Rajeev A, Gravett E, Koshy G, Devalia K. The outcomes of constrained total hip arthroplasty for recurrent dislocation of hip hemiarthroplasty. Injury 2023; 54:110970. [PMID: 37595486 DOI: 10.1016/j.injury.2023.110970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 07/30/2023] [Accepted: 07/31/2023] [Indexed: 08/20/2023]
Abstract
INTRODUCTION The incidence of hemiarthroplasty dislocation for fracture neck of femurs ranges between 1 and 15% and the one-year mortality is 49- 70%. Revision of hemiarthroplasty to total hip replacement using a constrained liner has shown to improve the morbidity and mortality rates. The aim of the study was to assess whether conversion of dislocated hemiarthroplasty to total hip replacement improve functional and one year mortality. METHODS A retrospective analysis of the number of patients who had recurrent dislocations of hemiarthroplasty for fracture neck of femurs were carried out. The data were obtained from NHFD (National Hip Fracture Database) and internal hospital computer systems (Medway, Theatre notes and PACS) between Dec 2008 and Dec 2020. Patient demographics including age, sex, Abbreviated Mental Test Score (AMTS), functional assessment, mortality at one and two years were documented. The risk factors which led to dislocations such as Parkinsons disease, Cerebrovascular accidents, Musculo-neuropathies and Alzheimer`s disease was also noted. RESULTS A total of 3994 patients were admitted during the study period of which 1735 (43.4%) patients had hemiarthroplasty. Fifty-six (3.23%) patients had dislocation of hemiarthroplasty. The mean age was 81.4 years (range - 61 to 95). There were 40 (71.4%) females and 16 males (28.6%). The average AMTS score was 5.3. All 56 patients had closed manipulative reduction under anaesthesia within in 12 h of admission. Thirty-one patients (55.4%) went on to have recurrent dislocations of which 18 patients (58.4%) had total hip replacement using captive cup, 6 patients (19.4%) had open reduction,3 patients (9.7%) had excision arthroplasty procedure and four patients (12.5%) had no intervention, Eighteen patients who had total hip replacement with constrained captive for followed up to a minimum of two years (range2- 12 years). There were no intraoperative complications, dislocation or periprosthetic fractures in the follow up period. There was no mortality at the end of two years of follow up in this group, two-year mortality for the patients with alternative management for dislocated hemiarthroplasty was 76.67. CONCLUSION Treatment of recurrent hemiarthroplasty dislocation by revising to a total hip replacement with a constrained liner gives good functional and mortality outcomes.
Collapse
Affiliation(s)
- Aysha Rajeev
- Department of Trauma and Orthopaedics, Gateshead Health Foundation NHS Trust, Sheriff Hill, Gateshead, Tyne and Wear, NE9 6SX, United Kingdom.
| | - Emma Gravett
- Department of Trauma and Orthopaedics, Gateshead Health Foundation NHS Trust, Sheriff Hill, Gateshead, Tyne and Wear, NE9 6SX, United Kingdom
| | - George Koshy
- Department of Trauma and Orthopaedics, Gateshead Health Foundation NHS Trust, Sheriff Hill, Gateshead, Tyne and Wear, NE9 6SX, United Kingdom
| | - Kailash Devalia
- Department of Trauma and Orthopaedics, Gateshead Health Foundation NHS Trust, Sheriff Hill, Gateshead, Tyne and Wear, NE9 6SX, United Kingdom
| |
Collapse
|
2
|
Alberio RL, Rusconi M, Martinetti L, Monzeglio D, Grassi FA. Total Hip Arthroplasty (THA) for Femoral Neck Fractures: Comparison between Standard and Dual Mobility Implants. Geriatrics (Basel) 2021; 6:geriatrics6030070. [PMID: 34287327 PMCID: PMC8293229 DOI: 10.3390/geriatrics6030070] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 07/05/2021] [Accepted: 07/05/2021] [Indexed: 11/21/2022] Open
Abstract
The purpose of this retrospective study is to compare the short-term clinical and radiological results between standard and dual mobility THA for femoral neck fractures (FNF) in older patients. The hypothesis is that the dual mobility cup (DMC) has the same outcomes but a lower dislocation rate than the standard THA. The study population included 56 patients (mean age 77.7 years, range 71–85) that underwent THA for displaced FNF. Patients were divided in two comparable groups for baseline characteristics (age, sex and comorbidities): 28 patients underwent THA with a standard cup (SC) and 28 THA with DMCs. The clinical records and radiograms were reviewed to search relevant data in their postoperative history. Two postoperative dislocations occurred in the SC group and none in the DMC group. At an average follow up of 23 months (12–40), 48 patients were available for the final evaluation. The WOMAC score for all patients averaged 6.26 (0–46) and was slightly better in the DMC group (4.94 vs. 7.58; p-value = 0.41); scores were significantly better in presence of neurological comorbidities (p-value = 0.04), in the absence of diabetes (p-value = 0.04) and in the case of psychiatric disorders (p-value = 0.02). Radiographic evaluation at one year showed signs of osteointegration in 42/48 (87.5%) acetabular components (20 DMCs, 22 SC). According to our experience, DMCs proved to be a valid option for the treatment of displaced FNF in older patients, since it allowed them to achieve short-term outcomes comparable to conventional THA, while decreasing the incidence of postoperative dislocations.
Collapse
Affiliation(s)
- Riccardo L. Alberio
- Orthopaedics and Traumatology Unit, Hospital “Maggiore della Carità”, 28100 Novara, NO, Italy; (R.L.A.); (D.M.); (F.A.G.)
| | - Mattia Rusconi
- Department of Health Sciences, University of East Piedmont, 28100 Novara, NO, Italy;
- Correspondence:
| | - Loris Martinetti
- Department of Health Sciences, University of East Piedmont, 28100 Novara, NO, Italy;
| | - Diego Monzeglio
- Orthopaedics and Traumatology Unit, Hospital “Maggiore della Carità”, 28100 Novara, NO, Italy; (R.L.A.); (D.M.); (F.A.G.)
| | - Federico A. Grassi
- Orthopaedics and Traumatology Unit, Hospital “Maggiore della Carità”, 28100 Novara, NO, Italy; (R.L.A.); (D.M.); (F.A.G.)
- Department of Health Sciences, University of East Piedmont, 28100 Novara, NO, Italy;
| |
Collapse
|
3
|
Sidhu GAS, Kotecha A, Mulay S, Ashwood N. Spontaneous Early Intraprosthetic Dislocation of 22 mm Skirted Femoral Head in Dual Mobility Hip Prosthesis: A Case Report. J Orthop Case Rep 2021; 11:6-9. [PMID: 34239819 PMCID: PMC8241259 DOI: 10.13107/jocr.2021.v11.i03.2062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Introduction: There is a trend for increasing use of dual mobility hip designs for both primary and revision hip arthroplasty settings. It provides dual articular surfaces along with increased jump distance to increase the stability of construct. However, this design has some unique complications of its own which surgeons should be aware of especially intraprosthetic dislocation (IPD). Case Report: A 76-year-old lady presented to clinic with painful hip hemiarthroplasty after fracture neck of femur. She underwent revision surgery with dual mobility uncemented acetabular cup and femoral stem was retained as it was well fixed. She was mobilizing well and around 5 weeks post her surgery, developed pain in hip region and difficulty in weight-bearing. Radiographs showed eccentric position of femoral neck in the socket. A diagnosis of IPD was established and revision surgery was planned. Intraoperatively, metal head had dislocated from the polyethylene head and both components were resting in the acetabular socket. No macroscopic erosion of acetabulum was noticed. The polyethylene component and femoral head were retrieved. With previous failed dual mobility, decision was made to achieve stability with larger head size and lipped liner posteriorly. Conclusion: IPD is a rare occurrence and unique complication to dual mobility implants. This report highlights that patients can have IPD without fall or trauma.
Collapse
Affiliation(s)
- Gur Aziz Singh Sidhu
- Department of Trauma and Orthopaedics, Queens Hospital Burton, University Hospitals of Derby and Burton, United Kingdom
| | - Amit Kotecha
- Department of Trauma and Orthopaedics, Queens Hospital Burton, University Hospitals of Derby and Burton, United Kingdom
| | - Sanjay Mulay
- Department of Trauma and Orthopaedics, Queens Hospital Burton, University Hospitals of Derby and Burton, United Kingdom
| | - Neil Ashwood
- Department of Trauma and Orthopaedics, Queens Hospital Burton, University Hospitals of Derby and Burton, United Kingdom
| |
Collapse
|
4
|
Buller LT, Torres L, Baral EC, Wright TM, Ast MP. No Difference in Force Required for Intraprosthetic Dislocation of Mixed Manufacturer vs Same Manufacturer Dual Mobility Articulations. J Arthroplasty 2020; 35:597-602. [PMID: 31653465 DOI: 10.1016/j.arth.2019.09.039] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2019] [Revised: 09/16/2019] [Accepted: 09/25/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND To avoid the morbidity of removing well-fixed implants during revision surgery, the off-label practice of mixing femoral heads with dual mobility (DM) polyethylene liners from different manufacturers is commonly performed. The resistance to intraprosthetic dislocation, when the inner prosthetic head disengages from the polyethylene bearing, between mixed and same manufacturer constructs remains unknown. METHODS Between January 2010 and July 2018, 168 DM liners were retrieved. Specimens were excluded for catastrophic wear (n = 14), previously levered-out (n = 17), and cases in legal proceedings (n = 8). Using a validated setup, 129 specimens were uniaxially loaded 100 mm from the femoral head until lever-out failure of the head from the liner. The difference in maximum lever-out force (LOF) was compared for same and mixed manufacturer retrievals (Student t-test). Multivariable regression analysis evaluated the influence of potential confounders (length of implantation, head size, head material, presence of skirt) on LOF. RESULTS Ninety-seven same and 32 mixed manufacturer DM constructs were tested. The average LOF for same (272.6 ± 68.7 N) and mixed (299.2 ± 89.0 N) manufacturer specimens was not significantly different (P = .08). An inner head size of 22.2 mm was associated with 184.4-N increase in LOF (P < .001), the presence of a skirt was associated with 63.8-N increase in maximum LOF, and head material (ceramic vs metal) did not influence LOF. CONCLUSION We found no difference in the force required to lever-out same and mixed manufacturer inner heads from DM liners, suggesting that mixing manufacturers when placing DM articulations on well-fixed femoral stems should not increase the risk of intraprosthetic instability.
Collapse
Affiliation(s)
- Leonard T Buller
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY
| | - Lisa Torres
- Department of Biomechanics, Hospital for Special Surgery, New York, NY
| | - Elexis C Baral
- Department of Biomechanics, Hospital for Special Surgery, New York, NY
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, NY
| | - Michael P Ast
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY
| |
Collapse
|
5
|
Romagnoli M, Grassi A, Costa GG, Lazaro LE, Lo Presti M, Zaffagnini S. The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies. INTERNATIONAL ORTHOPAEDICS 2018; 43:1071-1082. [PMID: 30032356 DOI: 10.1007/s00264-018-4062-0] [Citation(s) in RCA: 68] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Accepted: 07/12/2018] [Indexed: 12/19/2022]
Abstract
PURPOSE Although long-term reports of total hip arthroplasty (THA) showed successful results, instability remains a major complication. Recently, dual-mobility cups (DMC) have gained more and more interest among clinicians, with encouraging results in terms of lower rate of dislocation associated with good clinical results, but a lack of evidence exists regarding the real efficacy of this implant design compared to traditional fixed-bearing total hip arthroplasties. METHODS A systematic search was performed in PubMed, Google scholar, Cochrane Library, and EMBASE by two independent reviewers for comparative studies available till December 2017, with the primary objective to demonstrate a real lower dislocation rate of DMC implants compared to unipolar fixed-bearing cup designs. A meta-analysis was conducted with the collected pooled data about dislocation rate, calculating the risk difference (RD) and relative risk (RR) with 95% CI for dichotomous variables. Heterogeneity was tested using the χ2 and Higgins' I2 tests. A fixed-effect model was used because the statistical heterogeneity was below 50%. RESULTS After performing a critical exclusion process, the number of eligible studies included for final synthesis considered was 15, describing the results of a total of 2408 total hip arthroplasties (50.6% with a dual-mobility acetabular cup design, 49.4% with a standard fixed-bearing design). The fixed-effect meta-analysis showed a slight significant risk ratio of 0.16 (95% CI, 0.09, 0.28; I2 = 0%, p < 0.00001); a statistically significant difference in favor of the DMC group was maintained also considering only primary or revision arthroplasties, traumatic fractures or elective patients with diagnosis of osteoarthritis, avascular osteonecrosis or rheumatic arthritis. CONCLUSIONS With the intrinsic limitations of our study design and based on the current available data, this study demonstrates that dual-mobility acetabular components decrease the risk of post-operative instability also in high-risk patients, both in primary and revision hip arthroplasties. However, new high-quality studies, possibly with a randomized control design, should be undertaken in order to strengthen the present data. STUDY DESIGN Level of Evidence III, therapeutic study.
Collapse
Affiliation(s)
- Matteo Romagnoli
- II Orthopaedic Clinic and Biomechanics Laboratory, IRCSS Istituto Ortopedico Rizzoli, Via di Barbiano n. 1/10, 40136, Bologna, Italy
| | - Alberto Grassi
- II Orthopaedic Clinic and Biomechanics Laboratory, IRCSS Istituto Ortopedico Rizzoli, Via di Barbiano n. 1/10, 40136, Bologna, Italy
| | - Giuseppe Gianluca Costa
- II Orthopaedic Clinic and Biomechanics Laboratory, IRCSS Istituto Ortopedico Rizzoli, Via di Barbiano n. 1/10, 40136, Bologna, Italy.
| | - Lionel E Lazaro
- Hospital for Special Surgery and New York Presbyterian Hospital, 535 East 70th Street, New York, NY, 10021, USA
| | - Mirco Lo Presti
- II Orthopaedic Clinic and Biomechanics Laboratory, IRCSS Istituto Ortopedico Rizzoli, Via di Barbiano n. 1/10, 40136, Bologna, Italy
| | - Stefano Zaffagnini
- II Orthopaedic Clinic and Biomechanics Laboratory, IRCSS Istituto Ortopedico Rizzoli, Via di Barbiano n. 1/10, 40136, Bologna, Italy
| |
Collapse
|
6
|
Harwin SF, Sultan AA, Khlopas A, Chughtai M, Sodhi N, Piuzzi NS, Mont MA. Mid-Term Outcomes of Dual Mobility Acetabular Cups for Revision Total Hip Arthroplasty. J Arthroplasty 2018; 33:1494-1500. [PMID: 29307678 DOI: 10.1016/j.arth.2017.12.008] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 12/04/2017] [Accepted: 12/05/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND This study evaluated (1) survivorship, (2) clinical outcomes, (3) complications, and (4) radiographic outcomes of dual mobility (DM) systems when compared to fixed-bearing prostheses in revision total hip arthroplasty (THA). METHODS A cohort of 85 patients who underwent revision THA using DM implants were compared to a prior matching cohort of 170 patients who received fixed-bearing implants. Mean follow-up time was 4 years in the DM cohort and 10 years in the fixed-bearing cohort. Kaplan-Meier analysis was performed to assess survivorships. Clinical outcomes were evaluated using the Harris Hip Score (HHS). Complications and radiographs were evaluated and reported at the final follow-up. RESULTS Overall aseptic and all-cause survivorships of the DM cohort were 96.5% and 95.3% compared to 94.7% and 93.5% in fixed-bearing cohort (P = .01 for aseptic and all-cause survivorships). The DM cohort had statistically significant higher survivorship when compared at equivalent follow-up interval in the fixed-bearing cohort. There were 3 aseptic (one due to dislocation) and 1 septic revision in the DM cohort compared to 9 aseptic (6 due to dislocation) and 2 septic revisions in the fixed-bearing cohort. Postoperative HHS scores were 88 and 86 points in the DM and fixed-bearing cohorts. However, the difference in mean improvement in HHS scores from preoperative to postoperative (ΔHHS) was not statistically significant (35 vs 34, P = .533). Except for the aforementioned revisions, there were no progressive radiolucencies or osteolysis on radiographic evaluation in both cohorts. CONCLUSION DM articulations demonstrated superior survivorship at equal follow-up intervals when compared to fixed-bearing implants and showed a trend toward lower dislocation rates.
Collapse
Affiliation(s)
- Steven F Harwin
- Department of Advanced Technology of Total Hip and Knee Arthroplasty, Mount Sinai West Hospital, New York, NY
| | - Assem A Sultan
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Anton Khlopas
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Morad Chughtai
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Nipun Sodhi
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Nicolas S Piuzzi
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - Michael A Mont
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| |
Collapse
|
7
|
De Martino I, D'Apolito R, Waddell BS, McLawhorn AS, Sculco PK, Sculco TP. Early intraprosthetic dislocation in dual-mobility implants: a systematic review. Arthroplast Today 2017; 3:197-202. [PMID: 28913407 PMCID: PMC5585769 DOI: 10.1016/j.artd.2016.12.002] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Revised: 12/07/2016] [Accepted: 12/09/2016] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Dual mobility implants are subject to a specific implant-related complication, intraprosthetic dislocation (IPD), in which the polyethylene liner dissociates from the femoral head. For older generation designs, IPD was attributable to late polyethylene wear and subsequent failure of the head capture mechanism. However, early IPDs have been reportedly affecting contemporary designs. METHODS A systematic review of the literature according to the preferred reporting items for systematic reviews and meta-analyses guidelines was performed. A comprehensive search of PubMed, MEDLINE, Embase, and Google Scholar was conducted for English articles between January 1974 and August 2016 using various combinations of the keywords "intraprosthetic dislocation," "dual mobility," "dual-mobility," "tripolar," "double mobility," "double-mobility," "hip," "cup," "socket," and "dislocation." RESULTS In all, 16 articles met our inclusion criteria. Fourteen were case reports and 2 were retrospective case series. These included a total of 19 total hip arthroplasties, which were divided into 2 groups: studies dealing with early IPD after attempted closed reduction and those dealing with early IPD with no history of previous attempted closed reduction. Early IPD was reported in 15 patients after a mean follow-up of 3.2 months (2.9 SD) in the first group and in 4 patients after a mean follow-up of 15.1 months (9.9 SD) in the second group. CONCLUSIONS Based on the current data, most cases have been preceded by an attempted closed reduction in the setting of outer, large articulation dislocation, perhaps indicating an iatrogenic etiology for early IPD. Recognition of this possible failure mode is essential to its prevention and treatment.
Collapse
Affiliation(s)
- Ivan De Martino
- Department of Orthopaedic Surgery, Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY, USA
| | - Rocco D'Apolito
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY, USA
| | - Bradford S. Waddell
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY, USA
| | - Alexander S. McLawhorn
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY, USA
| | - Peter K. Sculco
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY, USA
| | - Thomas P. Sculco
- Department of Orthopaedic Surgery, Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
8
|
Retrieval evidence of impingement at the third articulation in contemporary dual mobility cups for total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2017; 41:2495-2501. [PMID: 28578471 DOI: 10.1007/s00264-017-3523-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Accepted: 05/16/2017] [Indexed: 02/08/2023]
Abstract
PURPOSE We aimed to assess polyethylene liners of retrieved hips of one design of a dual mobility (DM) cup liner and two designs of femoral stems to better understand the role of femoral stem design on polyethylene impingement. METHODS This was a case-control study involving 70 retrieved highly cross-linked polyethylene (X3) liners used with ABGII (n = 35) and Rejuvenate (n = 35) stems (Stryker). All polyethylene liners were assessed for evidence of rim deformation and the damage quantified using metrology methods. RESULTS A total of 80% of polyethylene liners paired with ABGII necks had macroscopic evidence of neck impingement resulting in a raised lip whilst 23% of liners paired with Rejuvenate necks had evidence of a raised lip (p < 0.0001). The height of the raised rims of the DM cups paired with ABGII necks had a median (range) of 139 μm (72-255). The height of the raised rims of the DM cups paired with Rejuvenate necks had a median (range) of 52 μm (45-90) (p < 0.0001). CONCLUSION Our new findings from retrieved dual mobility bearings showed that polyethylene liner rim deformation resulting from impingement with the femoral neck occurs in early in-human function, is circumferential in distribution, and is affected by the stem neck design. We recommend the use of highly polished and non-edged neck designs when used in conjunction with DM cups.
Collapse
|
9
|
Abstract
Dislocation remains a common cause of failure after total hip arthroplasty. The limitations of existing approaches to address instability have led to the development of powerfull options: constrained liners, dual mobility and large heads. These implant-related options have proven to be very efficient, but have raised concerns.With constrained liners, restricted range of motion (ROM) is responsible for impingement leading to high likelihood of failure, depending on the design, with various failure modes.Improvements of the bearing materials have addressed some of the concerns about increased volumetric wear of conventional polyethylene and offer an option to reduce instability: large diameter heads have the advantage of increased ROM before impingement, increased head-neck ratio, and jump distance. Highly cross-linked polyethylene helps address the risk for increased wear, and also large heads provide improved stability without the risk of mechanical failures observed with constrained liners. However, the increase of the head size remains limited as reducing the thickness of the liner may lead to fractures. In addition, the jump distance decreases as the cup abduction increases.The dual mobility concept simultaneously attempts to address head-neck ratio, constraint, and jump distance. Despite the need for longer follow-up, concerns raised about potential increased wear and intra-prosthetic dislocation with first generation implants have been addressed with modern designs.With a dramatic increase of the head-neck ratio whilst reducing the risk of mechanical failure or excessive wear, dual mobility THA outperforms large diameter heads and constrained liners at 10 years follow-up. For these reasons, dual mobility continues to gain interest worldwide and is becoming the most popular option to manage instability. Cite this article: Guyen O. Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA. EFORT Open Rev 2016;1:197-204. DOI: 10.1302/2058-5241.1.000054.
Collapse
Affiliation(s)
- Olivier Guyen
- Department of Orthopaedic Surgery, Lausanne University Hospital, Lausanne, Switzerland
| |
Collapse
|
10
|
Batailler C, Fary C, Verdier R, Aslanian T, Caton J, Lustig S. The evolution of outcomes and indications for the dual-mobility cup: a systematic review. INTERNATIONAL ORTHOPAEDICS 2016; 41:645-659. [PMID: 28004142 DOI: 10.1007/s00264-016-3377-y] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 12/11/2016] [Indexed: 01/12/2023]
Abstract
PURPOSE Instability following total hip arthroplasty remains a common and disabling complication. The dual mobility cup (DMC) allows a reduction in the dislocation rate. An increasing number of studies have been undertaken to better understand DMC long term outcomes and complications. The goal of this systematic review was to clarify its different uses and outcomes according to the indications. METHODS A comprehensive literature review was performed using the keywords 'dual mobility' and 'tripolar cup' with no limit regarding the year of publication. One hundred seventy six publications were identified. RESULTS Current literature shows that "contemporary" dual mobility cup are a significant indication to manage instability following primary and revision hip arthroplasty. Survivorship at midterm is comparable to other articulations for primary THA, but is more difficult to evaluate in revision. Intra-prosthetic dislocation, wear, and loosening are now uncommon with new generations of DMC. CONCLUSIONS Compared to previous generations of DMC, the current "contemporary" DMC presents a significant improvement. Current literature reveals a tendency to increase the indications but further studies with long term follow up remain important to consolidate these findings.
Collapse
|
11
|
Wear of dual-mobility cups: a review article. INTERNATIONAL ORTHOPAEDICS 2016; 41:625-633. [DOI: 10.1007/s00264-016-3326-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 10/17/2016] [Indexed: 12/26/2022]
|
12
|
Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA. Clin Orthop Relat Res 2016; 474:2181-7. [PMID: 27106128 PMCID: PMC5014802 DOI: 10.1007/s11999-016-4811-6] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Dislocation complicates 1% to 5% of primary total hip arthroplasties (THAs). As a result, some surgeons consider dual-mobility articulations, which are usually used in the revision setting to decrease the likelihood of dislocation, as an option for primary THA. However, few studies have evaluated their use in this setting. QUESTIONS/PURPOSES (1) What is the cup survivorship when the dual-mobility articulation is used in the setting of primary THA? (2) What are the clinical outcomes with this approach? (3) What are the radiographic outcomes? (4) What are the complications of dual-mobility articulations in primary THA? METHODS Between 2011 and 2013, the five participating surgeons performed 495 cementless primary THAs. During that time, one of the five surgeons used dual-mobility articulations for all THAs, and the other four used it whenever the acetabular cup size was 52 mm or greater to enable a 28-mm head. Of the 495 patients, 453 (92%) were performed using this device. Smaller patients were treated with a standard THA. Of the 453 patients, a total of 43 patients (10%) were lost to followup before the 2-year minimum. The resulting 410 patients who were included in the analysis (164 men, 246 women) had a mean age of 64 years (SD, 12 years). The mean followup was 3 years (SD, 0.7 years). We performed Kaplan-Meier analyses to assess survivorship to aseptic failure and all-cause acetabular component survivorship. Clinical outcomes were evaluated using the Harris hip score (HHS); radiographs were assessed for cup migration, progressive radiolucencies, and positional changes of the components; and any surgery-related complications were recorded. RESULTS The survivorship to aseptic failure and all-cause acetabular component survivorship was 99.8% (failures, n = 1) (95% confidence interval [CI], 4.517-4.547) and 99.3% (failures, aseptic, n = 1; septic, n = 2) (95% CI, 4.494-4.543); one hip had trunnion notching caused by impingement of a malpositioned cup, which was treated with revision of the cup and stem; and two patients had periprosthetic infections that were treated with two-stage revisions. There were no dislocations. Patients had a mean HHS of 94 (SD, 6) at final followup. On radiographic evaluation, no progressive radiolucencies or positional changes of the components were identified. Surgical complications included one traumatic avulsion of the abductors, one traumatic avulsion of the greater trochanter, which was repaired without revision of any of the components, and one loose femoral stem, which required revision of the femoral component only. CONCLUSIONS Dual-mobility cups in primary THA yield seemingly comparable survivorship and complications to conventional THA bearings at short-term followup. Because serious complications have occasionally been reported with the use of these bearings, larger, longer term, comparative-and ideally, randomized-trials will be needed to establish the superiority of one approach over the other. Until or unless such studies show the superiority of dual-mobility designs for primary THA, we recommend that in the setting of uncomplicated primary THA, dual-mobility articulations be used only in centers that track their results carefully or in research protocols. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
|
13
|
Fehring KA, Berry DJ. Dissociation and Intrapelvic Entrapment of a Dual-mobility Polyethylene Component. Clin Orthop Relat Res 2016; 474:1072-6. [PMID: 26088765 PMCID: PMC4773345 DOI: 10.1007/s11999-015-4381-z] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2015] [Accepted: 05/28/2015] [Indexed: 01/31/2023]
Abstract
BACKGROUND Dual-mobility bearings have gained popularity in recent years as a proposed method of reducing the risk of dislocation after primary and revision hip arthroplasties. Intraprosthetic dislocation, defined as dissociation of the smaller femoral head from the larger outer polyethylene head, is a known complication of these designs. Intraprosthetic dislocation typically requires reoperation and revision as closed reduction of intraprosthetic dislocations of these components is not effective. The small femoral head typically remains inside the large diameter acetabular component during intraprosthetic dislocation, thus the diagnosis may be missed if femoral head eccentricity is not identified on radiographs. Intraprosthetic dislocation leads to a free polyethylene bearing which typically stays in the joint space, however in theory, migration of the bearing is possible. CASE DESCRIPTION We report a case of polyethylene bearing disengagement and intrapelvic entrapment after anterior dislocation of a hip with a modern dual-mobility bearing. The diagnosis of polyethylene component migration to an intrapelvic location was not made until surgery. Isolated acetabular revision of the dual-mobility bearing was performed to correct the instability in this patient. The entrapped polyethylene head was left in its intrapelvic position as retrieval was thought to be more morbid than retention of the component. LITERATURE REVIEW Intraprosthetic dislocation, with disassociation of the polyethylene bearing from the femoral head, is a known complication of dual-mobility designs. Reports of intrapelvic entrapment of trial femoral heads of conventional hip arthroplasties have been described extensively in the literature. To our knowledge, intrapelvic migration and entrapment of a polyethylene bearing after dislocation of a hip with a dual-mobility implant has not been reported. CLINICAL RELEVANCE We discuss an implant-specific complication that has not been reported, and surgeons should be aware that this unique complication can occur. Surgeons should recognize the eccentricity of the femoral head on postreduction radiographs so an intraprosthetic dislocation is not missed. Furthermore, surgeons should be aware that intraprosthetic dislocation carries a risk of intrapelvic migration of the polyethylene component which is not visible on plain radiographs.
Collapse
Affiliation(s)
- Keith A. Fehring
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA
| | - Daniel J. Berry
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA
| |
Collapse
|
14
|
Waddell BS, De Martino I, Sculco T, Sculco P. Total Hip Arthroplasty Dislocations Are More Complex Than They Appear: A Case Report of Intraprosthetic Dislocation of an Anatomic Dual-Mobility Implant After Closed Reduction. Ochsner J 2016; 16:185-190. [PMID: 27303232 PMCID: PMC4896666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023] Open
Abstract
BACKGROUND Total hip arthroplasty is a successful operation for the treatment of hip pain. One of the common complications of hip arthroplasty is dislocation. While reduction of standard prosthetic dislocations is highly successful, new prostheses add the potential for new complications. CASE REPORT We present the case of a patient who experienced intraprosthetic dislocation of an anatomic dual-mobility total hip prosthesis after a closed hip reduction and include the prereduction and postreduction radiographic findings. CONCLUSION Emergency department physicians should be aware of intraprosthetic dislocation. This complication can be easily missed because the metal/ceramic femoral head appears to be reduced in the acetabulum.
Collapse
Affiliation(s)
- Bradford S. Waddell
- Department of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | - Ivan De Martino
- Department of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | - Thomas Sculco
- Department of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | - Peter Sculco
- Department of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| |
Collapse
|
15
|
Carulli C, Macera A, Matassi F, Civinini R, Innocenti M. The use of a dual mobility cup in the management of recurrent dislocations of hip hemiarthroplasty. J Orthop Traumatol 2015; 17:131-6. [PMID: 26187813 PMCID: PMC4882292 DOI: 10.1007/s10195-015-0365-8] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Accepted: 06/15/2015] [Indexed: 01/22/2023] Open
Abstract
Background Dislocation is one of the most frequent causes of failure of hemiarthroplasties of the hip, which is the most common treatment for femoral neck fractures in elderly patients. A revision with conversion to total hip arthroplasty is the gold standard in case of failure of closed reduction: however, the use of standard or modular components shows variable outcomes. The use of a dual mobility cup has been evaluated in patients with unstable implants, given the good outcomes obtained in primary and revision surgery. The aim of this study was to assess the results of revisions by dual mobility cups in unstable hemiarthroplasties. Materials and methods Thirty-one patients (mean age 75.4 years) were retrospectively evaluated between 2006 and 2010 after conversion to total hip arthroplasty with dual mobility cups for recurrent dislocations. The mean number of dislocations was 2.6 (range 2–5). The evaluation was performed by the American Society of Anesthesiologists physical function score (ASA) and the Harris hip score, and several radiologic criteria. Results The mean follow-up was 3.8 years. No recurrence of dislocation was recorded. The ASA score remained unchanged, and the mean Harris hip score improved from 62.2 before dislocation to 76.0 points postoperatively. Conclusions Dual mobility cups may be a useful option in the treatment of a hemiarthroplasty dislocation. No risk of a new revision due to instability after insertion of dual mobility cups resulted in our experience, and this option may be strongly considered in cases of revisions of unstable hemiarthroplasties. Level of evidence IV.
Collapse
Affiliation(s)
- Christian Carulli
- Orthopaedic Clinic, University of Florence, Largo P. Palagi 1, 50139, Florence, Italy.
| | - Armando Macera
- Orthopaedic Clinic, University of Florence, Largo P. Palagi 1, 50139, Florence, Italy
| | - Fabrizio Matassi
- Orthopaedic Clinic, University of Florence, Largo P. Palagi 1, 50139, Florence, Italy
| | - Roberto Civinini
- Orthopaedic Clinic, University of Florence, Largo P. Palagi 1, 50139, Florence, Italy
| | - Massimo Innocenti
- Orthopaedic Clinic, University of Florence, Largo P. Palagi 1, 50139, Florence, Italy
| |
Collapse
|
16
|
Cvetanovich GL, Fillingham YA, Della Valle CJ, Sporer SM. Intraprosthetic Dislocation of Dual-Mobility Bearings Associated with Closed Reduction. JBJS Case Connect 2015; 5:e26. [PMID: 29252604 DOI: 10.2106/jbjs.cc.n.00137] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
CASE We present two patients with dual-mobility total hip arthroplasty components who underwent closed reduction of posterior dislocations with conscious sedation in the emergency room. Following closed reduction, both patients had immediate pain, clicking, and grinding of the hip. Radiographs identified intraprosthetic dislocation of the dual-mobility components, and revision surgery was required. CONCLUSION When dislocation of a dual-mobility bearing occurs, the surgeon should consider performing a careful closed reduction with muscle paralysis and use of fluoroscopic guidance in the operating room to avoid intraprosthetic dislocation.
Collapse
Affiliation(s)
- Gregory L Cvetanovich
- Midwest Orthopaedics at Rush, 1611 West Harrison Avenue, Chicago, IL 60612. E-mail address for G.L. Cvetanovich:
| | - Yale A Fillingham
- Midwest Orthopaedics at Rush, 1611 West Harrison Avenue, Chicago, IL 60612. E-mail address for G.L. Cvetanovich:
| | - Craig J Della Valle
- Midwest Orthopaedics at Rush, 1611 West Harrison Avenue, Chicago, IL 60612. E-mail address for G.L. Cvetanovich:
| | - Scott M Sporer
- Midwest Orthopaedics at Rush, 1611 West Harrison Avenue, Chicago, IL 60612. E-mail address for G.L. Cvetanovich:
| |
Collapse
|
17
|
Odland AN, Sierra RJ. Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA. Orthopedics 2014; 37:e1124-8. [PMID: 25437088 DOI: 10.3928/01477447-20141124-90] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2013] [Accepted: 04/28/2014] [Indexed: 02/03/2023]
Abstract
Although dual-mobility sockets have been in clinical use for decades in other parts of the world, they recently gained popularity in the United States as an option for primary and revision total hip arthroplasty (THA). Improvements in dual-mobility socket technology include articulation with a metal insert impacted into a metal shell and a femoral head made of highly cross-linked polyethylene. The results and complications associated with the use of dual-mobility sockets employing these technologic advancements are not known. Specifically, intraprosthetic dislocation is a well-known complication of these implants and has been reported extensively in the literature. To the authors' knowledge, its occurrence in a modern dual-mobility socket has not been reported. The authors report a case of early intraprosthetic dislocation of a contemporary dual-mobility design used to convert a patient to THA after failed fixation of intertrochanteric hip fracture. At retrieval, there was evidence that the outer bearing may have ceased moving, causing localized focal impingement of the implant neck on the retentive ring. The authors theorized that external hip impingement (pelvic against trochanter) and previous surgery that led to the formation of scar tissue could have caused the outer bearing surface to cease its motion. This ultimately led to impingement of the femoral component neck on the retentive ring, which led to the intraprosthetic dislocation. Dual-mobility cups provide an attractive option to decrease wear and improve stability. Further research is needed to establish the ideal construct design and materials.
Collapse
|
18
|
Langlois J, El Hage S, Hamadouche M. Intraprosthetic dislocation: a potentially serious complication of dual mobility acetabular cups. Skeletal Radiol 2014; 43:1013-6. [PMID: 24522771 DOI: 10.1007/s00256-014-1824-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2013] [Revised: 01/06/2014] [Accepted: 01/09/2014] [Indexed: 02/02/2023]
Abstract
Though dual mobility cups have gained growing popularity as a solution for instability in total hip replacements, these promising devices are subject to a specific implant failure mode, named intraprosthetic dislocation. We present the case of a patient sustaining such an adverse event. The planned revision surgery was postponed 12 months due to a severe heart condition, allowing a rare opportunity to document the natural history of this unusual complication. The small femoral head was found dislodged in the superior part of the metallic shell and had remarkably lost its sphericity. Severe metallic debris and granuloma were found in the proximal femoral region, associated with major periprosthetic bony and soft tissue damage. Surgeons, radiologists, and general practitioners should be aware of this specific complication, its incidence (almost 5%) and mechanisms (femoral neck to mobile polyethylene insert impingement, leading to rim fatigue and wear of the insert at the capturing area). Diagnosis is mainly based on anteroposterior and modified Lowenstein lateral radiographs of the hip, as an eccentric position of the small femoral head, lying against the concave inner surface of the shell. Prompt component revision should be planned, since delayed management could lead to severe irretrievable damages.
Collapse
Affiliation(s)
- Jean Langlois
- Department of Orthopaedic and Reconstructive Surgery, Hopital Cochin, 27 Rue du Faubourg St. Jacques, 75014, Paris, France,
| | | | | |
Collapse
|