospective observational study of nulliparous women at term. Before the onset of labor, transperineal ultrasound was used to measure the anteroposterior diameter (APD) of the levator hiatus and the angle of progression (AoP) at rest, on maximum pelvic floor muscle contraction and on maximum Valsalva maneuver (before and after visual feedback). We assessed the correlation between pelvic floor static and dynamic dimensions (levator hiatal APD and levator ani muscle coactivation) and AoP, which is an objective index of fetal head engagement. RESULTS In total, 282 women were included in the analysis. Among these, 211 (74.8%) women had a vaginal delivery while 71 (25.2%) had a Cesarean delivery. AoP was narrower in the Cesarean-delivery group at rest, on maximum pelvic floor muscle contraction and on maximum Valsalva, whereas no differences in levator hiatal APD were found between the two groups. We found a negative correlation between levator hiatal APD at rest, on maximum pelvic floor muscle contraction and on maximum Valsalva and the duration of the second stage of labor. There was a positive correlation between AoP and levator hiatal APD on maximum Valsalva maneuver after visual feedback (r = 0.15, P = 0.01). Women with levator ani muscle contraction on Valsalva maneuver (i.e. coactivation), both pre and post visual feedback, had a narrower AoP at rest and on maximum Valsalva. After visual feedback, women with levator ani muscle coactivation had a longer second stage of labor than did those without (80.8 ± 61.4 min vs 62.9 ± 43.4 min (P = 0.04)). CONCLUSIONS Smaller pelvic floor dimensions and levator ani muscle coactivation are associated with higher fetal head station and with a longer second stage of labor in nulliparous women at term. Copyright © 2020 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- A Youssef
- Department of Obstetrics and Gynecology, Sant'Orsola Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - E Brunelli
- Department of Obstetrics and Gynecology, Sant'Orsola Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - E Montaguti
- Department of Obstetrics and Gynecology, Sant'Orsola Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - G Di Donna
- Department of Obstetrics and Gynecology, Sant'Orsola Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - M G Dodaro
- Department of Obstetrics and Gynecology, Sant'Orsola Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - L Bianchini
- Department of Obstetrics and Gynecology, Sant'Orsola Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - G Pilu
- Department of Obstetrics and Gynecology, Sant'Orsola Malpighi University Hospital, University of Bologna, Bologna, Italy
| |
Collapse
|
21
|
Fetal molding examined with transperineal ultrasound and associations with position and delivery mode. Am J Obstet Gynecol 2020; 223:909.e1-909.e8. [PMID: 32585224 DOI: 10.1016/j.ajog.2020.06.042] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 06/12/2020] [Accepted: 06/18/2020] [Indexed: 01/03/2023]
Abstract
BACKGROUND To accommodate passage through the birth canal, the fetal skull is compressed and reshaped, a phenomenon known as molding. The fetal skull bones are separated by membranous sutures that facilitate compression and overlap, resulting in a reduced diameter. This increases the probability of a successful vaginal delivery. Fetal position, presentation, station, and attitude can be examined with ultrasound, but fetal head molding has not been previously studied with ultrasound. OBJECTIVE This study aimed to describe ultrasound-assessed fetal head molding in a population of nulliparous women with slow progress in the second stage of labor and to study associations with fetal position and delivery mode. STUDY DESIGN This was a secondary analysis of a population comprising 150 nulliparous women with a single fetus in cephalic presentation, with slow progress in the active second stage with pushing. Women were eligible for the study when an operative intervention was considered by the clinician. Molding was examined in stored transperineal two-dimensional and three-dimensional acquisitions and differentiated into occipitoparietal molding along the lambdoidal sutures, frontoparietal molding along the coronal sutures, and parietoparietal molding at the sagittal suture (molding in the midline). Molding could not be classified if positions were unknown, and these cases were excluded. We measured the distance from the molding to the head midline, molding step, and overlap of skull bones and looked for associations with fetal position and delivery mode. The responsible clinicians were blinded to the ultrasound findings. RESULTS Six cases with unknown position were excluded, leaving 144 women in the study population. Fetal position was anterior in 117 cases, transverse in 12 cases, and posterior in 15 cases. Molding was observed in 79 of 144 (55%) fetuses. Molding was seen significantly more often in occiput anterior positions than in non-occiput anterior positions (69 of 117 [59%] vs 10 of 27 [37%]; P=.04). In occiput anterior positions, the molding was seen as occipitoparietal molding in 68 of 69 cases and as parietoparietal molding in 1 case with deflexed attitude. Molding was seen in 19 of 38 (50%) of occiput anterior positions ending with spontaneous delivery, 42 of 71(59%) ending with vacuum extraction, and in 7 of 8 (88%) with failed vacuum extraction (P=.13). In 4 fetuses with occiput posterior positions, parietoparietal molding was diagnosed, and successful vacuum extraction occurred in 3 cases and failed extraction in 1. Frontoparietal molding was seen in 2 transverse positions and 4 posterior positions. One delivered spontaneously; vacuum extraction failed in 3 cases and was successful in 2. Only 1 of 11 fetuses with either parietoparietal or frontoparietal molding was delivered spontaneously. CONCLUSION The different types of molding can be classified with ultrasound. Occipitoparietal molding was commonly seen in occiput anterior positions and not significantly associated with delivery mode. Frontoparietal and parietoparietal moldings were less frequent than reported in old studies and should be studied in larger populations with mixed ethnicities.
Collapse
|
22
|
Intrapartum ultrasound at the initiation of the active second stage of labor predicts spontaneous vaginal delivery. Am J Obstet Gynecol MFM 2020; 3:100249. [PMID: 33451615 DOI: 10.1016/j.ajogmf.2020.100249] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Accepted: 09/26/2020] [Indexed: 12/27/2022]
Abstract
BACKGROUND Longer duration of active pushing during labor is associated with a higher rate of operative delivery and an increased risk of maternal and neonatal complications. Although immediate pushing at complete dilatation is associated with lower rates of chorioamnionitis and postpartum hemorrhage, it is also associated with a longer duration of pushing. OBJECTIVE This study aimed to evaluate whether fetal head station and position, as assessed by ultrasound at the beginning of the pushing process, can predict the mode of delivery and duration of pushing in nulliparous women. STUDY DESIGN This prospective observational study included nulliparous women with neuraxial analgesia and complete cervical dilatation. The following sonographic parameters were assessed just before the beginning of the pushing process, at rest, and while pushing during contraction: head position, angle of progression, head-perineum distance, and head-symphysis distance. The change between rest and pushing was designated as delta angle of progression, delta head-perineum distance, and delta head-symphysis distance. The sonographic measurements and fetal head station assessed by vaginal examination were compared between women who had a spontaneous vaginal delivery to those who underwent an operative delivery, and between those who pushed for more or less than 1 hour. RESULTS Of the 197 women included in this study, 166 (84.3%) had a spontaneous vaginal delivery, 31 (15.7%) had an operative delivery, 23 (11.6%) had a vacuum delivery, and 8 (4.0%) had a cesarean delivery. Spontaneous vaginal delivery and shorter duration of pushing (less than an hour) were significantly more common with a nonocciput posterior position (10.6% vs 47.3%; P<.005), a wider angle of progression, a shorter head-perineum distance and head-symphysis distance (both during rest and while pushing), and a lower fetal head station as assessed by digital vaginal examination. However, a logistic regression model revealed that only the angle of progression at rest and the delta angle of progression were independently associated with a spontaneous vaginal delivery with an area under the curve of 0.82 (95% confidence interval, 0.76-0.87; P<.0001) and 0.75 (95% confidence interval, 0.67-0.79; P<.0001), respectively. CONCLUSION Ultrasound performed at the beginning of the active second stage of labor can assist in predicting the mode of delivery and duration of pushing and perform better than the traditional digital examination, with the angle of progression at rest and delta angle of progression being the best predictors.
Collapse
|
23
|
Angeli L, Conversano F, Dall'Asta A, Volpe N, Simone M, Di Pasquo E, Pignatelli D, Schera GBL, Di Paola M, Ricciardi P, Ferretti A, Frusca T, Casciaro S, Ghi T. New technique for automatic sonographic measurement of change in head-perineum distance and angle of progression during active phase of second stage of labor. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 56:597-602. [PMID: 31909525 DOI: 10.1002/uog.21963] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 12/27/2019] [Accepted: 12/29/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVE To evaluate the performance of a new ultrasound technique for the automatic assessment of the change in head-perineum distance (delta-HPD) and angle of progression (delta-AoP) during the active phase of the second stage of labor. METHODS This was a prospective observational cohort study including singleton term pregnancies with fetuses in cephalic presentation during the active phase of the second stage of labor. In each patient, two videoclips of 10 s each were acquired transperineally, one in the axial and one in the sagittal plane, between rest and the acme of an expulsive effort, in order to measure HPD and AoP, respectively. The videoclips were processed offline and the difference between the acme of the pushing effort and rest in HPD (delta-HPD) and AoP (delta-AoP) was calculated, first manually by an experienced sonographer and then using a new automatic technique. The reliability of the automatic algorithm was evaluated by comparing the automatic measurements with those obtained manually, which was considered as the reference gold standard. RESULTS Overall, 27 women were included. A significant correlation was observed between the measurements obtained by the automatic and the manual methods for both delta-HPD (intraclass correlation coefficient (ICC) = 0.97) and delta-AoP (ICC = 0.99). The high accuracy provided by the automatic algorithm was confirmed by the high values of the coefficient of determination (r2 = 0.98 for both delta-HPD and delta-AoP) and the low residual errors (root mean square error = 1.2 mm for delta-HPD and 1.5° for delta-AoP). A Bland-Altman analysis showed a mean difference of 0.52 mm (limits of agreement, -1.58 to 2.62 mm) for delta-HPD (P = 0.034) and 0.35° (limits of agreement, -2.54 to 3.09°) for delta-AoP (P = 0.39) between the manual and automatic measurements. CONCLUSIONS The automatic assessment of delta-AoP and delta-HPD during maternal pushing efforts is feasible. The automatic measurement of delta-AoP appears to be reliable when compared with the gold standard manual measurement by an experienced operator. Copyright © 2020 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- L Angeli
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - F Conversano
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - A Dall'Asta
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - N Volpe
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | | | - E Di Pasquo
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - D Pignatelli
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - G B L Schera
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - M Di Paola
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - P Ricciardi
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - A Ferretti
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - T Frusca
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - S Casciaro
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - T Ghi
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| |
Collapse
|
24
|
Angeli L, Conversano F, Dall'Asta A, Eggebø T, Volpe N, Marta S, Pisani P, Casciaro S, Di Paola M, Frusca T, Ghi T. Automatic measurement of head-perineum distance during intrapartum ultrasound: description of the technique and preliminary results. J Matern Fetal Neonatal Med 2020; 35:2759-2764. [PMID: 32727248 DOI: 10.1080/14767058.2020.1799974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To evaluate the accuracy and reliability of a new ultrasound technique for the automatic assessment of the head-perineum distance (HPD) during childbirth. METHODS HPD was measured on a total of 40 acquisition sessions in 30 laboring women both automatically by an innovative algorithm and manually by trained sonographers, assumed as gold standard. RESULTS A significant correlation was found between manual and automatic measurements (Intra-CC = 0.994). High values of the coefficient of determination (r2=0.98) and low residual errors: RMSE = 2.01 mm (4.9%) were found. CONCLUSION The automatic algorithm for the assessment of the HPD represents a reliable technique.
Collapse
Affiliation(s)
- Laura Angeli
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| | | | - Andrea Dall'Asta
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| | - Torbjørn Eggebø
- National Center for Fetal Medicine, Trondheim University Hospital (St. Olavs Hospital), Trondheim, Norway.,Department of Laboratory Medicine, Children's and Women's Health, Norwegian University of Science and Technology, Trondheim, Norway
| | - Nicola Volpe
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| | | | - Paola Pisani
- Institute of Clinical Physiology, National Council Research, Lecce, Italy
| | - Sergio Casciaro
- Institute of Clinical Physiology, National Council Research, Lecce, Italy
| | - Marco Di Paola
- Institute of Clinical Physiology, National Council Research, Lecce, Italy
| | - Tiziana Frusca
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| | - Tullio Ghi
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| |
Collapse
|
25
|
García-Mejido JA, Martín-Martínez A, González-Diaz E, Fernández-Fernández C, Ortega I, Medina M, Fernández-Corona A, Fernández-Palacín A, Sainz JA. Malmström vacuum or Kielland forceps: which causes more damage to pelvic floor? ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 55:257-263. [PMID: 31332857 DOI: 10.1002/uog.20404] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2019] [Revised: 07/01/2019] [Accepted: 07/03/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVE To determine whether differences exist in the rate of levator ani muscle (LAM) avulsion between women who had undergone either Malmström vacuum delivery (MVD) or Kielland forceps delivery (KFD), allowing for potential confounding factors. METHODS This was a prospective observational study of nulliparous women undergoing instrumental delivery using Malmström vacuum extractor or Kielland forceps, at two hospital centers in Spain. Fetal head position (anterior, posterior or transverse) and fetal head station (low or mid) were assessed by ultrasound and digital examination, respectively. Avulsion was defined on tomographic ultrasound imaging as an abnormal insertion of the LAM in the three central slices from the plane of minimal hiatal dimensions. RESULTS In total, 414 patients were included in the study (212 MVD and 202 KFD). We observed a higher rate of LAM avulsion in the KFD group (KFD 49.5% vs MVD 32.5%; P = 0.001). When the results were evaluated according to fetal head position and station, we observed no differences in LAM avulsion. The crude odds ratio (OR) for the difference in avulsion between women in the KFD and MVD groups was 2.03 (95% CI, 1.36-3.03). However, when adjusted for duration of second stage of labor, fetal head circumference and fetal head station, the OR was no longer statistically significant (OR, 2.14 (95% CI, 0.95-4.85); P = 0.068). CONCLUSION When potential confounding factors are taken into account, the rate of LAM avulsion does not differ between women according to whether they have undergone KFD or MVD. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- J A García-Mejido
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain
- Department of Obstetrics and Gynecology, University of Seville, Seville, Spain
| | - A Martín-Martínez
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Gran Canarias, Gran Canarias, Spain
| | - E González-Diaz
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Leon (CAULE), Leon, Spain
| | - C Fernández-Fernández
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Leon (CAULE), Leon, Spain
| | - I Ortega
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Gran Canarias, Gran Canarias, Spain
| | - M Medina
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Gran Canarias, Gran Canarias, Spain
| | - A Fernández-Corona
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Leon (CAULE), Leon, Spain
| | - A Fernández-Palacín
- Biostatistics Unit, Department of Preventive Medicine and Public Health, University of Seville, Seville, Spain
| | - J A Sainz
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain
- Department of Obstetrics and Gynecology, University of Seville, Seville, Spain
| |
Collapse
|
26
|
Dall’Asta A, Angeli L, Masturzo B, Volpe N, Schera GBL, Di Pasquo E, Girlando F, Attini R, Menato G, Frusca T, Ghi T. Prediction of spontaneous vaginal delivery in nulliparous women with a prolonged second stage of labor: the value of intrapartum ultrasound. Am J Obstet Gynecol 2019; 221:642.e1-642.e13. [PMID: 31589867 DOI: 10.1016/j.ajog.2019.09.045] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 09/22/2019] [Accepted: 09/25/2019] [Indexed: 12/23/2022]
Abstract
BACKGROUND A limited number of studies have addressed the role of intrapartum ultrasound in the prediction of the mode of delivery in women with prolonged second stage of labor. OBJECTIVE The objective of the study was to evaluate the role of transabdominal and transperineal sonographic findings in the prediction of spontaneous vaginal delivery among nulliparous women with prolonged second stage of labor. STUDY DESIGN This was a 2-center prospective study conducted at 2 tertiary maternity units. Nulliparous women with a prolonged active second stage of labor, as defined by active pushing lasting more than 120 minutes, were eligible for inclusion. Transabdominal ultrasound to evaluate the fetal head position and transperineal ultrasound for the measurement of the midline angle, the head-perineum distance, and the head-symphysis distance were performed in between uterine contractions and maternal pushes. At transperineal ultrasound the angle of progression was measured at rest and at the peak of maternal pushing effort. The delta angle of progression was defined as the difference between the angle of progression measured during active pushing at the peak of maternal effort and the angle of progression at rest. The sonographic findings of women who had spontaneous vaginal delivery vs those who required obstetric intervention, either vacuum extraction or cesarean delivery, were evaluated and compared. RESULTS Overall, 109 were women included. Spontaneous vaginal delivery and obstetric intervention were recorded in 40 (36.7%) and 69 (63.3%) patients, respectively. Spontaneous vaginal delivery was associated with a higher rate of occiput anterior position (90% vs 53.2%, P < .0001), lower head-perineum distance and head-symphysis distance (33.2 ± 7.8 mm vs 40.1 ± 9.5 mm, P = .001, and 13.1 ± 4.6 mm vs 19.5 ± 8.4 mm, P < .001, respectively), narrower midline angle (29.6° ± 15.3° vs 54.2° ± 23.6°, P < .001) and wider angle of progression at the acme of the pushing effort (153.3° ± 19.8° vs 141.8° ± 25.7°, P = .02) and delta-angle of progression (17.3° ± 12.9° vs 12.5° ± 11.0°, P = .04). At logistic regression analysis, only the midline angle and the head-symphysis distance proved to be independent predictors of spontaneous vaginal delivery. More specifically, the area under the curve for the prediction of spontaneous vaginal delivery was 0.80, 95% confidence interval (0.69-0.92), P < .001, and 0.74, 95% confidence interval (0.65-0.83), P = .002, for the midline angle and for the head-symphysis distance, respectively. CONCLUSION Transabdominal and transperineal intrapartum ultrasound parameters can predict the likelihood of spontaneous vaginal delivery in nulliparous women with prolonged second stage of labor.
Collapse
|
27
|
Tse WT, Chaemsaithong P, Chan WW, Kwan AH, Huang J, Appiah K, Chong KC, Poon LC. Labor progress determined by ultrasound is different in women requiring cesarean delivery from those who experience a vaginal delivery following induction of labor. Am J Obstet Gynecol 2019; 221:335.e1-335.e18. [PMID: 31153931 DOI: 10.1016/j.ajog.2019.05.040] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 05/22/2019] [Accepted: 05/24/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND The diagnosis of labor dystocia generally is determined by the deviation of labor progress, which is assessed by the use of a partogram. Recently, intrapartum transperineal ultrasound for the assessment of fetal head descent has been introduced to assess labor progress in the first stage of labor in a more objective and noninvasive way. OBJECTIVE The objective of the study was to determine the differences in labor progress by the use of serial transperineal ultrasound assessment of fetal head descent between women having vaginal and cesarean delivery. STUDY DESIGN This was a prospective longitudinal study performed in 315 women with singleton pregnancy who were undergoing labor induction at term between December 2016 and December 2017. Paired assessment of cervical dilation and fetal head station by vaginal examination and transperineal ultrasonographic assessment of parasagittal angle of progression and head-perineum distance were made serially after the commencement of labor induction. According to the hospital protocol, assessment was performed every 24 hours and 4 hours, respectively, during latent and active phases of labor. The researchers and the clinical team were blinded to each other's findings. The repeated measures data were analyzed by mixed effect models. To determine the effect of mode of delivery on the association between parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation, the significance of the interaction term between each mode of delivery and fetal head station or cervical dilation was determined, which accounted for parity and obesity. Area under receiver-operating characteristic curve was used to evaluate the performance of serial intrapartum sonography in predicting women with cesarean delivery because of failure to progress. RESULTS The total number of paired vaginal examination and ultrasound assessments was 1198, with a median of 3 per woman. The median assessment-to-assessment interval was 4.6 hours (interquartile range, 4.3-5.1 hours). Women who achieved vaginal delivery (n=261) had steeper slopes of parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation than those who achieved cesarean delivery (n=54). Objectively, an additional decrease of 5.11 and 1.37 degrees in parasagittal angle of progression was observed for an unit increase in fetal head station and cervical dilation, respectively, in women who required cesarean delivery (P<.01; P=.01), compared with women who achieved vaginal delivery, after taking account of repeated measures from individuals and confounding factors. The respective additional increases in head-perineum distance for a unit increase in fetal head station and cervical dilation were 0.27 cm (P<.01) and 0.12 cm (P<.01). A combination of maternal characteristics with the temporal changes of parasagittal angle of progression for an unit increase in fetal head station achieved an area under receiver-operating characteristic curve of 0.85 (95% confidence interval, 0.76-0.94), with sensitivity of 79% and specificity of 80%, for the prediction of women who required cesarean delivery because of failure to progress. CONCLUSION The differences in labor progress between vaginal and cesarean delivery have been illustrated objectively by serial intrapartum transperineal ultrasonographic assessment of fetal head descent. This tool is potentially predictive of women who will require cesarean delivery because of failure to progress.
Collapse
|
28
|
Sainz JA, Martín-Martínez A, González-Diaz E, Fernández-Fernández C, Ortega I, Medina M, Fernández-Corona A, Fernández-Palacín A, García-Mejido JA. Influence of the disengagement of the forceps on levator ani muscle injuries in instrumental delivery: A multicenter study. Acta Obstet Gynecol Scand 2019; 98:1413-1419. [PMID: 31243757 DOI: 10.1111/aogs.13682] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2019] [Revised: 06/12/2019] [Accepted: 06/18/2019] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Forceps use is the main risk factor for levator ani muscle (LAM) injuries. We believe that the disengagement of the forceps branches before delivery of the fetal head could influence LAM injuries, so we aimed to determine the influence of the disengagement of the forceps on the occurrence of LAM avulsion during forceps delivery. MATERIAL AND METHODS A prospective, observational, multicenter study was conducted with 261 women who underwent forceps delivery. The women were classified according to whether the branches of the forceps had been disengaged before delivery of the fetal head. LAM avulsion was defined using a multislice mode (3 central slices). RESULTS In all, 255 women completed the study (160 without disengagement and 95 with disengagement). LAM avulsions were observed in 37.9% of women in the group with disengagement and in 41.9% of women in the group without disengagement. The crude OR (without disengagement vs with disengagement) for avulsion was 0.90 (95% CI 0.49-1.67, P = 0.757) and an adjusted OR of 0.82 (95% CI 0.40-1.69, P = 0.603). CONCLUSIONS We did not observe a statistically significant reduction in the LAM avulsion rate with disengagement of the forceps branches before delivery of the fetal head.
Collapse
Affiliation(s)
- José Antonio Sainz
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain.,Department of Obstetrics and Gynecology, University of Seville, Seville, Spain
| | - Alicia Martín-Martínez
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Gran Canarias, Gran Canarias, Spain
| | - Enrique González-Diaz
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Leon (CAULE), Leon, Spain
| | - Camino Fernández-Fernández
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Leon (CAULE), Leon, Spain
| | - Ismael Ortega
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Gran Canarias, Gran Canarias, Spain
| | - Margarita Medina
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Gran Canarias, Gran Canarias, Spain
| | - Alfonso Fernández-Corona
- Department of Obstetrics and Gynecology, Complejo Asistencial Universitario de Leon (CAULE), Leon, Spain
| | - Ana Fernández-Palacín
- Biostatistics Unit, Department of Preventive Medicine and Public Health, University of Seville, Seville, Spain
| | - José Antonio García-Mejido
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain.,Department of Obstetrics and Gynecology, University of Seville, Seville, Spain
| |
Collapse
|
29
|
Chaemsaithong P, Kwan AH, Tse WT, Lim WT, Chan WW, Chong KC, Leung TY, Poon LC. Factors that affect ultrasound-determined labor progress in women undergoing induction of labor. Am J Obstet Gynecol 2019; 220:592.e1-592.e15. [PMID: 30735668 DOI: 10.1016/j.ajog.2019.01.236] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 01/27/2019] [Accepted: 01/30/2019] [Indexed: 11/26/2022]
Abstract
BACKGROUND The traditional approach to the assessment of labor progress is by digital vaginal examination; however, it is subjective and imprecise. Recent studies have investigated the role of transperineal ultrasonographic assessment of fetal head descent by measuring the angle of progression and head-perineum distance. OBJECTIVE The objective of this study was to evaluate factors that affected labor progress, which were defined by the transperineal ultrasonographic parameters, in women who achieved vaginal delivery. STUDY DESIGN This was a prospective longitudinal study performed in 315 women with singleton pregnancy who underwent labor induction at term between December 2016 and December 2017. Paired assessment of cervical dilation and fetal head station by vaginal examination and transperineal ultrasonographic assessment of fetal head descent (parasagittal angle of progression and head-perineum distance) were made serially after the commencement of labor induction until full cervical dilation. The researchers were blinded to the findings of the clinical team's vaginal examination and vice versa. The repeated measure data were analyzed by mixed effect models to identify the significant factors (age ≥35 years, obesity, parity, methods of labor induction, and epidural anesthesia) that affected the relationship between parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation. RESULTS The total number of paired vaginal examination and transperineal ultrasonographic assessments among the 261 women (82.9%) with vaginal delivery was 945, with a median of 3 per woman. The median assessment-to-assessment interval was 4.6 hours (interquartile range, 4.3-5.2). Multiparity and mechanical methods of labor induction were associated with a faster rate of fetal head descent, which was determined by head-perineum distance against fetal head station, than nulliparity and the use of a slow-release vaginal pessary, respectively. An additional increase of 0.10 cm in head-perineum distance was observed, for an unit increase in fetal head station in nulliparous women (P=.03) and women who had a slow-release vaginal pessary (P=.02), compared with multiparous women and those who had mechanical methods for labor induction. The use of epidural anesthesia was associated with a slower rate of fetal head descent, which was determined by both parasagittal angle of progression and head-perineum distance, against fetal head station. An additional decrease of 3.66 degrees in parasagittal angle of progression (P=.04) and an additional increase in 0.33 cm in head-perineum distance (P≤.001) were observed for a unit increase in fetal head station in women with the use of epidural anesthesia, compared with those without. Obese women had higher head-perineum distance overall, compared with normal weight women; at different cross-sections of time periods, obesity appeared to be associated with a slower rate of change between head-perineum distance and cervical dilation. Advanced maternal age did not affect transperineal ultrasound-determined labor progress (P>.05). CONCLUSION Parity, methods of labor induction, the use of epidural anesthesia, and obesity affect labor progress, which has been illustrated objectively by serial transperineal ultrasonographic assessment of fetal head descent.
Collapse
|