1
|
Chow MR, Fernandez Brillet C, Hageman KN, Roberts DC, Ayiotis AI, Haque RM, Della Santina CC. Binocular 3-D otolith-ocular reflexes: responses of chinchillas to natural and prosthetic stimulation after ototoxic injury and vestibular implantation. J Neurophysiol 2023; 129:1157-1176. [PMID: 37018758 PMCID: PMC10151050 DOI: 10.1152/jn.00445.2022] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 03/29/2023] [Accepted: 03/29/2023] [Indexed: 04/07/2023] Open
Abstract
The otolith end organs inform the brain about gravitational and linear accelerations, driving the otolith-ocular reflex (OOR) to stabilize the eyes during translational motion (e.g., moving forward without rotating) and head tilt with respect to gravity. We previously characterized OOR responses of normal chinchillas to whole body tilt and translation and to prosthetic electrical stimulation targeting the utricle and saccule via electrodes implanted in otherwise normal ears. Here we extend that work to examine OOR responses to tilt and translation stimuli after unilateral intratympanic gentamicin injection and to natural/mechanical and prosthetic/electrical stimulation delivered separately or in combination to animals with bilateral vestibular hypofunction after right ear intratympanic gentamicin injection followed by surgical disruption of the left labyrinth at the time of electrode implantation. Unilateral intratympanic gentamicin injection decreased natural OOR response magnitude to about half of normal, without markedly changing OOR response direction or symmetry. Subsequent surgical disruption of the contralateral labyrinth at the time of electrode implantation surgery further decreased OOR magnitude during natural stimulation, consistent with bimodal-bilateral otolith end organ hypofunction (ototoxic on the right ear, surgical on the left ear). Delivery of pulse frequency- or pulse amplitude-modulated prosthetic/electrical stimulation targeting the left utricle and saccule in phase with whole body tilt and translation motion stimuli yielded responses closer to normal than the deficient OOR responses of those same animals in response to head tilt and translation alone.NEW & NOTEWORTHY Previous studies to expand the scope of prosthetic stimulation of the otolith end organs showed that selective stimulation of the utricle and saccule is possible. This article further defines those possibilities by characterizing a diseased animal model and subsequently studying its responses to electrical stimulation alone and in combination with mechanical motion. We show that we can partially restore responses to tilt and translation in animals with unilateral gentamicin ototoxic injury and contralateral surgical disruption.
Collapse
Affiliation(s)
- Margaret R Chow
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, United States
| | - Celia Fernandez Brillet
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, United States
| | - Kristin N Hageman
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, United States
| | - Dale C Roberts
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins School of Medicine, Baltimore, Maryland, United States
| | - Andrianna I Ayiotis
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, United States
| | - Razi M Haque
- Lawrence Livermore National Laboratory, Livermore, California, United States
| | - Charles C Della Santina
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, United States
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins School of Medicine, Baltimore, Maryland, United States
| |
Collapse
|
2
|
Shigeno K. Subjective visual vertical deviation in patients with early-onset direction-changing horizontal positional nystagmus. Auris Nasus Larynx 2023; 50:48-56. [PMID: 35589462 DOI: 10.1016/j.anl.2022.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Revised: 04/21/2022] [Accepted: 05/06/2022] [Indexed: 01/28/2023]
Abstract
OBJECTIVE Otolithic dysfunction is investigated in cases of direction-changing horizontal positional nystagmus (DCHPN) due to peripheral vestibular disorders. METHODS The static-subjective visual vertical (S-SVV) was conducted in DCHPN cases within 48 h after onset. RESULTS The absolute values of S-SVV deviations of patients with Light cupula and lateral canal-benign paroxysmal positional vertigo-cupulolithiasis (L-BPPV-Cup) were significantly different from those of healthy subjects (p < 0.001, p < 0.05, respectively), whereas there were no significant differences in those of patients with L-BPPV-Canalolithiasis-geotropic (L-BPPV-Can-g) or L-BPPV-Can-ageotropic (L-BPPV-Can-a) versus healthy subjects. Significant differences were found in S-SVV (+: deviation to the affected side, -: deviation to the unaffected side) between patients with Light cupula and those with L-BPPV-Can-g, L-BPPV-Can-a and L-BPPV-Cup (p < 0.01, p < 0.05, and p < 0.001, respectively), as well as between those with L-BPPV-Can-g and L-BPPV-Cup (p < 0.01). The S-SVV in patients with Light cupula, L-BPPV-Can-g, and L-BPPV-Can-a deviated more to the affected side, whereas that in patients with L-BPPV-Cup deviated more to the unaffected side. CONCLUSION Mild otolithic dysfunctions were found in patients with DCHPN due to the presence of peripheral vestibular disorders within 48 h after onset. The extent of otolithic (utricular) disorders in patients with DCHPN is estimated in decreasing order as follows: Light cupula > L-BPPV-Cup > L-BPPV-Can-g and L-BPPV-Can-a. Many patients with L-BPPV-Cup likely suffer from disorders of the pars externa of the utricular macula, whereas many patients with L-BPPV-Can-g likely suffer from disorders of the pars interna of the utricular macula. L-BPPV-Can-a and L-BPPV-Can-g must be induced by a common mild utricular disorder.
Collapse
Affiliation(s)
- Kohichiro Shigeno
- Shigeno Otolaryngology Vertigo-Hearing Impairment Clinic, 1-21 Ougi-machi, Nagasaki 852-8132, Japan.
| |
Collapse
|
3
|
Discordant horizontal-torsional nystagmus: a sign of posterior semicircular canal dysfunction. J Neurol 2022; 269:5038-5046. [PMID: 35543743 DOI: 10.1007/s00415-022-11155-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 04/21/2022] [Accepted: 04/22/2022] [Indexed: 10/18/2022]
Abstract
In central as well as peripheral vestibular lesions, right-beating horizontal nystagmus is almost always associated with clockwise (top poles of the eyes beating to the right ear) torsional nystagmus when observed and vice versa (concordant nystagmus). This study aimed to determine the etiologies and mechanisms of horizontal and torsional nystagmus beating in the opposite directions (discordant nystagmus). We reviewed the medical records of 16 consecutive patients with discordant horizontal-torsional nystagmus who had been evaluated at the dizziness clinics of Seoul National University Bundang Hospital (n = 11, from March 2003 to March 2021) and Korea University Medical Center (n = 5, from March 2019 to March 2021). The underlying etiologies included inferior vestibular neuritis (n = 7), Meniere's disease (n = 4), internuclear ophthalmoplegia (n = 3), medullary hemorrhage (n = 1), and normal pressure hydrocephalus (n = 1). The torsional nystagmus decreased during the gaze in the same direction (for instance, during rightward gaze in clockwise nystagmus) and increased during the gaze in the opposite direction. Head-impulse tests (HITs) were positive for the ipsilesional posterior canal (PC) in all 11 patients with unilateral peripheral vestibulopathy and two of the three patients with unilateral central vestibulopathy. Discordant horizontal-torsional nystagmus may be observed in peripheral as well as central lesions. Given the findings of HITs and modulation of spontaneous nystagmus during lateral gazes, discordant horizontal-torsional nystagmus may be ascribed to selective damage of the excitatory or inhibitory pathway from the PC that innervates the ipsilateral superior oblique and contralateral inferior rectus muscles.
Collapse
|
4
|
Kim EK, Pasquesi L, Steenerson KK, Otero-Millan J, Sharon JD. Vestibular Test Results in Patients With Horizontal Canal Benign Paroxysmal Positional Vertigo. Cureus 2022; 14:e21460. [PMID: 35223244 PMCID: PMC8860719 DOI: 10.7759/cureus.21460] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/20/2022] [Indexed: 12/05/2022] Open
Abstract
Introduction While the mechanism of posterior canal benign paroxysmal positional vertigo (BPPV) is widely accepted as canalolithiasis, the pathophysiology of horizontal canal BPPV remains controversial. We seek to analyze vestibular test results of patients with horizontal canal BPPV with ageotropic nystagmus (AHC) and geotropic nystagmus (GHC) in comparison to patients with posterior canal BPPV (PC) to better understand its pathophysiology. Methods In a retrospective chart review of adults with BPPV at a tertiary referral balance center, we reviewed the clinical characteristics and compared videonystagmography, caloric, rotary chair, subjective visual vertical (SVV)/ subjective visual horizontal (SVH), and vestibular evoked myogenic potential (VEMP) results between groups. Results We included 11 AHC and seven GHC patients and randomly selected 20 PC patients as the comparison group. All groups had a high rate of migraine and low rates of diabetes and head trauma, but no difference between groups. Ipsilateral caloric weakness was more prevalent in the GHC group compared to the PC group (p=0.02). One of two AHC patients and both GHC patients who had SVV/SVH testing had abnormal findings. The only AHC patient who had ocular VEMP testing had abnormal results. Additionally, we observed a significant downbeating component to nystagmus (4 deg/sec or greater) exclusively in the AHC group (5/10 patients, p=0.001). Conclusions Patients with AHC and GHC have unique vestibular testing results. In particular, only AHC patients showed a downbeating component to their nystagmus, which may suggest utricular dysfunction in the pathophysiology of AHC.
Collapse
|
5
|
Péus D, Straumann D, Huber A, Bockisch CJ, Wettstein V. Therapy-Resistant Atypical Downbeat Nystagmus with Vertigo Confined to Specific Head-Hanging Positions: Mapping to the Gravity Vector on a Multi-Axis Turntable. Case Rep Neurol 2021; 13:464-469. [PMID: 34413748 PMCID: PMC8339484 DOI: 10.1159/000517840] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Accepted: 06/03/2021] [Indexed: 12/21/2022] Open
Abstract
Downbeat nystagmus (DBN) observed in head-hanging positions, may be of central or peripheral origin. Central DBN in head-hanging positions is mostly due to a disorder of the vestibulo-cerebellum, whereas peripheral DBN is usually attributed to canalolithiasis of an anterior semicircular canal. Here, we describe an atypical case of a patient who, after head trauma, experienced severe and stereotypic vertigo attacks after being placed in various head-hanging positions. Vertigo lasted 10–15 s and was always associated with a robust DBN. The provocation of transient vertigo and DBN, which both showed no decrease upon repetition of maneuvers, depended on the yaw orientation relative to the trunk and the angle of backward pitch. On a motorized, multi-axis turntable, we identified the two-dimensional Helmholtz coordinates of head positions at which vertigo and DBN occurred (y-axis: horizontal, space-fixed; z-axis: vertical, and head-fixed; x-axis: torsional, head-fixed, and unchanged). This two-dimensional area of DBN-associated head positions did not change when whole-body rotations took different paths (e.g., by forwarding pitch) or were executed with different velocities. Moreover, the intensity of DBN was also independent of whole-body rotation paths and velocities. So far, therapeutic approaches with repeated liberation maneuvers and cranial vibrations were not successful. We speculate that vertigo and DBN in this patient are due to macular damage, possibly an unstable otolithic membrane that, in specific orientations relative to gravity, slips into a position causing paroxysmal stimulation or inhibition of macular hair cells.
Collapse
Affiliation(s)
- Dominik Péus
- Department of Otorhinolaryngology, Head and Neck Surgery, University of Zurich and University Hospital Zurich, Zurich, Switzerland.,Department of Neurology, University of Zurich and University Hospital Zurich, Zurich, Switzerland
| | - Dominik Straumann
- Department of Ophthalmology, University of Zurich and University Hospital Zurich, Zurich, Switzerland
| | - Alexander Huber
- Department of Otorhinolaryngology, Head and Neck Surgery, University of Zurich and University Hospital Zurich, Zurich, Switzerland
| | - Christopher J Bockisch
- Department of Otorhinolaryngology, Head and Neck Surgery, University of Zurich and University Hospital Zurich, Zurich, Switzerland.,Department of Ophthalmology, University of Zurich and University Hospital Zurich, Zurich, Switzerland
| | - Vincent Wettstein
- Department of Otorhinolaryngology, Head and Neck Surgery, University of Zurich and University Hospital Zurich, Zurich, Switzerland.,Rautipraxis AG, Zurich, Switzerland
| |
Collapse
|
6
|
Zhang Y, Soper J, Lohse CM, Eggers SDZ, Kaufman KR, McCaslin DL. Agreement between the Skull Vibration-Induced Nystagmus Test and Semicircular Canal and Otolith Asymmetry. J Am Acad Audiol 2021; 32:283-289. [PMID: 33873220 DOI: 10.1055/s-0041-1723039] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
BACKGROUND How significant asymmetries in otolith organ function in the presence of symmetrical and asymmetrical semicircular canal function influence skull vibration-induced nystagmus testing (SVINT) has not been well described. PURPOSE The aim of the study is to examine the agreement between SVINT and caloric testing, ocular vestibular-evoked myogenic potentials (oVEMP), and cervical vestibular-evoked myogenic potentials (cVEMP) for detecting asymmetric vestibular function. RESEARCH DESIGN This is a retrospective study of patients presenting with the chief complaint of vertigo, dizziness, or imbalance. STUDY SAMPLE A total of 812 patients were studied with a median age at testing of 59 years (interquartile range 46-70; range 18-93) and included 475 (59%) women. INTERVENTION Either the monothermal warm caloric test or alternate binaural bithermal caloric test, oVEMP, and cVEMP tests were administered to all patients. All patients underwent the SVINT prior to vestibular laboratory testing. DATA COLLECTION AND ANALYSIS Agreement between tests categorized as normal versus abnormal was summarized using percent concordance (PC). Sensitivity and specificity values were calculated for SVINT compared with other tests of vestibular function. RESULTS There was higher agreement between ipsilateral and contralateral SVINT with the caloric test (PC = 80% and 81%, respectively) compared with oVEMP (PC = 63% and 64%, respectively) and cVEMP (PC = 76% and 78%, respectively). Ipsilateral and contralateral SVINT showed higher sensitivity for the caloric test (sensitivity = 47% and 36%, respectively) compared with oVEMP (sensitivity = 26% and 21%, respectively), or cVEMP (sensitivity = 33% vs. 27%, respectively). Specificity of SVINT was high (>80%) for all assessments of vestibular function. CONCLUSION The presence of SVIN is a useful indicator of the asymmetry of vestibular function between the two ears when making judgments about semicircular canal asymmetry but is less sensitive to asymmetries in otolith organ function.
Collapse
Affiliation(s)
- Yue Zhang
- Vestibular and Balance Program, Department of Otorhinolaryngology, Mayo Clinic, Rochester, Minnesota.,Department of Rehabilitation Medicine, Tianjin Huanhu Hospital, Tianjin, China
| | - Jamie Soper
- MercyOne Waterloo Medical Center, ENT/Allergy Care, Waterloo, Iowa
| | - Christine M Lohse
- Division of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, Minnesota
| | - Scott D Z Eggers
- Vestibular and Balance Program, Department of Neurology, Mayo Clinic, Rochester, Minnesota
| | - Kenton R Kaufman
- Motion Analysis Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Devin L McCaslin
- Vestibular and Balance Program, Department of Otorhinolaryngology, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
7
|
Curthoys IS. The Anatomical and Physiological Basis of Clinical Tests of Otolith Function. A Tribute to Yoshio Uchino. Front Neurol 2020; 11:566895. [PMID: 33193004 PMCID: PMC7606994 DOI: 10.3389/fneur.2020.566895] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 09/18/2020] [Indexed: 12/15/2022] Open
Abstract
Otolithic receptors are stimulated by gravitoinertial force (GIF) acting on the otoconia resulting in deflections of the hair bundles of otolithic receptor hair cells. The GIF is the sum of gravitational force and the inertial force due to linear acceleration. The usual clinical and experimental tests of otolith function have used GIFs (roll tilts re gravity or linear accelerations) as test stimuli. However, the opposite polarization of receptors across each otolithic macula is puzzling since a GIF directed across the otolith macula will excite receptors on one side of the line of polarity reversal (LPR at the striola) and simultaneously act to silence receptors on the opposite side of the LPR. It would seem the two neural signals from the one otolith macula should cancel. In fact, Uchino showed that instead of canceling, the simultaneous stimulation of the oppositely polarized hair cells enhances the otolithic response to GIF—both in the saccular macula and the utricular macula. For the utricular system there is also commissural inhibitory interaction between the utricular maculae in each ear. The results are that the one GIF stimulus will cause direct excitation of utricular receptors in the activated sector in one ear as well as indirect excitation resulting from the disfacilitation of utricular receptors in the corresponding sector on the opposite labyrinth. There are effectively two complementary parallel otolithic afferent systems—the sustained system concerned with signaling low frequency GIF stimuli such as roll head tilts and the transient system which is activated by sound and vibration. Clinical tests of the sustained otolith system—such as ocular counterrolling to roll-tilt or tests using linear translation—do not show unilateral otolithic loss reliably, whereas tests of transient otolith function [vestibular evoked myogenic potentials (VEMPs) to brief sound and vibration stimuli] do show unilateral otolithic loss. The opposing sectors of the maculae also explain the results of galvanic vestibular stimulation (GVS) where bilateral mastoid galvanic stimulation causes ocular torsion position similar to the otolithic response to GIF. However, GVS stimulates canal afferents as well as otolithic afferents so the eye movement response is complex.
Collapse
Affiliation(s)
- Ian S Curthoys
- Vestibular Research Laboratory, School of Psychology, The University of Sydney, Sydney, NSW, Australia
| |
Collapse
|
8
|
Lee SU, Kim HJ, Choi JY, Kim JS. Ictal downbeat nystagmus in Ménière disease: A cross-sectional study. Neurology 2020; 95:e2409-e2417. [PMID: 32817190 DOI: 10.1212/wnl.0000000000010653] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Accepted: 05/21/2020] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To determine the mechanism of ictal downbeat nystagmus in Ménière disease (MD), we compared the head impulse gain of the vestibulo-ocular reflex (VOR) for each semicircular canal between patients with (n = 7) and without (n = 70) downbeat nystagmus during attacks of MD. METHODS We retrospectively analyzed the results of video-oculography, video head-impulse tests, and cervical vestibular-evoked myogenic potentials (VEMPs) in 77 patients with definite MD who were evaluated during an attack. RESULTS Pure or predominant downbeat nystagmus was observed in 7 patients (9%) with unilateral MD during the attacks. All 7 patients showed spontaneous downbeat nystagmus without visual fixation with a slow phase velocity ranging from 1.5 to 11.2°/s (median 5.4, interquartile range 3.7-8.5). All showed a transient decrease of the head impulse VOR gains for the posterior canals (PCs) in both ears (n = 4) or in the affected ear (n = 3). Cervical VEMPs were decreased in the affected (n = 2) or both ears (n = 2) when evaluated during the attacks. Downbeat nystagmus disappeared along with normalization of the VOR gains for PCs after the attacks in all patients. During the attacks, the head impulse VOR gains for the PC on the affected side were lower in the patients with ictal downbeat nystagmus than in those without (Mann-Whitney U test, p < 0.001), while the gains for other semicircular canals did not differ between the groups. CONCLUSION Downbeat nystagmus may be observed during attacks of MD due to an asymmetry in the vertical VOR or saccular dysfunction. MD should be considered in recurrent audiovestibulopathy and ictal downbeat nystagmus.
Collapse
Affiliation(s)
- Sun-Uk Lee
- From the Department of Neurology (S.-U.L.), Korea University Medical Center; Department of Neurology (S.-U.L., J.-Y.C., J.-S.K.), Seoul National University College of Medicine; and Research Administration Team (H.-J.K.) and Dizziness Center (J.-Y.C., J.-S.K.), Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Hyo-Jung Kim
- From the Department of Neurology (S.-U.L.), Korea University Medical Center; Department of Neurology (S.-U.L., J.-Y.C., J.-S.K.), Seoul National University College of Medicine; and Research Administration Team (H.-J.K.) and Dizziness Center (J.-Y.C., J.-S.K.), Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Jeong-Yoon Choi
- From the Department of Neurology (S.-U.L.), Korea University Medical Center; Department of Neurology (S.-U.L., J.-Y.C., J.-S.K.), Seoul National University College of Medicine; and Research Administration Team (H.-J.K.) and Dizziness Center (J.-Y.C., J.-S.K.), Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Ji-Soo Kim
- From the Department of Neurology (S.-U.L.), Korea University Medical Center; Department of Neurology (S.-U.L., J.-Y.C., J.-S.K.), Seoul National University College of Medicine; and Research Administration Team (H.-J.K.) and Dizziness Center (J.-Y.C., J.-S.K.), Seoul National University Bundang Hospital, Seongnam, South Korea.
| |
Collapse
|
9
|
Matos R, Navarro M, Pérez-Guillén V, Pérez-Garrigues H. The role of vertical semicircular canal function in the vertical component of skull vibration-induced nystagmus. Acta Otolaryngol 2020; 140:639-645. [PMID: 32329666 DOI: 10.1080/00016489.2020.1751877] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Background: Generally, vertical component of the skull vibratory nystagmus (VCN) is ignored in the clinical practise. Thus, the relative contribution of the vestibular organs in the presence of VCN remains unknown.Objectives: To determine the association between vertical semicircular canal (vSCC) function and the presence of VCN.Material and methods: Comparisons were made between Video Head Impulse Test and SVINT (100 Hz) results at the time of the acute peripheral vestibular lesion (PVL) and at the post-acute phase in patients diagnosed PVL. Later on, a paired analysis was performed restricting the assessments to patients with vestibular explorations in both the acute and post-acute phases.Results: In an univariable analysis, larger mean total gain differences (TGD) between vSCC VOR gains, significantly related with the appearance of VCN in nystagmography in the acute phase (p = .001), unlike the post-acute phase (p = .46). After a multivariate analysis, mean TGD was the only predictive factor of the VCN (p = .013). In the paired analysis, we found an increase in the post-acute phase mean TGD, approaching zero value.Conclusions and significance: Global relation between all vertical canals has at least a contributory role in the presence of the vertical component of nystagmus in SVINT.
Collapse
Affiliation(s)
- Ricardo Matos
- Department of Otorhinolaryngology, Centro Hospitalar Universitário São João EPE, Porto, Portugal University of Porto Medical School, Porto, Portugal.,University of Porto Medical School, Porto, Portugal
| | - Marta Navarro
- Otoneurology Unit, ENT Department, Hospital "La Fe", Valencia, Spain
| | | | | |
Collapse
|
10
|
Hageman KN, Chow MR, Roberts D, Boutros PJ, Tooker A, Lee K, Felix S, Pannu SS, Haque R, Della Santina CC. Binocular 3D otolith-ocular reflexes: responses of chinchillas to prosthetic electrical stimulation targeting the utricle and saccule. J Neurophysiol 2019; 123:259-276. [PMID: 31747349 DOI: 10.1152/jn.00883.2018] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
From animal experiments by Cohen and Suzuki et al. in the 1960s to the first-in-human clinical trials now in progress, prosthetic electrical stimulation targeting semicircular canal branches of the vestibular nerve has proven effective at driving directionally appropriate vestibulo-ocular reflex eye movements, postural responses, and perception. That work was considerably facilitated by the fact that all hair cells and primary afferent neurons in each canal have the same directional sensitivity to head rotation, the three canals' ampullary nerves are geometrically distinct from one another, and electrically evoked three-dimensional (3D) canal-ocular reflex responses approximate a simple vector sum of linearly independent components representing relative excitation of each of the three canals. In contrast, selective prosthetic stimulation of the utricle and saccule has been difficult to achieve, because hair cells and afferents with many different directional sensitivities are densely packed in those endorgans and the relationship between 3D otolith-ocular reflex responses and the natural and/or prosthetic stimuli that elicit them is more complex. As a result, controversy exists regarding whether selective, controllable stimulation of electrically evoked otolith-ocular reflexes (eeOOR) is possible. Using micromachined, planar arrays of electrodes implanted in the labyrinth, we quantified 3D, binocular eeOOR responses to prosthetic electrical stimulation targeting the utricle, saccule, and semicircular canals of alert chinchillas. Stimuli delivered via near-bipolar electrode pairs near the maculae elicited sustained ocular countertilt responses that grew reliably with pulse rate and pulse amplitude, varied in direction according to which stimulating electrode was employed, and exhibited temporal dynamics consistent with responses expected for isolated macular stimulation.NEW & NOTEWORTHY As the second in a pair of papers on Binocular 3D Otolith-Ocular Reflexes, this paper describes new planar electrode arrays and vestibular prosthesis architecture designed to target the three semicircular canals and the utricle and saccule. With this technological advancement, electrically evoked otolith-ocular reflexes due to stimulation via utricle- and saccule-targeted electrodes were recorded in chinchillas. Results demonstrate advances toward achieving selective stimulation of the utricle and saccule.
Collapse
Affiliation(s)
- Kristin N Hageman
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland
| | - Margaret R Chow
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland
| | - Dale Roberts
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins School of Medicine, Baltimore, Maryland
| | - Peter J Boutros
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland
| | - Angela Tooker
- Lawrence Livermore National Laboratory, Livermore, California
| | - Kye Lee
- Lawrence Livermore National Laboratory, Livermore, California
| | - Sarah Felix
- Lawrence Livermore National Laboratory, Livermore, California
| | | | - Razi Haque
- Lawrence Livermore National Laboratory, Livermore, California
| | - Charles C Della Santina
- Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland.,Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins School of Medicine, Baltimore, Maryland
| |
Collapse
|
11
|
Curthoys IS. Concepts and Physiological Aspects of the Otolith Organ in Relation to Electrical Stimulation. Audiol Neurootol 2019; 25:25-34. [PMID: 31553977 DOI: 10.1159/000502712] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Accepted: 08/13/2019] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND This paper discusses some of the concepts and major physiological issues in developing a means of electrically stimulating the otolithic system, with the final goal being the electrical stimulation of the otoliths in human patients. It contrasts the challenges of electrical stimulation of the otolith organs as compared to stimulation of the semicircular canals. Electrical stimulation may consist of trains of short-duration pulses (e.g., 0.1 ms duration at 400 Hz) by selective electrodes on otolith maculae or otolithic afferents, or unselective maintained DC stimulation by large surface electrodes on the mastoids - surface galvanic stimulation. SUMMARY Recent anatomical and physiological results are summarized in order to introduce some of the unique issues in electrical stimulation of the otoliths. The first challenge is that each otolithic macula contains receptors with opposite polarization (opposing preferred directions of stimulation), unlike the uniform polarization of receptors in each semicircular canal crista. The puzzle is that in response to the one linear acceleration in the one macula, some otolithic afferents have an increased activation whereas others have decreased activation. Key Messages: At the vestibular nucleus this opposite receptor hair cell polarization and consequent opposite afferent input allow enhanced response to the one linear acceleration, via a "push-pull" neural mechanism in a manner analogous to the enhancement of semicircular canal responses to angular acceleration. Within each otolithic macula there is not just one uniform otolithic neural input to the brain - there are very distinctly different channels of otolithic neural inputs transferring the neural data to the brainstem. As a simplification these channels are characterized as the sustained and transient systems. Afferents in each system have different responses to stimulus onset and maintained stimulation and likely different projections, and most importantly different thresholds for activation by electrical stimulation and different adaptation rates to maintained stimulation. The implications of these differences are considered.
Collapse
Affiliation(s)
- Ian S Curthoys
- Vestibular Research Laboratory, School of Psychology, University of Sydney, Sydney, New South Wales, Australia,
| |
Collapse
|
12
|
Sluydts M, Curthoys I, Vanspauwen R, Papsin BC, Cushing SL, Ramos A, Ramos de Miguel A, Borkoski Barreiro S, Barbara M, Manrique M, Zarowski A. Electrical Vestibular Stimulation in Humans: A Narrative Review. Audiol Neurootol 2019; 25:6-24. [PMID: 31533097 DOI: 10.1159/000502407] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Accepted: 07/29/2019] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND In patients with bilateral vestibulopathy, the regular treatment options, such as medication, surgery, and/or vestibular rehabilitation, do not always suffice. Therefore, the focus in this field of vestibular research shifted to electrical vestibular stimulation (EVS) and the development of a system capable of artificially restoring the vestibular function. Key Message: Currently, three approaches are being investigated: vestibular co-stimulation with a cochlear implant (CI), EVS with a vestibular implant (VI), and galvanic vestibular stimulation (GVS). All three applications show promising results but due to conceptual differences and the experimental state, a consensus on which application is the most ideal for which type of patient is still missing. SUMMARY Vestibular co-stimulation with a CI is based on "spread of excitation," which is a phenomenon that occurs when the currents from the CI spread to the surrounding structures and stimulate them. It has been shown that CI activation can indeed result in stimulation of the vestibular structures. Therefore, the question was raised whether vestibular co-stimulation can be functionally used in patients with bilateral vestibulopathy. A more direct vestibular stimulation method can be accomplished by implantation and activation of a VI. The concept of the VI is based on the technology and principles of the CI. Different VI prototypes are currently being evaluated regarding feasibility and functionality. So far, all of them were capable of activating different types of vestibular reflexes. A third stimulation method is GVS, which requires the use of surface electrodes instead of an implanted electrode array. However, as the currents are sent through the skull from one mastoid to the other, GVS is rather unspecific. It should be mentioned though, that the reported spread of excitation in both CI and VI use also seems to induce a more unspecific stimulation. Although all three applications of EVS were shown to be effective, it has yet to be defined which option is more desirable based on applicability and efficiency. It is possible and even likely that there is a place for all three approaches, given the diversity of the patient population who serves to gain from such technologies.
Collapse
Affiliation(s)
- Morgana Sluydts
- European Institute for Otorhinolaryngology, GZA Hospitals Antwerp, Wilrijk, Belgium,
| | - Ian Curthoys
- Vestibular Research Laboratory, University of Sydney, Sydney, New South Wales, Australia
| | - Robby Vanspauwen
- European Institute for Otorhinolaryngology, GZA Hospitals Antwerp, Wilrijk, Belgium
| | - Blake Croll Papsin
- Department of Otolaryngology - Head and Neck Surgery, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Sharon Lynn Cushing
- Department of Otolaryngology - Head and Neck Surgery, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Angel Ramos
- Hearing Loss Unit, Otorhinolaryngology, Head and Neck Department, Complejo Hospitalario Universitario Insular Materno Infantil, Las Palmas of Gran Canaria, Spain
| | - Angel Ramos de Miguel
- Hearing Loss Unit, Otorhinolaryngology, Head and Neck Department, Complejo Hospitalario Universitario Insular Materno Infantil, Las Palmas of Gran Canaria, Spain
| | - Silvia Borkoski Barreiro
- Hearing Loss Unit, Otorhinolaryngology, Head and Neck Department, Complejo Hospitalario Universitario Insular Materno Infantil, Las Palmas of Gran Canaria, Spain
| | | | - Manuel Manrique
- Otorhinolaryngology Department, Clinica Universidad de Navarra, Pamplona, Spain
| | - Andrzej Zarowski
- European Institute for Otorhinolaryngology, GZA Hospitals Antwerp, Wilrijk, Belgium
| |
Collapse
|
13
|
Virtual Rhesus Labyrinth Model Predicts Responses to Electrical Stimulation Delivered by a Vestibular Prosthesis. J Assoc Res Otolaryngol 2019; 20:313-339. [PMID: 31165284 DOI: 10.1007/s10162-019-00725-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Accepted: 05/08/2019] [Indexed: 10/26/2022] Open
Abstract
To better understand the spread of prosthetic current in the inner ear and to facilitate design of electrode arrays and stimulation protocols for a vestibular implant system intended to restore sensation after loss of vestibular hair cell function, we created a model of the primate labyrinth. Because the geometry of the implanted ear is complex, accurately modeling effects of prosthetic stimuli on vestibular afferent activity required a detailed representation of labyrinthine anatomy. Model geometry was therefore generated from three-dimensional (3D) reconstructions of a normal rhesus temporal bone imaged using micro-MRI and micro-CT. For systematically varied combinations of active and return electrode location, the extracellular potential field during a biphasic current pulse was computed using finite element methods. Potential field values served as inputs to stochastic, nonlinear dynamic models for each of 2415 vestibular afferent axons, each with unique origin on the neuroepithelium and spiking dynamics based on a modified Smith and Goldberg model. We tested the model by comparing predicted and actual 3D vestibulo-ocular reflex (VOR) responses for eye rotation elicited by prosthetic stimuli. The model was individualized for each implanted animal by placing model electrodes in the standard labyrinth geometry based on CT localization of actual implanted electrodes. Eye rotation 3D axes were predicted from relative proportions of model axons excited within each of the three ampullary nerves, and predictions were compared to archival eye movement response data measured in three alert rhesus monkeys using 3D scleral coil oculography. Multiple empirically observed features emerged as properties of the model, including effects of changing active and return electrode position. The model predicts improved prosthesis performance when the reference electrode is in the labyrinth's common crus (CC) rather than outside the temporal bone, especially if the reference electrode is inserted nearly to the junction of the CC with the vestibule. Extension of the model to human anatomy should facilitate optimal design of electrode arrays for clinical application.
Collapse
|
14
|
Hitier M, Sato G, Zhang YF, Zheng Y, Besnard S, Smith PF. Vestibular-related eye movements in the rat following selective electrical stimulation of the vestibular sensors. J Comp Physiol A Neuroethol Sens Neural Behav Physiol 2018; 204:835-847. [DOI: 10.1007/s00359-018-1286-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 08/29/2018] [Accepted: 09/04/2018] [Indexed: 01/26/2023]
|
15
|
Parameters of skull vibration-induced nystagmus in normal subjects. Eur Arch Otorhinolaryngol 2018; 275:1955-1961. [DOI: 10.1007/s00405-018-5020-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Accepted: 05/26/2018] [Indexed: 11/28/2022]
|
16
|
Ictal downbeat nystagmus in bilateral Meniere’s disease. J Neurol 2017; 264:2024-2026. [DOI: 10.1007/s00415-017-8589-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Revised: 08/04/2017] [Accepted: 08/07/2017] [Indexed: 10/19/2022]
|
17
|
Hitier M, Sato G, Zhang YF, Zheng Y, Besnard S, Smith PF, Curthoys IS. Anatomy and surgical approach of rat’s vestibular sensors and nerves. J Neurosci Methods 2016; 270:1-8. [DOI: 10.1016/j.jneumeth.2016.05.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 05/14/2016] [Accepted: 05/16/2016] [Indexed: 11/25/2022]
|
18
|
Lumbreras V, Bas E, Gupta C, Rajguru SM. Pulsed infrared radiation excites cultured neonatal spiral and vestibular ganglion neurons by modulating mitochondrial calcium cycling. J Neurophysiol 2014; 112:1246-55. [PMID: 24920028 DOI: 10.1152/jn.00253.2014] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Cochlear implants are currently the most effective solution for profound sensorineural hearing loss, and vestibular prostheses are under development to treat bilateral vestibulopathies. Electrical current spread in these neuroprostheses limits channel independence and, in some cases, may impair their performance. In comparison, optical stimuli that are spatially confined may result in a significant functional improvement. Pulsed infrared radiation (IR) has previously been shown to elicit responses in neurons. This study analyzes the response of neonatal rat spiral and vestibular ganglion neurons in vitro to IR (wavelength = 1,863 nm) using Ca(2+) imaging. Both types of neurons responded consistently with robust intracellular Ca(2+) ([Ca(2+)]i) transients that matched the low-frequency IR pulses applied (4 ms, 0.25-1 pps). Radiant exposures of ∼637 mJ/cm(2) resulted in continual neuronal activation. Temperature or [Ca(2+)] variations in the media did not alter the IR-evoked transients, ruling out extracellular Ca(2+) involvement or primary mediation by thermal effects on the plasma membrane. While blockage of Na(+), K(+), and Ca(2+) plasma membrane channels did not alter the IR-evoked response, blocking of mitochondrial Ca(2+) cycling with CGP-37157 or ruthenium red reversibly inhibited the IR-evoked [Ca(2+)]i transients. Additionally, the magnitude of the IR-evoked transients was dependent on ryanodine and cyclopiazonic acid-dependent Ca(2+) release. These results suggest that IR modulation of intracellular calcium cycling contributes to stimulation of spiral and vestibular ganglion neurons. As a whole, the results suggest selective excitation of neurons in the IR beam path and the potential of IR stimulation in future auditory and vestibular prostheses.
Collapse
Affiliation(s)
- Vicente Lumbreras
- Department of Biomedical Engineering, University of Miami, Miami, Florida; and
| | - Esperanza Bas
- Department of Otolaryngology, University of Miami, Miami, Florida
| | - Chhavi Gupta
- Department of Otolaryngology, University of Miami, Miami, Florida
| | - Suhrud M Rajguru
- Department of Biomedical Engineering, University of Miami, Miami, Florida; and Department of Otolaryngology, University of Miami, Miami, Florida
| |
Collapse
|
19
|
Abstract
AIM Postoperative vertigo is a well-known complication after cochlear implantation. The aim of the study was to investigate whether the electrical stimulation of the auditory structures via cochlear implant electrodes can affect the vestibular system and induce vertigo. MATERIALS AND METHODS In the first group, 114 patients were surveyed retrospectively via questionnaires to evaluate the occurrence and frequency of sound-induced vertigo after cochlear implantation. In the second group of 26 patients, the effects of electrical stimulation on the vestibular system were studied prospectively. RESULTS In the first group of patients without any preoperative sound-induced vertigo (n = 104), 20 patients (18%) reported sound-induced vertigo, which occurred after cochlear implantation. In the second group, an acoustic stimulus delivered via the speech processor of the cochlear implant elicited a vestibular evoked myogenic potential response in 4 of the 26 patients as a sign of vestibular costimulation (of the macula sacculi as part of the otolith organs). Horizontal and vertical nystagmus was triggered, whereas utricular function and postural stability remained unchanged. No correlation was found between C/M levels and the vestibular evoked myogenic potentials and nystagmus responses. CONCLUSION Sound-induced vertigo can occur in cochlear implantees. This seems to be primarily caused by electrical costimulation of the sacculus as part of the otolith organs.
Collapse
|
20
|
Lambert FM, Straka H. The frog vestibular system as a model for lesion-induced plasticity: basic neural principles and implications for posture control. Front Neurol 2012; 3:42. [PMID: 22518109 PMCID: PMC3324849 DOI: 10.3389/fneur.2012.00042] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2011] [Accepted: 03/05/2012] [Indexed: 11/13/2022] Open
Abstract
Studies of behavioral consequences after unilateral labyrinthectomy have a long tradition in the quest of determining rules and limitations of the central nervous system (CNS) to exert plastic changes that assist the recuperation from the loss of sensory inputs. Frogs were among the first animal models to illustrate general principles of regenerative capacity and reorganizational neural flexibility after a vestibular lesion. The continuous successful use of the latter animals is in part based on the easy access and identifiability of nerve branches to inner ear organs for surgical intervention, the possibility to employ whole brain preparations for in vitro studies and the limited degree of freedom of postural reflexes for quantification of behavioral impairments and subsequent improvements. Major discoveries that increased the knowledge of post-lesional reactive mechanisms in the CNS include alterations in vestibular commissural signal processing and activation of cooperative changes in excitatory and inhibitory inputs to disfacilitated neurons. Moreover, the observed increase of synaptic efficacy in propriospinal circuits illustrates the importance of limb proprioceptive inputs for postural recovery. Accumulated evidence suggests that the lesion-induced neural plasticity is not a goal-directed process that aims toward a meaningful restoration of vestibular reflexes but rather attempts a survival of those neurons that have lost their excitatory inputs. Accordingly, the reaction mechanism causes an improvement of some components but also a deterioration of other aspects as seen by spatio-temporally inappropriate vestibulo-motor responses, similar to the consequences of plasticity processes in various sensory systems and species. The generality of the findings indicate that frogs continue to form a highly amenable vertebrate model system for exploring molecular and physiological events during cellular and network reorganization after a loss of vestibular function.
Collapse
|
21
|
Curthoys IS. The interpretation of clinical tests of peripheral vestibular function. Laryngoscope 2012; 122:1342-52. [DOI: 10.1002/lary.23258] [Citation(s) in RCA: 112] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Revised: 01/05/2012] [Accepted: 01/30/2012] [Indexed: 11/09/2022]
|
22
|
Uchino Y, Kushiro K. Differences between otolith- and semicircular canal-activated neural circuitry in the vestibular system. Neurosci Res 2011; 71:315-27. [PMID: 21968226 DOI: 10.1016/j.neures.2011.09.001] [Citation(s) in RCA: 81] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2011] [Revised: 09/09/2011] [Accepted: 09/12/2011] [Indexed: 10/17/2022]
Abstract
In the last two decades, we have focused on establishing a reliable technique for focal stimulation of vestibular receptors to evaluate neural connectivity. Here, we summarize the vestibular-related neuronal circuits for the vestibulo-ocular reflex, vestibulocollic reflex, and vestibulospinal reflex arcs. The focal stimulating technique also uncovered some hidden neural mechanisms. In the otolith system, we identified two hidden neural mechanisms that enhance otolith receptor sensitivity. The first is commissural inhibition, which boosts sensitivity by incorporating inputs from bilateral otolith receptors, the existence of which was in contradiction to the classical understanding of the otolith system but was observed in the utricular system. The second mechanism, cross-striolar inhibition, intensifies the sensitivity of inputs from both sides of receptive cells across the striola in a single otolith sensor. This was an entirely novel finding and is typically observed in the saccular system. We discuss the possible functional meaning of commissural and cross-striolar inhibition. Finally, our focal stimulating technique was applied to elucidate the different constructions of axonal projections from each vestibular receptor to the spinal cord. We also discuss the possible function of the unique neural connectivity observed in each vestibular receptor system.
Collapse
Affiliation(s)
- Yoshio Uchino
- Health Service Facility for the Elderly, "Green Village Angyo", Angyo 1145, Kawaguchi-Shi 334-0059, Saitama Prefecture, Japan.
| | | |
Collapse
|
23
|
Virtual labyrinth model of vestibular afferent excitation via implanted electrodes: validation and application to design of a multichannel vestibular prosthesis. Exp Brain Res 2011; 210:623-40. [PMID: 21380738 DOI: 10.1007/s00221-011-2599-x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2010] [Accepted: 02/07/2011] [Indexed: 10/18/2022]
Abstract
To facilitate design of a multichannel vestibular prosthesis that can restore sensation to individuals with bilateral loss of vestibular hair cell function, we created a virtual labyrinth model. Model geometry was generated through 3-dimensional (3D) reconstruction of microMRI and microCT scans of normal chinchillas (Chinchilla lanigera) acquired with 30-48 μm and 12 μm voxels, respectively. Virtual electrodes were positioned based on anatomic landmarks, and the extracellular potential field during a current pulse was computed using finite element methods. Potential fields then served as inputs to stochastic, nonlinear dynamic models for each of 2,415 vestibular afferent axons with spiking dynamics based on a modified Smith and Goldberg model incorporating parameters that varied with fiber location in the neuroepithelium. Action potential propagation was implemented by a well validated model of myelinated fibers. We tested the model by comparing predicted and actual 3D angular vestibulo-ocular reflex (aVOR) axes of eye rotation elicited by prosthetic stimuli. Actual responses were measured using 3D video-oculography. The model was individualized for each animal by placing virtual electrodes based on microCT localization of real electrodes. 3D eye rotation axes were predicted from the relative proportion of model axons excited within each of the three ampullary nerves. Multiple features observed empirically were observed as emergent properties of the model, including effects of active and return electrode position, stimulus amplitude and pulse waveform shape on target fiber recruitment and stimulation selectivity. The modeling procedure is partially automated and can be readily adapted to other species, including humans.
Collapse
|
24
|
Cross-axis adaptation improves 3D vestibulo-ocular reflex alignment during chronic stimulation via a head-mounted multichannel vestibular prosthesis. Exp Brain Res 2011; 210:595-606. [PMID: 21374081 DOI: 10.1007/s00221-011-2591-5] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2010] [Accepted: 01/31/2011] [Indexed: 10/18/2022]
Abstract
By sensing three-dimensional (3D) head rotation and electrically stimulating the three ampullary branches of a vestibular nerve to encode head angular velocity, a multichannel vestibular prosthesis (MVP) can restore vestibular sensation to individuals disabled by loss of vestibular hair cell function. However, current spread to afferent fibers innervating non-targeted canals and otolith end organs can distort the vestibular nerve activation pattern, causing misalignment between the perceived and actual axis of head rotation. We hypothesized that over time, central neural mechanisms can adapt to correct this misalignment. To test this, we rendered five chinchillas vestibular deficient via bilateral gentamicin treatment and unilaterally implanted them with a head-mounted MVP. Comparison of 3D angular vestibulo-ocular reflex (aVOR) responses during 2 Hz, 50°/s peak horizontal sinusoidal head rotations in darkness on the first, third, and seventh days of continual MVP use revealed that eye responses about the intended axis remained stable (at about 70% of the normal gain) while misalignment improved significantly by the end of 1 week of prosthetic stimulation. A comparable time course of improvement was also observed for head rotations about the other two semicircular canal axes and at every stimulus frequency examined (0.2-5 Hz). In addition, the extent of disconjugacy between the two eyes progressively improved during the same time window. These results indicate that the central nervous system rapidly adapts to multichannel prosthetic vestibular stimulation to markedly improve 3D aVOR alignment within the first week after activation. Similar adaptive improvements are likely to occur in other species, including humans.
Collapse
|
25
|
Curthoys IS. A critical review of the neurophysiological evidence underlying clinical vestibular testing using sound, vibration and galvanic stimuli. Clin Neurophysiol 2009; 121:132-44. [PMID: 19897412 DOI: 10.1016/j.clinph.2009.09.027] [Citation(s) in RCA: 277] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2009] [Revised: 09/08/2009] [Accepted: 09/12/2009] [Indexed: 12/01/2022]
Abstract
In addition to activating cochlear receptors, air conducted sound (ACS) and bone conducted vibration (BCV) activate vestibular otolithic receptors, as shown by neurophysiological evidence from animal studies--evidence which is the foundation for using ACS and BCV for clinical vestibular testing by means of vestibular-evoked myogenic potentials (VEMPs). Recent research is elaborating the specificity of ACS and BCV on vestibular receptors. The evidence that saccular afferents can be activated by ACS has been mistakenly interpreted as showing that ACS only activates saccular afferents. That is not correct - ACS activates both saccular and utricular afferents, just as BCV activates both saccular and utricular afferents, although the patterns of activation for ACS and BCV do not appear to be identical. The otolithic input to sternocleidomastoid muscle appears to originate predominantly from the saccular macula. The otolithic input to the inferior oblique appears to originate predominantly from the utricular macula. Galvanic stimulation by surface electrodes on the mastoids very generally activates afferents from all vestibular sense organs. This review summarizes the physiological results, the potential artifacts and errors of logic in this area, reconciles apparent disagreements in this field. The neurophysiological results on BCV have led to a new clinical test of utricular function - the n10 of the oVEMP. The cVEMP tests saccular function while the oVEMP tests utricular function.
Collapse
Affiliation(s)
- Ian S Curthoys
- Vestibular Research Laboratory, School of Psychology, A 18, The University of Sydney, Sydney, NSW 2006, Australia.
| |
Collapse
|
26
|
Della Santina CC, Migliaccio AA, Patel AH. A multichannel semicircular canal neural prosthesis using electrical stimulation to restore 3-d vestibular sensation. IEEE Trans Biomed Eng 2007; 54:1016-30. [PMID: 17554821 PMCID: PMC2767274 DOI: 10.1109/tbme.2007.894629] [Citation(s) in RCA: 111] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Bilateral loss of vestibular sensation can be disabling. Those afflicted suffer illusory visual field movement during head movements, chronic disequilibrium and postural instability due to failure of vestibulo-ocular and vestibulo-spinal reflexes. A neural prosthesis that emulates the normal transduction of head rotation by semicircular canals could significantly improve quality of life for these patients. Like the three semicircular canals in a normal ear, such a device should at least transduce three orthogonal (or linearly separable) components of head rotation into activity on corresponding ampullary branches of the vestibular nerve. We describe the design, circuit performance and in vivo application of a head-mounted, semi-implantable multichannel vestibular prosthesis that encodes head movement in three dimensions as pulse-frequency-modulated electrical stimulation of three or more ampullary nerves. In chinchillas treated with intratympanic gentamicin to ablate vestibular sensation bilaterally, prosthetic stimuli elicited a partly compensatory angular vestibulo-ocular reflex in multiple planes. Minimizing misalignment between the axis of eye and head rotation, apparently caused by current spread beyond each electrode's targeted nerve branch, emerged as a key challenge. Increasing stimulation selectivity via improvements in electrode design, surgical technique and stimulus protocol will likely be required to restore AVOR function over the full range of normal behavior.
Collapse
Affiliation(s)
- Charles C Della Santina
- Department of Otolaryngology-Head & Neck Surgery, Johns Hopkins School of Medicine, 601 North Caroline Street, Baltimore, MD 21287, USA.
| | | | | |
Collapse
|
27
|
Palla A, Bockisch CJ, Bergamin O, Straumann D. Dissociated Hysteresis of Static Ocular Counterroll in Humans. J Neurophysiol 2006; 95:2222-32. [PMID: 16338995 DOI: 10.1152/jn.01014.2005] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
In stationary head roll positions, the eyes are cyclodivergent. We asked whether this phenomenon can be explained by a static hysteresis that differs between the eyes contra- (CE) and ipsilateral (IE) to head roll. Using a motorized turntable, healthy human subjects ( n = 8) were continuously rotated about the earth-horizontal naso-occipital axis. Starting from the upright position, a total of three full rotations at a constant velocity (2°/s) were completed (acceleration = 0.05°/s2, velocity plateau reached after 40 s). Subjects directed their gaze on a flashing laser dot straight ahead (switched on 20 ms every 2 s). Binocular three-dimensional eye movements were recorded with dual search coils that were modified (wires exiting inferiorly) to minimize torsional artifacts by the eyelids. A sinusoidal function with a first and second harmonic was fitted to torsional eye position as a function of torsional whole body position at constant turntable velocity. The amplitude and phase of the first harmonic differed significantly between the two eyes (paired t-test: P < 0.05): on average, counterroll amplitude of IE was larger [CE: 6.6 ± 1.6° (SD); IE: 8.1 ± 1.7°), whereas CE showed more position lag relative to the turntable (CE: 12.5 ± 10.7°; IE: 5.1 ± 8.7°). We conclude that cyclodivergence observed during static ocular counterroll is mainly a result of hysteresis that depends on whether eyes are contra- or ipsilateral to head roll. Static hysteresis also explains the phenomenon of residual torsion, i.e., an incomplete torsional return of the eyes when the first 360° whole body rotation was completed and subjects were back in upright position (extorsion of CE: 2.0 ± 0.10°; intorsion of IE: 1.4 ± 0.10°). A computer model that includes asymmetric backlash for each eye can explain dissociated torsional hysteresis during quasi-static binocular counterroll. We hypothesize that ocular torsional hysteresis is introduced at the level of the otolith pathways because the direction-dependent torsional position lag of the eyes is related to the head roll position and not the eye position.
Collapse
Affiliation(s)
- A Palla
- Department of Neurology, Zurich University Hospital, Zurich, Switzerland.
| | | | | | | |
Collapse
|
28
|
Goto F, Meng H, Bai R, Sato H, Imagawa M, Sasaki M, Uchino Y. Eye movements evoked by selective saccular nerve stimulation in cats. Auris Nasus Larynx 2004; 31:220-5. [PMID: 15364355 DOI: 10.1016/j.anl.2004.03.002] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2003] [Accepted: 03/19/2004] [Indexed: 10/26/2022]
Abstract
OBJECTIVE Because of technical obstacles in controlling current spread to adjacent peripheral nerve, eye movements evoked by activation of the otolith organs have not been investigated in detail compared to eye movements evoked by activation of the canal organs. We attempted to solve this problem by applying more sensitive methods using fine needle and strictly controlling stimulus current intensity compare with filed potential for selective stimulation. METHODS Eye movements evoked by selective, unilateral saccular (SAC) nerve stimulation were investigated using both electrooculography (EOG) and video recording in decerebrated cats in the presence or absence of anesthesia. Electrical stimulation was applied to the SAC nerve through implanted acupuncture needles. RESULTS In the absence of anesthesia and with stimulus intensities less than (3.1 +/- 2.7) x N(1)T, we found supraduction in both eyes or in either the ipsilateral or contralateral eye of different cats. We observed downward eye movements using a stronger stimulus intensity ((6.2 +/- 2.9)) x N(1)T). The threshold for downward eye movements was significantly greater than that for upward eye movements (P < 0.05). In anesthetized cats, only downward eye movements were observed when stimulus intensities less than 10 x N(1)T ((7.8 +/- 2.3) x N(1)T) were used. CONCLUSION These results confirm the known sacculo-ocular anatomical connections, which are involved predominantly in vertical eye movements. Because the sacculo-ocular connections are relatively weak, the normal supraduction evoked by SAC activation can be easily modified by factors such as level of anesthesia and the method of stimulation.
Collapse
Affiliation(s)
- Fumiyuki Goto
- Department of Physiology, Tokyo Medical University, Japan.
| | | | | | | | | | | | | |
Collapse
|