Saengsin K, Pickard SS, Prakash A. Utility of cardiac CT in infants with congenital heart disease: Diagnostic performance and impact on management.
J Cardiovasc Comput Tomogr 2021;
16:345-349. [PMID:
34949532 DOI:
10.1016/j.jcct.2021.12.004]
[Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Revised: 10/24/2021] [Accepted: 12/13/2021] [Indexed: 01/17/2023]
Abstract
BACKGROUND
Advances in cardiac CT (CCT) scanner technology allow imaging without anesthesia, and with low radiation dose, making it an attractive technique in infants with congenital heart disease. However, the utility of CCT using a dual-source scanner with respect to diagnostic performance and impact on management has not been systematically studied in this population.
METHODS
Retrospective review of infants who underwent CCT to determine the utility of CCT with respect to the following: answering the primary diagnostic question, providing new diagnostic information, prompting a change in management, and concordance with catheterization or surgical inspection.
RESULTS
A total of 156 infants underwent 172 scans at a median age of 64 days, (IQR 4-188) from Jan 2016-Dec 2019. The most frequent diagnostic question was related to the pulmonary arteries (43%), followed by the aortic arch (30%), pulmonary veins (26%), coronary arteries (17%), patent ductus arteriosus (10%) and others (9%). A high-pitch spiral scan was frequently used (90%). The median effective radiation dose was low (0.66 mSv) and general anesthesia was used infrequently (23%). CCT answered the primary diagnostic question in 168/172 (98%) and added to the diagnostic information already available by echocardiography in 161/172 (96%) scans. CCT led to a change in management following 78/172 (53%) scans and had an impact on management following 167/172 (97%) scans. On follow-up, after 107/172 (62%) scans, subjects underwent cardiac surgery, and after 55/172 (32%) scans, they had cardiac catheterization. CCT findings were concordant with catheterization and/or surgical inspection in 156/159 (98%) scans.
CONCLUSIONS
In infants with complex congenital heart disease, CCT was accurate, answered the diagnostic questions in nearly all cases, and frequently added diagnostic information that impacted management. Radiation exposure was low, and anesthesia was needed infrequently.
Collapse