1
|
Im JE, Jung EY, Lee SS, Min HK. Right anterior mini-thoracotomy aortic valve replacement versus transcatheter aortic valve implantation in octogenarians: a single-center retrospective study. JOURNAL OF YEUNGNAM MEDICAL SCIENCE 2024; 41:96-102. [PMID: 38404057 DOI: 10.12701/jyms.2023.01228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 01/26/2024] [Indexed: 02/27/2024]
Abstract
BACKGROUND The aim of this study was to compare the early outcomes of octogenarians undergoing minimally invasive right anterior mini-thoracotomy aortic valve replacement (RAT-AVR) with those undergoing transcatheter aortic valve implantation (TAVI) for aortic valve disease. METHODS In this single-center retrospective study, data were collected from octogenarians before and after RAT-AVR and TAVI between January 2021 and July 2022. Short-term outcomes, including the length of hospital stay, in-hospital mortality, all-cause mortality, and other major postoperative complications, were compared and analyzed. RESULTS There were no significant differences in in-hospital mortality, stroke, acute kidney dysfunction requiring renal replacement therapy, length of intensive care unit stay, or length of hospital stay. However, the TAVI group had a higher incidence of permanent pacemaker insertion (10% vs. 0%, p=0.54) and paravalvular leaks (75% vs. 0%, p<0.001). CONCLUSION In the present study on octogenarians, both TAVI and RAT-AVR showed comparable short-term results. Although both procedures were considered safe and effective in the selected group, RAT-AVR had a lower incidence of complete atrioventricular block and paravalvular regurgitation.
Collapse
Affiliation(s)
- Ji Eun Im
- Department of Thoracic and Cardiovascular Surgery, Yeungnam University College of Medicine, Daegu, Korea
| | - Eun Yeung Jung
- Department of Thoracic and Cardiovascular Surgery, Yeungnam University College of Medicine, Daegu, Korea
| | - Seok Soo Lee
- Department of Thoracic and Cardiovascular Surgery, Yeungnam University College of Medicine, Daegu, Korea
| | - Ho-Ki Min
- Department of Thoracic and Cardiovascular Surgery, Yeungnam University College of Medicine, Daegu, Korea
| |
Collapse
|
2
|
Kirmani BH, Jones SG, Muir A, Malaisrie SC, Chung DA, Williams RJ, Akowuah E. Limited versus full sternotomy for aortic valve replacement. Cochrane Database Syst Rev 2023; 12:CD011793. [PMID: 38054555 PMCID: PMC10698838 DOI: 10.1002/14651858.cd011793.pub3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/07/2023]
Abstract
BACKGROUND Aortic valve disease is a common condition easily treatable with cardiac surgery. This is conventionally performed by opening the sternum ('median sternotomy') and replacing the valve under cardiopulmonary bypass. Median sternotomy is well tolerated, but as less invasive options become available, the efficacy of limited incisions has been called into question. In particular, the effects of reducing the visibility and surgical access have raised safety concerns with regard to the placement of cannulae, venting of the heart, epicardial wire placement, and de-airing of the heart at the end of the procedure. These difficulties may increase operating times, affecting outcome. The benefits of smaller incisions are thought to include decreased pain; improved respiratory mechanics; reductions in wound infections, bleeding, and need for transfusion; shorter intensive care stay; better cosmesis; and a quicker return to normal activity. This is an update of a Cochrane review first published in 2017, with seven new studies. OBJECTIVES To assess the effects of minimally invasive aortic valve replacement via a limited sternotomy versus conventional aortic valve replacement via median sternotomy in people with aortic valve disease requiring surgical replacement. SEARCH METHODS We performed searches of CENTRAL, MEDLINE and Embase from inception to August 2021, with no language limitations. We also searched two clinical trials registries and manufacturers' websites. We reviewed references of primary studies to identify any further studies of relevance. SELECTION CRITERIA We included randomised controlled trials comparing aortic valve replacement via a median sternotomy versus aortic valve replacement via a limited sternotomy. We excluded trials that performed other minimally invasive incisions such as mini-thoracotomies, port access, transapical, transfemoral or robotic procedures. Although some well-conducted prospective and retrospective case-control and cohort studies exist, these were not included in this review. DATA COLLECTION AND ANALYSIS Two review authors independently assessed trial papers to extract data, assess quality, and identify risk of bias. A third review author provided arbitration where required. We determined the certainty of evidence using the GRADE methodology and summarised results of patient-relevant outcomes in a summary of findings table. MAIN RESULTS The review included 14 trials with 1395 participants. Most studies had at least two domains at high risk of bias. We analysed 14 outcomes investigating the effects of minimally invasive limited upper hemi-sternotomy on aortic valve replacement as compared to surgery performed via full median sternotomy. Upper hemi-sternotomy may have little to no effect on mortality versus full median sternotomy (risk ratio (RR) 0.93, 95% confidence interval (CI) 0.45 to 1.94; 10 studies, 985 participants; low-certainty evidence). Upper hemi-sternotomy for aortic valve replacement may increase cardiopulmonary bypass time slightly, although the evidence is very uncertain (mean difference (MD) 10.63 minutes, 95% CI 3.39 to 17.88; 10 studies, 1043 participants; very low-certainty evidence) and may increase aortic cross-clamp time slightly (MD 6.07 minutes, 95% CI 0.79 to 11.35; 12 studies, 1235 participants; very low-certainty evidence), although the evidence is very uncertain. Most studies had at least two domains at high risk of bias. Postoperative blood loss was probably lower in the upper hemi-sternotomy group (MD -153 mL, 95% CI -246 to -60; 8 studies, 767 participants; moderate-certainty evidence). Low-certainty evidence suggested that there may be no change in pain scores by upper hemi-sternotomy (standardised mean difference (SMD) -0.19, 95% CI -0.43 to 0.04; 5 studies, 649 participants). Upper hemi-sternotomy may result in little to no difference in quality of life (MD 0.03 higher, 95% CI 0 to 0.06 higher; 4 studies, 624 participants; low-certainty evidence). Two studies reporting index admission costs concluded that limited sternotomy may be more costly at index admission in the UK National Health Service (MD 1190 GBP more, 95% CI 420 GBP to 1970 GBP, 2 studies, 492 participants; low-certainty evidence). AUTHORS' CONCLUSIONS The evidence was of very low to moderate certainty. Sample sizes were small and underpowered to demonstrate differences in some outcomes. Clinical heterogeneity was also noted. Considering these limitations, there may be little to no effect on mortality. Differences in extracorporeal support times are uncertain, comparing upper hemi-sternotomy to full sternotomy for aortic valve replacement. Before widespread adoption of the minimally invasive approach can be recommended, there is a need for a well-designed and adequately powered prospective randomised controlled trial. Such a study would benefit from also performing a robust cost analysis. Growing patient preference for minimally invasive techniques merits thorough quality of life analyses to be included as end points, as well as quantitative measures of physiological reserve.
Collapse
Affiliation(s)
- Bilal H Kirmani
- Cardiothoracic Surgery, Liverpool Heart and Chest Hospital, Liverpool, UK
- University of Liverpool, Liverpool, UK
- Liverpool Centre for Cardiovascular Science, Liverpool, UK
| | - Sion G Jones
- Department of Cardiac Surgery, University Hospital Coventry and Warwickshire, Coventry, UK
| | - Andrew Muir
- Cardiothoracic Surgery, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - S Chris Malaisrie
- Division of Cardiac Surgery, Northwestern University, Chicago, IL, USA
| | | | | | - Enoch Akowuah
- Academic Cardiovascular Unit, South Tees Hospitals NHS Foundation Trust, Middlesbrough, UK
- Translational and Clinical Research Institute, Newcastle University, Newcastle, UK
| |
Collapse
|
3
|
Fabre O, Radutoiu M, Carjaliu I, Rebet O, Gautier L, Hysi I. Recent improvement in operative techniques lead to lower pacemaker rate after Perceval implant. Interact Cardiovasc Thorac Surg 2022; 35:6617842. [PMID: 35751610 PMCID: PMC9295764 DOI: 10.1093/icvts/ivac182] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Revised: 02/07/2022] [Accepted: 06/23/2022] [Indexed: 11/25/2022] Open
Abstract
Decrease in the pacemaker rate after Perceval implants in the last 5 years. The left Y-axis shows the percent of permanent cardiac pacemakers implanted. The right Y-axis (in green) shows the number of Perceval valves implanted. ![]()
Collapse
Affiliation(s)
- Olivier Fabre
- Department of Cardiac Surgery of Artois, Centre Hospitalier de Lens et Hôpital Privé de Bois Bernard , Ramsay, Santé, France
| | - Mihai Radutoiu
- Department of Cardiac Surgery of Artois, Centre Hospitalier de Lens et Hôpital Privé de Bois Bernard , Ramsay, Santé, France
| | - Ionut Carjaliu
- Department of Cardiac Surgery of Artois, Centre Hospitalier de Lens et Hôpital Privé de Bois Bernard , Ramsay, Santé, France
| | - Olivier Rebet
- Department of Cardiac Surgery of Artois, Centre Hospitalier de Lens et Hôpital Privé de Bois Bernard , Ramsay, Santé, France
| | - Laurence Gautier
- Department of Cardiac Surgery of Artois, Centre Hospitalier de Lens et Hôpital Privé de Bois Bernard , Ramsay, Santé, France
| | - Ilir Hysi
- Department of Cardiac Surgery of Artois, Centre Hospitalier de Lens et Hôpital Privé de Bois Bernard , Ramsay, Santé, France
| |
Collapse
|
4
|
Servito M, Khoury W, Payne D, Baranchuk A, El Diasty M. Long-term impact of permanent cardiac pacing after surgical aortic valve replacement: systematic review and meta-analysis. Expert Rev Cardiovasc Ther 2022; 20:81-86. [DOI: 10.1080/14779072.2022.2031981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Maria Servito
- Faculty of Medicine, Queen’s University, Kingston, ON, Canada
| | - William Khoury
- Faculty of Medicine, Queen’s University, Kingston, ON, Canada
| | - Darrin Payne
- Division of Cardiac Surgery, Kingston Health Sciences Centre, Kingston, ON, Canada
| | - Adrian Baranchuk
- Division of Cardiology, Kingston Health Sciences Centre, Kingston, ON, Canada
| | - Mohammad El Diasty
- Division of Cardiac Surgery, Kingston Health Sciences Centre, Kingston, ON, Canada
| |
Collapse
|
5
|
Bejko J, Della Barbera M, Valente M, Pettenazzo E, Gregori D, Basso C, Thiene G. Morphologic investigation on Perceval S, a sutureless pericardial valve prosthesis: collagen integrity after collapsing-ballooning and structural valve deterioration at distance. Int J Cardiol 2021; 341:62-67. [PMID: 34324948 DOI: 10.1016/j.ijcard.2021.07.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 07/21/2021] [Accepted: 07/23/2021] [Indexed: 11/16/2022]
Abstract
Perceval S is a self-expandable, stent-mounted bioprosthetic valve (BPV), with glutaraldehyde treated bovine pericardium, processed with homocysteic acid as an anti-calcification treatment. The stent is crimpable but the valve insertion is done surgically via a shorter procedure which does not require sutures. OBJECTIVES: MATERIAL AND METHODS: RESULTS: CONCLUSIONS: Collapsing and ballooning do not alter cusp collagen periodicity. Structural valve deterioration with stenosis, due to dystrophic calcification and fibrous tissue overgrowth, seldom occurred in the mid-term. Glutaraldehyde fixed pericardium has the potential to undergo structural valve deterioration with time, similar to well-known BPV failure. This supports the recommendation to pursue improvement of tissue valve treatment with enhanced durability.
Collapse
Affiliation(s)
- Jonida Bejko
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Cardiovascular Pathology, University of Padua Medical School, Padua, Italy
| | - Mila Della Barbera
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Cardiovascular Pathology, University of Padua Medical School, Padua, Italy
| | - Marialuisa Valente
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Cardiovascular Pathology, University of Padua Medical School, Padua, Italy
| | - Elena Pettenazzo
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Cardiovascular Pathology, University of Padua Medical School, Padua, Italy
| | - Dario Gregori
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Cardiovascular Pathology, University of Padua Medical School, Padua, Italy
| | - Cristina Basso
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Cardiovascular Pathology, University of Padua Medical School, Padua, Italy
| | - Gaetano Thiene
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Cardiovascular Pathology, University of Padua Medical School, Padua, Italy.
| |
Collapse
|
6
|
Baghai M, Glauber M, Fontaine R, Castillo JC, Walker AH, Livi U, Montiel J, Royse A, Bisleri G, Pacini D, Argano V, Roumy A, Asimakopoulos G, Solinas M. Clinical outcomes after implantation of a sutureless aortic bioprosthesis with concomitant mitral valve surgery: the SURE-AVR registry. J Cardiothorac Surg 2021; 16:154. [PMID: 34053453 PMCID: PMC8165775 DOI: 10.1186/s13019-021-01523-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Accepted: 05/07/2021] [Indexed: 11/22/2022] Open
Abstract
Background Early treatment of aortic valve stenosis is recommended in eligible symptomatic patients with severe aortic valve stenosis who would otherwise have a poor prognosis. The sutureless aortic valve bioprosthesis offers an alternative to standard aortic valve replacement with a sutured valve, but limited data are available in patients who have undergone multiple valve procedures involving the new, sutureless technology. We sought to investigate outcomes in high operative risk patients with previous or concomitant valve surgery who were implanted with a sutureless valve. Methods SURE-AVR is an ongoing, prospective, multinational registry of patients undergoing aortic valve replacement. In-hospital and post-discharge outcomes up to 5 years were collected. Results The study population comprised 78 patients (mean ± SD: age 73.6 ± 7.6 years, logistic EuroSCORE 18.0 ± 17.5) enrolled at 13 sites who presented for concomitant or previous mitral valve repair (n = 45) or replacement (n = 33), with or without additional concomitant procedures, and were implanted with a sutureless valve. Mean ± SD overall aortic cross-clamp time was 109 ± 41 min and cardiopulmonary bypass time was 152 ± 49 min. Mean ± SD aortic pressure gradients decreased from 37.6 ± 17.7 mmHg preoperatively to 13.0 ± 5.7 mmHg at hospital discharge, and peak aortic pressure gradient from 61.5 ± 28.7 to 23.4 ± 10.6 mmHg. Early events included 1 death, 1 transient ischaemic attack, and 1 bleed (all 1.3%); a permanent pacemaker implantation was required in 6 patients (7.7%), and 2 reoperations (not valve related) (2.6%) took place. Over a median follow-up of 55.5 months (Q1 13.4, Q3 68.6), 12 patients died (6 cardiovascular and 6 non-cardiovascular, both 2.1% per patient-year). Five-year survival was 81.3%. Late paravalvular leak occurred in 2 patients (0.7% per patient-year) and permanent pacemaker implantation was required in 3 patients (0.1% per patient-year). There was no apparent rise in mean or peak aortic pressure gradient over the study. Conclusions These results suggest that the sutureless implant is a technically feasible procedure during mitral surgery and is associated with good clinical outcomes.
Collapse
Affiliation(s)
- Max Baghai
- Department of Cardiovascular Medicine, King's College Hospital, Brixton, London, SE5 9RS, UK.
| | - Mattia Glauber
- U.O. Cardiochirurgia Mininvasiva, Istituto Clinico Sant'Ambrogio, Milan, Italy
| | | | | | - Antony H Walker
- Cardiothoracic Surgery, Blackpool Teaching Hospitals NHS Foundation Trust, Blackpool, UK
| | - Ugolino Livi
- Cardiochirurgia, Az. Osp. Univ. S. Maria della Misericordia, Udine, Italy
| | - José Montiel
- Cirurgia Cardiaca, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Alistair Royse
- Cardiovascular department, The University of Melbourne, Melbourne, Australia
| | | | - Davide Pacini
- Cardiochiurgia, Policlinico Sant'Orsola, Bologna, Italy
| | - Vincenzo Argano
- U.O.C. Cardiochirurgia, AOU Policlinico "Paolo Giaccone", Palermo, Italy
| | - Aurelien Roumy
- Service de chirurgie cardio-vasculaire, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | | | - Marco Solinas
- U.O.C Cardiochirurgia Adulti, Ospedale del Cuore G. Pasquinucci, Fondazione Toscana Fabriele Monasterio, Massa, Italy
| | | |
Collapse
|
7
|
Mugnai G, Moran D, Nijs J, Chierchia GB, Velagic V, Ströker E, Hunuk B, Czapla J, Brugada P, La Meir M, de Asmundis C. Electrocardiographic and clinical predictors of permanent pacemaker insertion following Perceval sutureless aortic valve implantation. J Electrocardiol 2019; 56:10-14. [DOI: 10.1016/j.jelectrocard.2019.06.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 05/29/2019] [Accepted: 06/12/2019] [Indexed: 01/01/2023]
|
8
|
Grant JK, Braghiroli J, Panakos A, De Marchena E. Balloon aortic valvuloplasty: Treatment of rapid deployment aortic valve replacement complicated by a paravalvular leak. J Card Surg 2019; 34:738-741. [PMID: 31212381 DOI: 10.1111/jocs.14096] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Accepted: 05/15/2019] [Indexed: 11/28/2022]
Abstract
The Edwards Intuity Elite valve system was designed to facilitate minimally invasive surgery and streamline complex aortic valve replacements and has since gained more popularity. Despite the superior results shown with rapid deployment aortic valve replacement (RDAVR) utilizing this valve system, paravalvular leaks (PVL), as a complication, remains a concern. Currently, there is no universally agreed single treatment option. A 53-year-old male with a history of well-controlled diabetes mellitus and hypertension presented to the emergency room with a 1-month history of angina, syncope on exertion and dyspnea. On further workup, he was found to have severe aortic stenosis in the setting of a bicuspid aortic valve, with non-obstructive coronary artery disease. He proceeded to urgent RDAVR with a 23 mm Edwards Intuity Valve. Six months post-RDAVR he re-presented with dyspnea on exertion and near syncopal episodes. Postoperative transthoracic and transesophageal echocardiography revealed moderate to severe PVL posterior to the prosthetic aortic valve. Balloon valvuloplasty with a 25 mm True Balloon was performed. Resolution of the PVL was confirmed postprocedure both by angiography and echocardiography. The patient was followed for 1 year and remained symptom-free with evidence of mild PVL on surveillance echocardiography. In conclusion, multiple treatment options for RDAVR complicated by PVL exist; however mid to long-term outcome data are lacking. We presented one such case successfully treated with balloon aortic valvuloplasty.
Collapse
Affiliation(s)
- Jelani K Grant
- Department of Medicine, University of Miami/Jackson Memorial Hospital, Miami, Florida
| | - Joao Braghiroli
- Department of Medicine, Cardiovascular Division, University of Miami, Miami, Florida
| | - Andrew Panakos
- Department of Medicine, Cardiovascular Division, University of Miami, Miami, Florida
| | - Eduardo De Marchena
- Department of Medicine, Cardiovascular Division, University of Miami, Miami, Florida
| |
Collapse
|
9
|
Mujtaba SS, Ledingham SM, Shah AR, Pillay T, Schueler S, Clark S. Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients. Braz J Cardiovasc Surg 2019; 33:122-128. [PMID: 29898140 PMCID: PMC5985837 DOI: 10.21470/1678-9741-2017-0088] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 07/22/2017] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVE The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. METHODS From January 2011 to December 2016, 763 patients underwent aortic valve replacement with bioprostheses; of these, 139 received a Perceval S sutureless valve (Group A) and 624 received a Perimount Magna Ease valve (Group B). These groups were further divided into A1 (isolated Perceval AVR), A2 (Perceval AVR with coronary artery bypass grafting [CABG]), B1 (isolated conventional stented bioprosthesis), and B2 (conventional stented bioprosthesis + CABG). RESULTS Patients in Group A were older (mean 74 years vs. 71 years; P<0.0001), predominantly women (53% vs. 32%; P<0.0001), had a higher logistic EuroSCORE (3.26 vs. 2.43; P<0.001), more preoperative atrial fibrillation (20% vs. 13%; P=0.03), and had a lower reopening rate for bleeding (2.1% vs. 6.7%; P=0.04). Compared to Group B1, Group A1 had shorter cross-clamp (mean 40 min vs. 57 min; P≤0.0001) and bypass times (mean 63 min vs. mean 80 min; P=0.02), and they bled less postoperatively (mean 295 ml vs. mean 393 ml; P=0.002). The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. CONCLUSION In our retrospective study of 763 patients, sutureless valve group patients are older, mostly women, more symptomatic preoperatively, and have higher logistic EuroSCORE. They have shorter cross-clamp and bypass times, less postoperative bleeding, and reduced incidence of reopening. Further studies are needed to evaluate the clinical benefits in short, mid, and long-terms.
Collapse
Affiliation(s)
- Syed Saleem Mujtaba
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Simon M Ledingham
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Asif Raza Shah
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Thasee Pillay
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Stephan Schueler
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Stephen Clark
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| |
Collapse
|
10
|
Dalia AA, Hunter C, Woodward E, Dudzinski D, Andritsos M, Essandoh M, Andrawes M. Transesophageal Echocardiographic Assessment of the Sutureless Perceval Aortic Valve. J Cardiothorac Vasc Anesth 2018; 32:2592-2598. [PMID: 29804686 DOI: 10.1053/j.jvca.2018.04.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2018] [Indexed: 11/11/2022]
Affiliation(s)
- Adam A Dalia
- Department of Anesthesiology, Pain Medicine, and Critical Care, The Massachusetts General Hospital, Harvard Medical School, Boston, MA.
| | - Caroline Hunter
- Department of Anesthesiology, Pain Medicine, and Critical Care, The Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Elliot Woodward
- Department of Anesthesiology, Pain Medicine, and Critical Care, The Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - David Dudzinski
- Department of Cardiology, The Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Michael Andritsos
- Department of Anesthesiology, The Ohio State University Wexner Medical Center, Columbus, OH
| | - Michael Essandoh
- Department of Anesthesiology, The Ohio State University Wexner Medical Center, Columbus, OH
| | - Michael Andrawes
- Department of Anesthesiology, Pain Medicine, and Critical Care, The Massachusetts General Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
11
|
Mujtaba SS, Ledingham S, Shah AR, Clark S, Pillay T, Schueler S. Early Clinical Results of Perceval Sutureless Aortic Valve in 139 Patients: Freeman Experience. Braz J Cardiovasc Surg 2018; 33:8-14. [PMID: 29617495 PMCID: PMC5873786 DOI: 10.21470/1678-9741-2017-0087] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 07/28/2017] [Indexed: 12/03/2022] Open
Abstract
Objective The aim of this retrospective study is to evaluate the safety and performance
of the Perceval sutureless valve in patients undergoing aortic valve
replacement. We report the 30-day clinical outcomes of 139 patients. Methods From January 2014 to December 2016, 139 patients underwent sutureless aortic
valve replacement. Their operation notes, National Adult Cardiac Surgery
Database and perioperative transoesophageal echocardiography findings were
studied retrospectively. Results Ninety-two patients underwent isolated aortic valve replacement (group A)
with Perceval valve and 47 patients had combined procedures of aortic valve
replacement and coronary artery bypass grafting (group B). The patients
received a size S (n=23), M (n=39), L (n=42) or XL (n=35) prosthesis.
Perceval valve was successfully implanted in 135 (97.1%) patients. Mean
cross-clamping time and bypass time were 40 and 63 minutes for isolated
cases, while 68 and 107 minutes for combined cases. Three (2.1%) patients
died within 30 days. Four patients suffered stroke and 5 patients went into
acute renal failure. Median intensive care unit and hospital stay was 2 and
8.5, respectively. Four valves were explanted due to significant
paravalvular leak after surgery. Five patients had permanent pacemaker as a
result of complete heart block and mean postoperative drainage was 295 mL
for isolated case and 457 mL for combined cases. The mean gradient across
Perceval valve was 12.5 mmHg while its effective orifice area was 1.5
cm2. Conclusion Early postoperative results showed that Perceval valve is safe. Further
follow up is needed to evaluate the long-term outcome with this
bioprosthesis.
Collapse
Affiliation(s)
- Syed Saleem Mujtaba
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Simon Ledingham
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Asif Raza Shah
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Stephen Clark
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Thasee Pillay
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| | - Stephan Schueler
- Department of Cardiothoracic Surgery, Freeman Hospital, Freeman Road, United Kingdom of Great Britain and Northern Ireland
| |
Collapse
|
12
|
Use of the Perceval Sutureless Valve in Active Prosthetic Aortic Valve Endocarditis. Ann Thorac Surg 2018; 105:1168-1174. [DOI: 10.1016/j.athoracsur.2017.11.031] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2017] [Revised: 11/07/2017] [Accepted: 11/08/2017] [Indexed: 11/22/2022]
|
13
|
Schlömicher M, Taghiyev Z, AlJabery Y, Haldenwang PL, Zumholz M, Sikole M, Useini D, Naraghi H, Moustafine V, Bechtel M, Strauch JT. Rapid deployment aortic valve replacement in a minimal access setting: intermediate clinical and echocardiographic outcomes†. Eur J Cardiothorac Surg 2018; 54:354-360. [DOI: 10.1093/ejcts/ezy023] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Accepted: 01/07/2018] [Indexed: 11/12/2022] Open
Affiliation(s)
- Markus Schlömicher
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Zulfugar Taghiyev
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Yazan AlJabery
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Peter Lukas Haldenwang
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Michael Zumholz
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Magdalena Sikole
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Dritan Useini
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Hamid Naraghi
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Vadim Moustafine
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Matthias Bechtel
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Justus Thomas Strauch
- Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| |
Collapse
|
14
|
Hanedan MO, Yuruk MA, Parlar AI, Ziyrek U, Arslan AK, Sayar U, Mataraci I. Sutureless versus Conventional Aortic Valve Replacement: Outcomes in 70 High-Risk Patients Undergoing Concomitant Cardiac Procedures. Tex Heart Inst J 2018; 45:11-16. [PMID: 29556145 DOI: 10.14503/thij-16-6092] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
In elderly, high-risk surgical patients, sutureless aortic valve replacement (AVR) can often be an alternative to conventional AVR; shorter aortic cross-clamp and cardiopulmonary bypass times are the chief advantages. We compared the outcomes of sutureless AVR with those of conventional AVR in 70 elderly patients who underwent concomitant cardiac surgical procedures. We retrospectively analyzed the cases of 42 men and 28 women (mean age, 70.4 ± 10.3 yr; range, 34-93 yr) who underwent cardiac operations plus AVR with either a sutureless valve (group 1, n=38) or a conventional bioprosthetic or mechanical valve (group 2, n=32). Baseline patient characteristics were similar except for worse New York Heart Association functional status and the prevalence of diabetes mellitus in group 1. In group 1, the operative, cross-clamp, and cardiopulmonary bypass times were shorter (all P=0.001), postoperative drainage amounts were lower (P=0.009), hospital stays were shorter (P=0.004), and less red blood cell transfusion was needed (P=0.037). Echocardiograms before patients' discharge from the hospital showed lower peak and mean aortic gradients in group 1 (mean transvalvular gradient, 8.4 ± 2.8 vs 12.2 ± 5.2 mmHg; P=0.012). We found that elderly, high-risk patients who underwent multiple cardiac surgical procedures and sutureless AVR had better hemodynamic outcomes and shorter ischemic times than did patients who underwent conventional AVR.
Collapse
|
15
|
Pacemaker Implantation Rate Post Sutureless Aortic Valve Replacement: 23% Is Just Too High. Ann Thorac Surg 2017; 104:1761-1762. [DOI: 10.1016/j.athoracsur.2016.12.050] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Accepted: 12/30/2016] [Indexed: 11/24/2022]
|
16
|
The Use of Rapid Deployment Valves in Combined Aortic and Mitral Valve Surgery: One-Year Clinical and Echocardiographic Outcomes. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2017; 12:201-206. [PMID: 28549026 DOI: 10.1097/imi.0000000000000373] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Patients undergoing multiple valve surgery represent a high-risk group who could potentially benefit from a reduction of cross-clamp and cardiopulmonary bypass times because prolonged bypass and cross-clamp times are considered independent risk factors for increased morbidity and mortality after cardiac surgery. METHODS Between July 2013 and November 2014, 16 patients underwent rapid deployment aortic valve replacement with the EDWARDS INTUITY valve system in the setting of concomitant mitral disease. Fifteen patients showed mitral regurgitation, whereas one patient had severe mitral stenosis. Fourteen patients received mitral valve repair and two patients received biological mitral valve replacement. Tricuspid valve repair was performed additionally in two patients. The mean ± SD age was 72.8 ± 8.4 years, and the mean ± SD logistic EuroSCORE II is 8.7% ± 3.4%. RESULTS Within a 30-day perioperative period, no patient was lost (n = 0). The mean ± SD follow-up time was 11 ± 2 months. At 1 year, the overall survival was 81% (n = 13). A mean ± SD transaortic gradient of 10.7 ± 2.3 mm Hg and a mean ± SD effective orifice area of 1.7 ± 0.3 cm were measured echocardiographically. No higher-grade paravalvular leak (aortic insufficiency > 1+) occurred. Eight patients (61%) had no residual mitral regurgitation, four patients (30%) showed trivial regurgitation (1/4), and one patient (7.3%) had moderate mitral regurgitation (2/4). No interference of the subannular stent frame with the reconstructed valve or the biological mitral prosthesis was seen. CONCLUSIONS Rapid deployment aortic valve replacement with the EDWARDS INTUITY valve system in combined aortic and mitral valve surgery can be performed safely with reproducible results. One-year follow-up data of this small series shows encouraging results potentially justifying the extension of the indication for rapid deployment valves to patients with concomitant mitral disease. Especially elderly patients undergoing multiple valve surgery may benefit from a reduction of cardiopulmonary bypass and myocardial ischemic times.
Collapse
|
17
|
Schlömicher M, Bechtel M, Taghiyev Z, Al-Jabery Y, Lukas Haldenwang P, Moustafine V, Thomas Strauch J. The Use of Rapid Deployment Valves in Combined Aortic and Mitral Valve Surgery. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2017. [DOI: 10.1177/155698451701200307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Markus Schlömicher
- From the Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Matthias Bechtel
- From the Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Zulfugar Taghiyev
- From the Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Yazan Al-Jabery
- From the Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Peter Lukas Haldenwang
- From the Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Vadim Moustafine
- From the Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| | - Justus Thomas Strauch
- From the Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
| |
Collapse
|
18
|
Kirmani BH, Jones SG, Malaisrie SC, Chung DA, Williams RJNN. Limited versus full sternotomy for aortic valve replacement. Cochrane Database Syst Rev 2017; 4:CD011793. [PMID: 28394022 PMCID: PMC6478148 DOI: 10.1002/14651858.cd011793.pub2] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Aortic valve disease is a common condition that is easily treatable with cardiac surgery. This is conventionally performed by opening the sternum longitudinally down the centre ("median sternotomy") and replacing the valve under cardiopulmonary bypass. Median sternotomy is generally well tolerated, but as less invasive options have become available, the efficacy of limited incisions has been called into question. In particular, the effects of reducing the visibility and surgical access has raised safety concerns with regards to the placement of cannulae, venting of the heart, epicardial wire placement, and de-airing of the heart at the end of the procedure. These difficulties may increase operating times, affecting outcome. The benefits of smaller incisions are thought to include decreased pain; improved respiratory mechanics; reductions in wound infections, bleeding, and need for transfusion; shorter intensive care stay; better cosmesis; and a quicker return to normal activity. OBJECTIVES To assess the effects of minimally invasive aortic valve replacement via a limited sternotomy versus conventional aortic valve replacement via median sternotomy in people with aortic valve disease requiring surgical replacement. SEARCH METHODS We performed searches of CENTRAL, MEDLINE, Embase, clinical trials registries, and manufacturers' websites from inception to July 2016, with no language limitations. We reviewed references of identified papers to identify any further studies of relevance. SELECTION CRITERIA Randomised controlled trials comparing aortic valve replacement via a median sternotomy versus aortic valve replacement via a limited sternotomy. We excluded trials that performed other minimally invasive incisions such as mini-thoracotomies, port access, trans-apical, trans-femoral or robotic procedures. Although some well-conducted prospective and retrospective case-control and cohort studies exist, these were not included in this review. DATA COLLECTION AND ANALYSIS Two review authors independently assessed trial papers to extract data, assess quality, and identify risk of bias. A third review author provided arbitration where required. The quality of evidence was determined using the GRADE methodology and results of patient-relevant outcomes were summarised in a 'Summary of findings' table. MAIN RESULTS The review included seven trials with 511 participants. These included adults from centres in Austria, Spain, Italy, Germany, France, and Egypt. We performed 12 comparisons investigating the effects of minimally invasive limited upper hemi-sternotomy on aortic valve replacement as compared to surgery performed via full median sternotomy.There was no evidence of any effect of upper hemi-sternotomy on mortality versus full median sternotomy (risk ratio (RR) 1.01, 95% confidence interval (CI) 0.36 to 2.82; participants = 511; studies = 7; moderate quality). There was no evidence of an increase in cardiopulmonary bypass time with aortic valve replacement performed via an upper hemi-sternotomy (mean difference (MD) 3.02 minutes, 95% CI -4.10 to 10.14; participants = 311; studies = 5; low quality). There was no evidence of an increase in aortic cross-clamp time (MD 0.95 minutes, 95% CI -3.45 to 5.35; participants = 391; studies = 6; low quality). None of the included studies reported major adverse cardiac and cerebrovascular events as a composite end point.There was no evidence of an effect on length of hospital stay through limited hemi-sternotomy (MD -1.31 days, 95% CI -2.63 to 0.01; participants = 297; studies = 5; I2 = 89%; very low quality). Postoperative blood loss was lower in the upper hemi-sternotomy group (MD -158.00 mL, 95% CI -303.24 to -12.76; participants = 297; studies = 5; moderate quality). The evidence did not support a reduction in deep sternal wound infections (RR 0.71, 95% CI 0.22 to 2.30; participants = 511; studies = 7; moderate quality) or re-exploration (RR 1.01, 95% CI 0.48 to 2.13; participants = 511; studies = 7; moderate quality). There was no change in pain scores by upper hemi-sternotomy (standardised mean difference (SMD) -0.33, 95% CI -0.85 to 0.20; participants = 197; studies = 3; I2 = 70%; very low quality), but there was a small increase in postoperative pulmonary function tests with minimally invasive limited sternotomy (MD 1.98 % predicted FEV1, 95% CI 0.62 to 3.33; participants = 257; studies = 4; I2 = 28%; low quality). There was a small reduction in length of intensive care unit stays as a result of the minimally invasive upper hemi-sternotomy (MD -0.57 days, 95% CI -0.93 to -0.20; participants = 297; studies = 5; low quality). Postoperative atrial fibrillation was not reduced with minimally invasive aortic valve replacement through limited compared to full sternotomy (RR 0.60, 95% CI 0.07 to 4.89; participants = 240; studies = 3; moderate quality), neither were postoperative ventilation times (MD -1.12 hours, 95% CI -3.43 to 1.19; participants = 297; studies = 5; low quality). None of the included studies reported cost analyses. AUTHORS' CONCLUSIONS The evidence in this review was assessed as generally low to moderate quality. The study sample sizes were small and underpowered to demonstrate differences in outcomes with low event rates. Clinical heterogeneity both between and within studies is a relatively fixed feature of surgical trials, and this also contributed to the need for caution in interpreting results.Considering these limitations, there was uncertainty of the effect on mortality or extracorporeal support times with upper hemi-sternotomy for aortic valve replacement compared to full median sternotomy. The evidence to support a reduction in total hospital length of stay or intensive care stay was low in quality. There was also uncertainty of any difference in the rates of other, secondary outcome measures or adverse events with minimally invasive limited sternotomy approaches to aortic valve replacement.There appears to be uncertainty between minimally invasive aortic valve replacement via upper hemi-sternotomy and conventional aortic valve replacement via a full median sternotomy. Before widespread adoption of the minimally invasive approach can be recommended, there is a need for a well-designed and adequately powered prospective randomised controlled trial. Such a study would benefit from performing a robust cost analysis. Growing patient preference for minimally invasive techniques merits thorough quality-of-life analyses to be included as end points, as well as quantitative measures of physiological reserve.
Collapse
Affiliation(s)
- Bilal H Kirmani
- Liverpool Heart and Chest HospitalCardiothoracic SurgeryThomas DriveLiverpoolMerseysideUKL14 3PE
| | - Sion G Jones
- Liverpool Heart and Chest HospitalCardiothoracic SurgeryThomas DriveLiverpoolMerseysideUKL14 3PE
| | - S C Malaisrie
- Northwestern UniversityDivision of Cardiac Surgery201 E. Huron StreetGalter 11‐140Chicago, ILUSA60611
| | - Darryl A Chung
- Liverpool Heart and Chest HospitalCardiothoracic SurgeryThomas DriveLiverpoolMerseysideUKL14 3PE
| | - Richard JNN Williams
- Liverpool Heart and Chest HospitalCardiothoracic SurgeryThomas DriveLiverpoolMerseysideUKL14 3PE
| | | |
Collapse
|
19
|
Conduction Disorders After Sutureless Aortic Valve Replacement. Ann Thorac Surg 2017; 103:1254-1260. [DOI: 10.1016/j.athoracsur.2016.07.044] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 07/11/2016] [Accepted: 07/15/2016] [Indexed: 11/23/2022]
|
20
|
Schäfer T, Doose C, Fujita B, Utzenrath M, Egron S, Schmitz C, Scholtz S, Kütting M, Hakim-Meibodi K, Börgermann J, Gummert J, Steinseifer U, Ensminger S. Preclinical determination of the best functional position for transcatheter heart valves implanted in rapid deployment bioprostheses. EUROINTERVENTION 2017; 12:1706-1714. [DOI: 10.4244/eij-d-16-00237] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
21
|
Minimally Invasive Versus Conventional Aortic Valve Replacement: A Propensity-Matched Study From the UK National Data. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2017; 11:15-23; discussion 23. [PMID: 26926521 PMCID: PMC4791314 DOI: 10.1097/imi.0000000000000236] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Minimally invasive aortic valve replacement (MIAVR) has been demonstrated as a safe and effective option but remains underused. We aimed to evaluate outcomes of isolated MIAVR compared with conventional aortic valve replacement (CAVR).
Collapse
|
22
|
Wang N, Tsai YC, Niles N, Tchantchaleishvili V, Di Eusanio M, Yan TD, Phan K. Transcatheter aortic valve implantation (TAVI) versus sutureless aortic valve replacement (SUAVR) for aortic stenosis: a systematic review and meta-analysis of matched studies. J Thorac Dis 2016; 8:3283-3293. [PMID: 28066608 DOI: 10.21037/jtd.2016.11.100] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
BACKGROUND With improving technologies and an increasingly elderly populations, there have been an increasing number of therapeutic options available for patients requiring aortic valve replacement. Recent evidence suggests that transcatheter aortic valve implantation (TAVI) is one suitable option for high risk inoperable patients, as well as high risk operable patients. Sutureless valve technology has also been developed concurrently, with facilitates surgical aortic valve replacement (SUAVR) by allow resection and replacement of the native aortic valve with minimal sutures and prosthesis anchoring required. For patients amenable for both TAVI and SUAVR, the evidence is unclear with regards to the benefits and risks of either approach. The objectives are to compare the perioperative outcomes and intermediate-term survival rates of TAVI and SUAVR in matched or propensity score matched studies. METHODS A systematic literature search was performed to include all matched or propensity score matched studies comparing SUAVR versus TAVI for severe aortic stenosis. A meta-analysis with odds ratios (OR) and mean differences were performed to compare key outcomes including paravalvular regurgitation and short and intermediate term mortality. RESULTS Six studies met our inclusion criteria giving a total of 741 patients in both the SUAVR and TAVI arm of the study. Compared to TAVI, SUAVR had a lower incidence of paravalvular leak (OR =0.06; 95% CI: 0.03-0.12, P<0.01). There was no difference in perioperative mortality, however SUAVR patients had significantly better survival rates at 1 (OR =2.40; 95% CI: 1.40-4.11, P<0.01) and 2 years (OR =4.62; 95% CI: 2.62-8.12, P<0.01). CONCLUSIONS The present study supports the use of minimally invasive SUAVR as an alternative to TAVI in high risk patients requiring aortic replacement. The presented results require further validation in prospective, randomized controlled studies.
Collapse
Affiliation(s)
- Nelson Wang
- Department of Medicine, University of Sydney, Sydney, Australia
| | - Yi-Chin Tsai
- The Collaborative Research (CORE) Group, Macquarie University, Sydney, Australia
| | - Natasha Niles
- The Collaborative Research (CORE) Group, Macquarie University, Sydney, Australia
| | | | - Marco Di Eusanio
- Cardiac Surgery Unit, Cardiovascular Department, 'G. Mazzini' Hospital Piazza Italia, Teramo, Italy
| | - Tristan D Yan
- The Collaborative Research (CORE) Group, Macquarie University, Sydney, Australia
| | - Kevin Phan
- Department of Medicine, University of Sydney, Sydney, Australia;; The Collaborative Research (CORE) Group, Macquarie University, Sydney, Australia
| |
Collapse
|
23
|
Landes U, Sagie A, Kornowski R. Transcatheter aortic valve implantation in degenerative sutureless perceval aortic bioprosthesis. Catheter Cardiovasc Interv 2016; 91:1000-1004. [PMID: 27696650 DOI: 10.1002/ccd.26576] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2015] [Accepted: 04/22/2016] [Indexed: 11/05/2022]
Abstract
Sutureless aortic bioprostheses (SAB) are increasingly being used to provide shorter cross-clamp time. Valve-in-valve transcatheter aortic valve replacement (VIV-A) is shown to be effective and safe in the vast majority of patients with degenerated bioprosthetics, yet its' use in SAB failure is infrequent. We present a case of balloon-expandable VIV-A in an 80-year-old woman who suffered severe symptomatic aortic regurgitation in a failed Perceval S 21-mm valve. Computed tomography scan demonstrated a deformed valve. Our heart team favored a percutaneous VIV-A over reoperation due to the patients' high surgical risk. An Edwards-Sapien XT 23 mm was successfully deployed with excellent results. The patient remained asymptomatic following 6 months. As other bioprosthesis, some sutureless valves are condemned to structural valve degeneration. Because VIV-A is being established for managing degenerative bioprosthesis in high risk patients, it is cardinal to identify its role in novel degenerative sutureless valves. SAB were introduced to the clinical market only 5-7 years ago. The absence of sutures may theoretically impose risk for valve instability when adding a transcatheter sutureless valve inside the first one. Our successful experience was very reassuring. We report its feasibility because we believe it should provide support for further investigation on VIV-A within novel SAV. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Uri Landes
- Department of Cardiology, Institute of Interventional Cardiology, Rabin Medical Center, Petach Tikva and Tel Aviv University, Tel Aviv, Israel
| | - Alexander Sagie
- Department of Cardiology, Institute of Interventional Cardiology, Rabin Medical Center, Petach Tikva and Tel Aviv University, Tel Aviv, Israel
| | - Ran Kornowski
- Department of Cardiology, Institute of Interventional Cardiology, Rabin Medical Center, Petach Tikva and Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
24
|
Tasca G, Vismara R, Mangini A, Romagnoni C, Contino M, Redaelli A, Fiore GB, Antona C. Comparison of the Performance of a Sutureless Bioprosthesis With Two Pericardial Stented Valves on Small Annuli: An In Vitro Study. Ann Thorac Surg 2016; 103:139-144. [PMID: 27544288 DOI: 10.1016/j.athoracsur.2016.05.089] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2016] [Revised: 03/21/2016] [Accepted: 05/23/2016] [Indexed: 11/18/2022]
Abstract
BACKGROUND Aortic valve replacement has evolved recently with the development of the sutureless bioprosthesis. One such valve is the Perceval bioprosthesis, which is built by mounting leaflets of bovine pericardium to a thin stent; this approach has the potential to provide an excellent fluid dynamic performance. We undertook an in vitro study to compare the hydrodynamic performance of the sutureless bioprosthesis with two standard pericardial stented bioprostheses (Crown and Magna). METHODS Tests were conducted using a mock loop, testing on two sizes of the three prostheses. The prosthesis sizes were chosen to house the valves in porcine aortic roots with a native annulus diameter of 19 mm (n = 6) or 21 mm (n = 6). The stroke volume ranged from 25 mL to 105 mL at a simulated heart rate of 70 beats per minute. RESULTS Mean pressure drop and energy loss rose with increasing stroke volume in all of the valves tested (p < 0.001), with the sutureless valve showing the lowest values for both variables (p < 0.001). Effective orifice area values were stable across the stroke volume intervals and were larger in the sutureless valves (p < 0.001). CONCLUSIONS All of the valves tested provided good fluid dynamic performances. The sutureless bioprosthesis provided the best performance with the least hindrance to flow behavior. From the hydrodynamic perspective, the sutureless prosthesis may present an advance in the evolution of bioprostheses, ensuring low gradients and potential for low incidence of patient-prosthesis mismatch even in small annuli.
Collapse
Affiliation(s)
- Giordano Tasca
- Cardiovascular Department, Cardiac Surgery Unit, Ospedale "A. Manzoni" di Lecco, Lecco; Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan.
| | - Riccardo Vismara
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan; FoRCardioLab, Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan
| | - Andrea Mangini
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan; FoRCardioLab, Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan; Cardiovascular Surgery Department, "L. Sacco" Hospital, Università degli Studi di Milano, Milan, Italy
| | - Claudia Romagnoni
- FoRCardioLab, Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan; Cardiovascular Surgery Department, "L. Sacco" Hospital, Università degli Studi di Milano, Milan, Italy
| | - Monica Contino
- FoRCardioLab, Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan; Cardiovascular Surgery Department, "L. Sacco" Hospital, Università degli Studi di Milano, Milan, Italy
| | - Alberto Redaelli
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan; FoRCardioLab, Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan
| | - Gianfranco Beniamino Fiore
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan; FoRCardioLab, Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan
| | - Carlo Antona
- FoRCardioLab, Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan; Cardiovascular Surgery Department, "L. Sacco" Hospital, Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
25
|
[Aortic valve replacement in the elderly]. Z Gerontol Geriatr 2016; 49:639-656. [PMID: 27518151 DOI: 10.1007/s00391-016-1112-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Revised: 05/27/2016] [Accepted: 06/29/2016] [Indexed: 11/27/2022]
Abstract
The treatment of severe symptomatic aortic valve stenosis by conventional aortic valve replacement (AVR) or by transcatheter aortic valve implantation (TAVI) has a good perinterventional prognosis even for patients of advanced age. Having a heart team select the best management strategies based on current guidelines for each individual patient is essential for success. Especially in elderly and increasingly multimorbid patients with sometimes severe preconditions, the detection of functional deficits is relevant not only for the mortality but also for perioperative and postoperative complications as well as the functional outcome. Various methods of geriatric assessment are important supplements to standard risk scores. The aim is to implement targeted interventions to minimize the risk factors and to improve the prognosis for elderly patients. The aim of this article is to provide an overview of the current therapy options for aortic valve replacement and to summarize current aspects of treatment options for elderly patients.
Collapse
|
26
|
Hanedan MO, Mataracı İ, Yürük MA, Özer T, Sayar U, Arslan AK, Ziyrek U, Yücel M. Early Outcomes of Sutureless Aortic Valves. THE KOREAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY 2016; 49:165-70. [PMID: 27298793 PMCID: PMC4900858 DOI: 10.5090/kjtcs.2016.49.3.165] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Revised: 02/06/2016] [Accepted: 02/12/2016] [Indexed: 12/04/2022]
Abstract
Background In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.
Collapse
Affiliation(s)
- Muhammet Onur Hanedan
- Department of Cardiovascular Surgery, Ahi Evren Thorax Cardiovascular Surgery Education and Research Hospital
| | - İlker Mataracı
- Department of Cardiovascular Surgery, Ahi Evren Thorax Cardiovascular Surgery Education and Research Hospital
| | - Mehmet Ali Yürük
- Department of Cardiovascular Surgery, Ahi Evren Thorax Cardiovascular Surgery Education and Research Hospital
| | - Tanıl Özer
- Department of Cardiovascular Surgery, Ahi Evren Thorax Cardiovascular Surgery Education and Research Hospital
| | - Ufuk Sayar
- Department of Cardiovascular Surgery, Ahi Evren Thorax Cardiovascular Surgery Education and Research Hospital
| | - Ali Kemal Arslan
- Department of Cardiovascular Surgery, Ahi Evren Thorax Cardiovascular Surgery Education and Research Hospital
| | - Uğur Ziyrek
- Department of Cardiovascular Surgery, Ahi Evren Thorax Cardiovascular Surgery Education and Research Hospital
| | - Murat Yücel
- Department of Cardiovascular Surgery, Ahi Evren Thorax Cardiovascular Surgery Education and Research Hospital
| |
Collapse
|
27
|
Forcillo J, Bouchard D, Nguyen A, Perrault L, Cartier R, Pellerin M, Demers P, Stevens LM, Carrier M. Perioperative outcomes with sutureless versus stented biological aortic valves in elderly persons. J Thorac Cardiovasc Surg 2016; 151:1629-36. [DOI: 10.1016/j.jtcvs.2015.12.056] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Revised: 12/07/2015] [Accepted: 12/29/2015] [Indexed: 10/22/2022]
|
28
|
Murzi M, Cerillo AG, Gilmanov D, Concistrè G, Farneti P, Glauber M, Solinas M. Exploring the learning curve for minimally invasive sutureless aortic valve replacement. J Thorac Cardiovasc Surg 2016; 152:1537-1546.e1. [PMID: 27262361 DOI: 10.1016/j.jtcvs.2016.04.094] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 03/29/2016] [Accepted: 04/28/2016] [Indexed: 01/13/2023]
Abstract
OBJECTIVE The study objective was to assess the learning process and quality of care of right minithoracotomy aortic valve replacement with a sutureless bioprosthesis at a single institution. METHODS We performed an analysis of the first 300 consecutive patients (aged 76 ± 6 years; logistic European System for Cardiac Operative Risk Evaluation 9 ± 6) who underwent sutureless valve implantation via a right minithoracotomy by 6 surgeons at the G. Pasquinucci Heart Hospital between 2011 and 2015. The learning curve was analyzed by dividing the study population into tertiles of 100 patients each. Departmental and individual learning curves were calculated using sequential probability cumulative sum failure analysis. Quality indicators were 2 composite end points reflecting the technical success and 30-day complications. RESULTS The overall mortality was 0.7% (2 patients). No significant differences were noted in terms of mortality and complications between tertiles. The sutureless valve was implanted successfully in 99% of patients (298/300). Cumulative sum analysis failed to identify any significant learning effects for technical success. Nevertheless, surgeons A, B, and C had a small initial learning curve, and surgeons D, E, and F did not, reflecting a trend toward a positive effect of cumulative institutional experience on the individual learning curve. The 30-day complications analysis revealed a cluster of failures at the beginning of the experience. This cluster prompted an internal audit and modification of the patients' selection process. Consecutively, the procedure returned in control. CONCLUSIONS Right minithoracotomy sutureless valve implantation can be performed safely without learning curve effects. Cumulative sum analysis is a valuable tool to describe and monitor the learning process. The analysis can identify periods of less than expected performance and alert the team to react.
Collapse
Affiliation(s)
- Michele Murzi
- Fondazione Toscana Gabriele Monasterio, G. Pasquinucci Heart Hospital, Massa, Italy.
| | | | - Danyar Gilmanov
- Fondazione Toscana Gabriele Monasterio, G. Pasquinucci Heart Hospital, Massa, Italy
| | - Giovanni Concistrè
- Fondazione Toscana Gabriele Monasterio, G. Pasquinucci Heart Hospital, Massa, Italy
| | - Pierandrea Farneti
- Fondazione Toscana Gabriele Monasterio, G. Pasquinucci Heart Hospital, Massa, Italy
| | - Mattia Glauber
- Fondazione Toscana Gabriele Monasterio, G. Pasquinucci Heart Hospital, Massa, Italy
| | - Marco Solinas
- Fondazione Toscana Gabriele Monasterio, G. Pasquinucci Heart Hospital, Massa, Italy
| |
Collapse
|
29
|
Fischlein T, Meuris B, Hakim-Meibodi K, Misfeld M, Carrel T, Zembala M, Gaggianesi S, Madonna F, Laborde F, Asch F, Haverich A. The sutureless aortic valve at 1 year: A large multicenter cohort study. J Thorac Cardiovasc Surg 2016; 151:1617-1626.e4. [PMID: 26936009 DOI: 10.1016/j.jtcvs.2015.12.064] [Citation(s) in RCA: 75] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 12/17/2015] [Accepted: 12/29/2015] [Indexed: 12/30/2022]
Abstract
OBJECTIVE Sutureless aortic valve replacement (AVR) offers an alternative to standard AVR in aortic stenosis. This prospective, single-arm study aimed to demonstrate safety and effectiveness of a bovine pericardial sutureless aortic valve at 1 year. METHODS From February 2010 to September 2013, 658 patients (mean age 78.3 ± 5.6 years; 40.0% octogenarian; 64.4% female; mean Society of Thoracic Surgeons score 7.2 ± 7.4) underwent sutureless AVR in 25 European centers. Concomitant cardiac procedures were performed in 29.5% and minimally invasive cardiac surgery in 33.3%. RESULTS One-year site-reported event rates were 8.1% for all-cause mortality, 4.5% for cardiac mortality, 3.0% for stroke, 1.9% for valve-related reoperation, 1.4% for endocarditis, and 0.6% for major paravalvular leak. No valve thrombosis, migration, or structural valve deterioration occurred. New York Heart Association class improved at least 1 level in 77.5% and remained stable (70.4% New York Heart Association class I or II at 1 year). Mean effective orifice area was 1.5 ± 0.4 cm(2); pressure gradient was 9.2 ± 5.0 mm Hg. Left ventricular mass decreased from 138.5 g/m(2) before surgery to 115.3 g/m(2) at 1 year (P < .001). Echocardiographic core laboratory findings confirmed that paravalvular leak was rare and remained stable during follow-up. CONCLUSIONS The Perceval sutureless valve resulted in low 1-year event rates in intermediate-risk patients undergoing AVR. New York Heart Association class improved in more than three-quarters of patients and remained stable. These data support the safety and efficacy to 1 year of the Perceval sutureless valve in this intermediate-risk population.
Collapse
Affiliation(s)
- Theodor Fischlein
- Department of Cardiac Surgery, Paracelsus Medical University, Klinikum Nürnberg, Nuremberg, Germany.
| | - Bart Meuris
- Department of Cardiac Surgery, U.Z. Gasthuisberg, Leuven, Belgium
| | - Kavous Hakim-Meibodi
- Department of Thoracic and Cardiovascular Surgery, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Martin Misfeld
- Klinik fur Herzchirurgie, Herzzentrum Universitaet Leipzig, Leipzig, Germany
| | | | - Marian Zembala
- Department of Cardiac, Vascular and Endovascular Surgery and Transplantology, School of Medicine, Silesian Center for Heart Diseases, Zabrze, Poland
| | - Sara Gaggianesi
- Clinical Affairs Department, Sorin Group Italia Srl, Saluggia, Italy
| | | | - François Laborde
- Cardiac Medico-Surgical Department, Institute Mutualiste Montsouris, Paris, France
| | - Federico Asch
- MedStar Cardiovascular Research Network, Washington Hospital Center, Washington, DC
| | - Axel Haverich
- Department of Cardiothoracic, Transplantation & Vascular Surgery, Hannover Medical School, Germany
| | | |
Collapse
|
30
|
Attia RQ, Hickey GL, Grant SW, Bridgewater B, Roxburgh JC, Kumar P, Ridley P, Bhabra M, Millner RWJ, Athanasiou T, Casula R, Chukwuemka A, Pillay T, Young CP. Minimally Invasive versus Conventional Aortic Valve Replacement: A Propensity-Matched Study from the UK National Data. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2016. [DOI: 10.1177/155698451601100104] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Rizwan Q. Attia
- Department of Cardiothoracic Surgery, Guy's and St Thomas’ Hospital, London, UK
| | - Graeme L. Hickey
- Centre for Health Informatics, Manchester Academic Health Science Centre, University of Manchester, Manchester, UK
- National Institute for Cardiovascular Outcomes Research, Institute of Cardiovascular Science, University College London, London, UK
| | - Stuart W. Grant
- Centre for Health Informatics, Manchester Academic Health Science Centre, University of Manchester, Manchester, UK
- Department of Cardiothoracic Surgery, Manchester Academic Health Science Centre, University Hospital of South Manchester, Wythenshawe, UK
| | - Ben Bridgewater
- Centre for Health Informatics, Manchester Academic Health Science Centre, University of Manchester, Manchester, UK
- National Institute for Cardiovascular Outcomes Research, Institute of Cardiovascular Science, University College London, London, UK
- Department of Cardiothoracic Surgery, Manchester Academic Health Science Centre, University Hospital of South Manchester, Wythenshawe, UK
| | - James C. Roxburgh
- Department of Cardiothoracic Surgery, Guy's and St Thomas’ Hospital, London, UK
| | - Pankaj Kumar
- Department of Cardiothoracic Surgery, Morriston Hospital, Morriston, Swansea, UK
| | - Paul Ridley
- Department of Cardiothoracic Surgery North Staffordshire Royal Infirmary, University Hospital of North Staffordshire NHS Trust, Stoke-on-Trent, UK
| | - Moninder Bhabra
- Department of Cardiothoracic Surgery, Heart and Lung Centre, New Cross Hospital, Wolverhampton, UK
| | - Russell W. J. Millner
- Department of Cardiothoracic Surgery, Lancashire Cardiac Centre, Victoria Hospital NHS Trust, Blackpool, UK
| | - Thanos Athanasiou
- Department of Cardiothoracic Surgery, Hammersmith Hospital, London, UK
| | - Roberto Casula
- Department of Cardiothoracic Surgery, Hammersmith Hospital, London, UK
| | - Andrew Chukwuemka
- Department of Cardiothoracic Surgery, Hammersmith Hospital, London, UK
| | - Thasee Pillay
- Department of Cardiothoracic Surgery, The Cardiothoracic Centre, Freeman Hospital, Newcastle upon Tyne, UK
| | | |
Collapse
|
31
|
Gersak B, Fischlein T, Folliguet TA, Meuris B, Teoh KH, Moten SC, Solinas M, Miceli A, Oberwalder PJ, Rambaldini M, Bhatnagar G, Borger MA, Bouchard D, Bouchot O, Clark SC, Dapunt OE, Ferrarini M, Laufer G, Mignosa C, Millner R, Noirhomme P, Pfeiffer S, Ruyra-Baliarda X, Shrestha M, Suri RM, Troise G, Diegeler A, Laborde F, Laskar M, Najm HK, Glauber M. Sutureless, rapid deployment valves and stented bioprosthesis in aortic valve replacement: recommendations of an International Expert Consensus Panel. Eur J Cardiothorac Surg 2015; 49:709-18. [DOI: 10.1093/ejcts/ezv369] [Citation(s) in RCA: 90] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2015] [Accepted: 09/22/2015] [Indexed: 01/28/2023] Open
|
32
|
Borger MA, Dohmen P, Misfeld M, Mohr FW. Minimal invasive implantation of an EDWARDS INTUITY rapid deployment aortic valve. Multimed Man Cardiothorac Surg 2015; 2013:mmt011. [PMID: 24413009 DOI: 10.1093/mmcts/mmt011] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
The development of rapid deployment and sutureless aortic valves represents a translation of knowledge gained from the performance of transcutaneous aortic valve replacement (AVR) procedures combined with decades of experience of conventional AVR surgery. Such devices have gained increasing clinical acceptance-particularly in Europe-with almost 3000 total implants to date. Rapid deployment and sutureless valves facilitate minimal invasive AVR and are associated with significantly reduced myocardial ischaemic and cardiopulmonary bypass times. The reduced ischaemic times may also be important for patients requiring complex combined procedures, or those with poor left ventricular function. These devices are associated with excellent haemodynamic performance and acceptable rates of pacemaker implantation and paravalvular leak. The current case involves a minimal invasive implantation of an EDWARDS INTUITY rapid deployment valve (Edwards Lifesciences, Irvine, CA, USA).
Collapse
Affiliation(s)
- Michael A Borger
- Department of Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany
| | | | | | | |
Collapse
|
33
|
Laborde F, Fischlein T, Hakim-Meibodi K, Misfeld M, Carrel T, Zembala M, Madonna F, Meuris B, Haverich A, Shrestha M. Clinical and haemodynamic outcomes in 658 patients receiving the Perceval sutureless aortic valve: early results from a prospective European multicentre study (the Cavalier Trial)†. Eur J Cardiothorac Surg 2015; 49:978-86. [PMID: 26245628 DOI: 10.1093/ejcts/ezv257] [Citation(s) in RCA: 97] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2015] [Accepted: 06/18/2015] [Indexed: 01/22/2023] Open
Abstract
OBJECTIVES The aim of the Cavalier trial was to evaluate the safety and performance of the Perceval sutureless aortic valve in patients undergoing aortic valve replacement (AVR). We report the 30-day clinical and haemodynamic outcomes from the largest study cohort with a sutureless valve. METHODS From February 2010 to September 2013, 658 consecutive patients (mean age 77.8 years; 64.4% females; mean logistic EuroSCORE 10.2%) underwent AVR in 25 European Centres. Isolated AVRs were performed in 451 (68.5%) patients with a less invasive approach in 219 (33.3%) cases. Of the total, 40.0% were octogenarians. Congenital bicuspid aortic valve was considered an exclusion criterion. RESULTS Implantation was successful in 628 patients (95.4%). In isolated AVR through sternotomy, the mean cross-clamp time and the cardiopulmonary bypass (CPB) time were 32.6 and 53.7 min, and with the less invasive approach 38.8 and 64.5 min, respectively. The 30-day overall and valve-related mortality rates were 3.7 and 0.5%, respectively. Valve explants, stroke and endocarditis occurred in 0.6, 2.1 and in 0.1% of cases, respectively. Preoperative mean and peak pressure gradients decreased from 44.8 and 73.24 mmHg to 10.24 and 19.27 mmHg at discharge, respectively. The mean effective orifice area improved from 0.72 to 1.46 cm(2). CONCLUSIONS The current 30-day results show that the Perceval valve is safe (favourable haemodynamic effect and low complication rate), and can be implanted with a fast and reproducible technique after a short learning period. Short cross-clamp and CPB times were achieved in both isolated and combined procedures. The Perceval valve represents a promising alternative to biological AVR, especially with a less invasive approach and in older patients.
Collapse
Affiliation(s)
- François Laborde
- Cardiac Medico-Surgical Department, Institute Mutualiste Montsouris, Paris, France
| | - Theodor Fischlein
- Department of Cardiac Surgery, Klinikum Nuernberg, Paracelsus Medical University, Nuremberg, Germany
| | | | - Martin Misfeld
- Herzzentrum Universitaet Leipzig, Klinik fur Herzchirurgie, Leipzig, Germany
| | | | - Marian Zembala
- Silesian University Center for Heart Disease, Zabrze, Poland
| | | | - Bart Meuris
- Department of Cardiac Surgery, U.Z. Gasthuisberg, Leuven, Belgium
| | - Axel Haverich
- Department of Cardio-thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Malakh Shrestha
- Department of Cardio-thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | | |
Collapse
|
34
|
Glauber M, Miceli A. Encouraging durability results for sutureless aortic valve: The new gold standard for aortic valve replacement? J Thorac Cardiovasc Surg 2015; 150:88-90. [DOI: 10.1016/j.jtcvs.2015.04.047] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Accepted: 04/17/2015] [Indexed: 01/28/2023]
|
35
|
Left ventricular mass regression after two alternative sutureless aortic bioprostheses. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2015; 10:114-9. [PMID: 25803774 DOI: 10.1097/imi.0000000000000138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Left ventricular (LV) hypertrophy in aortic stenosis (AS) constitutes a risk factor for cardiac morbidity and mortality. The aim of this study was to investigate the degree of LV mass regression after aortic valve replacement (AVR) with two alternative sutureless self-expanding strategies: Perceval S (Sorin Group, Saluggia, Italy) (P) and 3f Enable (Medtronic, ATS Medical, Minneapolis, MN USA) (E) aortic bioprostheses. METHODS Between March 2010 and December 2011, 129 patients with symptomatic AS underwent AVR with the Perceval S or 3f Enable bioprostheses in two cardiac surgery departments (Massa, Italy; Nuremberg, Germany). We analyzed 45 patients in group P and 19 in group E undergoing isolated AVR with a 6-month follow-up. The LV mass was calculated using the Devereux formula and was indexed to body surface area. RESULTS Baseline patient characteristics showed no significant differences between the two groups. There were no in-hospital deaths. Two patients in group P died at follow-up versus zero in group E (P = 0.49). Mean LV mass index decreased from 146.6 (78) g/m at baseline to 123.3 (63) g/m at follow-up (P < 0.001) in group P and from 146.1 (47.6) g/m to 118.1 (39.8) g/m (P = 0.003) in group E, with no significant difference between the two groups (P = 0.315). This effect was accompanied by significant clinical improvement. CONCLUSIONS In isolated AS, AVR with sutureless bioprostheses is associated with a significant regression in LV mass at 6-month follow-up. No significant differences were present between the two alternative sutureless strategies. However, regression needs an evaluation with long-term echocardiographic examinations.
Collapse
|
36
|
Gilmanov DS, Solinas M, Kallushi E, Gasbarri T, Bianchi G, Farneti PA, Glauber M. Sutureless aortic valve replacement for aortic incompetence. J Card Surg 2015; 30:391-5. [PMID: 25765903 DOI: 10.1111/jocs.12531] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
OBJECTIVE Sutureless prostheses for surgical aortic valve replacement (AVR) are usually used in degenerative calcified aortic stenosis. Less is known on the application of sutureless prostheses for pure aortic incompetence. METHODS Between 2011 and 2014, 442 patients were operated on with the Perceval aortic sutureless valve implant. We identified 11 patients (10 female, mean age 70.5) who underwent sutureless AVR for pure aortic incompetence (off-label use). Three patients had a left ventricle ejection fraction of 30% or less. Mean logistic EuroSCORE was 15.2 (range 2.2-45.2). In five patients associated mitral procedures (three [60%] repair and two [40%] replacement) were performed. Four procedures were performed through a minimally invasive approach (three right minithoracotomies and one partial sternotomy). RESULTS Mean cardiopulmonary bypass time was 130.2 min and aortic cross clamp time was 82.2 min. Mean implanted prosthesis size was 24.5 ± 1.3 (median 25) mm (insignificant correlation with preoperative aortic valve annulus measurement by transthoracic echocardiography: 21.6 ± 1.5 [median 21] mm, Pearson's r = 0.373, p = 0.259). One patient died on 24th day after AVR associated with aortic arch replacement and hypothermic circulatory arrest (10 years after correction for type A aortic dissection). No residual para- or intravalvular leakage was present on discharge and 12-month follow-up. No migration of the prosthesis occurred. CONCLUSION Sutureless AVR is an option in selected patients with aortic incompetence. Preoperative aortic annulus measurement by echocardiography has poor predictive value for estimation of prosthetic valve size.
Collapse
Affiliation(s)
- Daniyar Sh Gilmanov
- Adult Cardiac Surgery Department, G. Monasterio Tuscany Foundation - G. Pasquinucci Heart Hospital, Massa, Italy
| | | | | | | | | | | | | |
Collapse
|
37
|
Shrestha M, Fischlein T, Meuris B, Flameng W, Carrel T, Madonna F, Misfeld M, Folliguet T, Haverich A, Laborde F. European multicentre experience with the sutureless Perceval valve: clinical and haemodynamic outcomes up to 5 years in over 700 patients. Eur J Cardiothorac Surg 2015; 49:234-41. [DOI: 10.1093/ejcts/ezv040] [Citation(s) in RCA: 113] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2014] [Accepted: 01/15/2015] [Indexed: 11/13/2022] Open
|
38
|
Concistrè G, Chiaramonti F, Santarpino G, Pfeiffer S, Marchi F, Vogt F, Miceli A, Glauber M, Fischlein T, Solinas M. Left Ventricular Mass Regression after Two Alternative Sutureless Aortic Bioprostheses. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2015. [DOI: 10.1177/155698451501000207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Giovanni Concistrè
- Department of Cardiac Surgery, Ospedale del Cuore “G. Pasquinucci” – Fondazione Monasterio-CNR, Massa, Italy
| | - Francesca Chiaramonti
- Department of Cardiac Surgery, Ospedale del Cuore “G. Pasquinucci” – Fondazione Monasterio-CNR, Massa, Italy
| | - Giuseppe Santarpino
- Department of Cardiac Surgery, Cardiovascular Center - Paracelsus Medical University, Nuremberg, Germany
| | - Steffen Pfeiffer
- Department of Cardiac Surgery, Cardiovascular Center - Paracelsus Medical University, Nuremberg, Germany
| | - Federica Marchi
- Department of Cardiac Surgery, Ospedale del Cuore “G. Pasquinucci” – Fondazione Monasterio-CNR, Massa, Italy
| | - Ferdinand Vogt
- Department of Cardiac Surgery, Cardiovascular Center - Paracelsus Medical University, Nuremberg, Germany
| | - Antonio Miceli
- Department of Cardiac Surgery, Ospedale del Cuore “G. Pasquinucci” – Fondazione Monasterio-CNR, Massa, Italy
| | - Mattia Glauber
- Department of Cardiac Surgery, Ospedale del Cuore “G. Pasquinucci” – Fondazione Monasterio-CNR, Massa, Italy
| | - Theodor Fischlein
- Department of Cardiac Surgery, Cardiovascular Center - Paracelsus Medical University, Nuremberg, Germany
| | - Marco Solinas
- Department of Cardiac Surgery, Ospedale del Cuore “G. Pasquinucci” – Fondazione Monasterio-CNR, Massa, Italy
| |
Collapse
|
39
|
Schlömicher M, Haldenwang PL, Moustafine V, Bechtel M, Strauch JT. Minimal access rapid deployment aortic valve replacement: Initial single-center experience and 12-month outcomes. J Thorac Cardiovasc Surg 2015; 149:434-40. [DOI: 10.1016/j.jtcvs.2014.09.118] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2014] [Revised: 09/07/2014] [Accepted: 09/27/2014] [Indexed: 01/21/2023]
|
40
|
Byrom MJ, Sivakumaran Y, Vallely MP, Wilson MK, Bannon PG. How many sutures should a sutureless valve need? J Thorac Cardiovasc Surg 2015; 149:1058-9. [PMID: 25626952 DOI: 10.1016/j.jtcvs.2014.12.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2014] [Accepted: 12/22/2014] [Indexed: 10/24/2022]
Affiliation(s)
- Michael John Byrom
- Institute of Academic Surgery, Royal Prince Alfred Hospital, Sydney, Australia; The Baird Institute, Sydney, Australia
| | | | - Michael Patrick Vallely
- Institute of Academic Surgery, Royal Prince Alfred Hospital, Sydney, Australia; The Baird Institute, Sydney, Australia
| | - Michael Keith Wilson
- Institute of Academic Surgery, Royal Prince Alfred Hospital, Sydney, Australia; The Baird Institute, Sydney, Australia
| | - Paul Gerard Bannon
- Institute of Academic Surgery, Royal Prince Alfred Hospital, Sydney, Australia; The Baird Institute, Sydney, Australia; University of Sydney, Sydney, Australia.
| |
Collapse
|
41
|
Sutureless Aortic Valve Replacement: A Canadian Multicentre Study. Can J Cardiol 2015; 31:63-8. [DOI: 10.1016/j.cjca.2014.10.030] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 10/27/2014] [Accepted: 10/28/2014] [Indexed: 11/19/2022] Open
|
42
|
Miceli A, Santarpino G, Pfeiffer S, Murzi M, Gilmanov D, Concistré G, Quaini E, Solinas M, Fischlein T, Glauber M. Minimally invasive aortic valve replacement with Perceval S sutureless valve: Early outcomes and one-year survival from two European centers. J Thorac Cardiovasc Surg 2014; 148:2838-43. [DOI: 10.1016/j.jtcvs.2014.02.085] [Citation(s) in RCA: 103] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Revised: 02/06/2014] [Accepted: 02/28/2014] [Indexed: 11/25/2022]
|
43
|
Aortic Valve Replacement Through Right Anterior Minithoracotomy: Can Sutureless Technology Improve Clinical Outcomes? Ann Thorac Surg 2014; 98:1585-92. [DOI: 10.1016/j.athoracsur.2014.05.092] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2014] [Revised: 05/26/2014] [Accepted: 05/29/2014] [Indexed: 11/18/2022]
|
44
|
Biancari F, Martin M, Bordin G, Vettore E, Vinco G, Anttila V, Airaksinen J, Vasques F. Basic Data From 176 Studies on the Immediate Outcome After Aortic Valve Replacement With or Without Coronary Artery Bypass Surgery. J Cardiothorac Vasc Anesth 2014; 28:1251-6. [DOI: 10.1053/j.jvca.2013.07.020] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2013] [Indexed: 11/11/2022]
|
45
|
Pollari F, Santarpino G, Dell'Aquila AM, Gazdag L, Alnahas H, Vogt F, Pfeiffer S, Fischlein T. Better Short-Term Outcome by Using Sutureless Valves: A Propensity-Matched Score Analysis. Ann Thorac Surg 2014; 98:611-6; discussion 616-7. [DOI: 10.1016/j.athoracsur.2014.04.072] [Citation(s) in RCA: 91] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2014] [Revised: 04/08/2014] [Accepted: 04/10/2014] [Indexed: 11/28/2022]
|
46
|
Wollersheim LW, Li WW, de Mol BA. Current status of surgical treatment for aortic valve stenosis. J Card Surg 2014; 29:630-7. [PMID: 24980691 DOI: 10.1111/jocs.12384] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
In this review, we discuss the current surgical treatment for aortic valve stenosis. Surgical strategy for treatment of aortic valve stenosis is based on the risk profile of the patient. We reviewed the existing literature and present the current state of the art of these various approaches, taking into account clinical outcomes, quality of life, costs, and learning curve.
Collapse
Affiliation(s)
- Laurens W Wollersheim
- Department of Cardiothoracic Surgery, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | | | | |
Collapse
|
47
|
Two alternative sutureless strategies for aortic valve replacement: a two-center experience. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2014; 8:253-7. [PMID: 24145969 DOI: 10.1097/imi.0000000000000007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Important comorbid conditions in patients referred for aortic valve replacement (AVR) require less invasive strategies. We describe our initial experience with the Perceval S (Sorin Group, Saluggia, Italy) and 3f Enable (Medtronic, Minneapolis, MN USA) sutureless aortic bioprostheses. METHODS We compared intraoperative data, postoperative clinical outcomes, and echocardiographic results from patients receiving a Perceval S (P group; n = 97) or a 3f Enable (E group; n = 32) prosthesis in two cardiac surgery departments (Nuremberg, Germany, and Massa, Italy). RESULTS Baseline patient characteristics were similar in both groups, except for mean ± SD body surface area (P group = 2.01 ± 2.9 m, E group = 1.83 ± 3.8 m; P < 0.001). Sixty-five patients (67%) in the P group and 19 patients (59.5%) in the E group (P = 0.22) underwent minimally invasive AVR with either ministernotomy or right anterior minithoracotomy approach. Concomitant procedures were performed in 37 patients (38%) in the P group and 9 patients (28%) in the E group (P = 0.56). In-hospital mortality was 2%. The mean ± SD prosthesis diameter was 23.5 ± 1.4 mm (P group) compared with 22.1 ± 2 mm (E group) (P < 0.001). In isolated AVR, aortic cross-clamp time was 36 ± 12.7 minutes in the P group and 66 ± 18 minutes in the E group (P < 0.001). At a mean ± SD follow-up of 8.3 ± 4.5 months, survival was 97% (one death in the P group). In five patients (P group = 1, E group = 4), a moderate paravalvular leak was present (P = 0.013). The mean ± SD transvalvular gradient was 9.1 ± 3.3 mm Hg with the Perceval S and 11.2 ± 5.2 mm Hg with the 3f Enable (P = 0.017). CONCLUSIONS Aortic valve replacement with sutureless aortic bioprosthesis is feasible, also with a minimally invasive approach. The Perceval S showed lower operative times and moderate paravalvular leaks and lower mean transvalvular gradients than did the 3f Enable, related to the larger diameter of the Perceval S implanted. Both prostheses showed an excellent hemodynamic performance. This new technology needs long-term follow-up.
Collapse
|
48
|
Santarpino G, Pfeiffer S, Sirch J, Vogt F, Concistrè G, Fischlein T. Minimally invasive aortic valve replacement with Perceval valves. J Cardiovasc Med (Hagerstown) 2014; 15:230-4. [DOI: 10.2459/jcm.0b013e328360936a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
49
|
Santarpino G, Pfeiffer S, Jessl J, Dell’Aquila AM, Pollari F, Pauschinger M, Fischlein T. Sutureless replacement versus transcatheter valve implantation in aortic valve stenosis: A propensity-matched analysis of 2 strategies in high-risk patients. J Thorac Cardiovasc Surg 2014; 147:561-7. [DOI: 10.1016/j.jtcvs.2013.10.025] [Citation(s) in RCA: 88] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Revised: 08/18/2013] [Accepted: 10/12/2013] [Indexed: 10/26/2022]
|
50
|
Borger MA, Dohmen P, Misfeld M, Mohr FW. Current trends in aortic valve replacement: development of the rapid deployment EDWARDS INTUITY valve system. Expert Rev Med Devices 2014; 10:461-70. [DOI: 10.1586/17434440.2013.811828] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|