1
|
Heimann AF, Gautier E, Schwab JM, Wahl P, Tannast M, Levrat E, Raabe I. Metallosis-Induced Warm Antibody Auto-Immune Hemolytic Anemia After Bilateral, Large-Diameter Metal-on-Metal Total Hip Arthroplasty With Complete Remission After Revision. Arthroplast Today 2024; 29:101471. [PMID: 39185399 PMCID: PMC11342758 DOI: 10.1016/j.artd.2024.101471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Revised: 06/21/2024] [Accepted: 06/24/2024] [Indexed: 08/27/2024] Open
Abstract
The use of metal-on-metal bearing couples in total hip arthroplasty can lead to an increased release of metal ions, particularly cobalt and chromium over time. This can lead to local and systemic metallosis, which has cytotoxic, genotoxic, and immunotoxic effects and can cause a host of secondary disorders. We describe the case of a 37-year-old female patient that was diagnosed with warm-antibody autoimmune hemolytic anemia (WAIHA) one and a half years after bilateral large-diameter head metal-on-metal total hip arthroplasty. For 11 years, it was refractory to all therapy, including splenectomy and rituximab, requiring long-term oral prednisone for disease control. Ultimately, systemic metallosis and periprosthetic joint infection were diagnosed, requiring explantation of the prostheses. By the sixth week postoperatively, she experienced complete spontaneous remission of her WAIHA. In conclusion, WAIHA can be associated with systemic metallosis in patients with metal-on-metal prosthetic joint replacements. Both hematologists and orthopedic surgeons should be aware of this.
Collapse
Affiliation(s)
- Alexander Frank Heimann
- Department of Orthopaedic Surgery and Traumatology, HFR Fribourg – Cantonal Hospital, University of Fribourg, Fribourg, Switzerland
| | - Emanuel Gautier
- Department of Orthopaedic Surgery and Traumatology, HFR Fribourg – Cantonal Hospital, University of Fribourg, Fribourg, Switzerland
| | - Joseph M. Schwab
- Department of Orthopaedic Surgery and Traumatology, HFR Fribourg – Cantonal Hospital, University of Fribourg, Fribourg, Switzerland
| | - Peter Wahl
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
- Faculty of Medicine, University of Berne, Berne, Switzerland
| | - Moritz Tannast
- Department of Orthopaedic Surgery and Traumatology, HFR Fribourg – Cantonal Hospital, University of Fribourg, Fribourg, Switzerland
| | - Emmanuel Levrat
- Department of Hematology, HFR Fribourg – Cantonal Hospital, University of Fribourg, Fribourg, Switzerland
| | - Ines Raabe
- Department of Orthopaedic Surgery and Traumatology, HFR Fribourg – Cantonal Hospital, University of Fribourg, Fribourg, Switzerland
| |
Collapse
|
2
|
Sheridan GA, Neufeld ME, Sidhu A, Kurmis AP, Kelly M, O'Byrne JM, Howard LC, Masri BA, Garbuz DS. The Diagnostic Utility of Serum Metal Ion Markers for High-Grade Aseptic Lymphocyte-Dominated Vasculitis-Associated Lesions (ALVALs) in Revision Hip and Knee Arthroplasty: An International Multicenter Study. J Arthroplasty 2024; 39:206-210. [PMID: 37331438 DOI: 10.1016/j.arth.2023.06.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 06/07/2023] [Accepted: 06/09/2023] [Indexed: 06/20/2023] Open
Abstract
BACKGROUND Aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) are typically described in the context of metal-on-metal (MoM) hip bearings. This study explores the diagnostic utility of preoperative serum cobalt and chromium ion levels in determining the histological grade of ALVAL in revision hip and knee arthroplasty. METHODS This was a multicenter retrospective review of 26 hips and 13 knees assessing the correlation between preoperative ion levels (mg/L (ppb)) and the histological grade of ALVAL from intraoperative specimens. The diagnostic ability of preoperative serum cobalt and chromium levels to determine high-grade ALVAL was assessed using a receiver operating characteristic (ROC) curve. RESULTS In the knee cohort, there was a higher serum cobalt level in high-grade ALVAL cases (10.2 mg/L (ppb) versus 3.1 mg/L (ppb)) (P = .0002). The Area Under the Curve (AUC) was 1.00 (95% confidence interval (CI) 1.00 to 1.00). There was a higher serum chromium level in high-grade ALVAL cases (12.25 mg/L (ppb) versus 7.77 mg/L (ppb)) (P = .0002). The AUC was 0.806 (95% CI 0.555 to 1.00). In the hip cohort, there was a higher serum cobalt level in high-grade ALVAL cases (333.5 mg/L (ppb) versus 119.9 mg/L (ppb)) (P = .0831). The AUC was 0.619 (95% CI 0.388 to 0.849). There was a higher serum chromium level in high-grade ALVAL cases (186.4 mg/L (ppb) versus 79.3 mg/L (ppb)) (P = .183). The AUC was 0.595 (95% CI 0.365 to 0.824). CONCLUSIONS Histologically, high-grade ALVAL has significantly higher preoperative serum cobalt and chromium ion levels in revision TKA. Preoperative serum ion levels have excellent diagnostic utility in revision TKA. Cobalt levels in revision THA have a fair diagnostic ability and chromium levels had a poor diagnostic ability.
Collapse
Affiliation(s)
- Gerard A Sheridan
- Department of Orthopaedics, University of British Columbia, Vancouver, Canada
| | - Michael E Neufeld
- Department of Orthopaedics, University of British Columbia, Vancouver, Canada
| | - Arsh Sidhu
- Department of Orthopaedics, University of British Columbia, Vancouver, Canada
| | - Andrew P Kurmis
- Department of Orthopaedic Surgery, Lyell McEwin Hospital, Vale, Elizabeth, SA, Australia
| | - Martin Kelly
- Royal College of Surgeons in Ireland, Dublin, Ireland
| | | | - Lisa C Howard
- Department of Orthopaedics, University of British Columbia, Vancouver, Canada
| | - Bassam A Masri
- Department of Orthopaedics, University of British Columbia, Vancouver, Canada
| | - Donald S Garbuz
- Department of Orthopaedics, University of British Columbia, Vancouver, Canada
| |
Collapse
|
3
|
Bruschetta A, Palco M, Fenga D, Giuca G, Holzer LA, Alito A, Cacciola G, De Meo F, Cavaliere P. How to Manage Metallosis: A Retrospective Cohort Analysis after Revision Hip Surgery. J Clin Med 2023; 12:4809. [PMID: 37510924 PMCID: PMC10381485 DOI: 10.3390/jcm12144809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 07/13/2023] [Accepted: 07/17/2023] [Indexed: 07/30/2023] Open
Abstract
BACKGROUND Adverse local tissue reactions to metal debris are due to a metal-on-metal bearing complication caused by micromotions at modular interfaces that induce corrosion of the protective oxide layer. This process could lead to wear, fretting, and abrasion with the release of metal ions locally and systemically, which may cause adverse local reactions in nearby tissues. The aim of this study is to describe a series of patients with painful local adverse tissue reactions secondary to corrosion at the modular neck-body interface, to document the clinical presentation, diagnostic workup, and surgical findings of our research, and to search for a possible correlation between metallosis and infection. METHODS A retrospective study of patients with adverse local tissue reactions due to metal surface corrosion was performed. Blood samples were collected to identify erythrocyte sedimentation rate, C reactive protein, and procalcitonin, and a magnetic resonance imaging protocol was performed. RESULTS Serum cobalt and chromium levels of the 43 patients tested were significantly higher on average. However, both erythrocyte sedimentation rate and C-reactive protein were significantly elevated. Magnetic resonance imaging showed adverse reactions to metal debris with large soft tissue masses and surrounding tissue damage. CONCLUSIONS Corrosion in hip prosthesis can lead to the release of metal ions and debris locally and systemically, resulting in local soft tissue changes. A "tumor-like" debridement can reduce this complication.
Collapse
Affiliation(s)
| | - Michelangelo Palco
- Department of Orthopaedic and Traumatology, Casa di Cura Caminiti, 89018 Villa San Giovanni, Italy
| | - Domenico Fenga
- Section of Orthopaedics and Traumatology, Department of Biomedical Sciences and Morphological and Functional Images, University of Messina, 98122 Messina, Italy
| | - Gabriele Giuca
- Section of Orthopaedics and Traumatology, Department of Biomedical Sciences and Morphological and Functional Images, University of Messina, 98122 Messina, Italy
| | - Lukas A Holzer
- Perth Orthopaedic and Sports Medicine Centre, Perth, WA 6005, Australia
| | - Angelo Alito
- Department of Biomedical, Dental Sciences and Morphological and Functional Images, University of Messina, 98122 Messina, Italy
| | - Giorgio Cacciola
- Orthopaedic Institute of Southern Italy "Franco Scalabrino", 98165 Messina, Italy
| | - Federico De Meo
- Orthopaedic Institute of Southern Italy "Franco Scalabrino", 98165 Messina, Italy
| | - Pietro Cavaliere
- Orthopaedic Institute of Southern Italy "Franco Scalabrino", 98165 Messina, Italy
| |
Collapse
|
4
|
Daji AV, Workman KK, Yoo CJ, Smith CN, Kumar D, Weber MA, Snyder MJ, Urish KL. Risk Stratification and Pain Outcomes Following Revision Total Hip Arthroplasty for Adverse Local Tissue Reactions. J Arthroplasty 2022; 37:2406-2411. [PMID: 35738363 DOI: 10.1016/j.arth.2022.06.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 06/10/2022] [Accepted: 06/14/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Revision total hip arthroplasty (THA) for adverse local tissue reactions (ALTRs) secondary to head-neck taper corrosion is associated with a high complication rate. Diagnosis of ALTR is based on risk stratification using the patient's history and examination, implant risk, serum metal ion levels, and imaging. The purpose of this study was to determine if stratification using similar risk factors is predictive of outcomes following revision THA for metal-on-polyethylene (MoP) ALTR. METHODS We performed a retrospective review on 141 patients revised for ALTR due to head-neck taper corrosion. Pain outcomes following surgery were analyzed using a generalized linear mixed model. Complications were defined as instability/dislocation, infection, fracture, nerve palsy, leg-length discrepancy, or reoperation. RESULTS The overall complication rate was 17.7%. The odds of having pain decreased by 44% after revision surgery (Odds Ratio = 0.56, 95% Confidence Interval: 0.324 to 0.952). There was no significant difference in instability/dislocation based on either increased or decreased head-neck offset (P = .67) or magnetic resonance imaging findings of abductor loss, effusion size, and degree of ALTR (P = .73). Increased serum cobalt (P = .31) and chromium (P = .08) levels did not predict complications; however, a decreased cobalt-chromium ratio was associated with postoperative complications (2.8 versus 3.5; P = .002). CONCLUSION These findings are the first to suggest that patients who have ALTR after MoP THA undergoing revision surgery demonstrated major pain relief. Increasing femoral head offset did not change rates of instability/dislocation. In clinical scenarios where preoperative cobalt-chromium femoral head offsets were greater than available ceramic head offsets, a mandatory decrease in femoral head offset did not increase rates of instability/dislocation.
Collapse
Affiliation(s)
- Akshay V Daji
- Department of Orthopaedic Surgery, HCA Florida JFK/University of Miami Miller School of Medicine, Palm Beach, Florida
| | - Kalain K Workman
- Department of Orthopaedic Surgery, University of Pittsburgh Medical Center-Pinnacle, Harrisburg, Pennsylvania
| | - Charlie J Yoo
- Department of Orthopaedic Surgery, University of Pittsburgh Medical Center-Pinnacle, Harrisburg, Pennsylvania
| | - Clair N Smith
- Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania
| | - Deepak Kumar
- Department of Internal Medicine, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania
| | - Margaret A Weber
- Department of Pediatrics, University of Minnesota, Minneapolis, Minnesota
| | - Matthew J Snyder
- Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Kenneth L Urish
- Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania; Arthritis and Arthroplasty Design Lab, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Department of Bioengineering, Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, Pennsylvania
| |
Collapse
|
5
|
Ilo KC, Hothi HS, Skinner JA, Hart AJ. Metal-on-metal total hip arthroplasty: does increasing modularity affect clinical outcome? Hip Int 2022; 32:677-684. [PMID: 33322929 DOI: 10.1177/1120700020979275] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Modularity of metal-on-metal (MoM) implants has come under scrutiny due to concerns regarding additional sources of metal debris. This study is a retrieval analysis of implants from the same manufacturer with the same MoM bearing surface. The difference between the implants was presence or absence of modular junctions. METHODS This is a retrospective study of 31 retrieved implants from 31 patients who received a Conserve Wright Medical MoM hip prosthesis. The 31 implants consisted of 16 resurfacings and 15 implants with modular junctions; 4 conventional THAs and 11 modular-neck THAs. RESULTS 43% of pre-revision MRI scans performed on resurfacing implants and 91% performed on the modular implants illustrated evidence of an adverse local tissue reaction. There was no difference in pre-revision blood metal ion levels or bearing surface wear between the resurfacings and modular implants. The neck-head tapers of the modular group showed low levels of material loss. However, the neck-stem tapers showed increased severity of corrosion and material loss. CONCLUSIONS The modular implants had an increased incidence of adverse local tissue reaction. This could be related to the presence of modular junctions, particular the neck-stem junction which showed increased susceptibly to corrosion.
Collapse
Affiliation(s)
- Kevin C Ilo
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, UK
| | - Harry S Hothi
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, UK
| | - John A Skinner
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, UK
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, UK
| |
Collapse
|
6
|
Radice S, Neto MQ, Fischer A, Wimmer MA. Nickel-free high-nitrogen austenitic steel outperforms CoCrMo alloy regarding tribocorrosion in simulated inflammatory synovial fluids. J Orthop Res 2022; 40:1397-1408. [PMID: 34449923 PMCID: PMC8882197 DOI: 10.1002/jor.25174] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 07/13/2021] [Accepted: 08/13/2021] [Indexed: 02/04/2023]
Abstract
CoCrMo alloys are well-established biomaterials used for orthopedic joint replacement implants. However, such alloys have been associated with clinical problems related to wear and corrosion. A new generation of austenitic high-nitrogen steels (AHNSs) has been developed for biomedical applications. Here, we have addressed influences of hyaluronic acid, combined with inflammatory (oxidizing) conditions, on tribocorrosion of the high-nitrogen FeCrMnMoN0.9 steel (DIN/EN X13CrMnMoN18-14-3, 1.4452), and of the low carbon CoCrMo0.03 alloy (ISO 5832-12). We aimed to elucidate critical and clinically relevant conditions affecting the implant's performance in certain orthopedic applications. Tribocorrosion tests were conducted in triplicate, with discs under reciprocating sliding wear against a ceramic ball. Different lubricants were prepared from standardized bovine serum solution (ISO 14242-1), with variable additions of hyaluronic acid (HA) and hydrogen peroxide (H2 O2 ). Test conditions were: 37°C, 86,400 cycles, 37 N load (20-40 MPa after run-in phase). Volumetric wear was quantified; surfaces were evaluated by electrochemical parameters and microscopy/spectroscopy analyses (SEM/EDS). Factorial analysis of variance tests was conducted to examine the effects of HA, H2 O2 , and test material on wear- and corrosion-related dependent variables. Tribocorrosion performances of CoCrMo0.03 and FeCrMnMoN0.9 were comparable in fluids without H2 O2 . With higher H2 O2 concentrations, tribocorrosion increased for CoCrMo0.03 , while this was not the case for FeCrMnMoN0.9 . HA significantly enhanced wear of CoCrMo0.03 in the absence of H2 O2 , while it mitigated the tribocorrosive action of 3 mM H2 O2 ; HA had no impact on FeCrMnMoN0.9 . These results indicate a favorable performance of FeCrMnMoN0.9 compared to CoCrMo0.03 , and encourage further research on AHNS for certain orthopedic applications.
Collapse
Affiliation(s)
- Simona Radice
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| | - Mozart Q. Neto
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| | - Alfons Fischer
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| | - Markus A. Wimmer
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| |
Collapse
|
7
|
Ishida T, Tateiwa T, Takahashi Y, Nishikawa Y, Shishido T, Masaoka T, Yamamoto K. Adverse Tissue Reactions and Metal Ion Behavior After Small-Head Metasul Hip Arthroplasty: A Long-Term Follow-Up Study. Orthop Surg 2021; 14:264-273. [PMID: 34910382 PMCID: PMC8867442 DOI: 10.1111/os.13125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 05/10/2021] [Accepted: 06/03/2021] [Indexed: 11/29/2022] Open
Abstract
Objective To investigate the long‐term survivorship, incidence of adverse reactions to metal debris (ARMD), and metal ion behavior in patients who underwent small‐head Metasul metal‐on‐metal (MoM) total hip arthroplasty (THA). Methods Between February 1998 and September 2003, a retrospective study was performed on 43 consecutive patients (43 hips) who underwent unilateral cementless Metasul MoM THAs at our institution. Of them, 35 patients (nine males and 26 females) who were available for follow‐up more than 15 years after THA were enrolled in this study and underwent metal artifact reduction sequence magnetic resonance imaging (MARS‐MRI) to identify ARMD. The mean age at surgery of the patients was 59.7 years old (range, 31–83). Clinical and radiographic outcomes were evaluated retrospectively. Clinical examinations were conducted using the Harris Hip Score (HHS). Serum cobalt (Co) and chromium (Cr) ion levels and Co/Cr ratio were assessed at different postoperative periods of <5, 5–10, 11–14, and ≥15 years. Results The mean follow‐up period for the 35 patients included was 18.1 years (range, 15–22). The mean HHS significantly improved from 44.6 ± 11.3 points preoperatively to 89.4 ± 7.9 points at the final follow‐up (P < 0.0001). ARMD was found in 20% of the patients using MARS‐MRI. No signs of stem loosening were found clinically or radiographically, whereas cup loosening and ARMD were observed in three patients (9%), for whom revision THAs were performed. The Kaplan–Meier survival rates with revision for any reason as the endpoint were 90.9% at 5 years, 84.8% at 10 years, 84.8% at 15 years (95% CI, 67.1–93.6), and 70.3% at 20 years (95% CI, 43.6–87.0). The survival rates with revision for ARMD as the endpoint were 100% at 5 years, 96.6% at 10 years, 96.6% at 15 years (95% CI, 77.2–99.7), and 80.1% at 20 years (95% CI, 45.3–95.2). Serum Co ion level peaked at 5–10 years after THA, which was significantly higher than that <5 years; however, it decreased to the initial level after 15 years. In contrast, serum Cr ion level significantly increased at 5–10 years and then remained almost constant. Significant differences in Cr ion levels (1.0 vs 2.0 μg/L, P = 0.024) and Co/Cr ratio (1.3 vs 0.9, P = 0.037) were found between non‐ARMD and ARMD patients at >11 years postoperatively. Conclusion Our results suggest that increased Cr ion levels and decreased Co/Cr ratio may be signs of ARMD in patients who underwent small‐head Metasul MoM THA.
Collapse
Affiliation(s)
- Tsunehito Ishida
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Toshiyuki Tateiwa
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Yasuhito Takahashi
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan.,Department of Bone and Joint Biomaterial Research, Tokyo Medical University, Tokyo, Japan
| | - Yohei Nishikawa
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Takaaki Shishido
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Toshinori Masaoka
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Kengo Yamamoto
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| |
Collapse
|
8
|
Whole blood chromium concentration is very rarely elevated independently of whole blood cobalt. Sci Rep 2021; 11:12352. [PMID: 34117287 PMCID: PMC8196186 DOI: 10.1038/s41598-021-91512-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Accepted: 05/19/2021] [Indexed: 11/21/2022] Open
Abstract
Due to the risk of adverse reactions to metal debris resulting from increased wear of the arthroplasty more than one million metal-on-metal (MoM) hip replacements worldwide are in active follow-up. Follow-up usually includes measurement of both whole blood cobalt (Co) and chromium (Cr) concentrations. Our experience is that Cr is seldom independently elevated. We wanted to ascertain whether blood Cr measurements could be omitted from follow-up protocols without lowering the quality of follow-up. We identified 8438 whole blood Co and Cr measurements performed without or prior to revision surgery. When the cut-off levels 5 µg/L and 7 µg/L were used, Cr was independently elevated in only 0.5% (95% confidence interval, CI, 0.3 to 0.6) and 0.2% (CI 0.1 to 0.3) of the measurements. The models with continuous variables showed that the higher the blood metal concentrations are the lower the percentage of measurements with Cr higher than Co. Our results suggest that whole blood Cr is very rarely independently elevated and therefore the authorities should consider omitting Cr measurements from their screening guidelines of MoM hip replacements. We believe this change in practice would simplify follow-up and lead to cost savings without decreasing the quality of follow-up.
Collapse
|
9
|
Hastie GR, Collinson SC, Aqil A, Basu S, Temperley DE, Board TN, Wynn-Jones H. Study to Assess the Rate of Adverse Reaction to Metal Debris in Hip Resurfacing at a Minimum 13-year Follow-up. J Arthroplasty 2021; 36:1055-1059. [PMID: 33183915 DOI: 10.1016/j.arth.2020.09.056] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 09/28/2020] [Accepted: 09/30/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Hip Resurfacing (HR), although reducing in popularity, is still used in the younger male population. Excellent medium-term results have been published; however, the use of metal on metal has reduced with increased awareness of adverse reactions to metal debris (ARMD). ARMD has been shown to often be clinically "silent" following large Head MoM total hip replacement (THR). The purpose of our study was to report the incidence of ARMD following HR with a minimum follow-up of 13 years. METHODS We performed a retrospective study of a consecutive series of patients who underwent HR between January 1, 2000 and August 1, 2005. All patients were entered into our hospital MoM hip replacement surveillance program database. Patients were reviewed yearly for symptoms and blood ion levels. Patients had Magnetic Resonance (MR) imaging to assess for ARMD. RESULTS A total of 102 patients with 123 hip replacements were included in the study. Eight hips in 7 patients were revised: two for fracture, one for avascular necrosis, and five for ARMD. A best-case scenario of 109 (93.2%) resurfacings were surviving at 13 years. With regard to the radiological analysis, 34% were found to have ARMD on MR. CONCLUSION While the implant survivorship in our series is acceptable, we found a high incidence of ARMD. Surgeons and patients with or considering a HR should be aware of the risk of ARMD developing. This allows an informed choice as to the best implant for their personal requirement and informs of the potential modes of failure and need for long-term screening.
Collapse
Affiliation(s)
- Graham R Hastie
- Wigan and Leigh NHS Trust, Wrightington Hospital, Wigan, United Kingdom, WN6 9EP
| | - Sophie C Collinson
- Wigan and Leigh NHS Trust, Wrightington Hospital, Wigan, United Kingdom, WN6 9EP
| | - Adeel Aqil
- Wigan and Leigh NHS Trust, Wrightington Hospital, Wigan, United Kingdom, WN6 9EP
| | - Subhasis Basu
- Wigan and Leigh NHS Trust, Wrightington Hospital, Wigan, United Kingdom, WN6 9EP
| | - David E Temperley
- Wigan and Leigh NHS Trust, Wrightington Hospital, Wigan, United Kingdom, WN6 9EP
| | - Timothy N Board
- Wigan and Leigh NHS Trust, Wrightington Hospital, Wigan, United Kingdom, WN6 9EP
| | - Henry Wynn-Jones
- Wigan and Leigh NHS Trust, Wrightington Hospital, Wigan, United Kingdom, WN6 9EP
| |
Collapse
|
10
|
Bozza N, Guindani N, Pezzotta G, Alberto F, Castelli CC. 15-year follow-up of MoM 36-mm THA: clinical, laboratory, and radiological (CT and MRI) prospective assessment. Hip Int 2020; 30:42-51. [PMID: 33267695 DOI: 10.1177/1120700020971662] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION There is limited knowledge of the long-term results of metal-on-metal total hip arthroplasty (MoM THA), particularly concerning adverse local tissue reaction (ALTR), Co/Cr ions level and revision rate. Even if MoM bearing surfaces are no longer used, long-term data could help in defining the course and best management for these patients. The purpose of this study is to investigate the clinical outcomes, describe radiological findings including CT metal artefact reduction algorithm for orthopaedic implants (O-MAR) and MRI multi acquisition variable resonance image combination (MAVRIC) in 36-mm MoM THA. METHODS In this long-term prospective study, 46 consecutive patients with primary MoM THA (mono- or bilateral) were enrolled between 2004 and 2005. Pinnacle acetabular cup, Summit cementless stem with 36-mm metal head and Ultamet CoCr alloy liner (Depuy Inc.) were implanted, in the same centre by the same senior surgeon. Patients were reviewed at 5-, 10- and 15-years, including Co/Cr levels and standard radiographs at every follow-up, whilst the 15-year follow-up included hip sonography, MRI MAVRIC and CT O-MAR. RESULTS At 15 years, the overall survival rate of the implants (both stems and cups) was 83% (30/36). Revisions were performed in 9% (4/46) because of ALTR, 2% (1/46) septic loosening and 2% periprosthetic fracture. Both Cr and Co concentration increased over time, even though remaining at low level risk at 15 years: Co from 0.11 (+/- 0.18) to 4.29 (+/- 3.26) and Cr from 0.38 (+/- 0.32) to 1.37 (+/- 1.15). Functional scores in non-revised patients showed good to excellent results in more than 90%. Engh-score correlated with time from surgery (p = 0.017) and with sonographic, CT and RM findings (p < 0.05). Concordance has been found between CT and MRI findings (sign-rank test, p = 0.241; Intraclass Correlation Coefficients 0.987); however, no specific MRI or CT lesion patterns could be recognised among symptomatic and non-symptomatic patients. DISCUSSION The long-term rate of ALTR after 36-mm MoM THA was comparable with previous studies; a regular follow-up for those implants is mandatory. During follow-up Co-Cr levels increased over time and radiography was a suitable screening technique; the Engh score in particular, proved to be a reliable assessment tool. CT O-MAR and MRI with MAVRIC protocols may add valuable data in clinical practice, although MRI is significantly more efficient than CT in the identification of ALTR lesions, peri-articular effusion and in the evaluation of soft tissues.
Collapse
Affiliation(s)
- Nicola Bozza
- Surgical Department, Orthopaedics and Traumatology, Papa Giovanni XXIII Hospital, Bergamo, Italy
| | - Nicola Guindani
- Surgical Department, Orthopaedics and Traumatology, Papa Giovanni XXIII Hospital, Bergamo, Italy
| | - Giuseppe Pezzotta
- Surgical Department, Orthopaedics and Traumatology, Papa Giovanni XXIII Hospital, Bergamo, Italy
| | - Ferrari Alberto
- Fondazione per la Ricerca Ospedale di Bergamo (FROM), Bergamo, Italy
| | - Claudio C Castelli
- Surgical Department, Orthopaedics and Traumatology, Papa Giovanni XXIII Hospital, Bergamo, Italy
| |
Collapse
|
11
|
Chang JS, Haddad FS. Revision total hip arthroplasty for metal-on-metal failure. J Clin Orthop Trauma 2020; 11:9-15. [PMID: 32001977 PMCID: PMC6985013 DOI: 10.1016/j.jcot.2019.09.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 09/26/2019] [Indexed: 12/12/2022] Open
Abstract
Metal-on-metal (MoM) arthroplasty systems became popular in the early-2000s due to presumed advantages of improved wear characteristics and superior stability. However, subsequent reports of abnormal soft-tissue reactions to MoM implants and national registry data reporting high failure rates raised concerns. Early outcomes of revision total hip arthroplasty (THA) for adverse reaction to metal debris (ARMD) were poor, leading to development of surveillance programs and a trend towards early revision surgery. Patients with MoM arthroplasties require surveillance, comprehensive history and physical examination, imaging with ultrasound or magnetic resonance imaging (MRI), and laboratory evaluation including metal ion levels. Operative strategies for revision THA vary from exchange of modular components to extensive debridement and reconstruction with revision components. Surgeons should be aware of the increased risks of dislocation and infection following revision THA for ARMD. However, there is growing evidence that early revision surgery prior to extensive soft tissue destruction results in improved outcomes and decreased re-operation rates. It is estimated that >1 million MoM articulations have been implanted, with a large proportion still in situ. It is imperative to understand the aetiology, presentation, and management strategies for these patients to optimise their clinical outcomes.
Collapse
Affiliation(s)
- Justin S. Chang
- Department of Trauma and Orthopaedic Surgery, University College London Hospitals, 250 Euston Road, NW1 2PG, London, UK,Corresponding author.
| | - Fares S. Haddad
- Department of Trauma and Orthopaedic Surgery, University College London Hospitals, 250 Euston Road, NW1 2PG, London, UK,The Princess Grace Hospital, 42-52 Nottingham Place, W1U 5NY, London, UK
| |
Collapse
|
12
|
Goodman SB, Gallo J, Gibon E, Takagi M. Diagnosis and management of implant debris-associated inflammation. Expert Rev Med Devices 2020; 17:41-56. [PMID: 31810395 PMCID: PMC7254884 DOI: 10.1080/17434440.2020.1702024] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Accepted: 12/04/2019] [Indexed: 02/07/2023]
Abstract
Introduction: Total joint replacement is one of the most common, safe, and efficacious operations in all of surgery. However, one major long-standing and unresolved issue is the adverse biological reaction to byproducts of wear from the bearing surfaces and modular articulations. These inflammatory reactions are mediated by the innate and adaptive immune systems.Areas covered: We review the etiology and pathophysiology of implant debris-associated inflammation, the clinical presentation and detailed work-up of these cases, and the principles and outcomes of non-operative and operative management. Furthermore, we suggest future strategies for prevention and novel treatments of implant-related adverse biological reactions.Expert opinion: The generation of byproducts from joint replacements is inevitable, due to repetitive loading of the implants. A clear understanding of the relevant biological principles, clinical presentations, investigative measures and treatments for implant-associated inflammatory reactions and periprosthetic osteolysis will help identify and treat patients with this issue earlier and more effectively. Although progressive implant-associated osteolysis is currently a condition that is treated surgically, with further research, it is hoped that non-operative biological interventions could prolong the lifetime of joint replacements that are otherwise functional and still salvageable.
Collapse
Affiliation(s)
- Stuart B. Goodman
- Department of Orthopaedic Surgery, Stanford University, Redwood City, CA, USA
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Jiri Gallo
- Department of Orthopaedics, Palacký University Olomouc, Olomouc, Czech Republic
| | - Emmanuel Gibon
- Department of Orthopaedic Surgery, University of Florida, Gainesville, FL, USA
| | - Michiaki Takagi
- Department of Orthopaedic Surgery, Yamagata University, Yamagata, Japan
| |
Collapse
|
13
|
Moon JK, Kim Y, Hwang KT, Yang JH, Ryu JA, Kim YH. Prevalence and natural course of pseudotumours after small-head metal-on-metal total hip arthroplasty: a minimum 18-year follow-up study of a previous report. Bone Joint J 2019; 101-B:317-324. [PMID: 30813798 DOI: 10.1302/0301-620x.101b3.bjj-2018-1054.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The present study investigated the five-year interval changes in pseudotumours and measured serum metal ions at long-term follow-up of a previous report of 28 mm diameter metal-on-metal (MoM) total hip arthroplasty (THA). PATIENTS AND METHODS A total of 72 patients (mean age 46.6 years (37 to 55); 43 men, 29 women; 91 hips) who underwent cementless primary MoM THA with a 28 mm modular head were included. The mean follow-up duration was 20.3 years (18 to 24). All patients had CT scans at a mean 15.1 years (13 to 19) after the index operation and subsequent follow-up at a mean of 20.2 years (18 to 24). Pseudotumour volume, type of mass, and new-onset pseudotumours were evaluated using CT scanning. Clinical outcomes were assessed by Harris Hip Score (HHS) and the presence of groin pain. Serum metal ion (cobalt (Co) and chromium (Cr)) levels were measured at the latest follow-up. RESULTS At final follow-up, pseudotumours were observed in 26/91 hips (28.6%). There was an increase in volume of the pseudotumour in four hips (15.4%), no change in volume in 21 hips (80.8%), and a decrease in volume in one hip (3.8%). There were no new-onset pseudotumours. There was no significant difference in HHS between patients with and without pseudotumours. At final follow-up, mean serum Co ion levels and median Co:Cr ratios were significantly greater in patients with pseudotumours, but the serum Cr ion levels were not significantly different. CONCLUSION At a mean 20 years of follow-up, pseudotumours were observed in 26/91 hips (28.6%) with no new-onset pseudotumours during subsequent follow-up. Most pseudotumours in small-head MoM THA were static in volume and asymptomatic with normal serum metal ion levels. Cite this article: Bone Joint J 2019;101-B:317-324.
Collapse
Affiliation(s)
- J-K Moon
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| | - Y Kim
- Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea
| | - K-T Hwang
- Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea
| | - J-H Yang
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| | - J-A Ryu
- Department of Radiology, Hanyang University Guri Hospital, Guri, South Korea
| | - Y-H Kim
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| |
Collapse
|