1
|
Broekhuis D, Meurs WMH, Kaptein BL, Karunaratne S, Carey Smith RL, Sommerville S, Boyle R, Nelissen RGHH. High accuracy of positioning custom triflange acetabular components in tumour and total hip arthroplasty revision surgery. Bone Jt Open 2024; 5:260-268. [PMID: 38555947 PMCID: PMC10981996 DOI: 10.1302/2633-1462.54.bjo-2023-0185.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/02/2024] Open
Abstract
Aims Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions. Methods A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed. Results CTAC positioning was generally accurate, with minor deviations in cup inclination (mean 2.7°; SD 2.84°), anteversion (mean 3.6°; SD 5.04°), and rotation (mean 2.1°; SD 2.47°). Deviation of the hip centre of rotation (COR) showed a mean vector length of 5.9 mm (SD 7.24). Flange positions showed small deviations, with the ischial flange exhibiting the largest deviation (mean vector length of 7.0 mm; SD 8.65). Overall, 83% of the implants were accurately positioned, with 17% exceeding malpositioning thresholds. CTACs used in tumour resections exhibited higher positioning accuracy than rTHA cases, with significant differences in inclination (1.5° for tumour vs 3.4° for rTHA) and rotation (1.3° for tumour vs 2.4° for rTHA). The use of intraoperative navigation appeared to enhance positioning accuracy, but this did not reach statistical significance. Conclusion This study demonstrates favourable CTAC positioning accuracy, with potential for improved accuracy through intraoperative navigation. Further research is needed to understand the implications of positioning accuracy on implant performance and long-term survival.
Collapse
Affiliation(s)
- Demien Broekhuis
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | - Willemijne M. H. Meurs
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | - Bart L. Kaptein
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| | - Sascha Karunaratne
- Surgical Outcomes Research Centre (SOuRCe), Royal Prince Alfred Hospital, Sydney, Australia
| | | | - Scott Sommerville
- Department of Orthopaedic Surgery, Princess Alexandra Hospital, Brisbane, Australia
| | - Richard Boyle
- Department of Orthopaedic Surgery, Royal Prince Alfred Hospital, Sydney, Australia
| | - Rob G. H. H. Nelissen
- Department of Orthopaedic Surgery, Leiden University Medical Centre, Leiden, Netherlands
| |
Collapse
|
2
|
Callary SA, Sharma DK, D’Apollonio TM, Campbell DG. Large articulations do not increase wear rates of thin second-generation highly cross-linked polyethylene liners at ten years. Bone Jt Open 2023; 4:839-845. [PMID: 37926113 PMCID: PMC10625862 DOI: 10.1302/2633-1462.411.bjo-2023-0124.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2023] Open
Abstract
Aims Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. Methods We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point. Results The median proximal, 2D, and 3D wear rates calculated between one and ten years were all less than 0.005 mm/year, with no patient recording a proximal wear rate of more than 0.021 mm/year. Importantly, there was no increase in the wear rate between five and ten years. Conclusion The very low wear rate of X3 XLPE liners with larger articulations remains encouraging for the future clinical performance of this material.
Collapse
Affiliation(s)
- Stuart A. Callary
- Centre for Orthopaedic and Trauma Research, The University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia
| | - Deepti K. Sharma
- Centre for Orthopaedic and Trauma Research, The University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
| | - Taisha M. D’Apollonio
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia
| | | |
Collapse
|
3
|
Hamilton DF, Gaston P, Macpherson GJ, Simpson P, Clement ND. Nexus Evaluation Primary Trident II UNcemented shEll (NEPTUNE). Bone Jt Open 2023; 4:782-790. [PMID: 37848192 PMCID: PMC10581835 DOI: 10.1302/2633-1462.410.bjo-2023-0052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2023] Open
Abstract
Aims The primary aim of this study is to assess the survival of the uncemented hydroxyapatite (HA) coated Trident II acetabular component as part of a hybrid total hip arthroplasty (THA) using a cemented Exeter stem. The secondary aims are to assess the complications, joint-specific function, health-related quality of life, and radiological signs of loosening of the acetabular component. Methods A single-centre, prospective cohort study of 125 implants will be undertaken. Patients undergoing hybrid THA at the study centre will be recruited. Inclusion criteria are patients suitable for the use of the uncemented acetabular component, aged 18 to 75 years, willing and able to comply with the study protocol, and provide informed consent. Exclusion criteria includes patients not meeting study inclusion criteria, inadequate bone stock to support fixation of the prosthesis, a BMI > 40 kg/m2, or THA performed for pain relief in those with severely restricted mobility. Results Implant survival, complications, functional outcomes and radiological assessment up to ten years following index THA (one, two, five, seven, and ten years) will be performed. Functional assessment will include the Oxford Hip Score, Forgotten Joint Score, 12-Item Short Form Health Survey, EuroQol five-dimension health questionnaire, and pain and patient satisfaction. Radiological assessment with assess for acetabula lucent lines, lysis, and loosening according to DeLee and Charnley zones. Conclusion This study is part of a stepwise introduction of a new device to orthopaedic practice, and careful monitoring of implants should be carried out as part of the Beyond Compliance principles. The results of this study will provide functional, radiological, and survival data to either support the ongoing use of the HA acetabulum or highlight potential limitations of this new implant before wide adoption.
Collapse
Affiliation(s)
- David F. Hamilton
- School of Health and Life Sciences, Glasgow Caledonian University, Glasgow, UK
- Department of Orthopaedics, University of Edinburgh, Edinburgh, UK
| | - Paul Gaston
- Department of Orthopaedics, University of Edinburgh, Edinburgh, UK
- Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK
| | - Gavin J. Macpherson
- Department of Orthopaedics, University of Edinburgh, Edinburgh, UK
- Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK
| | - Philip Simpson
- Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK
| | - Nick D. Clement
- Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK
| |
Collapse
|
4
|
Tsai CJ, Yang ZY, Wu TY, Tsai YT, Wang JJ, Liaw CK. The Transverse Mechanical Axis of the Pelvis for Post-Operative Evaluation of Total Hip Arthroplasty. Biomedicines 2023; 11:biomedicines11051397. [PMID: 37239066 DOI: 10.3390/biomedicines11051397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/12/2023] [Accepted: 05/01/2023] [Indexed: 05/28/2023] Open
Abstract
Currently, orthopedic surgeons mainly use the inter-teardrop line (IT-line) as the transverse mechanical axis of the pelvis (TAP) for postoperative evaluation of total hip arthroplasty (THA). However, the teardrop is often unclear in the pelvis anteroposterior (AP) radiographs, which makes postoperative evaluation of THA difficult. In this study, we attempted to identify other clear and accurate axes for postoperative evaluation of THA. We calculated the mean and standard deviation of these angles and tested the significance of these angles using t-tests. The inter-teardrops line (IT line) and the upper rim of the obturator foramen (UOF) had smaller angles with the IFH line. The bi-ischial line (BI line) was relatively inaccurate in measurements. We recommend using the IT line as the TAP when the lower boundary of the teardrops is clear and the shapes of the teardrops on both sides of the pelvis are symmetrical. When there is no deformation of the obturator foramen on pelvic AP radiographs, the UOF is also a good choice for the TAP. We do not recommend the BI line as the TAP.
Collapse
Affiliation(s)
- Cheng-Jui Tsai
- School of Medicine, College of Medicine, Taipei Medical University, Taipei City 11031, Taiwan
| | - Zong-Yan Yang
- School of Medicine, College of Medicine, Taipei Medical University, Taipei City 11031, Taiwan
| | - Tai-Yin Wu
- Department of Family Medicine, Zhongxing Branch, Taipei City Hospital, Taipei City 10341, Taiwan
- Institute of Epidemiology and Preventive Medicine, National Taiwan University, Taipei City 10055, Taiwan
- General Education Center, University of Taipei, Taipei City 10023, Taiwan
| | - Ya-Ting Tsai
- School of Medicine, China Medical University, Taichung City 404333, Taiwan
| | - Juyn-Jhe Wang
- School of Medicine, College of Medicine, Taipei Medical University, Taipei City 11031, Taiwan
| | - Chen-Kun Liaw
- Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei City 11031, Taiwan
- Department of Orthopedics, Shuang Ho Hospital, Taipei Medical University, No. 291, Zhongzheng Rd., Zhonghe Dist, New Taipei City 23561, Taiwan
- Research Center of Biomedical Device, College of Biomedical Engineering, Graduate Institute of Biomedical Optomechatronics, Taipei Medical University, Taipei City 11031, Taiwan
- TMU Biodesign Center, Taipei Medical University, Taipei 11031, Taiwan
| |
Collapse
|
5
|
Faraj S, de Windt TS, van Hooff ML, van Hellemondt GG, Spruit M. Custom-made acetabular revision arthroplasty for pelvic discontinuity: Can we handle the challenge? : a prospective cohort study. Bone Jt Open 2023; 4:53-61. [PMID: 36718581 PMCID: PMC10011926 DOI: 10.1302/2633-1462.42.bjo-2022-0159.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
AIMS The aim of this study was to assess the clinical and radiological results of patients who were revised using a custom-made triflange acetabular component (CTAC) for component loosening and pelvic discontinuity (PD) after previous total hip arthroplasty (THA). METHODS Data were extracted from a single centre prospective database of patients with PD who were treated with a CTAC. Patients were included if they had a follow-up of two years. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance and clinical relevance. RESULTS A total of 18 females with 22 CTACs who had a mean age of 73.5 years (SD 7.7) were included. A significant improvement was found in HOOS (p < 0.0001), mOHS (p < 0.0001), EQ-5D-3L utility (p = 0.003), EQ-5D-3L NRS (p = 0.013), VAS pain rest (p = 0.008), and VAS pain activity (p < 0.0001) between baseline and final follow-up. Minimal clinically important improvement in mOHS and the HOOS Physical Function Short Form (HOOS-PS) was observed in 16 patients (73%) and 14 patients (64%), respectively. Definite healing of the PD was observed in 19 hips (86%). Complications included six cases with broken screws (27%), four cases (18%) with bony fractures, and one case (4.5%) with sciatic nerve paresthesia. One patient with concurrent bilateral PD had revision surgery due to recurrent dislocations. No revision surgery was performed for screw failure or implant breakage. CONCLUSION CTAC in patients with THA acetabular loosening and PD can result in stable constructs and significant improvement in functioning and health-related quality of life at two years' follow-up. Further follow-up is necessary to determine the mid- to long-term outcome.Cite this article: Bone Jt Open 2023;4(2):53-61.
Collapse
Affiliation(s)
- Sayf Faraj
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, the Netherlands
| | - Tommy S de Windt
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, the Netherlands
| | - Miranda L van Hooff
- Department of Research, Sint Maartenskliniek, Nijmegen, the Netherlands.,Department of Orthopedic Surgery, Radboud University Medical Centre, Nijmegen, the Netherlands
| | | | - Maarten Spruit
- Department of Orthopedic Surgery, Sint Maartenskliniek, Nijmegen, the Netherlands
| |
Collapse
|
6
|
Hardwick-Morris M, Twiggs J, Miles B, Al-Dirini RMA, Taylor M, Balakumar J, Walter WL. Iliopsoas tendonitis after total hip arthroplasty : an improved detection method with applications to preoperative planning. Bone Jt Open 2023; 4:3-12. [PMID: 36598093 PMCID: PMC9887341 DOI: 10.1302/2633-1462.41.bjo-2022-0147.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
AIMS Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. METHODS This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months' follow-up. 3D models of each patient's prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model's sensitivity, specificity, and area under the curve (AUC). RESULTS Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86. CONCLUSION We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis.Cite this article: Bone Jt Open 2023;4(1):3-12.
Collapse
Affiliation(s)
- Max Hardwick-Morris
- 360 Med Care, Sydney, Australia,Flinders University, Adelaide, Australia,Correspondence should be sent to Max Hardwick-Morris. E-mail:
| | | | | | | | | | | | - William L. Walter
- Institute of Bone and Joint Research, Kolling Institute, The University of Sydney, Sydney, Australia,Department of Orthopaedics and Traumatic Surgery, Royal North Shore Hospital, Sydney, Australia
| |
Collapse
|
7
|
Fransen BL, Bengoa FJ, Neufeld ME, Sheridan GA, Garbuz DS, Howard LC. Thin highly cross-linked polyethylene liners combined with large femoral heads in primary total hip arthroplasty show excellent survival and low wear rates at a mean follow-up of 12.8 years. Bone Joint J 2023; 105-B:29-34. [PMID: 36587249 DOI: 10.1302/0301-620x.105b1.bjj-2022-0812.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
AIMS Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years' follow-up. METHODS We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. RESULTS Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm3/year (95% CI -6.5 to 28.7). CONCLUSION Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners.Cite this article: Bone Joint J 2023;105-B(1):29-34.
Collapse
Affiliation(s)
- Bas L Fransen
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Francisco J Bengoa
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Michael E Neufeld
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Gerard A Sheridan
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Donald S Garbuz
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Lisa C Howard
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| |
Collapse
|
8
|
Qu H, Mou H, Wang K, Tao H, Huang X, Yan X, Lin N, Ye Z. Risk factor investigation for hip dislocation after periacetabular tumour resection and endoprosthetic reconstruction via thin-slice CT-based 3D model. Bone Joint J 2022; 104-B:1180-1188. [PMID: 36177644 DOI: 10.1302/0301-620x.104b10.bjj-2022-0265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Dislocation of the hip remains a major complication after periacetabular tumour resection and endoprosthetic reconstruction. The position of the acetabular component is an important modifiable factor for surgeons in determining the risk of postoperative dislocation. We investigated the significance of horizontal, vertical, and sagittal displacement of the hip centre of rotation (COR) on postoperative dislocation using a CT-based 3D model, as well as other potential risk factors for dislocation. METHODS A total of 122 patients who underwent reconstruction following resection of periacetabular tumour between January 2011 and January 2020 were studied. The risk factors for dislocation were investigated with univariate and multivariate logistic regression analysis on patient-specific, resection-specific, and reconstruction-specific variables. RESULTS The dislocation rate was 13.9% (n = 17). The hip COR was found to be significantly shifted anteriorly and inferiorly in most patients in the dislocation group compared with the non-dislocation group. Three independent risk factors were found to be related to dislocation: resection of gluteus medius (odds ratio (OR) 3.68 (95% confidence interval (CI) 1.24 to 19.70); p = 0.039), vertical shift of COR > 18 mm (OR 24.8 (95% CI 6.23 to 128.00); p = 0.001), and sagittal shift of COR > 20 mm (OR 6.22 (95% CI 1.33 to 32.2); p = 0.026). CONCLUSION Among the 17 patients who dislocated, 70.3% (n = 12) were anterior dislocations. Three independent risk factors were identified, suggesting the importance of proper restoration of the COR and the role of the gluteus medius in maintaining hip joint stability.Cite this article: Bone Joint J 2022;104-B(10):1180-1188.
Collapse
Affiliation(s)
- Hao Qu
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.,Orthopaedics Research Institute, Zhejiang University, Hangzhou, China.,Key Laboratory of Motor System Disease Research and Precision Therapy of Zhejiang Province, Hangzhou, China.,Diagnosis and Treatment Center of Bone Metastasis, Department of Orthopaedics, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Haochen Mou
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.,Orthopaedics Research Institute, Zhejiang University, Hangzhou, China.,Key Laboratory of Motor System Disease Research and Precision Therapy of Zhejiang Province, Hangzhou, China.,Diagnosis and Treatment Center of Bone Metastasis, Department of Orthopaedics, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Keyi Wang
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.,Orthopaedics Research Institute, Zhejiang University, Hangzhou, China.,Key Laboratory of Motor System Disease Research and Precision Therapy of Zhejiang Province, Hangzhou, China.,Diagnosis and Treatment Center of Bone Metastasis, Department of Orthopaedics, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Huimin Tao
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.,Orthopaedics Research Institute, Zhejiang University, Hangzhou, China.,Key Laboratory of Motor System Disease Research and Precision Therapy of Zhejiang Province, Hangzhou, China.,Diagnosis and Treatment Center of Bone Metastasis, Department of Orthopaedics, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Xin Huang
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.,Orthopaedics Research Institute, Zhejiang University, Hangzhou, China.,Key Laboratory of Motor System Disease Research and Precision Therapy of Zhejiang Province, Hangzhou, China.,Diagnosis and Treatment Center of Bone Metastasis, Department of Orthopaedics, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Xiaobo Yan
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.,Orthopaedics Research Institute, Zhejiang University, Hangzhou, China.,Key Laboratory of Motor System Disease Research and Precision Therapy of Zhejiang Province, Hangzhou, China.,Diagnosis and Treatment Center of Bone Metastasis, Department of Orthopaedics, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Nong Lin
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.,Orthopaedics Research Institute, Zhejiang University, Hangzhou, China.,Key Laboratory of Motor System Disease Research and Precision Therapy of Zhejiang Province, Hangzhou, China.,Diagnosis and Treatment Center of Bone Metastasis, Department of Orthopaedics, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Zhaoming Ye
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.,Orthopaedics Research Institute, Zhejiang University, Hangzhou, China.,Key Laboratory of Motor System Disease Research and Precision Therapy of Zhejiang Province, Hangzhou, China.,Diagnosis and Treatment Center of Bone Metastasis, Department of Orthopaedics, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
9
|
Abstract
AIMS Adverse spinal motion or balance (spine mobility) and adverse pelvic mobility, in combination, are often referred to as adverse spinopelvic mobility (SPM). A stiff lumbar spine, large posterior standing pelvic tilt, and severe sagittal spinal deformity have been identified as risk factors for increased hip instability. Adverse SPM can create functional malposition of the acetabular components and hence is an instability risk. Adverse pelvic mobility is often, but not always, associated with abnormal spinal motion parameters. Dislocation rates for dual-mobility articulations (DMAs) have been reported to be between 0% and 1.1%. The aim of this study was to determine the early survivorship from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) of patients with adverse SPM who received a DMA. METHODS A multicentre study was performed using data from 227 patients undergoing primary total hip arthroplasty (THA), enrolled consecutively. All the patients who had one or more adverse spine or pelvic mobility parameter had a DMA inserted at the time of their surgery. The mean age was 76 years (22 to 93) and 63% were female (n = 145). At a mean of 14 months (5 to 31) postoperatively, the AOANJRR was analyzed for follow-up information. Reasons for revision and types of revision were identified. RESULTS The AOANJRR reported two revisions: one due to infection, and the second due to femoral component loosening. No revisions for dislocation were reported. One patient died with the prosthesis in situ. Kaplan-Meier survival rate was 99.1% (95% confidence interval 98.3 to 100) at 14 months (number at risk 104). CONCLUSION In our cohort of patients undergoing primary THA with one or more factor associated with adverse SPM, DM bearings conferred stability at two years' follow-up. Cite this article: Bone Joint J 2022;104-B(7):820-825.
Collapse
Affiliation(s)
- Rohit Dhawan
- Melbourne Orthopaedic Group, Melbourne, Australia
| | | | - Andrew Shimmin
- Melbourne Orthopaedic Group, Melbourne, Australia.,Monash University, Melbourne, Australia
| |
Collapse
|
10
|
Grothe T, Günther KP, Hartmann A, Blum S, Haselhoff R, Goronzy J. The incidence of adverse local tissue reaction due to head taper corrosion after total hip arthroplasty using V40 taper and 36 mm CoCr head. Bone Joint J 2022; 104-B:852-858. [PMID: 35775169 DOI: 10.1302/0301-620x.104b7.bjj-2021-1769.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Head-taper corrosion is a cause of failure in total hip arthroplasty (THA). Recent reports have described an increasing number of V40 taper failures with adverse local tissue reaction (ALTR). However, the real incidence of V40 taper damage and its cause remain unknown. The aim of this study was to evaluate the long-term incidence of ALTR in a consecutive series of THAs using a V40 taper and identify potentially related factors. METHODS Between January 2006 and June 2007, a total of 121 patients underwent THA using either an uncemented (Accolade I, made of Ti12Mo6Zr2Fe; Stryker, USA) or a cemented (ABG II, made of cobalt-chrome-molybdenum (CoCrMo); Stryker) femoral component, both with a V40 taper (Stryker). Uncemented acetabular components (Trident; Stryker) with crosslinked polyethylene liners and CoCr femoral heads of 36 mm diameter were used in all patients. At a mean folllow-up of 10.8 years (SD 1.1), 94 patients (79%) were eligible for follow-up (six patients had already undergone a revision, 15 had died, and six were lost to follow-up). A total of 85 THAs in 80 patients (mean age 61 years (24 to 75); 47 (56%) were female) underwent clinical and radiological evaluation, including the measurement of whole blood levels of cobalt and chrome. Metal artifact reduction sequence MRI scans of the hip were performed in 71 patients. RESULTS A total of 20 ALTRs were identified on MRI, with an incidence of 26%. Patients with ALTR had significantly higher median Co levels compared with those without ALTR (2.96 μg/l (interquartile range (IQR) 1.35 to 4.98) vs 1.44 μg/l (IQR 0.79 to 2.5); p = 0.019). Radiological evidence of osteolysis was also significantly associated with ALTR (p = 0.014). Median Cr levels were not significantly higher in those with ALTR compared with those without one (0.97 μg/l (IQR 0.72 to 1.9) v 0.67 μg/l (IQR 0.5 to 1.19; p = 0.080). BMI, sex, age, type of femoral component, head length, the inclination of the acetabular component, and heterotopic ossification formation showed no significant relationship with ALTR. CONCLUSION Due to the high incidence of local ALTR in our cohort after more than ten years postoperatively, we recommend regular follow-up investigation even in asymptomatic patients with V40 taper and metal heads. As cobalt levels correlate with ALTR occurrence, routine metal ion screening and consecutive MRI investigation upon elevation could be discussed. Cite this article: Bone Joint J 2022;104-B(7):852-858.
Collapse
Affiliation(s)
- Tim Grothe
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Klaus-Peter Günther
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Albrecht Hartmann
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Sophia Blum
- Department of Radiology, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Richard Haselhoff
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Jens Goronzy
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| |
Collapse
|
11
|
Krull P, Steinbrück A, Grimberg AW, Melsheimer O, Morlock M, Perka C. Modified acetabular component liner designs are not superior to standard liners at reducing the risk of revision : an analysis of 151,096 cementless total hip arthroplasties from the German Arthroplasty Registry. Bone Joint J 2022; 104-B:801-810. [PMID: 35775174 DOI: 10.1302/0301-620x.104b7.bjj-2021-1791.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
AIMS Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). METHODS We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model. RESULTS Median follow-up was 868 days (interquartile range 418 to 1,364). The offset liner design reduced the risk of revision (hazard ratio (HR) 0.68 (95% confidence interval (CI) 0.50 to 0.92)), while the angulated/offset liner increased the risk of revision for mechanical failure (HR 1.81 (95% CI 1.38 to 2.36)). The cumulative incidence of revision was lowest for the offset liner at one and seven years (1.0% (95% CI 0.7 to 1.3) and 1.8% (95% CI 1.0 to 3.0)). No difference was found between standard, lipped, and angulated liner designs. Higher age at index primary THA and an Elixhauser Comorbidity Index greater than 0 increased the revision risk in the first year after surgery. Implantation of a higher proportion of a single design of liner in a hospital reduced revision risk slightly but significantly (p = 0.001). CONCLUSION The use of standard acetabular component liners remains a good choice in primary uncemented THA, as most modified liner designs were not associated with a reduced risk of revision for mechanical failure. Offset liner designs were found to be beneficial and angulated/offset liner designs were associated with higher risks of revision. Cite this article: Bone Joint J 2022;104-B(7):801-810.
Collapse
Affiliation(s)
- Paula Krull
- Charite - Center for Musculosceletal Surgery, Berlin, Germany
| | - Arnd Steinbrück
- German Arthroplasty Registry (EPRD Deutsches Endoprothesenregister), Berlin, Germany
| | - Alexander W Grimberg
- German Arthroplasty Registry (EPRD Deutsches Endoprothesenregister), Berlin, Germany
| | - Oliver Melsheimer
- German Arthroplasty Registry (EPRD Deutsches Endoprothesenregister), Berlin, Germany
| | - Michael Morlock
- Institute of Biomechanics, Hamburg University of Technology, Hamburg, Germany
| | - Carsten Perka
- Charite - Center for Musculosceletal Surgery, Berlin, Germany
| |
Collapse
|
12
|
Kuijpers MFL, Colo E, Schmitz MWJL, Hannink G, Rijnen WHC, Schreurs BW. The outcome of subsequent revisions after primary total hip arthroplasty in 1,049 patients aged under 50 years : a single-centre cohort study with a follow-up of more than 30 years. Bone Joint J 2022; 104-B:368-375. [PMID: 35227093 DOI: 10.1302/0301-620x.104b3.bjj-2021-0904.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aim of this study was to determine the outcome of all primary total hip arthroplasties (THAs) and their subsequent revision procedures in patients aged under 50 years performed at our institution. METHODS All 1,049 primary THAs which were undertaken in 860 patients aged under 50 years between 1988 and 2018 in our tertiary care institution were included. We used cemented implants in both primary and revision surgery. Impaction bone grafting was used in patients with acetabular or femoral bone defects. Kaplan-Meier analyses were used to determine the survival of primary and revision THA with the endpoint of revision for any reason, and of revision for aseptic loosening. RESULTS The mean age of the patients at the time of the initial THA was 38.6 years (SD 9.3). The mean follow-up of the THA was 8.7 years (2.0 to 31.5). The rate of survival for all primary THAs, acetabular components only, and femoral components only at 20 years' follow-up with the endpoint of revision for any reason, was 66.7% (95% confidence interval (CI) 60.5 to 72.2), 69.1% (95% CI 63.0 to 74.4), and 83.2% (95% CI 78.1 to 87.3), respectively. A total of 138 revisions were performed. The mean age at the time of revision was 48.2 years (23 to 72). Survival of all subsequent revision procedures, revised acetabular, and revised femoral components at 15 years' follow-up with the endpoint of revision for any reason was 70.3% (95% CI 56.1 to 80.7), 69.7% (95% CI 54.3 to 80.7), and 76.2% (95% CI 57.8 to 87.4), respectively. A Girdlestone excision arthroplasty was required in six of 860 patients (0.7%). CONCLUSION The long-term outcome of cemented primary and subsequent revision THA is promising in these young patients. We showed that our philosophy of using impaction bone grafting in patients with acetabular and femoral defects is a very suitable option when treating young patients. Surgeons should realize that knowledge of the outcome of subsequent revision surgery, which is inevitable in young patients, must be communicated to this group of patients prior to their initial THA. Cite this article: Bone Joint J 2022;104-B(3):368-375.
Collapse
Affiliation(s)
- Martijn F L Kuijpers
- Department of Orthopaedics, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands.,Dutch Arthroplasty Register (Landelijke Registratie Orthopedische Implantaten), 's Hertogenbosch, The Netherlands
| | - Ena Colo
- Department of Orthopaedics, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Marloes W J L Schmitz
- Department of Orthopaedics, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Gerjon Hannink
- Department of Operating Rooms, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Wim H C Rijnen
- Department of Orthopaedics, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - B Willem Schreurs
- Department of Orthopaedics, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands.,Dutch Arthroplasty Register (Landelijke Registratie Orthopedische Implantaten), 's Hertogenbosch, The Netherlands
| |
Collapse
|
13
|
Gani MH, Zahoor U, Hanna SA, Scott G. Metal-on-metal hip resurfacing arthroplasty provides excellent long-term survivorship and function in patients with a good-sized femoral head : results of a single, non-designer surgeon's cohort. Bone Jt Open 2022; 3:68-76. [PMID: 35045731 PMCID: PMC9047081 DOI: 10.1302/2633-1462.31.bjo-2021-0135.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Aims To establish the survivorship, function, and metal ion levels in an unselected series of metal-on-metal hip resurfacing arthroplasties (HRAs) performed by a non-designer surgeon. Methods We reviewed 105 consecutive HRAs in 83 patients, performed by a single surgeon, at a mean follow-up of 14.9 years (9.3 to 19.1). The cohort included 45 male and 38 female patients, with a mean age of 49.5 years (SD 12.5) Results At the time of review 13 patients with 15 hips had died from causes unrelated to the hip operation, and 14 hips had undergone revision surgery, giving an overall survival rate of rate of 86.7% (95% confidence interval (CI) 84.2 to 89.1). The survival rate in men was 97.7% (95% CI 96.3 to 98.9) and in women was 73.4% (95% CI 70.6 to 75.1). The median head size of the failed group was 42 mm (interquartile range (IQR) 42 to 44), and in the surviving group was 50 mm (IQR 46 to 50). In all, 13 of the 14 revised hips had a femoral component measuring ≤ 46 mm. The mean blood levels of cobalt and chromium ions were 26.6 nmol/l (SD 24.5) and 30.6 nmol/l (SD 15.3), respectively. No metal ion levels exceeded the safe limit. The mean Oxford Hip Score was 41.5 (SD 8.9) and Harris Hip Score was 89.9 (14.8). In the surviving group, four patients had radiolucent lines around the stem of the femoral component, and one had lysis around the acetabular component; eight hips demonstrated heterotopic ossification. Conclusion Our results confirm the existing understanding that HRA provides good long-term survival and function in patients with adequate-sized femoral heads. This is evidenced by a 97.7% survival rate among men (larger heads) in our series at a mean follow-up of 14.9 years. Failure is closely related to head sizes ≤ 46 cm. Cite this article: Bone Jt Open 2022;3(1):68–76.
Collapse
Affiliation(s)
- M Haseeb Gani
- Department of Orthopaedics, The Royal London Hospital, London, UK
| | - Ubaid Zahoor
- Department of Orthopaedics, The Royal London Hospital, London, UK
| | - Sammy A Hanna
- Department of Orthopaedics, The Royal London Hospital, London, UK
| | - Gareth Scott
- Department of Orthopaedics, The Royal London Hospital, London, UK.,Barts and the London School of Medicine and Dentistry, London, UK
| |
Collapse
|
14
|
Abstract
Dislocation following total hip arthroplasty (THA) is a well-known and potentially devastating complication. Clinicians have used many strategies in attempts to prevent dislocation since the introduction of THA. While the importance of postoperative care cannot be ignored, particular emphasis has been placed on preoperative planning in the prevention of dislocation. The strategies have progressed from more traditional approaches, including modular implants, the size of the femoral head, and augmentation of the offset, to newer concepts, including patient-specific component positioning combined with computer navigation, robotics, and the use of dual-mobility implants. As clinicians continue to pursue improved outcomes and reduced complications, these concepts will lay the foundation for future innovation in THA and ultimately improved outcomes. Cite this article: Bone Joint J 2022;104-B(1):8-11.
Collapse
Affiliation(s)
- Joshua Wright-Chisem
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - Ameer M Elbuluk
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - David J Mayman
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - Seth A Jerabek
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - Peter K Sculco
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - Jonathan M Vigdorchik
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| |
Collapse
|
15
|
Divecha HM, O'Neill TW, Lunt M, Board TN. The effect of cemented acetabular component geometry on the risk of revision for instability or loosening : a study of 224,874 primary hip arthroplasties from the National Joint Registry. Bone Joint J 2021; 103-B:1669-1677. [PMID: 34719277 DOI: 10.1302/0301-620x.103b11.bjj-2021-0061.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS To determine if primary cemented acetabular component geometry (long posterior wall (LPW), hooded, or offset reorientating) influences the risk of revision total hip arthroplasty (THA) for instability or loosening. METHODS The National Joint Registry (NJR) dataset was analyzed for primary THAs performed between 2003 and 2017. A cohort of 224,874 cemented acetabular components were included. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using log-binomial regression adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking, and prosthetic head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death. RESULTS The distribution of acetabular component geometries was: LPW 81.2%; hooded 18.7%; and offset reorientating 0.1%. There were 3,313 (1.5%) revision THAs performed, of which 815 (0.4%) were for instability and 838 (0.4%) were for loosening. Compared to the LPW group, the adjusted subhazard ratio of revision for instability in the hooded group was 2.31 (p < 0.001) and 4.12 (p = 0.047) in the offset reorientating group. Likewise, the subhazard ratio of revision for loosening was 2.65 (p < 0.001) in the hooded group and 13.61 (p < 0.001) in the offset reorientating group. A time-varying subhazard ratio of revision for instability (hooded vs LPW) was found, being greatest within the first three months. CONCLUSION This registry-based study confirms a significantly higher risk of revision after cemented THA for instability and for loosening when a hooded or offset reorientating acetabular component is used, compared to a LPW component. Further research is required to clarify if certain patients benefit from the use of hooded or offset reorientating components, but we recommend caution when using such components in routine clinical practice. Cite this article: Bone Joint J 2021;103-B(11):1669-1677.
Collapse
Affiliation(s)
- Hiren M Divecha
- Centre for Hip Surgery, Wrightington Hospital, Wrightington, Wigan and Leigh NHS Foundation Trust, Wigan, UK
| | - Terence W O'Neill
- Centre for Epidemiology Versus Arthritis, The University of Manchester, Manchester, UK.,NIHR Manchester Biomedical Research Centre, Manchester Academic Health Science Centre, Central Manchester University Hospitals NHS Foundation Trust, Manchester, UK.,Rheumatology, Salford Royal NHS Foundation Trust, Salford, UK
| | - Mark Lunt
- Centre for Epidemiology Versus Arthritis, The University of Manchester, Manchester, UK
| | - Tim N Board
- Centre for Hip Surgery, Wrightington Hospital, Wrightington, Wigan and Leigh NHS Foundation Trust, Wigan, UK
| |
Collapse
|
16
|
Abstract
Aims Prior studies have identified that malseating of a modular dual mobility liner can occur, with previous reported incidences between 5.8% and 16.4%. The aim of this study was to determine the incidence of malseating in dual mobility implants at our institution, assess for risk factors for liner malseating, and investigate whether liner malseating has any impact on clinical outcomes after surgery. Methods We retrospectively reviewed the radiographs of 239 primary and revision total hip arthroplasties with a modular dual mobility liner. Two independent reviewers assessed radiographs for each patient twice for evidence of malseating, with a third observer acting as a tiebreaker. Univariate analysis was conducted to determine risk factors for malseating with Youden’s index used to identify cut-off points. Cohen’s kappa test was used to measure interobserver and intraobserver reliability. Results In all, 12 liners (5.0%), including eight Stryker (6.8%) and four Zimmer Biomet (3.3%), had radiological evidence of malseating. Interobserver reliability was found to be 0.453 (95% confidence interval (CI) 0.26 to 0.64), suggesting weak inter-rater agreement, with strong agreement being greater than 0.8. We found component size of 50 mm or less to be associated with liner malseating on univariate analysis (p = 0.031). Patients with malseated liners appeared to have no associated clinical consequences, and none required revision surgery at a mean of 14 months (1.4 to 99.2) postoperatively. Conclusion The incidence of liner malseating was 5.0%, which is similar to other reports. Component size of 50 mm or smaller was identified as a risk factor for malseating. Surgeons should be aware that malseating can occur and implant design changes or changes in instrumentation should be considered to lower the risk of malseating. Although further follow-up is needed, it remains to be seen if malseating is associated with any clinical consequences. Cite this article: Bone Jt Open 2021;2(10):858–864.
Collapse
Affiliation(s)
- Jonathan Guntin
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Darren Plummer
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Craig Della Valle
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Anne DeBenedetti
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Denis Nam
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| |
Collapse
|
17
|
Bergiers S, Hothi H, Henckel J, Di Laura A, Belzunce M, Skinner J, Hart A. The in vivo location of edge-wear in hip arthroplasties : combining pre-revision 3D CT imaging with retrieval analysis. Bone Joint Res 2021; 10:639-649. [PMID: 34605661 PMCID: PMC8559968 DOI: 10.1302/2046-3758.1010.bjr-2021-0132.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Aims Acetabular edge-loading was a cause of increased wear rates in metal-on-metal hip arthroplasties, ultimately contributing to their failure. Although such wear patterns have been regularly reported in retrieval analyses, this study aimed to determine their in vivo location and investigate their relationship with acetabular component positioning. Methods 3D CT imaging was combined with a recently validated method of mapping bearing surface wear in retrieved hip implants. The asymmetrical stabilizing fins of Birmingham hip replacements (BHRs) allowed the co-registration of their acetabular wear maps and their computational models, segmented from CT scans. The in vivo location of edge-wear was measured within a standardized coordinate system, defined using the anterior pelvic plane. Results Edge-wear was found predominantly along the superior acetabular edge in all cases, while its median location was 8° (interquartile range (IQR) -59° to 25°) within the anterosuperior quadrant. The deepest point of these scars had a median location of 16° (IQR -58° to 26°), which was statistically comparable to their centres (p = 0.496). Edge-wear was in closer proximity to the superior apex of the cups with greater angles of acetabular inclination, while a greater degree of anteversion influenced a more anteriorly centred scar. Conclusion The anterosuperior location of edge-wear was comparable to the degradation patterns observed in acetabular cartilage, supporting previous findings that hip joint forces are directed anteriorly during a greater portion of walking gait. The further application of this novel method could improve the current definition of optimal and safe acetabular component positioning. Cite this article: Bone Joint Res 2021;10(10):639–649.
Collapse
Affiliation(s)
- Sean Bergiers
- Institute of Orthopaedics and Musculoskeletal Science, University College London, London, UK
| | - Harry Hothi
- Institute of Orthopaedics and Musculoskeletal Science, University College London, London, UK.,Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| | - Johann Henckel
- Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| | - Anna Di Laura
- Institute of Orthopaedics and Musculoskeletal Science, University College London, London, UK.,Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| | | | - John Skinner
- Institute of Orthopaedics and Musculoskeletal Science, University College London, London, UK.,Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| | - Alister Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, London, UK.,Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| |
Collapse
|