1
|
Axenhus M, Salemyr M, Mukka S, Magnéli M, Sköldenberg O. Long-term follow-up of bone density changes in total hip arthroplasty: comparative analysis from a randomized controlled trial of a porous titanium construct shell vs. a porous coated shell. INTERNATIONAL ORTHOPAEDICS 2024; 48:2835-2842. [PMID: 39243289 PMCID: PMC11490515 DOI: 10.1007/s00264-024-06289-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Accepted: 08/20/2024] [Indexed: 09/09/2024]
Abstract
PURPOSE Periacetabular bone loss poses a considerable challenge in the longevity and stability of acetabular implants used in total hip arthroplasty (THA). Innovations in implant design, specifically the introduction of three-dimensional (3D) porous titanium constructs, might reduce bone resorption. The purpose of this study was to build upon our previous randomized controlled trial, which found no change in periacetabular bone loss between a 3D porous none-hydroxyapatite coated titanium cup and a standard porous hydroxyapatite coated cup over a two year follow-up period by extending the follow-up duration to ten years post-surgery. METHODS This was a single-centre, long-term follow-up study conducted over a ten year period in patients who had previously participated in a randomized controlled trial comparing a 3D porous titanium construct shell (PTC group) with a standard porous hydroxyapatite coated titanium shell (PC-group). The primary outcome measured was the change in bone mineral density (BMD) within four specific periacetabular zones, alongside overall bone loss, which was assessed through BMD in the lumbar spine at two, six and ten years postoperatively. Secondary outcomes included clinical outcome measures. RESULTS In total, 18 in the PTC and 20 in the PC group were analysed for the primary endpoint up to ten years. The mean bone mineral density in zones 1-4 was 3.7% higher in the PTC group than in the PC group at six years postoperatively and 12.0% higher at ten years. Clinical outcomes, and the frequency of adverse events did not differ between the groups. CONCLUSIONS The PTC group displayed superior long-term bone preservation compared to the PC group while maintaining similar clinical outcomes up to ten years postoperatively. Although with a small sample size, our findings suggest that porous titanium cups have the potential to minimize BMD loss around the cup which could contribute to improving THA outcomes and implant durability.
Collapse
Affiliation(s)
- Michael Axenhus
- Division of Orthopaedics, Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Entrévägen 2, 182 88, Danderyd, Stockholm, Sweden.
| | - Mats Salemyr
- Division of Orthopaedics, Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Entrévägen 2, 182 88, Danderyd, Stockholm, Sweden
| | - Sebastian Mukka
- Department of Diagnostics and Intervention (Orthopaedics), Umeå University, Umeå, Sweden
| | - Martin Magnéli
- Division of Orthopaedics, Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Entrévägen 2, 182 88, Danderyd, Stockholm, Sweden
| | - Olof Sköldenberg
- Division of Orthopaedics, Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Entrévägen 2, 182 88, Danderyd, Stockholm, Sweden
| |
Collapse
|
2
|
Afghanyar Y, Afghanyar B, Loweg L, Drees P, Gercek E, Dargel J, Rehbein P, Kutzner KP. Ten-year clinical and radiological outcomes with a vitamin E-infused highly cross-linked polyethylene acetabular cup. Bone Jt Open 2024; 5:825-831. [PMID: 39357881 PMCID: PMC11446611 DOI: 10.1302/2633-1462.510.bjo-2023-0179.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/04/2024] Open
Abstract
Aims Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and radiological outcomes at a minimum of ten years' follow-up. Methods This prospective observational study investigated 101 cases of primary THA over a mean duration of 129 months (120 to 149). At last follow-up, 57 cases with complete clinical and radiological outcomes were evaluated. In all cases, the acetabular component comprised an uncemented titanium particle-coated VEPE monoblock cup. Patients were assessed clinically and radiologically using the Harris Hip Score, visual analogue scale (pain and satisfaction), and an anteroposterior radiograph. Cup migration and polyethylene wear were measured using Einzel-Bild-Röntgen-Analyze software. All complications and associated treatments were documented until final follow-up. Results Clinical assessment showed persistent major improvement in all scores. On radiological assessment, only one case showed a lucent line (without symptoms). At last follow-up, wear and migration were below the critical thresholds. No cup-related revisions were needed, indicating an outstanding survival rate of 100%. Conclusion Isoelastic VEPE cups offer high success rates and may prevent osteolysis, aseptic loosening, and the need for revision surgeries in the long term. However, longer follow-up is needed to validate our findings and confirm the advantages offered by this cup.
Collapse
Affiliation(s)
- Yama Afghanyar
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany
- Department of Orthopaedics, St. Josefs-Hospital Wiesbaden, Wiesbaden, Germany
| | - Bedjan Afghanyar
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany
| | - Lennard Loweg
- Department of Orthopaedics, St. Josefs-Hospital Wiesbaden, Wiesbaden, Germany
| | - Philipp Drees
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany
| | - Erol Gercek
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany
| | - Jens Dargel
- Department of Orthopaedics, St. Josefs-Hospital Wiesbaden, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedics, St. Josefs-Hospital Wiesbaden, Wiesbaden, Germany
| | - Karl P Kutzner
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Mainz, Germany
- ENDOPROTHETICUM, Mainz, Germany
| |
Collapse
|
3
|
Portet A, Besnard M, Ratsimbazafy C, Berhouet J, Samargandi R, Le Nail LR. The RM Press fit cup™: an investigation in 182 hips at ten-year follow-up. Orthop Traumatol Surg Res 2024:103988. [PMID: 39245266 DOI: 10.1016/j.otsr.2024.103988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 08/04/2024] [Accepted: 09/05/2024] [Indexed: 09/10/2024]
Abstract
INTRODUCTION For over 10 years, the RM Pressfit cup™ has been used in our department. This is a one-piece, elastic, cementless implant designed with standard polyethylene (PE), covered with a thin coating of titanium particles. To date, there is no French study evaluating this cup after more than 10 years. Therefore, we conducted a retrospective study in order to: (1) evaluate the survival of the implant with a minimum follow-up of 10 years, (2) evaluate the functional scores at the last follow-up, (3) measure the wear of the PE, (4) identify radiological loosening, (5) search for risk factors for cup removal, (6) identify complications that required management in the operating theatre. HYPOTHESIS The working hypothesis was that the survival of this implant was greater than 95% at 10 years' follow-up, in accordance with the criteria of the National Institute for Health and Care Excellence (NICE). MATERIALS AND METHODS This was a retrospective monocentric study, including adult patients who underwent total hip arthroplasty (THA) with an RM Pressfit cup™ (28 mm friction size) for coxarthrosis (primary or secondary) or femoral head osteonecrosis. Exclusion criteria were a follow-up period of less than 10 years, the placement of an RM Pressfit cup™ as a secondary intention for a THA (n = 5) or following a trochanteric fracture (n = 1). In total, 163 patients (182 hips) with a median age (Q1-Q3) of 63 (56-68) years, and a sex ratio (M/F) of 1.7 were included. Functional scores were evaluated using the Harris and Oxford scores. Radiographs were analyzed in the immediate postoperative period and at the last follow-up. RESULTS The median follow-up was 10.5 (10-11.5) years. Of the 182 included hips, 7 cups were removed, corresponding to a 10-year survival rate of 96.1% (95% CI [93.3; 96.9]). The median Harris and Oxford scores at 10.5 years were 95 (90-98) and 19 (17-23) points, respectively. The median PE wear rate was 0.058 (0.039-0.087) mm/year. Univariate analysis showed that male gender was associated with PE wear (OR = 3.6; 95% CI [1.3; 12.9] [p = 0.012]). Ten cups (6%) showed radiological instability with migration greater than 3 mm and/or variation in inclination greater than 8 °, and only 9 hips (6%) showed bone resorption. No preoperative or perioperative factors analyzed were associated with cup removal. Dislocation accounted for 71% (n = 5) of the causes of cup removal. Additionally, 6 hips experienced at least one dislocation episode requiring reduction by external maneuvers in the operating room, bringing the overall dislocation rate in the series to 6% (n = 11). Increased cup inclination was the only risk factor for prosthetic dislocation (OR = 1.2; 95% CI [1.09; 1.4] [p = 0.0003]). Overall complications requiring surgical intervention included 15 (8.3%) implanted cups (7 removed cups, 6 dislocation episodes requiring reduction by external maneuvers in the operating room, and 2 hips reoperated for washing and changing of mobile components due to early infection). CONCLUSION The RM Pressfit cup™ gives good long-term clinical and radiological results with an overall survival of 96.1% and a low complication rate over 10 years. Over the last 2 years the RM Vitamys™ cup has been introduced allowing the use of 32 mm femoral head diameter for size 48 cups, to reduce the risk of dislocation. LEVEL OF EVIDENCE IV; retrospective cohort.
Collapse
Affiliation(s)
- Adrien Portet
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France.
| | - Marion Besnard
- Centre Hospitalier Intercommunal Amboise-Château-Renault, Hôpital Robert-Debré, rue des Ursulines, BP 329, 37403 Amboise Cedex, France
| | - Carole Ratsimbazafy
- Hôpital Saint-Antoine, Pharmacie, GHU AP-HP Sorbonne Université 184 rue du Faubourg-Saint-Antoine, 75012 Paris, France
| | - Julien Berhouet
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France
| | - Ramy Samargandi
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France; Department of Orthopedic Surgery, Faculty of Medicine, University of Jeddah, Jeddah, Saudi Arabia
| | - Louis-Romée Le Nail
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France
| |
Collapse
|
4
|
Mittelstaedt H, Anderl C, Ortmaier R, Johl C, Krüger T, Wallroth K, Weigert U, Schagemann JC. Subsidence analysis of a cementless short stem THA using EBRA-FCA - A seven-year prospective multicentre study. J Orthop 2023; 43:93-100. [PMID: 37575949 PMCID: PMC10415660 DOI: 10.1016/j.jor.2023.06.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 06/26/2023] [Indexed: 08/15/2023] Open
Abstract
Background Metaphyseal fixation of short stem THA allows for minimally invasive surgery, less bone removal, improved bone load transfer and reduced stress shielding. Short stems facilitate the anatomic restoration i.a. of leg length, femoroacetabular offset, and center of rotation. However, metaphyseal fixation might cause impaired primary and/or secondary stability resulting in an inherent tendency for early axial migration and aseptic loosening eventually. The objective of this study was to investigate the long-term outcome and migration pattern of a calcar-guided short stem. Methods In a prospective multicenter study, 213 patients (224 THAs) were enrolled. Patients were followed for up to 84 months postoperatively. Clinical outcome was assessed using the Harris Hip Score and the VAS for pain and satisfaction. Standardized and calibrated radiographs were screened i.a. for stress shielding and loosening. Einzel-Bild-Roentgen-Analyse - femoral component analysis (EBRA-FCA) was used to detect longitudinal subsidence. Results At 7 year follow-up, n = 139/224 cases were available for analysis. All clinical parameters improved significantly (p < 0.001) and improvement persisted. There were no radiographic changes indicating stress shielding. EBRA-FCA revealed a mean subsidence of -1.44 mm followed by a stabilization. Weight >80 kg (p = 0.115), BMI <30 kg/m2 (p = 0.282), male gender (p = 0.246), and age <65 years (p = 0.304) seemed to be associated with a higher risk for migration. The cumulative revision rate was 2.23%. Revisions due to stem migration (0.89%) occurred early (mean time between index surgery and revision: 3.3 months). Conclusions If at all, there appears to be a pronounced initial subsidence, which stabilizes thereafter. Stem migration was rarely a compelling reason for failure or revision. Demographics do not seem to have a significant effect on migration pattern. The absence of radioluce lines, resorption or hypertrophy of the proximal femora support the hypothesis of a reduced stress shielding for metaphyseal anchoring short stems.
Collapse
Affiliation(s)
- Hagen Mittelstaedt
- UKSH Campus Lübeck, Klinik für Orthopädie und Unfallchirurgie Sektion Orthopädie, Ratzeburger Allee, Lübeck, Germany
| | - Conrad Anderl
- Ordensklinikum Linz, Krankenhaus der Barmherzigen Schwestern Linz GmbH, Seilerstätte, Linz, Austria
| | - Reinhold Ortmaier
- Ordensklinikum Linz, Krankenhaus der Barmherzigen Schwestern Linz GmbH, Seilerstätte, Linz, Austria
| | - Carsten Johl
- Klinikum Dahme-Spreewald GmbH, Lübben (Spreewald), Germany
| | - Thomas Krüger
- Helios Klinik Köthen, Hallesche Straße, Köthen (Anhalt), Germany
| | - Karsten Wallroth
- Kreiskrankenhaus Stollberg GmbH, Jahnsdorfer Straße Stollberg, Stollberg, Germany
| | - Ulrich Weigert
- Praxis für Orthopädie und Unfallchirurgie, Friedrichstraße, Erkner, Germany
| | - Jan C. Schagemann
- UKSH Campus Lübeck, Klinik für Orthopädie und Unfallchirurgie Sektion Orthopädie, Ratzeburger Allee, Lübeck, Germany
- Christophorus Kliniken Coesfeld, Südring 41, 48653, Coesfeld, Germany
| |
Collapse
|
5
|
Christodoulou N, Volonakis E, Voutsas K, Raptis K, Koutserimpas C. Early Clinical and Radiographic Outcomes of Total Hip Arthroplasty with DELTA ST-C Cup and MINIMA S Stem. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:medicina59030607. [PMID: 36984608 PMCID: PMC10058963 DOI: 10.3390/medicina59030607] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/08/2023] [Accepted: 03/17/2023] [Indexed: 03/30/2023]
Abstract
Background and Objectives: The uncemented threaded DELTA ST-C cup was introduced in last few years. It has a hemispheric shell, consisting of Ti6Al4V titanium alloy. The MINIMA S stem was developed according to the principles of proximal-loading and extended metaphyseal geometry applied to a short stem. The purpose of the study was to assess the clinical and radiographic outcomes and the short- and mid-term survivorship of the DELTA ST-C cup and MINIMA S stem in patients undergoing total hip arthroplasty (THA). The present is the first study to report outcomes and implant survivorship of the DELTA ST-C cup coupled with the MINIMA S femoral stem. Materials and Methods: The present study is a retrospective observational cohort study of a prospectively maintained database, evaluating clinical outcomes and implant survivorship in 95 patients undergoing THA with the MINIMA stem coupled with the DELTA ST-C cup with at least a 3-year follow-up. The clinical evaluation was assessed with a change in the Harris hip score (HHS), while the radiographic evaluation included anteroposterior views of the pelvis and lateral views of the affected hip. Results: The enrolled population's mean age was 69.3 years and most patients were female (64%). The MINIMA S standard stem was implanted in 68 patients (72%), the lateralized stem was implanted in 27 (28%), and the mean acetabular inclination was 48.2°. The HHS improved significantly from the preoperative value (median 46, IQR: 38-55), already at 1 month after surgery (median 76, IQR: 66-77), reaching excellent results at 1 year and 3 years postoperatively (median 96, IQR: 91-100). X-rays demonstrated good implant stability and biomechanics parameter restorations revealed no sign of subsidence, and the presence of radiolucent lines greater than 2 mm in the short stem area in five cases and in the acetabulum in one were not clinically significant. No revisions have been performed so far. Conclusions: The MINIMA S stem coupled with the DELTA ST-C cup demonstrated very good clinical and radiological results with a significant increase of the Harris hip score at short- and mid-term follow-up. This is the first study evaluating the DELTA ST-C cup, showing promising outcomes during the study's follow-up. The MINIMA S stem has been evaluated in a very few studies. However, the combination with this particular cup had not yet been studied. The design of the stem and the cup ensures primary stability and excellent early term outcomes, moreover the study demonstrates extraordinary implant survivorship, equal to 100%.
Collapse
Affiliation(s)
| | - Emmanouil Volonakis
- Department of Orthopedics, Athens Medical Group, Psychicko, 11525 Athens, Greece
| | - Karatzas Voutsas
- Department of Orthopedics, Athens Medical Group, Psychicko, 11525 Athens, Greece
| | - Konstantinos Raptis
- Department of Orthopedics and Traumatology, "251" Hellenic Air Force General Hospital of Athens, Kanellopoulou Av, 11525 Athens, Greece
| | - Christos Koutserimpas
- Department of Orthopedics and Traumatology, "251" Hellenic Air Force General Hospital of Athens, Kanellopoulou Av, 11525 Athens, Greece
| |
Collapse
|
6
|
Femoral Head Autograft to Manage Acetabular Bone Loss Defects in THA for Crowe III Hips by DAA: Retrospective Study and Surgical Technique. J Clin Med 2023; 12:jcm12030751. [PMID: 36769400 PMCID: PMC9918157 DOI: 10.3390/jcm12030751] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/09/2023] [Accepted: 01/16/2023] [Indexed: 01/20/2023] Open
Abstract
Introduction: The pathologic anatomy of Crowe III is characterized by the erosion of the superior rim of acetabulum, with a typical bone defect in its supero-lateral portion. The performance of a total hip arthroplasty requires the management of the acetabular bone defect, and femoral head autograft can be a valid option to optimize implant coverage. Material and Methods: In all, eight Crowe III patients (nine hips), seven of which having unilateral hip affected, and one with bilateral involvement by secondary osteoarthritis in DDH; maximum limb length discrepancy (LLD) of 3.5 cm in unilateral patients. All were operated on by direct anterior approach. Patients were evaluated in terms of clinical, surgical, and radiological (center-edge, horizontal coverage, cup inclination) parameters. Results: Cup placement was implanted with a mean of 39.5 ± 7.5°. Stem alignment showed average 1.5 ± 2.3° in valgus. LLD showed an overall average preoperative of -29.5 ± 10.5 mm at the affected side, with a significant improvement to -2.5 ± 6.4 mm (p = 0.023). The mean initial coverage evaluated like a percentage of the horizontal bone host was 52.1 ± 7.1%, while the mean final coverage at the last post-operative X-ray from femoral autograft bone was 97.0 ± 4.5% with an average improvement of 44.5%. Average CE improved from -9.5 ± 5.2° (CE I) to the immediate post-operative (CE II) of 40.6 ± 8.2°. At the final follow up, CE III showed a mean of 38.6 ± 6.2°, with an average decrease of 2.0°. Discussion: Acetabular bone defect in Crowe III DDH patients undergoing THA by DAA, can be efficiently managed by massive autograft femoral head, which allowed an adequate and long-lasting coverage of the implant, with cup positioning at the native acetabulum.
Collapse
|
7
|
Saracco M, Fidanza A, Necozione S, Maccauro G, Logroscino G. Could Short Stems THA Be a Good Bone-Saving Option Even in Obese Patients? J Clin Med 2022; 11:jcm11237114. [PMID: 36498685 PMCID: PMC9739638 DOI: 10.3390/jcm11237114] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 11/23/2022] [Accepted: 11/26/2022] [Indexed: 12/03/2022] Open
Abstract
Short femoral stems, with preservation of the femoral bone stock, are commonly used in recent years for hip replacement in younger and more active patients. Obesity is increasingly spreading even in the younger population. The aim of this case-series study is to evaluate short stems compared to traditional hip prostheses in the obese population. A total of 77 consecutive patients with a BMI greater than or equal to 30 Kg/m2 were enrolled in this prospective study and were divided into two groups: 49 patients have been implanted with short stems while 28 patients were implanted with traditional stems. All the patients were treated for primary osteoarthritis or avascular necrosis and all the stems were implanted by the same surgeon using a posterior approach. Clinical (Harris Hip Score—HHS, Western Ontario and McMaster Universities Osteoarthritis Index—WOMAC, visual analogue scale—VAS, 12-item Short Form Health Survey—SF-12) and radiographic outcomes were recorded. Radiological evaluations were carried out by three different blinded surgeons. A statistical analysis was performed (chi-square, t-test, Wilcoxon Rank Sum Test, 2-factor ANOVA). At a mean follow-up of 42.6 months both groups showed a marked improvement in pain and in the clinical scores between pre- and post-surgical procedures (p < 0.05) with no significant differences between the two groups at last follow-up (p > 0.05). The radiological evaluations, with high concordance correlation between the three blinded surgeons (ICC consistently >0.80), showed good positioning and osseointegration in all cases, with no significant differences in the restoration of the joint geometry and complications. No revisions were recorded during the follow-up period. In conclusion, short stems appear to be a good option for bone preservation even in obese patients, showing comparable results to traditional implants.
Collapse
Affiliation(s)
- Michela Saracco
- “A. Gemelli” IRCCS University Hospital Foundation, Catholic University of Sacred Heart, 00168 Rome, Italy
- Department of Orthopaedics, ASL Napoli 2 Nord, 80027 Naples, Italy
| | - Andrea Fidanza
- Department Life, Health and Environmental Sciences—Mininvasive Orthopaedic Surgery, University of L’Aquila, 67100 L’Aquila, Italy
- Correspondence:
| | - Stefano Necozione
- Department Life, Health and Environmental Sciences—Unit of Epidemiolody, University of L’Aquila, 67100 L’Aquila, Italy
| | - Giulio Maccauro
- “A. Gemelli” IRCCS University Hospital Foundation, Catholic University of Sacred Heart, 00168 Rome, Italy
| | - Giandomenico Logroscino
- Department Life, Health and Environmental Sciences—Mininvasive Orthopaedic Surgery, University of L’Aquila, 67100 L’Aquila, Italy
| |
Collapse
|