1
|
Van Meirhaeghe JP, Harris IA, Cuthbert A, Lorimer M, McAuliffe M, Adie S, Molnar R. The influence of implant factors on patient outcomes in primary total knee arthroplasty. J Orthop 2024; 58:154-160. [PMID: 39157416 PMCID: PMC11326491 DOI: 10.1016/j.jor.2024.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 07/15/2024] [Indexed: 08/20/2024] Open
Abstract
Background The influence of implant factors on patient-reported outcome measures (PROMS) after total knee arthroplasty (TKA) has previously been studied but findings are often inconsistent, restricted in scope and biased by confounding factors. This study aims to determine the association between implant-related factors and early post-operative PROMs after TKA. Methods Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) PROMs program, the study included 9487 primary TKA procedures performed in 43 hospitals from July 31, 2018 to December 31, 2020. Data included baseline demographic data, surgical details and PROMs collected pre- and 6 months post-operatively. Seven prosthesis characteristics were incorporated in the multivariable model, with proportional odds ordinal regression analysis used to assess their effects on post-operative Oxford knee score (OKS) and joint pain. Adjustments were made for pre-operative OKS and joint pain, as well as potential patient confounders. Results At six months, fixed bearing implants showed higher odds of better OKS compared to mobile bearing implants (odds ratio [OR] = 1.20, 95 % confidence interval [CI] 1.06-1.37. p < 0.004). Similar findings were found with the use of image derived instrumentation (IDI) (OR = 1.27, 95 % CI 1.11-1.46, p < 0.001), robotic assisted vs. non-navigated knees (OR = 1.21, 95 % CI 1.06-1.38, p < 0.005) and no patella resurfacing (OR = 1.10, 95 % CI 1.01-1.20, p < 0.032). For lower pain scores at six months, the use of highly crosslinked polyethylene (OR = 1.12, 95 % CI 1.02-1.22, p < 0.015), cemented femoral components (OR = 1.11, 95 % CI 1.01-1.22, p < 0.024), IDI (OR = 1.20, 95 % CI 1.05-1.37, p < 0.009) or no patella resurfacing (OR = 1.10, 95 % CI 1.01-1.20, p < 0.034) were associated. Conclusion Utilizing a fixed bearing or robotic assistance correlated with improved OKS scores, whereas highly crosslinked polyethylene or cemented femoral components were associated with improved pain scores. At six months, the use of IDI compared to non-navigated TKA, and patellar resurfacing showed both improved OKS and pain scores.
Collapse
Affiliation(s)
- Jan Peter Van Meirhaeghe
- Sydney Orthopaedic Trauma and Reconstructive Surgery (SOTRS), Sydney, Australia
- Department of Orthopaedics, University Hospital of Ghent, Ghent, Belgium
| | - Ian A. Harris
- School of Clinical Medicine, Faculty of Medicine and Health, UNSW Sydney, Australia
| | - Alana Cuthbert
- South Australian Health & Medical Research Institute (SAHMRI), Australia
| | - Michelle Lorimer
- South Australian Health & Medical Research Institute (SAHMRI), Australia
| | - Michael McAuliffe
- Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), Australia
- Queensland University of Technology (QUT - Gardens Point), Australia
| | - Sam Adie
- St. George and Sutherland Hospitals, Sydney, Australia
- St. George and Sutherland Clinical School, UNSW, Australia
| | - Robert Molnar
- St. George and Sutherland Hospitals, Sydney, Australia
- St. George and Sutherland Clinical School, UNSW, Australia
| |
Collapse
|
2
|
Stratton-Powell AA, Williams S, Tipper JL, Redmond AC, Brockett CL. Isolation and characterisation of wear debris surrounding failed total ankle replacements. Acta Biomater 2023; 159:410-422. [PMID: 36736850 DOI: 10.1016/j.actbio.2023.01.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Revised: 01/18/2023] [Accepted: 01/20/2023] [Indexed: 02/04/2023]
Abstract
Aseptic loosening and osteolysis continue to be a short- to mid-term problem for total ankle replacement (TAR) devices. The production of wear particles may contribute to poor performance, but their characteristics are not well understood. This study aimed to determine the chemical composition, size and morphology of wear particles surrounding failed TARs. A recently developed wear particle isolation method capable of isolating both high- and low-density materials was applied to 20 retrieved periprosthetic tissue samples from 15 failed TARs of three different brands. Isolated particles were imaged using ultra-high-resolution imaging and characterised manually to determine their chemical composition, size, and morphology. Six different materials were identified, which included: UHMWPE, calcium phosphate (CaP), cobalt chromium alloy (CoCr), commercially pure titanium, titanium alloy and stainless steel. Eighteen of the 20 samples contained three or more different wear particle material types. In addition to sub-micron UHMWPE particles, which were present in all samples, elongated micron-sized shards of CaP and flakes of CoCr were commonly isolated from tissues surrounding AES TARs. The mixed particles identified in this study demonstrate the existence of a complex periprosthetic environment surrounding TAR devices. The presence of such particles suggests that early failure of devices may be due in part to the multifaceted biological cascade that ensues after particle release. This study could be used to support the validation of clinically-relevant wear simulator testing, pre-clinical assessment of fixation wear and biological response studies to improve the performance of next generation ankle replacement devices. STATEMENT OF SIGNIFICANCE: Total ankle replacement devices do not perform as well as total hip and knee replacements, which is in part due to the relatively poor scientific understanding of how they fail. The excessive production of certain types of wear debris is known to contribute to joint replacement failure. This is the first study to successfully isolate and characterise high- and low-density wear particles from tissues collected from patients with a failed total ankle replacement. This article includes the chemical composition and characteristics of the wear debris generated by ankle devices, all of which may affect their performance. This research provides clinically relevant reference values and images to support the development of pre-clinical testing for future total ankle replacement designs.
Collapse
Affiliation(s)
- Ashley A Stratton-Powell
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK.
| | - Sophie Williams
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
| | - Joanne L Tipper
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK; School of Biomedical Engineering, University of Technology Sydney, Ultimo 2007, Australia
| | - Anthony C Redmond
- NIHR Leeds Biomedical Research Centre, Leeds Teaching Hospitals NHS Trust, UK; Leeds Institute for Rheumatic and Musculoskeletal Medicine, School of Medicine, University of Leeds, UK
| | - Claire L Brockett
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK; NIHR Leeds Biomedical Research Centre, Leeds Teaching Hospitals NHS Trust, UK
| |
Collapse
|
3
|
Stratton‐Powell AA, Williams S, Tipper JL, Redmond AC, Brockett CL. Mixed material wear particle isolation from periprosthetic tissue surrounding total joint replacements. J Biomed Mater Res B Appl Biomater 2022; 110:2276-2289. [PMID: 35532138 PMCID: PMC9540445 DOI: 10.1002/jbm.b.35076] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 11/05/2021] [Accepted: 04/18/2022] [Indexed: 12/12/2022]
Affiliation(s)
- Ashley A. Stratton‐Powell
- Institute of Medical and Biological Engineering, School of Mechanical Engineering University of Leeds Leeds UK
| | - Sophie Williams
- Institute of Medical and Biological Engineering, School of Mechanical Engineering University of Leeds Leeds UK
| | - Joanne L. Tipper
- Institute of Medical and Biological Engineering, School of Mechanical Engineering University of Leeds Leeds UK
- School of Biomedical Engineering University of Technology Sydney Ultimo New South Wales Australia
| | - Anthony C. Redmond
- NIHR Leeds Biomedical Research Centre Leeds Teaching Hospitals NHS Trust Leeds UK
- Leeds Institute for Rheumatic and Musculoskeletal Medicine, School of Medicine University of Leeds Leeds UK
| | - Claire L. Brockett
- Institute of Medical and Biological Engineering, School of Mechanical Engineering University of Leeds Leeds UK
- NIHR Leeds Biomedical Research Centre Leeds Teaching Hospitals NHS Trust Leeds UK
| |
Collapse
|
4
|
Bistolfi A, Giustra F, Bosco F, Faccenda C, Viotto M, Sabatini L, Berchialla P, Sciannameo V, Graziano E, Massè A. Comparable results between crosslinked polyethylene and conventional ultra-high molecular weight polyethylene implanted in total knee arthroplasty: systematic review and meta-analysis of randomised clinical trials. Knee Surg Sports Traumatol Arthrosc 2022; 30:3120-3130. [PMID: 35182171 PMCID: PMC9418273 DOI: 10.1007/s00167-022-06879-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Accepted: 01/12/2022] [Indexed: 12/17/2022]
Abstract
PURPOSE Total knee arthroplasty (TKA) has experienced exponential growth over the last decade, including increasingly younger patients with high functional demands. Highly crosslinked polyethylene (HXLPE) has been proven effective in reducing osteolysis and loosening revisions while improving long-term survival and performance in total hip arthroplasty; nevertheless, this superiority is not demonstrated in TKA. The aim of this systematic review and meta-analysis was to examine whether HXLPE improved overall survival and postoperative functional and radiological outcomes compared to conventional polyethylene (CPE) in TKA. METHODS According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline, a literature search of five databases (PubMed, Medline, Scopus, Science Direct and Embase) was made. A PICOS model was performed. The initial screening identified 2541 studies. Each eligible clinical article was analysed according to the Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence (LoE). Only randomised clinical trials (RCTs) of LoE 1 and 2 were included. The methodological quality of the articles was assessed using the Risk of Bias 2 (RoB 2) tool. RESULTS Six clinical studies were included in the final study. This systematic review and meta-analysis were registered on the International Prospective Register of Systematic Reviews (PROSPERO). A total of 2285 knees were included. Eight outcomes (total reoperations, reoperations for prosthesis loosening and infections, radiolucent lines, osteolysis, mechanical failure, postoperative KSS knee score and function score) were analysed. For none of them, a statistically significant difference was found about the superiority of HXLPE over CPE (p > 0.05). CONCLUSIONS There were no statistically significant differences between HXLPE and CPE for TKA concerning clinical, radiological, and functional outcomes; nevertheless, HXLPE did not show higher failure rates or complications and can be safely used for TKA. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Alessandro Bistolfi
- Orthopaedics and Traumatology, Ospedale Cardinal Massaia Asti, via Conte Verde 125, 14100 Asti, Italy
| | | | | | | | | | - Luigi Sabatini
- grid.432329.d0000 0004 1789 4477AO Città della Salute e della Scienza, Turin, Italy
| | - Paola Berchialla
- grid.7605.40000 0001 2336 6580Department of Clinical and Biological Sciences, University of Torino, Turin, Italy
| | - Veronica Sciannameo
- grid.7605.40000 0001 2336 6580Department of Clinical and Biological Sciences, University of Torino, Turin, Italy
| | - Eugenio Graziano
- Orthopaedics and Traumatology, Ospedale Cardinal Massaia Asti, via Conte Verde 125, 14100 Asti, Italy
| | - Alessandro Massè
- University of the Studies of Turin, Turin, Italy ,grid.432329.d0000 0004 1789 4477AO Città della Salute e della Scienza, Turin, Italy
| |
Collapse
|
5
|
Bistolfi A, Giustra F, Bosco F, Sabatini L, Aprato A, Bracco P, Bellare A. Ultra-high molecular weight polyethylene (UHMWPE) for hip and knee arthroplasty: The present and the future. J Orthop 2021; 25:98-106. [PMID: 33994706 PMCID: PMC8102204 DOI: 10.1016/j.jor.2021.04.004] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 04/18/2021] [Indexed: 10/21/2022] Open
Abstract
PURPOSE to review advances and clinical performance of polyethylene in total joint arthroplasty, summing up historical problems and focusing on the latest innovations. METHODS search for medical grade Ultra-High-Molecular-Weight-Polyethylene (UHMWPE); Data Sources: PubMed, Scopus, Cochrane Library. RESULTS the increasing number of joint arthroplasties and high-activity patients led to progressive developments of bearing surfaces to improve performance and durability. Different strategies such as crosslinking UHMWPE (HXLPE) and the addition of vitamin-E (HXLPE) have been tested to improve wear and oxidation resistance. CONCLUSION Recent innovations about UHMWPE showed improvements either for hip and knee, with the potential of long-term survivorship.
Collapse
Affiliation(s)
- Alessandro Bistolfi
- Department of Orthopaedics, Traumatology and Rehabilitation, C.T.O. Hospital. AOU Città della Salute e della Scienza, Via Zuretti 29, 10126, Turin, Italy
| | - Fortunato Giustra
- Department of Orthopaedics, Traumatology and Rehabilitation, C.T.O. Hospital. AOU Città della Salute e della Scienza, Via Zuretti 29, 10126, Turin, Italy
| | - Francesco Bosco
- Department of Orthopaedics, Traumatology and Rehabilitation, C.T.O. Hospital. AOU Città della Salute e della Scienza, Via Zuretti 29, 10126, Turin, Italy
| | - Luigi Sabatini
- Department of Orthopaedics, Traumatology and Rehabilitation, C.T.O. Hospital. AOU Città della Salute e della Scienza, Via Zuretti 29, 10126, Turin, Italy
| | - Alessandro Aprato
- Department of Orthopaedics, Traumatology and Rehabilitation, C.T.O. Hospital. AOU Città della Salute e della Scienza, Via Zuretti 29, 10126, Turin, Italy
| | - Pierangiola Bracco
- Department of Chemistry and NIS (Nanostructured Interfaces and Surfaces) Center, University of Torino, 10125, Torino, Italy
| | | |
Collapse
|
6
|
Chacko Rajan S, Bretcanu O, Deehan DJ, Joyce TJ. Retrieval analysis of two contemporary total knee designs: Influence of femoral component roughness and type of polyethylene. J Mech Behav Biomed Mater 2020; 104:103620. [PMID: 32174387 DOI: 10.1016/j.jmbbm.2020.103620] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 12/24/2019] [Accepted: 01/05/2020] [Indexed: 10/25/2022]
Affiliation(s)
- Shannen Chacko Rajan
- School of Engineering, Newcastle University, NE1 7RU, Newcastle Upon Tyne, England, UK.
| | - Oana Bretcanu
- School of Engineering, Newcastle University, NE1 7RU, Newcastle Upon Tyne, England, UK
| | | | - Thomas Jonathan Joyce
- School of Engineering, Newcastle University, NE1 7RU, Newcastle Upon Tyne, England, UK
| |
Collapse
|
7
|
Wilhelm SK, Henrichsen JL, Siljander M, Moore D, Karadsheh M. Polyethylene in total knee arthroplasty: Where are we now? J Orthop Surg (Hong Kong) 2019; 26:2309499018808356. [PMID: 30369289 DOI: 10.1177/2309499018808356] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Polyethylene (PE) remains the gold standard for the articulating surface in hip and knee arthroplasty. To increase arthroplasty longevity and improve wear resistance, newer versions of PE have been designed with resultantly different wear properties. Highly cross-linked polyethylene (HXLPE) is used in total hip arthroplasty with excellent outcomes; however, its use in total knee arthroplasty (TKA) remains conflicting. This review summarizes biomechanical and wear properties, clinical outcomes, and cost of polyethylene inserts in TKA. Simulation studies have convincingly shown decreased wear and oxidation rates with HXLPE when compared to conventional polyethylene (CPE). Registry results have been conflicting, and short- to midterm clinical studies have not demonstrated a significant difference between HXLPE and CPE. The cost of HXLPE inserts is higher than CPE. Long-term clinical data are lacking and further studies are warranted to evaluate the role of HXLPE in TKA.
Collapse
Affiliation(s)
- Spencer K Wilhelm
- 1 Oakland University William Beaumont School of Medicine, Michigan, USA
| | | | | | - Drew Moore
- 2 Beaumont Health System, Orthopaedic Surgery, Michigan, USA
| | - Mark Karadsheh
- 2 Beaumont Health System, Orthopaedic Surgery, Michigan, USA
| |
Collapse
|
8
|
Cross-linked polyethylene does not reduce wear in total knee arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2018. [DOI: 10.1016/j.recote.2018.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
9
|
Minoda Y, Hata K, Goto K, Itohara T, Nakamura H. Sequentially annealed highly cross-linked polyethylene reduced in vivo wear particle generation in total knee arthroplasty. J Orthop Surg (Hong Kong) 2018; 25:2309499017718909. [PMID: 28681671 DOI: 10.1177/2309499017718909] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION Sequentially annealed highly cross-linked polyethylene (HXLPE) was recently introduced to reduce the wear in total knee arthroplasty (TKA). However, an in vivo advantage of sequentially annealed HXLPE on wear particle generation is still controversial. The purpose of this study is to compare the characteristics of in vivo wear particles between sequentially annealed HXLPE and conventional polyethylene after TKA. MATERIALS AND METHODS Synovial fluid was obtained from the eight knees with sequentially annealed HXLPE and from eight knees with conventional polyethylene 12 months after the operation. Polyethylene particles were isolated and examined using a scanning electron microscope and image analyzer. RESULTS Total number of wear particles in each knee was 2.1 ± 1.0 × 107 with sequentially annealed HXLPE (mean ± standard deviation) and 4.9 ± 3.6 × 107 with conventional polyethylene ( p = 0.036). Particle size (equivalent circle diameter) was 1.01 ± 0.26 μm with sequentially annealed HXLPE and 1.02 ± 0.20 μm with conventional polyethylene ( p = 0.674). Aspect ratio was 1.33 ± 0.04 with sequentially annealed HXLPE and 1.39 ± 0.10 with conventional polyethylene ( p = 0.462). CONCLUSIONS The sequentially annealed HXLPE reduced the in vivo polyethylene wear particles by 58% compared with conventional polyethylene without the significant change of particle size and shape.
Collapse
Affiliation(s)
- Yukihide Minoda
- 1 Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Abeno-ku, Osaka, Japan.,2 Department of Orthopaedic Surgery, Shitennouji Hospital, Tennouji-ku, Osaka, Japan
| | - Kanako Hata
- 1 Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Abeno-ku, Osaka, Japan
| | - Katsuko Goto
- 2 Department of Orthopaedic Surgery, Shitennouji Hospital, Tennouji-ku, Osaka, Japan
| | - Tomonobu Itohara
- 2 Department of Orthopaedic Surgery, Shitennouji Hospital, Tennouji-ku, Osaka, Japan
| | - Hiroaki Nakamura
- 1 Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Abeno-ku, Osaka, Japan
| |
Collapse
|
10
|
Lasurt-Bachs S, Torner P, Maculé F, Prats E, Menéndez-García F, Ríos-Guillermo J, Torrents A. Cross-linked polyethylene does not reduce wear in total knee arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2018; 62:197-203. [PMID: 29454601 DOI: 10.1016/j.recot.2017.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 11/22/2017] [Accepted: 11/29/2017] [Indexed: 10/18/2022] Open
Abstract
AIM To compare two different types of inserts: Ultra-high molecular weight polyethylene (UHMWPE) and cross-linked polyethylene with a quantitative and qualitative study of polyethylene wear particles in synovial fluid 3 years after total knee arthroplasty. MATERIAL AND METHODS A prospective, randomized, controlled cohort study with blinded evaluation was carried out on 25 patients undergoing staged bilateral total knee replacement, 6 months apart. Knee arthrocentesis was performed on 12 patients 3 years after surgery, and the polyethylene particles were analyzed. RESULTS No significant differences were found in the number of particles generated by the two different types of inserts at 3 years from total knee arthroplasty (3,000×: x¯ cross-linked=849.7; x¯ UHMWPE=796.9; P=.63; 20,000×: x¯ cross-linked=66.3; x¯ UHMWPE=73.1; P=.76). Likewise, no differences in the probability of finding elongated (χ2=0.19; P=.66) or rounded (χ2=1.44; P=.23) particles in both types of inserts were observed. However, the probability of finding fibrillar particles is 3.08 times greater in UHMWPE. CONCLUSIONS Cross-linked polyethylene does not significantly reduce the generation of polyethylene particles in patients with total knee arthroplasty, 3 years after the surgical procedure.
Collapse
Affiliation(s)
- S Lasurt-Bachs
- Unitat de Genoll, Servei de Cirurgia Ortopèdica i Traumatologia, Consorci Sanitari Integral Baix Llobregat, Universitat de Barcelona, Barcelona, España.
| | - P Torner
- Servei de Cirurgia Ortopèdica i Traumatologia, Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí I3PT, Sabadell, Barcelona, España; Universitat Autònoma de Barcelona (UAB), Barcelona, España
| | - F Maculé
- Unidad de Rodilla, Servicio de Cirugía Ortopédica y Traumatología, Hospital Clínic, Universitat de Barcelona, Barcelona, España
| | - E Prats
- Departamento de Microscopía Electrónica, Centres Científics i Tecnològics de la UB (CCiTUB), Barcelona, España
| | - F Menéndez-García
- Unidad de Análisis Elemental, Centres Científics i Tecnològics de la Universitat de Barcelona (CCiTUB), Barcelona, España
| | - J Ríos-Guillermo
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Departamento de Estadística, Hospital Clínic, Universitat de Barcelona, Barcelona, España
| | - A Torrents
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Departamento de Estadística, Hospital Clínic, Universitat de Barcelona, Barcelona, España
| |
Collapse
|
11
|
Comparison of in vivo polyethylene wear particles between mobile- and fixed-bearing TKA in the same patients. Knee Surg Sports Traumatol Arthrosc 2017; 25:2887-2893. [PMID: 26846659 DOI: 10.1007/s00167-016-4027-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Accepted: 01/22/2016] [Indexed: 10/22/2022]
Abstract
PURPOSE Polyethylene wear particle generation is one of the most important factors that affects the mid- to long-term results of total knee arthroplasties (TKA). Mobile-bearing total knee prostheses were developed to reduce polyethylene wear generation. However, whether mobile-bearing prostheses actually generate fewer polyethylene wear particles than fixed-bearing prostheses remains controversial. The aim of this study was to compare, within individual patients, the in vivo polyethylene wear particles created by a newly introduced mobile-bearing prosthesis in one knee and a conventional fixed-bearing prosthesis in other knee. METHODS Eighteen patients receiving bilateral TKAs to treat osteoarthritis were included. The synovial fluid was obtained from 36 knees at an average of 3.5 years after the operation. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined using a scanning electron microscope and an image analyser. RESULTS The size and shape of the polyethylene wear particles from the mobile-bearing prostheses were similar to those from the conventional fixed-bearing prostheses. Although the number of wear particles from the mobile-bearing prosthesis (1.63 × 107 counts/knee) appeared smaller than that from the fixed-bearing prosthesis (2.16 × 107 counts/knee), the difference was not statistically significant. CONCLUSIONS The current in vivo study shows that no statistically significant differences were found between the polyethylene wear particles generated by a newly introduced mobile-bearing PS prosthesis and a conventional fixed-bearing PS prosthesis during the early clinical stage after implantation. LEVEL OF EVIDENCE Therapeutic study, Level III.
Collapse
|
12
|
Grupp TM, Fritz B, Kutzner I, Schilling C, Bergmann G, Schwiesau J. Vitamin E stabilised polyethylene for total knee arthroplasty evaluated under highly demanding activities wear simulation. Acta Biomater 2017; 48:415-422. [PMID: 27789345 DOI: 10.1016/j.actbio.2016.10.031] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 09/30/2016] [Accepted: 10/22/2016] [Indexed: 01/12/2023]
Abstract
As total knee arthroplasty (TKA) patients are getting more active, heavier and younger and structural material fatigue and delamination of tibial inserts becomes more likely in the second decade of good clinical performance it appears desirable to establish advanced pre-clinical test methods better characterizing the longterm clinical material behaviour. The questions of our study were 1) Is it possible to induce subsurface delamination and striated pattern wear on standard polyethylene TKA gliding surfaces? 2) Can we distinguish between γ-inert standard polyethylene (PEstand.30kGy) as clinical reference and vitamin E stabilised materials (PEVit.E30kGy & PEVit.E50kGy)? 3) Is there an influence of the irradiation dose (30vs 50kGy) on oxidation and wear behaviour? Clinical relevant artificial ageing (ASTM F2003; 2weeks) of polyethylene CR fixed TKA inserts and oxidation index measurements were performed by Fourier transform infrared spectroscopy prior testing. The oxidation index was calculated in accordance with ISO 5834-4:2005 from the area ratio of the carbonyl peak (between 1650 and 1850cm-1) to the reference peak for polyethylene (1370cm-1). Highly demanding patient activities (HDA) measured in vivo were applied for 5million knee wear cycles in a combination of 40% stairs up, 40% stairs down, 10% level walking, 8% chair raising and 2% deep squatting with up to 100° flexion. After 3.0mc all standard polyethylene gliding surfaces developed noticeable areas of progressive delamination. Cumulative gravimetric wear was 355.9mg for PEstand.30kGy, 28.7mg for PEVit.E30kGy and 26.5mg for PEVit.E50kGy in HDA knee wear simulation. Wear rates were 12.4mg/mc for PEstand.30kGy in the linear portion (0-2mc), 5.6mg/mc for PEVit.E30kGy and 5.3mg/mc for PEVit.E50kGy. In conclusion, artificial ageing of standard polyethylene to an oxidation index of 0.7-0.95 in combination with HDA knee wear simulation, is able to create subsurface delamination, structural material fatigue in vitro, whereas for the vitamin-E-blended materials no evidence of progressive wear, fatigue or delamination was found. STATEMENT OF SIGNIFICANCE As total knee arthroplasty patients are getting more active, heavier and younger and structural material fatigue and delamination of polyethylene tibial inserts becomes more likely in the second decade of good clinical performance, it appears desirable to establish advanced pre-clinical test methods better characterizing the longterm clinical material behaviour. Various studies reported in literature attempted to artificially create delamination during in vitro knee wear simulation. We combined artificial ageing to clinically observed oxidation of gamma inert and vitamin E stabilised polyethylene inserts and highly demanding patient activities knee wear simulation based on in vivo load data. With this new method we were able to create clinically relevant subsurface delamination and structural material fatigue on standard polyethylene inserts in vitro.
Collapse
|
13
|
Renner L, Faschingbauer M, Boettner F. Is there a rationale to use highly cross-linked polyethylene in posterior-stabilized total knee arthroplasty? ANNALS OF TRANSLATIONAL MEDICINE 2015; 3:63. [PMID: 25992362 DOI: 10.3978/j.issn.2305-5839.2015.01.17] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Subscribe] [Scholar Register] [Received: 01/06/2015] [Accepted: 01/07/2015] [Indexed: 11/14/2022]
Affiliation(s)
- Lisa Renner
- Hospital for Special Surgery, New York, NY 10021, USA
| | | | | |
Collapse
|
14
|
Matziolis G, Röhner E. [Total knee arthroplasty in 2014 : Results, expectations, and complications]. DER ORTHOPADE 2015; 44:255-8, 560. [PMID: 25854189 DOI: 10.1007/s00132-015-3080-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Aseptic loosening seems to have become a minor problem in total knee arthroplasty. In contrast to that, new challenges are defined by changing patients' expectations. Beside reduction of pain and improving mobility, modern implants should not be noticed as such and should not limit sports activities. OBJECTIVES In this paper, a summary of the development and the current situation of total knee arthroplasty (e.g., implantation numbers, hospitality, operation time, and infection rates) are provided. The data are compared in an international context. In addition, current trends and developments from recent years are shown and rated according to the literature. MATERIALS AND METHODS The paper is based on a literature search (PubMed) and analyses of published official statistical data and expert recommendations. RESULTS Implantation numbers have been declining gradually in Germany since 2009. In 2013, 127,077 total knee arthroplasties were implanted. In contrast, the number of revision operations has increased gradually during the last decade. In addition, hospital stay and operation time have declined. CONCLUSION The development of implants, instruments, and operation techniques results from changing patients' expectations. All innovations must be compared against the results of well-proven techniques. The arthroplasty register may be an instrument to evaluate the results of new techniques and implants in a broad clinical application in terms of survival.
Collapse
Affiliation(s)
- G Matziolis
- Orthopädische Klinik, Friedrich-Schiller Universität Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Deutschland,
| | | |
Collapse
|
15
|
Colwell CW. CORR Insights®: Is there a difference in TKA risk of revision in highly crosslinked versus conventional polyethylene? Clin Orthop Relat Res 2015; 473:1009-10. [PMID: 25608487 PMCID: PMC4317446 DOI: 10.1007/s11999-015-4145-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Accepted: 01/08/2015] [Indexed: 01/31/2023]
Affiliation(s)
- Clifford W. Colwell
- Shiley Center for Orthopaedic Research & Education at Scripps Clinic, 11025 North Torrey Pines Road, Suite 200, La Jolla, CA 92037 USA
| |
Collapse
|
16
|
Affiliation(s)
- Zachary D Post
- The Rothman Institute, 925 Chestnut Street, 5th Floor, Philadelphia, PA 19107
| | - Carl Deirmengian
- The Rothman Institute, 925 Chestnut Street, 5th Floor, Philadelphia, PA 19107
| | - Jess H Lonner
- The Rothman Institute, 925 Chestnut Street, 5th Floor, Philadelphia, PA 19107
| |
Collapse
|
17
|
Abstract
Previous studies of failure mechanisms leading to revision total knee replacement (TKR) performed between 1986 and 2000 determined that many failed early, with a disproportionate amount accounted for by infection and implant-associated factors including wear, loosening and instability. Since then, efforts have been made to improve implant performance and instruct surgeons in best practice. Recently our centre participated in a multi-centre evaluation of 844 revision TKRs from 2010 to 2011. The purpose was to report a detailed analysis of failure mechanisms over time and to see if failure modes have changed over the past 10 to 15 years. Aseptic loosening was the predominant mechanism of failure (31.2%), followed by instability (18.7%), infection (16.2%), polyethylene wear (10.0%), arthrofibrosis (6.9%) and malalignment (6.6%). The mean time to failure was 5.9 years (ten days to 31 years), 35.3% of all revisions occurred at less than two years, and 60.2% in the first five years. With improvements in implant and polyethylene manufacture, polyethylene wear is no longer a leading cause of failure. Early mechanisms of failure are primarily technical errors. In addition to improving implant longevity, industry and surgeons must work together to decrease these technical errors. All reports on failure of TKR contain patients with unexplained pain who not infrequently have unmet expectations. Surgeons must work to achieve realistic patient expectations pre-operatively, and therefore, improve patient satisfaction post-operatively.
Collapse
Affiliation(s)
- A V Lombardi
- Joint Implant Surgeons, 7277 Smith's Mill Road, Suite 200, New Albany, Ohio, 43054, USA
| | - K R Berend
- Joint Implant Surgeons, 7277 Smith's Mill Road, Suite 200, New Albany, Ohio, 43054, USA
| | - J B Adams
- Joint Implant Surgeons, 7277 Smith's Mill Road, Suite 200, New Albany, Ohio, 43054, USA
| |
Collapse
|