1
|
de Moraes Marcondes G, Paretsis NF, da Silva DCB, de Souza AF, Rego MAF, da Silva GCM, Fülber J, Corrêa L, Friedrichsdorf SP, de Guzzi Plepis AM, da Conceição Amaro Martins V, Cortopassi SRG, do Valle De Zoppa AL. Bone Tissue Engineering With Chitosan, Carbon Nanotubes, and Hydroxyapatite Biomaterials Enriched With Mesenchymal Stem Cells: A Radiographic and Histological Evaluation in a Sheep Model Undergoing Ostectomy (Bone Tissue Engineering in a Sheep Model). J Biomed Mater Res B Appl Biomater 2025; 113:e35523. [PMID: 39704030 DOI: 10.1002/jbm.b.35523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 10/30/2024] [Accepted: 12/04/2024] [Indexed: 12/21/2024]
Abstract
Comminuted fractures associated with tissue loss can adversely affect bone regeneration. Biomaterials enriched with mesenchymal stem cells (MSCs) employed for supporting osteosynthesis and potentiating osteoconduction are necessary to fill these bone defects. Natural compound biomaterials, similar to bone tissue, have been extensively tested in animal models for clinical use. Bone tissue engineering studies have used critical-size defects in ovine tibia monitored by imaging and histological examinations to evaluate the regenerative process. This study aimed to monitor the regenerative process in ovine tibial defects with or without chitosan, carbon nanotubes, or hydroxyapatite biomaterials, enriched or not enriched with MSCs. A 3-cm ostectomy was performed in 18 female Suffolk sheep. A 10-hole 4.5 mm narrow locking compression plate was used for osteosynthesis. The animals were randomly divided into three groups (n = 6): control (CON); defects filled with chitosan, carbon nanotubes, and hydroxyapatite biomaterial (BIO); and the same biomaterial enriched with bone marrow MSCs (BIO + CELL). The animals were evaluated monthly using radiographic examinations until 90 postoperative days, when they were euthanized. The limbs were subjected to micro-computed tomography (micro-CT), and bone specimens were subjected to histological evaluations. The radiographic examinations revealed construction stability without plate deviation, fracture, or bone lysis. Micro-CT evaluation demonstrated a difference in bone microarchitecture between the CON and biomaterial treatment groups (BIO and BIO + CELL). In the histological evaluations, the CON group did not demonstrate bone formation, and in the treatment groups (BIO and BIO + CELL), biocompatibility with sheep tissue was noted, and bone formation with trabeculae interspersed with remnants of the biomaterial was observed, with no differences between the groups. In conclusion, biomaterials present osteoconduction with beneficial characteristics for filling bone-lost fractures, and MSCs did not interfere with bone formation.
Collapse
Affiliation(s)
- Geissiane de Moraes Marcondes
- Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo (FMVZ-USP), São Paulo, SP, Brazil
| | - Nicole Fidalgo Paretsis
- Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo (FMVZ-USP), São Paulo, SP, Brazil
| | | | - Anderson Fernando de Souza
- Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo (FMVZ-USP), São Paulo, SP, Brazil
| | - Mario Antônio Ferraro Rego
- Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo (FMVZ-USP), São Paulo, SP, Brazil
| | | | - Joice Fülber
- Department of Internal Medicine, School of Veterinary Medicine and Animal Science, University of São Paulo (FMVZ-USP), São Paulo, SP, Brazil
| | - Luciana Corrêa
- Department of Stomatology, School of Dentistry, University of São Paulo (FO-USP), São Paulo, SP, Brazil
| | | | - Ana Maria de Guzzi Plepis
- Department of Chemistry and Molecular Physics, Institute of Chemistry of São Carlos, University of São Paulo (IQSC-USP), São Carlos, SP, Brazil
| | - Virginia da Conceição Amaro Martins
- Department of Chemistry and Molecular Physics, Institute of Chemistry of São Carlos, University of São Paulo (IQSC-USP), São Carlos, SP, Brazil
| | - Silvia Renata Gaido Cortopassi
- Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo (FMVZ-USP), São Paulo, SP, Brazil
| | - André Luis do Valle De Zoppa
- Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo (FMVZ-USP), São Paulo, SP, Brazil
| |
Collapse
|
2
|
Pazhamannil RV, Alkhedher M. Advances in additive manufacturing for bone tissue engineering: materials, design strategies, and applications. Biomed Mater 2024; 20:012002. [PMID: 39662052 DOI: 10.1088/1748-605x/ad9dce] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Accepted: 12/11/2024] [Indexed: 12/13/2024]
Abstract
The growing annual demand for bone grafts and artificial implants emphasizes the need for effective solutions to repair or replace injured bones. Additive manufacturing technology offers unique merits for advancing bone tissue engineering (BTE), enabling the creation of scaffolds and implants with customized shapes and designs, interconnected architecture, controlled mechanical properties and compositions, and broadening its range of applications. It overcomes the limitations of traditional manufacturing methods such as electrospinning, salt leaching, freeze drying, solvent casting etc. This review highlights additive manufacturing technologies and their applications in BTE, as well as materials and scaffold architectures to widen the potential of the biomedical sector. The selection of optimal printing methods for BTE requires careful consideration of the advantages and disadvantages against the needs for degradation, strength, and biocompatibility. Material extrusion and powder bed fusion techniques are the most widely used additive manufacturing processes in BTE. The comprehensive review also revealed that parametric designs such as triply periodic minimal surface (TPMS) and Voronoi hold better characteristics for their application in BTE. Voronoi designs exhibit exceptional randomness whereas TPMS structures feature high permeability with continuous surfaces. Topology optimized and gradient models exhibited superior physical and mechanical properties compared to uniform lattices. Future research should focus on the development of novel biomaterials, multi-material printing, assessing long-term impacts, and enhancing 3D printing technologies.
Collapse
Affiliation(s)
- Ribin Varghese Pazhamannil
- Mechanical and Industrial Engineering Department, Abu Dhabi University, PO 59911 Abu Dhabi, United Arab Emirates
| | - Mohammad Alkhedher
- Mechanical and Industrial Engineering Department, Abu Dhabi University, PO 59911 Abu Dhabi, United Arab Emirates
| |
Collapse
|
3
|
Vahidi M, Rizkalla AS, Mequanint K. Extracellular Matrix-Surrogate Advanced Functional Composite Biomaterials for Tissue Repair and Regeneration. Adv Healthc Mater 2024; 13:e2401218. [PMID: 39036851 DOI: 10.1002/adhm.202401218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 06/13/2024] [Indexed: 07/23/2024]
Abstract
Native tissues, comprising multiple cell types and extracellular matrix components, are inherently composites. Mimicking the intricate structure, functionality, and dynamic properties of native composite tissues represents a significant frontier in biomaterials science and tissue engineering research. Biomimetic composite biomaterials combine the benefits of different components, such as polymers, ceramics, metals, and biomolecules, to create tissue-template materials that closely simulate the structure and functionality of native tissues. While the design of composite biomaterials and their in vitro testing are frequently reviewed, there is a considerable gap in whole animal studies that provides insight into the progress toward clinical translation. Herein, we provide an insightful critical review of advanced composite biomaterials applicable in several tissues. The incorporation of bioactive cues and signaling molecules into composite biomaterials to mimic the native microenvironment is discussed. Strategies for the spatiotemporal release of growth factors, cytokines, and extracellular matrix proteins are elucidated, highlighting their role in guiding cellular behavior, promoting tissue regeneration, and modulating immune responses. Advanced composite biomaterials design challenges, such as achieving optimal mechanical properties, improving long-term stability, and integrating multifunctionality into composite biomaterials and future directions, are discussed. We believe that this manuscript provides the reader with a timely perspective on composite biomaterials.
Collapse
Affiliation(s)
- Milad Vahidi
- Department of Chemical and Biochemical Engineering, The University of Western Ontario, London, N6A5B9, Canada
| | - Amin S Rizkalla
- Department of Chemical and Biochemical Engineering, The University of Western Ontario, London, N6A5B9, Canada
- School of Biomedical Engineering, The University of Western Ontario, London, N6A5B9, Canada
| | - Kibret Mequanint
- Department of Chemical and Biochemical Engineering, The University of Western Ontario, London, N6A5B9, Canada
- School of Biomedical Engineering, The University of Western Ontario, London, N6A5B9, Canada
| |
Collapse
|
4
|
Shevtsov M, Pitkin E, Combs SE, Meulen GVD, Preucil C, Pitkin M. Comparison In Vitro Study on the Interface between Skin and Bone Cell Cultures and Microporous Titanium Samples Manufactured with 3D Printing Technology Versus Sintered Samples. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:1484. [PMID: 39330641 PMCID: PMC11434446 DOI: 10.3390/nano14181484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2024] [Revised: 09/05/2024] [Accepted: 09/06/2024] [Indexed: 09/28/2024]
Abstract
Percutaneous implants osseointegrated into the residuum of a person with limb amputation need to provide mechanical stability and protection against infections. Although significant progress has been made in the biointegration of percutaneous implants, the problem of forming a reliable natural barrier at the level of the surface of the implant and the skin and bone tissues remains unresolved. The use of a microporous implant structure incorporated into the Skin and Bone Integrated Pylon (SBIP) should address the issue by allowing soft and bone tissues to grow directly into the implant structure itself, which, in turn, should form a reliable barrier to infections and support strong osseointegration. To evaluate biological interactions between dermal fibroblasts and MC3T3-E1 osteoblasts in vitro, small titanium discs (with varying pore sizes and volume fractions to achieve deep porosity) were fabricated via 3D printing and sintering. The cell viability MTT assay demonstrated low cytotoxicity for cells co-cultured in the pores of the 3D-printed and sintered Ti samples during the 14-day follow-up period. A subsequent Quantitative Real-Time Polymerase Chain Reaction (RT-PCR) analysis of the relative gene expression of biomarkers that are associated with cell adhesion (α2, α5, αV, and β1 integrins) and extracellular matrix components (fibronectin, vitronectin, type I collagen) demonstrated that micropore sizes ranging from 200 to 500 µm of the 3D printed and sintered Ti discs were favorable for dermal fibroblast adhesion. For example, for representative 3D-printed Ti sample S6 at 72 h the values were 4.71 ± 0.08 (α2 integrin), 4.96 ± 0.08 (α5 integrin), 4.71 ± 0.08 (αV integrin), and 1.87 ± 0.12 (β1 integrin). In contrast, Ti discs with pore sizes ranging from 400 to 800 µm demonstrated the best results (in terms of marker expression related to osteogenic differentiation, including osteopontin, osteonectin, osteocalcin, TGF-β1, and SMAD4) for MC3T3-E1 cells. For example, for the representative 3D sample S4 on day 14, the marker levels were 11.19 ± 0.77 (osteopontin), 7.15 ± 0.29 (osteonectin), and 6.08 ± 0.12 (osteocalcin), while for sintered samples the levels of markers constituted 5.85 ± 0.4 (osteopontin), 4.45 ± 0.36 (osteonectin), and 4.46 ± 0.3 (osteocalcin). In conclusion, the data obtained show the high biointegrative properties of porous titanium structures, while the ability to implement several pore options in one structure using 3D printing makes it possible to create personalized implants for the best one-time integration with both skin and bone tissues.
Collapse
Affiliation(s)
- Maxim Shevtsov
- Department of Radiation Oncology, Technische Universität München (TUM), Klinikum Rechts der Isar, Ismaninger Str. 22, 81675 Munich, Germany
- Laboratory of Biomedical Nanotechnologies, Institute of Cytology of the Russian Academy of Sciences (RAS), 194064 Saint Petersburg, Russia
- Personalized Medicine Centre, Almazov National Medical Research Centre, 2 Akkuratova Str., 197341 Saint Petersburg, Russia
| | - Emil Pitkin
- Department of Statistics and Data Science, The Wharton School, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Stephanie E Combs
- Department of Radiation Oncology, Technische Universität München (TUM), Klinikum Rechts der Isar, Ismaninger Str. 22, 81675 Munich, Germany
| | | | | | - Mark Pitkin
- Department of Orthopaedics and Rehabilitation Medicine, Tufts University School of Medicine, Boston, MA 02111, USA
- Poly-Orth International, Sharon, MA 02067, USA
| |
Collapse
|
5
|
Longhitano GA, Chiarelli M, Prada D, Zavaglia CADC, Maciel Filho R. Personalized lattice-structured prosthesis as a graftless solution for mandible reconstruction and prosthetic restoration: A finite element analysis. J Mech Behav Biomed Mater 2024; 152:106460. [PMID: 38340477 DOI: 10.1016/j.jmbbm.2024.106460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 02/01/2024] [Accepted: 02/05/2024] [Indexed: 02/12/2024]
Abstract
Oral cavity tumors are a prevalent cause of mandible reconstruction surgeries. The mandible is vital for functions like oralization, respiration, mastication, and deglutition. Current mandible reconstruction methods have low success rates due to complications like plate fracture or exposure, infections, and screw loosening. Autogenous bone grafts are commonly used but carry the risk of donor region morbidity. Despite technological advances, an ideal solution for mandible reconstruction remains elusive. Additive manufacturing in medicine offers personalized prosthetics from patient-specific medical images, allowing for the creation of porous structures with tailored mechanical properties that mimic bone properties. This study compared a commercial reconstruction plate with a lattice-structured personalized prosthesis under different biting and osseointegration conditions using Finite Element Analysis. Patient-specific images were obtained from an individual who underwent mandible reconstruction with a commercial plate and suffered from plate fracture by fatigue after 26 months. Compared to the commercial plate, the maximum von Mises equivalent stress was significantly lowered for the personalized prosthesis, hindering a possible fatigue fracture. The equivalent von Mises strains found in bone were within bone maintenance and remodeling intervals. This work introduces a design that doesn't require grafts for large bone defects and allows for dental prosthesis addition without the need for implants.
Collapse
Affiliation(s)
- Guilherme Arthur Longhitano
- National Institute of Biofabrication (INCT-BIOFABRIS), Campinas, 13083-852, Brazil; Faculdade de Engenharia Química, Universidade Estadual de Campinas (UNICAMP), Campinas, 13083-852, Brazil; 3D Printing Open Lab, Center for Information Technology Renato Archer, Campinas, 13069-901, Brazil; Faculdade de Engenharia Mecânica, Universidade Estadual de Campinas (UNICAMP), Campinas, 13083-860, Brazil.
| | - Murillo Chiarelli
- Oral and Maxillofacial Surgeon, Secretaria de Estado da Saúde, Hospital Governador Celso Ramos/SMS, Florianópolis, 88015-270, Brazil
| | - Daniel Prada
- Faculdade de Engenharia Mecânica, Universidade Estadual de Campinas (UNICAMP), Campinas, 13083-860, Brazil
| | - Cecília Amélia de Carvalho Zavaglia
- National Institute of Biofabrication (INCT-BIOFABRIS), Campinas, 13083-852, Brazil; Faculdade de Engenharia Mecânica, Universidade Estadual de Campinas (UNICAMP), Campinas, 13083-860, Brazil
| | - Rubens Maciel Filho
- National Institute of Biofabrication (INCT-BIOFABRIS), Campinas, 13083-852, Brazil; Faculdade de Engenharia Química, Universidade Estadual de Campinas (UNICAMP), Campinas, 13083-852, Brazil
| |
Collapse
|
6
|
Honda S, Fujibayashi S, Shimizu T, Yamaguchi S, Okuzu Y, Takaoka Y, Masuda S, Takemoto M, Kawai T, Otsuki B, Goto K, Matsuda S. Strontium-loaded 3D intramedullary nail titanium implant for critical-sized femoral defect in rabbits. J Biomed Mater Res B Appl Biomater 2024; 112:e35393. [PMID: 38385959 DOI: 10.1002/jbm.b.35393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 02/01/2024] [Accepted: 02/08/2024] [Indexed: 02/23/2024]
Abstract
The treatment of critical-sized bone defects has long been a major problem for surgeons. In this study, an intramedullary nail shaped three-dimensional (3D)-printed porous titanium implant that is capable of releasing strontium ions was developed through a simple and cost-effective surface modification technique. The feasibility of this implant as a stand-alone solution was evaluated using a rabbit's segmental diaphyseal as a defect model. The strontium-loaded implant exhibited a favorable environment for cell adhesion, and mechanical properties that were commensurate with those of a rabbit's cortical bone. Radiographic, biomechanical, and histological analyses revealed a significantly higher amount of bone ingrowth and superior bone-bonding strength in the strontium-loaded implant when compared to an untreated porous titanium implant. Furthermore, one-year histological observations revealed that the strontium-loaded implant preserved the native-like diaphyseal bone structure without failure. These findings suggest that strontium-releasing 3D-printed titanium implants have the clinical potential to induce the early and efficient repair of critical-sized, load-bearing bone defects.
Collapse
Affiliation(s)
- Shintaro Honda
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Shunsuke Fujibayashi
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Takayoshi Shimizu
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Seiji Yamaguchi
- Department of Biomedical Sciences, College of Life and Health Sciences, Chubu University, Aichi, Japan
| | - Yaichiro Okuzu
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Yusuke Takaoka
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Soichiro Masuda
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Mitsuru Takemoto
- Department of Orthopaedic Surgery, Kyoto City Hospital, Kyoto, Japan
| | - Toshiyuki Kawai
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Bungo Otsuki
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Koji Goto
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Shuichi Matsuda
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan
| |
Collapse
|
7
|
Jin X, Xie D, Zhang Z, Liu A, Wang M, Dai J, Wang X, Deng H, Liang Y, Zhao Y, Wen P, Li Y. In vitro and in vivo studies on biodegradable Zn porous scaffolds with a drug-loaded coating for the treatment of infected bone defect. Mater Today Bio 2024; 24:100885. [PMID: 38169782 PMCID: PMC10758886 DOI: 10.1016/j.mtbio.2023.100885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/17/2023] [Accepted: 11/27/2023] [Indexed: 01/05/2024] Open
Abstract
Additively manufactured biodegradable zinc (Zn) scaffolds have great potential to repair infected bone defects due to their osteogenic and antibacterial properties. However, the enhancement of antibacterial properties depends on a high concentration of dissolved Zn2+, which in return deteriorates osteogenic activity. In this study, a vancomycin (Van)-loaded polydopamine (PDA) coating was prepared on pure Zn porous scaffolds to solve the above dilemma. Compared with pure Zn scaffolds according to comprehensive in vitro tests, the PDA coating resulted in a slow degradation and inhibited the excessive release of Zn2+ at the early stage, thus improving cytocompatibility and osteogenic activity. Meanwhile, the addition of Van drug substantially suppressed the attachment and proliferation of S. aureus and E. coli bacterial. Furthermore, in vivo implantation confirmed the simultaneously improved osteogenic and antibacterial functions by using the pure Zn scaffolds with Van-loaded PDA coating. Therefore, it is promising to employ biodegradable Zn porous scaffolds with the proposed drug-loaded coating for the treatment of infected bone defects.
Collapse
Affiliation(s)
- Xiang Jin
- Postgraduate Training Base, Jinzhou Medical University and The Fourth Medical Centre, Chinese PLA General Hospital, Beijing, 10048, China
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Dongxu Xie
- State Key Laboratory of Tribology in Advanced Equipment, Beijing, 100084, China
- Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China
| | - Zhenbao Zhang
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Aobo Liu
- State Key Laboratory of Tribology in Advanced Equipment, Beijing, 100084, China
- Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China
| | - Menglin Wang
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Jiabao Dai
- State Key Laboratory of Tribology in Advanced Equipment, Beijing, 100084, China
- Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China
| | - Xuan Wang
- Postgraduate Training Base, Jinzhou Medical University and The Fourth Medical Centre, Chinese PLA General Hospital, Beijing, 10048, China
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Huanze Deng
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Yijie Liang
- Postgraduate Training Base, Jinzhou Medical University and The Fourth Medical Centre, Chinese PLA General Hospital, Beijing, 10048, China
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| | - Yantao Zhao
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
- Senior Department of Orthopedics, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
- Beijing Engineering Research Center of Orthopedics Implants, Beijing, 100048, China
| | - Peng Wen
- State Key Laboratory of Tribology in Advanced Equipment, Beijing, 100084, China
- Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China
| | - Yanfeng Li
- Postgraduate Training Base, Jinzhou Medical University and The Fourth Medical Centre, Chinese PLA General Hospital, Beijing, 10048, China
- Department of Stomatology, The Fourth Medical Centre, PLA General Hospital, Beijing, 100048, China
| |
Collapse
|
8
|
Kiselevskiy MV, Anisimova NY, Kapustin AV, Ryzhkin AA, Kuznetsova DN, Polyakova VV, Enikeev NA. Development of Bioactive Scaffolds for Orthopedic Applications by Designing Additively Manufactured Titanium Porous Structures: A Critical Review. Biomimetics (Basel) 2023; 8:546. [PMID: 37999187 PMCID: PMC10669447 DOI: 10.3390/biomimetics8070546] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 11/01/2023] [Accepted: 11/09/2023] [Indexed: 11/25/2023] Open
Abstract
We overview recent findings achieved in the field of model-driven development of additively manufactured porous materials for the development of a new generation of bioactive implants for orthopedic applications. Porous structures produced from biocompatible titanium alloys using selective laser melting can present a promising material to design scaffolds with regulated mechanical properties and with the capacity to be loaded with pharmaceutical products. Adjusting pore geometry, one could control elastic modulus and strength/fatigue properties of the engineered structures to be compatible with bone tissues, thus preventing the stress shield effect when replacing a diseased bone fragment. Adsorption of medicals by internal spaces would make it possible to emit the antibiotic and anti-tumor agents into surrounding tissues. The developed internal porosity and surface roughness can provide the desired vascularization and osteointegration. We critically analyze the recent advances in the field featuring model design approaches, virtual testing of the designed structures, capabilities of additive printing of porous structures, biomedical issues of the engineered scaffolds, and so on. Special attention is paid to highlighting the actual problems in the field and the ways of their solutions.
Collapse
Affiliation(s)
- Mikhail V. Kiselevskiy
- N.N. Blokhin National Medical Research Center of Oncology (N.N. Blokhin NMRCO), Ministry of Health of the Russian Federation, 115478 Moscow, Russia;
- Department of Casting Technologies and Artistic Processing of Materials, National University of Science and Technology “MISIS”, 119049 Moscow, Russia
| | - Natalia Yu. Anisimova
- N.N. Blokhin National Medical Research Center of Oncology (N.N. Blokhin NMRCO), Ministry of Health of the Russian Federation, 115478 Moscow, Russia;
- Department of Casting Technologies and Artistic Processing of Materials, National University of Science and Technology “MISIS”, 119049 Moscow, Russia
| | - Alexei V. Kapustin
- Laboratory for Metals and Alloys under Extreme Impacts, Ufa University of Science and Technology, 450076 Ufa, Russia (A.A.R.); (D.N.K.); (V.V.P.); (N.A.E.)
| | - Alexander A. Ryzhkin
- Laboratory for Metals and Alloys under Extreme Impacts, Ufa University of Science and Technology, 450076 Ufa, Russia (A.A.R.); (D.N.K.); (V.V.P.); (N.A.E.)
| | - Daria N. Kuznetsova
- Laboratory for Metals and Alloys under Extreme Impacts, Ufa University of Science and Technology, 450076 Ufa, Russia (A.A.R.); (D.N.K.); (V.V.P.); (N.A.E.)
| | - Veronika V. Polyakova
- Laboratory for Metals and Alloys under Extreme Impacts, Ufa University of Science and Technology, 450076 Ufa, Russia (A.A.R.); (D.N.K.); (V.V.P.); (N.A.E.)
| | - Nariman A. Enikeev
- Laboratory for Metals and Alloys under Extreme Impacts, Ufa University of Science and Technology, 450076 Ufa, Russia (A.A.R.); (D.N.K.); (V.V.P.); (N.A.E.)
- Laboratory for Dynamics and Extreme Characteristics of Promising Nanostructured Materials, Saint Petersburg State University, 199034 St. Petersburg, Russia
| |
Collapse
|
9
|
Shang P, Ma B, Hou G, Zhang Y, Cui L, Song W, Liu Y. A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement. J Orthop Surg Res 2023; 18:828. [PMID: 37924130 PMCID: PMC10623881 DOI: 10.1186/s13018-023-04310-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 10/22/2023] [Indexed: 11/06/2023] Open
Abstract
BACKGROUND Prosthesis subsidence and mechanical failure were considered significant threats after vertebral body replacement during the long-term follow-up. Therefore, improving and optimizing the structure of vertebral substitutes for exceptional performance has become a pivotal challenge in spinal reconstruction. METHODS The study aimed to develop a novel artificial vertebral implant (AVI) with triply periodic minimal surface Gyroid porous structures to enhance the safety and stability of prostheses. The biomechanical performance of AVIs under different loading conditions was analyzed using the finite element method. These implants were fabricated using selective laser melting technology and evaluated through static compression and subsidence experiments. RESULTS The results demonstrated that the peak stress in the Gyroid porous AVI was consistently lower than that in the traditional porous AVI under all loading conditions, with a maximum reduction of 73.4%. Additionally, it effectively reduced peak stress at the bone-implant interface of the vertebrae. Static compression experiments demonstrated that the Gyroid porous AVI was about 1.63 times to traditional porous AVI in terms of the maximum compression load, indicating that Gyroid porous AVI could meet the safety requirement. Furthermore, static subsidence experiments revealed that the subsidence tendency of Gyroid porous AVI in polyurethane foam (simulated cancellous bone) was approximately 15.7% lower than that of traditional porous AVI. CONCLUSIONS The Gyroid porous AVI exhibited higher compressive strength and lower subsidence tendency than the strut-based traditional porous AVI, indicating it may be a promising substitute for spinal reconstruction.
Collapse
Affiliation(s)
- Peng Shang
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China.
| | - Benyuan Ma
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Guanghui Hou
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Yihai Zhang
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Lunxu Cui
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Wanzhen Song
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Yancheng Liu
- Department of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China.
| |
Collapse
|
10
|
Lee SS, Du X, Smit T, Bissacco EG, Seiler D, de Wild M, Ferguson SJ. 3D-printed LEGO®-inspired titanium scaffolds for patient-specific regenerative medicine. BIOMATERIALS ADVANCES 2023; 154:213617. [PMID: 37678088 DOI: 10.1016/j.bioadv.2023.213617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 08/08/2023] [Accepted: 09/02/2023] [Indexed: 09/09/2023]
Abstract
Despite the recent advances in 3D-printing, it is often difficult to fabricate implants that optimally fit a defect size or shape. There are some approaches to resolve this issue, such as patient-specific implant/scaffold designs based on CT images of the patients, however, this process is labor-intensive and costly. Especially in developing countries, affordable treatment options are required, while still not excluding these patient groups from potential material and manufacturing advances. Here, a selective laser melting (SLM) 3D-printing strategy was used to fabricate a hierarchical, LEGO®-inspired Assemblable Titanium Scaffold (ATS) system, which can be manually assembled in any shape or size with ease. A surgeon can quickly create a scaffold that would fit to the defect right before the implantation during the surgery. Additionally, the direct inclusion of micro- and macroporous structures via 3D-printing, as well as a double acid-etched surface treatment (ST) in the ATS, ensure biocompatibility, sufficient nutrient flow, cell migration and enhanced osteogenesis. Three different structures were designed (non-porous:NP, semi-porous:SP, ultra-porous:UP), 3D-printed with the SLM technique and then surface treated for the ST groups. After analyzing characteristics of the ATS such as printing quality, surface roughness and interconnected porosity, mechanical testing and finite element analysis (FEA) demonstrated that individual and stacked ATS have sufficient mechanical properties to withstand loading in a physiological system. All ATS showed high cell viability, and the SP and UP groups demonstrated enhanced cell proliferation rates compared to the NP group. Furthermore, we also verified that cells were well-attached and spread on the porous structures and successful cell migration between the ATS units was seen in the case of assemblies. The UP and SP groups exhibited higher calcium deposition and RT-qPCR proved higher osteogenic gene expression compared to NP group. Finally, we demonstrate a number of possible medical applications that reveal the potential of the ATS through assembly.
Collapse
Affiliation(s)
- Seunghun S Lee
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.
| | - Xiaoyu Du
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Thijs Smit
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Elisa G Bissacco
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Daniel Seiler
- Institute for Medical Engineering and Medical Informatics IM(2), FHNW, Muttenz, Switzerland
| | - Michael de Wild
- Institute for Medical Engineering and Medical Informatics IM(2), FHNW, Muttenz, Switzerland
| | - Stephen J Ferguson
- Institute for Biomechanics, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
11
|
Ivanovski S, Breik O, Carluccio D, Alayan J, Staples R, Vaquette C. 3D printing for bone regeneration: challenges and opportunities for achieving predictability. Periodontol 2000 2023; 93:358-384. [PMID: 37823472 DOI: 10.1111/prd.12525] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 07/18/2023] [Accepted: 08/26/2023] [Indexed: 10/13/2023]
Abstract
3D printing offers attractive opportunities for large-volume bone regeneration in the oro-dental and craniofacial regions. This is enabled by the development of CAD-CAM technologies that support the design and manufacturing of anatomically accurate meshes and scaffolds. This review describes the main 3D-printing technologies utilized for the fabrication of these patient-matched devices, and reports on their pre-clinical and clinical performance including the occurrence of complications for vertical bone augmentation and craniofacial applications. Furthermore, the regulatory pathway for approval of these devices is discussed, highlighting the main hurdles and obstacles. Finally, the review elaborates on a variety of strategies for increasing bone regeneration capacity and explores the future of 4D bioprinting and biodegradable metal 3D printing.
Collapse
Affiliation(s)
- Saso Ivanovski
- School of Dentistry, Centre for Orofacial Regeneration, Reconstruction and Rehabilitation (COR3), The University of Queensland, Queensland, Herston, Australia
| | - Omar Breik
- Herston Biofabrication Institute, Metro North Hospital and Health Service, Brisbane, Queensland, Australia
| | - Danilo Carluccio
- Herston Biofabrication Institute, Metro North Hospital and Health Service, Brisbane, Queensland, Australia
| | - Jamil Alayan
- School of Dentistry, Centre for Orofacial Regeneration, Reconstruction and Rehabilitation (COR3), The University of Queensland, Queensland, Herston, Australia
| | - Ruben Staples
- School of Dentistry, Centre for Orofacial Regeneration, Reconstruction and Rehabilitation (COR3), The University of Queensland, Queensland, Herston, Australia
| | - Cedryck Vaquette
- School of Dentistry, Centre for Orofacial Regeneration, Reconstruction and Rehabilitation (COR3), The University of Queensland, Queensland, Herston, Australia
- Herston Biofabrication Institute, Metro North Hospital and Health Service, Brisbane, Queensland, Australia
| |
Collapse
|
12
|
Liu A, Lu Y, Dai J, Wen P, Xia D, Zheng Y. Mechanical properties, in vitro biodegradable behavior, biocompatibility and osteogenic ability of additively manufactured Zn-0.8Li-0.1Mg alloy scaffolds. BIOMATERIALS ADVANCES 2023; 153:213571. [PMID: 37562158 DOI: 10.1016/j.bioadv.2023.213571] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 06/29/2023] [Accepted: 07/25/2023] [Indexed: 08/12/2023]
Abstract
Alloying and structural design provide flexibility to modulate performance of biodegradable porous implants manufactured by laser powder bed fusion (L-PBF). Herein, bulk Zn-0.8Li-0.1Mg was first fabricated to indicate the influence of the ternary alloy system on strengthening effect. Porous scaffolds with different porosities, including 60 % (P60), 70 % (P70) and 80 % (P80), were designed and fabricated to study the influence of porosity on mechanical properties, in vitro degradation behavior, biocompatibility and osteogenic ability. Pure Zn (Zn-P70) scaffolds with a porosity of 70 % were utilized for the comparison. The results showed Zn-0.8Li-0.1Mg bulks had an ultimate tensile strength of 460.78 ± 5.79 MPa, which was more than 3 times that of pure Zn ones and was the highest value ever reported for Zn alloys fabricated by L-PBF. The compressive strength (CS) and elastic modulus (E) of scaffolds decreased with increasing porosities. The CS of P70 scaffolds was 24.59 MPa, more than 2 times that of Zn-P70. The weight loss of scaffolds during in vitro immersion increased with increasing porosities. Compared with Zn-P70, a lower weight loss, better biocompatibility and improved osteogenic ability were observed for P70 scaffolds. P70 scaffolds also exhibited the best biocompatibility and osteogenic ability among all the used porosities. Influence mechanism of alloying elements and structural porosities on mechanical behaviors, in vitro biodegradation behavior, biocompatibility and osteogenic ability of scaffolds were discussed using finite element analysis and the characterization of degradation products. The results indicated that the proper design of alloying and porosity made Zn-0.8Li-0.1Mg scaffolds promising for biodegradable applications.
Collapse
Affiliation(s)
- Aobo Liu
- State Key Laboratory of Tribology in Advanced Equipment, Tsinghua University, Beijing 100084, China; Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Yupu Lu
- Department of Dental Materials, Peking University School and Hospital of Stomatology, National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing 100081, China
| | - Jiabao Dai
- State Key Laboratory of Tribology in Advanced Equipment, Tsinghua University, Beijing 100084, China; Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Peng Wen
- State Key Laboratory of Tribology in Advanced Equipment, Tsinghua University, Beijing 100084, China; Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China.
| | - Dandan Xia
- Department of Dental Materials, Peking University School and Hospital of Stomatology, National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing 100081, China.
| | - Yufeng Zheng
- School of Materials Science and Engineering, Peking University, Beijing 100871, China..
| |
Collapse
|
13
|
Asbai-Ghoudan R, Nasello G, Pérez MÁ, Verbruggen SW, Ruiz de Galarreta S, Rodriguez-Florez N. In silico assessment of the bone regeneration potential of complex porous scaffolds. Comput Biol Med 2023; 165:107381. [PMID: 37611419 DOI: 10.1016/j.compbiomed.2023.107381] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 07/21/2023] [Accepted: 08/14/2023] [Indexed: 08/25/2023]
Abstract
Mechanical environment plays a crucial role in regulating bone regeneration in bone defects. Assessing the mechanobiological behavior of patient-specific orthopedic scaffolds in-silico could help guide optimal scaffold designs, as well as intra- and post-operative strategies to enhance bone regeneration and improve implant longevity. Additively manufactured porous scaffolds, and specifically triply periodic minimal surfaces (TPMS), have shown promising structural properties to act as bone substitutes, yet their ability to induce mechanobiologially-driven bone regeneration has not been elucidated. The aim of this study is to i) explore the bone regeneration potential of TPMS scaffolds made of different stiffness biocompatible materials, to ii) analyze the influence of pre-seeding the scaffolds and increasing the post-operative resting period, and to iii) assess the influence of patient-specific parameters, such as age and mechanosensitivity, on outcomes. To perform this study, an in silico model of a goat tibia is used. The bone ingrowth within the scaffold pores was simulated with a mechano-driven model of bone regeneration. Results showed that the scaffold's architectural properties affect cellular diffusion and strain distribution, resulting in variations in the regenerated bone volume and distribution. The softer material improved the bone ingrowth. An initial resting period improved the bone ingrowth but not enough to reach the scaffold's core. However, this was achieved with the implantation of a pre-seeded scaffold. Physiological parameters like age and health of the patient also influence the bone regeneration outcome, though to a lesser extent than the scaffold design. This analysis demonstrates the importance of the scaffold's geometry and its material, and highlights the potential of using mechanobiological patient-specific models in the design process for bone substitutes.
Collapse
Affiliation(s)
- Reduan Asbai-Ghoudan
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain.
| | - Gabriele Nasello
- Prometheus Division of Skeletal Tissue Engineering, KU Leuven, O&N1, Herestraat 49, PB 813, 3000, Leuven, Belgium
| | - María Ángeles Pérez
- Multiscale in Mechanical and Biological Engineering, Instituto de Investigación en Ingeniería de Aragón (I3A), Instituto de Investigación Sanitaria Aragón (IIS Aragón), University of Zaragoza, 50018, Zaragoza, Spain
| | - Stefaan W Verbruggen
- Centre for Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, E1 4NS, UK; Department of Mechanical Engineering and INSIGNEO Institute for in Silico Medicine, University of Sheffield, Sheffield, S1 3JD, UK
| | - Sergio Ruiz de Galarreta
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain
| | - Naiara Rodriguez-Florez
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain; IKERBASQUE, Basque Foundation for Science, Plaza Euskadi 5, 48009, Bilbao, Spain
| |
Collapse
|
14
|
Williamson T, Ryan S, Buehner U, Sweeney Z, Hill D, Lozanovski B, Kastrati E, Namvar A, Beths T, Shidid D, Blanchard R, Fox K, Leary M, Choong P, Brandt M. Robot-assisted implantation of additively manufactured patient-specific orthopaedic implants: evaluation in a sheep model. Int J Comput Assist Radiol Surg 2023; 18:1783-1793. [PMID: 36859520 PMCID: PMC10497442 DOI: 10.1007/s11548-023-02848-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 01/31/2023] [Indexed: 03/03/2023]
Abstract
PURPOSE Bone tumours must be surgically excised in one piece with a margin of healthy tissue. The unique nature of each bone tumour case is well suited to the use of patient-specific implants, with additive manufacturing allowing production of highly complex geometries. This work represents the first assessment of the combination of surgical robotics and patient-specific additively manufactured implants. METHODS The development and evaluation of a robotic system for bone tumour excision, capable of milling complex osteotomy paths, is described. The developed system was evaluated as part of an animal trial on 24 adult male sheep, in which robotic bone excision of the distal femur was followed by placement of patient-specific implants with operative time evaluated. Assessment of implant placement accuracy was completed based on post-operative CT scans. RESULTS A mean overall implant position error of 1.05 ± 0.53 mm was achieved, in combination with a mean orientation error of 2.38 ± 0.98°. A mean procedure time (from access to implantation, excluding opening and closing) of 89.3 ± 25.25 min was observed, with recorded surgical time between 58 and 133 min, with this approximately evenly divided between robotic (43.9 ± 15.32) and implant-based (45.4 ± 18.97) tasks. CONCLUSIONS This work demonstrates the ability for robotics to achieve repeatable and precise removal of complex bone volumes of the type that would allow en bloc removal of a bone tumour. These robotically created volumes can be precisely filled with additively manufactured patient-specific implants, with minimal gap between cut surface and implant interface.
Collapse
Affiliation(s)
- Tom Williamson
- RMIT Centre for Additive Manufacturing, RMIT University, Melbourne, Australia.
| | - Stewart Ryan
- Translational Research and Animal Clinical Trial Study Group (TRACTS), Faculty of Veterinary and Agricultural Sciences, University of Melbourne, Melbourne, Australia
| | | | - Zac Sweeney
- RMIT Centre for Additive Manufacturing, RMIT University, Melbourne, Australia
- Stryker, Sydney, Australia
| | - Dave Hill
- RMIT Centre for Additive Manufacturing, RMIT University, Melbourne, Australia
| | - Bill Lozanovski
- RMIT Centre for Additive Manufacturing, RMIT University, Melbourne, Australia
| | - Endri Kastrati
- RMIT Centre for Additive Manufacturing, RMIT University, Melbourne, Australia
| | - Arman Namvar
- Department of Surgery, University of Melbourne, Melbourne, Australia
| | - Thierry Beths
- Translational Research and Animal Clinical Trial Study Group (TRACTS), Faculty of Veterinary and Agricultural Sciences, University of Melbourne, Melbourne, Australia
| | - Darpan Shidid
- RMIT Centre for Additive Manufacturing, RMIT University, Melbourne, Australia
| | - Romane Blanchard
- Department of Surgery, University of Melbourne, Melbourne, Australia
- Orthopaedic Department, St Vincent's Hospital, Melbourne, Australia
| | - Kate Fox
- RMIT Centre for Additive Manufacturing, RMIT University, Melbourne, Australia
| | - Martin Leary
- RMIT Centre for Additive Manufacturing, RMIT University, Melbourne, Australia
| | - Peter Choong
- Department of Surgery, University of Melbourne, Melbourne, Australia
- Orthopaedic Department, St Vincent's Hospital, Melbourne, Australia
| | - Milan Brandt
- RMIT Centre for Additive Manufacturing, RMIT University, Melbourne, Australia
| |
Collapse
|
15
|
Alshammari A, Alabdah F, Wang W, Cooper G. Virtual Design of 3D-Printed Bone Tissue Engineered Scaffold Shape Using Mechanobiological Modeling: Relationship of Scaffold Pore Architecture to Bone Tissue Formation. Polymers (Basel) 2023; 15:3918. [PMID: 37835968 PMCID: PMC10575293 DOI: 10.3390/polym15193918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 09/14/2023] [Accepted: 09/26/2023] [Indexed: 10/15/2023] Open
Abstract
Large bone defects are clinically challenging, with up to 15% of these requiring surgical intervention due to non-union. Bone grafts (autographs or allografts) can be used but they have many limitations, meaning that polymer-based bone tissue engineered scaffolds (tissue engineering) are a more promising solution. Clinical translation of scaffolds is still limited but this could be improved by exploring the whole design space using virtual tools such as mechanobiological modeling. In tissue engineering, a significant research effort has been expended on materials and manufacturing but relatively little has been focused on shape. Most scaffolds use regular pore architecture throughout, leaving custom or irregular pore architecture designs unexplored. The aim of this paper is to introduce a virtual design environment for scaffold development and to illustrate its potential by exploring the relationship of pore architecture to bone tissue formation. A virtual design framework has been created utilizing a mechanical stress finite element (FE) model coupled with a cell behavior agent-based model to investigate the mechanobiological relationships of scaffold shape and bone tissue formation. A case study showed that modifying pore architecture from regular to irregular enabled between 17 and 33% more bone formation within the 4-16-week time periods analyzed. This work shows that shape, specifically pore architecture, is as important as other design parameters such as material and manufacturing for improving the function of bone tissue scaffold implants. It is recommended that future research be conducted to both optimize irregular pore architectures and to explore the potential extension of the concept of shape modification beyond mechanical stress to look at other factors present in the body.
Collapse
Affiliation(s)
- Adel Alshammari
- School of Engineering, University of Manchester, Oxford Road, Manchester M13 9PL, UK; (F.A.); (W.W.)
- Engineering College, University of Hail, Hail 55476, Saudi Arabia
| | - Fahad Alabdah
- School of Engineering, University of Manchester, Oxford Road, Manchester M13 9PL, UK; (F.A.); (W.W.)
- Engineering College, University of Hail, Hail 55476, Saudi Arabia
| | - Weiguang Wang
- School of Engineering, University of Manchester, Oxford Road, Manchester M13 9PL, UK; (F.A.); (W.W.)
| | - Glen Cooper
- School of Engineering, University of Manchester, Oxford Road, Manchester M13 9PL, UK; (F.A.); (W.W.)
| |
Collapse
|
16
|
Yue X, Zhao L, Yang J, Jiao X, Wu F, Zhang Y, Li Y, Qiu J, Ke X, Sun X, Yang X, Gou Z, Zhang L, Yang G. Comparison of osteogenic capability of 3D-printed bioceramic scaffolds and granules with different porosities for clinical translation. Front Bioeng Biotechnol 2023; 11:1260639. [PMID: 37840661 PMCID: PMC10569306 DOI: 10.3389/fbioe.2023.1260639] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 09/08/2023] [Indexed: 10/17/2023] Open
Abstract
Pore parameters, structural stability, and filler morphology of artificial implants are key factors influencing the process of bone tissue repair. However, the extent to which each of these factors contributes to bone formation in the preparation of porous bioceramics is currently unclear, with the two often being coupled. Herein, we prepared magnesium-doped wollastonite (Mg-CSi) scaffolds with 57% and 70% porosity (57-S and 70-S) via a 3D printing technique. Meanwhile, the bioceramic granules (57-G and 70-G) with curved pore topography (IWP) were prepared by physically disrupting the 57-S and 70-S scaffolds, respectively, and compared for in vivo osteogenesis at 4, 10, and 16 weeks. The pore parameters and the mechanical and biodegradable properties of different porous bioceramics were characterized systematically. The four groups of porous scaffolds and granules were then implanted into a rabbit femoral defect model to evaluate the osteogenic behavior in vivo. 2D/3D reconstruction and histological analysis showed that significant bone tissue production was visible in the central zone of porous granule groups at the early stage but bone tissue ingrowth was slower in the porous scaffold groups. The bone tissue regeneration and reconstruction capacity were stronger after 10 weeks, and the porous architecture of the 57-S scaffold was maintained stably at 16 weeks. These experimental results demonstrated that the structure-collapsed porous bioceramic is favorable for early-stage osteoconduction and that the 3D topological scaffolds may provide more structural stability for bone tissue growth for a long-term stage. These findings provide new ideas for the selection of different types of porous bioceramics for clinical bone repair.
Collapse
Affiliation(s)
- Xusong Yue
- Department of Orthopaedics, Rui’an People’s Hospital, The Third Hospital Affiliated to Wenzhou Medical University, Wenzhou, China
| | - Liben Zhao
- Department of Orthopaedics, Rui’an People’s Hospital, The Third Hospital Affiliated to Wenzhou Medical University, Wenzhou, China
| | - Jun Yang
- Department of Orthopaedics, Rui’an People’s Hospital, The Third Hospital Affiliated to Wenzhou Medical University, Wenzhou, China
| | - Xiaoyi Jiao
- Department of Orthopaedics, Rui’an People’s Hospital, The Third Hospital Affiliated to Wenzhou Medical University, Wenzhou, China
| | - Fanghui Wu
- Department of Orthopaedics, Rui’an People’s Hospital, The Third Hospital Affiliated to Wenzhou Medical University, Wenzhou, China
| | - Yan Zhang
- Bio-Nanomaterials and Regenerative Medicine Research Division, Zhejiang-California International Nanosystem Institute, Zhejiang University, Hangzhou, China
| | - Yifan Li
- Department of Orthopaedics, The First Affiliated Hospital, School of Medicine of Zhejiang University, Hangzhou, China
| | - Jiandi Qiu
- Department of Orthopaedics, Rui’an People’s Hospital, The Third Hospital Affiliated to Wenzhou Medical University, Wenzhou, China
| | - Xiurong Ke
- Department of Orthopaedics, Rui’an People’s Hospital, The Third Hospital Affiliated to Wenzhou Medical University, Wenzhou, China
| | - Xiaoliang Sun
- Department of Orthopaedics, Rui’an People’s Hospital, The Third Hospital Affiliated to Wenzhou Medical University, Wenzhou, China
| | - Xianyan Yang
- Bio-Nanomaterials and Regenerative Medicine Research Division, Zhejiang-California International Nanosystem Institute, Zhejiang University, Hangzhou, China
| | - Zhongru Gou
- Bio-Nanomaterials and Regenerative Medicine Research Division, Zhejiang-California International Nanosystem Institute, Zhejiang University, Hangzhou, China
| | - Lei Zhang
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Guojing Yang
- Department of Orthopaedics, Rui’an People’s Hospital, The Third Hospital Affiliated to Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
17
|
Phuoc HD, Hoang PN, Yang S, Fraser D, Nguyen VT. Osseointegrability of 3D-printed porous titanium alloy implant on tibial shaft bone defect in rabbit model. PLoS One 2023; 18:e0282457. [PMID: 37682822 PMCID: PMC10490944 DOI: 10.1371/journal.pone.0282457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 02/11/2023] [Indexed: 09/10/2023] Open
Abstract
Previous studies have demonstrated the ability of osseointegration of porous titanium implants in cancellous bone. Our study was designed to (i) investigate the ability of bone ingrowth into 3D-printed porous titanium alloy implant on the cortical bone of rabbits using CT-scan and histology, and (ii) to identify the consistency of the radiology information between clinical Cone Beam Computed Tomography (CBCT) and Micro Computed Tomography (μCT) in the evaluation of bone ingrowth. The porous titanium alloy implants were 3D-printed employing the Electron Beam Melting (EBM) technology with an intended pore size of 600 μm and porosity of approximately 50 percent. Each implant was inserted into tibial diaphysis in one rabbit and its pores were classified as contacting bone or non-contacting bone. Depending on the time of explantation, the rabbits were divided into two groups: group 1 consisting of 6 rabbits between 13 and 20 weeks and group 2 consisting of 6 rabbits between 26 and 32 weeks. Tissue ingrowth into the non-bone contacting pores were evaluated by CBCT and histology. μCT was used to further investigate the bone ingrowth into four implants (two from each group were randomly chosen). The CBCT detected the present of tissue with bone-like density in both bone-contacting pores and non-bone-contacting pores of all implants. The μCT analysis also supported this result. All the bone-like tissues were then histologically confirmed to be mature bone. The analysis of CBCT data to assess bone ingrowth in porous implants had the sensitivity, specificity, positive and negative predictive values of 85, 84, 93 and 70 percent, respectively, when considering μCT assessment as the gold standard. Fully porous titanium alloy implant has great potential to reconstruct diaphyseal bone defect due to its good ability of osseointegration. CBCT is a promising method for evaluation of bone ingrowth into porous implants.
Collapse
Affiliation(s)
- Hung Do Phuoc
- Department of Orthopaedics and Rehabilitation, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
- Department of Orthopaedics and Traumatology, Cho Ray Hospital, Ho Chi Minh City, Vietnam
| | - Phu Nguyen Hoang
- Department of Orthopaedics and Rehabilitation, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
- Department of Orthopaedics and Traumatology, Cho Ray Hospital, Ho Chi Minh City, Vietnam
| | - Sam Yang
- Manufacturing, Commonwealth Scientific and Industrial Research Organisation, Clayton, Victoria, Australia
| | - Darren Fraser
- Manufacturing, Commonwealth Scientific and Industrial Research Organisation, Clayton, Victoria, Australia
| | - Vu Thua Nguyen
- Manufacturing, Commonwealth Scientific and Industrial Research Organisation, Clayton, Victoria, Australia
| |
Collapse
|
18
|
Bandyopadhyay A, Mitra I, Avila JD, Upadhyayula M, Bose S. Porous metal implants: processing, properties, and challenges. INTERNATIONAL JOURNAL OF EXTREME MANUFACTURING 2023; 5:032014. [PMID: 37476350 PMCID: PMC10355163 DOI: 10.1088/2631-7990/acdd35] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/26/2023] [Accepted: 06/09/2023] [Indexed: 07/22/2023]
Abstract
Porous and functionally graded materials have seen extensive applications in modern biomedical devices-allowing for improved site-specific performance; their appreciable mechanical, corrosive, and biocompatible properties are highly sought after for lightweight and high-strength load-bearing orthopedic and dental implants. Examples of such porous materials are metals, ceramics, and polymers. Although, easy to manufacture and lightweight, porous polymers do not inherently exhibit the required mechanical strength for hard tissue repair or replacement. Alternatively, porous ceramics are brittle and do not possess the required fatigue resistance. On the other hand, porous biocompatible metals have shown tailorable strength, fatigue resistance, and toughness. Thereby, a significant interest in investigating the manufacturing challenges of porous metals has taken place in recent years. Past research has shown that once the advantages of porous metallic structures in the orthopedic implant industry have been realized, their biological and biomechanical compatibility-with the host bone-has been followed up with extensive methodical research. Various manufacturing methods for porous or functionally graded metals are discussed and compared in this review, specifically, how the manufacturing process influences microstructure, graded composition, porosity, biocompatibility, and mechanical properties. Most of the studies discussed in this review are related to porous structures for bone implant applications; however, the understanding of these investigations may also be extended to other devices beyond the biomedical field.
Collapse
Affiliation(s)
- Amit Bandyopadhyay
- W. M. Keck Biomedical Materials Research Lab, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, United States of America
| | - Indranath Mitra
- W. M. Keck Biomedical Materials Research Lab, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, United States of America
| | - Jose D Avila
- W. M. Keck Biomedical Materials Research Lab, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, United States of America
| | - Mahadev Upadhyayula
- W. M. Keck Biomedical Materials Research Lab, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, United States of America
| | - Susmita Bose
- W. M. Keck Biomedical Materials Research Lab, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, United States of America
| |
Collapse
|
19
|
Driver CJ, Lopez V, Walton B, Jones D, Fentem R, Tomlinson A, Rose J. Instrumented cervical fusion using patient specific end-plate conforming interbody devices with a micro-porous structure in nine dogs with disk-associated cervical spondylomyelopathy. Front Vet Sci 2023; 10:1208593. [PMID: 37434865 PMCID: PMC10331472 DOI: 10.3389/fvets.2023.1208593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Accepted: 06/05/2023] [Indexed: 07/13/2023] Open
Abstract
Objective To report the medium and long-term outcome of nine dogs with disk-associated cervical spondylomyelopathy (DA-CSM), treated by instrumented interbody fusion using patient specific end-plate conforming device that features a micro-porous structure to facilitate bone in-growth. Study design A retrospective clinical study. Animals Nine medium and large breed dogs. Methods Medical records at two institutions were reviewed between January 2020 and 2023. Following magnetic resonance imaging (MRI) diagnosis of DA-CSM, pre-operative computed tomography (CT) scans were exported to computer software for in-silico surgical planning. Interbody devices were 3D-manufactured by selecting laser melting in titanium alloy. These were surgically implanted at 13 segments alongside mono-or bi-cortical vertebral stabilization systems. Follow-up included neurologic scoring and CT scans post-operative, at medium-term follow up and at long-term follow-up where possible. Interbody fusion and implant subsidence were evaluated from follow-up CT scans. Results Nine dogs were diagnosed with DA-CSM between C5-C7 at a total of 13 operated segments. Medium-term follow up was obtained between 2 and 8 months post-operative (3.00 ± 1.82 months). Neurologic scoring improved (p = 0.009) in eight of nine dogs. Distraction was significant (p < 0.001) at all segments. Fusion was evident at 12/13 segments. Subsidence was evident at 3/13 operated segments but was only considered clinically relevant in one dog that did not improve; as clinical signs were mild, revision surgery was not recommended. Long-term follow up was obtained between 9 and 33 months (14.23 ± 8.24 months); improvement was sustained in 8 dogs. The dog that suffered worsened thoracic limb paresis at medium-term follow up was also diagnosed with immune-mediated polyarthropathy (IMPA) and was euthanased 9 months post-operative due to unacceptable side-effects of corticosteroid therapy. Conclusion End-plate conforming interbody devices with a micro-porous structure were designed, manufactured, and successfully implanted in dog with DA-CSM. This resulted in CT-determined fusion with minimal subsidence in the majority of operated segments. Clinical significance The technique described can be used to distract and fuse cervical vertebrae in dogs with DA-CSM, with favorable medium-and long-term outcomes.
Collapse
Affiliation(s)
- Colin J. Driver
- Lumbry Park Veterinary Specialists, CVS Referrals, Alton, United Kingdom
| | - Victor Lopez
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
- Fusion Implants, Liverpool, United Kingdom
| | - Ben Walton
- Fusion Implants, Liverpool, United Kingdom
- Movement Referrals, Preston Brook, United Kingdom
| | - Dan Jones
- Fusion Implants, Liverpool, United Kingdom
| | - Rory Fentem
- Small Animal Teaching Hospital, University of Liverpool, Neston, United Kingdom
| | - Andrew Tomlinson
- Small Animal Teaching Hospital, University of Liverpool, Neston, United Kingdom
| | - Jeremy Rose
- Lumbry Park Veterinary Specialists, CVS Referrals, Alton, United Kingdom
| |
Collapse
|
20
|
Titanium Lattice Structures Produced via Additive Manufacturing for a Bone Scaffold: A Review. J Funct Biomater 2023; 14:jfb14030125. [PMID: 36976049 PMCID: PMC10059040 DOI: 10.3390/jfb14030125] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 02/08/2023] [Accepted: 02/23/2023] [Indexed: 03/03/2023] Open
Abstract
The progress in additive manufacturing has remarkably increased the application of lattice materials in the biomedical field for the fabrication of scaffolds used as bone substitutes. Ti6Al4V alloy is widely adopted for bone implant application as it combines both biological and mechanical properties. Recent breakthroughs in biomaterials and tissue engineering have allowed the regeneration of massive bone defects, which require external intervention to be bridged. However, the repair of such critical bone defects remains a challenge. The present review collected the most significant findings in the literature of the last ten years on Ti6Al4V porous scaffolds to provide a comprehensive summary of the mechanical and morphological requirements for the osteointegration process. Particular attention was given on the effects of pore size, surface roughness and the elastic modulus on bone scaffold performances. The application of the Gibson–Ashby model allowed for a comparison of the mechanical performance of the lattice materials with that of human bone. This allows for an evaluation of the suitability of different lattice materials for biomedical applications.
Collapse
|
21
|
The Effect of Tortuosity on Permeability of Porous Scaffold. Biomedicines 2023; 11:biomedicines11020427. [PMID: 36830961 PMCID: PMC9953537 DOI: 10.3390/biomedicines11020427] [Citation(s) in RCA: 55] [Impact Index Per Article: 27.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 01/25/2023] [Accepted: 01/26/2023] [Indexed: 02/05/2023] Open
Abstract
In designing porous scaffolds, permeability is essential to consider as a function of cell migration and bone tissue regeneration. Good permeability has been achieved by mimicking the complexity of natural cancellous bone. In this study, a porous scaffold was developed according to the morphological indices of cancellous bone (porosity, specific surface area, thickness, and tortuosity). The computational fluid dynamics method analyzes the fluid flow through the scaffold. The permeability values of natural cancellous bone and three types of scaffolds (cubic, octahedron pillar, and Schoen's gyroid) were compared. The results showed that the permeability of the Negative Schwarz Primitive (NSP) scaffold model was similar to that of natural cancellous bone, which was in the range of 2.0 × 10-11 m2 to 4.0 × 10-10 m2. In addition, it was observed that the tortuosity parameter significantly affected the scaffold's permeability and shear stress values. The tortuosity value of the NSP scaffold was in the range of 1.5-2.8. Therefore, tortuosity can be manipulated by changing the curvature of the surface scaffold radius to obtain a superior bone tissue engineering construction supporting cell migration and tissue regeneration. This parameter should be considered when making new scaffolds, such as our NSP. Such efforts will produce a scaffold architecturally and functionally close to the natural cancellous bone, as demonstrated in this study.
Collapse
|
22
|
Shum JM, Gadomski BC, Tredinnick SJ, Fok W, Fernandez J, Nelson B, Palmer RH, McGilvray KC, Hooper GJ, Puttlitz C, Easley J, Woodfield TBF. Enhanced bone formation in locally-optimised, low-stiffness additive manufactured titanium implants: An in silico and in vivo tibial advancement study. Acta Biomater 2023; 156:202-213. [PMID: 35413478 DOI: 10.1016/j.actbio.2022.04.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 04/05/2022] [Accepted: 04/05/2022] [Indexed: 01/18/2023]
Abstract
A tibial tuberosity advancement (TTA), used to treat lameness in the canine stifle, provides a framework to investigate implant performance within an uneven loading environment due to the dominating patellar tendon. The purpose of this study was to reassess how we design orthopaedic implants in a load-bearing model to investigate potential for improved osseointegration capacity of fully-scaffolded mechanically-matched additive manufactured (AM) implants. While the mechanobiological nature of bone is well known, we have identified a lower limit in the literature where investigation into exceedingly soft scaffolds relative to trabecular bone ceases due to the trade-off in mechanical strength. We developed a finite element model of the sheep stifle to assess the stresses and strains of homogeneous and locally-optimised TTA implant designs. Using additive manufacturing, we printed three different low-stiffness Ti-6Al-4 V TTA implants: 0.8 GPa (Ti1), 0.6 GPa (Ti2) and an optimised design with a 0.3 GPa cortex and 0.1 GPa centre (Ti3), for implantation in a 12-week in vivo ovine pilot study. Static histomorphometry demonstrated uniform bone ingrowth in optimised low-modulus Ti3 samples compared to homogeneous designs (Ti1 and Ti2), and greater bone-implant contact. Mineralising surfaces were apparent in all implants, though mineral apposition rate was only consistent throughout Ti3. The greatest bone formation scores were seen in Ti3, followed by Ti2 and Ti1. Results from our study suggest lower stiffnesses and higher strain ranges improve early bone formation, and that by accounting for loading environments through rational design, implants can be optimised to improve uniform osseointegration. STATEMENT OF SIGNIFICANCE: The effect of different strain ranges on bone healing has been traditionally investigated and characterised through computational models, with much of the literature suggesting higher strain ranges being favourable. However, little has been done to incorporate strain-optimisation into porous orthopaedic implants due to the trade-off in mechanical strength required to induce these microenvironments. In this study, we used finite element analysis to optimise the design of additive manufactured (AM) titanium orthopaedic implants for different strain ranges, using a clinically-relevant surgical model. Our research suggests that there is potential for locally-optimised AM scaffolds in the use of orthopaedic devices to induce higher strains, which in turn encourages de novo bone formation and uniform osseointegration.
Collapse
Affiliation(s)
- Josephine M Shum
- Christchurch Regenerative Medicine and Tissue Engineering (CReaTE) Group, Department of Orthopaedic Surgery & Musculoskeletal Medicine, Centre for Bioengineering & Nanomedicine, University of Otago, Christchurch, New Zealand
| | - Benjamin C Gadomski
- Orthopaedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, CO, United States
| | - Seamus J Tredinnick
- Christchurch Regenerative Medicine and Tissue Engineering (CReaTE) Group, Department of Orthopaedic Surgery & Musculoskeletal Medicine, Centre for Bioengineering & Nanomedicine, University of Otago, Christchurch, New Zealand
| | - Wilson Fok
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Justin Fernandez
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Bradley Nelson
- Orthopaedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, CO, United States
| | - Ross H Palmer
- Orthopaedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, CO, United States
| | - Kirk C McGilvray
- Orthopaedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, CO, United States
| | - Gary J Hooper
- Christchurch Regenerative Medicine and Tissue Engineering (CReaTE) Group, Department of Orthopaedic Surgery & Musculoskeletal Medicine, Centre for Bioengineering & Nanomedicine, University of Otago, Christchurch, New Zealand
| | - Christian Puttlitz
- Orthopaedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, CO, United States
| | - Jeremiah Easley
- Orthopaedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, CO, United States
| | - Tim B F Woodfield
- Christchurch Regenerative Medicine and Tissue Engineering (CReaTE) Group, Department of Orthopaedic Surgery & Musculoskeletal Medicine, Centre for Bioengineering & Nanomedicine, University of Otago, Christchurch, New Zealand.
| |
Collapse
|
23
|
Wang R, Ni S, Ma L, Li M. Porous construction and surface modification of titanium-based materials for osteogenesis: A review. Front Bioeng Biotechnol 2022; 10:973297. [PMID: 36091459 PMCID: PMC9452912 DOI: 10.3389/fbioe.2022.973297] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 07/29/2022] [Indexed: 11/13/2022] Open
Abstract
Titanium and titanium alloy implants are essential for bone tissue regeneration engineering. The current trend is toward the manufacture of implants from materials that mimic the structure, composition and elasticity of bones. Titanium and titanium alloy implants, the most common materials for implants, can be used as a bone conduction material but cannot promote osteogenesis. In clinical practice, there is a high demand for implant surfaces that stimulate bone formation and accelerate bone binding, thus shortening the implantation-to-loading time and enhancing implantation success. To avoid stress shielding, the elastic modulus of porous titanium and titanium alloy implants must match that of bone. Micro-arc oxidation technology has been utilized to increase the surface activity and build a somewhat hard coating on porous titanium and titanium alloy implants. More recently, a growing number of researchers have combined micro-arc oxidation with hydrothermal, ultrasonic, and laser treatments, coatings that inhibit bacterial growth, and acid etching with sand blasting methods to improve bonding to bone. This paper summarizes the reaction at the interface between bone and implant material, the porous design principle of scaffold material, MAO technology and the combination of MAO with other technologies in the field of porous titanium and titanium alloys to encourage their application in the development of medical implants.
Collapse
Affiliation(s)
- Rui Wang
- Department of Stomatology, The Second Hospital of Jilin University, Changchun, China
| | - Shilei Ni
- Department of Plastic and Aesthetic Surgery, Hospital of Stomatology, Jilin University, Changchun, China
| | - Li Ma
- Department of Fever Clinic, The Second Hospital of Jilin University, Changchun, China
| | - Meihua Li
- Department of Stomatology, The Second Hospital of Jilin University, Changchun, China
- *Correspondence: Meihua Li,
| |
Collapse
|
24
|
Giugovaz A, Pérez-Giugovaz MG, Al-Haj Husain N, Barmak AB, Özcan M, Revilla-León M. Flexural strength of aged and nonaged interim materials fabricated by using milling, additive manufacturing, and a combination of subtractive and additive methods. J Prosthet Dent 2022; 128:513.e1-513.e11. [DOI: 10.1016/j.prosdent.2022.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 05/16/2022] [Accepted: 05/18/2022] [Indexed: 10/16/2022]
|
25
|
Fu J, Ni M, Zhu F, Li X, Chai W, Hao L, Zhou Y, Zhang G, Chen J. Reconstruction of Paprosky Type
III
Acetabular Defects by Three‐Dimensional Printed Porous Augment: Techniques and Clinical Outcomes of 18 Consecutive Cases. Orthop Surg 2022; 14:1004-1010. [PMID: 35377531 PMCID: PMC9087386 DOI: 10.1111/os.13250] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 02/06/2022] [Accepted: 02/18/2022] [Indexed: 11/30/2022] Open
Abstract
Objective To introduce the surgical technique of reconstruction of Paprosky type III acetabular defects by 3D printed porous augments. Methods First, CT scans of pelvis were obtained to establish the 3D reconstruction model of 3D printed porous augment. Then, a nylon pelvis model was printed to simulate operation with the surgeons. At this time, the augment was designed and modified according to the surgeon's suggestions and the 3D printing principles. Eighteen patients with Paprosky type III acetabular defects receiving reconstructive surgery by 3D printed porous augments were included in current study. Their data, including general information, intra‐operative findings, imaging results, functional scores, and complications were retrospectively analyzed. Results The mean follow‐up time lasted 33.3 ± 2.0 (24–56) months. The average limb‐length discrepancy (LLD) was 31.7 ± 4.2 (3–59) mm preoperatively, 7.7 ± 1.4 (1–21) mm postoperatively (P < 0.0001), and 7.5 ± 1.2 (0–18) mm at the latest follow‐up. The mean vertical position of hip center of rotation (HCOR) from the interteardrop line changed from preoperative 50.7 ± 3.9 (23.3–75.3) mm to postoperative 22.9 ± 1.9 (10.1–40.3) mm (P < 0.0001), with the latest follow‐up revealing an HCOR of 22.3 ± 1.7 (11.0–40.5) mm. Follow‐up study showed that no hip had radiolucencies and radiological loosening of the acetabular components and augment. The average Harris hip score (HHS) improved from 40.3 ± 4.5 (10.5–71) before operation to 88.4 ± 1.9 (75–97) at the last follow‐up (P < 0.0001). Moreover, follow‐up exhibited that no periprosthetic joint infection, hip dislocation, fracture, and re‐revision occurred. Conclusion Surgical treatment of Paprosky type III acetabular defect with 3D printed porous augment was simple, achieved good match between porous augment and the defect bone surface and the acetabular component, ideally restored LLD and HCOR after operation, significantly improved HHS and attained good early clinical outcomes. It is a promising personalized solution for patients with severe acetabular bone defect.
Collapse
Affiliation(s)
- Jun Fu
- Senior Department of Orthopaedics The Forth Medical Centre of Chinese PLA General Hospital Beijing China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation Beijing China
- Department of Orthopaedics The First Medical Centre of Chinese PLA General Hospital Beijing China
| | - Ming Ni
- Senior Department of Orthopaedics The Forth Medical Centre of Chinese PLA General Hospital Beijing China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation Beijing China
- Department of Orthopaedics The First Medical Centre of Chinese PLA General Hospital Beijing China
| | - Fangzheng Zhu
- Department of Orthopaedics PLA Rocket Force Characteristic Medical Center Beijing China
| | - Xiang Li
- Senior Department of Orthopaedics The Forth Medical Centre of Chinese PLA General Hospital Beijing China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation Beijing China
- Department of Orthopaedics The First Medical Centre of Chinese PLA General Hospital Beijing China
| | - Wei Chai
- Senior Department of Orthopaedics The Forth Medical Centre of Chinese PLA General Hospital Beijing China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation Beijing China
- Department of Orthopaedics The First Medical Centre of Chinese PLA General Hospital Beijing China
| | - Libo Hao
- Senior Department of Orthopaedics The Forth Medical Centre of Chinese PLA General Hospital Beijing China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation Beijing China
- Department of Orthopaedics The First Medical Centre of Chinese PLA General Hospital Beijing China
| | - Yonggang Zhou
- Senior Department of Orthopaedics The Forth Medical Centre of Chinese PLA General Hospital Beijing China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation Beijing China
- Department of Orthopaedics The First Medical Centre of Chinese PLA General Hospital Beijing China
| | - Guoqiang Zhang
- Senior Department of Orthopaedics The Forth Medical Centre of Chinese PLA General Hospital Beijing China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation Beijing China
- Department of Orthopaedics The First Medical Centre of Chinese PLA General Hospital Beijing China
| | - Jiying Chen
- Senior Department of Orthopaedics The Forth Medical Centre of Chinese PLA General Hospital Beijing China
- National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation Beijing China
- Department of Orthopaedics The First Medical Centre of Chinese PLA General Hospital Beijing China
| |
Collapse
|
26
|
Munford MJ, Xiao D, Jeffers JRT. Lattice implants that generate homeostatic and remodeling strains in bone. J Orthop Res 2022; 40:871-877. [PMID: 34086355 DOI: 10.1002/jor.25114] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 04/16/2021] [Accepted: 05/31/2021] [Indexed: 02/04/2023]
Abstract
Bone remodeling is mediated by several factors including strain. An increase in strain between 1% and 10% compared to homeostasis can trigger bone formation. We aim to create an orthopedic implant using clinically established imaging and manufacturing methods that induces this strain control in human bone. Titanium scaffolds were manufactured with multiaxial apparent modulus tailored to the mechanical properties of bone defined from computed tomography scans of cadaver human tibiae. Five bone cubes were tested with corresponding titanium scaffolds by loading under compression, which is similar to the implanted tibia loading condition. Bone strain was precisely controlled by varying the scaffold modulus, from 0% to 15% bone strain increase. This strain increase is the magnitude reported to invoke bone's positive remodeling. Axial modulus was closely matched between titanium scaffolds and bone, ranging from 48-728 and 81-800 MPa, respectively, whereby scaffold axial modulus was within 2% of nominal target values. Fine control of multiaxial moduli resulted in transverse modulus that matched bone well; ranging from 42-648 and 47-585 MPa in scaffolds and bone respectively. The scaffold manufacturing material and method are already used in the orthopedic industry. This study has significant clinical implications as it enables the design of implants which positively harness bone's natural mechanoresponse and respect bone's mechanical anisotropy and heterogeneity.
Collapse
Affiliation(s)
- Maxwell J Munford
- Department of Mechanical Engineering, Imperial College London, South Kensington, London, UK
| | - Dannier Xiao
- Department of Mechanical Engineering, Imperial College London, South Kensington, London, UK
| | - Jonathan R T Jeffers
- Department of Mechanical Engineering, Imperial College London, South Kensington, London, UK
| |
Collapse
|
27
|
3D-printed, bi-layer, biomimetic artificial periosteum for boosting bone regeneration. Biodes Manuf 2022. [DOI: 10.1007/s42242-022-00191-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
28
|
Munford MJ, Stoddart JC, Liddle AD, Cobb JP, Jeffers JRT. Total and partial knee arthroplasty implants that maintain native load transfer in the tibia. Bone Joint Res 2022; 11:91-101. [PMID: 35168367 PMCID: PMC8882327 DOI: 10.1302/2046-3758.112.bjr-2021-0304.r1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
AIMS Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but the solid metal implants disrupt the natural distribution of stress and strain which can lead to bone loss over time. This generates problems if the implant needs to be revised. This study investigates whether titanium lattice UKA and TKA implants can maintain natural load transfer in the proximal tibia. METHODS In a cadaveric model, UKA and TKA procedures were performed on eight fresh-frozen knee specimens, using conventional (solid) and titanium lattice tibial implants. Stress at the bone-implant interfaces were measured and compared to the native knee. RESULTS Titanium lattice implants were able to restore the mechanical environment of the native tibia for both UKA and TKA designs. Maximum stress at the bone-implant interface ranged from 1.2 MPa to 3.3 MPa compared with 1.3 MPa to 2.7 MPa for the native tibia. The conventional solid UKA and TKA implants reduced the maximum stress in the bone by a factor of 10 and caused > 70% of bone surface area to be underloaded compared to the native tibia. CONCLUSION Titanium lattice implants maintained the natural mechanical loading in the proximal tibia after UKA and TKA, but conventional solid implants did not. This is an exciting first step towards implants that maintain bone health, but such implants also have to meet fatigue and micromotion criteria to be clinically viable. Cite this article: Bone Joint Res 2022;11(2):91-101.
Collapse
Affiliation(s)
- Maxwell J. Munford
- The Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, UK
| | - Jennifer C. Stoddart
- The Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, UK
| | - Alexander D. Liddle
- The MSk Lab, Department of Surgery and Cancer, Imperial College London, London, UK
| | - Justin P. Cobb
- The MSk Lab, Department of Surgery and Cancer, Imperial College London, London, UK
| | - Jonathan R. T. Jeffers
- The Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, UK
| |
Collapse
|
29
|
Zhang Y, Sun N, Zhu M, Qiu Q, Zhao P, Zheng C, Bai Q, Zeng Q, Lu T. The contribution of pore size and porosity of 3D printed porous titanium scaffolds to osteogenesis. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2022; 133:112651. [PMID: 35034817 DOI: 10.1016/j.msec.2022.112651] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 12/16/2021] [Accepted: 01/04/2022] [Indexed: 12/18/2022]
Abstract
Porous titanium implants were popularly fabricated to promote bone formation. A desirable porous scaffold was recommended to be with porosity of >60% or/and pore size of >300 μm for better osteointegration. However, whether the pore size and porosity could be randomly selected within the recommended values? And what is the correlation between pore size and porosity for accelerating osteointegration? In this study, porous titanium with cubic cell structure was produced by selective laser melting. The designed porosities of scaffolds with 700-μm pore size were 40%, 70% and 90%; and the pore sizes of scaffolds with 70% porosity were 400, 700 and 900 μm. The in vitro osteogenic potential and in vivo bone formation were investigated. Results showed that porosity and pore size could be tuned by altering strut size, which was further directly responsible for mechanical properties. Besides, pore size and porosity synergistically contributed to osteogenic activity in vitro and new bone formation in vivo. In regard to pore sizes herein, the optimized one for better osteogenic response and bone forming ability was ~600-700 μm (p70). Too smaller or too larger pore size might more or less hinder cellular behaviors and bone regeneration, even if both pore size (300-900 μm) and porosity (70%) were within the recommended value range. At a constant pore size (~600-700 μm), p70 and p90 with higher porosity was more conductive to biological effects, compared with p40. As a result, pore-size variation revealed more significant influence on osteogenesis, compared with variation of porosity within recommended values. However, the applicable porosity within recommended values should be designed with the consideration of specific load-bearing conditions. This study helps to provide guidance for designing porous scaffolds with appropriate mechanical strengths and effective bone-forming ability, so as to develop better custom-made bone substitutes.
Collapse
Affiliation(s)
- Yanni Zhang
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Na Sun
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Mengran Zhu
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Quanrun Qiu
- Research Centre for Nano Energy Materials, Queen Mary University of London Engineering School, Northwestern Polytechnical University, Xi'an 710072, China
| | - Pengju Zhao
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Caiyun Zheng
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Que Bai
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Qingyan Zeng
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Tingli Lu
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China.
| |
Collapse
|
30
|
Schmidt M, Waselau AC, Feichtner F, Julmi S, Klose C, Maier HJ, Wriggers P, Meyer-Lindenberg A. In vivo investigation of open-pored magnesium scaffolds LAE442 with different coatings in an open wedge defect. J Appl Biomater Funct Mater 2022; 20:22808000221142679. [PMID: 36545893 DOI: 10.1177/22808000221142679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
The magnesium alloy LAE442 showed promising results as a bone substitute in numerous studies in non-weight bearing bone defects. This study aimed to investigate the in vivo behavior of wedge-shaped open-pored LAE442 scaffolds modified with two different coatings (magnesium fluoride (MgF2, group 1)) or magnesium fluoride/calcium phosphate (MgF2/CaP, group 2)) in a partial weight-bearing rabbit tibia defect model. The implantation of the scaffolds was performed as an open wedge corrective osteotomy in the tibia of 40 rabbits and followed for observation periods of 6, 12, 24, and 36 weeks. Radiological and microcomputed tomographic examinations were performed in vivo. X-ray microscopic, histological, histomorphometric, and SEM/EDS analyses were performed at the end of each time period. µCT measurements and X-ray microscopy showed a slight decrease in volume and density of the scaffolds of both coatings. Histologically, endosteal and periosteal callus formation with good bridging and stabilization of the osteotomy gap and ingrowth of bone into the scaffold was seen. The MgF2 coating favored better bridging of the osteotomy gap and more bone-scaffold contacts, especially at later examination time points. Overall, the scaffolds of both coatings met the requirement to withstand the loads after an open wedge corrective osteotomy of the proximal rabbit tibia. However, in addition to the inhomogeneous degradation behavior of individual scaffolds, an accumulation of gas appeared, so the scaffold material should be revised again regarding size dimension and composition.
Collapse
Affiliation(s)
- Marlene Schmidt
- Clinic of Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Anja-Christina Waselau
- Clinic of Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Franziska Feichtner
- Clinic of Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Stefan Julmi
- Institut für Werkstoffkunde (Materials Science), Leibniz Universität Hannover, Garbsen, Germany
| | - Christian Klose
- Institut für Werkstoffkunde (Materials Science), Leibniz Universität Hannover, Garbsen, Germany
| | - Hans Jürgen Maier
- Institut für Werkstoffkunde (Materials Science), Leibniz Universität Hannover, Garbsen, Germany
| | - Peter Wriggers
- Institute of Continuum Mechanics, Leibniz Universität Hannover, Garbsen, Germany
| | - Andrea Meyer-Lindenberg
- Clinic of Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Munich, Germany
| |
Collapse
|
31
|
McGregor M, Patel S, McLachlin S, Vlasea M. Data related to architectural bone parameters and the relationship to Ti lattice design for powder bed fusion additive manufacturing. Data Brief 2021; 39:107633. [PMID: 34917699 PMCID: PMC8646123 DOI: 10.1016/j.dib.2021.107633] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/18/2021] [Accepted: 11/22/2021] [Indexed: 11/25/2022] Open
Abstract
The data included in this article provides additional supporting information on our publication (McGregor et al. [1]) on the review of the natural lattice architecture in human bone and its implication towards titanium (Ti) lattice design for laser powder bed fusion and electron beam powder bed fusion. For this work, X-ray computed tomography was deployed to understand and visualize a Ti-6Al-4V lattice structure manufactured by laser powder bed fusion. This manuscript includes details about the manufacturing of the lattice structure using laser powder bed fusion and computed tomography methods used for analyzing the lattice structure. Additionally, a comprehensive literature review was conducted to understand how lattice parameters are controlled in additively manufactured Ti and Ti-alloy parts aimed at replacing or augmenting human bone. From this literature review, lattice design information was collected and is summarized in tabular form in this manuscript.
Collapse
Affiliation(s)
- Martine McGregor
- University of Waterloo, Department of Mechanical and Mechatronics Engineering, Waterloo, ON N2L 3G1, Canada
| | - Sagar Patel
- University of Waterloo, Department of Mechanical and Mechatronics Engineering, Waterloo, ON N2L 3G1, Canada
| | - Stewart McLachlin
- University of Waterloo, Department of Mechanical and Mechatronics Engineering, Waterloo, ON N2L 3G1, Canada
| | - Mihaela Vlasea
- University of Waterloo, Department of Mechanical and Mechatronics Engineering, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
32
|
Ferguson BM, Entezari A, Fang J, Li Q. Optimal placement of fixation system for scaffold-based mandibular reconstruction. J Mech Behav Biomed Mater 2021; 126:104855. [PMID: 34872868 DOI: 10.1016/j.jmbbm.2021.104855] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 09/19/2021] [Accepted: 09/21/2021] [Indexed: 12/23/2022]
Abstract
A current challenge in bone tissue engineering is to create favourable biomechanical conditions conducive to tissue regeneration for a scaffold implanted in a segmental defect. This is particularly the case immediately following surgical implantation when a firm mechanical union between the scaffold and host bone is yet to be established via osseointegration. For mandibular reconstruction of a large segmental defect, the position of the fixation system is shown here to have a profound effect on the mechanical stimulus (for tissue regeneration within the scaffold), structural strength, and structural stiffness of the tissue scaffold-host bone construct under physiological load. This research combines computer tomography (CT)-based finite element (FE) modelling with multiobjective optimisation to determine the optimal height and angle to place a titanium fixation plate on a reconstructed mandible so as to enhance tissue ingrowth, structural strength and structural stiffness of the scaffold-host bone construct. To this end, the respective design criteria for fixation plate placement are to: (i) maximise the volume of the tissue scaffold experiencing levels of mechanical stimulus sufficient to initiate bone apposition, (ii) minimise peak stress in the scaffold so that it remains intact with a diminished risk of failure and, (iii) minimise scaffold ridge displacement so that the reconstructed jawbone resists deformation under physiological load. First, a CT-based FE model of a reconstructed human mandible implanted with a bioceramic tissue scaffold is developed to visualise and quantify changes in the biomechanical responses as the fixation plate's height and/or angle are varied. The volume of the scaffold experiencing appositional mechanical stimulus is observed to increase with the height of the fixation plate. Also, as the principal load-transfer mechanism to the scaffold is via the fixation system, there is a significant ingress of appositional stimulus from the buccal side towards the centre of the scaffold, notably in the region bounded by the screws. Next, surrogate modelling is implemented to generate bivariate cubic polynomial functions of the three biomechanical responses with respect to the two design variables (height and angle). Finally, as the three design objectives are found to be competing, bi- and tri-objective particle swarm optimisation algorithms are invoked to determine the most optimal Pareto solution, which represents the best possible trade-off between the competing design objectives. It is recommended that consideration be given to placing the fixation system along the upper boundary of the mandible with a small clockwise rotation about its posterior end. The methodology developed here forms a useful decision aid for optimal surgical planning.
Collapse
Affiliation(s)
- Ben M Ferguson
- School of Aerospace, Mechanical and Mechatronic Engineering, Faculty of Engineering and Australian Research Council Centre for Innovative BioEngineering, The University of Sydney, NSW, 2006, Australia.
| | - Ali Entezari
- School of Aerospace, Mechanical and Mechatronic Engineering, Faculty of Engineering and Australian Research Council Centre for Innovative BioEngineering, The University of Sydney, NSW, 2006, Australia
| | - Jianguang Fang
- School of Civil and Environmental Engineering, Faculty of Engineering and Information Technology, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| | - Qing Li
- School of Aerospace, Mechanical and Mechatronic Engineering, Faculty of Engineering and Australian Research Council Centre for Innovative BioEngineering, The University of Sydney, NSW, 2006, Australia
| |
Collapse
|
33
|
Meena VK, Kumar P, Kalra P, Sinha RK. Additive manufacturing for metallic spinal implants: A systematic review. ANNALS OF 3D PRINTED MEDICINE 2021. [DOI: 10.1016/j.stlm.2021.100021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
|
34
|
Li J, Cao F, Wu B, Yang J, Xu W, Wang W, Wei X, Liu G, Zhao D. Immobilization of bioactive vascular endothelial growth factor onto Ca-deficient hydroxyapatite-coated Mg by covalent bonding using polydopamine. J Orthop Translat 2021; 30:82-92. [PMID: 34660198 PMCID: PMC8487887 DOI: 10.1016/j.jot.2021.06.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 05/27/2021] [Accepted: 06/14/2021] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND Bone tissue engineering (BTE) is considered a promising technology for repairing bone defects. Mg2+ promotes osteogenesis, which makes Mg-based scaffolds popular for research on orthopedic implant materials. Angiogenesis plays an important role in the process of bone tissue repair and regeneration, and it is one of the important problems in BTE urgently needs to be solved. METHODS Mg was firstly coated with Ca-deficient hydroxyapatite (CDHA) via hydrothermal treatment, and polydopamine (DOPA) was then used as the connecting medium to immobilize vascular endothelial growth factor (VEGF) on the CDHA coating. The physicochemical properties of the coatings were characterized by SEM, EDS, XPS, FTIR and immersion experiment in SBF. The ahesion, proliferation, and angiogenesis potential of the coatings were determined in vitro. RESULTS The composite coating significantly improved the corrosion resistance of Mg and prohibited excessively high local alkalinity. VEGF could be firmly immobilized on Mg via polydopamine. The CCK-8, live/dead staining and adhesion test results showed that the VEGF-DOPA-CDHA coating exhibited excellent biocompatibility and could significantly improve the adhesion and proliferation of MC3T3-E1 cells on Mg. Microtubule formation, immunofluorescence and Quantitative Real-Time PCR (qRT-PCR) experiments showed that VEGF immobilized on Mg still possessed bioactivity in promoting the differentiation of rat mesenchymal stem cells into endothelial cells. CONCLUSION In this study, we enabled the angiogenic biological activity of Mg by immobilizing VEGF on Mg. Mg was successfully coated with a functional VEGF-DOPA-CDHA composite coating. The CDHA coating significantly increased the corrosion resistance of Mg and prohibited the negative effect of excessively high local alkalinity on the biological activity of VEGF. As an intermediate layer, the DOPA coating protects Mg, and DOPA provides a binding site for VEGF so that VEGF can be firmly immobilized on Mg and give Mg angiogenic bioactivity during the initial period of implantation. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE The treatment of large bone defect is still one of the orthopedic trauma diseases that are difficult to be completely treated in clinic. The development of tissue engineering technology provides a new option for the treatment of large bone defects. The regeneration of blood vessels is of great significance for the repair of bone defects. In this study, VEGF was connected on the surface of degradable magnesium by covalent bonding. Vascular biofunctionalized magnesium scaffolds are expected to regenerate bone tissue with blood transport and be used in the clinical treatment of large bone defects.
Collapse
Affiliation(s)
- Junlei Li
- Department of Orthopaedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, 116001, China
| | - Fang Cao
- Department of Biomedical Engineering, Faculty of Electronic Information and Electronical Engineering, Dalian University of Technology, Dalian, 116024, China
| | - Bin Wu
- Department of Orthopaedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, 116001, China
| | - Jiahui Yang
- Department of Orthopaedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, 116001, China
| | - Wenwu Xu
- Department of Orthopaedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, 116001, China
| | - Weidan Wang
- Department of Orthopaedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, 116001, China
| | - Xiaowei Wei
- Department of Orthopaedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, 116001, China
| | - Ge Liu
- Department of Orthopaedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, 116001, China
| | - Dewei Zhao
- Department of Orthopaedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, 116001, China
| |
Collapse
|
35
|
Revilla-León M, Zandinejad A. Two-layer additively manufactured crown: Proof of concept. J Dent 2021; 112:103730. [PMID: 34146654 DOI: 10.1016/j.jdent.2021.103730] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 05/26/2021] [Accepted: 06/08/2021] [Indexed: 10/21/2022] Open
Abstract
OBJECTIVES To assess the feasibility of additively manufacturing a crown with a 2-layer design. METHODS A mandibular first molar tooth preparation titanium die for a full coverage restoration was obtained. The die was used to design a monolayer (ML group) and 2-layer (2L group) anatomically contoured crown. In the ML group, the specimen was manufactured with a hard polymer (Rigur RGD450; Stratasys). In the 2L group, the crown was splinted into 2 parts: the intaglio that represented 25% of the total crown volume that was manufactured with a resilient polymer (Vero; Stratasys) and the exterior that represented the remaining crown volume that was manufactured with a hard polymer (Rigur RGD450; Stratasys). Specimens were manufactured using a material jetting printer (Connex3 Object260; Stratasys). The marginal and internal discrepancies of ML and 2L specimens were visually assessed. RESULTS The ML and 2L specimens were manufactured using a material jetting printer that obtained a visually acceptable marginal and internal discrepancy. CONCLUSIONS The 2-layer dental crown can be manufactured using a material jetting printer. CLINICAL SIGNIFICANCE Material jetting technology has the capability to fabricate a 2-layer dental crown design which can be fabricated using materials with different properties.
Collapse
Affiliation(s)
- Marta Revilla-León
- AEGD Residency, Comprehensive Dentistry Department, College of Dentistry, Texas A&M University, Dallas, TX, United States; Affiliate Faculty Graduate Prosthodontics, Restorative Dentistry Department, School of Dentistry, University of Washington, Seattle, WA, United States; Revilla Research Center, Madrid, Spain.
| | - Amirali Zandinejad
- AEGD Residency, Comprehensive Dentistry Department, College of Dentistry, Texas A&M University, Dallas, TX, United States
| |
Collapse
|
36
|
Osseointegration Improvement of Co-Cr-Mo Alloy Produced by Additive Manufacturing. Pharmaceutics 2021; 13:pharmaceutics13050724. [PMID: 34069254 PMCID: PMC8156199 DOI: 10.3390/pharmaceutics13050724] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 05/07/2021] [Accepted: 05/10/2021] [Indexed: 12/14/2022] Open
Abstract
Cobalt-base alloys (Co-Cr-Mo) are widely employed in dentistry and orthopedic implants due to their biocompatibility, high mechanical strength and wear resistance. The osseointegration of implants can be improved by surface modification techniques. However, complex geometries obtained by additive manufacturing (AM) limits the efficiency of mechanical-based surface modification techniques. Therefore, plasma immersion ion implantation (PIII) is the best alternative, creating nanotopography even in complex structures. In the present study, we report the osseointegration results in three conditions of the additively manufactured Co-Cr-Mo alloy: (i) as-built, (ii) after PIII, and (iii) coated with titanium (Ti) followed by PIII. The metallic samples were designed with a solid half and a porous half to observe the bone ingrowth in different surfaces. Our results revealed that all conditions presented cortical bone formation. The titanium-coated sample exhibited the best biomechanical results, which was attributed to the higher bone ingrowth percentage with almost all medullary canals filled with neoformed bone and the pores of the implant filled and surrounded by bone ingrowth. It was concluded that the metal alloys produced for AM are biocompatible and stimulate bone neoformation, especially when the Co-28Cr-6Mo alloy with a Ti-coated surface, nanostructured and anodized by PIII is used, whose technology has been shown to increase the osseointegration capacity of this implant.
Collapse
|
37
|
Peng WM, Cheng KJ, Liu YF, Nizza M, Baur DA, Jiang XF, Dong XT. Biomechanical and Mechanostat analysis of a titanium layered porous implant for mandibular reconstruction: The effect of the topology optimization design. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 124:112056. [PMID: 33947550 DOI: 10.1016/j.msec.2021.112056] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 03/12/2021] [Accepted: 03/20/2021] [Indexed: 11/18/2022]
Abstract
A porous scaffold/implant is considered a potential method to repair bone defects, but its mechanical stability and biomechanics during the repair process are not yet clear. A mandibular titanium implant was proposed and designed with layered porous structures similar to that of the bone tissue, both in structure and mechanical properties. Topology was used to optimize the design of the porous implant and fixed structure. The finite element analysis was combined with bone "Mechanostat" theory to evaluate the stress and osteogenic property of the layered porous implant with 3 different fixation layouts (Model I with 4 screws, Model II with 5 screws and Model III with 6 screws) for mandibular reconstruction. The results showed that Model III could effectively reduce the stress shielding effect, stress within the optimized implant, defective mandible, and screws were respectively dropped 48.18%, 44.23%, and 57.27% compared to Model I, and the porous implant had a significant stress transmission effect and maintained the same stress distribution as the intact mandible after the mandibular defect was repaired. The porous implant also showed a significant mechanical stimulation effect on the growth and healing of the bone tissue according to the bone "Mechanostat" theory. The combination of porous structure with the topology technique is a promising option to improve the mechanical stability and osteogenesis of the implant, and could provide a new solution for mandibular reconstruction.
Collapse
Affiliation(s)
- Wen-Ming Peng
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China; National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou 310023, China
| | - Kang-Jie Cheng
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China; National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou 310023, China
| | - Yun-Feng Liu
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China; National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou 310023, China.
| | - Mark Nizza
- Department of Oral and Maxillofacial Surgery, School of Dental Medicine, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Dale A Baur
- Department of Oral and Maxillofacial Surgery, School of Dental Medicine, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Xian-Feng Jiang
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China; National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou 310023, China
| | - Xing-Tao Dong
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China; National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou 310023, China
| |
Collapse
|
38
|
Current interpretations on the in vivo response of bone to additively manufactured metallic porous scaffolds: A review. BIOMATERIALS AND BIOSYSTEMS 2021; 2:100013. [PMID: 36824658 PMCID: PMC9934422 DOI: 10.1016/j.bbiosy.2021.100013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 01/20/2021] [Accepted: 02/13/2021] [Indexed: 01/08/2023] Open
Abstract
Recent advances in the field of metallic additive manufacturing have expanded production capabilities for bone implants to include porous lattice structures. While traditional models of de novo bone formation can be applied to fully dense implant materials, their applicability to the interior of porous materials has not been well-characterized. Unlike other reviews that focus on materials and mechanical properties of lattice structures, this review compiles biological performance from in vivo studies in pre-clinical models only. First, we introduce the most common lattice geometry designs employed in vivo and discuss some of their fabrication advantages and limitations. Then lattice geometry is correlated to quantitative (histomorphometric) and qualitative (histological) assessments of osseointegration. We group studies according to two common implant variables: pore size and percent porosity, and explore the extent of osseointegration using common measures, including bone-implant contact (BIC), bone area (BA), bone volume/total volume (BV/TV) and biomechanical stability, for various animal models and implantation times. Based on this, trends related to in vivo bone formation on the interior of lattice structures are presented. Common challenges with lattice structures are highlighted, including nonuniformity of bone growth through the entirety of the lattice structure due to occlusion effects and avascularity. This review paper identifies a lack of systematic in vivo studies on porous AM implants to target optimum geometric design, including pore shape, size, and percent porosity in controlled animal models and critical-sized defects. Further work focusing on surface modification strategies and systematic geometric studies to homogenize in vivo bone growth through the scaffold interior are recommended to increase implant stability in the early stages of osseointegration.
Collapse
|
39
|
Enhanced compressive strengths and induced cell growth of 1-3-type BaTiO 3/PMMA bio-piezoelectric composites. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 120:111699. [PMID: 33545858 DOI: 10.1016/j.msec.2020.111699] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 10/24/2020] [Accepted: 10/30/2020] [Indexed: 12/15/2022]
Abstract
Barium titanate (BaTiO3) has been used as a bone implant material because of its piezoelectric properties and the ability to promote cell growth when combined with hydroxyapatite. However, the brittleness of BaTiO3 inhibits its use as a bone replacement material at load-bearing sites, and the reduction of BaTiO3 content in the composite reduces its piezoelectric effect on bone growth. In this study, we explored a preparation method, which included directional freeze casting and self-solidification of bone cement, to obtain 1-3-type BaTiO3/PMMA bio-piezoelectric composites with a lamellar structure. The lamellar BaTiO3 layer through the composite from the bottom to the top significantly improved the piezoelectric properties of the composite. In addition, the dendritic ceramic bridges on the BaTiO3 pore walls can improve the compressive strength and elastic modulus of BaTiO3/PMMA bio-piezoelectric composites with a lamellar structure. More importantly, it was found that polarized lamellar BaTiO3 could induce osteoblasts to grow in the direction of the BaTiO3 layers. When the width of the BaTiO3 layer was in the range of 8-21 μm, osteoblasts along the BaTiO3 layer showed well growth, which can be of great value for the production of biomimetic bone units.
Collapse
|
40
|
Kelly CN, Lin AS, Leguineche KE, Shekhar S, Walsh WR, Guldberg RE, Gall K. Functional repair of critically sized femoral defects treated with bioinspired titanium gyroid-sheet scaffolds. J Mech Behav Biomed Mater 2021; 116:104380. [PMID: 33588248 DOI: 10.1016/j.jmbbm.2021.104380] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 01/05/2021] [Accepted: 01/30/2021] [Indexed: 01/19/2023]
Abstract
Despite the innate ability for bone to remodel and repair, its regeneration has a limit. In these cases of critically sized bone defects (CSBD), the bone deficit must be repaired using reconstructive techniques that support immediate load bearing and encourage bone bridging across the defect. High-strength porous titanium implants offer a solution for treatment of CSBD in which the scaffold can support physiological loads, provide a matrix to guide ingrowth, and carry graft materials and/or biologics. Fabrication of titanium meta-materials via additive manufacturing (AM) has unlocked the potential to modulate mechanical and biological performance to achieve a combination of properties previously unachievable. Meta-material scaffolds with topology based on triply periodic minimal surfaces (TPMS) have gained increasing interest for use in biomedical applications due to their bioinspired nature. Despite enthusiasm for TPMS-based titanium scaffolds due to their high strength to stiffness ratio, high permeability, and curvature similar to trabecular bone, there is little preclinical evidence to support their in vivo response in bone. The present study sought to evaluate the performance of gyroid-sheet titanium scaffolds produced via AM to repair a critically size femoral cortical bone defect in rats. Empty gyroid-sheet scaffolds were shown to repair segmental defects with up to 38% of torsional strength and 54% torsional stiffness of the intact femur (control) at 12-weeks. Gyroid-sheet scaffolds carrying recombinant bone morphogenic protein-2 demonstrated bridging bone growth across the length of the defect, with torsional strength and stiffness superior to that of the intact controls.
Collapse
Affiliation(s)
- Cambre N Kelly
- Department of Biomedical Engineering, Duke University, Durham, NC, USA; Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA
| | - Angela Sp Lin
- The Knight Campus for Accelerating Scientific Impact, University of Oregon, Eugene, OR, USA
| | - Kelly Eh Leguineche
- The Knight Campus for Accelerating Scientific Impact, University of Oregon, Eugene, OR, USA
| | - Sudhanshu Shekhar
- The Knight Campus for Accelerating Scientific Impact, University of Oregon, Eugene, OR, USA
| | - William R Walsh
- Surgical and Orthopedic Research Laboratories, University of New South Wales, Sydney, New South Wales, Australia
| | - Robert E Guldberg
- The Knight Campus for Accelerating Scientific Impact, University of Oregon, Eugene, OR, USA
| | - Ken Gall
- Department of Biomedical Engineering, Duke University, Durham, NC, USA; Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
| |
Collapse
|
41
|
Spece H, Basgul C, Andrews CE, MacDonald DW, Taheri ML, Kurtz SM. A systematic review of preclinical in vivo testing of 3D printed porous Ti6Al4V for orthopedic applications, part I: Animal models and bone ingrowth outcome measures. J Biomed Mater Res B Appl Biomater 2021; 109:1436-1454. [PMID: 33484102 DOI: 10.1002/jbm.b.34803] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 11/20/2020] [Accepted: 01/09/2021] [Indexed: 01/20/2023]
Abstract
For Ti6Al4V orthopedic and spinal implants, osseointegration is often achieved using complex porous geometries created via additive manufacturing (AM). While AM porous titanium (pTi) has shown clinical success, concerns regarding metallic implants have spurred interest in alternative AM biomaterials for osseointegration. Insights regarding the evaluation of these new materials may be supported by better understanding the role of preclinical testing for AM pTi. We therefore asked: (a) What animal models have been most commonly used to evaluate AM porous Ti6Al4V for orthopedic bone ingrowth; (b) What were the primary reported quantitative outcome measures for these models; and (c) What were the bone ingrowth outcomes associated with the most frequently used models? We performed a systematic literature search and identified 58 articles meeting our inclusion criteria. We found that AM pTi was evaluated most often using rabbit and sheep femoral condyle defect (FCD) models. Additional ingrowth models including transcortical and segmental defects, spinal fusions, and calvarial defects were also used with various animals based on the study goals. Quantitative outcome measures determined via histomorphometry including ''bone ingrowth'' (range: 3.92-53.4% for rabbit/sheep FCD) and bone-implant contact (range: 9.9-59.7% for rabbit/sheep FCD) were the most common. Studies also used 3D imaging to report outcomes such as bone volume fraction (BV/TV, range: 4.4-61.1% for rabbit/sheep FCD), and push-out testing for outcomes such as maximum removal force (range: 46.6-3092 N for rabbit/sheep FCD). Though there were many commonalities among the study methods, we also found significant heterogeneity in the outcome terms and definitions. The considerable diversity in testing and reporting may no longer be necessary considering the reported success of AM pTi across all model types and the ample literature supporting the rabbit and sheep as suitable small and large animal models, respectively. Ultimately, more standardized animal models and reporting of bone ingrowth for porous AM materials will be useful for future studies.
Collapse
Affiliation(s)
- Hannah Spece
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | - Cemile Basgul
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | | | - Daniel W MacDonald
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | | | - Steven M Kurtz
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.,Exponent, Inc., Philadelphia, Pennsylvania, USA
| |
Collapse
|
42
|
Li Z, Chen Z, Chen X, Zhao R. Effect of unit configurations and parameters on the properties of Ti-6Al-4V unit-stacked scaffolds: A trade-off between mechanical and permeable performance. J Mech Behav Biomed Mater 2021; 116:104332. [PMID: 33578077 DOI: 10.1016/j.jmbbm.2021.104332] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 12/24/2020] [Accepted: 01/12/2021] [Indexed: 11/30/2022]
Abstract
Scaffolds in tissue engineering can be created or printed nowadays with various structures that consist of a number of three-dimensional (3D) units stacked together periodically. The performance or properties of such scaffolds can be affected by the unit configurations and parameters, which, however, has not been well investigated and elucidated. This paper presents our study on the influence of unit configuration and parameters on the scaffolds performance by taking triply periodic minimal surfaces (TPMS) as the basic unit. The normalized values of elastic modulus, shear modulus and permeability were used to characterize the scaffold performance and analyzed by means of finite element analysis and CFD simulation, with focus on identifying the influence of unit configurations and parameters on the scaffold mechanical and permeable properties. Furthermore, by selective laser melting (SLM) printing technique, the cubic Primitive and IWP scaffolds with an oversize of 12 mm (2 × 2 × 2 units) were created and subjected to compressive tests. Both simulation and experiment results are in agreement to illustrate that unit configuration and parameters have significant influence on the mechanical and permeable properties of TPMS units. The methods and findings in the present work would serve as the base or rationales to regulate the unit configurations and parameters with trade-off solutions for given tissue engineering application.
Collapse
Affiliation(s)
- Zhitong Li
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, 150000, Heilongjiang, China
| | - Zhaobo Chen
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, 150000, Heilongjiang, China.
| | - Xiongbiao Chen
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, S7N5A9, Canada
| | - Runchao Zhao
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, 150000, Heilongjiang, China
| |
Collapse
|
43
|
Huang L, Cai B, Huang Y, Wang J, Zhu C, Shi K, Song Y, Feng G, Liu L, Zhang L. Comparative Study on 3D Printed Ti6Al4V Scaffolds with Surface Modifications Using Hydrothermal Treatment and Microarc Oxidation to Enhance Osteogenic Activity. ACS OMEGA 2021; 6:1465-1476. [PMID: 33490806 PMCID: PMC7818615 DOI: 10.1021/acsomega.0c05191] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 12/28/2020] [Indexed: 02/08/2023]
Abstract
![]()
Titanium (Ti) and
its alloys have been widely used in clinics as
preferred materials for bone tissue repair and replacement. However,
the lack of biological activity of Ti limits its clinical applications.
Surface modification of Ti with bioactive elements has always been
a research hotspot. In this study, to promote the osseointegration
of Ti6Al4V (Ti64) implants, calcium (Ca), oxygen (O), and phosphorus
(P) codoped multifunctional micro–nanohybrid coatings were
prepared on a three-dimensional (3D) printed porous Ti64 surface by
microarc oxidation (MAO) and a hydrothermal method (HT). The surface
morphologies, chemical compositions, and surface/cell interactions
of the obtained coatings were studied. In vitro experiments
indicated that all hybrid coating-modified Ti64 implants could enhance
protein adsorption and MC3T3 osteoblasts’ activity, adhesion,
and differentiation ability. In vivo experiments
showed that the hybrid coating promoted early osseointegration. By
comparison, microarc oxidation-treated Ti64 (M-Ti) has the best biological
activity and the strongest ability of osseointegration. It provides
important theoretical significance and potential application prospects
for improving the biological activity of Ti implants.
Collapse
Affiliation(s)
- Leizhen Huang
- Department of Orthopedic Surgery and Orthopedic Research Institue, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Bianyun Cai
- College of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang, Henan 471026, China
| | - Yong Huang
- Department of Orthopedic Surgery and Orthopedic Research Institue, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Jingcheng Wang
- Department of Orthopedic Surgery and Orthopedic Research Institue, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Ce Zhu
- Department of Orthopedic Surgery and Orthopedic Research Institue, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Kun Shi
- Department of Orthopedic Surgery and Orthopedic Research Institue, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Yueming Song
- Department of Orthopedic Surgery and Orthopedic Research Institue, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Ganjun Feng
- Department of Orthopedic Surgery and Orthopedic Research Institue, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Limin Liu
- Department of Orthopedic Surgery and Orthopedic Research Institue, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Li Zhang
- Analytical and Testing Center, Sichuan University, Chengdu, Sichuan 610065, China
| |
Collapse
|
44
|
In vivo study of conductive 3D printed PCL/MWCNTs scaffolds with electrical stimulation for bone tissue engineering. Biodes Manuf 2021. [DOI: 10.1007/s42242-020-00116-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
AbstractCritical bone defects are considered one of the major clinical challenges in reconstructive bone surgery. The combination of 3D printed conductive scaffolds and exogenous electrical stimulation (ES) is a potential favorable approach for bone tissue repair. In this study, 3D conductive scaffolds made with biocompatible and biodegradable polycaprolactone (PCL) and multi-walled carbon nanotubes (MWCNTs) were produced using the extrusion-based additive manufacturing to treat large calvary bone defects in rats. Histology results show that the use of PCL/MWCNTs scaffolds and ES contributes to thicker and increased bone tissue formation within the bone defect. Angiogenesis and mineralization are also significantly promoted using high concentration of MWCNTs (3 wt%) and ES. Moreover, scaffolds favor the tartrate-resistant acid phosphatase (TRAP) positive cell formation, while the addition of MWCNTs seems to inhibit the osteoclastogenesis but present limited effects on the osteoclast functionalities (receptor activator of nuclear factor κβ ligand (RANKL) and osteoprotegerin (OPG) expressions). The use of ES promotes the osteoclastogenesis and RANKL expressions, showing a dominant effect in the bone remodeling process. These results indicate that the combination of 3D printed conductive PCL/MWCNTs scaffold and ES is a promising strategy to treat critical bone defects and provide a cue to establish an optimal protocol to use conductive scaffolds and ES for bone tissue engineering.
Collapse
|
45
|
Longhitano GA, Conde A, Arenas MA, Jardini AL, Zavaglia CADC, Maciel Filho R, de Damborenea JJ. Corrosion resistance improvement of additive manufactured scaffolds by anodizing. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2020.137423] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
46
|
Design and performance evaluation of additively manufactured composite lattice structures of commercially pure Ti (CP-Ti). Bioact Mater 2020; 6:1215-1222. [PMID: 33210019 PMCID: PMC7653235 DOI: 10.1016/j.bioactmat.2020.10.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 10/10/2020] [Accepted: 10/10/2020] [Indexed: 12/15/2022] Open
Abstract
Ti alloys with lattice structures are garnering more and more attention in the field of bone repair or regeneration due to their superior structural, mechanical, and biological properties. In this study, six types of composite lattice structures with different strut radius that consist of simple cubic (structure A), body-centered cubic (structure B), and edge-centered cubic (structure C) unit cells are designed. The designed structures are firstly simulated and analysed by the finite element (FE) method. Commercially pure Ti (CP–Ti) lattice structures with optimized unit cells and strut radius are then fabricated by selective laser melting (SLM), and the dimensions, microtopography, and mechanical properties are characterised. The results show that among the six types of composite lattice structures, combined BA, CA, and CB structures exhibit smaller maximum von-Mises stress, indicating that these structures have higher strength. Based on the fitting curves of stress/specific surface area versus strut radius, the optimized strut radius of BA, CA, and CB structures is 0.28, 0.23, and 0.30 mm respectively. Their corresponding compressive yield strength and compressive modulus are 42.28, 30.11, and 176.96 MPa, and 4.13, 2.16, and 7.84 GPa, respectively. The CP-Ti with CB unit structure presents a similar strength and compressive modulus to the cortical bone, which makes it a potential candidate for subchondral bone restorations. Six types of graded lattice structures with different strut radius are designed and simulated by the FE method. BA, CA, and CB structures exhibit smaller maximum Von-Mises stress among six type structures. CP-Ti with CB structures exhibits similar mechanical properties to the cortical bone. Excellent properties make CP-Ti with CB structures an attractive subchondral bone restoration material.
Collapse
|
47
|
Feng X, Ma L, Liang H, Liu X, Lei J, Li W, Wang K, Song Y, Wang B, Li G, Li S, Yang C. Osteointegration of 3D-Printed Fully Porous Polyetheretherketone Scaffolds with Different Pore Sizes. ACS OMEGA 2020; 5:26655-26666. [PMID: 33110992 PMCID: PMC7581231 DOI: 10.1021/acsomega.0c03489] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Accepted: 09/10/2020] [Indexed: 05/02/2023]
Abstract
Polyetheretherketone (PEEK) constitutes a preferred alternative material for orthopedic implants owing to its good mechanical properties and biocompatibility. However, the poor osseointegration property of PEEK implants has limited their clinical applications. To address this issue, in this study, we investigated the mechanical and biological properties of fully porous PEEK scaffolds with different pore sizes both in vitro and in vivo. PEEK scaffolds with designed pore sizes of 300, 450, and 600 μm and a porosity of 60% were manufactured via fused deposition modeling (FDM) to explore the optimum pore size. Smooth solid PEEK cylinders (PEEK-S) were used as the reference material. The mechanical, cytocompatibility, proliferative, and osteogenic properties of PEEK scaffolds were characterized in comparison to those of PEEK-S. In vivo dynamic contrast-enhanced magnetic resonance imaging, microcomputed tomography, and histological observation were performed after 4 and 12 weeks of implantation to evaluate the microvascular perfusion and bone formation afforded by the various PEEK implants using a New Zealand white rabbit model with distal femoral condyle defects. Results of in vitro testing supported the good biocompatibility of the porous PEEK scaffolds manufactured via FDM. In particular, the PEEK-450 scaffolds were most beneficial for cell adhesion, proliferation, and osteogenic differentiation. Results of in vivo analysis further indicated that PEEK-450 scaffolds exhibited preferential potential for bone ingrowth and vascular perfusion. Together, our findings support that porous PEEK implants designed with a suitable pore size and fabricated via three-dimensional printing constitute promising alternative biomaterials for bone grafting and tissue engineering applications with marked potential for clinical applications.
Collapse
Affiliation(s)
- Xiaobo Feng
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Liang Ma
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Hang Liang
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Xiaoming Liu
- Department
of Radiology, Union Hospital, Tongji Medical
College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Jie Lei
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Wenqiang Li
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Kun Wang
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Yu Song
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Bingjin Wang
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Gaocai Li
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Shuai Li
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Cao Yang
- Department
of Orthopaedics, Union Hospital, Tongji
Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| |
Collapse
|
48
|
Yu Y, Wang Y, Zhang W, Wang H, Li J, Pan L, Han F, Li B. Biomimetic periosteum-bone substitute composed of preosteoblast-derived matrix and hydrogel for large segmental bone defect repair. Acta Biomater 2020; 113:317-327. [PMID: 32574859 DOI: 10.1016/j.actbio.2020.06.030] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 06/15/2020] [Accepted: 06/16/2020] [Indexed: 12/12/2022]
Abstract
Repairing large segmental bone defects above a critical size remains challenging with high risk of delayed union or even non-union. From the perspective of bone development and clinical experience, periosteum plays an indispensable role in bone repair and reconstruction. In this study, we explored the feasibility of using preosteoblast-derived matrix (pODM) as a biomimetic periosteum. By culturing MC3T3-E1 cell sheet on poly(dimethylsiloxane) and performing decellularization, an integral cell-free sheet of pODM could be readily harvested. Bone marrow mesenchymal stem cells (BMSCs) adhered and proliferated well on pODM. In addition, pODM exhibited a chemotactic effect on BMSCs in a concentration-dependent manner and also promoted osteogenic differentiation of BMSCs. Following that, pODM was wrapped around a gelatin methacryloyl (GelMA) hydrogel to construct an engineered periosteum-bone substitute. A rabbit radius segmental bone defect model was used to examine the bone repair efficacy of pODM/GelMA. Upon implantation of pODM/GelMA construct for 12 weeks, the critical-sized bone defects completely healed with remarkable full reconstruction of medullary cavity at the radial diaphysis. Together, this work proposes a high potency of using precursor cell-derived matrix as a biomimetic periosteum, which preserves the beneficial biological factors while avoids the limitations of using exogenous cells for bone regeneration. Combining precursor cell-derived matrix with hydrogel may provide a promising periosteum-bone biomimetic substitute for bone repair. STATEMENT OF SIGNIFICANCE: Repairing large segmental bone defects above a critical size remains challenging. As the periosteum plays an essential role in bone repair, this study aimed to explore the use of preosteoblast-derived matrix (pODM), harvested from decellularized MC3T3-E1 cell sheet, as a biomimetic periosteum to facilitate bone repair. We found that in vitro, pODM exhibited considerable chemotactic effect and osteogenic induction capability to bone marrow mesenchymal stem cells (BMSCs). In vivo, implantation of pODM/gelatin methacryloyl (GelMA) constructs as engineered periosteum-bone substitutes effectively repaired the critical-sized segmental bone defects at rabbit radius. Surprisingly, remarkable full reconstruction of medullary cavity at the diaphysis was achieved. Therefore, combining pODM with hydrogel may provide a promising biomimetic substitute for bone repair.
Collapse
|
49
|
Zhang L, Song B, Yang L, Shi Y. Tailored mechanical response and mass transport characteristic of selective laser melted porous metallic biomaterials for bone scaffolds. Acta Biomater 2020; 112:298-315. [PMID: 32504689 DOI: 10.1016/j.actbio.2020.05.038] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 05/03/2020] [Accepted: 05/27/2020] [Indexed: 02/08/2023]
Abstract
Porous metallic biomaterials developed from pentamode metamaterials (PMs) were rationally designed to mimic the topological, mechanical, and mass transport properties of human bones. Here, a series of diamond-based PMs with different strut parameters were fabricated from a Ti-6Al-4V powder by selective laser melting (SLM) technique. The morphological features, mechanical properties and permeability of PM samples were then characterized. In terms of morphology, the as-built PMs were well consistent with the as-designed ones, although the slight surface deviations were presented in overhanging areas. The PM scaffolds showed a switchable deformation pattern controlled by the slenderness ratio of struts. The double-cone strut topology increases the tortuosity and thereby accelerates the nutrients supply, waste removal, and cell migration to the whole scaffold region and circumambient bone tissue. The measured mechanical properties (i.e., E: 0.59-2.90 GPa, σy: 20.59-112.63 MPa) and computational permeability values (k: 9.87-49.19 × 10-9 m2) of PM scaffolds were all in accordance with those of trabecular bone. The experimental permeability values were linearly dependent on the results of simulations. This study showed the great potential of PMs as bone scaffolds. Moreover, we demonstrated that PM-based porous biomaterials can decouple the mass transport and mechanical properties of bone scaffolds, so as to achieve an unprecedented level of tailoring their multi-physics properties. STATEMENT OF SIGNIFICANCE: The topological diversity can significantly improve the adaptability of the implant to the primary bone tissue. Previous studies revealed that the mechanical and mass transport properties of porous biomaterials are correlated to the material types, porosities and lattice topologies but neglected effects of strut design. We show here the influence of strut morphology on the mechanical and mass transport properties which are independently tailored, that is, the mass transport properties can be markedly increased while maintaining the mechanical properties of mimicking specific bones, vice versa. This study emphasizes the importance of strut topological design in the development of AM porous biomaterials.
Collapse
|
50
|
Veronesi F, Martini L, Giavaresi G, Fini M. Bone regenerative medicine: metatarsus defects in sheep to evaluate new therapeutic strategies for human long bone defect. A systematic review. Injury 2020; 51:1457-1467. [PMID: 32430197 DOI: 10.1016/j.injury.2020.04.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 04/01/2020] [Accepted: 04/08/2020] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Large bone defects in long bone are not able to repair themselves and require grafts. Although autograft is the gold standard, it is associated with some disadvantages. Consequently, the application of tissue engineering (TE) techniques help with the use of allogenic biological and artificial scaffolds, cells and growth factors (GFs). Following 3Rs and in vitro testing strategies, animal models are required in preclinical in vivo studies to evaluate the therapeutic effects of the most promising TE techniques. MATERIALS AND METHODS A systematic review was performed from 2000 to 2019 to evaluate bone regeneration sheep metatarsus defects. RESULTS Eleven in vivo studies on sheep metatarsus defect were retrieved. The mid-diaphysis of metatarsus was the region most employed to perform critical size defects. Natural, synthetic and hybrid scaffolds were implanted, combined with bone marrow mesenchymal stem cells (BMSCs), GFs such as osteogenic protein 1 (OP1) and platelet rich plasma (PRP). The maximum follow-up period was 4 and 6 months in which radiography, histology, histomorphometry, computed tomography (CT) and biomechanics were performed to evaluate the healing status. CONCLUSIONS the sheep metatarsus defect model seems to be a suitable environment with a good marriage of biological and biomechanical properties. Defects of 3 cm are treated with natural scaffolds (homologous graft or allografts), those of 2.5 cm with natural, synthetic or composite scaffolds, while little defects (0.5 × 0.5 cm) with composite scaffolds. No difference in results is found regardless of the defect size.
Collapse
Affiliation(s)
- Francesca Veronesi
- Laboratory of Preclinical and Surgical Studies, IRCCS-Istituto Ortopedico Rizzoli, Via Di Barbiano 1/10, 40136 Bologna, Italy.
| | - Lucia Martini
- Laboratory of Preclinical and Surgical Studies, IRCCS-Istituto Ortopedico Rizzoli, Via Di Barbiano 1/10, 40136 Bologna, Italy.
| | - Gianluca Giavaresi
- Laboratory of Preclinical and Surgical Studies, IRCCS-Istituto Ortopedico Rizzoli, Via Di Barbiano 1/10, 40136 Bologna, Italy.
| | - Milena Fini
- Laboratory of Preclinical and Surgical Studies, IRCCS-Istituto Ortopedico Rizzoli, Via Di Barbiano 1/10, 40136 Bologna, Italy.
| |
Collapse
|