1
|
Zhang L, Liu G, Xia Q, Deng L. Research progress on blood compatibility of hemoperfusion adsorbent materials. Front Bioeng Biotechnol 2024; 12:1456694. [PMID: 39411060 PMCID: PMC11473396 DOI: 10.3389/fbioe.2024.1456694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Accepted: 09/19/2024] [Indexed: 10/19/2024] Open
Abstract
This comprehensive review examines the latest developments in improving the blood compatibility of hemoperfusion adsorbents. By leveraging advanced coating and modification techniques, including albumin-collodion, cellulose, hydrogel, and heparin coatings, notable enhancements in blood compatibility have been achieved across diverse adsorbent types, such as carbon-based, resin-based, and polysaccharide-based materials. Despite promising laboratory results, the intricate manufacturing processes and elevated costs present significant challenges for broad clinical application. Therefore, future endeavors should focus on cost-benefit analysis, large-scale production strategies, in-depth exploration of blood-material interactions, and innovative technologies to propel the development of safer and more effective blood purification therapies.
Collapse
Affiliation(s)
- Liangqing Zhang
- Department of Anesthesiology, The Second Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China
| | - Guohao Liu
- Department of Medical Imaging, Affiliated Hospital of Jilin Medical University, Jilin, China
| | - Qingping Xia
- Department of Science and Education, Gaozhou People’s Hospital, Gaozhou, Guangdong, China
| | - Li Deng
- Department of Cardiovascular Surgery, Gaozhou People’s Hospital, Gaozhou, Guangdong, China
| |
Collapse
|
2
|
Hou J, Liu M, Gao W, Yan K, Li B, Zheng W, Gong S, Zhang X, Sun W. Understanding the Adsorption and Diffusion Behaviors of PBUT in Biocompatible MOFs. J Phys Chem B 2024; 128:8886-8895. [PMID: 39226469 DOI: 10.1021/acs.jpcb.4c02830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/05/2024]
Abstract
With the increasing incidence of chronic kidney disease, the effective control of protein-bound uremic toxins (PBUTs), which are difficult to remove through dialysis, has become a priority. In this study, the adsorption and diffusion behaviors of several metal-organic frameworks (MOFs) for PBUTs (indoxyl sulfate and p-cresyl sulfate) were studied by molecular dynamics (MD) simulations and umbrella sampling. For the NU series of MOFs, good correlations between the Gibbs free energy (ΔG) and the experimental clearance rates of PBUTs are found. For the adsorption behaviors, in terms of ΔG, DAJWET exhibits the best adsorption effect for indoxyl sulfate (IS), whereas NU-1000 shows the best effect for p-cresyl sulfate (pCS). Similar trends observed in the radial distribution function and mean square displacement results suggest that the π-π stacking interactions play a crucial role in the adsorption and diffusion of PBUTs by MOFs. Furthermore, it can be concluded that MOFs with highly conjugated groups (porphyrin rings and pyrene groups) tend to generate more PBUT attraction, and provide design principles for potential MOF candidates in the removal of PBUTs.
Collapse
Affiliation(s)
- Junyi Hou
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Mengjie Liu
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Weiqun Gao
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Kexin Yan
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Bihong Li
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Weizhong Zheng
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Shaomin Gong
- Department of Nephrology, Zhongshan Hospital of Fudan University, Shanghai 200032, China
| | - Xiaoyan Zhang
- Department of Nephrology, Zhongshan Hospital of Fudan University, Shanghai 200032, China
| | - Weizhen Sun
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China
| |
Collapse
|
3
|
Deng LE, Guo M, Deng Y, Pan Y, Wang X, Maduraiveeran G, Liu J, Lu C. MOF-Based Platform for Kidney Diseases: Advances, Challenges, and Prospects. Pharmaceutics 2024; 16:793. [PMID: 38931914 PMCID: PMC11207304 DOI: 10.3390/pharmaceutics16060793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 06/03/2024] [Accepted: 06/04/2024] [Indexed: 06/28/2024] Open
Abstract
Kidney diseases are important diseases that affect human health worldwide. According to the 2020 World Health Organization (WHO) report, kidney diseases have become the top 10 causes of death. Strengthening the prevention, primary diagnosis, and action of kidney-related diseases is of great significance in maintaining human health and improving the quality of life. It is increasingly challenging to address clinical needs with the present technologies for diagnosing and treating renal illness. Fortunately, metal-organic frameworks (MOFs) have shown great promise in the diagnosis and treatment of kidney diseases. This review summarizes the research progress of MOFs in the diagnosis and treatment of renal disease in recent years. Firstly, we introduce the basic structure and properties of MOFs. Secondly, we focus on the utilization of MOFs in the diagnosis and treatment of kidney diseases. In the diagnosis of kidney disease, MOFs are usually designed as biosensors to detect biomarkers related to kidney disease. In the treatment of kidney disease, MOFs can not only be used as an effective adsorbent for uremic toxins during hemodialysis but also as a precise treatment of intelligent drug delivery carriers. They can also be combined with nano-chelation technology to solve the problem of the imbalance of trace elements in kidney disease. Finally, we describe the current challenges and prospects of MOFs in the diagnosis and treatment of kidney diseases.
Collapse
Affiliation(s)
- Li-Er Deng
- Department of Nephrology, Dongguan Traditional Chinese Medicine Hospital, Dongguan 523000, China
| | - Manli Guo
- Dongguan Key Laboratory of Drug Design and Formulation Technology, Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, Guangdong Medical University, Dongguan 523808, China
| | - Yijun Deng
- Dongguan Key Laboratory of Drug Design and Formulation Technology, Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, Guangdong Medical University, Dongguan 523808, China
| | - Ying Pan
- Dongguan Key Laboratory of Drug Design and Formulation Technology, Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, Guangdong Medical University, Dongguan 523808, China
| | - Xiaoxiong Wang
- School of Materials and Environmental Engineering, Shenzhen Polytechnic University, Shenzhen 518055, China
| | - Govindhan Maduraiveeran
- Materials Electrochemistry Laboratory, Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603 203, Tamil Nadu, India;
| | - Jianqiang Liu
- Dongguan Key Laboratory of Drug Design and Formulation Technology, Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, Guangdong Medical University, Dongguan 523808, China
| | - Chengyu Lu
- Dongguan Key Laboratory of Drug Design and Formulation Technology, Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, Guangdong Medical University, Dongguan 523808, China
| |
Collapse
|
4
|
Kooman JP. The Revival of Sorbents in Chronic Dialysis Treatment. Semin Dial 2024. [PMID: 38506130 DOI: 10.1111/sdi.13203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Accepted: 02/04/2024] [Indexed: 03/21/2024]
Abstract
Interest in the use of sorbents in chronic dialysis treatment has undergone a revival in the last decades, for which two major factors are responsible. The first is the potential of sorbents as adjunct therapy for the removal of substances that are difficult to remove by conventional dialysis therapies. The second is their use in regeneration of dialysate, which is of pivotal importance in the design of portable or even wearable treatments, next to the potential for reducing water use during conventional dialysis treatment. Sorbent-enhanced dialysis with synthetic polymers was associated with a reduction in inflammatory parameters as compared to hemodialysis and even associated with improved survival in smaller studies, although this needs to be confirmed in large randomized trials. Incorporation of sorbents within a dialysis membrane (mixed matrix membrane) appears a promising way forward to reduce the complexity and costs of a dual therapy but needs to be tested in vivo. For regeneration of dialysate, at present, a combination of urease, zirconium-based sorbents, and activated charcoal is used. Next to sodium release by the sorbent in exchange for ammonium and the CO2 release by the hydrolysis of urea has been a bottleneck in the design of wearable devices, although short-term trials have been performed. Still, for widespread and flexible application of sorbent-assisted portable or wearable devices, a direct urea sorbent would be a major asset. In the near future, it will likely become apparent whether sorbent-assisted dialysis techniques are feasible for routine implementation in clinical practice.
Collapse
Affiliation(s)
- Jeroen Peter Kooman
- Division of Nephrology, Department of Internal Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands
| |
Collapse
|
5
|
Rodrigues FSC, Brilhante D, Macêdo A, Pires RF, Faria M. Ibuprofen-Immobilized Thin Films: A Novel Approach to Improve the Clearance of Protein-Bound Uremic Toxins. ACS APPLIED MATERIALS & INTERFACES 2024; 16:6589-6604. [PMID: 38282580 DOI: 10.1021/acsami.3c15291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2024]
Abstract
Chronic kidney disease (CKD), a pressing global health issue, affects millions and leads to end-stage renal disease (ESRD). Hemodialysis (HD) is a crucial treatment for ESRD, yet its limited efficiency in removing protein-bound uremic toxins (PBUTs) results in high morbidity and mortality rates. A high affinity of pharmaceutical drugs for human serum albumin (HSA) can be leveraged to compete effectively with PBUTs for the same HSA binding sites, thereby enabling them to be capable of displacing these toxins. One such drug is ibuprofen (IBF), known for its very high affinity for HSA and sharing the same binding site as indoxyl sulfate (IS). This study explores the development of IBF-immobilized cellulose acetate-based (CA-based) thin films. The films were created by reacting CA with IBF-modified silica precursors at varying concentrations. The presence of IBF in CA/TEOS/APTES-IBF-3 and CA/TEOS-IBF-25 films, containing 3 and 25 wt % IBF, respectively, was confirmed through 1H NMR spectra. Competitive displacement binding assays indicated that while the incorporation of 3 wt % IBF showed no significant enhancement in IS displacement, the 25 wt % IBF film increased the dialyzed IS by 1.3 when normalized to non-IBF films. Furthermore, there was a 1.2-fold decrease in the total percentage of IS, and the free percentage of IS increased 1.3 to 3.0 times. Although direct systemic infusion of IBF in HD patients achieves a 2.4 times higher removal of IS, it is impractical due to the risks it poses to ESRD patients. The IBF-immobilized films offer the advantage of localized binding, thus eliminating the need for systemic exposure. This innovative approach lays a foundation for developing more efficient HD membranes, aiming to address the challenging issue of PBUT elimination and potentially enhance the quality of life and treatment outcomes for ESRD patients.
Collapse
Affiliation(s)
- Flávia S C Rodrigues
- Laboratory of Physics of Materials and Emerging Technologies (LaPMET), Center of Physics and Engineering of Advanced Materials (CeFEMA), Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal
| | - Dialina Brilhante
- Serviço de Imunohemoterapia, Instituto Português de Oncologia de Lisboa Francisco Gentil (IPO Lisboa), R. Prof. Lima Basto, 1099-023 Lisbon, Portugal
| | - Ana Macêdo
- Serviço de Imunohemoterapia, Instituto Português de Oncologia de Lisboa Francisco Gentil (IPO Lisboa), R. Prof. Lima Basto, 1099-023 Lisbon, Portugal
| | - Rita F Pires
- Laboratory of Physics of Materials and Emerging Technologies (LaPMET), Center of Physics and Engineering of Advanced Materials (CeFEMA), Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal
| | - Mónica Faria
- Laboratory of Physics of Materials and Emerging Technologies (LaPMET), Center of Physics and Engineering of Advanced Materials (CeFEMA), Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal
| |
Collapse
|
6
|
Álvarez-Merino MA, Carrasco-Marín F, Warren-Vega WM, Romero-Cano LA. Artificial intelligence application in adsorption of uremic toxins: Towards the eco-friendly design of highly efficient with potential applications as hemodialysis membranes. ENVIRONMENTAL RESEARCH 2024; 241:117671. [PMID: 37984789 DOI: 10.1016/j.envres.2023.117671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 10/31/2023] [Accepted: 11/13/2023] [Indexed: 11/22/2023]
Abstract
Six Functionalized Activated Carbon Cloths (FACCs) were designed to obtain fundamental information for training a Bayesian Regularized Artificial Neural Network (BRANN) capable of predicting adsorption capacity of the FACCs to synthesize tailor-made materials with potential application as dialysis membranes. Characterization studies showed that FACCs have a high surface area (1354-2073 m2 g-1) associated with increased microporosity (W0, average: 0.57 cm3 g-1). Materials are carbonaceous, with a carbon content between 69 and 92%. Chemical treatments modify the pHpzc of materials between 4.1 and 7.8 due to incorporating functional groups on the surface (C=O, -COOH, -OH, -NH, -NH2). Uremic toxins tests showed a high elimination rate of p-cresol (73 mg g-1) and creatinine (90 mg g-1) which is not affected by the matrix (aqueous solution and simulated serum). However, in the case of uric acid, adsorption capacity decreased from 143 mg g-1 to 71 mg g-1, respectively. When comparing the kinetic constants of the adsorption studies in simulated serum versus the studies in aqueous solution, it can be seen that this does not undergo significant changes (0.02 min-1), evidencing the versatility of the material to work in different matrices. The previous studies, in combination with characterization of the materials, allowed to establish the adsorption mechanism. Thus, it permitted to train the BRANN to obtain mathematical models capable to predict the kinetic adsorption of the toxins studied. It is concluded that the predominant adsorption mechanism is due to π-π interactions between the adsorbate unsaturations with the material's pseudo-graphitic planes. Results show that FACCs are promising materials for hemodialysis membranes. Finally, taking into consideration the adsorption capacities and rates, as well as the semiquantitative analysis of the environmental impact associated with the preparation of the adsorbents, the best adsorbent (CC, Eco-Scale = 91.5) was selected. The studies presented show that the material is eco-friendly and highly efficient in the elimination of uremic toxins.
Collapse
Affiliation(s)
- Miguel A Álvarez-Merino
- Departamento de Química Inorgánica y Orgánica, Facultad de Ciencias Experimentales, Universidad de Jaén, 23071, Jaén, Spain.
| | - Francisco Carrasco-Marín
- Materiales Polifuncionales Basados en Carbono (UGR-Carbon), Departamento de Química Inorgánica, Facultad de Ciencias - Unidad de Excelencia Química Aplicada a Biomedicina y Medioambiente - Universidad de Granada (UEQ-UGR), 18071, Granada, Spain
| | - Walter M Warren-Vega
- Grupo de Investigación en Materiales y Fenómenos de Superficie, Facultad de Ciencias Químicas, Universidad Autónoma de Guadalajara, Av. Patria 1201, C.P. 45129, Zapopan, Jalisco, Mexico
| | - Luis A Romero-Cano
- Grupo de Investigación en Materiales y Fenómenos de Superficie, Facultad de Ciencias Químicas, Universidad Autónoma de Guadalajara, Av. Patria 1201, C.P. 45129, Zapopan, Jalisco, Mexico.
| |
Collapse
|
7
|
Sun J, Pang H, Chen L. Organic-Solvent-Resistant Polyimide/Hydroxyapatite Mixed Matrix Membranes for Lysozyme Adsorption. MATERIALS (BASEL, SWITZERLAND) 2023; 16:7210. [PMID: 38005139 PMCID: PMC10672861 DOI: 10.3390/ma16227210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 11/12/2023] [Accepted: 11/14/2023] [Indexed: 11/26/2023]
Abstract
This work reports new mixed matrix membranes (MMMs) for the adsorption of enzymes from organic solvents. In this work, polyimide/hydroxyapatite (PI/HAP) MMMs were prepared via phase inversion method and further crosslinked with 3-aminopropyl triethoxysilane (APTES). The chemical and structural stability of the crosslinked PI/HAP MMMs were improved and applied for lysozyme (LZ) adsorption in organic solvent. PI/HAP MMMs were crosslinked by changing the 3-aminopropyltriethoxysilane (APTES) concentration and crosslinking time. The optimal APTES crosslinking condition for PI/HAP MMMs is 6% of concentration for 8 h. The LZ adsorption performance was studied by changing solvent types. PI/HAP MMMs possessed a high LZ adsorption in organic-solvent-aqueous solutions, and the LZ adsorption capacity reached 34.1 mg/g. The MMMs had a high desorption capacity and recovery ability. The MMMs maintained 60% of their adsorption capacity and 58% of their desorption at the fourth cycle of adsorption and desorption. The MMMs provided a new technology for the purification and separation of enzymes or proteins by MMMs in organic solvents.
Collapse
Affiliation(s)
- Junfen Sun
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Material Science and Engineering, Donghua University, North People Road 2999, Shanghai 201620, China;
| | | | - Long Chen
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Material Science and Engineering, Donghua University, North People Road 2999, Shanghai 201620, China;
| |
Collapse
|
8
|
Ahmed S, de Vries JC, Lu J, Stuart MHV, Mihăilă SM, Vernooij RWM, Masereeuw R, Gerritsen KGF. Animal Models for Studying Protein-Bound Uremic Toxin Removal-A Systematic Review. Int J Mol Sci 2023; 24:13197. [PMID: 37686004 PMCID: PMC10487432 DOI: 10.3390/ijms241713197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 08/18/2023] [Accepted: 08/23/2023] [Indexed: 09/10/2023] Open
Abstract
Protein-bound uremic toxins (PBUTs) are associated with the progression of chronic kidney disease (CKD) and its associated morbidity and mortality. The conventional dialysis techniques are unable to efficiently remove PBUTs due to their plasma protein binding. Therefore, novel approaches are being developed, but these require validation in animals before clinical trials can begin. We conducted a systematic review to document PBUT concentrations in various models and species. The search strategy returned 1163 results for which abstracts were screened, resulting in 65 full-text papers for data extraction (rats (n = 41), mice (n = 17), dogs (n = 3), cats (n = 4), goats (n = 1), and pigs (n = 1)). We performed descriptive and comparative analyses on indoxyl sulfate (IS) concentrations in rats and mice. The data on large animals and on other PBUTs were too heterogeneous for pooled analysis. Most rodent studies reported mean uremic concentrations of plasma IS close to or within the range of those during kidney failure in humans, with the highest in tubular injury models in rats. Compared to nephron loss models in rats, a greater rise in plasma IS compared to creatinine was found in tubular injury models, suggesting tubular secretion was more affected than glomerular filtration. In summary, tubular injury rat models may be most relevant for the in vivo validation of novel PBUT-lowering strategies for kidney failure in humans.
Collapse
Affiliation(s)
- Sabbir Ahmed
- Division of Pharmacology, Utrecht Institute for Pharmaceutical Sciences, Universiteitsweg 99, 3584 CG Utrecht, The Netherlands; (S.A.); (J.L.); (S.M.M.); (R.M.)
| | - Joost C. de Vries
- Department of Nephrology and Hypertension, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands; (J.C.d.V.); (M.H.V.S.); (R.W.M.V.)
| | - Jingyi Lu
- Division of Pharmacology, Utrecht Institute for Pharmaceutical Sciences, Universiteitsweg 99, 3584 CG Utrecht, The Netherlands; (S.A.); (J.L.); (S.M.M.); (R.M.)
| | - Milan H. Verrijn Stuart
- Department of Nephrology and Hypertension, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands; (J.C.d.V.); (M.H.V.S.); (R.W.M.V.)
| | - Silvia M. Mihăilă
- Division of Pharmacology, Utrecht Institute for Pharmaceutical Sciences, Universiteitsweg 99, 3584 CG Utrecht, The Netherlands; (S.A.); (J.L.); (S.M.M.); (R.M.)
| | - Robin W. M. Vernooij
- Department of Nephrology and Hypertension, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands; (J.C.d.V.); (M.H.V.S.); (R.W.M.V.)
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, 3584 CX Utrecht, The Netherlands
| | - Rosalinde Masereeuw
- Division of Pharmacology, Utrecht Institute for Pharmaceutical Sciences, Universiteitsweg 99, 3584 CG Utrecht, The Netherlands; (S.A.); (J.L.); (S.M.M.); (R.M.)
| | - Karin G. F. Gerritsen
- Department of Nephrology and Hypertension, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands; (J.C.d.V.); (M.H.V.S.); (R.W.M.V.)
| |
Collapse
|
9
|
Ramada DL, de Vries J, Vollenbroek J, Noor N, Ter Beek O, Mihăilă SM, Wieringa F, Masereeuw R, Gerritsen K, Stamatialis D. Portable, wearable and implantable artificial kidney systems: needs, opportunities and challenges. Nat Rev Nephrol 2023:10.1038/s41581-023-00726-9. [PMID: 37277461 DOI: 10.1038/s41581-023-00726-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/28/2023] [Indexed: 06/07/2023]
Abstract
Haemodialysis is life sustaining but expensive, provides limited removal of uraemic solutes, is associated with poor patient quality of life and has a large carbon footprint. Innovative dialysis technologies such as portable, wearable and implantable artificial kidney systems are being developed with the aim of addressing these issues and improving patient care. An important challenge for these technologies is the need for continuous regeneration of a small volume of dialysate. Dialysate recycling systems based on sorbents have great potential for such regeneration. Novel dialysis membranes composed of polymeric or inorganic materials are being developed to improve the removal of a broad range of uraemic toxins, with low levels of membrane fouling compared with currently available synthetic membranes. To achieve more complete therapy and provide important biological functions, these novel membranes could be combined with bioartificial kidneys, which consist of artificial membranes combined with kidney cells. Implementation of these systems will require robust cell sourcing; cell culture facilities annexed to dialysis centres; large-scale, low-cost production; and quality control measures. These challenges are not trivial, and global initiatives involving all relevant stakeholders, including academics, industrialists, medical professionals and patients with kidney disease, are required to achieve important technological breakthroughs.
Collapse
Affiliation(s)
- David Loureiro Ramada
- Advanced Organ bioengineering and Therapeutics, Faculty of Science and Technology, Technical Medical Centre, University of Twente, P.O Box 217, 7500, AE Enschede, The Netherlands
| | - Joost de Vries
- Department of Nephrology and Hypertension, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Jeroen Vollenbroek
- Department of Nephrology and Hypertension, University Medical Center Utrecht, Utrecht, The Netherlands
- BIOS Lab on a Chip Group, MESA + Institute, University of Twente, Hallenweg 15, 7522, NH Enschede, The Netherlands
| | - Nazia Noor
- Advanced Organ bioengineering and Therapeutics, Faculty of Science and Technology, Technical Medical Centre, University of Twente, P.O Box 217, 7500, AE Enschede, The Netherlands
| | - Odyl Ter Beek
- Advanced Organ bioengineering and Therapeutics, Faculty of Science and Technology, Technical Medical Centre, University of Twente, P.O Box 217, 7500, AE Enschede, The Netherlands
| | - Silvia M Mihăilă
- Division of Pharmacology, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands
| | - Fokko Wieringa
- Department of Nephrology and Hypertension, University Medical Center Utrecht, Utrecht, The Netherlands
- Department of Autonomous Therapeutics, IMEC, Eindhoven, The Netherlands
- European Kidney Health Alliance (EKHA), WG3 "Breakthrough Innovation", Brussels, Belgium
| | - Rosalinde Masereeuw
- Division of Pharmacology, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands
| | - Karin Gerritsen
- Department of Nephrology and Hypertension, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Dimitrios Stamatialis
- Advanced Organ bioengineering and Therapeutics, Faculty of Science and Technology, Technical Medical Centre, University of Twente, P.O Box 217, 7500, AE Enschede, The Netherlands.
- European Kidney Health Alliance (EKHA), WG3 "Breakthrough Innovation", Brussels, Belgium.
| |
Collapse
|
10
|
Adsorption- and Displacement-Based Approaches for the Removal of Protein-Bound Uremic Toxins. Toxins (Basel) 2023; 15:toxins15020110. [PMID: 36828424 PMCID: PMC9963700 DOI: 10.3390/toxins15020110] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/23/2023] [Accepted: 01/26/2023] [Indexed: 01/31/2023] Open
Abstract
End-stage renal disease (ESRD) patients rely on renal replacement therapies to survive. Hemodialysis (HD), the most widely applied treatment, is responsible for the removal of excess fluid and uremic toxins (UTs) from blood, particularly those with low molecular weight (MW < 500 Da). The development of high-flux membranes and more efficient treatment modes, such as hemodiafiltration, have resulted in improved removal rates of UTs in the middle molecular weight range. However, the concentrations of protein-bound uremic toxins (PBUTs) remain essentially untouched. Due to the high binding affinity to large proteins, such as albumin, PBUTs form large complexes (MW > 66 kDa) which are not removed during HD and their accumulation has been strongly associated with the increased morbidity and mortality of patients with ESRD. In this review, we describe adsorption- and displacement-based approaches currently being studied to enhance the removal of PBUTs. The development of mixed matrix membranes (MMMs) with selective adsorption properties, infusion of compounds capable of displacing UTs from their binding site on albumin, and competitive binding membranes show promising results, but the road to clinical application is still long, and further investigation is required.
Collapse
|
11
|
Raharjo Y, Ismail AF, Dzarfan Othman MH, Fahmi MZ, Saiful, Santoso D, Nugroho MI, Merna D, Arief MD, Pratama RC. Selectively mixed matrix hemodialysis membrane for adequate clearance of p-cresol by the incorporation of imprinted zeolite. RSC Adv 2023; 13:2972-2983. [PMID: 36756405 PMCID: PMC9850457 DOI: 10.1039/d2ra07557a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Accepted: 01/03/2023] [Indexed: 01/20/2023] Open
Abstract
The adequacy in uremic toxin removal upon hemodialysis treatment is essential in patients with kidney failure diseases as poor removal leads to heart failure, hypertension, and stroke. The combination of adsorption and diffusion processes has become very advantageous for hemodialysis membranes. By this mechanism, water-soluble uremic toxins (WSUTs) and protein-bounded uremic toxins (PBUTs) could be removed at one time. Therefore, this study aimed to develop a novel imprinted zeolite by p-cresol (IZC) and then incorporated it into polyethersulfone (PES) and poly(vinyl pyrrolidone) (PVP) to produce hollow fiber mixed matrix membrane (HF-MMM). The IZC proved to be sensitive in attracting the adsorbate, classifying it as having a strong adsorption behavior. Accordingly, IZC is very promising to be applied as an adsorbent in the hemodialysis treatment. In this study, IZC as p-cresol's adsorbent was incorporated into a PES-based polymeric membrane with a small addition of PVP to produce HF-MMM using a dry/wet spinning process. The effect of air gap distance between the spinneret and coagulant bath and percentage loading for PES, PVP, and IZC were studied and optimized to obtain the best performance of HF-MMM. The 40 cm of air gap distance, 16 wt% of PES, 2 wt% of PVP, and 1 wt% of IZC loading were able to produce a superior hemodialysis membrane. These optimized parameters showed sufficient uremic toxin removal, i.e., 60.74% of urea, 52.35% of p-cresol in the phosphate buffer saline solution, and 66.29% of p-cresol in bovine serum albumin solution for 4 h permeation using the dialysis system. These HF-MMMs also achieved pure water flux of 67.57 L m-2 h-1 bar-1 and bovine serum albumin rejection of 95.05%. Therefore, this membrane has proven to be able to clean up WSUT and PBUT through a one-step process. Moreover, as compared to the neat PES membrane, MMM was able to remove p-cresol at 186.22 times higher capability.
Collapse
Affiliation(s)
- Yanuardi Raharjo
- Membrane Science and Technology Research Group (MSTRG), Chemistry Department, Faculty of Science and Technology, Universitas Airlangga Surabaya 60115 Indonesia
| | - Ahmad Fauzi Ismail
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi MalaysiaSkudai 81310Malaysia
| | - Mohd Hafiz Dzarfan Othman
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi MalaysiaSkudai 81310Malaysia
| | - Mochamad Zakki Fahmi
- Membrane Science and Technology Research Group (MSTRG), Chemistry Department, Faculty of Science and Technology, Universitas Airlangga Surabaya 60115 Indonesia
| | - Saiful
- Chemistry Department, Faculty of Mathematics and Natural Science, Universitas Syiah KualaBanda AcehIndonesia
| | - Djoko Santoso
- Division of Nephrology and Hypertension, Dr Soetomo Hospital, Faculty of Medicine, Universitas AirlanggaSurabaya 60115Indonesia
| | - Mochamad Ifan Nugroho
- Membrane Science and Technology Research Group (MSTRG), Chemistry Department, Faculty of Science and Technology, Universitas Airlangga Surabaya 60115 Indonesia
| | - Diana Merna
- Membrane Science and Technology Research Group (MSTRG), Chemistry Department, Faculty of Science and Technology, Universitas Airlangga Surabaya 60115 Indonesia
| | - Maipha Deapati Arief
- Membrane Science and Technology Research Group (MSTRG), Chemistry Department, Faculty of Science and Technology, Universitas Airlangga Surabaya 60115 Indonesia
| | - Risma Chikita Pratama
- Membrane Science and Technology Research Group (MSTRG), Chemistry Department, Faculty of Science and Technology, Universitas Airlangga Surabaya 60115 Indonesia
| |
Collapse
|
12
|
Zhang M, Li L, Lei L, Kang K, Xiao C. Effectively Decontaminating Protein-Bound Uremic Toxins in Human Serum Albumin Using Cationic Metal-Organic Frameworks. ACS APPLIED MATERIALS & INTERFACES 2022; 14:55354-55364. [PMID: 36484258 DOI: 10.1021/acsami.2c15864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
In the field of replacement of conventional dialysis treatment, searching superior materials for removal of protein-bound uremic toxins is a challenge on account of strong interactions between proteins and uremic toxins. Herein, we first adopted cationic metal-organic frameworks (MOFs), ZJU-X6 and ZJU-X7, as sorbents to decontaminate uremic toxins (p-cresyl sulfate and indoxyl sulfate). ZJU-X6 and ZJU-X7 exhibited innate advantage for sequestration of uremic toxins by utilizing a positive charge framework with exchangeable anions. Especially, ZJU-X6 showed a higher sorption capacity and faster sorption kinetics than those of most reported materials. Moreover, the cationic MOF materials could selectively remove uremic toxins even if in the presence of competitive chloride ions and proteins. Meanwhile, pair distribution function (PDF) and density functional theory (DFT) were employed to elucidate the sorption mechanism between uremic toxins and sorbents. This work suggests an attractive avenue for constructing new types of sorbents to eliminate uremic toxins for uremia treatment.
Collapse
Affiliation(s)
- Meiyu Zhang
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou310027, China
| | - Lei Li
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou310027, China
| | - Lecheng Lei
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou310027, China
| | - Kang Kang
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou310027, China
| | - Chengliang Xiao
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou310027, China
- Institute of Zhejiang University─Quzhou, 78 Jiuhua Boulevard North, Quzhou324000, China
| |
Collapse
|
13
|
Ding W, Ding S, Meng Z, Wang X. Hierarchically structural polyacrylonitrile/
MIL
‐101(Cr) nanofibrous membranes with super adsorption performance for indoxyl sulfate. J Appl Polym Sci 2022. [DOI: 10.1002/app.53399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- Weihong Ding
- State Key Lab for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering Donghua University Shanghai China
| | - Siping Ding
- State Key Lab for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering Donghua University Shanghai China
| | - Zheyi Meng
- State Key Lab for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering Donghua University Shanghai China
| | - Xuefen Wang
- State Key Lab for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering Donghua University Shanghai China
| |
Collapse
|
14
|
Ding S, Wang D, Wang X. Hierarchically structural layered double oxides with stretchable nanopores for highly effective removal of protein-bound uremic toxins. Sep Purif Technol 2022; 301:122033. [PMID: 36071792 PMCID: PMC9436783 DOI: 10.1016/j.seppur.2022.122033] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Revised: 08/08/2022] [Accepted: 08/26/2022] [Indexed: 12/02/2022]
Abstract
The global outbreak and prevalence of coronavirus disease 2019 (COVID-19) has triggered an urgent demand for family hemodialysis equipment. It is particularly vital to design and apply superior adsorbents to adsorb toxins for reducing the usage of dialysate. In this work, hierarchically structural MgAl layered double oxides (LDO) with stretchable nanopores were exploited through a facile one-pot trisodium citrate (TSC) assistant hydrothermal reaction followed by calcination treatment for effectively adsorbing protein-bound uremic toxins such as hippuric acid (HA) or indoxyl sulfate (IS). The optimized MgAl LDO possessed flower-like spherical morphology, ultrahigh specific surface area (187.3 m2/g) and uniquely stretchable nanopores, which were more conducive to incorporating anions due to their unique memory effect endowing them with promising adsorption capacities for HA or IS. And the adsorption data could be better conformed to pseudo-second-order kinetic model and Langmuir isotherm determining that the maximum adsorption capacity of HA and IS was 129.8 mg/g and 63.1 mg/g, respectively. Furthermore, the computation of molecular size paired with the analysis of adsorption mechanism accurately revealed that high-efficiency toxin capture was mainly attributed to electrostatic interaction for internal intercalation and surface adsorption. Therefore, the application of such delicate LDO as new premium adsorbent would facilitate the development and popularization of family hemodialysis equipment.
Collapse
Affiliation(s)
- Siping Ding
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, PR China
| | - Dong Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, PR China
| | - Xuefen Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, PR China
| |
Collapse
|
15
|
Zawada AM, Lang T, Ottillinger B, Kircelli F, Stauss-Grabo M, Kennedy JP. Impact of Hydrophilic Modification of Synthetic Dialysis Membranes on Hemocompatibility and Performance. MEMBRANES 2022; 12:932. [PMID: 36295691 PMCID: PMC9610916 DOI: 10.3390/membranes12100932] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 09/16/2022] [Accepted: 09/21/2022] [Indexed: 06/16/2023]
Abstract
The dialyzer is the core element in the hemodialysis treatment of patients with end-stage kidney disease (ESKD). During hemodialysis treatment, the dialyzer replaces the function of the kidney by removing small and middle-molecular weight uremic toxins, while retaining essential proteins. Meanwhile, a dialyzer should have the best possible hemocompatibility profile as the perpetuated contact of blood with artificial surfaces triggers complement activation, coagulation and immune cell activation, and even low-level activation repeated chronically over years may lead to undesired effects. During hemodialysis, the adsorption of plasma proteins to the dialyzer membrane leads to a formation of a secondary membrane, which can compromise both the uremic toxin removal and hemocompatibility of the dialyzer. Hydrophilic modifications of novel dialysis membranes have been shown to reduce protein adsorption, leading to better hemocompatibility profile and performance stability during dialysis treatments. This review article focuses on the importance of performance and hemocompatibility of dialysis membranes for the treatment of dialysis patients and summarizes recent studies on the impact of protein adsorption and hydrophilic modifications of membranes on these two core elements of a dialyzer.
Collapse
Affiliation(s)
- Adam M. Zawada
- Product Development, Fresenius Medical Care Deutschland GmbH, 66606 Sankt Wendel, Germany
| | - Thomas Lang
- Global Biomedical Evidence Generation, Fresenius Medical Care Deutschland GmbH, 61352 Bad Homburg, Germany
| | | | - Fatih Kircelli
- Medical Information and Education (EMEA), Fresenius Medical Care Deutschland GmbH, 61352 Bad Homburg, Germany
| | - Manuela Stauss-Grabo
- Global Biomedical Evidence Generation, Fresenius Medical Care Deutschland GmbH, 61352 Bad Homburg, Germany
| | - James P. Kennedy
- Product Development, Fresenius Medical Care Deutschland GmbH, 66606 Sankt Wendel, Germany
| |
Collapse
|
16
|
Yao X, Liu Y, Chu Z, Jin W. Membranes for the life sciences and their future roles in medicine. Chin J Chem Eng 2022; 49:1-20. [PMID: 35755178 PMCID: PMC9212902 DOI: 10.1016/j.cjche.2022.04.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 04/15/2022] [Accepted: 04/15/2022] [Indexed: 01/12/2023]
Abstract
Since the global outbreak of COVID-19, membrane technology for clinical treatments, including extracorporeal membrane oxygenation (ECMO) and protective masks and clothing, has attracted intense research attention for its irreplaceable abilities. Membrane research and applications are now playing an increasingly important role in various fields of life science. In addition to intrinsic properties such as size sieving, dissolution and diffusion, membranes are often endowed with additional functions as cell scaffolds, catalysts or sensors to satisfy the specific requirements of different clinical applications. In this review, we will introduce and discuss state-of-the-art membranes and their respective functions in four typical areas of life science: artificial organs, tissue engineering, in vitro blood diagnosis and medical support. Emphasis will be given to the description of certain specific functions required of membranes in each field to provide guidance for the selection and fabrication of the membrane material. The advantages and disadvantages of these membranes have been compared to indicate further development directions for different clinical applications. Finally, we propose challenges and outlooks for future development.
Collapse
Affiliation(s)
- Xiaoyue Yao
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Yu Liu
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Zhenyu Chu
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Wanqin Jin
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China
| |
Collapse
|
17
|
Li W, Li Y, Wen X, Teng Y, Wang J, Yang T, Li X, Li L, Wang C. Flexible Zr-MOF anchored polymer nanofiber membrane for efficient removal of creatinine in uremic toxins. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2022.120369] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
18
|
Dialysis Membranes for Acute Kidney Injury. MEMBRANES 2022; 12:membranes12030325. [PMID: 35323800 PMCID: PMC8949515 DOI: 10.3390/membranes12030325] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 03/06/2022] [Accepted: 03/07/2022] [Indexed: 11/25/2022]
Abstract
Mortality and morbidity rates among critically ill septic patients having acute kidney injury (AKI) are very high, considering the total number of deaths after their admission. Inappropriate selection of the type of continuous renal replacement therapy and inadequate therapy become the immediate causes of these issues. Dialysis is a commonly used treatment intended to prolong the life of AKI patients. Dialysis membranes, which are the core of dialysis treatment, must be properly selected to ensure fair treatment to the patients. The accumulation of certain types of molecules must be dealt with using the right membrane. Whether it is low-flux, high-flux, or adsorptive type, the dialysis membrane should be chosen depending on the condition of the patients. The selection of dialysis membranes should also be based on their effect on the treatment outcomes and well-being. All these options are needed to serve the patients of different clinical settings. The use of dialysis membranes is not restricted to conventional haemodialysis, but rather they can be employed in haemoperfusion, haemofiltration, haemodiafiltration, or a combination of any two of them. This review focuses in-depth on different types of dialysis membranes, their characteristics, and approaches in addressing the issues encountered in patients having AKI with sepsis and/or multiorgan failure in intensive care units.
Collapse
|
19
|
De Pascale M, De Angelis MG, Boi C. Mixed Matrix Membranes Adsorbers (MMMAs) for the Removal of Uremic Toxins from Dialysate. MEMBRANES 2022; 12:203. [PMID: 35207125 PMCID: PMC8878186 DOI: 10.3390/membranes12020203] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 01/21/2022] [Accepted: 02/01/2022] [Indexed: 02/01/2023]
Abstract
We developed Mixed Matrix Membrane Adsorbers (MMMAs) formed by cellulose acetate and various sorbent particles (activated carbon, zeolites ZSM-5 and clinoptilolite) for the removal of urea, creatinine and uric acid from aqueous solutions, to be used in the regeneration of spent dialysate water from Hemodialysis (HD). This process would allow reducing the disproportionate amount of water consumed and permits the development of closed-loop HD devices, such as wearable artificial kidneys. The strategy of MMMAs is to combine the high permeability of porous membranes with the toxin-capturing ability of embedded particles. The water permeability of the MMMAs ranges between 600 and 1500 L/(h m2 bar). The adsorption of urea, the limiting toxin, can be improved of about nine times with respect to the pure cellulose acetate membrane. Flow experiments demonstrate the feasibility of the process in a real HD therapy session.
Collapse
Affiliation(s)
- Matilde De Pascale
- Department of Civil, Chemical Environmental and Materials Engineering, DICAM, University of Bologna, Via Terracini 28, 40131 Bologna, Italy;
| | - Maria Grazia De Angelis
- Department of Civil, Chemical Environmental and Materials Engineering, DICAM, University of Bologna, Via Terracini 28, 40131 Bologna, Italy;
- Institute for Materials and Processes, School of Engineering, University of Edinburgh, Sanderson Building, Robert Stevenson Road, Edinburgh EH9 3FB, UK
- Italian Consortium for Science and Technology of Materials (INSTM), 50121 Firenze, Italy
| | - Cristiana Boi
- Department of Civil, Chemical Environmental and Materials Engineering, DICAM, University of Bologna, Via Terracini 28, 40131 Bologna, Italy;
| |
Collapse
|
20
|
Gao C, Zhang Q, Yang Y, Li Y, Lin W. Recent trends in therapeutic application of engineered blood purification materials for kidney disease. Biomater Res 2022; 26:5. [PMID: 35120554 PMCID: PMC8815201 DOI: 10.1186/s40824-022-00250-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Accepted: 01/10/2022] [Indexed: 12/11/2022] Open
Abstract
Blood purification is a commonly used method to remove excess metabolic waste in the blood in renal replacement therapy. The sufficient removal of these toxins from blood can reduce complications and improve survival lifetime in dialysis patients. However, the current biological blood purification materials in clinical practice are not ideal, where there is an unmet need for producing novel materials that have better biocompatibility, reduced toxicity, and, in particular, more efficient toxin clearance rates and a lower cost of production. Given this, this review has carefully summarized newly developed engineered different structural biomedical materials for blood purification in terms of types and structure characteristics of blood purification materials, the production process, as well as interfacial chemical adsorption properties or mechanisms. This study may provide a valuable reference for fabricating a user-friendly purification device that is more suitable for clinical blood purification applications in dialysis patients.
Collapse
Affiliation(s)
- Cui Gao
- Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, Zhejiang, China
| | - Qian Zhang
- Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, Zhejiang, China
| | - Yi Yang
- Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, Zhejiang, China.
- Department of Nephology, The Fourth Affiliated Hospital, Zhejiang University School of Medicine, Yiwu, 322000, Zhejiang, China.
- International Institutes of Medicine, The Fourth Affiliated Hospital, Zhejiang University School of Medicine, Yiwu, 322000, Zhejiang, China.
| | - Yangyang Li
- Key Laboratory of Women's Reproductive Health Research of Zhejiang Province, Women's Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, Zhejiang, China.
- Cancer Center, Zhejiang University, Hangzhou, 310058, Zhejiang, China.
| | - Weiqiang Lin
- Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, Zhejiang, China.
- International Institutes of Medicine, The Fourth Affiliated Hospital, Zhejiang University School of Medicine, Yiwu, 322000, Zhejiang, China.
| |
Collapse
|
21
|
Coordination of thin-film nanofibrous composite dialysis membrane and reduced graphene oxide aerogel adsorbents for elimination of indoxyl sulfate. Chin J Chem Eng 2022. [DOI: 10.1016/j.cjche.2022.01.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
22
|
Li W, Chao S, Li Y, Bai F, Teng Y, Li X, Li L, Wang C. Dual-layered composite nanofiber membrane with Cu-BTC-modified electrospun nanofibers and biopolymeric nanofibers for the removal of uremic toxins and its application in hemodialysis. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2021.119964] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
23
|
Porous cellulose acetate mixed-matrix membrane adsorbents for efficient clearance of p-cresol and creatinine from synthetic serum. J Taiwan Inst Chem Eng 2022. [DOI: 10.1016/j.jtice.2021.104199] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
24
|
Geremia I, A.W. Jong J, van Nostrum CF, Hennink WE, G.F. Gerritsen K, Stamatialis D. New mixed matrix membrane for the removal of urea from dialysate solution. Sep Purif Technol 2021. [DOI: 10.1016/j.seppur.2021.119408] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
25
|
Rosner MH, Reis T, Husain-Syed F, Vanholder R, Hutchison C, Stenvinkel P, Blankestijn PJ, Cozzolino M, Juillard L, Kashani K, Kaushik M, Kawanishi H, Massy Z, Sirich TL, Zuo L, Ronco C. Classification of Uremic Toxins and Their Role in Kidney Failure. Clin J Am Soc Nephrol 2021; 16:1918-1928. [PMID: 34233920 PMCID: PMC8729494 DOI: 10.2215/cjn.02660221] [Citation(s) in RCA: 75] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Advances in our understanding of uremic retention solutes, and improvements in hemodialysis membranes and other techniques designed to remove uremic retention solutes, offer opportunities to readdress the definition and classification of uremic toxins. A consensus conference was held to develop recommendations for an updated definition and classification scheme on the basis of a holistic approach that incorporates physicochemical characteristics and dialytic removal patterns of uremic retention solutes and their linkage to clinical symptoms and outcomes. The major focus is on the removal of uremic retention solutes by hemodialysis. The identification of representative biomarkers for different classes of uremic retention solutes and their correlation to clinical symptoms and outcomes may facilitate personalized and targeted dialysis prescriptions to improve quality of life, morbidity, and mortality. Recommendations for areas of future research were also formulated, aimed at improving understanding of uremic solutes and improving outcomes in patients with CKD.
Collapse
Affiliation(s)
- Mitchell H. Rosner
- Division of Nephrology, University of Virginia Health System, Charlottesville, Virginia
| | - Thiago Reis
- Department of Nephrology, University of Brazil, Brasília, Brazil
- National Academy of Medicine, Rio de Janeiro, Brazil
| | - Faeq Husain-Syed
- Department of Internal Medicine II, Justus-Liebig-University Giessen, Giessen, Germany
| | - Raymond Vanholder
- Department of Internal Medicine and Pediatrics, University Hospital, Ghent, Belgium
| | - Colin Hutchison
- Faculty of Medicine, University of Queensland, Herston, Australia
- Department of Medicine, Hawke's Bay District Health Board, Hastings, New Zealand
| | - Peter Stenvinkel
- Renal Medicine, Karolinska University Hospital, Stockholm, Sweden
| | - Peter J. Blankestijn
- Department of Nephrology and Hypertension, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Mario Cozzolino
- Renal Division, Università degli Studi di Milano, Milan, Italy
| | - Laurent Juillard
- University of Lyon, Villeurbanne, France
- Hôpital E. Herriot, Lyon, France
| | - Kianoush Kashani
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota
| | - Manish Kaushik
- Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore
| | - Hideki Kawanishi
- Department of Artificial Organs, Tsuchiya General Hospital, Hiroshima, Japan
| | - Ziad Massy
- INSERM U1018, Villejuif, France
- Service de Néphrologie et Dialyse, Hôpital Universitaire Ambroise Paré, Boulogne-Billancourt, France
| | - Tammy Lisa Sirich
- Nephrology Section, Veterans Affairs Palo Alto Health Care System, Palo Alto, California
- Division of Nephrology, Stanford University School of Medicine, Stanford, California
| | - Li Zuo
- Department of Nephrology, Peking University People's Hospital, Beijing, China
| | - Claudio Ronco
- Department of Medicine, University of Padova, Padova, Italy
- Department of Nephrology, Dialysis and Transplantation, International Renal Research Institute of Vicenza, Vicenza, Italy
| |
Collapse
|
26
|
Abstract
PURPOSE OF REVIEW Improvement in hemodialysis treatment and membrane technology are focused on two aims: the first one is to achieve a better control of circulating uremic solutes by enhancing removal capacity and by broadening molecular weight spectrum of solutes cleared; the second one is to prevent inflammation by improving hemocompatibility of the global dialysis system. RECENT FINDINGS Despite impressive progresses in polymers chemistry few hazards are still remaining associated with leaching or sensitization to polymer additives. Research has focused on developing more stable polymers by means of additives or processes aiming to minimize such risks. Membrane engineering manufacturing with support of nanocontrolled spinning technology has opened up membrane to middle and large molecular weight substances, while preserving albumin losses. Combination of diffusive and enhanced convective fluxes in the same hemodialyzer module, namely hemodiafiltration, provides today the highest solute removal capacity over a broad spectrum of solutes. SUMMARY Dialysis membrane is a crucial component of the hemodialysis system to optimize solute removal efficacy and to minimize blood membrane biological reactions. Hemodialyzer is much more than a membrane. Dialysis membrane and hemodialyzer choice are parts of a treatment chain that should be operated in optimized conditions and adjusted to patient needs and tolerance, to improve patient outcomes.
Collapse
Affiliation(s)
- Bernard Canaud
- Global Medical Office, FMC Deutschland, Bad Homburg, Germany
- University of Montpellier, UFR of Medicine, Montpellier, France
| |
Collapse
|
27
|
Wang SC, Liu SH, Fu CC, Hsiao YS, Juang RS. Design and fabrication of electrospun mixed-matrix multi-layered membranes containing tri-n-octylphosphine oxide for efficient adsorption of p-cresol. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.127192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
28
|
Shi Y, Tian H, Wang Y, Shen Y, Zhu Q, Ding F. Improved Dialysis Removal of Protein-Bound Uraemic Toxins with a Combined Displacement and Adsorption Technique. Blood Purif 2021; 51:548-558. [PMID: 34515053 DOI: 10.1159/000518065] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 06/04/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Protein-bound uraemic toxins (PBUTs) are poorly removed by conventional dialytic techniques, given their high plasma protein binding, and thus low, free (dialysable) plasma concentration. Here, we evaluated and compared PBUTs removal among conventional haemodialysis (HD), adsorption-based HD, displacement-based HD, and their 2 combinations both in vitro and in vivo. METHODS The removal of PBUTs, including 3-carboxy-4-methyl-5-propyl-2-furan-propanoic acid (CMPF), p-cresyl sulphate (PCS), indoxyl sulphate (IS), indole-3-acetic acid (3-IAA), and hippuric acid, was first evaluated in an in vitro single-pass HD model. Adsorption consisted of adding 40 g/L bovine serum albumin (Alb) to the dialysate and displacement involved infusing fatty acid (FA) mixtures predialyser. Then, uraemic rats were treated with either conventional HD, Alb-based HD, lipid emulsion infusion-based HD or their combination to calculate the reduction ratio (RR), and the total solute removal (TSR) of solutes after 4 h of therapy. RESULTS In vitro dialysis revealed that FAs infusion prefilter increased the removal of PCS, IS, and 3-IAA 3.23-fold, 3.01-fold, and 2.24-fold, respectively, compared with baseline and increased the fractional removal of CMPF from undetectable at baseline to 14.33 ± 0.24%, with a dialysis efficacy markedly superior to Alb dialysis. In vivo dialysis showed that ω-6 soybean oil-based lipid emulsion administration resulted in higher RRs and more TSRs for PCS, IS, and 3-IAA after 4-h HD than the control, and the corresponding TSR values for PCS and IS were also significantly increased compared to that of Alb dialysis. Finally, the highest dialysis efficacy for highly bound solute removal was always observed with their combination both in vitro and in vivo. CONCLUSIONS The concept of combined displacement- and adsorption-based dialysis may open up new avenues and possibilities in the field of dialysis to further enhance PBUTs removal in end-stage renal disease.
Collapse
Affiliation(s)
- Yuanyuan Shi
- Department of Nephrology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China, .,Department of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China,
| | - Huajun Tian
- Department of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Yifeng Wang
- Department of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Yue Shen
- Department of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Qiuyu Zhu
- Department of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Feng Ding
- Department of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| |
Collapse
|
29
|
Heparin immobilized graphene oxide in polyetherimide membranes for hemodialysis with enhanced hemocompatibility and removal of uremic toxins. J Memb Sci 2021. [DOI: 10.1016/j.memsci.2021.119068] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
30
|
ter Beek O, van Gelder M, Lokhorst C, Hazenbrink D, Lentferink B, Gerritsen K, Stamatialis D. In vitro study of dual layer mixed matrix hollow fiber membranes for outside-in filtration of human blood plasma. Acta Biomater 2021; 123:244-253. [PMID: 33450414 DOI: 10.1016/j.actbio.2020.12.063] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 12/21/2020] [Accepted: 12/22/2020] [Indexed: 12/17/2022]
Abstract
Hemodialysis mainly removes small water-soluble uremic toxins but cannot effectively remove middle molecules and protein-bound uremic toxins. Besides, the therapy is intermittent leading to fluctuating blood values and fluid status which adversely impacts patients' health. Prolonged hemodialysis (with adequate anticoagulation) could improve the removal of toxins and the development of portable and wearable artificial kidneys could offer more flexibility in the dialysis scheme. This would enhance patients' overall health, autonomy, mobility and flexibility, allowing patients to participate in social and economic life. However, the time that patients' blood is exposed to the dialyzer material is longer during prolonged hemodialysis, and blood clots could obstruct the fiber lumen, resulting in a decrease of the effective membrane surface area available for toxin removal. The outside-in filtration (OIF) mode, wherein blood flows through the inter-fiber space instead of through the fiber lumina, has been applied widely in blood oxygenators to prevent fiber clotting, but not in hemodialysis. In this study, we present for the first time the development of a mixed matrix membrane (MMM) for OIF of human blood plasma. This MMM combines diffusion and adsorption and consists of a polymeric membrane matrix with activated carbon (AC) particles on the inside layer, and a polymeric particle-free layer on the outer fiber layer. Our results show that in vitro MMM fibers for OIF demonstrate superior removal of the protein-bound uremic toxins, indoxyl sulfate and hippuric acid, compared to both earlier MMM fibers designed for inside-out filtration mode and commercial high-flux fibers. STATEMENT OF SIGNIFICANCE: Current hemodialysis therapy cannot effectively remove protein-bound toxins. Prolonged hemodialysis could improve toxin removal. However, during prolonged hemodialysis, blood clots could obstruct the fiber lumen, resulting in decreased effective membrane surface area available for toxin removal. We have prepared, for the first time, dual layer mixed matrix hollow fiber membranes (MMM) for outside-in filtration (OIF). The OIF mode wherein blood would flow through the inter-fiber space instead of through the fiber lumina could prevent fiber clotting. Moreover, the MMMs combine diffusion and adsorption to improve (protein-bound) toxin removal. We believe that the new design of our MMM fibers is an important contribution concerning the development of artificial kidney systems and the improvement of the health and well-being of patients with renal failure.
Collapse
|
31
|
Challenges of reducing protein-bound uremic toxin levels in chronic kidney disease and end stage renal disease. Transl Res 2021; 229:115-134. [PMID: 32891787 DOI: 10.1016/j.trsl.2020.09.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 08/24/2020] [Accepted: 09/02/2020] [Indexed: 12/11/2022]
Abstract
The prevalence of chronic kidney disease (CKD) in the worldwide population is currently estimated between 11% and 13%. Adequate renal clearance is compromised in these patients and the accumulation of a large number of uremic retention solutes results in an irreversible worsening of renal function which can lead to end stage renal disease (ESRD). Approximately three million ESRD patients currently receive renal replacement therapies (RRTs), such as hemodialysis, which only partially restore kidney function, as they are only efficient in removing mainly small, unbound solutes from the circulation while leaving larger and protein-bound uremic toxins (PBUTs) untouched. The accumulation of PBUTs in patients highly increases the risk of cardiovascular events and is associated with higher mortality and morbidity in CKD and ESRD. In this review, we address several strategies currently being explored toward reducing PBUT concentrations, including clinical and medical approaches, therapeutic techniques, and recent developments in RRT technology. These include preservation of renal function, limitation of colon derived PBUTs, oral sorbents, adsorbent RRT technology, and use of albumin displacers. Despite the promising results of the different approaches to promote enhanced removal of a small percentage of the more than 30 identified PBUTs, on their own, none of them provide a treatment with the required efficiency, safety and cost-effectiveness to prevent CKD-related complications and decrease mortality and morbidity in ESRD.
Collapse
|
32
|
Yamamoto S, Sasahara K, Domon M, Yamaguchi K, Ito T, Goto S, Goto Y, Narita I. pH-Dependent Protein Binding Properties of Uremic Toxins In Vitro. Toxins (Basel) 2021; 13:toxins13020116. [PMID: 33557434 PMCID: PMC7914709 DOI: 10.3390/toxins13020116] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 01/30/2021] [Accepted: 02/01/2021] [Indexed: 12/22/2022] Open
Abstract
Protein-bound uremic toxins (PBUTs) are difficult to remove using conventional dialysis treatment owing to their high protein-binding affinity. As pH changes the conformation of proteins, it may be associated with the binding of uremic toxins. Albumin conformation at pH 2 to 13 was analyzed using circular dichroism. The protein binding behavior between indoxyl sulfate (IS) and albumin was examined using isothermal titration calorimetry. Albumin with IS, and serum with IS, p-cresyl sulfate, indole acetic acid or phenyl sulfate, as well as serum from hemodialysis patients, were adjusted pH of 3 to 11, and the concentration of the free PBUTs was measured using mass spectrometry. Albumin was unfolded at pH < 4 or >12, and weakened interaction with IS occurred at pH < 5 or >10. The concentration of free IS in the albumin solution was increased at pH 4.0 and pH 11.0. Addition of human serum to each toxin resulted in increased free forms at acidic and alkaline pH. The pH values of serums from patients undergoing hemodialysis adjusted to 3.4 and 11.3 resulted in increased concentrations of the free forms of PBUTs. In conclusion, acidic and alkaline pH conditions changed the albumin conformation and weakened the protein binding property of PBUTs in vitro.
Collapse
Affiliation(s)
- Suguru Yamamoto
- Division of Clinical Nephrology and Rheumatology, Niigata University Graduate School of Medical and Dental Sciences, Niigata 951-8510, Japan; (M.D.); (T.I.); (S.G.); (I.N.)
- Correspondence: ; Tel.: +81-25-227-2200
| | - Kenichi Sasahara
- Institute for Protein Research, Osaka University, Yamadaoka 3-2, Suita, Osaka 565-0871, Japan; (K.S.); (K.Y.); (Y.G.)
| | - Mio Domon
- Division of Clinical Nephrology and Rheumatology, Niigata University Graduate School of Medical and Dental Sciences, Niigata 951-8510, Japan; (M.D.); (T.I.); (S.G.); (I.N.)
| | - Keiichi Yamaguchi
- Institute for Protein Research, Osaka University, Yamadaoka 3-2, Suita, Osaka 565-0871, Japan; (K.S.); (K.Y.); (Y.G.)
| | - Toru Ito
- Division of Clinical Nephrology and Rheumatology, Niigata University Graduate School of Medical and Dental Sciences, Niigata 951-8510, Japan; (M.D.); (T.I.); (S.G.); (I.N.)
| | - Shin Goto
- Division of Clinical Nephrology and Rheumatology, Niigata University Graduate School of Medical and Dental Sciences, Niigata 951-8510, Japan; (M.D.); (T.I.); (S.G.); (I.N.)
| | - Yuji Goto
- Institute for Protein Research, Osaka University, Yamadaoka 3-2, Suita, Osaka 565-0871, Japan; (K.S.); (K.Y.); (Y.G.)
| | - Ichiei Narita
- Division of Clinical Nephrology and Rheumatology, Niigata University Graduate School of Medical and Dental Sciences, Niigata 951-8510, Japan; (M.D.); (T.I.); (S.G.); (I.N.)
| |
Collapse
|
33
|
Vanholder R, Argilés A, Jankowski J. A history of uraemic toxicity and of the European Uraemic Toxin Work Group (EUTox). Clin Kidney J 2021; 14:1514-1523. [PMID: 34413975 PMCID: PMC8371716 DOI: 10.1093/ckj/sfab011] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Indexed: 12/13/2022] Open
Abstract
The uraemic syndrome is a complex clinical picture developing in the advanced stages of chronic kidney disease, resulting in a myriad of complications and a high early mortality. This picture is to a significant extent defined by retention of metabolites and peptides that with a preserved kidney function are excreted or degraded by the kidneys. In as far as those solutes have a negative biological/biochemical impact, they are called uraemic toxins. Here, we describe the historical evolution of the scientific knowledge about uraemic toxins and the role played in this process by the European Uraemic Toxin Work Group (EUTox) during the last two decades. The earliest knowledge about a uraemic toxin goes back to the early 17th century when the existence of what would later be named as urea was recognized. It took about two further centuries to better define the role of urea and its link to kidney failure, and one more century to identify the relevance of post-translational modifications caused by urea such as carbamoylation. The knowledge progressively extended, especially from 1980 on, by the identification of more and more toxins and their adverse biological/biochemical impact. Progress of knowledge was paralleled and impacted by evolution of dialysis strategies. The last two decades, when insights grew exponentially, coincide with the foundation and activity of EUTox. In the final section, we summarize the role and accomplishments of EUTox and the part it is likely to play in future action, which should be organized around focus points like biomarker and potential target identification, intestinal generation, toxicity mechanisms and their correction, kidney and extracorporeal removal, patient-oriented outcomes and toxin characteristics in acute kidney injury and transplantation.
Collapse
Affiliation(s)
- Raymond Vanholder
- Department of Internal Medicine and Pediatrics, Nephrology Section, Ghent University Hospital, Ghent, Belgium
| | - Angel Argilés
- RD-Néphrologie, Montpellier, France.,Néphrologie Dialyse St Guilhem, Sète, France
| | - Joachim Jankowski
- Institute for Molecular Cardiovascular Research, University Hospital, RWTH Aachen, Aachen, Germany.,School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | | |
Collapse
|
34
|
Daneshamouz S, Eduok U, Abdelrasoul A, Shoker A. Protein-bound uremic toxins (PBUTs) in chronic kidney disease (CKD) patients: Production pathway, challenges and recent advances in renal PBUTs clearance. NANOIMPACT 2021; 21:100299. [PMID: 35559786 DOI: 10.1016/j.impact.2021.100299] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 01/13/2021] [Accepted: 01/20/2021] [Indexed: 06/15/2023]
Abstract
Uremic toxins, a group of uremic retention solutes with high concentration which their accumulation on the body makes several biological problems, have recently gained a large interest. The importance of this issue more targets patients with compromised kidney function since the presence of these toxins in their bodies contributes to serious illness and death. It is reported that around 14% of people are subjected of CKD's problems. Among different classifications of uremic toxins, protein bound uremic toxins are poorly removed from the body as they tightly bind to proteins like serum albumin. A deeper and closer understanding of methods for removing protein bound uremic toxins and their efficiency is of paramount importance. This article discussed the most critical protein bound uremic toxins from different points of view including their chemistry, binding sites, interactions, and their biological impacts. Concerning the toxicity and high concentration, p-cresyl sulfate (PCS), Indoxyl sulfate (IS), 3-Carboxy-4-methyl-5-propyl-2-furanpropionic acid (CMPF), and Indole- 3-acetic acid (IAA) was chosen to study in this article. Results offered that the functional groups of mentioned PBUTs and the way that they interact with the adsorbent play an important role in finding substances for removal of them. Furthermore, the development of nanoparticle (NPs) for promising biomedical purposes has been explored. However, there is still a need for further investigation to find biocompatible substances focusing on the removal of PBUTs. PBUTs are a unique class of uremic toxins whose renal clearance mechanisms and role in uremic pathophysiology are still unclear. This review outlines the biochemical aspects of PBUT/protein binding in a view to explaining their renal formation to elimination mechanisms; some examples are drawn from routes involving albumin-binding with indoxyl sulphate, p-cresyl sulfate, p-cresyl glucuronide and hippuric acid. We have also highlighted the kinetic behaviors during dialytic removal of PBUTs to address future concerns regarding dialytic therapy.
Collapse
Affiliation(s)
- Sana Daneshamouz
- Department of Chemical and Biological Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, Saskatchewan S7N 5A9, Canada
| | - Ubong Eduok
- Department of Chemical and Biological Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, Saskatchewan S7N 5A9, Canada
| | - Amira Abdelrasoul
- Department of Chemical and Biological Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, Saskatchewan S7N 5A9, Canada; Department of Biomedical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, Saskatchewan S7N 5A9, Canada.
| | - Ahmed Shoker
- Nephrology Division, College of Medicine, University of Saskatchewan, 107 Wiggins Rd, Saskatoon, SK S7N 5E5, Canada; Saskatchewan Transplant Program, St. Paul's Hospital, 1702 20th Street West Saskatoon Saskatchewan S7M 0Z9, Canada
| |
Collapse
|
35
|
Toth-Manikowski SM, Sirich TL, Meyer TW, Hostetter TH, Hwang S, Plummer NS, Hai X, Coresh J, Powe NR, Shafi T. Contribution of 'clinically negligible' residual kidney function to clearance of uremic solutes. Nephrol Dial Transplant 2020; 35:846-853. [PMID: 30879076 DOI: 10.1093/ndt/gfz042] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Accepted: 02/03/2019] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Residual kidney function (RKF) is thought to exert beneficial effects through clearance of uremic toxins. However, the level of native kidney function where clearance becomes negligible is not known. METHODS We aimed to assess whether levels of nonurea solutes differed among patients with 'clinically negligible' RKF compared with those with no RKF. The hemodialysis study excluded patients with urinary urea clearance >1.5 mL/min, below which RKF was considered to be 'clinically negligible'. We measured eight nonurea solutes from 1280 patients participating in this study and calculated the relative difference in solute levels among patients with and without RKF based on measured urinary urea clearance. RESULTS The mean age of the participants was 57 years and 57% were female. At baseline, 34% of the included participants had clinically negligible RKF (mean 0.7 ± 0.4 mL/min) and 66% had no RKF. Seven of the eight nonurea solute levels measured were significantly lower in patients with RKF than in those without RKF, ranging from -24% [95% confidence interval (CI) -31 to -16] for hippurate, -7% (-14 to -1) for trimethylamine-N-oxide and -4% (-6 to -1) for asymmetric dimethylarginine. The effect of RKF on plasma levels was comparable or more pronounced than that achieved with a 31% higher dialysis dose (spKt/Vurea 1.7 versus 1.3). Preserved RKF at 1-year follow-up was associated with a lower risk of cardiac death and first cardiovascular event. CONCLUSIONS Even at very low levels, RKF is not 'negligible', as it continues to provide nonurea solute clearance. Management of patients with RKF should consider these differences.
Collapse
Affiliation(s)
| | - Tammy L Sirich
- Department of Medicine, Division of Nephrology, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Timothy W Meyer
- Department of Medicine, Division of Nephrology, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Thomas H Hostetter
- Department of Medicine, Palo Alto Veterans Affairs Health Care System, Stanford University, Palo Alto, CA, USA
| | - Seungyoung Hwang
- Department of Medicine, Division of Nephrology, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Natalie S Plummer
- Department of Medicine, Division of Nephrology, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Xin Hai
- Department of Medicine, Palo Alto Veterans Affairs Health Care System, Stanford University, Palo Alto, CA, USA
| | - Josef Coresh
- Department of Medicine, Case Western Reserve University, Cleveland, OH, USA.,Welch Center for Prevention, Epidemiology and Clinical Research, Johns Hopkins University, Baltimore, MD, USA
| | - Neil R Powe
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| | - Tariq Shafi
- Department of Medicine, Division of Nephrology, Johns Hopkins School of Medicine, Baltimore, MD, USA.,Department of Medicine, Case Western Reserve University, Cleveland, OH, USA.,Welch Center for Prevention, Epidemiology and Clinical Research, Johns Hopkins University, Baltimore, MD, USA.,Department of Medicine, Priscilla Chan and Mark Zuckerberg San Francisco General Hospital, University of California, San Francisco, San Francisco, CA, USA
| |
Collapse
|
36
|
Shen Y, Shen Y, Bi X, Li J, Chen Y, Zhu Q, Wang Y, Ding F. Linoleic acid-modified liposomes for the removal of protein-bound toxins: An in vitro study. Int J Artif Organs 2020; 44:393-403. [PMID: 33135543 DOI: 10.1177/0391398820968837] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
INTRODUCTION Protein-bound uremic toxins (PBUTs) and liver failure-related cholestatic solutes are associated with adverse outcomes in patients with chronic kidney disease (CKD) and liver failure, respectively, and are not easily removed by traditional dialysis therapies. We constructed linoleic acid-modified liposomes (LA-liposomes) as indirect adsorbent in the dialysate, and evaluated their effects on the clearance of the representative PBUTs and cholestatic solutes. METHODS The LA-liposomes were prepared by the thin-film hydration method. The binding rates of liposomes and protein-bound solutes were detected by the ultrafiltration column. The in vitro dialysis experiments were performed using both non-current and current devices to assay the clearing efficiency of the dialysate supported by LA-liposomes. RESULTS The LA-liposomes exhibited good binding properties to the PBUTs, bilirubin and bile acids. The LA-liposome dialysate showed higher solute reduction rates of the representative PBUTs and cholestatic solutes than the traditional dialysate or dialysate supported by the unmodified plain liposomes. Also, albumin binding of the PBUTs was significantly inhibited by the addition of linoleic acid (LA), and the removal efficiency of PBUTs was greatly enhanced by the combination of indirect adsorbent LA-liposomes and LA as the competitive displacer. CONCLUSION LA-liposomes were efficient in the clearance of the representative PBUTs and liver failure-related solutes. Moreover, the combination of indirect adsorbent LA-liposomes and competitive displacer suggested a potential application for the extremely highly-bound solutes.
Collapse
Affiliation(s)
- Yue Shen
- Division of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai JiaoTong University, Shanghai, China
| | - Yuqi Shen
- Division of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai JiaoTong University, Shanghai, China
| | - Xiao Bi
- Division of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai JiaoTong University, Shanghai, China
| | - Jiaolun Li
- Division of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai JiaoTong University, Shanghai, China
| | - Yingjie Chen
- Division of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai JiaoTong University, Shanghai, China
| | - Qiuyu Zhu
- Division of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai JiaoTong University, Shanghai, China
| | - Yifeng Wang
- Division of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai JiaoTong University, Shanghai, China
| | - Feng Ding
- Division of Nephrology, Shanghai Ninth People's Hospital, School of Medicine, Shanghai JiaoTong University, Shanghai, China
| |
Collapse
|
37
|
Prediction of toxin removal efficiency of novel hemodialysis multilayered mixed-matrix membranes. Sep Purif Technol 2020. [DOI: 10.1016/j.seppur.2020.117272] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
38
|
Li J, Han L, Xie J, Liu S, Jia L. Multi-sites polycyclodextrin adsorbents for removal of protein-bound uremic toxins combining with hemodialysis. Carbohydr Polym 2020; 247:116665. [DOI: 10.1016/j.carbpol.2020.116665] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 06/16/2020] [Accepted: 06/16/2020] [Indexed: 12/23/2022]
|
39
|
Liu Y, Zhong Z, Wu Q, Liu F, Shi ZQ, Yao ZP, Di X. Enhancing enrichment ability of ZIF-8 mixed matrix membrane microextraction by reverse micelle strategy for analysis of multiple ionizable bioactive components in biological samples. Talanta 2020; 217:121030. [PMID: 32498909 DOI: 10.1016/j.talanta.2020.121030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 04/08/2020] [Accepted: 04/10/2020] [Indexed: 10/24/2022]
Abstract
Recent research aimed at the design of mixed-matrix membrane (MMM) to be used for microextraction emphasized on membrane extraction phase with high surface area and porosity. This study explored the influence that surfactants have on MMM extraction efficiency for the first time. The zeolitic imidazolate framework 8-based MMM (ZIF-8-MMM) was synthesized by in situ self-assembly of ZIF-8 on the inner wall of a hollow fiber membrane with the aim of fabricating a microextraction device. By prompting the encapsulation of ionizable analytes in the polar core of reverse micelles, the presence of surfactants in extraction solvent assisted the dissolution of analytes in the fiber membrane lumen and enhanced their adsorption onto ZIF-8. Notably, hereby a microextraction method based on the novel ZIF-8-MMM-reverse micelle (ZIF-8-MMM-RM) system was developed and employed for the extraction and quantitation of two alkaloids (berberine and jatrorrhizine) and two flavonoids (wogonin and wogonoside) in biological samples. The main factors affecting microextraction performance, identity of the extraction solvent, surfactant concentration, sample solution pH and extraction time, were investigated in detail. The method showed good linearity (r2 > 0.99) and repeatability (RSD < 10%), low limits of detection (0.10-0.31 ng mL-1) and high relative recoveries (90.03-98.84%). The enrichment factor values ranged between 48.47 and 54.96. Reverse micelle formation prompted by surfactant addition was demonstrated to effectively assist the extraction of multiple ionizable analytes from biological samples, resulting in a marked improvement of ZIF-8-MMM extraction performance.
Collapse
Affiliation(s)
- Yangdan Liu
- School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road, Shenyang, China
| | - Zhujun Zhong
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, China Pharmaceutical University, NO.24 Tongjia Lane, Nanjing, China
| | - Qinchang Wu
- College of Pharmacy, Jinan University, Guangzhou, China
| | - Fengjie Liu
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, China Pharmaceutical University, NO.24 Tongjia Lane, Nanjing, China
| | - Zi-Qi Shi
- Key Laboratory of New Drug Delivery Systems of Chinese Materia Medica, Jiangsu Provincial Academy of Chinese Medicine, Jiangsu, Nanjing, China
| | - Zhong-Ping Yao
- State Key Laboratory of Chemical Biology and Drug Discovery, Food Safety and Technology Research Centre and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China; State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation) and Shenzhen Key Laboratory of Food Biological Safety Control, Shenzhen Research Institute of Hong Kong Polytechnic University, Shenzhen, 518057, China.
| | - Xin Di
- School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road, Shenyang, China.
| |
Collapse
|
40
|
Jiang P, He Y, Zhao Y, Chen L. Hierarchical Surface Architecture of Hemodialysis Membranes for Eliminating Homocysteine Based on the Multifunctional Role of Pyridoxal 5'-phosphate. ACS APPLIED MATERIALS & INTERFACES 2020; 12:36837-36850. [PMID: 32705861 DOI: 10.1021/acsami.0c07090] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Patients with end-stage renal disease are prone to developing a complication of hyperhomocysteinemia, manifesting as an elevation of the homocysteine (Hcy) concentration in human plasma. However, Hcy as a protein-bound toxin is barely removed by conventional hemodialysis membranes. Here, we report a novel hemodialysis membrane by preparing a bioactive coating of pyridoxal 5'-phosphate (PLP) and adding biocompatible hyperbranched polyglycerol (HPG) brushes to achieve Hcy removal. The dip-applied PLP coating, a coenzyme with a role in Hcy metabolism, dramatically promoted a decrease in the Hcy concentration in human plasma. Moreover, the aldehyde group of PLP had an intrinsic chemical reactivity toward the terminal amino group to immobilize the HPG brushes on the hemodialysis membrane surface. The hierarchical PLP-HPG layer-functionalized membranes had a high efficacy for eliminating Hcy, with a concentration from the initial stage of 150 μmol/L reduced to a nearly normal level of 20 μmol/L in simulated dialysis. By analyzing the impact of HPG brushes with various chain lengths, we found that HPG brushes with a medium length enabled the PLP coating with the bioactive function of Hcy conversion to additionally protect Hcy-attacked target cells by providing excellent hydrophilicity and a dense enough chain volume overlap of the hyperbranched architecture. Simultaneously, the densely packed HPG brushes generated a maximal steric and hydration barrier that significantly improved biofouling resistance against blood proteins. The optimally functionalized membranes showed a clearance of 83.1% urea and 49.6% lysozyme and a rejection of 96.0% bovine serum albumin. The diversely functionalized PLP-HPG layers demonstrate a potential route for a more integrated hemodialysis membrane that can cope with the urgent issue of hyperhomocysteinemia in clinical hemodialysis therapy.
Collapse
Affiliation(s)
- Peng Jiang
- State Key Laboratory of Separation Membranes and Membrane Processes, School of Materials Science and Engineering, Tiangong University, Tianjin 300387, China
| | - Yang He
- State Key Laboratory of Separation Membranes and Membrane Processes, School of Materials Science and Engineering, Tiangong University, Tianjin 300387, China
| | - Yiping Zhao
- State Key Laboratory of Separation Membranes and Membrane Processes, School of Materials Science and Engineering, Tiangong University, Tianjin 300387, China
| | - Li Chen
- State Key Laboratory of Separation Membranes and Membrane Processes, School of Materials Science and Engineering, Tiangong University, Tianjin 300387, China
| |
Collapse
|
41
|
Fu CC, Hsiao YS, Ke JW, Syu WL, Liu TY, Liu SH, Juang RS. Adsorptive removal of p-cresol and creatinine from simulated serum using porous polyethersulfone mixed-matrix membranes. Sep Purif Technol 2020. [DOI: 10.1016/j.seppur.2020.116884] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
42
|
|
43
|
Zainol Abidin MN, Goh PS, Said N, Ismail AF, Othman MHD, Hasbullah H, Abdullah MS, Ng BC, Sheikh Abdul Kadir SH, Kamal F, Mansur S. Co-Adsorptive Removal of Creatinine and Urea by a Three-Component Dual-Layer Hollow Fiber Membrane. ACS APPLIED MATERIALS & INTERFACES 2020; 12:33276-33287. [PMID: 32589391 DOI: 10.1021/acsami.0c08947] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The development of wearable artificial kidney demands an efficient dialysate recovery, which relies upon the adsorption process. This study proposes a solution to solve the problem of competitive adsorption between the uremic toxins by employing two adsorptive components in a membrane separation process. Dual-layer hollow fiber (DLHF) membranes, which are composed of a polysulfone (PSf)/activated carbon (AC) inner layer and a PSf/poly(methyl methacrylate) (PMMA) outer layer, were prepared for co-adsorptive removal of creatinine and urea from aqueous solution. The DLHF membranes were characterized in terms of morphological, physicochemical, water transport, and creatinine adsorption properties. The membrane was then subjected to an ultrafiltration adsorption study for performance evaluation. The incorporation of AC in membrane, as confirmed by microscopic and surface analyses, has improved the pure water flux up to 25.2 L/(m2 h). A membrane with optimum AC loading (9 wt %) demonstrated the highest maximum creatinine adsorption capacity (86.2 mg/g) based on the Langmuir adsorption isotherm model. In the ultrafiltration adsorption experiment, the membrane removed creatinine and urea with a combined average percent removal of 29.3%. Moreover, the membrane exhibited creatinine and urea uptake recoveries of 98.8 and 81.2%, respectively. The combined action of PMMA and AC in the PSf DLHF membrane has made the adsorption of multiple uremic toxins possible during dialysate recovery.
Collapse
Affiliation(s)
- Muhammad Nidzhom Zainol Abidin
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Johor Darul Ta'zim, 81310 Skudai, Malaysia
| | - Pei Sean Goh
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Johor Darul Ta'zim, 81310 Skudai, Malaysia
| | - Noresah Said
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Johor Darul Ta'zim, 81310 Skudai, Malaysia
| | - Ahmad Fauzi Ismail
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Johor Darul Ta'zim, 81310 Skudai, Malaysia
| | - Mohd Hafiz Dzarfan Othman
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Johor Darul Ta'zim, 81310 Skudai, Malaysia
| | - Hasrinah Hasbullah
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Johor Darul Ta'zim, 81310 Skudai, Malaysia
| | - Mohd Sohaimi Abdullah
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Johor Darul Ta'zim, 81310 Skudai, Malaysia
| | - Be Cheer Ng
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Johor Darul Ta'zim, 81310 Skudai, Malaysia
| | - Siti Hamimah Sheikh Abdul Kadir
- Institute of Medical Molecular Biotechnology (IMMB), Faculty of Medicine, Universiti Teknologi MARA Sungai Buloh Campus, Jalan Hospital, 47000 Sungai Buloh, Selangor, Malaysia
| | - Fatmawati Kamal
- Institute of Medical Molecular Biotechnology (IMMB), Faculty of Medicine, Universiti Teknologi MARA Sungai Buloh Campus, Jalan Hospital, 47000 Sungai Buloh, Selangor, Malaysia
| | - Sumarni Mansur
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Johor Darul Ta'zim, 81310 Skudai, Malaysia
| |
Collapse
|
44
|
Geremia I, Pavlenko D, Maksymow K, Rüth M, Lemke HD, Stamatialis D. Ex vivo evaluation of the blood compatibility of mixed matrix haemodialysis membranes. Acta Biomater 2020; 111:118-128. [PMID: 32447066 DOI: 10.1016/j.actbio.2020.05.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 04/16/2020] [Accepted: 05/13/2020] [Indexed: 02/07/2023]
Abstract
The patients with end stage kidney disease need haemodialysis therapies, using an artificial kidney. Nevertheless, the current therapies cannot remove a broad range of uremic toxins compared to the natural kidney. Adsorption therapies, using sorbent-based columns, can improve the clearance of uremic toxins, but the sorbent particles often require polymeric coatings to improve their haemocompatibility leading to mass transfer limitations and to lowering of their performance. Earlier, we have developed a dual layer Mixed Matrix fiber Membrane (MMM) based on polyethersulfone/polyvinylpyrrolidone (PES/PVP) polymer blends. There, the sorbent activated carbon particles are embedded in the outer membrane layer for achieving higher removal whereas the inner blood contacting selective membrane layer should achieve optimal blood compatibility. In this work, we evaluate in detail the haemocompatibility of the MMM following the norm ISO 10993-4. We study two generations of MMM having different dimensions and transport characteristics; one with low flux and no albumin leakage and another with high flux but some albumin leakage. The results are compared to those of home-made PES/PVP single layer hollow fiber and to various control fibers already applied in the clinic. Our results show that the low flux MMM successfully avoids contact of blood with the activated carbon and has good haemocompatibility, comparable to membranes currently used in the clinic. STATEMENT OF SIGNIFICANCE: Haemodialysis is a life-sustaining extracorporeal treatment for renal disease, however a broad range of uremic toxins cannot still be removed. In our previous works we showed that a double layer Mixed Matrix Membrane (MMM) composed of polyethersulfone/polyvinylpyrrolidone and activated carbon can achieve higher removal of uremic toxics compared to commercial haemodialysers. In this work we evaluate the haemocompatibility profile of the MMM in order to facilitate its clinical implementation. The lumen particle-free layer of the MMM successfully avoids the contact of blood with the poorly blood-compatible activated carbon. Moreover, thanks to the high amount of polyvinylpyrrolidone and to the smoothness of the lumen layer, the MMM has very good haemocompatibility, comparable to membranes currently used in the clinic.
Collapse
Affiliation(s)
- I Geremia
- (Bio)artificial organs, Department of Biomaterials Science and Technology, TechMed Centre, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, the Netherlands
| | - D Pavlenko
- (Bio)artificial organs, Department of Biomaterials Science and Technology, TechMed Centre, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, the Netherlands
| | - K Maksymow
- eXcorLab GmbH, Industrie Center Obernburg, Obernburg, Germany
| | - M Rüth
- eXcorLab GmbH, Industrie Center Obernburg, Obernburg, Germany
| | - H D Lemke
- eXcorLab GmbH, Industrie Center Obernburg, Obernburg, Germany
| | - D Stamatialis
- (Bio)artificial organs, Department of Biomaterials Science and Technology, TechMed Centre, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, the Netherlands.
| |
Collapse
|
45
|
Li H, Zeng X, Shi W, Zhang H, Huang S, Zhou R, Qin X. Recovery and purification of potato proteins from potato starch wastewater by hollow fiber separation membrane integrated process. INNOV FOOD SCI EMERG 2020. [DOI: 10.1016/j.ifset.2020.102380] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
46
|
Hollow fiber membranes for long-term hemodialysis based on polyethersulfone-SlipSkin™ polymer blends. J Memb Sci 2020. [DOI: 10.1016/j.memsci.2020.118068] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
47
|
Chen Z, Mahmud S, Cai L, He Z, Yang Y, Zhang L, Zhao S, Xiong Z. Hierarchical poly(vinylidene fluoride)/active carbon composite membrane with self-confining functional carbon nanotube layer for intractable wastewater remediation. J Memb Sci 2020. [DOI: 10.1016/j.memsci.2020.118041] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
48
|
Polysulfone/amino-silanized poly(methyl methacrylate) dual layer hollow fiber membrane for uremic toxin separation. Sep Purif Technol 2020. [DOI: 10.1016/j.seppur.2019.116216] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
49
|
Shan L, Sun Y, Shan F, Li L, Xu ZP. Recent advances in heparinization of polymeric membranes for enhanced continuous blood purification. J Mater Chem B 2020; 8:878-894. [PMID: 31956883 DOI: 10.1039/c9tb02515d] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Continuous blood purification technology such as hemodiafiltration has been used worldwide for saving patients suffering from severe diseases or organ function failure, especially in the intensive care unit and emergency setting. The filters as core devices are commonly made of polymer materials as hollow fiber membranes. However, the membrane is often inductively blocked by blood clot formation due to its interactions with blood components. Heparin is the anticoagulant often used in clinical practice for anti-coagulation. Recently, heparin is also employed to modify the hollow fiber membranes either chemically or physically to improve the filtration performance. This review summarizes recent advances in methodology for surface heparinization of such hollow fiber membranes, and their filtration performance improvement. The review also provides expert opinions for further research in this rapidly expanding field.
Collapse
Affiliation(s)
- Liang Shan
- Intensive Care Unit, The Affiliated Hospital of Qingdao University, Qingdao 266003, China and Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane 4072, Australia.
| | - Yunbo Sun
- Intensive Care Unit, The Affiliated Hospital of Qingdao University, Qingdao 266003, China
| | - Feng Shan
- Intensive Care Unit, The Affiliated Hospital of Qingdao University, Qingdao 266003, China
| | - Li Li
- Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane 4072, Australia.
| | - Zhi Ping Xu
- Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane 4072, Australia.
| |
Collapse
|
50
|
Yu HL, Fu CC, Hsiao YS, Chien CC, Juang RS. Preparation of porous phosphine oxide-incorporated polymer membranes for selective removal of p-cresol from simulated serum: A preliminary study. J Taiwan Inst Chem Eng 2020. [DOI: 10.1016/j.jtice.2019.11.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|