1
|
Sharma A, Chhabra M. The versatility of microbial fuel cells as tools for organic matter monitoring. BIORESOURCE TECHNOLOGY 2023; 377:128949. [PMID: 36963695 DOI: 10.1016/j.biortech.2023.128949] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/17/2023] [Accepted: 03/20/2023] [Indexed: 06/18/2023]
Abstract
Water monitoring and remediation require robust, low-cost, and reliable test systems that can couple with prompt treatment interventions. Organic matter (BOD, COD), toxicants, heavy metals, and other pollutants in water need to be regularly inspected. Microbial fuel cells (MFCs) have already gained popularity as BOD biomonitoring systems as these don't need an external transducer or power source. Moreover, these systems are cost-effective, compact, biodegradable, reusable, portable, and applicable for on-site measurements. MFCs truly stands out as online BOD measurement devices as they provide wide detection range (0-25 g/L), low response time (2-4 min) and longer stability in continuous operations (2-5 years) in a cost-effective approach. This review examines the benefits, kinds, performance metrics, and signal optimization of the current state-of-the-art of the BOD measurement, with detailed focus on MFC-based BOD biomonitoring systems. This review covers the important technological breakthroughs in practical applications with associated bottlenecks to develop reliable sensing systems.
Collapse
Affiliation(s)
- Arti Sharma
- Environmental Biotechnology Laboratory, Department of Bioscience and Bioengineering, Indian Institute of Technology Jodhpur (IIT J), Jodhpur 342030, Rajasthan, India
| | - Meenu Chhabra
- Environmental Biotechnology Laboratory, Department of Bioscience and Bioengineering, Indian Institute of Technology Jodhpur (IIT J), Jodhpur 342030, Rajasthan, India.
| |
Collapse
|
2
|
Aguilar-Torrejón JA, Balderas-Hernández P, Roa-Morales G, Barrera-Díaz CE, Rodríguez-Torres I, Torres-Blancas T. Relationship, importance, and development of analytical techniques: COD, BOD, and, TOC in water—An overview through time. SN APPLIED SCIENCES 2023. [DOI: 10.1007/s42452-023-05318-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023] Open
Abstract
AbstractAnalytical techniques to measure organic matter in water, such as Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD5), and Total Organic Carbon (TOC) are widely used. Modifications have been proposed to make them faster, more sensitive, and more environmentally friendly. The purpose of producing a review over some time is to show the changes made on the standardized methods of each of these techniques, and to highlight the relationship between them in the process of ascertaining organic matter in water. Modifications to techniques COD and BOD entail several factors that need to be considered, namely: time, miniaturization, sensitivity, use of environmentally friendly reagents. Changes to TOC are focused on detection systems. Despite the advantages obtained by the modified techniques, traditional methods continue to be widely used, in most cases due to the lack of standardization of the new methods.
Graphic Abstract
Collapse
|
3
|
Wang C, Yin L, Wang S, Jin X, Yang J, Liu H. Role played by the physical structure of carbon anode materials in MFC biosensor for BOD measurement. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 856:158848. [PMID: 36122718 DOI: 10.1016/j.scitotenv.2022.158848] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 09/14/2022] [Accepted: 09/14/2022] [Indexed: 06/15/2023]
Abstract
Microbial fuel cell (MFC) has been extensively studied as a biosensor for determining biochemical oxygen demand (BOD). The method for quantifying BOD by employing coulombic yield (Q) of a bio-electrochemical degradation process obtained from MFC biosensors is referred to as BODQ. The physical structures of anode materials greatly affect the sensitivity and accuracy of the biosensor. In this work, the effects of carbon cloth (CC) and carbon felt (CF) as anode substrate materials on the BODQ determination efficiencies were studied. The CF-MFC biosensor showed higher BODQ response than that of the CC-MFC within 25-400 mg L-1 BOD concentration range, and the test value was very close to the theoretical BOD. The difference is resulting from higher coulombic efficiency (CE) of CF-MFC (64.89-65.38 %) than CC-MFC (55.58-63.51 %). It should be noted that for water samples with low BOD concentrations the physical structures of anode materials play a leading role in CE. For synthetic wastewaters with 25 mg L-1 BOD, the CE of CF-MFC (65.38 %) was 17.63 % higher than that of CC-MFC (55.58 %). In contrast to the densely woven CC coated with thick biofilm, CF with loose carbon fiber and thin biofilm makes it good for organic diffusion and electron transportation, thus contributing to higher and more stable CE. These results indicate that the CF-MFC is more suitable for determining BODQ values over a wide concentration range. This work provides a useful strategy for selecting desirable MFC's anode material as the BOD biosensor. MFC biosensors with high-porosity biological anodes can obtain more accurate BOD test values.
Collapse
Affiliation(s)
- Chuan Wang
- Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Institute of Environmental Research at Greater Bay, Guangzhou University, Guangzhou 510006, China
| | - Lanyan Yin
- Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Institute of Environmental Research at Greater Bay, Guangzhou University, Guangzhou 510006, China
| | - Sha Wang
- Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
| | - Xiaojun Jin
- Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
| | - Jingxin Yang
- Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Institute of Environmental Research at Greater Bay, Guangzhou University, Guangzhou 510006, China.
| | - Hong Liu
- Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
| |
Collapse
|
4
|
Arlyapov VA, Plekhanova YV, Kamanina OA, Nakamura H, Reshetilov AN. Microbial Biosensors for Rapid Determination of Biochemical Oxygen Demand: Approaches, Tendencies and Development Prospects. BIOSENSORS 2022; 12:842. [PMID: 36290979 PMCID: PMC9599453 DOI: 10.3390/bios12100842] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 09/23/2022] [Accepted: 10/01/2022] [Indexed: 06/16/2023]
Abstract
One of the main indices of the quality of water is the biochemical oxygen demand (BOD). A little over 40 years have passed since the practical application of the first microbial sensor for the determination of BOD, presented by the Japanese professor Isao Karube. This time span has brought new knowledge to and practical developments in the use of a wide range of microbial cells based on BOD biosensors. At present, this field of biotechnology is becoming an independent discipline. The traditional BOD analysis (BOD5) has not changed over many years; it takes no less than 5 days to carry out. Microbial biosensors can be used as an alternative technique for assessing the BOD attract attention because they can reduce hundredfold the time required to measure it. The review examines the experience of the creation and practical application of BOD biosensors accumulated by the international community. Special attention is paid to the use of multiple cell immobilization methods, signal registration techniques, mediators and cell consortia contained in the bioreceptor. We consider the use of nanomaterials in the modification of analytical devices developed for BOD evaluation and discuss the prospects of developing new practically important biosensor models.
Collapse
Affiliation(s)
- Vyacheslav A. Arlyapov
- Laboratory of Biologically Active Compounds and Biocomposites, Federal State Budgetary Educational Establishment of Higher Education “Tula State University”, 300012 Tula, Russia
| | - Yulia V. Plekhanova
- Pushchino Center for Biological Research of the Russian Academy of Sciences, G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia
| | - Olga A. Kamanina
- Laboratory of Biologically Active Compounds and Biocomposites, Federal State Budgetary Educational Establishment of Higher Education “Tula State University”, 300012 Tula, Russia
| | - Hideaki Nakamura
- Department of Liberal Arts, Tokyo University of Technology, 1404-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| | - Anatoly N. Reshetilov
- Pushchino Center for Biological Research of the Russian Academy of Sciences, G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia
| |
Collapse
|
5
|
Hui Y, Huang Z, Alahi MEE, Nag A, Feng S, Mukhopadhyay SC. Recent Advancements in Electrochemical Biosensors for Monitoring the Water Quality. BIOSENSORS 2022; 12:bios12070551. [PMID: 35884353 PMCID: PMC9313366 DOI: 10.3390/bios12070551] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 07/10/2022] [Accepted: 07/13/2022] [Indexed: 05/06/2023]
Abstract
The release of chemicals and microorganisms from various sources, such as industry, agriculture, animal farming, wastewater treatment plants, and flooding, into water systems have caused water pollution in several parts of our world, endangering aquatic ecosystems and individual health. World Health Organization (WHO) has introduced strict standards for the maximum concentration limits for nutrients and chemicals in drinking water, surface water, and groundwater. It is crucial to have rapid, sensitive, and reliable analytical detection systems to monitor the pollution level regularly and meet the standard limit. Electrochemical biosensors are advantageous analytical devices or tools that convert a bio-signal by biorecognition elements into a significant electrical response. Thanks to the micro/nano fabrication techniques, electrochemical biosensors for sensitive, continuous, and real-time detection have attracted increasing attention among researchers and users worldwide. These devices take advantage of easy operation, portability, and rapid response. They can also be miniaturized, have a long-life span and a quick response time, and possess high sensitivity and selectivity and can be considered as portable biosensing assays. They are of special importance due to their great advantages such as affordability, simplicity, portability, and ability to detect at on-site. This review paper is concerned with the basic concepts of electrochemical biosensors and their applications in various water quality monitoring, such as inorganic chemicals, nutrients, microorganisms' pollution, and organic pollutants, especially for developing real-time/online detection systems. The basic concepts of electrochemical biosensors, different surface modification techniques, bio-recognition elements (BRE), detection methods, and specific real-time water quality monitoring applications are reviewed thoroughly in this article.
Collapse
Affiliation(s)
- Yun Hui
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China;
| | - Zhaoling Huang
- School of Mechanical and Electrical Engineering, Guilin University of Electronic Technology, Guilin 541004, China;
| | - Md Eshrat E. Alahi
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China;
- Correspondence: (M.E.E.A.); (S.F.)
| | - Anindya Nag
- Faculty of Electrical and Computer Engineering, Technische Universität Dresden, 01062 Dresden, Germany;
- Centre for Tactile Internet with Human-in-the-Loop (CeTI), Technische Universität Dresden, 01069 Dresden, Germany
| | - Shilun Feng
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
- Correspondence: (M.E.E.A.); (S.F.)
| | | |
Collapse
|
6
|
Study of an adsorption method for trace mercury based on Bacillus subtilis. OPEN CHEM 2021. [DOI: 10.1515/chem-2021-0099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Abstract
In order to decrease the difficulty in trace mercury determination, an adsorption method for trace mercury based on Bacillus subtilis cells was proposed in this article. The adsorption process was characterized by optical microscopy and SEM. The adsorption mechanism was analyzed by IR. The adsorption performance was studied by measuring the concentration of supernate and calculating the adsorption efficiency. When adsorbing Hg2+, Bacillus subtilis cells gathered and their structure turned coarse. The IR results illustrated that functional groups bound with Hg for complexation during adsorption. Bacillus subtilis completed adsorption for trace Hg2+ in 15 min. The adsorption efficiency was maintained above 80% under low Hg2+ concentrations (<200 µg/L). The proposed study illustrates that Bacillus subtilis cells are highly efficient and easily obtained material for the adsorption of trace mercury, which shows potential to be further used in the pretreatment of trace Hg2+ detection.
Collapse
|
7
|
Do MH, Ngo HH, Guo W, Chang SW, Nguyen DD, Deng L, Chen Z, Nguyen TV. Performance of mediator-less double chamber microbial fuel cell-based biosensor for measuring biological chemical oxygen. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2020; 276:111279. [PMID: 32891031 DOI: 10.1016/j.jenvman.2020.111279] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 08/18/2020] [Accepted: 08/19/2020] [Indexed: 06/11/2023]
Abstract
Recently, the microbial fuel cell-based biosensor has been considered as an attractive technology for measuring wastewater quality such as biochemical oxygen demand (BOD). In this study, a mediator-less double compartment MFC based biosensor utilizing carbon felt as an anode electrode and inoculated with mixed culture was developed to improve the real application of a rapid BOD detection. This study aims to: (i) establish the effect of the operating conditions (i.e., pH, external resistance, fuel feeding rate) on MFC performance; (ii) investigate the correlation between biochemical oxygen demand (BOD) and signal output, and (iii) evaluate the operational stability of the biosensor. The presented result reveals that the maximum current and power production was obtained while 100 mM NaCl and 50 mM Phosphate buffer saline was used as a catholyte solution, neutral pH condition of media and fuel feeding rate at 0.3 mL min-1. Notably, a wider range of BOD concentration up to 300 mg L -1 can be obtained with the voltage output (R2 > 0.9901). Stable and steady power was produced by running MFC in 30 days when cells operated at 1000 Ω external resistance. Our research has some competition with the previous double chamber MFC in the upper limit of BOD detection. This results might help to increase the real application of MFC based BOD biosensor in real-time measurement.
Collapse
Affiliation(s)
- Minh Hang Do
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, Sydney, NWS, 2007, Australia
| | - Huu Hao Ngo
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, Sydney, NWS, 2007, Australia; NTT Institute of Hi-Technology, Nguyen Tat Thanh University, Ho Chi Minh City, Viet Nam.
| | - Wenshan Guo
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, Sydney, NWS, 2007, Australia
| | - Soon Woong Chang
- Department of Environmental Energy Engineering, Kyonggi University, 442-760, Republic of Korea
| | - Dinh Duc Nguyen
- Department of Environmental Energy Engineering, Kyonggi University, 442-760, Republic of Korea; Institution of Research and Development, Duy Tan University, Da Nang, Viet Nam
| | - Lijuan Deng
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, Sydney, NWS, 2007, Australia
| | - Zhuo Chen
- School of Environment, Tsinghua University, Beijing, 100084, China
| | - Tien Vinh Nguyen
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, Sydney, NWS, 2007, Australia
| |
Collapse
|
8
|
Registration of BOD using Paracoccus yeei bacteria isolated from activated sludge. 3 Biotech 2020; 10:207. [PMID: 32346498 DOI: 10.1007/s13205-020-02199-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 04/08/2020] [Indexed: 10/24/2022] Open
Abstract
This work investigated the properties of Paracoccus yeei VKM B-3302 bacteria isolated from activated sludge and immobilized in an N-vinylpyrrolidone-modified poly(vinyl alcohol) matrix. The developed hydrogel formed a network structure to enable the entrapment of microbial cells with their viability and biocatalytic properties preserved, which ensured the technological possibility of replicating expendable biosensor receptor elements. A new ratio of the components for the synthesis selected in this work enabled producing a copolymer of an earlier undescribed chemical structure, which can be efficiently used for immobilization of highly sensitive P. yeei bacteria. A biological oxygen demand (BOD) biosensor with these bacteria and matrix was shown to possess a long-time stability exceeding that described earlier, to have a broad substrate specificity and to exceed approximately tenfold the nearest analogues by its sensitivity and the lower boundary value of 0.05 mg/dm3. The biosensor enabled assays of water samples initially attributed to pure samples (the BOD range, 0.05-5.0 mg/dm3). BOD assays of water samples from various sources showed the use of the receptor element of this composition to enable the data that closely correlated with the standard method (R 2 = 0.9990).
Collapse
|
9
|
Wang S, Tian S, Zhang P, Ye J, Tao X, Li F, Zhou Z, Nabi M. Enhancement of biological oxygen demand detection with a microbial fuel cell using potassium permanganate as cathodic electron acceptor. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2019; 252:109682. [PMID: 31610444 DOI: 10.1016/j.jenvman.2019.109682] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 09/20/2019] [Accepted: 10/05/2019] [Indexed: 06/10/2023]
Abstract
When dual-chamber microbial fuel cell (MFC) is used to detect biochemical oxygen demand (BOD), dissolved oxygen is traditionally used as cathodic electron acceptor. The detection limit of this MFC-based BOD biosensor is usually lower than 200 mg/L. In this paper, the startup of MFC-based BOD biosensor was researched and the external resistor of MFC was optimized. Results showed that the MFC started up with the dissolved oxygen as cathodic electron acceptor within 10 d, and the external resistor was optimized as 500 Ω to ensure the maximum output power of MFC. Dissolved oxygen and potassium permanganate (KMnO4) were used as cathodic electron acceptor to run MFC for detection of wastewater BOD, and the performances of two kinds of BOD biosensors were compared. The MFC-based BOD biosensor using KMnO4 (10 mmol/L) as cathodic electron acceptor exhibited an excellent performance, compared with that using dissolved oxygen. The upper limit of BOD detection was greatly broadened to 500 mg/L, the response time was shortened by 50% for artificial wastewater with a BOD of 100 mg/L, and the relative error of BOD detection was reduced to less than 10%. The MFC-based BOD biosensor using KMnO4 as cathodic electron acceptor showed a better linear relationship (R2 > 0.992) between the electric charge and BOD concentration within a BOD range of 25-500 mg/L. The MFC-based BOD biosensor using the KMnO4 as cathodic electron acceptor is promising with a better application prospect.
Collapse
Affiliation(s)
- Siqi Wang
- Beijing Key Lab for Source Control Technology of Water Pollution, Beijing Forestry University, Beijing, 100083, China
| | - Shuai Tian
- Beijing Key Lab for Source Control Technology of Water Pollution, Beijing Forestry University, Beijing, 100083, China
| | - Panyue Zhang
- Beijing Key Lab for Source Control Technology of Water Pollution, Beijing Forestry University, Beijing, 100083, China.
| | - Junpei Ye
- Beijing Key Lab for Source Control Technology of Water Pollution, Beijing Forestry University, Beijing, 100083, China
| | - Xue Tao
- Beijing Key Lab for Source Control Technology of Water Pollution, Beijing Forestry University, Beijing, 100083, China
| | - Fan Li
- Beijing Key Lab for Source Control Technology of Water Pollution, Beijing Forestry University, Beijing, 100083, China
| | - Zeyan Zhou
- Beijing Key Lab for Source Control Technology of Water Pollution, Beijing Forestry University, Beijing, 100083, China
| | - Mohammad Nabi
- Beijing Key Lab for Source Control Technology of Water Pollution, Beijing Forestry University, Beijing, 100083, China
| |
Collapse
|
10
|
Pham TTP, Nguyen PHD, Nguyen TTV, Duong HTL. Self-build packed-bed bioreactor for rapid and effective BOD estimation. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2019; 26:25656-25667. [PMID: 31267402 DOI: 10.1007/s11356-019-05711-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Accepted: 06/07/2019] [Indexed: 06/09/2023]
Abstract
This work demonstrated a simple, low-cost, rapid, and effective biochemical oxygen demand (BOD) estimation system based on a packed-bed bioreactor that can be easily self-built on-site at a particular wastewater treatment plant for continuous monitoring of the influent and effluent. The use of natural microbial consortium that were collected from the target wastewater and immobilized on a cheap porous carrier simply by adhesion resulted in an acceptable accuracy of over 95%. The newly developed semi-continuous operating mode with peak-type signals was shown to be able to continuously estimate BOD at a high flow rate to overcome the flow dependence of the oxygen electrode, limit clogging issues, enhance the response time, and lower the limit of detection. The resulting packed-bed bioreactors could work continuously for 22 h with a coefficient of variance (CoV) of only 1.8% or for 13 h a day for several days with a maximum CoV of 1.4% and their response was observed to be stable over 80 consecutive measurements. They exhibited stable responses at a wide pH range of 6.5-8.5, which is also the recommended range for aerobic wastewater treatment, emphasizing the greater ease of use of natural microorganisms for BOD estimation.
Collapse
Affiliation(s)
- Thi Thuy Phuong Pham
- Institute of Chemical Technology, Vietnam Academy of Science and Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam.
| | - Phuc Hoang Duy Nguyen
- Institute of Chemical Technology, Vietnam Academy of Science and Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
| | - Thi Thuy Van Nguyen
- Institute of Chemical Technology, Vietnam Academy of Science and Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
| | - Huynh Thanh Linh Duong
- Institute of Chemical Technology, Vietnam Academy of Science and Technology, 1 Mac Dinh Chi Street, District 1, Ho Chi Minh City, Vietnam
| |
Collapse
|
11
|
Nakamura H. Current status of water environment and their microbial biosensor techniques - Part II: Recent trends in microbial biosensor development. Anal Bioanal Chem 2018; 410:3967-3989. [PMID: 29736704 DOI: 10.1007/s00216-018-1080-0] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 04/07/2018] [Accepted: 04/12/2018] [Indexed: 12/20/2022]
Abstract
In Part I of the present review series, I presented the current state of the water environment by focusing on Japanese cases and discussed the need to further develop microbial biosensor technologies for the actual water environment. I comprehensively present trends after approximately 2010 in microbial biosensor development for the water environment. In the first section, after briefly summarizing historical studies, recent studies on microbial biosensor principles are introduced. In the second section, recent application studies for the water environment are also introduced. Finally, I conclude the present review series by describing the need to further develop microbial biosensor technologies. Graphical abstract Current water pollution indirectly occurs by anthropogenic eutrophication (Part I). Recent trends in microbial biosensor development for water environment are described in part II of the present review series.
Collapse
Affiliation(s)
- Hideaki Nakamura
- Department of Liberal Arts, Tokyo University of Technology, 1404-1 Katakura, Hachioji, Tokyo, 192-0982, Japan.
| |
Collapse
|
12
|
A Mediated BOD Biosensor Based on Immobilized B. Subtilis on Three-Dimensional Porous Graphene-Polypyrrole Composite. SENSORS 2017; 17:s17112594. [PMID: 29125543 PMCID: PMC5713028 DOI: 10.3390/s17112594] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2017] [Revised: 10/19/2017] [Accepted: 11/07/2017] [Indexed: 12/11/2022]
Abstract
We have developed a novel mediated biochemical oxygen demand (BOD) biosensor based on immobilized Bacillus subtilis (B. subtilis) on three-dimensional (3D) porous graphene-polypyrrole (rGO-PPy) composite. The 3D porous rGO-PPy composite was prepared using hydrothermal method following with electropolymerization. Then the 3D porous rGO-PPy composite was used as a support for immobilizing negatively charged B. subtilis denoted as rGO-PPy-B through coordination and electrostatic interaction. Further, the prepared rGO-PPy-B was used as a microbial biofilm for establishing a mediated BOD biosensor with ferricyanide as an electronic acceptor. The indirect determination of BOD was performed by electrochemical measuring ferrocyanide generated from a reduced ferricyanide mediator using interdigited ultramicroelectrode array (IUDA) as the working electrode. The experimental results suggested a good linear relationship between the amperometric responses and BOD standard concentrations from 4 to 60 mg/L, with a limit detection of 1.8 mg/L (S/N ≥ 3). The electrochemical measurement of real water samples showed a good agreement with the conventional BOD₅ method, and the good anti-interference as well as the long-term stability were well demonstrated, indicating that the proposed mediated BOD biosensor in this study holds a potential practical application of real water monitoring.
Collapse
|
13
|
Li Y, Sun J, Wang J, Bian C, Tong J, Li Y, Xia S. A microbial electrode based on the co-electrodeposition of carboxyl graphene and Au nanoparticles for BOD rapid detection. Biochem Eng J 2017. [DOI: 10.1016/j.bej.2017.03.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Comparison of Two Types of Overoxidized PEDOT Films and Their Application in Sensor Fabrication. SENSORS 2017; 17:s17030628. [PMID: 28335500 PMCID: PMC5375914 DOI: 10.3390/s17030628] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Revised: 03/16/2017] [Accepted: 03/17/2017] [Indexed: 11/16/2022]
Abstract
Poly(3,4-ethylenedioxythiophene) (PEDOT) films were prepared by electro-oxidation on Au microelectrodes in an aqueous solution. Electrolyte solutions and polymerization parameters were optimized prior to overoxidation. The effect of overoxidation time has been optimized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), which results in the film overoxidized for 45 s at 1.35 V presenting a strong adsorption. The other one-step overoxidation film prepared by direct CV ranging from −0.6 V to 1.35 V was polymerized for comparison. Scanning electron microscope (SEM) analysis and Fourier transform infrared (FTIR) spectroscopy were used for monitoring morphological changes and the evolution of functional groups. Both of them indicate increased abundant oxygen functional groups and roughness, yet the products exhibit dendritic morphology and piles of spherical protrusions, respectively. Moreover, double-step overoxidized film showed better electrochemical performance toward lead ion sensing. These characterizations highlight some novel properties that may be beneficial for specific sensing applications.
Collapse
|
15
|
Wang J, Li Y, Bian C, Tong J, Fang Y, Xia S. Ultramicroelectrode array modified with magnetically labeled Bacillus subtilis, palladium nanoparticles and reduced carboxy graphene for amperometric determination of biochemical oxygen demand. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-2055-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|