1
|
Wiputra H, Matsumoto S, Wagenseil JE, Braverman AC, Voeller RK, Barocas VH. Statistical shape representation of the thoracic aorta: accounting for major branches of the aortic arch. Comput Methods Biomech Biomed Engin 2023; 26:1557-1571. [PMID: 36165506 PMCID: PMC10040462 DOI: 10.1080/10255842.2022.2128672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 08/24/2022] [Accepted: 09/11/2022] [Indexed: 11/03/2022]
Abstract
Statistical shape modeling (SSM) is an emerging tool for risk assessment of thoracic aortic aneurysm. However, the head branches of the aortic arch are often excluded in SSM. We introduced an SSM strategy based on principal component analysis that accounts for aortic branches and applied it to a set of patient scans. Computational fluid dynamics were performed on the reconstructed geometries to identify the extent to which branch model accuracy affects the calculated wall shear stress (WSS) and pressure. Surface-averaged and location-specific values of pressure did not change significantly, but local WSS error was high near branches when inaccurately modeled.
Collapse
Affiliation(s)
- Hadi Wiputra
- Department of Biomedical Engineering, University of Minnesota
| | - Shion Matsumoto
- Department of Biomedical Engineering, University of Michigan
| | | | - Alan C. Braverman
- Department of Medicine, Cardiovascular Division, Washington University School of Medicine
| | | | | |
Collapse
|
2
|
Gatti V, Nauleau P, Karageorgos GM, Shim JJ, Ateshian GA, Konofagou EE. Modeling Pulse Wave Propagation Through a Stenotic Artery With Fluid Structure Interaction: A Validation Study Using Ultrasound Pulse Wave Imaging. J Biomech Eng 2021; 143:031005. [PMID: 33030208 PMCID: PMC7872000 DOI: 10.1115/1.4048708] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 09/01/2020] [Indexed: 11/08/2022]
Abstract
Pulse wave imaging (PWI) is an ultrasound-based method that allows spatiotemporal mapping of the arterial pulse wave propagation, from which the local pulse wave velocity (PWV) can be derived. Recent reports indicate that PWI can help the assessment of atherosclerotic plaque composition and mechanical properties. However, the effect of the atherosclerotic plaque's geometry and mechanics on the arterial wall distension and local PWV remains unclear. In this study, we investigated the accuracy of a finite element (FE) fluid-structure interaction (FSI) approach to predict the velocity of a pulse wave propagating through a stenotic artery with an asymmetrical plaque, as quantified with PWI method. Experiments were designed to compare FE-FSI modeling of the pulse wave propagation through a stenotic artery against PWI obtained with manufactured phantom arteries made of polyvinyl alcohol (PVA) material. FSI-generated spatiotemporal maps were used to estimate PWV at the plaque region and compared it to the experimental results. Velocity of the pulse wave propagation and magnitude of the wall distension were correctly predicted with the FE analysis. In addition, findings indicate that a plaque with a high degree of stenosis (>70%) attenuates the propagation of the pulse pressure wave. Results of this study support the validity of the FE-FSI methods to investigate the effect of arterial wall structural and mechanical properties on the pulse wave propagation. This modeling method can help to guide the optimization of PWI to characterize plaque properties and substantiate clinical findings.
Collapse
Affiliation(s)
- Vittorio Gatti
- Department of Biomedical Engineering, Columbia University, New York, NY 10027
| | - Pierre Nauleau
- Department of Biomedical Engineering, Columbia University, New York, NY 10027
| | | | - Jay J. Shim
- Department of Mechanical Engineering, Columbia University, New York, NY 10027
| | - Gerard A. Ateshian
- Department of Mechanical Engineering, Columbia University, New York, NY 10027
| | - Elisa E. Konofagou
- Department of Biomedical Engineering, Columbia University, New York, NY 10027; Department of Radiology, Columbia University, 351 Engineering Terrace, Mail Code 8904, New York, NY 10027
| |
Collapse
|
3
|
Khamdaeng T, Terdtoon P. Regional pulse wave velocity and stress in aneurysmal arch-shaped aorta. Biomed Mater Eng 2018; 29:527-549. [PMID: 30282348 DOI: 10.3233/bme-181007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The pulse wave velocity (PWV) has been shown to be associated with the properties of blood vessel and a cardiovascular risk factor such as aneurysm. The global PWV estimation is applied in conventional clinical diagnosis. However, the geometry of blood vessel changes along the wave traveling path and the global PWV estimation may not always detect regional wall changes resulting from cardiovascular diseases. In this study, a fluid structure interaction (FSI) analysis was applied on arch-shaped aortas with and without aneurysm aimed at determining the effects of the number of aneurysm, aneurysm size and the modulus ratio (aneurysm to wall modulus) on the pulse wave propagation and velocity. The characterization for each stage of aneurysmal aorta was simulated by progressively increasing aortic stiffness and aneurysm size. The pulse wave propagations and velocities were estimated from the two-dimensional spatial-temporal plot of the normalized wall displacement based on elastic deformation. The descending forward and arch reflected PWVs of aneurysmal aortic arch models were found up to 9.7% and 122.8%, respectively, deviate from the PWV of non-aneurysmal aortic arch model. The PWV patterns and magnitudes can be used to distinguish the characterization of the normal and aneurysmal aortic walls and shown to be relevant regional markers utilized in clinical diagnosis.
Collapse
Affiliation(s)
- Tipapon Khamdaeng
- Department of Agricultural Engineering, Faculty of Engineering and Agro-Industry, Maejo University, Chiang Mai, Thailand
| | - Pradit Terdtoon
- Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
4
|
Li H, Lin K, Shahmirzadi D. FSI Simulations of Pulse Wave Propagation in Human Abdominal Aortic Aneurysm: The Effects of Sac Geometry and Stiffness. Biomed Eng Comput Biol 2016; 7:25-36. [PMID: 27478394 PMCID: PMC4951115 DOI: 10.4137/becb.s40094] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2016] [Revised: 06/28/2016] [Accepted: 07/02/2016] [Indexed: 11/21/2022] Open
Abstract
This study aims to quantify the effects of geometry and stiffness of aneurysms on the pulse wave velocity (PWV) and propagation in fluid–solid interaction (FSI) simulations of arterial pulsatile flow. Spatiotemporal maps of both the wall displacement and fluid velocity were generated in order to obtain the pulse wave propagation through fluid and solid media, and to examine the interactions between the two waves. The results indicate that the presence of abdominal aortic aneurysm (AAA) sac and variations in the sac modulus affect the propagation of the pulse waves both qualitatively (eg, patterns of change of forward and reflective waves) and quantitatively (eg, decreasing of PWV within the sac and its increase beyond the sac as the sac stiffness increases). The sac region is particularly identified on the spatiotemporal maps with a region of disruption in the wave propagation with multiple short-traveling forward/reflected waves, which is caused by the change in boundary conditions within the saccular region. The change in sac stiffness, however, is more pronounced on the wall displacement spatiotemporal maps compared to those of fluid velocity. We conclude that the existence of the sac can be identified based on the solid and fluid pulse waves, while the sac properties can also be estimated. This study demonstrates the initial findings in numerical simulations of FSI dynamics during arterial pulsations that can be used as reference for experimental and in vivo studies. Future studies are needed to demonstrate the feasibility of the method in identifying very mild sacs, which cannot be detected from medical imaging, where the material property degradation exists under early disease initiation.
Collapse
Affiliation(s)
- Han Li
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Kexin Lin
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Danial Shahmirzadi
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| |
Collapse
|
5
|
Li F, He Q, Huang C, Liu K, Shao J, Luo J. High frame rate and high line density ultrasound imaging for local pulse wave velocity estimation using motion matching: A feasibility study on vessel phantoms. ULTRASONICS 2016; 67:41-54. [PMID: 26773791 DOI: 10.1016/j.ultras.2015.12.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2015] [Revised: 11/20/2015] [Accepted: 12/28/2015] [Indexed: 06/05/2023]
Abstract
Pulse wave imaging (PWI) is an ultrasound-based method to visualize the propagation of pulse wave and to quantitatively estimate regional pulse wave velocity (PWV) of the arteries within the imaging field of view (FOV). To guarantee the reliability of PWV measurement, high frame rate imaging is required, which can be achieved by reducing the line density of ultrasound imaging or transmitting plane wave at the expense of spatial resolution and/or signal-to-noise ratio (SNR). In this study, a composite, full-view imaging method using motion matching was proposed with both high temporal and spatial resolution. Ultrasound radiofrequency (RF) data of 4 sub-sectors, each with 34 beams, including a common beam, were acquired successively to achieve a frame rate of ∼507 Hz at an imaging depth of 35 mm. The acceleration profiles of the vessel wall estimated from the common beam were used to reconstruct the full-view (38-mm width, 128-beam) image sequence. The feasibility of mapping local PWV variation along the artery using PWI technique was preliminarily validated on both homogeneous and inhomogeneous polyvinyl alcohol (PVA) cryogel vessel phantoms. Regional PWVs for the three homogeneous phantoms measured by the proposed method were in accordance with the sparse imaging method (38-mm width, 32-beam) and plane wave imaging method. Local PWV was estimated using the above-mentioned three methods on 3 inhomogeneous phantoms, and good agreement was obtained in both the softer (1.91±0.24 m/s, 1.97±0.27 m/s and 1.78±0.28 m/s) and the stiffer region (4.17±0.46 m/s, 3.99±0.53 m/s and 4.27±0.49 m/s) of the phantoms. In addition to the improved spatial resolution, higher precision of local PWV estimation in low SNR circumstances was also obtained by the proposed method as compared with the sparse imaging method. The proposed method might be helpful in disease detections through mapping the local PWV of the vascular wall.
Collapse
Affiliation(s)
- Fubing Li
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing 100084, China
| | - Qiong He
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing 100084, China
| | - Chengwu Huang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing 100084, China
| | - Ke Liu
- Division of Electronics and Information Technology, National Institute of Metrology, Beijing 100013, China
| | - Jinhua Shao
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Jianwen Luo
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
6
|
Apostolakis IZ, Nandlall SD, Konofagou EE. Piecewise Pulse Wave Imaging (pPWI) for Detection and Monitoring of Focal Vascular Disease in Murine Aortas and Carotids In Vivo. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:13-28. [PMID: 26168432 PMCID: PMC4703464 DOI: 10.1109/tmi.2015.2453194] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Atherosclerosis and Abdominal Aortic Aneurysms (AAAs) are two common vascular diseases associated with mechanical changes in the arterial wall. Pulse Wave Imaging (PWI), a technique developed by our group to assess and quantify the mechanical properties of the aortic wall in vivo, may provide valuable diagnostic information. This work implements piecewise PWI (pPWI), an enhanced version of PWI designed for focal vascular diseases. Localized, sub-regional PWVs and PWI moduli ( EPWI ) were estimated within 2-4 mm wall segments of murine normal, atherosclerotic and aneurysmal arteries. Overall, stiffness was found to increase in the atherosclerotic cases. The mean sub-regional PWV was found to be 2.57±0.18 m/s for the normal aortas (n = 7) with a corresponding mean EPWI of 43.82±5.86 kPa. A significant increase ( (p ≤ 0.001)) in the group means of the sub-regional PWVs was found between the normal aortas and the aortas of mice on high-fat diet for 20 ( 3.30±0.36 m/s) and 30 weeks ( 3.56±0.29 m/s). The mean of the sub-regional PWVs ( 1.57±0.78 m/s) and EPWI values ( 19.23±15.47 kPa) decreased significantly in the aneurysmal aortas (p ≤ 0.05) . Furthermore, the mean coefficient of determination (r(2)) of the normal aortas was significantly higher (p ≤ 0.05) than those of the aneurysmal and atherosclerotic cases. These findings demonstrated that pPWI may be able to provide useful biomarkers for monitoring focal vascular diseases.
Collapse
Affiliation(s)
| | - Sacha D. Nandlall
- Department of Biomedical Engineering Columbia University, New York, NY 10027 USA
| | - Elisa E. Konofagou
- Departments of Biomedical Engineering and Radiology, Columbia University, New York, NY 10027 USA ()
| |
Collapse
|
7
|
Upadhyay RK. Emerging risk biomarkers in cardiovascular diseases and disorders. J Lipids 2015; 2015:971453. [PMID: 25949827 PMCID: PMC4407625 DOI: 10.1155/2015/971453] [Citation(s) in RCA: 158] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Revised: 02/24/2015] [Accepted: 02/25/2015] [Indexed: 12/16/2022] Open
Abstract
Present review article highlights various cardiovascular risk prediction biomarkers by incorporating both traditional risk factors to be used as diagnostic markers and recent technologically generated diagnostic and therapeutic markers. This paper explains traditional biomarkers such as lipid profile, glucose, and hormone level and physiological biomarkers based on measurement of levels of important biomolecules such as serum ferritin, triglyceride to HDLp (high density lipoproteins) ratio, lipophorin-cholesterol ratio, lipid-lipophorin ratio, LDL cholesterol level, HDLp and apolipoprotein levels, lipophorins and LTPs ratio, sphingolipids, Omega-3 Index, and ST2 level. In addition, immunohistochemical, oxidative stress, inflammatory, anatomical, imaging, genetic, and therapeutic biomarkers have been explained in detail with their investigational specifications. Many of these biomarkers, alone or in combination, can play important role in prediction of risks, its types, and status of morbidity. As emerging risks are found to be affiliated with minor and microlevel factors and its diagnosis at an earlier stage could find CVD, hence, there is an urgent need of new more authentic, appropriate, and reliable diagnostic and therapeutic markers to confirm disease well in time to start the clinical aid to the patients. Present review aims to discuss new emerging biomarkers that could facilitate more authentic and fast diagnosis of CVDs, HF (heart failures), and various lipid abnormalities and disorders in the future.
Collapse
Affiliation(s)
- Ravi Kant Upadhyay
- Department of Zoology, DDU Gorakhpur University, Gorakhpur 273009, India
| |
Collapse
|
8
|
In silico characterization of the effects of size, distribution, and modulus contrast of aortic focal softening on pulse wave propagations. Artery Res 2015. [DOI: 10.1016/j.artres.2015.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
9
|
Cloonan AJ, Shahmirzadi D, Li RX, Doyle BJ, Konofagou EE, McGloughlin TM. 3D-Printed Tissue-Mimicking Phantoms for Medical Imaging and Computational Validation Applications. 3D PRINTING AND ADDITIVE MANUFACTURING 2014; 1:14-23. [PMID: 28804733 PMCID: PMC4981152 DOI: 10.1089/3dp.2013.0010] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Abdominal aortic aneurysm (AAA) is a permanent, irreversible dilation of the distal region of the aorta. Recent efforts have focused on improved AAA screening and biomechanics-based failure prediction. Idealized and patient-specific AAA phantoms are often employed to validate numerical models and imaging modalities. To produce such phantoms, the investment casting process is frequently used, reconstructing the 3D vessel geometry from computed tomography patient scans. In this study the alternative use of 3D printing to produce phantoms is investigated. The mechanical properties of flexible 3D-printed materials are benchmarked against proven elastomers. We demonstrate the utility of this process with particular application to the emerging imaging modality of ultrasound-based pulse wave imaging, a noninvasive diagnostic methodology being developed to obtain regional vascular wall stiffness properties, differentiating normal and pathologic tissue in vivo. Phantom wall displacements under pulsatile loading conditions were observed, showing good correlation to fluid-structure interaction simulations and regions of peak wall stress predicted by finite element analysis. 3D-printed phantoms show a strong potential to improve medical imaging and computational analysis, potentially helping bridge the gap between experimental and clinical diagnostic tools.
Collapse
Affiliation(s)
- Aidan J. Cloonan
- Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering, University of Limerick, Limerick, Ireland
- Irish Centre for Composites Research, Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
- Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
| | - Danial Shahmirzadi
- Ultrasound and Elasticity Imaging Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, New Jersey
| | - Ronny X. Li
- Ultrasound and Elasticity Imaging Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York
| | - Barry J. Doyle
- Intelligent Systems for Medicine Laboratory, School of Mechanical and Chemical Engineering, University of Western Australia, Perth, Australia
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Elisa E. Konofagou
- Ultrasound and Elasticity Imaging Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York
- Department of Radiology, Columbia University, New York, New York
| | - Tim M. McGloughlin
- Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering, University of Limerick, Limerick, Ireland
- Materials and Surface Science Institute, University of Limerick, Limerick, Ireland
- Department of Biomedical Engineering, Khalifa University of Science, Technology & Research, Abu Dhabi, United Arab Emirates
| |
Collapse
|