1
|
Spece H, Yarbrough RV, Kurtz SM. In Vivo Performance of Vitamin E Stabilized Polyethylene Implants for Total Hip Arthroplasty: A Review. J Arthroplasty 2022; 38:970-979. [PMID: 36481286 DOI: 10.1016/j.arth.2022.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/28/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Vitamin E stabilization was introduced to improve the oxidative stability, wear resistance, and mechanical properties of highly crosslinked polyethylene (HXLPE). In this literature review, we asked: (1) How has vitamin E-stabilized HXLPE (VEPE) performed in vivo for total hip arthroplasty (THA) and how does it compare with conventional ultra-high molecular weight polyethylene (UHMWPE) and HXLPE without vitamin E; and (2) Is there an apparent difference in the clinical performance of VEPE created by blending versus diffusion? METHODS We performed a systematic search of the literature according to the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines using PubMed and Embase. Included studies reported the in vivo behavior of VEPE in THA. We reviewed 41 studies. RESULTS For all studies that compared polyethylene with and without VE stabilization, outcomes for VEPE were either equivalent or superior to the control group (for HXLPE without VE and conventional UHMWPE controls, respectively). Hip insert wear rates were generally less than 0.1 mm/year and in most cases were less than 0.05 mm/year. No VEPE components were revised for osteolysis or adverse outcomes specific to VE incorporation. CONCLUSION Across the literature, we found that VEPE was reported to be clinically effective for THA applications, with much of the research indicating positive clinical outcomes and lower or equivalent wear rates compared to conventional UHMWPE and HXLPE controls without VE. Instances of early component fracture were reported, but have multiple potential causes. There is a gap in the literature for comparison of blended and diffused components, so the in vivo impact of VE incorporation method remains to be seen. Overall, this study provides a comprehensive summary of VEPE clinical performance for THA and may serve as a resource for future investigations.
Collapse
Affiliation(s)
- Hannah Spece
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA; Gyroid, LLC, Haddonfield, NJ
| | | | - Steven M Kurtz
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA; Gyroid, LLC, Haddonfield, NJ
| |
Collapse
|
2
|
Elbardesy H, Yadav H, Rabea M, Guerin S, Harty J. Femoral head penetration in Vitamin-E polyethylene liner versus conventional liners in total hip arthroplasty: systematic review and meta-analysis of randomised control trials. SICOT J 2021; 7:47. [PMID: 34515633 PMCID: PMC8436949 DOI: 10.1051/sicotj/2021045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 08/11/2021] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Debate encompasses the use of Vitamin E Polyethylene or conventional Polyethylene liner in primary hip arthroplasty. Does the Inclusion of Vitamin E in PE give adequate protection from oxidation and maintains lower rates of wear? PATIENTS AND METHODS We performed this study following the Preferred Reporting Items for Systematic Reviews and Meta-analyses Statement (PRISMA) and the Cochrane Handbook for systematic reviews and meta-analysis. Studies were included from any region, written in any language. We had only the randomised control trials comparing the femoral head penetration between Vitamin-E diffused highly cross-linked polyethylene (VEPE) liner and conventional liners in primary total hip arthroplasty. RESULTS We included 10 studies in this meta-analysis. We conducted them using Review Manager V.5.0. We computed the risk ratio to measure the treatment effect, considering the heterogeneity. We used Random-effect models. VEPE had insignificant marginal advantages for FHP within three months post-operative. Additionally, VEPE showed significantly less FHP after two and five years. After one year, it showed significantly less FHP with the VEPE group versus the UHMWPE cohort and a non-significant difference between the VEPE and XLPE group. CONCLUSIONS In terms of FHP, this metanalysis shows less FHP for the VEPE than conventional PE. A longer follow-up period is required to evaluate whether the oxidation protection gained by Vitamin E results in lower wear rates, less osteolysis, and aseptic loosening compared to the conventional PE in the long term.
Collapse
Affiliation(s)
- Hany Elbardesy
- Department of Trauma and Orthopaedic, Cork University Hospital, Wilton, Cork T12DFK4, Ireland
| | - Himanshu Yadav
- Department of Trauma and Orthopaedic, Cork University Hospital, Wilton, Cork T12DFK4, Ireland
| | - Mohamed Rabea
- Faculty of Pharmacy, Mansoura University, Mansoura 32216, Egypt
| | - Shane Guerin
- Department of Trauma and Orthopaedic, Cork University Hospital, Wilton, Cork T12DFK4, Ireland
| | - James Harty
- Department of Trauma and Orthopaedic, Cork University Hospital, Wilton, Cork T12DFK4, Ireland
| |
Collapse
|
3
|
Mahmood FF, Beck M, de Gast A, Rehbein P, French GJ, Becker R, Dominkus M, Helmy N, Hollmann L, Baines J. Survivorship and Patient-Reported Outcomes of an Uncemented Vitamin E-Infused Monoblock Acetabular Cup: A Multicenter Prospective Cohort Study. J Arthroplasty 2021; 36:1700-1706. [PMID: 33516632 DOI: 10.1016/j.arth.2020.12.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 12/16/2020] [Accepted: 12/18/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Addition of vitamin E to polyethylene is theorized to reduce the potential for oxidative wear in acetabular components. This paper presents a multicenter prospective cohort study that reports on outcomes from use of a Vitamin E-infused highly cross-linked polyethylene acetabular cup. METHODS Patients were recruited across nine medical institutions. Clinical outcome measures recorded were the Harris Hip Score, visual analogue score for pain and satisfaction. Evidence of implant loosening or osteolysis was collected radiologically. Cup survival and reasons for revision in relevant cases were also recorded. Data collection was undertaken preoperatively, at 6-12 weeks, 6 months, 1 year, 2 years, and 5 years. A total of 675 patients were recruited, with 450 cases available at final review. Data regarding cup survival was available to 8 years and 9 months postoperatively. RESULTS Improvements in both the Harris Hip Score and visual analogue score for pain and satisfaction were recorded at all time points, with these being maintained through the length of follow-up. In total, 89% of cups were implanted within the Lewinnek safe zone. A lucent line was identified in one case, with no evidence of acetabular osteolysis observed throughout the follow-up period. Cup survival was 98.9% at 8 years and 9 months. No revisions for aseptic loosening were observed. CONCLUSIONS The use of a vitamin E-infused polyethylene acetabular cup demonstrates reassuring patient-reported outcomes, radiological measures, and cup survival at medium to long-term follow-up.
Collapse
Affiliation(s)
- Fahd F Mahmood
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| | - Martin Beck
- Luzerner Kantonsspital, Luzern, Switzerland; Orthopaedic Clinic Lucerne, Hirslanden Clinic St. Anna, Lucerne
| | - Arthur de Gast
- Diakonessenhuis Utrecht, Utrecht, the Netherlands; Clinical Orthopedic Research Center Midden-Nederland, Diakonessenhuis Zeist, Zeist, the Netherlands
| | - Philipp Rehbein
- Department of Orthopaedics, St. Josefs-Hospital Wiesbaden, Wiesbaden, Germany
| | | | - Roland Becker
- Dept. of Orthopedics and Traumatology, Brandenburg Medical School, Brandenburg, Germany
| | - Martin Dominkus
- Orthopaedic Department, Orthopädisches Spital Speising, Wien, Austria; Sigmund Freud University, Campus Prater Freudplatz 1, Wien, Austria
| | - Naeder Helmy
- Department of Orthopaedics, Nurgerspital Solothurn, Solothurn, Switzerland
| | - Lutz Hollmann
- Streekziekenhuis Koningin Beatrix, Winterswijk, the Netherlands
| | - Joe Baines
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| |
Collapse
|
4
|
Comtesse S, de Gast A, Rehbein P, French G, Helmy N, Becker R, Dominkus M, Beck M. Wear and migration are not influenced by head size in a vitamin E-infused highly cross-linked polyethylene acetabular cup. Orthop Traumatol Surg Res 2021; 107:102644. [PMID: 33384276 DOI: 10.1016/j.otsr.2020.03.030] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 03/19/2020] [Accepted: 03/24/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND Aseptic loosening and periprosthetic osteolysis are frequent complications in total hip arthroplasty requiring revision surgery. Highly cross-linked polyethylene (HXLPE) implants have improved wear resistance, permitting larger femoral heads. However, such implants may experience surface cracking, mechanical failure, and oxidative damage. Vitamin E-infused HXLPE (VEPE) implants were therefore developed to reduce oxidation without compromising mechanical strength. We addressed the following questions: (1) Does femoral head size affect the midterm annual polyethylene wear rates of VEPE acetabular cups? (2) Does femoral head size affect the midterm migration rates of VEPE acetabular cups? (3) Are clinical outcomes affected by femoral head size? HYPOTHESIS Annual wear rate, migration rate, and clinical outcomes of VEPE acetabular cups are independent of femoral head size. PATIENTS AND METHODS This was a prospective, multicentre, observational study of patients that underwent total hip arthroplasty. Hips were grouped according to the size of femoral head implanted (28 mm, 32 mm, and 36 mm). We determined annual wear rate and migration rate of VEPE acetabular cups using the Einzel-Bild-Röntgen-Analyse software. Clinically, we assessed the Harris Hip Score and visual analog score for pain and satisfaction. RESULTS We followed 253 patients (267 hips) for a mean of 55.0±20.6 months in the 28 mm, 46.2±21.4 months in the 32 mm, and 43.8±22.6 months in the 36 mm group. The annual wear rate was 0.025 mm per year from 1 year to the last follow-up and remained similar between the groups (p>0.05). Also, mean two-dimensional migration rates did not exceed 0.05 mm from 2 years to the last follow-up and remained similar between the groups (p=0.355). Finally, clinical outcomes also did not differ between the groups (p>0.05). Two patients required revision surgery. DISCUSSION Femoral head size did not influence midterm annual wear rate, migration rate, and clinical outcomes of VEPE acetabular cups. Furthermore, wear and cup migration rates were below the reported values leading to osteolysis and aseptic loosening. Nevertheless, studies with extended follow-up periods will be necessary to confirm these results in the long term. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Simon Comtesse
- Mathys Ltd Bettlach, Robert-Mathys Strasse 5, 2544 Bettlach, Switzerland
| | - Arthur de Gast
- Diakonessenhuis Utrecht, Bosboomstraat 1, 3582 KE Utrecht, Netherlands; Clinical Orthopedic Research Centre midden-Nederland, Diakonessenhuis Zeist, Jagersingel 1, 3707 HL Zeist, Netherlands
| | - Philipp Rehbein
- St. Josefs-Hospital Wiesbaden, Beethovenstraße 20, 65189 Wiesbaden, Germany
| | - Gary French
- Ormiston Hospital, 125, Ormiston Road, Flat Bush, 2016 Manukau, New Zealand
| | - Naeder Helmy
- Bürgerspital Solothurn, Schöngrünstrasse 42, 4500 Solothurn, Switzerland
| | - Roland Becker
- Zentrum für Orthopädie und Unfallchirurgie, Endoprothesenzentrum West-Brandenburg, Medizinische Hochschule Theodor Fontane, 14776 Brandenburg/Havel, Germany
| | - Martin Dominkus
- Orthopädisches Spital Speising, Speisinger Straße 109, 1130 Wien, Austria; Sigmund-Freud University, Campus Prater Freudplatz 1, 1020 Wien, Austria
| | - Martin Beck
- Luzerner Kantonsspital, Spitalstrasse, 6000 Luzern, Switzerland.
| |
Collapse
|
5
|
Afghanyar Y, Joser S, Tecle J, Drees P, Dargel J, Rehbein P, Kutzner KP. The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up. BMC Musculoskelet Disord 2021; 22:107. [PMID: 33485345 PMCID: PMC7827971 DOI: 10.1186/s12891-021-03981-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 01/17/2021] [Indexed: 11/10/2022] Open
Abstract
Background The newest generation of cementless titanium-coated, isoelastic monoblock cup with vitamin E-blended highly cross-linked polyethylene (HXLPE) was introduced to the market in 2009. The aim of the present study was to obtain mid-term follow-up data including migration and wear analyses. Methods This prospective study investigated 101 primary total hip arthroplasty (THA) cases in 96 patients treated at a single institution. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) and pain and satisfication on a visual analogue scale (VAS) were assessed at a mean follow-up of 79.0 months. Migration and wear were assessed using Einzel-Bild-Roentgen-Analyse (EBRA) software. Radiological acetabular bone alterations and complications were documented. Results At mid-term follow-up (mean 79.0 months, range: 51.8–101.7), 81 cases with complete clinical and radiological data were analyzed. Utilisable EBRA measurements were obtained for 42 hips. The mean HHS was 91.1 (range 38.0–100.0), VAS satisfaction was 9.6 (range 6.0–10.0), VAS rest pain was 0.2 (range 0.0–4.0), and VAS load pain was 0.6 (range 0.0–9.0). Mean migration was 0.86 mm (range: 0.0–2.56) at 24 months and 1.34 mm (range: 0.09–3.14) at 5 years, and the mean annual migration rate was 0.22 (range: − 0.24–1.34). The mean total wear was 0.4 mm (range: 0.03–1.0), corresponding to a mean annual wear rate of 0.06 mm per year (range: 0.0–0.17). Radiographic analysis did not reveal any cases of osteolysis, and no revision surgeries had to be performed. Conclusions After using vitamin-E blended HXLPE in cementless isoelastic monoblock cups, there were no obvious signs of osteolysis or aseptic loosening occurred. No patients required revision surgery after mid-term follow-up. Cup migration and wear values were well below the benchmarks considered predictive for potential future failure. Trial registration The trial registration number on ClinicalTrials.gov: NCT04322916 (retrospectively registered at 26.03.2020). Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-03981-8.
Collapse
Affiliation(s)
- Yama Afghanyar
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany.
| | - Sebastian Joser
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Jonas Tecle
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Drees
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - Jens Dargel
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Karl Philipp Kutzner
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany.,Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| |
Collapse
|
6
|
Massier JRA, Van Erp JHJ, Snijders TE, Gast ADE. A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients. Acta Orthop 2020; 91:705-710. [PMID: 32835560 PMCID: PMC8023918 DOI: 10.1080/17453674.2020.1807220] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Survivorship of total hip arthroplasty (THA) with the ultra-high molecular weight polyethylene (UHMWPE) monoblock cup has been limited due to periprosthetic osteolysis and aseptic loosening, secondary to wear of the UHMWPE. In response, a vitamin E blended highly cross-linked polyethylene (HXLPE) cup was developed. This study set out to compare the wear and clinical 6-year outcomes of vitamin E blended HXLPE with UHMWPE in an isoelastic monoblock cup in patients with hip osteoarthritis who underwent uncemented THA. The 2-year results have been reported previously. Patients and methods - For this randomized controlled trial 199 patients were included. 102 patients received the vitamin E blended HXLPE uncemented acetabular cup and 97 patients the uncemented UHMWPE monoblock cup. Clinical and radiographic parameters were obtained preoperatively, directly postoperatively, and at 3, 12, 24, and 72 months. Wear rates were compared using the femoral head penetration (FHP) rate. Results - 173 patients (87%) completed the 6-year follow-up. The mean NRS scores for rest pain, load pain, and patient satisfaction were 0.3 (SD 1), 0.6 (SD 1), and 8.6 (SD 1) respectively. The mean Harris Hip Score was 93 (SD 12). The FHP rate was lower in the vitamin E blended HXLPE cup (0.028 mm/year) compared with the UHMWPE cup (0.035 mm/year) (p = 0.002). No adverse reactions associated with the clinical application of vitamin E blended HXLPE were observed. 15 complications occurred, equally distributed between the two cups. The 6-year survival to revision rate was 98% for both cups. There was no aseptic loosening. Interpretation - This study shows the superior performance of the HXLPE blended with vitamin E acetabular cup with clinical and radiographic results similar to the UHMWPE acetabular cup.
Collapse
Affiliation(s)
- Julie R A Massier
- Clinical Orthopedic Research Center – mN, Zeist,Department of Orthopedic Surgery, Diakonessenhuis, Utrecht, the Netherlands
| | - Joost H J Van Erp
- Clinical Orthopedic Research Center – mN, Zeist,Department of Orthopedic Surgery, Diakonessenhuis, Utrecht, the Netherlands,Correspondence:
| | | | - Arthur DE Gast
- Clinical Orthopedic Research Center – mN, Zeist,Department of Orthopedic Surgery, Diakonessenhuis, Utrecht, the Netherlands
| |
Collapse
|
7
|
van Erp JHJ, Massier JRA, Halma JJ, Snijders TE, de Gast A. 2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene. Acta Orthop 2020; 91:254-259. [PMID: 32098534 PMCID: PMC8023900 DOI: 10.1080/17453674.2020.1730073] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The long-term survival of arthroplasty components may be limited by polyethylene wear-related problems such as periprosthetic osteolysis and aseptic loosening. Highly cross-linked polyethylene (HXLPE) blended with vitamin E was introduced to improve oxidative stability and to avoid long-term embrittlement. This study clinically compares the tribological behavior and clinical outcome of vitamin E blended HXLPE with ultra-high molecular weight polyethylene (UHMWPE) in an isoelastic monoblock cup for uncemented total hip arthroplasty.Patients and methods - In this randomized controlled trial (RCT), 199 patients were included: 102 patients received the vitamin E blended HXLPE cup, 97 patients the UHMWPE cup. Clinical and radiographic parameters were obtained preoperatively, directly postoperative and at 3, 12, and 24 months. Wear rates were compared using the mean linear femoral head penetration (FHP) rate.Results - 188 patients (94%) completed the 2-year follow-up. Mean patient satisfaction was higher in the vitamin E blended HXLPE group (8.9 [1]) than in in the control group (8.5 [2], p = 0.03). The Harris Hip Score (HHS) was higher in the vitamin E blended HXLPE group (95 [8]) than in the control group (92 [11], p = 0.3). The FHP rate was lower in the vitamin E blended HXLPE group: 0.046 mm/year compared with 0.056 mm/year in the control group (p = 0.05). No adverse reactions associated with the clinical application of vitamin E blended HXLPE were observed during follow-up, with an excellent 2-year survival to revision rate of 98% for both cups.Interpretation - This study shows the superior performance of the HXLPE blended with vitamin E acetabular cup with lower linear femoral head penetration rates and better clinical results compared with the UHMWPE acetabular cup after 2 years.
Collapse
Affiliation(s)
- Joost H J van Erp
- Clinical Orthopedic Research Center—mN, Zeist, the Netherlands; ,Department of Orthopedic Surgery, Diakonessenhuis, Utrecht, the Netherlands,Correspondence::
| | - Julie R A Massier
- Clinical Orthopedic Research Center—mN, Zeist, the Netherlands; ,Department of Orthopedic Surgery, Diakonessenhuis, Utrecht, the Netherlands
| | - Jelle J Halma
- Clinical Orthopedic Research Center—mN, Zeist, the Netherlands;
| | - Thom E Snijders
- Clinical Orthopedic Research Center—mN, Zeist, the Netherlands;
| | - Arthur de Gast
- Clinical Orthopedic Research Center—mN, Zeist, the Netherlands; ,Department of Orthopedic Surgery, Diakonessenhuis, Utrecht, the Netherlands
| |
Collapse
|
8
|
The Survivorship of the Uncemented Iso-Elastic Monoblock Acetabular Component at a Mean of 6-Year Follow-up. HSS J 2020; 16:15-22. [PMID: 32015736 PMCID: PMC6973989 DOI: 10.1007/s11420-018-09658-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2018] [Accepted: 11/22/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Aseptic loosening, caused by wear and osteolysis, is the most frequent reason for hip replacement revision in the UK. To prevent aseptic loosening, an acetabular component with vitamin E added to irradiated highly cross-linked polyethylene (HXLPE) was developed to reduce oxidative degradation. QUESTIONS/PURPOSES A prior study of the vitamin E-blended HXLPE acetabular component after 2 years of follow-up reported no adverse reactions or abnormal mechanical behavior. To further examine this hypothesis of reducing wear and osteolysis, we sought to evaluate outcomes after 6-year follow-up. METHODS A cohort of 95 of the 112 initial patients (84.2%) completed the 6 years of follow-up after receiving a vitamin E-blended HXLPE acetabular component. Evaluation was performed in terms of clinical (visual analog scale [VAS] score, VAS score with weight-bearing, VAS score for satisfaction, and Harris Hip Score) and radiological (inclination, polar gap, radiolucencies, migration, and 2-D linear femoral head penetration rate) assessment. RESULTS The mean VAS score for patient satisfaction was 8.75 and the mean Harris Hip Score was 91.8. There were two revisions because of deep infections and one because of a peri-prosthetic femoral fracture. Two acetabular components migrated initially; however, delayed acetabular stabilization occurred. Both patients had good clinical scores at 72 months. The mean femoral head penetration rate was 0.036 mm/year. CONCLUSIONS This prospective cohort study has shown no adverse reactions concerning the vitamin E additive, promising wear rates, no signs of osteolysis, a 100% survival rate for aseptic loosening, and an all-cause survivorship percentage of 97.4% at 6 years of follow-up.
Collapse
|
9
|
Lambert B, Neut D, van der Veen HC, Bulstra SK. Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature. INTERNATIONAL ORTHOPAEDICS 2018; 43:1549-1557. [PMID: 30470866 DOI: 10.1007/s00264-018-4237-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Accepted: 11/14/2018] [Indexed: 02/04/2023]
Abstract
Highly cross-linked ultrahigh molecular weight polyethylene (UHMWPE) was introduced to decrease wear debris and osteolysis. During cross-linking, free radicals are formed, making highly cross-linked polyethylene vulnerable to oxidative degradation. In order to reduce this process, anti-oxidant vitamin E can be incorporated in polyethylene. This review provides an overview of the effects of vitamin E incorporation on major complications in total joint arthroplasty: material failure due to oxidative degradation, wear debris and subsequent periprosthetic osteolysis, and prosthetic joint infections. Secondly, this review summarizes the first clinical results of total hip and knee arthroplasties with vitamin E incorporated highly cross-linked polyethylene. Based on in vitro studies, incorporation of vitamin E in polyethylene provides good oxidative protection and preserves low wear rates. Incorporation of vitamin E may have the beneficial effect of reduced inflammatory response to its wear particles. Some microorganisms showed reduced adherence to vitamin E-incorporated UHMWPE; however, clinical relevance is doubtful. Short-term clinical studies of total hip and knee arthroplasties with vitamin E-incorporated highly cross-linked UHMWPE reported good clinical results and wear rates similar to highly cross-linked UHMWPE without vitamin E.
Collapse
Affiliation(s)
- Bart Lambert
- Department of Orthopedic Surgery, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands
| | - Daniëlle Neut
- Department of Biomedical Engineering, University of Groningen, University Medical Center Groningen, Antonius Deusinglaan 1, 9713 AV, Groningen, The Netherlands
| | - Hugo C van der Veen
- Department of Orthopedic Surgery, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.
| | - Sjoerd K Bulstra
- Department of Orthopedic Surgery, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands
| |
Collapse
|