1
|
Garg S, Sachdeva A, Peeters M, McClements J. Point-of-Care Prostate Specific Antigen Testing: Examining Translational Progress toward Clinical Implementation. ACS Sens 2023; 8:3643-3658. [PMID: 37830899 PMCID: PMC10616866 DOI: 10.1021/acssensors.3c01402] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 09/18/2023] [Indexed: 10/14/2023]
Abstract
Prostate cancer (PCa) is the second most common male cancer and is attributable to over 375,000 deaths annually. Prostate specific antigen (PSA) is a key biomarker for PCa and therefore measuring patient PSA levels is an important aspect of the diagnostic pathway. Automated immunoassays are currently utilized for PSA analysis, but they require a laboratory setting with specialized equipment and trained personnel. This results in high diagnostic costs, extended therapeutic turnaround times, and restrictions on testing capabilities in resource-limited settings. Consequently, there is a strong drive to develop point-of-care (PoC) PSA tests that can offer accurate, low-cost, and rapid results at the time and place of the patient. However, many emerging PoC tests experience a trade-off between accuracy, affordability, and accessibility which distinctly limits their translational potential. This review comprehensively assesses the translational advantages and limitations of emerging laboratory-level and commercial PoC tests for PSA determination. Electrochemical and optical PSA sensors from 2013 to 2023 are systematically examined. Furthermore, we suggest how the translational potential of emerging tests can be optimized to achieve clinical implementation and thus improve PCa diagnosis globally.
Collapse
Affiliation(s)
- Saweta Garg
- Merz
Court, School of Engineering, Newcastle
University, Claremont Road, NE1 7RU Newcastle upon Tyne, U.K.
- Department
of Chemical Engineering and Analytical Science, School of Engineering, University of Manchester, Manchester M20 4BX, U.K.
| | - Ashwin Sachdeva
- Division
of Cancer Sciences, University of Manchester, Wilmslow Road, Manchester M20 4BX, U.K.
- Department
of Urology, The Christie NHS Foundation
Trust, Manchester M20 4BX, U.K.
| | - Marloes Peeters
- Merz
Court, School of Engineering, Newcastle
University, Claremont Road, NE1 7RU Newcastle upon Tyne, U.K.
| | - Jake McClements
- Merz
Court, School of Engineering, Newcastle
University, Claremont Road, NE1 7RU Newcastle upon Tyne, U.K.
| |
Collapse
|
2
|
Rahn KL, Peramune U, Zhang T, Anand RK. Label-Free Electrochemical Methods for Disease Detection. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2023; 16:49-69. [PMID: 36854209 DOI: 10.1146/annurev-anchem-091622-085754] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Label-free electrochemical biosensing leverages the advantages of label-free techniques, low cost, and fewer user steps, with the sensitivity and portability of electrochemical analysis. In this review, we identify four label-free electrochemical biosensing mechanisms: (a) blocking the electrode surface, (b) allowing greater access to the electrode surface, (c) changing the intercalation or electrostatic affinity of a redox probe to a biorecognition unit, and (d) modulating ion or electron transport properties due to conformational and surface charge changes. Each mechanism is described, recent advancements are summarized, and relative advantages and disadvantages of the techniques are discussed. Furthermore, two avenues for gaining further diagnostic information from label-free electrochemical biosensors, through multiplex analysis and incorporating machine learning, are examined.
Collapse
Affiliation(s)
- Kira L Rahn
- Department of Chemistry, Colorado State University, Fort Collins, Colorado, USA
- Department of Chemistry, Iowa State University, Ames, Iowa, USA;
| | - Umesha Peramune
- Department of Chemistry, Iowa State University, Ames, Iowa, USA;
| | - Tianyi Zhang
- Department of Chemistry, Iowa State University, Ames, Iowa, USA;
| | - Robbyn K Anand
- Department of Chemistry, Iowa State University, Ames, Iowa, USA;
| |
Collapse
|
3
|
He X, Deng L, Shi L, Deng Y, Zhou T, Wen L. The interaction between silica flat substrate and functional group–modified nanoparticles. Electrophoresis 2022; 43:1984-1992. [DOI: 10.1002/elps.202100262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 04/27/2022] [Accepted: 05/10/2022] [Indexed: 11/06/2022]
Affiliation(s)
- Xiaohan He
- Mechanical and Electrical Engineering College Hainan University Haikou Hainan P. R. China
| | - Luyu Deng
- Mechanical and Electrical Engineering College Hainan University Haikou Hainan P. R. China
| | - Liuyong Shi
- Mechanical and Electrical Engineering College Hainan University Haikou Hainan P. R. China
| | - Yongbo Deng
- State Key Laboratory of Applied Optics Changchun Institute of Optics Fine Mechanics and Physics (CIOMP) Chinese Academy of Sciences Changchun Jilin P. R. China
| | - Teng Zhou
- Mechanical and Electrical Engineering College Hainan University Haikou Hainan P. R. China
| | - Liping Wen
- CAS Key Laboratory of Bio‐inspired Materials and Interfacial Science Technical Institute of Physics and Chemistry Chinese Academy of Sciences Beijing P. R. China
| |
Collapse
|
4
|
Antibody immobilization for immunosensing. ANAL SCI 2022; 38:1-2. [DOI: 10.1007/s44211-021-00019-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
5
|
Srinivasan B, Nanus DM, Erickson D, Mehta S. Highly portable quantitative screening test for prostate-specific antigen at point of care. CURRENT RESEARCH IN BIOTECHNOLOGY 2022; 3:288-299. [PMID: 35083431 PMCID: PMC8789004 DOI: 10.1016/j.crbiot.2021.11.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Abstract
Prostate cancer (PCa) is the second most diagnosed cancer among men. Targeted PCa screening may decrease PCa-specific mortality. Prostate-specific antigen (PSA) is the most reliable and widely accepted tumor biomarker for screening and monitoring PCa status. However, in many settings, quantification of serum PSA requires access to centralized laboratories. In this study, we describe a proof-of-concept rapid test combined with a highly portable Cube™ reader for quantification of total PSA from a drop of serum within 20 min. We demonstrated the application of gold nanoshells as a label for lateral flow assay with significant increase in the measured colorimetric signal intensity to achieve five times lower detection limit when compared to the traditionally used 40 nm gold nanosphere labels, without a need for any additional signal amplification steps. We first optimized and evaluated the performance of the assay with commercially available total PSA calibrators. For initial validation with commercially available ACCESS Hybritech PSA calibrator, a detection range of 0.5-150 ng/mL was achieved. We compared the performance of our total PSA test with IMMULITE analyzer for quantification of total PSA in archived human serum samples. On preliminary testing with archived serums samples and comparison with IMMULITE total PSA assay, a correlation of 0.95 (p < .0001) was observed. The highly portable quantitative screening test for PSA described in this study has the potential to make PCa screening more accessible where diagnostic labs and automated immunoassay systems are not available, to reduce therapeutic turnaround time, to streamline clinical care, and to direct patient care for both initial screening and for post-treatment monitoring of patients.
Collapse
Affiliation(s)
- Balaji Srinivasan
- Division of Nutritional Sciences, Cornell University, Ithaca, NY 14853, USA.,Institute for Nutritional Sciences, Global Health, and Technology (INSiGHT), Ithaca, NY, USA
| | - David M Nanus
- Division of Hematology and Medical Oncology, Department of Medicine, Weill Cornell Medicine, New York, NY, USA
| | - David Erickson
- Division of Nutritional Sciences, Cornell University, Ithaca, NY 14853, USA.,Institute for Nutritional Sciences, Global Health, and Technology (INSiGHT), Ithaca, NY, USA.,Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA
| | - Saurabh Mehta
- Division of Nutritional Sciences, Cornell University, Ithaca, NY 14853, USA.,Institute for Nutritional Sciences, Global Health, and Technology (INSiGHT), Ithaca, NY, USA
| |
Collapse
|
6
|
Chen Y, Yu F, Wang Y, Liu W, Ye J, Xiao J, Liu X, Jiang H, Wang X. Recent Advances in Engineered Noble Metal Nanomaterials as a Surface-Enhanced Raman Scattering Active Platform for Cancer Diagnostics. J Biomed Nanotechnol 2022; 18:1-23. [PMID: 35180897 DOI: 10.1166/jbn.2022.3246] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Recently, noble metal nanomaterials have been extensively studied in the fields of biosensing, environmental catalysis, and cancer diagnosis and treatment, due to their excellent electrical conductivity, high surface area, and individual physical and optical properties. Early research on the surface-enhanced Raman scattering (SERS) effect was focused on the cognition of the SERS phenomenon and enhancing its sensitivity for single-molecule detection. With the development of nanomaterials and nanotechnology, the advances and applications based on SERS substrates have been accelerated. Among them, noble metal nanomaterials are mainly used as SERS-active substrates to enhance SERS signals owing to their compelling surface plasmon resonance (SPR) properties. This review provides recent advances, perspectives, and challenges in SERS assays based on engineered noble metal nanomaterials for early cancer diagnosis.
Collapse
Affiliation(s)
- Yun Chen
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Fangfang Yu
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Yihan Wang
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Weiwei Liu
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Jing Ye
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Jiang Xiao
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Xiaohui Liu
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Hui Jiang
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Xuemei Wang
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
7
|
Numan A, Singh S, Zhan Y, Li L, Khalid M, Rilla K, Ranjan S, Cinti S. Advanced nanoengineered-customized point-of-care tools for prostate-specific antigen. Mikrochim Acta 2021; 189:27. [PMID: 34905090 DOI: 10.1007/s00604-021-05127-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 12/02/2021] [Indexed: 01/06/2023]
Abstract
Change in the level of human prostate-specific antigen (PSA) is a major element in the development and progression of prostate cancer (PCa). Most of the methodologies are currently restricted to their application in routine clinical screening due to the scarcity of adequate screening tools, false reading, long assay time, and cost. Innovative techniques and the integration of knowledge from a variety of domains, such as materials science and engineering, are needed to provide sustainable solutions. The convergence of precision point-of-care (POC) diagnostic techniques, which allow patients to respond in real time to changes in PSA levels, provides promising possibilities for quantitative and quantitative detection of PSA. This solution could be interesting and relevant for use in PCa diagnosis at the POC. The approaches enable low-cost real-time detection and are simple to integrate into user-friendly sensor devices. This review focuses on the investigations, prospects, and challenges associated with integrating engineering sciences with cancer biology to develop nanotechnology-based tools for PCa diagnosis. This article intends to encourage the development of new nanomaterials to construct high-performance POC devices for PCa detection. Finally, the review concludes with closing remarks and a perspective forecast.
Collapse
Affiliation(s)
- Arshid Numan
- Graphene & Advanced 2D Materials Research Group (GAMRG), School of Engineering and Technology, Sunway University, No. 5, Jalan Universiti, Bandar Sunway, 47500, Petaling Jaya, Selangor, Malaysia
| | - Sima Singh
- IES Institute of Pharmacy, IES University Campus, Kalkheda, Ratibad Main Road, Bhopal, 462044, Madhya Pradesh, India.,Department of Pharmacy, University of Naples "Federico II", Via D. Montesano 49, 80131, Naples, Italy
| | - Yiqiang Zhan
- State Key Laboratory of ASIC and System, SIST, Fudan University, Shanghai, 200433, China
| | - Lijie Li
- College of Engineering, Swansea University, Swansea, SA1 8EN, UK
| | - Mohammad Khalid
- Graphene & Advanced 2D Materials Research Group (GAMRG), School of Engineering and Technology, Sunway University, No. 5, Jalan Universiti, Bandar Sunway, 47500, Petaling Jaya, Selangor, Malaysia
| | - Kirsi Rilla
- Institute of Biomedicine, University of Eastern Finland, P.O.Box 1627, 70211, Kuopio, Finland
| | - Sanjeev Ranjan
- Institute of Biomedicine, University of Eastern Finland, P.O.Box 1627, 70211, Kuopio, Finland
| | - Stefano Cinti
- Department of Pharmacy, University of Naples "Federico II", Via D. Montesano 49, 80131, Naples, Italy. .,BAT Center - Interuniversity Center for Studies on Bioinspired Agro-Environmental Technology, University of Napoli Federico II, 80055, Naples, Italy.
| |
Collapse
|
8
|
Biocompatible Osmium Telluride-Polypyrrole Nanocomposite Material: Application in Prostate Specific Antigen Immunosensing. Processes (Basel) 2021. [DOI: 10.3390/pr9122203] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Prostate cancer is a dominant global threat to society. It affects nearly 4000 men in South Africa annually, making it the second most threatening cancerous disease after lung cancer. A potential serological biomarker to monitor early diagnosis of prostate cancer is prostate specific antigen (PSA). We used the PSA biomarker in our work to develop an extremely sensitive electrochemical immunosensor to achieve low detection limits. The fabrication steps followed with the combination of thioglycolic acid capped osmium telluride quantum dots (TGA-OsTe2QD)-polypyrrole (PPy) nanocomposite and prostate specific antigen modified on a glassy carbon electrode. The UV-Vis signatures of TGA-OsTe2QD-PPy showed an absorption band at 262 nm which is attributed to the PPy and TGA-OsTe2QD composite. This band corresponds to the energy band gap of 4.4 and 5.4 eV. The CV responses of BSA|Ab|TGA-OsTe2QD|PPy|GCE modified electrode to prostate specific antigen (PSA) was studied within a range of 0–16 ng/mL PSA that was linear, herein referred to as liner range (LR), which produced a limit of detection (LOD) value of 0.36 ng/mL PSA. The values of the immunosensor’s calibration parameters (LR and LOD) make them suitable for real sample application, due to their coverage of the PSA concentration range (0–14 ng/mL) that is of clinical importance.
Collapse
|
9
|
Dowlatshahi S, Abdekhodaie MJ. Electrochemical prostate-specific antigen biosensors based on electroconductive nanomaterials and polymers. Clin Chim Acta 2021; 516:111-135. [PMID: 33545110 DOI: 10.1016/j.cca.2021.01.018] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 01/23/2021] [Accepted: 01/26/2021] [Indexed: 01/11/2023]
Abstract
Prostate cancer (PCa), the second most malignant neoplasm in men, is also the fifth leading cause of cancer-related deaths in men globally. Unfortunately, this malignancy remains largely asymptomatic until late-stage emergence when treatment is limited due to the lack of effective metastatic PCa therapeutics. Due to these limitations, early PCa detection through prostate-specific antigen (PSA) screening has become increasingly important, resulting in a more than 50% decrease in mortality. Conventional assays for PSA detection, such as enzyme-linked immunosorbent assay (ELISA), are labor intensive, relatively expensive, operator-dependent and do not provide adequate sensitivity. Electrochemical biosensors overcome these limitations because they are rapid, cost-effective, simple to use and ultrasensitive. This article reviews electrochemical PSA biosensors using electroconductive nanomaterials such as carbon-, metal-, metal oxide- and peptide-based nanostructures, as well as polymers to significantly improve conductivity and enhance sensitivity. Challenges associated with the development of these devices are discussed thus providing additional insight into their analytic strength as well as their potential use in early PCa detection.
Collapse
Affiliation(s)
- Sayeh Dowlatshahi
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Mohammad J Abdekhodaie
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran; Yeates School of Graduate Studies, Ryerson University, Toronto, Ontario, Canada.
| |
Collapse
|
10
|
Zhou T, Deng L, Shi L, Li T, Zhong X, Wen L. Brush Layer Charge Characteristics of a Biomimetic Polyelectrolyte-Modified Nanoparticle Surface. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:15220-15229. [PMID: 33305573 DOI: 10.1021/acs.langmuir.0c02417] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Nanoparticle surface charge regulation technology plays an important role in ion rectification, drug delivery, and cell biology. The biomimetic polyelectrolyte can be combined with nanoparticles by nanomodification technology to form a layer of coating, which is called the brush layer of nanoparticles. In this study, based on the Poisson-Nernst-Planck (PNP) equation system, a theoretical model considering a bionic electrolyte brush layer with charge density regulated by a chemical reaction is constructed. The charge properties of brushed nanoparticles are studied by changing the sizes of nanoparticles, the pH value of the solution, background salt solution concentration, and brush layer thickness. The result shows that the charge density of brushed nanoparticles increases with the increase of particle size. The isoelectric point (IEP) of the equilibrium reaction against the brush layer is pH = 5.5. When the pH < 5.5, the charge density of the particle brush layers decreases with the increase of pH, and when the pH > 5.5, the charge density of the particle brush layer increases with the increase of pH. By comparing the charge density of different brush thicknesses, it is found that the larger the brush thickness, the smaller the charge density of the brush layer. This research provides theoretical support for the change of the through pore velocity when macromolecular organic compounds pass through nanopores.
Collapse
Affiliation(s)
- Teng Zhou
- Mechanical and Electrical Engineering College, Hainan University, Haikou, 570228 Hainan, China
| | - Luyu Deng
- Mechanical and Electrical Engineering College, Hainan University, Haikou, 570228 Hainan, China
| | - Liuyong Shi
- Mechanical and Electrical Engineering College, Hainan University, Haikou, 570228 Hainan, China
| | - Ting Li
- Institute of Biomedical Engineering, Chinese Academy of Medical Science and Peking Union Medical Collage, Tianjin 100730, China
| | - Xiangtao Zhong
- Mechanical and Electrical Engineering College, Hainan University, Haikou, 570228 Hainan, China
| | - Liping Wen
- CAS Key Laboratory of Bio-Inspired Materials and Interfacial Science, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| |
Collapse
|
11
|
An ultrasensitive label-free electrochemical immunosensor based on 3D porous chitosan-graphene-ionic liquid-ferrocene nanocomposite cryogel decorated with gold nanoparticles for prostate-specific antigen. Talanta 2020; 224:121787. [PMID: 33379016 DOI: 10.1016/j.talanta.2020.121787] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 10/12/2020] [Accepted: 10/15/2020] [Indexed: 12/14/2022]
Abstract
A highly sensitive and selective label-free electrochemical immunosensor was successfully fabricated for measuring prostate-specific antigen (PSA). A composite of chitosan, graphene, ionic liquid and ferrocene (CS-GR-IL-Fc) was drop casted onto a screen-printed carbon electrode (SPCE) and frozen to create a layer of 3D porous cryogel (CS-GR-IL-Fc cry) which was decorated with gold nanoparticles (AuNPs). The biocompatibility and porosity of the cryogel increased the surface area available for AuNPs loading via amino groups and the population of anti-PSA, immobilized on the AuNPs via chemisorption, could be increased. The CS-GR-IL-Fc cry displayed excellent conductivity, enhancing electron transfer and amplifying the current signal. Differential pulse voltammetry was employed to determine PSA by measuring the reduction in the Fc oxidation peak current in response to the formation of PSA/anti-PSA immunocomplex. Under the optimized incubation time and electrolyte pH, the developed immunosensor displayed excellent analytical performances, including a wide linear range at concentrations from 1.0 × 10-7 to 1.0 × 10-1 ng mL-1, with a very low limit of detection of 4.8 × 10-8 ng mL-1 and good reproducibility (relative standard deviation of <4.6%, n = 6), stability (90% sensitivity within 20 days), repeatability (12 cycles of binding-rebinding, the sensitivity > 90%) and selectivity. The results obtained from the device for the determination of PSA in human serum were consistent with results from the enzyme-linked immunosorbent assay (P > 0.05), and indicated the promising potential of the proposed immunosensor in clinical diagnosis.
Collapse
|
12
|
Sensitive competitive label-free electrochemical immunosensor for primal detection of ovarian cancer. CHEMICAL PAPERS 2020. [DOI: 10.1007/s11696-020-01100-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
13
|
Miyao H, Uemura U, Sueda S. Stepwise Preparation of a Polymer Comprising Protein Building Blocks on a Solid Support for Immunosensing Platform. ANAL SCI 2020; 36:213-217. [PMID: 31548440 DOI: 10.2116/analsci.19p318] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In immunosensing, immobilization of the antibody on the sensing platform significantly influences the performance of the sensor. Herein, we propose a novel antibody-immobilization method based on a protein-polymer chain containing multiple copies of an antibody-binding protein, the Z-domain. In our approach, the Z-domain-containing polymer is prepared on the surface of the sensing platform with a biotinylation reaction from the archaeon Sulfolobus tokodaii. Biotinylation from S. tokodaii has a unique property by which biotin protein ligase (BPL) forms an extremely stable complex with its biotinylated substrate protein (BCCP). Here, we employed two types of engineered proteins: one was the fusion protein of BCCP with the Z-domain (BZB), in which BCCP was genetically attached to the N- and C-termini of the Z-domain; the other was a BPL dimer prepared by connecting two BPL molecules with a cross-linking reagent. We applied these two engineered proteins alternately onto the BPL-modified solid support of the surface plasmon resonance sensor chip, and succeeded in growing polymer chains comprising multiple units of BZB and the BPL dimer. The antibody-binding capability of the Z-domain-containing polymer thus prepared is adjustable by controlling the number of cycles of protein addition and the surface density of the polymer on the solid support.
Collapse
Affiliation(s)
- Hiroki Miyao
- Department of Bioscience and Bioinformatics, Kyushu Institute of Technology
| | - Utaro Uemura
- Department of Bioscience and Bioinformatics, Kyushu Institute of Technology
| | - Shinji Sueda
- Department of Bioscience and Bioinformatics, Kyushu Institute of Technology.,Research Center for Bio-microsensing Technology, Kyushu Institute of Technology
| |
Collapse
|
14
|
Negahdary M, Sattarahmady N, Heli H. Advances in prostate specific antigen biosensors-impact of nanotechnology. Clin Chim Acta 2020; 504:43-55. [PMID: 32004532 DOI: 10.1016/j.cca.2020.01.028] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/25/2020] [Accepted: 01/27/2020] [Indexed: 01/01/2023]
Abstract
Prostate cancer is one of the most dangerous and deadly cancers in elderly men. Early diagnosis using prostate-specific antigen (PSA) facilitates disease detection, management and treatment. Biosensors have recently been used as sensitive, selective, inexpensive and rapid diagnostic tools for PSA detection. In this review, a variety of PSA biosensors such as aptasensors, peptisensors and immunesensors are highlighted. These use aptamers, peptides and antibodies in the biorecognition element, respectively, and can detect PSA with very high sensitivity via electrochemical, electrochemiluminescence, fluorescence and surface-enhanced Raman spectroscopy. To improve the sensitivity of most of these PSA biosensors, different nanostructured materials have played a critical role.
Collapse
Affiliation(s)
- M Negahdary
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - N Sattarahmady
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Department of Medical Physics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - H Heli
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|
15
|
Farshchi F, Hasanzadeh M, Mokhtarzadeh A. A novel electroconductive interface based on Fe
3
O
4
magnetic nanoparticle and cysteamine functionalized AuNPs: Preparation and application as signal amplification element to minoring of antigen‐antibody immunocomplex and biosensing of prostate cancer. J Mol Recognit 2019; 33:e2825. [DOI: 10.1002/jmr.2825] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Revised: 10/16/2019] [Accepted: 10/23/2019] [Indexed: 12/20/2022]
Affiliation(s)
- Fatemeh Farshchi
- Department of BiochemistryHigher Education Institute of Rab‐Rashid Tabriz Iran
- Biotechnology Research CenterTabriz University of Medical Sciences Tabriz Iran
| | - Mohammad Hasanzadeh
- Pharmaceutical Analysis Research CenterTabriz University of Medical Sciences Tabriz Iran
| | - Ahad Mokhtarzadeh
- Immunology Research CenterTabriz University of Medical Sciences Tabriz Iran
| |
Collapse
|
16
|
Filik H, Avan AA. Nanostructures for nonlabeled and labeled electrochemical immunosensors: Simultaneous electrochemical detection of cancer markers: A review. Talanta 2019; 205:120153. [PMID: 31450406 DOI: 10.1016/j.talanta.2019.120153] [Citation(s) in RCA: 72] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 07/09/2019] [Accepted: 07/12/2019] [Indexed: 12/14/2022]
Abstract
The simultaneous electrochemical determination of multiple tumor antigens has attracted a great deal of attention, which can effectively enhance the capability and accuracy of the analysis. Nanostructured materials mostly played a key major role in the electrochemical immunosensors fabrication and operation improvement. This review focused mainly on the protocols for using nanostructures to fabricate electrochemical (nonlabeled@label-free and labeled@sandwich-type) immunosensors. Furthermore, this review has also described the diverse classes of electroactive nanospecies which are a complementary part of any immunosensor that assists to reach the selectivity for the target antigen. Finally, the important analytical characteristics of the published immunosensors were discussed (electrochemical detection technique, linear range, and detection limit). Studies published between the years 2009-2018 have been included in this review.
Collapse
Affiliation(s)
- Hayati Filik
- Istanbul University-Cerrahpaşa, Faculty of Engineering, Department of Chemistry, 34320 Avcılar, Istanbul, Turkey.
| | - A Aslıhan Avan
- Istanbul University-Cerrahpaşa, Faculty of Engineering, Department of Chemistry, 34320 Avcılar, Istanbul, Turkey
| |
Collapse
|
17
|
Khan MS, Dighe K, Wang Z, Srivastava I, Daza E, Schwartz-Dual AS, Ghannam J, Misra SK, Pan D. Detection of prostate specific antigen (PSA) in human saliva using an ultra-sensitive nanocomposite of graphene nanoplatelets with diblock-co-polymers and Au electrodes. Analyst 2019; 143:1094-1103. [PMID: 29387841 DOI: 10.1039/c7an01932g] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Prostate-specific antigen (PSA) is a commonly used biomarker for the detection of prostate cancer (PCa) and there are numerous data available for its invasive detection in the serum and whole blood. In this work, an electrochemical sensing method was devised to detect traces of PSA in human saliva using a hybrid nanocomposite of graphene nanoplatelets with diblock co-polymers and Au electrodes (GRP-PS67-b-PAA27-Au). The pure graphitic composition on filter paper provides significantly high electrical and thermal conductivity while PS67-b-PAA27 makes an amphiphilic bridge between GRP units. The sensor utilizes the binding of an anti-PSA antibody with an antigen-PSA to act as a resistor in a circuit providing an impedance change that in turn allows for the detection and quantification of PSA in saliva samples. A miniaturized electrical impedance analyzer was interfaced with a sensor chip and the data were recorded in real-time using a Bluetooth-enabled module. This fully integrated and optimized sensing device exhibited a wide PSA range of detection from 0.1 pg mL-1 to 100 ng mL-1 (R2 = 0.963) with a lower limit of detection of 40 fg mL-1. The performance of the biosensor chip was validated with an enzyme-linked immunosorbent assay technique with a regression coefficient as high as 0.940. The advantages of the newly developed saliva-PSA electrical biosensor over previously reported serum-PSA electrochemical biosensors include a faster response time (3-5 min) to achieve a stable electrical signal for PSA detection, high selectivity, improved sensitivity, no additional requirement of a redox electrolyte for electron exchange and excellent shelf life. The presented sensor is aimed for clinical commercialization to detect PSA in human saliva.
Collapse
Affiliation(s)
- M S Khan
- Bioengineering Department, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Oliveira N, Costa-Rama E, Viswanathan S, Delerue-Matos C, Pereira L, Morais S. Label-free Voltammetric Immunosensor for Prostate Specific Antigen Detection. ELECTROANAL 2018. [DOI: 10.1002/elan.201800417] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Nélia Oliveira
- REQUIMTE/LAQV; Instituto Superior de Engenharia do Porto; Instituto Politécnico do Porto; Rua Dr. António Bernardino de Almedia 431 4200-072 Porto Portugal
| | - Estefanía Costa-Rama
- REQUIMTE/LAQV; Instituto Superior de Engenharia do Porto; Instituto Politécnico do Porto; Rua Dr. António Bernardino de Almedia 431 4200-072 Porto Portugal
| | - Subramanian Viswanathan
- Department of Industrial Chemistry; Alagappa University; Karaikudi- 630003, Tamilnadu, India
| | - Cristina Delerue-Matos
- REQUIMTE/LAQV; Instituto Superior de Engenharia do Porto; Instituto Politécnico do Porto; Rua Dr. António Bernardino de Almedia 431 4200-072 Porto Portugal
| | - Lourdes Pereira
- Department of Medical Sciences; CICECO-Aveiro Institute of Materials; University of Aveiro, Campus Santiago; 3810-193 Aveiro Portugal
| | - Simone Morais
- REQUIMTE/LAQV; Instituto Superior de Engenharia do Porto; Instituto Politécnico do Porto; Rua Dr. António Bernardino de Almedia 431 4200-072 Porto Portugal
| |
Collapse
|
19
|
Suresh L, Brahman PK, Reddy KR, J.S. B. Development of an electrochemical immunosensor based on gold nanoparticles incorporated chitosan biopolymer nanocomposite film for the detection of prostate cancer using PSA as biomarker. Enzyme Microb Technol 2018; 112:43-51. [DOI: 10.1016/j.enzmictec.2017.10.009] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 10/18/2017] [Accepted: 10/21/2017] [Indexed: 12/15/2022]
|
20
|
Pan M, Gu Y, Yun Y, Li M, Jin X, Wang S. Nanomaterials for Electrochemical Immunosensing. SENSORS (BASEL, SWITZERLAND) 2017; 17:E1041. [PMID: 28475158 PMCID: PMC5469646 DOI: 10.3390/s17051041] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Revised: 04/10/2017] [Accepted: 05/03/2017] [Indexed: 01/02/2023]
Abstract
Electrochemical immunosensors resulting from a combination of the traditional immunoassay approach with modern biosensors and electrochemical analysis constitute a current research hotspot. They exhibit both the high selectivity characteristics of immunoassays and the high sensitivity of electrochemical analysis, along with other merits such as small volume, convenience, low cost, simple preparation, and real-time on-line detection, and have been widely used in the fields of environmental monitoring, medical clinical trials and food analysis. Notably, the rapid development of nanotechnology and the wide application of nanomaterials have provided new opportunities for the development of high-performance electrochemical immunosensors. Various nanomaterials with different properties can effectively solve issues such as the immobilization of biological recognition molecules, enrichment and concentration of trace analytes, and signal detection and amplification to further enhance the stability and sensitivity of the electrochemical immunoassay procedure. This review introduces the working principles and development of electrochemical immunosensors based on different signals, along with new achievements and progress related to electrochemical immunosensors in various fields. The importance of various types of nanomaterials for improving the performance of electrochemical immunosensor is also reviewed to provide a theoretical basis and guidance for the further development and application of nanomaterials in electrochemical immunosensors.
Collapse
Affiliation(s)
- Mingfei Pan
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technolo, Tianjin 300457, China.
| | - Ying Gu
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technolo, Tianjin 300457, China.
| | - Yaguang Yun
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technolo, Tianjin 300457, China.
| | - Min Li
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technolo, Tianjin 300457, China.
| | - Xincui Jin
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technolo, Tianjin 300457, China.
| | - Shuo Wang
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technolo, Tianjin 300457, China.
| |
Collapse
|
21
|
Functional fusion proteins and prevention of electrode fouling for a sensitive electrochemical immunosensor. Anal Chim Acta 2017; 967:70-77. [DOI: 10.1016/j.aca.2017.02.026] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2016] [Revised: 02/24/2017] [Accepted: 02/27/2017] [Indexed: 01/09/2023]
|
22
|
Hasanzadeh M, Shadjou N. What are the reasons for low use of graphene quantum dots in immunosensing of cancer biomarkers? MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 71:1313-1326. [DOI: 10.1016/j.msec.2016.11.068] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Revised: 11/09/2016] [Accepted: 11/17/2016] [Indexed: 11/29/2022]
|
23
|
Zoppe JO, Ataman NC, Mocny P, Wang J, Moraes J, Klok HA. Surface-Initiated Controlled Radical Polymerization: State-of-the-Art, Opportunities, and Challenges in Surface and Interface Engineering with Polymer Brushes. Chem Rev 2017; 117:1105-1318. [PMID: 28135076 DOI: 10.1021/acs.chemrev.6b00314] [Citation(s) in RCA: 600] [Impact Index Per Article: 85.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The generation of polymer brushes by surface-initiated controlled radical polymerization (SI-CRP) techniques has become a powerful approach to tailor the chemical and physical properties of interfaces and has given rise to great advances in surface and interface engineering. Polymer brushes are defined as thin polymer films in which the individual polymer chains are tethered by one chain end to a solid interface. Significant advances have been made over the past years in the field of polymer brushes. This includes novel developments in SI-CRP, as well as the emergence of novel applications such as catalysis, electronics, nanomaterial synthesis and biosensing. Additionally, polymer brushes prepared via SI-CRP have been utilized to modify the surface of novel substrates such as natural fibers, polymer nanofibers, mesoporous materials, graphene, viruses and protein nanoparticles. The last years have also seen exciting advances in the chemical and physical characterization of polymer brushes, as well as an ever increasing set of computational and simulation tools that allow understanding and predictions of these surface-grafted polymer architectures. The aim of this contribution is to provide a comprehensive review that critically assesses recent advances in the field and highlights the opportunities and challenges for future work.
Collapse
Affiliation(s)
- Justin O Zoppe
- Institut des Matériaux and Institut des Sciences et Ingénierie Chimiques, Laboratoire des Polymères Bâtiment MXD, Ecole Polytechnique Fédérale de Lausanne (EPFL) , Station 12 CH-1015 Lausanne, Switzerland
| | - Nariye Cavusoglu Ataman
- Institut des Matériaux and Institut des Sciences et Ingénierie Chimiques, Laboratoire des Polymères Bâtiment MXD, Ecole Polytechnique Fédérale de Lausanne (EPFL) , Station 12 CH-1015 Lausanne, Switzerland
| | - Piotr Mocny
- Institut des Matériaux and Institut des Sciences et Ingénierie Chimiques, Laboratoire des Polymères Bâtiment MXD, Ecole Polytechnique Fédérale de Lausanne (EPFL) , Station 12 CH-1015 Lausanne, Switzerland
| | - Jian Wang
- Institut des Matériaux and Institut des Sciences et Ingénierie Chimiques, Laboratoire des Polymères Bâtiment MXD, Ecole Polytechnique Fédérale de Lausanne (EPFL) , Station 12 CH-1015 Lausanne, Switzerland
| | - John Moraes
- Institut des Matériaux and Institut des Sciences et Ingénierie Chimiques, Laboratoire des Polymères Bâtiment MXD, Ecole Polytechnique Fédérale de Lausanne (EPFL) , Station 12 CH-1015 Lausanne, Switzerland
| | - Harm-Anton Klok
- Institut des Matériaux and Institut des Sciences et Ingénierie Chimiques, Laboratoire des Polymères Bâtiment MXD, Ecole Polytechnique Fédérale de Lausanne (EPFL) , Station 12 CH-1015 Lausanne, Switzerland
| |
Collapse
|
24
|
Akiba U, Anzai JI. Recent Progress in Electrochemical Biosensors for Glycoproteins. SENSORS (BASEL, SWITZERLAND) 2016; 16:E2045. [PMID: 27916961 PMCID: PMC5191026 DOI: 10.3390/s16122045] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 11/22/2016] [Accepted: 11/29/2016] [Indexed: 12/20/2022]
Abstract
This review provides an overview of recent progress in the development of electrochemical biosensors for glycoproteins. Electrochemical glycoprotein sensors are constructed by combining metal and carbon electrodes with glycoprotein-selective binding elements including antibodies, lectin, phenylboronic acid and molecularly imprinted polymers. A recent trend in the preparation of glycoprotein sensors is the successful use of nanomaterials such as graphene, carbon nanotube, and metal nanoparticles. These nanomaterials are extremely useful for improving the sensitivity of glycoprotein sensors. This review focuses mainly on the protocols for the preparation of glycoprotein sensors and the materials used. Recent improvements in glycoprotein sensors are discussed by grouping the sensors into several categories based on the materials used as recognition elements.
Collapse
Affiliation(s)
- Uichi Akiba
- Graduate School of Engineering and Science, Akita University, 1-1 Tegatagaluenn-machi, Akita 010-8502, Japan.
| | - Jun-Ichi Anzai
- Graduate School of Pharmaceutical Sciences, Tohoku University, Aoba, Aramakim, Sendai 980-8578, Japan.
| |
Collapse
|
25
|
Pihikova D, Kasak P, Kubanikova P, Sokol R, Tkac J. Aberrant sialylation of a prostate-specific antigen: Electrochemical label-free glycoprofiling in prostate cancer serum samples. Anal Chim Acta 2016; 934:72-9. [PMID: 27506346 DOI: 10.1016/j.aca.2016.06.043] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 06/21/2016] [Accepted: 06/23/2016] [Indexed: 12/24/2022]
Abstract
Electrochemical detection method allowing to detect prostate-specific antigen (PSA), a biomarker of prostate cancer (PCa), with PSA glycoprofiling was applied in an analysis of PCa serum samples for the first time. Electrochemical impedance spectroscopy (EIS) as a label-free method with immobilized anti-PSA was applied for PSA detection and lectins to glycoprofile captured PSA on the same surface. A proper choice of blocking agent providing high selectivity of biosensor detection with the immobilized anti-PSA antibody was done. The biosensor could detect PSA down to 100 ag/mL with a linear concentration working range from 100 ag/mL up to 1 μg/mL, i.e. 10 orders of concentration magnitude and the sensitivity of (5.5 ± 0.2)%/decade. The results showed that a commercial carbo-free blocking solution was the best one, reducing non-specific binding 55-fold when compared to the immunosensor surface without any blocking agent applied, while allowing to detect PSA. The biosensor response obtained after addition of lectin (i.e. proportional to the amount of a particular glycan on PSA) divided by the biosensor response obtained after incubation with a sample (i.e. proportional to the PSA level in the sample) was applied to distinguish serum samples of PCa patients from those of healthy individuals. The results showed that Maackia amurensis agglutinin (MAA) recognizing α-2,3-terminal sialic acid can be applied to distinguish between these two sets of samples since the MAA/PSA response obtained from the analysis of the PCa samples was significantly higher (5.3-fold) compared to the MAA/PSA response obtained by the analysis of samples from healthy individuals. Thus, combined analysis of serological PSA levels together with PSA glycoprofiling of aberrant glycosylation of PSA (i.e. increase in the level of α-2,3-terminal sialic acid) has a potential to improve detection of PCa.
Collapse
Affiliation(s)
- Dominika Pihikova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, Bratislava, 845 38, Slovak Republic
| | - Peter Kasak
- Centre for Advanced Materials, Qatar University, P.O. Box 2713, Doha, Qatar
| | - Petra Kubanikova
- Private Urological Ambulance, Piaristicka 6, Trencin, 911 01, Slovak Republic
| | - Roman Sokol
- Private Urological Ambulance, Piaristicka 6, Trencin, 911 01, Slovak Republic
| | - Jan Tkac
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, Bratislava, 845 38, Slovak Republic.
| |
Collapse
|
26
|
Wu D, Liu Y, Wang Y, Hu L, Ma H, Wang G, Wei Q. Label-free Electrochemiluminescent Immunosensor for Detection of Prostate Specific Antigen based on Aminated Graphene Quantum Dots and Carboxyl Graphene Quantum Dots. Sci Rep 2016; 6:20511. [PMID: 26842737 PMCID: PMC4740800 DOI: 10.1038/srep20511] [Citation(s) in RCA: 82] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2015] [Accepted: 01/07/2016] [Indexed: 12/18/2022] Open
Abstract
Prostate-specific antigen (PSA) was used as the model, an ultrasensitive label-free electrochemiluminescent immunosensor was developed based on graphene quantum dots. Au/Ag-rGO was sythsized and used as electrode material to load a great deal of graphene quantum dots due to the large surface area and excellent electron conductivity. After aminated graphene quantum dots and acarboxyl graphene quantum dots were modified onto the electrode, the ECL intensity was much high using K2S2O8 as coreactant. Then, antibody of PSA was immobilized on the surface of modified electrode surface through the adsorption of Au/Ag toward proteins, leading to the decrease of the ECL intensity. As proven by ECL spectra test and electrochemical impedance spectroscopy (EIS) analysis, the fabrication process of the immunosensor is successful. Under the optimal conditions, the ECL intensity decreased linearly with the logarithm of PSA concentration in the range of 1 pg/mL ~ 10 ng/mL. The detection limit achieved is 0.29 pg/mL. The immunosensor results were validated through the detection of PSA in serum samples with satisfactory results. Due to excellent stability, high sensitivity, acceptable repeatability and selectivity, the immunosensor has promising applications in disease and drug analysis.
Collapse
Affiliation(s)
- Dan Wu
- Key Laboratory of Chemical Sensing &Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Yixin Liu
- Key Laboratory of Chemical Sensing &Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Yaoguang Wang
- Key Laboratory of Chemical Sensing &Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Lihua Hu
- Key Laboratory of Chemical Sensing &Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Hongmin Ma
- Key Laboratory of Chemical Sensing &Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Guoqin Wang
- Key Laboratory of Chemical Sensing &Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Qin Wei
- Key Laboratory of Chemical Sensing &Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| |
Collapse
|
27
|
Zhou T, Tao Y, Jin H, Song B, Jing T, Luo D, Zhou Y, Zhou Y, Lee YI, Mei S. Fabrication of a Selective and Sensitive Sensor Based on Molecularly Imprinted Polymer/Acetylene Black for the Determination of Azithromycin in Pharmaceuticals and Biological Samples. PLoS One 2016; 11:e0147002. [PMID: 26820753 PMCID: PMC4731201 DOI: 10.1371/journal.pone.0147002] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2015] [Accepted: 12/25/2015] [Indexed: 01/04/2023] Open
Abstract
A new selective and sensitive sensor based on molecularly imprinted polymer/acetylene black (MIP/AB) was developed for the determination of azithromycin (AZM) in pharmaceuticals and biological samples. The MIP of AZM was synthesized by precipitation polymerization. MIP and AB were then respectively introduced as selective and sensitive elements for the preparation of MIP/AB-modified carbon paste (MIP/ABP) electrode. The performance of the obtained sensor was estimated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. Compared with non-molecularly imprinted polymer (NIP) electrodes, NIP/ABP electrodes, and MIP-modified carbon paste electrodes, MIP/ABP electrode exhibited excellent current response toward AZM. The prepared sensor also exhibited good selectivity for AZM in comparison with structurally similar compounds. The effect of electrode composition, extraction parameters, and electrolyte conditions on the current response of the sensor was investigated. Under the optimized conditions, the prepared sensor showed two dynamic linear ranges of 1.0 × 10−7 mol L−1 to 2.0 × 10−6 mol L−1 and 2.0 × 10−6 mol L−1 to 2.0 × 10−5 mol L−1, with a limit of detection of 1.1 × 10−8 mol L−1. These predominant properties ensured that the sensor exhibits excellent reliability for detecting AZM in pharmaceuticals and biological fluids without the assistance of any separation techniques. The results were validated by the high-performance liquid chromatography–tandem mass spectrometry method.
Collapse
Affiliation(s)
- Tingting Zhou
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
| | - Yun Tao
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
| | - Hua Jin
- Department of Chemistry, Changwon National University, Changwon, 641–773, Republic of Korea
- Central Laboratory, Yanbian University Hospital, Yanji, Jilin, 133000, China
| | - Bin Song
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
| | - Tao Jing
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
| | - Dan Luo
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
| | - Yusun Zhou
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
| | - Yikai Zhou
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
| | - Yong-Ill Lee
- Department of Chemistry, Changwon National University, Changwon, 641–773, Republic of Korea
| | - Surong Mei
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Wuhan, Hubei, 430030, China
- * E-mail:
| |
Collapse
|
28
|
Shen G, Zhang X, Shen Y, Zhang C. Immobilization of antibodies on aldehyde-functionalized polymer/graphene films for the fabrication of a label-free electrochemical immunosensor. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2015.06.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
29
|
Sun Y, Du H, Deng Y, Lan Y, Feng C. Preparation of polyacrylamide via surface-initiated electrochemical-mediated atom transfer radical polymerization (SI-eATRP) for Pb2+ sensing. J Solid State Electrochem 2015. [DOI: 10.1007/s10008-015-3008-3] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
30
|
Sun G, Yang H, Zhang Y, Yu J, Ge S, Yan M, Song X. Branched zinc oxide nanorods arrays modified paper electrode for electrochemical immunosensing by combining biocatalytic precipitation reaction and competitive immunoassay mode. Biosens Bioelectron 2015; 74:823-9. [PMID: 26232677 DOI: 10.1016/j.bios.2015.07.057] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Revised: 07/23/2015] [Accepted: 07/24/2015] [Indexed: 01/21/2023]
Abstract
Branched zinc oxide nanorods (BZR) arrays, an array with high charge carries collection efficiency and specific surface area, are grown on the reduced graphene oxide-paper working electrode for the first time to construct a paper-based electrochemical (EC) immunosensor. Typically, the BZR are fabricated via a simple hydrothermal process, which can provide abundant sites for antibodies loading. By combining the large surface area of porous zinc oxide (PZS) and good biocompatibility of gold nanoparticles (AuNPs), PZS-AuNPs (PZS@Au) nanocomposites are designed to label horseradish peroxide (HRP) and antigens. After a competitive reaction between antigens and PZS@Au nanocomposites labeled antigens, the signal labels are introduced into the immunosensor, in which, HRP participate in biocatalytic precipitation process. The produced precipitate reduces the electrode surface area and hinders the electron transfer. With the increase of concentration of antigens, the signal labels introduced into the sensor decrease, thus, a signal-on immunoassay for α-fetoprotein detection is constructed. The proposed paper-based EC immunosensor combines enzymatic biocatalytic precipitation reaction and competitive immunoassay mode for the first time, and possesses a wide linear range from 0.2 pg mL(-1) to 500 ng mL(-1) with a detection limit of 0.08 pg mL(-1). In addition, the proposed method is simple, sensitive and specific and can be a promising platform for other protein detection.
Collapse
Affiliation(s)
- Guoqiang Sun
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Hongmei Yang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Yan Zhang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Jinghua Yu
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Shenguang Ge
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China; Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials, University of Jinan, Jinan 250022, China.
| | - Mei Yan
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Xianrang Song
- Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Cancer Hospital and Institute, Jinan 250117, China
| |
Collapse
|
31
|
From Self-Assembled Monolayers to Coatings: Advances in the Synthesis and Nanobio Applications of Polymer Brushes. Polymers (Basel) 2015. [DOI: 10.3390/polym7071346] [Citation(s) in RCA: 77] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
|