1
|
Gausden EB, Bedard NA, Gililland JM, Haidukewych GJ. What's New in Periprosthetic Femur Fractures? J Arthroplasty 2024; 39:S18-S25. [PMID: 38642853 DOI: 10.1016/j.arth.2024.04.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 04/09/2024] [Accepted: 04/11/2024] [Indexed: 04/22/2024] Open
Abstract
BACKGROUND Periprosthetic femur fracture (PFF) is one of the most common indications for reoperation following total hip arthroplasty. METHODS/RESULTS This article provides a review of a symposium on PFF that was presented at the American Association of Hip and Knee Surgeons 2023 annual meeting, including an overview of the Vancouver classification and its implications on treatment and subsequent complications, an updated approach to the management of intraoperative fractures, and finally, contemporary strategies for both osteosynthesis as well as revision arthroplasty for PFFs. CONCLUSION As the incidence of PPF continues to increase, arthroplasty and trauma surgeons must be prepared to address this challenging complication with a contemporary understanding of the treatment options and their outcomes.
Collapse
Affiliation(s)
- Elizabeth B Gausden
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York
| | | | - Jeremy M Gililland
- Department of Orthopedic Surgery, University of Utah, Salt Lake City, Utah
| | - George J Haidukewych
- Department of Orthopedic Surgery, Orlando Health Medical Group, Orlando, Florida
| |
Collapse
|
2
|
Wilson EJ, Strait AV, Fricka KB, Hamilton WG, Sershon RA. Outcomes Following Intraoperative Calcar Fractures During Cementless Total Hip Arthroplasty. J Arthroplasty 2024; 39:S464-S468. [PMID: 38401616 DOI: 10.1016/j.arth.2024.02.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 02/06/2024] [Accepted: 02/08/2024] [Indexed: 02/26/2024] Open
Abstract
BACKGROUND Intraoperative calcar fractures (IOCFs) are an established complication of cementless total hip arthroplasty (THA). Prompt recognition and management may prevent subsequent postoperative complications. This study aimed to evaluate the outcomes and revision rates of THAs with IOCFs identified and managed intraoperatively. METHODS There were 11,438 primary cementless THAs performed at a single institution from 2009 to 2022. Prospectively collected data on cases with an IOCF was compared to cases without the complication. The fracture group had a lower body mass index (26.9 versus 28.9 kg/m2; P = .01). Patient age, sex, and mean follow-up (3.2 (0 to 12.8) versus 3.5 years (0 to 14); P = .45) were similar between groups. RESULTS An IOCF occurred in 62 of 11,438 (0.54%) cases. The THAs done via a direct anterior approach experienced the lowest rate of fractures (31 of 7,505, 0.4%) compared to postero-lateral (27 of 3,759, 0.7%; P = .03) and lateral (4 of 165, 2.4%; P < .01) approaches. Of the IOCFs, 48 of 62 (77%) were managed with cerclage cabling, 4 of 62 (6.5%) with intraoperative stem design change and cabling, 4 of 62 (6.5%) with restricted weight-bearing, and 6 of 62 (9.7%) with no modification to the standard postoperative protocol. The IOCF group experienced one case of postoperative component subsidence. No subjects in the IOCF cohort required revision, and rates were similar between groups (0 of 62, 0% versus 215 of 11,376, 1.9%; P = .63). Postoperative Hip dysfunction and Osteoarthritis Outcome Score for Joint Replacement scores were comparable (85.7 versus 86.4; P = .80). CONCLUSIONS Cementless THA complicated by IOCF had similar postoperative revision rates and patient-reported outcome measures at early follow-up when compared to patients not experiencing this complication. Surgeons may use these data to provide postoperative counseling on expectations and outcomes following these rare intraoperative events.
Collapse
Affiliation(s)
- Eric J Wilson
- Anderson Orthopaedic Research Institute, Alexandria, Virginia
| | | | - Kevin B Fricka
- Anderson Orthopaedic Research Institute, Alexandria, Virginia
| | | | | |
Collapse
|
3
|
Forlenza EM, Higgins JDD, Keating TC, Berger RA, Della Valle CJ, Sporer SM. Three Differing Methods of Treating Intraoperative Nondisplaced Calcar Fractures Demonstrate Similar Radiographic Stem Subsidence. J Arthroplasty 2024; 39:S254-S258. [PMID: 38537839 DOI: 10.1016/j.arth.2024.03.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 03/14/2024] [Accepted: 03/16/2024] [Indexed: 04/15/2024] Open
Abstract
BACKGROUND Several management strategies have been described to treat intraoperative calcar fractures during total hip arthroplasty (THA), including retaining the primary implant and utilizing cerclage cables (CCs) or switching the implant to one that bypasses the fracture and achieves diaphyseal fixation. However, the radiographic and clinical outcomes of these differing strategies have never been described and compared. METHODS We retrospectively identified 50 patients who sustained an intraoperative calcar fracture out of 9,129 primary total hip arthroplasties (0.55%) performed by one of three surgeons between 2008 and 2022. Each of the three surgeons consistently employed a distinct strategy for the management of these fractures: retention of the primary metaphyseal-engaging implant and placement of CCs; exchange to a modular, tapered-fluted stem (MTF); or exchange to a fully-coated, diaphyseal-engaging stem (FC). Stem subsidence was then evaluated on standing anteroposterior pelvis radiographs at three months and one year postoperatively. Postoperative medical and surgical complication rates were evaluated. RESULTS A total of fifteen patients were treated with CC, 15 with MTF, and 20 with FC. At three-month follow-up, mean stem subsidence was 0.43 ± 0.08 mm, 1.47 ± 0.36 mm, and 0.68 ± 0.39 mm for CC, MTF, and FC cohorts, respectively (P = .323). At one-year, mean stem subsidence was 0.70 ± 0.08 mm, 1.74 ± 0.69 mm, and 1.88 ± 0.90 mm for the CC, MTF, and FC cohorts, respectively (P = .485). Medical complications included 2 venous thromboembolic events (4%) within 90 days of surgery. There were 6 reoperations (12%); 3 (6%) for acute periprosthetic joint infection (all within the FC cohort); 2 (4%) for postoperative periprosthetic fractures (one fracture distal to the stem in the FC cohort and one fracture at the level of the stem in the MTF cohort), and 1 (2%) closed reduction for instability (within the CC cohort). CONCLUSIONS The three described methods of managing intraoperative nondisplaced calcar fractures demonstrated little radiographic stem subsidence; however, the risk of reoperation was much higher than expected.
Collapse
Affiliation(s)
- Enrico M Forlenza
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - John D D Higgins
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Timothy C Keating
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Richard A Berger
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Craig J Della Valle
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Scott M Sporer
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
4
|
Kim JT, Park JW, Go JJ, Jung SH, Park B, Lee YK. What features of stem increase the risk of intraoperative femoral fracture during cementless primary hip arthroplasty? Arch Orthop Trauma Surg 2024:10.1007/s00402-024-05482-4. [PMID: 39126454 DOI: 10.1007/s00402-024-05482-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Accepted: 07/23/2024] [Indexed: 08/12/2024]
Abstract
INTRODUCTION Cementless fixation has become increasingly popular in hip arthroplasty due to its shorter operation time, easier technique, biologic fixation, and avoidance of bone cement implantation syndrome compared to cemented fixation. However, intraoperative periprosthetic femoral fracture (IOPFx) is a disconcerting complication during cementless hip arthroplasty. Our purpose was to identify the features of cementless stem that increase the risk of IOPFx during primary hip arthroplasty. MATERIALS AND METHODS We retrospectively reviewed all 4806 hip arthroplasties that was performed in a single institution from May 2003 to December 2020. Age at the index arthroplasty, sex, body mass index, physical status, ambulatory function, side of the operation, operational history, cause of the index arthroplasty, type of arthroplasty, surgical approach, surgeon, implant information, and events during the operation were investigated. The shoulder geometry and length of stem were also reviewed. The event of interest was narrowed down to IOPFx among various records of intraoperative events. RESULTS We found IOPFx of 2.6% among all the hips operated with cementless stem. In the multivariable analysis, female (OR = 1.52), childhood hip disease (OR = 2.30), stove-pipe femur (OR = 2.43), combined approach (OR = 2.60), and standard length of stem (OR = 1.59) were found to be significant risk factors of IOPFx. CONCLUSIONS In conclusion, a stem with a standard length is significantly associated with risk of IOPFx compared to a shortened stem. These findings highlight the importance of careful consideration in terms of the risk of IOPFx when standard length cementless stem is chosen.
Collapse
Affiliation(s)
- Jung-Taek Kim
- Department of Orthopedic Surgery, Ajou University School of Medicine, Ajou Medical Center, Suwon, Korea
| | - Jung-Wee Park
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam, 463-707, South Korea
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Jong Jin Go
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam, 463-707, South Korea
| | - Se Hee Jung
- Office of Biostatistics, Medical Research Collaborating Center, Ajou Research Institute for Innovative Medicine, Ajou University Medical Center, Suwon-si, South Korea
| | - Bumhee Park
- Office of Biostatistics, Medical Research Collaborating Center, Ajou Research Institute for Innovative Medicine, Ajou University Medical Center, Suwon-si, South Korea
- Department of Biomedical Informatics, Ajou University School of Medicine, Suwon-si, South Korea
| | - Young-Kyun Lee
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam, 463-707, South Korea.
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea.
| |
Collapse
|
5
|
Rocchi C, Di Matteo V, Chiappetta K, Grappiolo G, Loppini M. Results of Utilizing Cerclage Wires in the Management of Intraoperative Vancouver B1 Fractures in Primary Total Hip Arthroplasties: A Retrospective Cohort Investigation into Clinical and Radiographic Outcomes. J Clin Med 2024; 13:819. [PMID: 38337513 PMCID: PMC10856186 DOI: 10.3390/jcm13030819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Revised: 01/25/2024] [Accepted: 01/28/2024] [Indexed: 02/12/2024] Open
Abstract
BACKGROUND Due to an increase in total hip arthroplasties (THAs), the incidence of periprosthetic hip fractures (PPHFs) is forecast to rise considerably in the next decades, with Vancouver B1 fractures (VB1) accounting for one third of total cases. Femur fixation with cerclages (with or without screws) is considered the current treatment option for intraoperative VB1. METHODS The study retrospectively includes data from patients who developed VB1 PPHFs during THAs from 3 December 2020 to 30 November 2022. The primary outcome of this study was to identify the reintervention-free survival rate. The secondary aim was to determine clinical and radiographic assessment at follow-up, based on Harris hip score (HHS) and limb length discrepancy (LLD). RESULTS Thirty-seven patients with a mean age of 60.03 ± 15.49 (22 to 77) years old were included. Overall, the Kaplan-Meier analysis estimated a reoperation-free survival rate of 99% (CI 95%) at 6 months. The mean limb length discrepancy (LLD) improved from -3.69 ± 6.07 (range -27.9 to 2.08) mm to 0.10 ± 0.67 (range -1.07 to 1.20) mm. The mean HHS improved from 42.72 ± 14.37 (range 21.00-96.00) to 94.40 ± 10.32 (range 56.00-100.00). CONCLUSIONS The employment of cerclage wires represents an effective strategy for handling intraoperative VB1 fractures. Level III retrospective cohort study.
Collapse
Affiliation(s)
- Caterina Rocchi
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, 20090 Milan, Italy; (C.R.); (V.D.M.)
| | - Vincenzo Di Matteo
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, 20090 Milan, Italy; (C.R.); (V.D.M.)
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli 8, 00168 Roma, Italy
- Fondazione Livio Sciutto Onlus, Campus Savona, Università degli Studi di Genova, 17100 Savona, Italy;
| | | | - Guido Grappiolo
- Fondazione Livio Sciutto Onlus, Campus Savona, Università degli Studi di Genova, 17100 Savona, Italy;
- IRCCS Humanitas Research Hospital, Rozzano, 20089 Milan, Italy;
| | - Mattia Loppini
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, 20090 Milan, Italy; (C.R.); (V.D.M.)
- Fondazione Livio Sciutto Onlus, Campus Savona, Università degli Studi di Genova, 17100 Savona, Italy;
- IRCCS Humanitas Research Hospital, Rozzano, 20089 Milan, Italy;
| |
Collapse
|
6
|
Parsa A, Chishti Z, Saeed SK, Carbone AD, Domb BG, Schinsky MF. Non-metallic cerclage fixation methods for proximal femoral osteotomy and periprosthetic hip fractures offer promising outcomes: A systematic review. J Orthop 2024; 47:8-17. [PMID: 38046452 PMCID: PMC10689235 DOI: 10.1016/j.jor.2023.11.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 11/10/2023] [Indexed: 12/05/2023] Open
Abstract
Background Periprosthetic femur fracture (PFF) is an important complication to consider in total hip arthroplasty (THA). The purpose of this systematic review was to compare outcomes of conventional metallic versus modern non-metallic cerclage systems for PFFs and proximal femoral osteotomy. Methods The PubMed, MEDLINE, and Google Scholar databases were searched for clinical studies reporting PFFs or extended trochanteric osteotomy (ETO) in THA patients and cerclage fixation techniques. Results Eight studies with 1362 patients (1366 hips) were included. The mean age ranged from 48.2 to 81.7 years, and the study population was 79.4 % female. The infection rate at the site of the PFF or ETO was 0.22 % (3 of 1366 hips), all occurring in patients with non-metallic cerclage fixation. Sixteen of 18 (88.9 %) cases of stem subsidence occurred following metallic cerclage fixation. Significant stem subsidence was substantially higher in hips with metallic device fixation compared to those with non-metallic fixation, at rates of 5.1 % and 0.19 %, respectively. Hips with non-metallic fixation had a clinical or radiologic healing rate of 93.9 %. Loss of fixation was only seen in hips with metallic fixation, at a rate of 0.6 %. Postoperative outcome scores were comparable across both groups. Conclusion The findings of this systematic review suggest that available non-metallic cerclage fixation methods demonstrate similar clinical success as conventional metallic fixation methods when utilized in hip arthroplasty. The current use of novel materials appears to be safe and reliable for these surgeries and can be considered a dependable option for surgeons. Level of evidence Level IV, systematic review of level III and IV studies.
Collapse
Affiliation(s)
- Ali Parsa
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
| | - Zayd Chishti
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
| | - Sheema K. Saeed
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
| | | | - Benjamin G. Domb
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
- American Hip Institute, Chicago, IL, 60018, USA
| | - Mark F. Schinsky
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
- American Hip Institute, Chicago, IL, 60018, USA
| |
Collapse
|
7
|
Hu Y, Xu Z, Qiao H, Kong K, Li H, Zhang J. Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study. BMC Musculoskelet Disord 2023; 24:970. [PMID: 38102625 PMCID: PMC10722768 DOI: 10.1186/s12891-023-07080-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Accepted: 11/29/2023] [Indexed: 12/17/2023] Open
Abstract
BACKGROUND Nickel-Titanium shape-memory sawtooth-arm embracing clamps (SSECs) have been used in revision total hip arthroplasties (rTHAs) to protect stem stability. This study was to introduce this technique and report its mid to long-term clinical and radiographic outcomes. METHODS We retrospectively reviewed all patients implanted with SSECs in our department from January 2008 to December 2015. 41 patients (41 hips) were finally included. Radiographs and Harris hip scores (HHS) were collected. Radiographs were blindly analyzed for evidence of loosening, subsidence and stress shielding. HHS were compared to previous records by student's t tests. The average follow-up period was 9.3 years. RESULTS All stems were stably fixed with no signs of loosening. The mean stem subsidence was 0.9 mm (range, 0 to 3 mm). Only one patient (2.4%) demonstrated the fourth degree of stress shielding, with the others none or minor bone resorption. The mean HHS at the final follow-up was 84.2 (range, 81 to 91), which was improved from 17.4 (range, 0 to 37) before surgery. No implant failures or re-revisions occurred. Dislocation occurred in 1 case during the follow-up period. CONCLUSIONS The SSEC protected stem fixation and achieved favorable clinical and radiographic outcomes in this 9-year follow-up study. It offered an additional extramedullary fixation option for surgeons to choose from in treating complex femoral revision arthroplasties.
Collapse
Affiliation(s)
- Yi Hu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China
| | - Zhengquan Xu
- Department of Orthopaedic Surgery, Suzhou Hospital, Nanjing Medical University, 16# Baita West Road, Suzhou, Jiangsu, 215000, P. R. China
| | - Hua Qiao
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China
| | - Keyu Kong
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China
| | - Huiwu Li
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China.
| | - Jingwei Zhang
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China.
| |
Collapse
|
8
|
Jeong SJ, Park CW, Cho K, Jeong J, Lim SJ, Park YS. Rectangular Taper Stem Designs Are Associated With a Higher Risk for Periprosthstic Femoral Fractures After Cementless Total Hip Arthroplasty. J Arthroplasty 2023; 38:2379-2385. [PMID: 37271230 DOI: 10.1016/j.arth.2023.05.052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 05/16/2023] [Accepted: 05/20/2023] [Indexed: 06/06/2023] Open
Abstract
BACKGROUND Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF. METHODS A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper hydroxyapatite-coated stems (type B2). Multivariate regression analyses were performed to identify independent factors related to PFF. The mean follow-up duration was 61 months (range, 12 to 139). Overall, 45 (1.4%) postoperative PFFs occurred. RESULTS The incidence of PFF was significantly higher in type B1 stems than in type A and type B2 stems (1.8 versus 0.7 versus 0.7%; P = .022). Additionally, more surgical treatments (1.7 versus 0.5 versus 0.7%; P = .013) and femoral revisions (1.2 versus 0.2 versus 0%; P = .004) were required for PFF in type B1 stems. After controlling for confounding variables, older age, diagnosis of hip fracture, and use of type B1 stems were significant factors associated with PFF. CONCLUSION Type B1 rectangular taper stems were found to have higher risks for postoperative PFF and PFF requiring surgical management than type A and type B2 stems in THA. Femoral stem geometry should be considered when planning for cementless THA in elderly patients who have compromised bone quality.
Collapse
Affiliation(s)
- Sang-Jin Jeong
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Chan-Woo Park
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Kyungjun Cho
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jusam Jeong
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Seung-Jae Lim
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Youn-Soo Park
- Department of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
9
|
Lowe J, Winkel T. Argument for Noncemented Hemiarthroplasty in Geriatric Hip Fractures. J Orthop Trauma 2023; 37:e384-e386. [PMID: 37587569 DOI: 10.1097/bot.0000000000002648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/18/2023]
Affiliation(s)
- Jason Lowe
- University of Arizona, College of Medicine, Tucson, AZ
| | | |
Collapse
|
10
|
Calkins TE, Goetz DD, Zalewski JT, Jones CA, Gaumer PR, Ford MC, Toy PC, Crockarell JR, Harkess JW, Mihalko WM, Guyton JL. Hip Arthroplasty Femoral Stem Designs and Their Association With Early Postoperative Periprosthetic Femoral Fractures. J Arthroplasty 2022; 38:849-854. [PMID: 36535442 DOI: 10.1016/j.arth.2022.12.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 12/06/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA), especially those in contact with the diaphyseal stem, carry high morbidity. This study evaluated how stem design influences the risk of early Vancouver B PFF or other PFF requiring operative intervention after THA. METHODS A multicenter, retrospective study of 3,433 primary cementless THAs performed from 2014 to 2021 included 2,302 single-taper (micro M/L [n = 1,169]; M/L [n = 1,133]) and 1,131 double-taper (fit-and-fill [n = 420]; compaction-collared [n = 711]) stems. Mean follow-up was 2.2 years (range, 0.3 to 6.5 years). Primary outcomes were Vancouver B and surgically treated postoperative PFFs among differing femoral stems. Secondary outcomes included rates of intraoperative and postoperative Vancouver A and C PFFs. RESULTS Forty five postoperative PFFs (1.3%) occurred within 8.8 weeks (median), 25 of which were Vancouver B (0.7%) and 20 total PFFs that required operative intervention (0.6%). Compaction-collared stems had a decreased risk of Vancouver B (hazard ratio 0.18, 95% confidence interval: 0.03-0.97 P = .044) and any surgically treated PFF (hazard ratio 0.10, 95% confidence interval: 0.01-0.95; P = .037). Intraoperative PFFs were most common with fit-and-fill stems (3.6%, P < .001) and Vancouver A with compaction-collared stems (1.8%, P < .001). The cohort with PFF had a higher Charlson comorbidity index (P = .004), more women (P = .001), more Dorr A or C femora (P = .013), and more posterior or lateral surgical approaches compared to those without PFF (P ≤ .001). CONCLUSION After controlling for confounding variables, compaction-collared stems had a significantly lower risk of postoperative Vancouver B and PFF requiring operative treatment than single-taper and double-taper stems.
Collapse
Affiliation(s)
- Tyler E Calkins
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | | | - Jacob T Zalewski
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Caleb A Jones
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | | | - Marcus C Ford
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Patrick C Toy
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - John R Crockarell
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - James W Harkess
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - William M Mihalko
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - James L Guyton
- Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| |
Collapse
|
11
|
Long-Term Outcomes of Revision Total Hip Arthroplasty Using a Tapered and Fluted Modular Stem: A Mean Follow-Up of 16 Years. J Arthroplasty 2022; 37:2420-2426. [PMID: 35753649 DOI: 10.1016/j.arth.2022.06.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 06/17/2022] [Accepted: 06/17/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Tapered modular stems are increasingly used in revision total hip arthroplasty (THA) with deficient femoral bone stock. This study aimed to report the long-term outcomes of revision THA using a tapered and fluted modular stem. METHODS Between December 1998 and February 2006, 113 revision THAs (110 patients) were performed with a tapered and fluted modular stem at a single institution. Hip radiographs were used to identify stem subsidence, stability, and femoral radiolucency. Final outcomes were assessed in 72 hips (70 patients), with a minimum follow-up of 10 years. RESULTS The mean follow-up duration was 16 years (range, 10-23). At the final evaluation, the Harris Hip Score improved from a mean of 41 points (range, 10-72) preoperatively to 83 points (range, 56-100) (P < .001). Six femoral re-revisions were performed for the following reasons: 1 aseptic loosening, 2 stem fractures, and 3 infections. One stem fracture occurred at the modular junction after 14 years, and the other at a more distal location after 15 years. Stem subsidence was >5 mm in 6 hips (9.1%), but secondary stability was achieved in all stems. Osseointegration was observed in 63 (95.5%) hips. Stem survivorship was 91.1% with an end point of any re-revision and 94.6% for aseptic re-revision. CONCLUSION A tapered and fluted modular stem demonstrated excellent implant survivorship with reliable bony fixation at a mean follow-up of 16 years. This type of stem can be a durable option for revision THA in patients who have femoral defects.
Collapse
|
12
|
Femur Strength is Similar Before and After Iatrogenic Fracture During Total Hip Arthroplasty: A Biomechanical Analysis. Arthroplast Today 2022; 15:47-54. [PMID: 35399985 PMCID: PMC8987314 DOI: 10.1016/j.artd.2022.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 01/16/2022] [Accepted: 02/12/2022] [Indexed: 11/20/2022] Open
|
13
|
Fixation of intraoperative proximal femoral fractures during THA using two versus three cerclage wires - a biomechanical study. BMC Musculoskelet Disord 2022; 23:40. [PMID: 34996409 PMCID: PMC8742345 DOI: 10.1186/s12891-021-04956-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 12/12/2021] [Indexed: 11/10/2022] Open
Abstract
Background Intraoperative proximal femoral fractures (IPFF) are relevant complications during total hip arthroplasty. Fixation using cerclage wires (CW) represents a minimally-invasive technique to address these fractures through the same surgical approach. The goal of treatment is to mobilise the patient as early as possible, which requires high primary stability. This study aimed to compare different cerclage wire configurations fixing IPFF with regard to biomechanical primary stability. Methods Standardised IPFF (type II, Modified Mallory Classification) were created in human fresh frozen femora and were fixed either by two or three CW (1.6 mm, stainless steel). All cadaveric specimens (n = 42) were randomised to different groups (quasi-static, dynamic) or subgroups (2 CW, 3 CW) stratified by bone mineral density determined by Dual Energy X-ray Absorptiometry. Using a biomechanical testing setup, quasi-static and dynamic cyclic failure tests were carried out. Cyclic loading started from 200 N to 500 N at 1 Hz with increasing peak load by 250 N every 100 cycles until failure occurred or maximum load (5250 N) reached. The change of fracture gap size was optically captured. Results No significant differences in failure load after quasi-static (p = 0.701) or dynamic cyclic loading (p = 0.132) were found between the experimental groups. In the quasi-static load testing, all constructs resisted 250% of the body weight (BW) of their corresponding body donor. In the dynamic cyclic load testing, all but one construct (treated by 3 CW) resisted 250% BW. Conclusions Based on this in vitro data, both two and three CW provided sufficient primary stability according to the predefined minimum failure load (250% BW) to resist. The authors recommend the treatment using two CW because it reduces the risk of vascular injury and shortens procedure time. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-04956-5.
Collapse
|
14
|
Israel SK, Liska WD. Outcome of canine cementless collared stem total hip replacement with proximal femoral periprosthetic cerclage application: 184 consecutive cases. Vet Surg 2021; 51:270-278. [PMID: 34655241 DOI: 10.1111/vsu.13740] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 08/18/2021] [Accepted: 09/24/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To report outcomes of cementless collared stem total hip replacement (THR) with proximal femoral periprosthetic cerclage application in dogs. STUDY DESIGN Retrospective case series. ANIMALS Client-owned dogs (n = 150) with THR (n = 184). METHODS Serial postoperative radiographs and medical records of dogs that underwent consecutive index cementless THR, with a single full cerclage wire placed distal to the femoral neck osteotomy line and proximal to the lesser trochanter, were reviewed for intraoperative and postoperative complications. RESULTS No proximal femoral fractures occurred. No complications associated with the use of the cerclage wire were encountered. A fissure (n = 1) or fractures (n = 2) occurred near the tip of the femoral stem in three cases postoperatively. All three cases required plate and screw fixation. All dogs returned to subjectively normal function at home and all owners were satisfied with the outcome. CONCLUSION A single full cerclage wire may minimize the risk of a proximal femur fracture following cementless collared stem total hip replacement in dogs. No complications were encountered with the cerclage wire. CLINICAL SIGNIFICANCE Application of a cerclage wire is a simple and economically feasible procedure that requires minimal additional instrumentation, takes little time, and may decrease the risk of proximal femur fractures after cementless press-fit THR.
Collapse
|
15
|
Mei J, Pang L, Jiang Z. Strategies for managing the destruction of calcar femorale. BMC Musculoskelet Disord 2021; 22:460. [PMID: 34011332 PMCID: PMC8136139 DOI: 10.1186/s12891-021-04324-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Accepted: 05/05/2021] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND The calcar femorale was identified long ago. However, our current understanding of the calcar is insufficient, and its related concepts are sometimes confused. The calcar femoral is an important anatomical structure of the proximal femur, and its function can be overlooked. In trauma, tumors, or other diseases, the calcar femorale can be destroyed or changed pathologically. As a result, the mechanical structure of the proximal femur becomes destroyed, causing pathological fractures. How to address the destruction of the calcar femorale or the damage to the calcar femorale is discussed in this article. MAIN TEXT Destruction of the calcar femorale is accompanied by many conditions, including trauma, tumors, and other diseases. The types of hip fractures caused by trauma include femoral neck fractures and intertrochanteric fractures. Dynamic hip screws, proximal femoral nail anti-rotation, and multiple parallel cannulate pins can be used in different conditions. When metastatic and primary bone tumors involve the calcar femorale, endoprostheses are widely used. Other diseases, such as fibrous dysplasia and aneurysmal bone cyst are treated differently. CONCLUSIONS The calcar femorale can redistribute stresses and the destruction of the calcar femorale can lead to an increase in posterior medial stress. Many factors need to be considered when deciding whether to reconstruct the calcar femorale. Effective treatment strategies for managing the destruction of calcar femorale will need first establishing the precise mechanism of the destruction of the calcar and then designing therapies towards these mechanisms. Further investigation to the calcar needs to be carried out.
Collapse
Affiliation(s)
- Jin Mei
- Hospital of Chengdu University of Traditional Chinese Medicine, Chengdu, 610072 Sichuan Province China
| | - Lili Pang
- Hospital of Chengdu University of Traditional Chinese Medicine, Chengdu, 610072 Sichuan Province China
| | - Zhongchao Jiang
- Hospital of Chengdu University of Traditional Chinese Medicine, Chengdu, 610072 Sichuan Province China
| |
Collapse
|