1
|
Vanaei S, Hashemi M, Solouk A, Asghari Ilani M, Amili O, Hefzy MS, Tang Y, Elahinia M. Manufacturing, Processing, and Characterization of Self-Expanding Metallic Stents: A Comprehensive Review. Bioengineering (Basel) 2024; 11:983. [PMID: 39451359 PMCID: PMC11505524 DOI: 10.3390/bioengineering11100983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Revised: 08/31/2024] [Accepted: 09/03/2024] [Indexed: 10/26/2024] Open
Abstract
This paper aims to review the State of the Art in metal self-expanding stents made from nitinol (NiTi), showing shape memory and superelastic behaviors, to identify the challenges and the opportunities for improving patient outcomes. A significant contribution of this paper is its extensive coverage of multidisciplinary aspects, including design, simulation, materials development, manufacturing, bio/hemocompatibility, biomechanics, biomimicry, patency, and testing methodologies. Additionally, the paper offers in-depth insights into the latest practices and emerging trends, with a special emphasis on the transformative potential of additive manufacturing techniques in the development of metal stents. By consolidating existing knowledge and highlighting areas for future innovation, this review provides a valuable roadmap for advancing nitinol stents.
Collapse
Affiliation(s)
- Saeedeh Vanaei
- Mechanical Industrial and Manufacturing Engineering Department, University of Toledo, Toledo, OH 43606, USA; (O.A.); (M.S.H.); (M.E.)
| | - Mahdi Hashemi
- Department of Materials and Metallurgical Engineering, Amirkabir University of Technology, Tehran 1591634311, Iran;
| | - Atefeh Solouk
- Biomedical Engineering Department, Amirkabir University of Technology (Tehran Polytechnic), Tehran 1591634311, Iran;
| | - Mohsen Asghari Ilani
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 1439957131, Iran;
| | - Omid Amili
- Mechanical Industrial and Manufacturing Engineering Department, University of Toledo, Toledo, OH 43606, USA; (O.A.); (M.S.H.); (M.E.)
| | - Mohamed Samir Hefzy
- Mechanical Industrial and Manufacturing Engineering Department, University of Toledo, Toledo, OH 43606, USA; (O.A.); (M.S.H.); (M.E.)
| | - Yuan Tang
- Department of Bioengineering, University of Toledo, Toledo, OH 43606, USA;
| | - Mohammad Elahinia
- Mechanical Industrial and Manufacturing Engineering Department, University of Toledo, Toledo, OH 43606, USA; (O.A.); (M.S.H.); (M.E.)
| |
Collapse
|
2
|
Rao J, Gao H, Sun J, Yu R, Zhao D, Ding Y. A Critical Review of Biodegradable Zinc Alloys toward Clinical Applications. ACS Biomater Sci Eng 2024; 10:5454-5473. [PMID: 39082869 DOI: 10.1021/acsbiomaterials.4c00210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/03/2024]
Abstract
Biodegradable zinc (Zn) alloys stand out as promising contenders for biomedical applications due to their favorable mechanical properties and appropriate degradation rates, offering the potential to mitigate the risks and expenses associated with secondary surgeries. While current research predominantly centers on the in vitro examination of Zn alloys, notable disparities often emerge between in vivo and in vitro findings. Consequently, conducting in vivo investigations on Zn alloys holds paramount significance in advancing their clinical application. Different element compositions and processing methods decide the mechanical properties and biological performance of Zn alloys, thus affecting their suitability for specific medical applications. This paper presents a comprehensive overview of recent strides in the development of biodegradable Zn alloys, with a focus on key aspects such as mechanical properties, toxicity, animal experiments, biological properties, and molecular mechanisms. By summarizing these advancements, the paper aims to broaden the scope of research directions and enhance the understanding of the clinical applications of biodegradable Zn alloys.
Collapse
Affiliation(s)
- Jiahui Rao
- Department of Stomatology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- School of Stomatology, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
- Hubei Province Key Laboratory of Oral and Maxillofacial Development and Regeneration, Wuhan, 430022, China
| | - Hairui Gao
- School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Jiwei Sun
- Department of Stomatology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- School of Stomatology, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
- Hubei Province Key Laboratory of Oral and Maxillofacial Development and Regeneration, Wuhan, 430022, China
| | - Ran Yu
- Department of Stomatology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- School of Stomatology, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
- Hubei Province Key Laboratory of Oral and Maxillofacial Development and Regeneration, Wuhan, 430022, China
| | - Danlei Zhao
- Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China
| | - Yumei Ding
- Department of Stomatology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- School of Stomatology, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
- Hubei Province Key Laboratory of Oral and Maxillofacial Development and Regeneration, Wuhan, 430022, China
| |
Collapse
|
3
|
Zhang X, Niu J, Yeung KWK, Huang H, Gao Z, Chen C, Guan Q, Zhang G, Zhang L, Xue G, Yuan G. Developing Zn-2Cu-xLi (x < 0.1 wt %) alloys with suitable mechanical properties, degradation behaviors and cytocompatibility for vascular stents. Acta Biomater 2024:S1742-7061(24)00313-1. [PMID: 38876454 DOI: 10.1016/j.actbio.2024.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 05/30/2024] [Accepted: 06/06/2024] [Indexed: 06/16/2024]
Abstract
Biodegradable Zn alloys show great potential for vascular stents due to their moderate degradation rates and acceptable biocompatibility. However, the poor mechanical properties limit their applications. In this study, low alloyed Zn-2Cu-xLi (x = 0.004, 0.01, 0.07 wt %) alloys with favorable mechanical properties were developed. The microstructure consists of fine equiaxed η-Zn grains, micron, submicron-sized and coherent nano ε-CuZn4 phases. The introduced Li exists as a solute in the η-Zn matrix and ε-CuZn4 phase, and results in the increase of ε-CuZn4 volume fraction, the refinement of grains and more uniform distribution of grain sizes. As Li content increases, the strength of alloys is dramatically improved by grain boundary strengthening, precipitate strengthening of ε-CuZn4 and solid solution strengthening of Li. Zn-2Cu-0.07Li alloy has the optimal mechanical properties with a tensile yield strength of 321.8 MPa, ultimate tensile strength of 362.3 MPa and fracture elongation of 28.0 %, exceeding the benchmark of stents. It also has favorable mechanical property stability, weak tension compression yield asymmetry and strain rate sensitivity. It exhibits uniform degradation and a little improved degradation rate of 89.5 μm∙year-1, due to the improved electrochemical activity by increased ε-CuZn4 volume fraction, and generates Li2CO3 and LiOH. It shows favorable cytocompatibility without adverse influence on endothelial cell viability by trace Li+. The fabricated microtubes show favorable mechanical properties, and stents exhibit an average radial strength of 118 kPa. The present study indicates that Zn-2Cu-0.07Li alloy is a potential and promising candidate for vascular stent applications. STATEMENT OF SIGNIFICANCE: Zn alloys are promising candidates for biodegradable vascular stents. However, improving their mechanical properties is challenging. Combining the advantages of Cu and trace Li, Zn-2Cu-xLi (x < 0.1 wt %) alloys were developed for stents. As Li increases, the strength of alloys is dramatically improved by refined grains, increased volume fraction of ε-CuZn4 and solid solution of Li. Zn-2Cu-0.07Li alloy exhibits a TYS exceeding 320 MPa, UTS exceeding 360 MPa and fracture EL of nearly 30 %. It shows favorable mechanical stability, degradation behaviors and cytocompatibility. The alloy was fabricated into microtubes and stents for mechanical property tests to verify application feasibility for the first time. This indicates that Zn-2Cu-0.07Li alloy has great potential for vascular stent applications.
Collapse
Affiliation(s)
- Xiyuan Zhang
- National Engineering Research Center of Light Alloy Net Forming and State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Jialin Niu
- National Engineering Research Center of Light Alloy Net Forming and State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| | - Kelvin Wai-Kwok Yeung
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam, Hong Kong 999077, China
| | - Hua Huang
- National Engineering Research Center of Light Alloy Net Forming and State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Zhiqiang Gao
- National Engineering Research Center of Light Alloy Net Forming and State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Chun Chen
- National Engineering Research Center of Light Alloy Net Forming and State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Qingqing Guan
- National Engineering Research Center of Light Alloy Net Forming and State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Guangjian Zhang
- Shanghai MicroPort Endovascular MedTech (Group) Co., Ltd., Shanghai 200120, China
| | - Linlin Zhang
- Shanghai MicroPort Endovascular MedTech (Group) Co., Ltd., Shanghai 200120, China
| | - Guanhua Xue
- Department of Vascular Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.
| | - Guangyin Yuan
- National Engineering Research Center of Light Alloy Net Forming and State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| |
Collapse
|
4
|
Zhou Y, Zhang A, Wu J, Guo S, Sun Q. Application and Perspectives: Magnesium Materials in Bone Regeneration. ACS Biomater Sci Eng 2024; 10:3514-3527. [PMID: 38723173 PMCID: PMC11167594 DOI: 10.1021/acsbiomaterials.3c01713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 04/20/2024] [Accepted: 04/22/2024] [Indexed: 06/11/2024]
Abstract
The field of bone regeneration has always been a hot and difficult research area, and there is no perfect strategy at present. As a new type of biodegradable material, magnesium alloys have excellent mechanical properties and bone promoting ability. Compared with other inert metals, magnesium alloys have significant advantages and broad application prospects in the field of bone regeneration. By searching the official Web sites and databases of various funds, this paper summarizes the research status of magnesium composites in the field of bone regeneration and introduces the latest scientific research achievements and clinical transformations of scholars in various countries and regions, such as improving the corrosion resistance of magnesium alloys by adding coatings. Finally, this paper points out the current problems and challenges, aiming to provide ideas and help for the development of new strategies for the treatment of bone defects and fractures.
Collapse
Affiliation(s)
| | | | - Jibin Wu
- Department of Plastic Surgery, The First Hospital of China Medical University, 110001 Shenyang, Liaoning Province, PR China
| | - Shu Guo
- Department of Plastic Surgery, The First Hospital of China Medical University, 110001 Shenyang, Liaoning Province, PR China
| | - Qiang Sun
- Department of Plastic Surgery, The First Hospital of China Medical University, 110001 Shenyang, Liaoning Province, PR China
| |
Collapse
|
5
|
Chandra G, Pandey A, Singh AK, Singh G, Tipan N. Finite element method-based simulation on bone fracture fixation configuration factors for biodegradable embossed locking compression plate. Comput Methods Biomech Biomed Engin 2024; 27:951-963. [PMID: 37255261 DOI: 10.1080/10255842.2023.2217708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Accepted: 05/19/2023] [Indexed: 06/01/2023]
Abstract
As an evolution, biodegradable implants need to maximize mechanical performance thereby may lead to confusion in selection of the biodegradable material and implant design to the fracture site. This requires selecting a unique fixation configuration to fit within the fractured bone, factors of which can be bone-plate clearance, interfragmentary gap, alteration in screw fixation position and variation in the number of screws whose configuration optimization can re-maximize the mechanical performance of the biodegradable implant. Therefore, these factors have been optimized based on the induced minimum stress using the finite element method-based simulation for which biodegradable embossed locking plates (BELCP) via screws made of Mg-alloy have been fitted over two fragments of femur body (as hollow cylindrical cortical bone). An average human weight of 62 kg is applied to one segment of the femur for all different configurations of each factor, where another segment is assumed to be fixed. By this simulation, the most optimal fixation configuration was found at a minimum induced stress value of 41.96 MPa which is approximately 85%, 18%, 6% and 48% respectively less than all maximum stress induced configurations in each of the factor. This optimized configuration was at the minimum clearance between bone and plate with a 3 mm interfragmentary gap using 8 screws where the locking screw begins to apply from the center of the BELCP. Overall, BELCP may be a better biodegradable implant plate for bone fracture fixation with these optimized fixation configurations as the improved mechanical performance after experimental validation.
Collapse
Affiliation(s)
- Girish Chandra
- Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, India
| | - Ajay Pandey
- Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, India
| | - Ashish Kumar Singh
- Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, India
| | - Gourav Singh
- Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, India
| | - Nilesh Tipan
- Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, India
| |
Collapse
|
6
|
Wu W, Banga A, Oguz UM, Zhao S, Thota AK, Gadamidi VK, Dasari VS, Samant S, Watanabe Y, Murasato Y, Chatzizisis YS. Experimental validation and clinical feasibility of 3D reconstruction of coronary artery bifurcation stents using intravascular ultrasound. PLoS One 2024; 19:e0300098. [PMID: 38625996 PMCID: PMC11020600 DOI: 10.1371/journal.pone.0300098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 02/22/2024] [Indexed: 04/18/2024] Open
Abstract
The structural morphology of coronary stents and the local hemodynamic environment following stent deployment in coronary arteries are crucial determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to facilitate geometrically accurate three-dimensional (3D) reconstruction of coronary stents. This work presents an innovative algorithm for the 3D reconstruction of coronary artery stents, leveraging intravascular ultrasound (IVUS) and angiography. The accuracy and reproducibility of our method were tested in stented patient-specific silicone models, with micro-computed tomography serving as a reference standard. We also evaluated the clinical feasibility and ability to perform computational fluid dynamics (CFD) studies in a clinically stented coronary bifurcation. Our experimental and clinical studies demonstrated that our proposed algorithm could reproduce the complex 3D stent configuration with a high degree of precision and reproducibility. Moreover, the algorithm was proved clinically feasible in cases with stents deployed in a diseased coronary artery bifurcation, enabling CFD studies to assess the hemodynamic environment. In combination with patient-specific CFD studies, our method can be applied to stenting optimization, training in stenting techniques, and advancements in stent research and development.
Collapse
Affiliation(s)
- Wei Wu
- Cardiovascular Division, Center for Digital Cardiovascular Innovations, University of Miami Miller School of Medicine, Miami, Florida, United States of America
| | - Akshat Banga
- Cardiovascular Division, Center for Digital Cardiovascular Innovations, University of Miami Miller School of Medicine, Miami, Florida, United States of America
| | - Usama M. Oguz
- Cardiovascular Division, Center for Digital Cardiovascular Innovations, University of Miami Miller School of Medicine, Miami, Florida, United States of America
| | - Shijia Zhao
- Cardiovascular Division, Center for Digital Cardiovascular Innovations, University of Miami Miller School of Medicine, Miami, Florida, United States of America
| | - Anjani Kumar Thota
- Cardiovascular Division, Center for Digital Cardiovascular Innovations, University of Miami Miller School of Medicine, Miami, Florida, United States of America
| | - Vinay Kumar Gadamidi
- Cardiovascular Division, Center for Digital Cardiovascular Innovations, University of Miami Miller School of Medicine, Miami, Florida, United States of America
| | - Vineeth S. Dasari
- Cardiovascular Division, Center for Digital Cardiovascular Innovations, University of Miami Miller School of Medicine, Miami, Florida, United States of America
| | - Saurabhi Samant
- Cardiovascular Division, Center for Digital Cardiovascular Innovations, University of Miami Miller School of Medicine, Miami, Florida, United States of America
| | - Yusuke Watanabe
- Department of Cardiology, Teikyo University School of Medicine, Tokyo, Japan
| | - Yoshinobu Murasato
- Department of Cardiology and Clinical Research Center, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan
| | - Yiannis S. Chatzizisis
- Cardiovascular Division, Center for Digital Cardiovascular Innovations, University of Miami Miller School of Medicine, Miami, Florida, United States of America
| |
Collapse
|
7
|
Jia T, Guines D, Laillé D, Leotoing L, Gloriant T. Finite element analysis of the mechanical performance of self-expanding endovascular stents made with new nickel-free superelastic β-titanium alloys. J Mech Behav Biomed Mater 2024; 151:106345. [PMID: 38215658 DOI: 10.1016/j.jmbbm.2023.106345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 12/13/2023] [Accepted: 12/22/2023] [Indexed: 01/14/2024]
Abstract
New Ni-free superelastic β-titanium alloys from the Ti-Zr-Nb-Sn system have been designed in this study to replace the NiTi alloy currently used for self-expanding endovascular stents. The simulation results, carried out by finite element analysis (FEA) on two β-type Ti-Zr-Nb-Sn alloys using a commonly used superelastic constitutive model, were in good agreement with the experimental uniaxial tension data. An ad-hoc self-expanding coronary stent was specifically designed for the present study. To assess the mechanical performance of the endovascular stents, a FEA framework of the stent deployed in the arterial system was established, and a simply cyclic bending loading was proposed. Six comparative simulations of three superelastic materials (including NiTi for comparison) and two arterial configurations were successfully conducted. The mechanical behaviours of the stents were analysed through stress localization, the increase in artery diameter, contact results, and distributions of mean and alternating strain. The simulation results show that the Ti-22Zr-11Nb-2Sn (at. %) alloy composition for the stent produces the largest contact area (9.92 mm2) and radial contact force (49.5 mN) on the inner surface of the plaque and a higher increase in the stenotic artery diameter (70 %) after three vascular bending cycles. Furthermore, the Ti-22Zr-11Nb-2Sn stent exhibited sufficient crimping capacity and reliable mechanical performance during deployment and cyclic bending, which could make it a suitable choice for self-expanding coronary stents. In this work, the implementation of finite element analysis has thus made it possible to propose a solid basis for the mechanical evaluation of these stents fabricated in new Ni-free superelastic β-Ti alloys.
Collapse
Affiliation(s)
- Tianyu Jia
- University of Rennes, INSA Rennes, CNRS UMR 6226 ISCR, 35000, Rennes, France
| | - Dominique Guines
- University of Rennes, INSA Rennes, LGCGM, EA 3913, 35000, Rennes, France
| | - Denis Laillé
- University of Rennes, INSA Rennes, CNRS UMR 6226 ISCR, 35000, Rennes, France
| | - Lionel Leotoing
- University of Rennes, INSA Rennes, LGCGM, EA 3913, 35000, Rennes, France
| | - Thierry Gloriant
- University of Rennes, INSA Rennes, CNRS UMR 6226 ISCR, 35000, Rennes, France.
| |
Collapse
|
8
|
Khatami M, Doniavi A, Abazari AM, Fotouhi M. Enhancing flexibility and strength-to-weight ratio of polymeric stents: A new variable-thickness design approach. J Mech Behav Biomed Mater 2024; 150:106262. [PMID: 38029464 DOI: 10.1016/j.jmbbm.2023.106262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 11/17/2023] [Accepted: 11/20/2023] [Indexed: 12/01/2023]
Abstract
This paper presents a new design strategy to improve the flexibility and strength-to-weight ratio of polymeric stents. The proposed design introduces a variable-thickness (VT) stent that outperforms conventional polymeric stents with constant thickness (CT). While polymeric stents offer benefits like flexibility and bioabsorption, their mechanical strength is lower compared to metal stents. To address this limitation, thicker polymer stents are used, compromising flexibility and clinical performance. Leveraging advancements in 3D printing, a new design approach is introduced in this study and is manufactured by the Liquid Crystal Display (LCD) 3D printing method and PLA resin. The mechanical performance of CT and VT stents is compared using the Finite Element Method (FEM), validated by experimental tests. Results demonstrate that the VT stent offers significant improvements compared to a CT stent in bending stiffness (over 20%), reduced plastic strain distribution of expansion (over 26%), and increased radial strength (over 10%). This research showcases the potential of the VT stent design to enhance clinical outcomes and patient care.
Collapse
Affiliation(s)
- Mohamad Khatami
- Department of Mechanical Engineering, Faculty of Engineering, Urmia University, Urmia, Iran.
| | - Ali Doniavi
- Department of Mechanical Engineering, Faculty of Engineering, Urmia University, Urmia, Iran.
| | - Amir Musa Abazari
- Department of Mechanical Engineering, Faculty of Engineering, Urmia University, Urmia, Iran.
| | - Mohammad Fotouhi
- Department of Materials, Mechanics, Management & Design (3MD), Faculty of Civil Engineering and Geosciences, Delft University of Technology, Delft, the Netherlands.
| |
Collapse
|
9
|
Forkmann C, Pritsch M, Baumann-Zumstein P, Lootz D, Joner M. In vivo chronic scaffolding force of a resorbable magnesium scaffold. J Biomech 2024; 164:111988. [PMID: 38364489 DOI: 10.1016/j.jbiomech.2024.111988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 01/31/2024] [Accepted: 02/05/2024] [Indexed: 02/18/2024]
Abstract
The aim of this study is to qualitatively characterize the in vivo chronic scaffolding force of the Magmaris® Resorbable Magnesium Scaffold (RMS). This important parameter of scaffolds must be balanced between sufficient radial support during the healing period of the vessel and avoidance of long-term vessel caging. A finite element model was established using preclinical animal data and used to predict the device diameter and scaffolding force up to 90 days after implantation. To account for scaffold resorption, it included backbone degradation as well as formation of discontinuities as observed in vivo. The predictions of the model regarding acute recoil and chronic development of the device diameter were in good agreement with the preclinical data, supporting the validity of the model. It was found that after 28 and 90 days, the Magmaris® RMS retained 90 % and 47 % of its initial scaffolding force, respectively. The reduction in scaffolding force was mainly driven by discontinuities in the meandering segments. Finite element analysis combined with preclinical data is a reliable method to characterize the chronic scaffolding force.
Collapse
Affiliation(s)
| | | | | | - Daniel Lootz
- Biotronik AG, Ackerstraße 6, 8180 Bülach, Switzerland.
| | - Michael Joner
- German Heart Center Munich, Lazarettstraße 36, 80636 München, Germany.
| |
Collapse
|
10
|
Menze R, Hesse B, Kusmierczuk M, Chen D, Weitkamp T, Bettink S, Scheller B. Synchrotron microtomography reveals insights into the degradation kinetics of bio-degradable coronary magnesium scaffolds. Bioact Mater 2024; 32:1-11. [PMID: 37771679 PMCID: PMC10522944 DOI: 10.1016/j.bioactmat.2023.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 08/18/2023] [Accepted: 09/12/2023] [Indexed: 09/30/2023] Open
Abstract
Bioresorbable magnesium scaffolds are a promising future treatment option for coronary artery stenosis, especially for young adults. Due to the degradation of these scaffolds (<1 year), long-term device-related clinical events could be reduced compared to treatments with conventional drug eluting stents. First clinical trials indicate a return of vasomotion after one year, which may be associated with improved long-term clinical outcomes. However, even after decades of development, the degradation process, ideal degradation time and biological response in vivo are still not fully understood. The present study investigates the in vivo degradation of magnesium scaffolds in the coronary arteries of pigs influenced by different strut thicknesses and the presence of antiproliferative drugs. Due to high 3D image contrast of synchrotron-based micro-CT with phase contrast (SR-μCT), a qualitative and quantitative evaluation of the degradation morphology of magnesium scaffolds was obtained. For the segmentation of the μCT images a convolutional network architecture (U-net) was exploited, demonstrating the huge potential of merging high resolution SR-μCT with deep learning (DL) supported data analysis. In total, 30 scaffolds, made of the rare earth alloy Resoloy®, with different strut designs were implanted into the coronary arteries of 10 domestic pigs for 28 days using drug-coated or uncoated angioplasty balloons for post-dilatation. The degradation morphology was analyzed using scanning electron microscopy, energy dispersive x-ray spectroscopy and SR-μCT. The data from these methods were then related to data from angiography, optical coherence tomography and histology. A thinner strut size (95 vs. 130 μm) and the presence of paclitaxel indicated a slower degradation rate at 28 d in vivo, which positively influences the late lumen loss (0.5 and 0.6 mm vs. 1.0 and 1.1 mm) and recoil values (0 and 1.7% vs. 6.1 and 22%).
Collapse
Affiliation(s)
- Roman Menze
- MeKo Manufacturing e.K., Im Kirchenfelde 12-14, 31157, Sarstedt, Germany
| | - Bernhard Hesse
- Xploraytion GmbH, Bismarckstr. 10-12, 10625, Berlin, Germany
| | | | - Duote Chen
- Xploraytion GmbH, Bismarckstr. 10-12, 10625, Berlin, Germany
| | - Timm Weitkamp
- Synchrotron SOLEIL, L'Orme des Merisiers, Départementale 128, 91190, Saint-Aubin, France
| | | | - Bruno Scheller
- Universität des Saarlandes, Campus Homburg, 66421, Homburg, Germany
| |
Collapse
|
11
|
Song Y, Li B, Chen H, Yu Z. Research progress of absorbable stents. Int J Med Sci 2024; 21:404-412. [PMID: 38169581 PMCID: PMC10758145 DOI: 10.7150/ijms.90012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Accepted: 12/02/2023] [Indexed: 01/05/2024] Open
Abstract
Atherosclerosis, a chronic inflammation of blood vessel walls, is a progressive pathophysiological process characterized by lipid deposition and innate adaptive immune responses. Arteriosclerosis often leads to narrowing of blood vessels. At present, interventional stent therapy is the main treatment method for vascular stenosis, which has the advantages of less trauma, less risk and faster recovery. However, atherosclerosis occurs in a complex pathophysiological environment. Stenting inevitably causes local tissue damage, leading to complications such as inflammation, intimal hyperplasia, late thrombosis, stent restenosis and other complications. It is urgent to optimize interventional therapy program. This article summarizes the advantages and disadvantages of absorbable metal scaffolds and the research progress of absorbable polymer scaffolds. The optimization strategy of stent is proposed. The status quo of drug coating was summarized. The prospect of new stent. To improve the therapeutic effect of arteriosclerosis.
Collapse
Affiliation(s)
- Ying Song
- Department of Neurovascular oncology Surgery, First Hospital of Jilin University, 1 Xinmin Avenue Changchun 130021, Jilin Province, China
| | - Bingwei Li
- Department of Neurovascular Surgery, First Hospital of Jilin University, 1 Xinmin Avenue Changchun 130021, Jilin Province, China
| | - Hao Chen
- Department of Neurovascular Surgery, First Hospital of Jilin University, 1 Xinmin Avenue Changchun 130021, Jilin Province, China
| | - Zhuyuan Yu
- Department of Neurovascular oncology Surgery, First Hospital of Jilin University, 1 Xinmin Avenue Changchun 130021, Jilin Province, China
| |
Collapse
|
12
|
Yang Y, Yang Y, Hou Z, Wang T, Wu P, Shen L, Li P, Zhang K, Yang L, Sun S. Comprehensive review of materials, applications, and future innovations in biodegradable esophageal stents. Front Bioeng Biotechnol 2023; 11:1327517. [PMID: 38125305 PMCID: PMC10731276 DOI: 10.3389/fbioe.2023.1327517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 11/27/2023] [Indexed: 12/23/2023] Open
Abstract
Esophageal stricture (ES) results from benign and malignant conditions, such as uncontrolled gastroesophageal reflux disease (GERD) and esophageal neoplasms. Upper gastrointestinal endoscopy is the preferred diagnostic approach for ES and its underlying causes. Stent insertion using an endoscope is a prevalent method for alleviating or treating ES. Nevertheless, the widely used self-expandable metal stents (SEMS) and self-expandable plastic stents (SEPS) can result in complications such as migration and restenosis. Furthermore, they necessitate secondary extraction in cases of benign esophageal stricture (BES), rendering them unsatisfactory for clinical requirements. Over the past 3 decades, significant attention has been devoted to biodegradable materials, including synthetic polyester polymers and magnesium-based alloys, owing to their exceptional biocompatibility and biodegradability while addressing the challenges associated with recurring procedures after BES resolves. Novel esophageal stents have been developed and are undergoing experimental and clinical trials. Drug-eluting stents (DES) with drug-loading and drug-releasing capabilities are currently a research focal point, offering more efficient and precise ES treatments. Functional innovations have been investigated to optimize stent performance, including unidirectional drug-release and anti-migration features. Emerging manufacturing technologies such as three-dimensional (3D) printing and new biodegradable materials such as hydrogels have also contributed to the innovation of esophageal stents. The ultimate objective of the research and development of these materials is their clinical application in the treatment of ES and other benign conditions and the palliative treatment of malignant esophageal stricture (MES). This review aimed to offer a comprehensive overview of current biodegradable esophageal stent materials and their applications, highlight current research limitations and innovations, and offer insights into future development priorities and directions.
Collapse
Affiliation(s)
- Yaochen Yang
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
- Research Center for Biomedical Materials, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Yuanyuan Yang
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Zhipeng Hou
- Research Center for Biomedical Materials, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Tingting Wang
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Peng Wu
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Lufan Shen
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Peng Li
- Liaoning Research Institute for Eugenic Birth and Fertility, China Medical University, Shenyang, China
| | - Kai Zhang
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Liqun Yang
- Research Center for Biomedical Materials, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
- Liaoning Research Institute for Eugenic Birth and Fertility, China Medical University, Shenyang, China
| | - Siyu Sun
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| |
Collapse
|
13
|
Kabirian F, Mozafari M, Mela P, Heying R. Incorporation of Controlled Release Systems Improves the Functionality of Biodegradable 3D Printed Cardiovascular Implants. ACS Biomater Sci Eng 2023; 9:5953-5967. [PMID: 37856240 DOI: 10.1021/acsbiomaterials.3c00559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2023]
Abstract
New horizons in cardiovascular research are opened by using 3D printing for biodegradable implants. This additive manufacturing approach allows the design and fabrication of complex structures according to the patient's imaging data in an accurate, reproducible, cost-effective, and quick manner. Acellular cardiovascular implants produced from biodegradable materials have the potential to provide enough support for in situ tissue regeneration while gradually being replaced by neo-autologous tissue. Subsequently, they have the potential to prevent long-term complications. In this Review, we discuss the current status of 3D printing applications in the development of biodegradable cardiovascular implants with a focus on design, biomaterial selection, fabrication methods, and advantages of implantable controlled release systems. Moreover, we delve into the intricate challenges that accompany the clinical translation of these groundbreaking innovations, presenting a glimpse of potential solutions poised to enable the realization of these technologies in the realm of cardiovascular medicine.
Collapse
Affiliation(s)
- Fatemeh Kabirian
- Cardiovascular Developmental Biology, Department of Cardiovascular Sciences, KU Leuven, Leuven 3000, Belgium
| | - Masoud Mozafari
- Research Unit of Health Sciences and Technology, Faculty of Medicine, University of Oulu, Oulu FI-90014, Finland
| | - Petra Mela
- Medical Materials and Implants, Department of Mechanical Engineering, Munich Institute of Biomedical Engineering, and TUM School of Engineering and Design, Technical University of Munich, Munich 80333, Germany
| | - Ruth Heying
- Cardiovascular Developmental Biology, Department of Cardiovascular Sciences, KU Leuven, Leuven 3000, Belgium
| |
Collapse
|
14
|
Wang Q, Huang S, Miao J, Chen Z, Li H, Zhao L, Yuan J. Impact of inverse unequal height strut structure on the functional performance of an additively manufactured cardiovascular stent. J Mech Behav Biomed Mater 2023; 146:106058. [PMID: 37549521 DOI: 10.1016/j.jmbbm.2023.106058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/29/2023] [Accepted: 07/31/2023] [Indexed: 08/09/2023]
Abstract
Recently, additive manufacturing (AM) has been investigated as an innovative method to manufacture stents due to its capability in producing complex and customized structures. In this paper, the cardiovascular stents of M-type and N-type with inverse unequal height strut structure and N-type with equal height strut structure were designed and manufactured by Selective Laser Melting (SLM). Following surface polishing, balloon expansion, plane compression and three-point bending experiments were carried out to evaluate the mechanical performance of the stent. The stents designed with inverse unequal height strut structure showed higher radial support performance and lower radial recoil when compared to the stents with uniform design. This study proved the feasibility of SLM in rapid manufacturing of cardiovascular stents that can be used for performance evaluation in design stage.
Collapse
Affiliation(s)
- Qilong Wang
- School of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan, 056038, China
| | - Suxia Huang
- School of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan, 056038, China; School of Mechanical Engineering, University of Science and Technology Beijing, Beijing, 100083, China
| | - Jingtao Miao
- School of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan, 056038, China
| | - Zhiang Chen
- School of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan, 056038, China
| | - Hezong Li
- School of Mechanical and Equipment Engineering, Hebei University of Engineering, Handan, 056038, China; Key Laboratory of Intelligent Industrial Equipment Technology of Hebei Province, Handan, 056038, China.
| | - Liguo Zhao
- School of Energy and Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, China.
| | - Jiangyong Yuan
- Affiliated Hospital of Hebei Engineering University, Handan, 056001, China
| |
Collapse
|
15
|
Wu M, Xun M, Chen Y. Adaptation of Vascular Smooth Muscle Cell to Degradable Metal Stent Implantation. ACS Biomater Sci Eng 2023. [PMID: 37364226 DOI: 10.1021/acsbiomaterials.3c00637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2023]
Abstract
Iron-, magnesium-, or zinc-based metal vessel stents support vessel expansion at the period early after implantation and degrade away after vascular reconstruction, eliminating the side effects due to the long stay of stent implants in the body and the risks of restenosis and neoatherosclerosis. However, emerging evidence has indicated that their degradation alters the vascular microenvironment and induces adaptive responses of surrounding vessel cells, especially vascular smooth muscle cells (VSMCs). VSMCs are highly flexible cells that actively alter their phenotype in response to the stenting, similarly to what they do during all stages of atherosclerosis pathology, which significantly influences stent performance. This Review discusses how biodegradable metal stents modify vascular conditions and how VSMCs respond to various chemical, biological, and physical signals attributable to stent implantation. The focus is placed on the phenotypic adaptation of VSMCs and the clinical complications, which highlight the importance of VSMC transformation in future stent design.
Collapse
Affiliation(s)
- Meichun Wu
- Hengyang Medical School, University of South China, Hengyang, Hunan 410001, China
- School of Nursing, University of South China, Hengyang, Hunan 410001, China
| | - Min Xun
- Institute of Pharmacy and Pharmacology, School of Pharmaceutical Science, University of South China, Hengyang, Hunan 410001, China
| | - Yuping Chen
- Hengyang Medical School, University of South China, Hengyang, Hunan 410001, China
- Institute of Pharmacy and Pharmacology, School of Pharmaceutical Science, University of South China, Hengyang, Hunan 410001, China
| |
Collapse
|
16
|
Liu X, Tao Y, Qi K, Chen Z, Qiu Y, Guo X. Integrated MOF-74 Coatings on Magnesium for Corrosion Control, Cytocompatibility, and Antibacterial Properties. Inorg Chem 2023. [PMID: 37338268 DOI: 10.1021/acs.inorgchem.3c01063] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/21/2023]
Abstract
Biodegradable Mg and its alloys can degrade safely in vivo without toxicity. The major bottleneck inhibiting their clinical use is the high corrosion rate, which leads to the loss of mechanical integrity prematurely and bad biocompatibility. One ideal strategy is the modification with anticorrosive and bioactive coatings. Numerous metal-organic framework (MOF) membranes show satisfactory anticorrosion performance and biocompatibility. In this study, MOF-74 membranes are prepared on an NH4TiOF3 (NTiF) layer-modified Mg matrix, fabricating integrated bilayer coatings (MOF-74/NTiF) for corrosion control, cytocompatibility, and antibacterial properties. The inner NTiF layer serves as the primary protection for the Mg matrix and a stable surface for the growth of MOF-74 membranes. The outer MOF-74 membranes further enhance corrosion protection, whose crystals and thicknesses can be adjusted for different protective effects. Owing to superhydrophilic, micro-nanostructural, and nontoxic decomposition products, MOF-74 membranes significantly promote cell adhesion and proliferation, showing excellent cytocompatibility. Utilizing the decomposition of MOF-74 to generate the products of Zn2+ and 2,5-dihydroxyterephthalic acid can effectively inhibit Escherichia coli and Staphylococcus aureus, displaying highly efficient antibacterial properties. The research may shed valuable strategies for MOF-based functional coatings in the applications of biomedicine fields.
Collapse
Affiliation(s)
- Xiaobang Liu
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan 430074, P. R. China
- Xi'an Rare Metal Materials Institute Co., Ltd., Xi'an 710016, P. R. China
| | - Yuchu Tao
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan 430074, P. R. China
| | - Kai Qi
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan 430074, P. R. China
| | - Zhenyu Chen
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan 430074, P. R. China
| | - Yubing Qiu
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan 430074, P. R. China
| | - Xingpeng Guo
- School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| |
Collapse
|
17
|
Liu W, Wang X, Feng Y. Restoring endothelial function: shedding light on cardiovascular stent development. Biomater Sci 2023. [PMID: 37161519 DOI: 10.1039/d3bm00390f] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Complete endothelialization is highly important for maintaining long-term patency and avoiding subsequent complications in implanting cardiovascular stents. It not only refers to endothelial cells (ECs) fully covering the inserted stents, but also includes the newly formed endothelium, which could exert physiological functions, such as anti-thrombosis and anti-stenosis. Clinical outcomes have indicated that endothelial dysfunction, especially the insufficiency of antithrombotic and barrier functions, is responsible for stent failure. Learning from vascular pathophysiology, endothelial dysfunction on stents is closely linked to the microenvironment of ECs. Evidence points to inflammatory responses, oxidative stress, altered hemodynamic shear stress, and impaired endothelial barrier affecting the normal growth of ECs, which are the four major causes of endothelial dysfunction. The related molecular mechanisms and efforts dedicated to improving the endothelial function are emphasized in this review. From the perspective of endothelial function, the design principles, advantages, and disadvantages behind current stents are introduced to enlighten the development of new-generation stents, aiming to offer new alternatives for restoring endothelial function.
Collapse
Affiliation(s)
- Wen Liu
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, P. R. China.
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, P. R. China
| | - Xiaoyu Wang
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, P. R. China.
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, P. R. China
| | - Yakai Feng
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, P. R. China.
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, P. R. China
- Key Laboratory of Systems Bioengineering (Ministry of Education), Tianjin University, Weijin Road 92, Tianjin 300072, P. R. China
- Frontiers Science Center for Synthetic Biology, Tianjin University, Weijin Road 92, Tianjin 300072, China
| |
Collapse
|
18
|
Moura D, Pereira AT, Ferreira HP, Barrias CC, Magalhães FD, Bergmeister H, Gonçalves IC. Poly(2-hydroxyethyl methacrylate) hydrogels containing graphene-based materials for blood-contact applications: from soft inert to strong degradable material. Acta Biomater 2023; 164:253-268. [PMID: 37121371 DOI: 10.1016/j.actbio.2023.04.031] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 04/18/2023] [Accepted: 04/21/2023] [Indexed: 05/02/2023]
Abstract
Degradable biomaterials for blood-contacting devices (BCDs) are associated with weak mechanical properties, high molecular weight of the degradation products and poor hemocompatibility. Herein, the inert and biocompatible FDA approved poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogel was turned into a degradable material by incorporation of different amounts of a hydrolytically labile crosslinking agent, pentaerythritol tetrakis(3-mercaptopropionate). In situ addition of 1wt.% of oxidized graphene-based materials (GBMs) with different lateral sizes/thicknesses (single-layer graphene oxide, and oxidized forms of few-layer graphene materials) was performed to enhance the mechanical properties of hydrogels. An ultimate tensile strength increases up to 0.2 MPa (293% higher than degradable pHEMA) was obtained using oxidized few-layer graphene with 5 μm lateral size. Moreover, the incorporation of GBMs has demonstrated to simultaneously tune the degradation time, which ranged from 2 to 4 months. Notably, these features were achieved keeping not only the intrinsic properties of inert pHEMA regarding water uptake, wettability and cytocompatibility (short and long term), but also the non-fouling behavior towards human cells, platelets and bacteria. This new pHEMA hydrogel with degradation and biomechanical performance tuned by GBMs, can therefore be envisioned for different applications in tissue engineering, particularly for BCDs where non-fouling character is essential. STATEMENT OF SIGNIFICANCE: Suitable mechanical properties, low molecular weight of the degradation products and hemocompatibility are key features in degradable blood contacting devices (BCDs), and pave the way for significant improvement in the field. In here, a hydrogel with outstanding anti-adhesiveness (pHEMA) provides hemocompatibility, the presence of a degradable crosslinker provides degradability, and incorporation of graphene oxide reestablishes its strength, allowing tuning of both degradation and mechanical properties. Notably, these hydrogels simultaneously provide suitable water uptake, wettability, cytocompatibility (short and long term), no acute inflammatory response, and non-fouling behavior towards endothelial cells, platelets and bacteria. Such results highlight the potential of these hydrogels to be envisioned for applications in tissue engineered BCDs, namely as small diameter vascular grafts.
Collapse
Affiliation(s)
- Duarte Moura
- INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal; i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal; FEUP - Faculdade de Engenharia, Departamento de Engenharia Metalúrgica e de Materiais, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Andreia T Pereira
- INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal; i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal
| | - Helena P Ferreira
- INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal; i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal; ICBAS - Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, 4050-313, Portugal
| | - Cristina C Barrias
- INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal; i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal; ICBAS - Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, 4050-313, Portugal
| | - Fernão D Magalhães
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Helga Bergmeister
- Center for Biomedical Research and Translational Surgery, Medical University of Vienna, Vienna, Austria; Ludwig Boltzmann Institute for Cardiovascular Research, Austria
| | - Inês C Gonçalves
- INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal; i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-180 Porto, Portugal.
| |
Collapse
|
19
|
Dou Z, Chen S, Wang J, Xia L, Maitz MF, Tu Q, Zhang W, Yang Z, Huang N. A "built-up" composite film with synergistic functionalities on Mg-2Zn-1Mn bioresorbable stents improves corrosion control effects and biocompatibility. Bioact Mater 2023; 25:223-238. [PMID: 36817823 PMCID: PMC9929524 DOI: 10.1016/j.bioactmat.2023.02.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 02/04/2023] [Accepted: 02/04/2023] [Indexed: 02/11/2023] Open
Abstract
Control of premature corrosion of magnesium (Mg) alloy bioresorbable stents (BRS) is frequently achieved by the addition of rare earth elements. However, limited long-term experience with these elements causes concerns for clinical application and alternative methods of corrosion control are sought after. Herein, we report a "built-up" composite film consisting of a bottom layer of MgF2 conversion coating, a sandwich layer of a poly (1, 3-trimethylene carbonate) (PTMC) and 3-aminopropyl triethoxysilane (APTES) co-spray coating (PA) and on top a layer of poly (lactic-co-glycolic acid) (PLGA) ultrasonic spray coating to decorate the rare earth element-free Mg-2Zn-1Mn (ZM21) BRS for tailoring both corrosion resistance and biological functions. The developed "built-up" composite film shows synergistic functionalities, allowing the compression and expansion of the coated ZM21 BRS on an angioplasty balloon without cracking or peeling. Of special importance is that the synergistic corrosion control effects of the "built-up" composite film allow for maintaining the mechanical integrity of stents for up to 3 months, where complete biodegradation and no foreign matter residue were observed about half a year after implantation in rabbit iliac arteries. Moreover, the functionalized ZM21 BRS accomplished re-endothelialization within one month.
Collapse
Affiliation(s)
- Zhenglong Dou
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Shuiling Chen
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Jiacheng Wang
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Li Xia
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Manfred F. Maitz
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
- Max Bergmann Center of Biomaterials Dresden, Leibniz Institute of Polymer Research Dresden, Hohe Strasse 6, 01069, Dresden, Germany
| | - Qiufen Tu
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Wentai Zhang
- Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China
| | - Zhilu Yang
- Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China
- Guangdong Provincial Key Laboratory of Cardiac Function and Microcirculation, Guangzhou, Guangdong, 510080, China
- Department of Cardiology, Third People's Hospital of Chengdu Affiliated to Southwest Jiaotong University, Chengdu, 610031, China
- Corresponding author. Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China.
| | - Nan Huang
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
- Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China
- Corresponding author. Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China.
| |
Collapse
|
20
|
Li X, Ding J. Establishment of coverage-mass equation to quantify the corrosion inhomogeneity and examination of medium effects on iron corrosion. Regen Biomater 2023; 10:rbad007. [PMID: 36817974 PMCID: PMC9933843 DOI: 10.1093/rb/rbad007] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Revised: 01/19/2023] [Accepted: 01/30/2023] [Indexed: 02/04/2023] Open
Abstract
Metal corrosion is important in the fields of biomedicine as well as construction and transportation etc. While most corrosion occurs inhomogeneously, there is so far no satisfactory parameter to characterize corrosion inhomogeneity. Herein, we employ the Poisson raindrop question to model the corrosion process and derive an equation to relate corrosion coverage and corrosion mass. The resultant equation is named coverage-mass equation, abbreviated as C-M equation. We also suggest corrosion mass at 50% coverage, termed as half-coverage mass M corro50%, as an inhomogeneity parameter to quantify corrosion inhomogeneity. The equation is confirmed and the half-coverage mass M corro50% is justified in our experiments of iron corrosion in five aqueous media, normal saline, phosphate-buffered saline, Hank's solution, deionized water and artificial seawater, where the former three ones are biomimetic and very important in studies of biomedical materials. The half-coverage mass M corro50% is proved to be more comprehensive and mathematically convergent than the traditional pitting factor. Iron corrosion is detected using visual observation, scanning electron microscopy with a build-in energy dispersive spectrometer, inductive coupled plasma emission spectrometry and electrochemical measurements. Both rates and inhomogeneity extents of iron corrosion are compared among the five aqueous media. The factors underlying the medium effects on corrosion rate and inhomogeneity are discussed and interpreted. Corrosion rates of iron in the five media differ about 7-fold, and half-coverage mass values differ about 300 000-fold. The fastest corrosion and the most significant inhomogeneity occur both in biomimetic media, but not the same one. The new equation (C-M equation) and the new quantity (half-coverage mass) are stimulating for dealing with a dynamic and stochastic process with global inhomogeneity including but not limited to metal corrosion. The findings are particularly meaningful for research and development of next-generation biodegradable materials.
Collapse
Affiliation(s)
- Xin Li
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200438, China
| | | |
Collapse
|
21
|
A Comparison of Vessel Patch Materials in Tetralogy of Fallot Patients Using Virtual Surgery Techniques. Ann Biomed Eng 2023:10.1007/s10439-023-03144-x. [PMID: 36723833 DOI: 10.1007/s10439-023-03144-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 12/25/2022] [Indexed: 02/02/2023]
Abstract
Tetralogy of Fallot (ToF) is characterized by stenosis causing partial obstruction of the right ventricular outflow tract, typically alleviated through the surgical application of a vessel patch made from a biocompatible material. In this study, we use computational simulations to compare the mechanical performance of four patch materials for various stenosis locations. Nine idealized pre-operative ToF geometries were created by imposing symmetrical stenoses on each of three anatomical sub-regions of the pulmonary arteries of three patients with previously repaired ToF. A virtual surgery methodology was implemented to replicate the steps of vessel de-pressurization, surgical patching, and subsequent vessel expansion after reperfusion. Significant differences in patch average stress (p < 0.001) were found between patch materials. Biological patch materials (porcine xenopericardium, human pericardium) exhibited higher patch stresses in comparison to synthetic patch materials (Dacron and PTFE). Observed differences were consistent across the various stenosis locations and were insensitive to patient anatomy.
Collapse
|
22
|
Cao H, Wu H, Li J, Li M, Lin C. Influence of different postballoon expansion procedures: A finite element analysis. Med Phys 2023; 50:30-37. [PMID: 36342301 DOI: 10.1002/mp.16086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 09/22/2022] [Accepted: 09/26/2022] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND Postballoon expansion is considered as an appropriate procedure for adequate stent expansion for coronary bifurcation lesions. Two postballoon expansion procedures are currently recommended: proximal optimization technique (POT)/side/POT and POT/kiss/POT. However, the effects of the two postballoon expansion treatments are different. There is a lack of biomechanical study to quantify the difference. PURPOSE It is recognized that biomechanical factors influence the occurrence of Major Cardiovascular Adverse Events (MACE), which includes recurrent angina pectoris, acute myocardial infarction and coronary heart disease death. The current paper evaluated the two postexpansion strategies and quantified biomechanical parameters to provide a basis for clinical decisions. METHODS Based on the CT angiography (CTA) data of a patient diagnosed with coronary bifurcation lesions, a personalized coronary bifurcation lesion model was constructed, and the surgical procedure after two expansions was simulated. The POT/side/POT and POT/kiss/POT expansion procedures were analyzed from the perspective of biomechanics through finite element analysis. The biomechanics factors, including the percentage of stent malapposition and stent occlusion at the side branch (SB) opening, the stent ellipse index of proximal main vessel (PMV) segment, the minimum lumen area of the stent vessel segment and the stress distribution of the vessel wall, were used to quantify clinician concerns about factors affecting patient outcomes. The factors include stent adhesion, SB open stent occlusion, poor stent deformation, patency effect of vessel stenosis, and vessel wall damage. RESULTS Both postexpansion procedures were successfully simulated. The malapposition rate during POT/side/POT was larger (1.2% vs. 0.42%) and stent occlusion at the SB opening from the cross-section perpendicular to the SB opening after the POT/side/POT procedure was 0.20%, compared with 0.00% after POT/kiss/POT. POT/kiss/POT produced a larger PMV segment stent ellipse index. Minimum lumen area after POT/side/POT was 5.6 mm2 and after POT/kiss/POT 5.9 mm2 . POT/kiss/POT produces an effect of greater vascular stress than POT/side/POT. CONCLUSION Numerical simulations provide a quantitative analysis to inform clinicians of the differences between preoperative planning and surgical procedures. Biomechanical analysis of the differences between the two postexpansion strategies found that the POT/kiss/POT procedure resulted in better stent fit, less occlusion of the SB open stent and better vascular patency but also resulted in poor stent deformation and caused greater vessel wall stress. The current study informs rationales for clinical understanding of postexpansion strategies.
Collapse
Affiliation(s)
- Hongshuai Cao
- Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Heng Wu
- The Central Hospital of Enshi Tujia and Miao Autonomous Prefecture, Enshi, China
| | - Jiasong Li
- Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Meng Li
- Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Changyan Lin
- Beijing Anzhen Hospital, Capital Medical University, Beijing, China.,Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Beijing, China
| |
Collapse
|
23
|
Singh N, Batra U, Kumar K, Ahuja N, Mahapatro A. Progress in bioactive surface coatings on biodegradable Mg alloys: A critical review towards clinical translation. Bioact Mater 2023; 19:717-757. [PMID: 35633903 PMCID: PMC9117289 DOI: 10.1016/j.bioactmat.2022.05.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 05/06/2022] [Accepted: 05/06/2022] [Indexed: 02/07/2023] Open
Abstract
Mg and its alloys evince strong candidature for biodegradable bone implants, cardiovascular stents, and wound closing devices. However, their rapid degradation rate causes premature implant failure, constraining clinical applications. Bio-functional surface coatings have emerged as the most competent strategy to fulfill the diverse clinical requirements, besides yielding effective corrosion resistance. This article reviews the progress of biodegradable and advanced surface coatings on Mg alloys investigated in recent years, aiming to build up a comprehensive knowledge framework of coating techniques, processing parameters, performance measures in terms of corrosion resistance, adhesion strength, and biocompatibility. Recently developed conversion and deposition type surface coatings are thoroughly discussed by reporting their essential therapeutic responses like osteogenesis, angiogenesis, cytocompatibility, hemocompatibility, anti-bacterial, and controlled drug release towards in-vitro and in-vivo study models. The challenges associated with metallic, ceramic and polymeric coatings along with merits and demerits of various coatings have been illustrated. The use of multilayered hybrid coating comprising a unique combination of organic and inorganic components has been emphasized with future perspectives to obtain diverse bio-functionalities in a facile single coating system for orthopedic implant applications.
Collapse
Affiliation(s)
- Navdeep Singh
- Department of Metallurgical and Materials Engineering, Punjab Engineering College, Chandigarh, 160012, India
| | - Uma Batra
- Department of Metallurgical and Materials Engineering, Punjab Engineering College, Chandigarh, 160012, India
| | - Kamal Kumar
- Department of Mechanical Engineering, Punjab Engineering College, Chandigarh, 160012, India
| | - Neeraj Ahuja
- Department of Metallurgical and Materials Engineering, Punjab Engineering College, Chandigarh, 160012, India
| | - Anil Mahapatro
- Department of Biomedical Engineering, Wichita State University, Wichita, KS, 67260, United States
| |
Collapse
|
24
|
Huang L, Fang H, Zhang T, Hu B, Liu S, Lv F, Zeng Z, Liu H, Zhou W, Wang X. Drug-loaded balloon with built-in NIR controlled tip-separable microneedles for long-effective arteriosclerosis treatment. Bioact Mater 2022; 23:526-538. [PMID: 36514389 PMCID: PMC9730155 DOI: 10.1016/j.bioactmat.2022.11.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 10/24/2022] [Accepted: 11/22/2022] [Indexed: 12/12/2022] Open
Abstract
Drug-eluting balloon (DEB) angioplasty has emerged as an effective treatment for cardiovascular and cerebrovascular diseases. However, distal embolism and late lumen restenosis could be caused by drug loss during DEB handling and rapid drug metabolization. Here, a drug-loaded balloon equipped with tip-separable microneedles on the balloon surface (MNDLB) was developed. Inbuilt near-infrared (NIR) ring laser inside the catheter inner shaft was introduced to activate the biodegradable microneedle tips for the first time. The drug-loaded tips thus could be embedded in the vasculature and then released antiproliferative drug - paclitaxel slowly via polymer degradation for more than half a year. A significant increase in drug delivery efficiency and superior therapeutic effectiveness compared with the standard DEB were demonstrated using an atherosclerosis rabbit model.
Collapse
Affiliation(s)
- Li Huang
- Department of Vascular Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi, 330006, PR China,The National Engineering Research Center for Bioengineering Drugs and the Technologies, Institute of Translational Medicine, Nanchang University, Nanchang, Jiangxi, 330088, PR China
| | - Huaqiang Fang
- Department of Vascular Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi, 330006, PR China
| | - Teng Zhang
- Department of Vascular Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi, 330006, PR China
| | - Binbin Hu
- The National Engineering Research Center for Bioengineering Drugs and the Technologies, Institute of Translational Medicine, Nanchang University, Nanchang, Jiangxi, 330088, PR China
| | - Shichen Liu
- Department of Vascular Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi, 330006, PR China
| | - Fanzhen Lv
- Department of Vascular Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi, 330006, PR China
| | - Zhaoxia Zeng
- Department of Radiology, The Second Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi, 330006, PR China
| | - Huijie Liu
- The National Engineering Research Center for Bioengineering Drugs and the Technologies, Institute of Translational Medicine, Nanchang University, Nanchang, Jiangxi, 330088, PR China
| | - Weimin Zhou
- Department of Vascular Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi, 330006, PR China,Corresponding author.
| | - Xiaolei Wang
- The National Engineering Research Center for Bioengineering Drugs and the Technologies, Institute of Translational Medicine, Nanchang University, Nanchang, Jiangxi, 330088, PR China,School of Chemistry and Chemical Engineering, Nanchang University, Nanchang, Jiangxi, 330088, PR China,Corresponding author. The National Engineering Research Center for Bioengineering Drugs and the Technologies, Institute of Translational Medicine, Nanchang University, Nanchang, Jiangxi, 330088, PR China.
| |
Collapse
|
25
|
Multi-Objective Optimization of Bioresorbable Magnesium Alloy Stent by Kriging Surrogate Model. Cardiovasc Eng Technol 2022; 13:829-839. [PMID: 35414048 DOI: 10.1007/s13239-022-00619-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 03/28/2022] [Indexed: 01/27/2023]
Abstract
PURPOSE The study proposed a multi-objective optimization method based on Kriging surrogate model and finite element analysis to mitigate the redial recoil and foreshortening ratio of bioresorbable magnesium alloy stent, and investigate the impact of strut thickness on stent expansion behavior. METHODS Finite element analysis have been carried out to compare the expansion behavior of stents with various strut thickness. Latin hypercube sampling (LHS) was adopted to generate train sample points in the design space, and the Kriging surrogate model was constructed between strut parameters and stent behavior. The genetic algorithm (GA) was employed to find the optimal solution in the global design space. RESULTS Stents with thinner struts experience lower stress but suffer from severe radial recoil and foreshortening effects. The radial recoil is decreased by 66%, and foreshortening ratio is reduced by 60% for the optimized stent with U-bend width 90.7 [Formula: see text] and link width 77.9 [Formula: see text]. The errors between Kriging surrogate model and finite element simulation are 6% and 9% for the radial recoil and foreshortening ratio. CONCLUSION Stent expansion behavior are highly dependent on design parameters, i.e. thickness, U-bend and link strut width. The purposed Multi-objective optimization approach based on Kriging surrogate model and finite element analysis is efficient in stent design optimization problem.
Collapse
|
26
|
Zong J, He Q, Liu Y, Qiu M, Wu J, Hu B. Advances in the development of biodegradable coronary stents: A translational perspective. Mater Today Bio 2022; 16:100368. [PMID: 35937578 PMCID: PMC9352968 DOI: 10.1016/j.mtbio.2022.100368] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 06/25/2022] [Accepted: 07/13/2022] [Indexed: 11/17/2022] Open
Abstract
Implantation of cardiovascular stents is an important therapeutic method to treat coronary artery diseases. Bare-metal and drug-eluting stents show promising clinical outcomes, however, their permanent presence may create complications. In recent years, numerous preclinical and clinical trials have evaluated the properties of bioresorbable stents, including polymer and magnesium-based stents. Three-dimensional (3D) printed-shape-memory polymeric materials enable the self-deployment of stents and provide a novel approach for individualized treatment. Novel bioresorbable metallic stents such as iron- and zinc-based stents have also been investigated and refined. However, the development of novel bioresorbable stents accompanied by clinical translation remains time-consuming and challenging. This review comprehensively summarizes the development of bioresorbable stents based on their preclinical/clinical trials and highlights translational research as well as novel technologies for stents (e.g., bioresorbable electronic stents integrated with biosensors). These findings are expected to inspire the design of novel stents and optimization approaches to improve the efficacy of treatments for cardiovascular diseases. Bioresorbable stents can overcome the limitations of non-degradable stents. 3D printing of shape-memory polymeric stents can lead to better clinical outcomes. Advances in Mg-, Fe- and Zn-based stents from a translational perspective. Electronic stents integrated with biosensors can covey stent status in real time. Development in the assessment of stent performance in vivo.
Collapse
Affiliation(s)
- Jiabin Zong
- Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - Quanwei He
- Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - Yuxiao Liu
- Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - Min Qiu
- Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - Jiehong Wu
- Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
- Corresponding author.
| | - Bo Hu
- Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
- Corresponding author.
| |
Collapse
|
27
|
Wang Y, Li G, Yang L, Luo R, Guo G. Development of Innovative Biomaterials and Devices for the Treatment of Cardiovascular Diseases. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2201971. [PMID: 35654586 DOI: 10.1002/adma.202201971] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 05/29/2022] [Indexed: 06/15/2023]
Abstract
Cardiovascular diseases have become the leading cause of death worldwide. The increasing burden of cardiovascular diseases has become a major public health problem and how to carry out efficient and reliable treatment of cardiovascular diseases has become an urgent global problem to be solved. Recently, implantable biomaterials and devices, especially minimally invasive interventional ones, such as vascular stents, artificial heart valves, bioprosthetic cardiac occluders, artificial graft cardiac patches, atrial shunts, and injectable hydrogels against heart failure, have become the most effective means in the treatment of cardiovascular diseases. Herein, an overview of the challenges and research frontier of innovative biomaterials and devices for the treatment of cardiovascular diseases is provided, and their future development directions are discussed.
Collapse
Affiliation(s)
- Yunbing Wang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu, 610064, China
| | - Gaocan Li
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu, 610064, China
| | - Li Yang
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu, 610064, China
| | - Rifang Luo
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu, 610064, China
| | - Gaoyang Guo
- National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, 29 Wangjiang Road, Chengdu, 610064, China
| |
Collapse
|
28
|
Huang H, Li G, Jia Q, Bian D, Guan S, Kulyasova O, Valiev RZ, Rau JV, Zheng Y. Recent advances on the mechanical behavior of zinc based biodegradable metals focusing on the strain softening phenomenon. Acta Biomater 2022; 152:1-18. [PMID: 36028200 DOI: 10.1016/j.actbio.2022.08.041] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 08/12/2022] [Accepted: 08/17/2022] [Indexed: 01/09/2023]
Abstract
Zinc based biodegradable metals (BMs) show great potential to be used in various biomedical applications, owing to their superior biodegradability and biocompatibility. Some high-strength (ultimate tensile strength > 600 MPa) Zn based BMs have already been developed through alloying and plastic working, making their use in load-bearing environments becomes a reality. However, different from Mg and Fe based BMs, Zn based BMs exhibit significant "strain-softening" effect that leads to limited uniform deformation. Non-uniform deformation is detrimental to Zn based devices or implants, which will possibly lead to unexpected failure. People might be misled by the considerable fracture elongation of Zn based BMs. Thus, it is important to specify uniform elongation as a term of mechanical requirements for Zn based BMs. In this review, recent advances on the mechanical properties of Zn based BMs have been comprehensively summarized, especially focusing on the strain softening phenomenon. At first, the origin and evaluation criteria of strain softening were introduced. Secondly, the effects of alloying elements (including element type, single or multiple addition, and alloying content) and microstructural characteristics (grain size, constituent phase, phase distribution, etc.) on mechanical properties (especially for uniform elongation) of Zn based BMs were summarized. Finally, how to get a good balance between strength and uniform elongation was generally discussed based on the service environment. In addition, possible ways to minimize or eliminate the strain softening effect were also proposed, such as controlling of twins, solute clusters, and grain boundary characteristics. All these items above would be helpful to understand the mechanical instability of Zn based BMs, and to make the full usage of them in the future medical device design. STATEMENT OF SIGNIFICANCE: Biodegradable metals (BMs) is a hotspot in the field of metallic biomaterials. Fracture elongation is normally adopted to quantify the deformability of Mg and Fe based BMs owing to their negligible necking strain, yet the strain softening would occur in Zn based BMs, which is extremely detrimental to performance of their medical device. In this review paper, a better understanding the mechanical performance of Zn-based BMs with the term "uniform elongation" instead of "fracture elongation" was depicted, and possible ways to minimize or eliminate the strain softening effect were also proposed, such as twins, solute clusters, self-stable dislocation network, and grain boundary characteristics. It would be helpful to understand the mechanical instability of Zn based BMs and making full usage of it in the future medical device design.
Collapse
Affiliation(s)
- He Huang
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450003, China
| | - Guannan Li
- School of Materials Science and Engineering, Peking University, Beijing, 100871, China
| | - Qinggong Jia
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450003, China
| | - Dong Bian
- Medical Research Center, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China.
| | - Shaokang Guan
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450003, China
| | - Olga Kulyasova
- Institute of Physics of Advanced Materials, Ufa State Aviation Technical University, 12 K. Marx St., Ufa, 450008, Russia
| | - R Z Valiev
- Institute of Physics of Advanced Materials, Ufa State Aviation Technical University, 12 K. Marx St., Ufa, 450008, Russia
| | - Julietta V Rau
- Istituto di Struttura della Materia, Consiglio Nazionale delle Ricerche (ISM-CNR), Via del Fosso del Cavaliere, 100-00133, Rome, Italy; Sechenov First Moscow State Medical University, Institute of Pharmacy, Department of Analytical, Physical and Colloid Chemistry, Trubetskaya 8, build. 2, 119991 Moscow, Russia
| | - Yufeng Zheng
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450003, China; School of Materials Science and Engineering, Peking University, Beijing, 100871, China.
| |
Collapse
|
29
|
Sreenivasamurthy SA, Akhter FF, Akhter A, Su Y, Zhu D. Cellular mechanisms of biodegradable zinc and magnesium materials on promoting angiogenesis. BIOMATERIALS ADVANCES 2022; 139:213023. [PMID: 35882117 DOI: 10.1016/j.bioadv.2022.213023] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 06/15/2022] [Accepted: 07/05/2022] [Indexed: 06/15/2023]
Abstract
Biodegradable metals, zinc and magnesium, have been regarded as next-generation, biomedical implant materials to promote tissue repair and regeneration. These implants might also promote the vascularization of surrounding neotissue. Released metallic ions, Zn2+ and Mg2+, show promise in vitro to implement vessel growth by stimulating the expression of pro-angiogenic cytokines, yet there is little known regarding how cellular responses transcend to influence the tissue environment. This study serves to optimize angiogenic behavior using EA.hy926 endothelial cultures exposed to Zn2+ and Mg2+ gradients and observe the translation of these effects on blood vessel development via the in ovo chorioallantoic membrane (CAM) assay. Findings indicate that Zn2+ 10 μM and Mg2+ 10 mM instigate the most prominent effects using endothelial cultures via scratch wound and tube formation assays, yet higher concentrations at Zn2+ 50 μM and Mg2+ 50 mM encourage significant angiogenesis along the CAM. Immunoblotting results also conclude the presence and upregulation of cytokines involved in vessel growth. Optimizing the angiogenic potential of Zn2+ and Mg2+ separately sheds light to design future engineering constructs for promoting blood vessel development and successful assimilation between host and implant tissue.
Collapse
Affiliation(s)
- Sai A Sreenivasamurthy
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States
| | - Fnu Firoz Akhter
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States
| | - Asma Akhter
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States
| | - Yingchao Su
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States
| | - Donghui Zhu
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States.
| |
Collapse
|
30
|
Fabrication and characterization of biodegradable Zn-Cu-Mn alloy micro-tubes and vascular stents: microstructure, texture, mechanical properties and corrosion behavior. Acta Biomater 2022; 151:647-660. [DOI: 10.1016/j.actbio.2022.07.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 07/21/2022] [Accepted: 07/26/2022] [Indexed: 11/20/2022]
|
31
|
Biodegradable PTX-PLGA-coated magnesium stent for benign esophageal stricture: An experimental study. Acta Biomater 2022; 146:495-505. [PMID: 35487426 DOI: 10.1016/j.actbio.2022.04.038] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 04/20/2022] [Accepted: 04/21/2022] [Indexed: 01/21/2023]
Abstract
Biodegradable stents can degrade step by step and thereby avoid secondary removal by endoscopic procedures in contrast to metal stents. Herein, a biodegradable composite stent, a magnesium (Mg)-based braided stent with a surface coating of poly (lactic-co-glycolic acid) (PLGA) containing paclitaxel (PTX), was designed and tested. By adding this drug-loaded polymer coating, the radial force of the stent increased from 33 Newton (N) to 83 N. PTX was continuously released as the stent degraded, and the in vitro cumulative drug release in phosphate-buffered saline for 28 days was 115 ± 13.5 μg/mL at pH = 7.4 and 176 ± 12 μg/mL at pH = 4.0. There was no statistically significant difference in the viability of fibroblasts of stent extracts with different concentration gradients (P > 0.05), while the PTX-loaded stents effectively promoted fibroblast apoptosis. In the animal experiment, the stents were able to maintain esophageal patency during the 3-week follow-up and to reduce the infiltration of inflammatory cells and the amount of fibrous tissue. These results showed that the PTX-PLGA-coated Mg stent has the potential to be a safe and effective approach for benign esophageal stricture. STATEMENT OF SIGNIFICANCE: We designed a biodegradable composite stent, having poly (lactic-co-glycolic acid) (PLGA) containing paclitaxel (PTX) coated the surface of the magnesium (Mg)-based braided stent. We evaluated in vitro and in vivo characteristics of the Mg esophageal stent having a PLGA coating plus a variable concentration of PTX in comparison with the absence of PTX PLGA coating. The PTX PLGA stents exerted higher radial force than stents without coating, degraded more quickly in an acid medium, and effectively promoted fibroblast apoptosis in vitro experiments. In a rabbit model of caustic-induced esophageal stricture, there was an increased lumen and decreased inflammation of the esophageal wall in the animals stented with PTX-PLGA versus the sham group, indicating a potential approach for benign esophageal stricture.
Collapse
|
32
|
Suljevic O, Fischerauer SF, Weinberg AM, Sommer NG. Immunological reaction to magnesium-based implants for orthopedic applications. What do we know so far? A systematic review on in vivo studies. Mater Today Bio 2022; 15:100315. [PMID: 35757033 PMCID: PMC9214802 DOI: 10.1016/j.mtbio.2022.100315] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Revised: 05/15/2022] [Accepted: 06/02/2022] [Indexed: 12/09/2022] Open
Abstract
Magnesium-based implants (Mg) became an attractive candidate in orthopedic surgery due to their valuable properties, such as osteoconductivity, biodegradability, elasticity and mechanical strength. However, previous studies on biodegradable and non-biodegradable metal implants showed that these materials are not inert when placed in vivo as they interact with host defensive mechanisms. The aim of this study was to systematically review available in vivo studies with Mg-based implants that investigated immunological reactions to these implants. The following questions were raised: Do different types of Mg-based implants in terms of shape, size and alloying system cause different extent of immune response? and; Are there missing links to properly understand immunological reactions upon implantation and degradation of Mg-based implants? The database used for the literature research was PubMed (U.S. National Library of Medicine) and it was undertaken in the end of 2021. The inclusion criteria comprised (i) in vivo studies with bony implantation of Mg-based implants and (ii) analysis of the presence of local immune cells or systemic inflammatory parameters. We further excluded any studies involving coated Mg-implants, in vitro studies, and studies in which the implants had no bone contact. The systematic search process was conducted according to PRISMA guidelines. Initially, the search yielded 225 original articles. After reading each article, and based on the inclusion and exclusion criteria, 16 articles were included in the systematic review. In the available studies, Mg-based implants were not found to cause any severe inflammatory reaction, and only a mild to moderate inflammatory potential was attributed to the material. The timeline of foreign body giant cell formation showed to be different between the reviewed studies. The variety of degradation kinetics of different tested implants and discrepancies in studies regarding the time points of immunological investigations impair the conclusion of immunological reactions. This may be induced by different physical properties of an implant such as size, shape and alloying system. Further research is essential to elucidate the underlying mechanisms by which implant degradation affects the immune system. Also, better understanding will facilitate the decision of patients whether to undergo surgery with new device implantation.
Collapse
Affiliation(s)
- Omer Suljevic
- Department of Orthopedics and Traumatology, Medical University of Graz, Graz, Austria
| | - Stefan F. Fischerauer
- Department of Orthopedics and Traumatology, Medical University of Graz, Graz, Austria
| | - Annelie M. Weinberg
- Department of Orthopedics and Traumatology, Medical University of Graz, Graz, Austria
| | - Nicole G. Sommer
- Department of Orthopedics and Traumatology, Medical University of Graz, Graz, Austria
| |
Collapse
|
33
|
Zhang B, Qin Y, Yang L, Wu Y, Chen N, Li M, Li Y, Wan H, Fu D, Luo R, Yuan L, Wang Y. A Polyphenol-Network-Mediated Coating Modulates Inflammation and Vascular Healing on Vascular Stents. ACS NANO 2022; 16:6585-6597. [PMID: 35301848 DOI: 10.1021/acsnano.2c00642] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Localized drug delivery from drug-eluting stents (DESs) to target sites provides therapeutic efficacy with minimal systemic toxicity. However, DESs failure may cause thrombosis, delay arterial healing, and impede re-endothelialization. Bivalirudin (BVLD) and nitric oxide (NO) promote arterial healing. Nevertheless, it is difficult to combine hydrophilic signal molecules with hydrophobic antiproliferative drugs while maintaining their bioactivity. Here, we fabricated a micro- to nanoscale network assembly consisting of copper ion and epigallocatechin gallate (EGCG) via π-π interactions, metal coordination, and oxidative polymerization. The network incorporated rapamycin and immobilized BVLD by the thiol-ene "click" reaction and provided sustained rapamycin and NO release. Unlike rapamycin-eluting stents, those coated with the EGCG-Cu-rapamycin-BVLD complex favored competitive endothelial cell (EC) growth over that of smooth muscle cells, exhibited long-term antithrombotic efficacy, and attenuated the negative impact of rapamycin on the EC. In vivo stent implantation demonstrated that the coating promoted endothelial regeneration and hindered restenosis. Therefore, the polyphenol-network-mediated surface chemistry can be an effective strategy for the engineering of multifunctional surfaces.
Collapse
Affiliation(s)
- Bo Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Yumei Qin
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Li Yang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Ye Wu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Nuoya Chen
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Mingyu Li
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Yanyan Li
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Huining Wan
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Daihua Fu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Rifang Luo
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Lu Yuan
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, 610065, China
| |
Collapse
|
34
|
Li Y, Wang Y, Shen Z, Miao F, Wang J, Sun Y, Zhu S, Zheng Y, Guan S. A biodegradable magnesium alloy vascular stent structure: Design, optimisation and evaluation. Acta Biomater 2022; 142:402-412. [PMID: 35085798 DOI: 10.1016/j.actbio.2022.01.045] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 01/05/2022] [Accepted: 01/18/2022] [Indexed: 02/07/2023]
Abstract
The existing biodegradable magnesium alloy stent (BMgS) structure is prone to problems, such as insufficient support capacity and early fracture at areas of concentrated stress. Herein, a stent structural design, which reduced the cross section of the traditional sin-wave stent by nearly 30% and introduces a regular arc structure in the middle of the support ring. The influence of the dual-parameter design of bending radius (r) and ring length (L) on plastic deformation, expansion and compression resistance performances are discussed. The non-dominated sorting genetic algorithm II (NSGA-II) was used to search for the optimal solution. It was found that the introduction of parameter r effectively improved the plastic deformation and expansion performance, and the reduction of L improved stent compression resistance. Finally, an optimized stent configuration was obtained. In vitro mechanical tests, including balloon inflation, radial strength and flexibility, verified the simulation results. The radial strength for the optimised stent increases by approximately 40% compared with that for the sinusoidal stent. Microarea X-ray diffraction result shows that the circumferential residual stress for the optimised stent decreases by half compared with that for the sinusoidal stent, thus effectively reducing the stress concentration phenomenon. STATEMENT OF SIGNIFICANCE: Despite current progress in BMgS research, the optimal design of the structure is limited. We present a new type of structurally designed stent. The performance of this stent was analysed by a finite element method and experimentally verified. The structural design positively influenced stent performance.
Collapse
Affiliation(s)
- Yafei Li
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China
| | - Yan Wang
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China
| | - Zhenquan Shen
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Fulong Miao
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China
| | - Jianfeng Wang
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Advanced Materials Processing & Mold Ministry of Education, Zhengzhou 450002, China
| | - Yufeng Sun
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Advanced Materials Processing & Mold Ministry of Education, Zhengzhou 450002, China
| | - Shijie Zhu
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Advanced Materials Processing & Mold Ministry of Education, Zhengzhou 450002, China
| | - Yufeng Zheng
- School of Materials Science and Engineering, College of Engineering, Peking University, Beijing 100871, China
| | - Shaokang Guan
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Advanced Materials Processing & Mold Ministry of Education, Zhengzhou 450002, China.
| |
Collapse
|
35
|
Selvakumar PP, Rafuse MS, Johnson R, Tan W. Applying Principles of Regenerative Medicine to Vascular Stent Development. Front Bioeng Biotechnol 2022; 10:826807. [PMID: 35321023 PMCID: PMC8936177 DOI: 10.3389/fbioe.2022.826807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 01/17/2022] [Indexed: 11/16/2022] Open
Abstract
Stents are a widely-used device to treat a variety of cardiovascular diseases. The purpose of this review is to explore the application of regenerative medicine principles into current and future stent designs. This review will cover regeneration-relevant approaches emerging in the current research landscape of stent technology. Regenerative stent technologies include surface engineering of stents with cell secretomes, cell-capture coatings, mimics of endothelial products, surface topography, endothelial growth factors or cell-adhesive peptides, as well as design of bioresorable materials for temporary stent support. These technologies are comparatively analyzed in terms of their regenerative effects, therapeutic effects and challenges faced; their benefits and risks are weighed up for suggestions about future stent developments. This review highlights two unique regenerative features of stent technologies: selective regeneration, which is to selectively grow endothelial cells on a stent but inhibit the proliferation and migration of smooth muscle cells, and stent-assisted regeneration of ischemic tissue injury.
Collapse
Affiliation(s)
| | | | | | - Wei Tan
- University of Colorado Boulder, Boulder, CO, United States
| |
Collapse
|
36
|
Amukarimi S, Mozafari M. Biodegradable Magnesium Biomaterials-Road to the Clinic. Bioengineering (Basel) 2022; 9:107. [PMID: 35324796 PMCID: PMC8945684 DOI: 10.3390/bioengineering9030107] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 02/24/2022] [Indexed: 01/09/2023] Open
Abstract
In recent decades, we have witnessed radical changes in the use of permanent biomaterials. The intrinsic ability of magnesium (Mg) and its alloys to degrade without releasing toxic degradation products has led to a vast range of applications in the biomedical field, including cardiovascular stents, musculoskeletal, and orthopedic applications. With the use of biodegradable Mg biomaterials, patients would not suffer second surgery and surgical pain anymore. Be that as it may, the main drawbacks of these biomaterials are the high corrosion rate and unexpected degradation in physiological environments. Since biodegradable Mg-based implants are expected to show controllable degradation and match the requirements of specific applications, various techniques, such as designing a magnesium alloy and modifying the surface characteristics, are employed to tailor the degradation rate. In this paper, some fundamentals and particular aspects of magnesium degradation in physiological environments are summarized, and approaches to control the degradation behavior of Mg-based biomaterials are presented.
Collapse
|
37
|
Jiang J, Qian Y, Huang H, Niu J, Yuan G. Biodegradable Zn-Cu-Mn alloy with suitable mechanical performance and in vitro degradation behavior as a promising candidate for vascular stents. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2022; 133:112652. [PMID: 35034818 DOI: 10.1016/j.msec.2022.112652] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/15/2021] [Accepted: 01/04/2022] [Indexed: 10/19/2022]
Abstract
Recently, zinc (Zn) alloy has been considered as a promising biodegradable material due to its excellent physiological degradable behavior and acceptable biocompatibility. However, poor mechanical performance limits its application as vascular stents. In this study, novel biodegradable Zn-2.2Cu-xMn (x = 0.4, 0.7, and 1.0 wt%) alloys with suitable mechanical performance were investigated. The effects of Mn addition on microstructure, mechanical properties, and in vitro degradation of Zn-2.2Cu-xMn alloys were systematically investigated. After adding Mn, dynamic recrystallization (DRX) during hot extrusion was promoted, resulting in slightly finer grain size, higher DRXed regions ratio, and weaker texture. And volume fraction and number density of second phase precipitates (micron, submicron, and nano-sized ε and MnZn13 phase) and the concentration of (Cu, Mn) in the matrix were increased. Therefore, Zn-2.2Cu-xMn alloys exhibited suitable mechanical performances (strength >310 MPa, elongation >30%) mainly due to the combination effects of grain refinement, solid solution strengthening, second phase precipitation hardening, and texture weakening. Moreover, the alloys maintained good stability of mechanical properties within 18 months and good elongation over 15% even at a high strain rate of 0.1 s-1. In addition, the alloys presented appropriate in vitro degradation rates in a basically uniform degradation mode and acceptable in vitro cytocompatibility. The above results indicated that the newly designed biodegradable Zn-2.2Cu-0.4Mn alloy with suitable comprehensive mechanical properties, appropriate degradation behavior, and acceptable cytocompatibility is a promising candidate for vascular stents.
Collapse
Affiliation(s)
- Jimiao Jiang
- National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yi Qian
- National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, Shanghai Jiao Tong University, Shanghai 200240, China; Department of Vascular and Cardiology, Ruijin Hospital, Shanghai Jiao Tong University, Shanghai 200025, China
| | - Hua Huang
- National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, Shanghai Jiao Tong University, Shanghai 200240, China.
| | - Jialin Niu
- National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Guangyin Yuan
- National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, Shanghai Jiao Tong University, Shanghai 200240, China.
| |
Collapse
|
38
|
Yuan W, Xia D, Wu S, Zheng Y, Guan Z, Rau JV. A review on current research status of the surface modification of Zn-based biodegradable metals. Bioact Mater 2022; 7:192-216. [PMID: 34466727 PMCID: PMC8379348 DOI: 10.1016/j.bioactmat.2021.05.018] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 05/09/2021] [Accepted: 05/09/2021] [Indexed: 12/13/2022] Open
Abstract
Recently, zinc and its alloys have been proposed as promising candidates for biodegradable metals (BMs), owning to their preferable corrosion behavior and acceptable biocompatibility in cardiovascular, bone and gastrointestinal environments, together with Mg-based and Fe-based BMs. However, there is the desire for surface treatment for Zn-based BMs to better control their biodegradation behavior. Firstly, the implantation of some Zn-based BMs in cardiovascular environment exhibited intimal activation with mild inflammation. Secondly, for orthopedic applications, the biodegradation rates of Zn-based BMs are relatively slow, resulting in a long-term retention after fulfilling their mission. Meanwhile, excessive Zn2+ release during degradation will cause in vitro cytotoxicity and in vivo delayed osseointegration. In this review, we firstly summarized the current surface modification methods of Zn-based alloys for the industrial applications. Then we comprehensively summarized the recent progress of biomedical bulk Zn-based BMs as well as the corresponding surface modification strategies. Last but not least, the future perspectives towards the design of surface bio-functionalized coatings on Zn-based BMs for orthopedic and cardiovascular applications were also briefly proposed.
Collapse
Affiliation(s)
- Wei Yuan
- School of Materials Science and Engineering, Peking University, Beijing, 100871, China
| | - Dandan Xia
- School of Materials Science and Engineering, Peking University, Beijing, 100871, China
- National Engineering Laboratory for Digital and Material Technology of Stomatology, National Clinical Research Center for Oral Diseases, Beijing Key Laboratory of Digital Stomatology, National Medical Products Administration Key Laboratory for Dental Materials, Research Center of Engineering and Technology for Digital Dentistry, Ministry of Health, Beijing, 100081, China
| | - Shuilin Wu
- School of Materials Science & Engineering, The Key Laboratory of Advanced Ceramics and Machining Technology by the Ministry of Education of China, Tianjin University, Tianjin, 300072, China
| | - Yufeng Zheng
- School of Materials Science and Engineering, Peking University, Beijing, 100871, China
- National Engineering Laboratory for Digital and Material Technology of Stomatology, National Clinical Research Center for Oral Diseases, Beijing Key Laboratory of Digital Stomatology, National Medical Products Administration Key Laboratory for Dental Materials, Research Center of Engineering and Technology for Digital Dentistry, Ministry of Health, Beijing, 100081, China
| | - Zhenpeng Guan
- Orthopedics Department, Peking University Shougang Hospital, No. 9 Jinyuanzhuang Rd, Shijingshan District, Beijing, 100144, China
| | - Julietta V. Rau
- Istituto di Struttura della Materia, Consiglio Nazionale delle Ricerche (ISM-CNR), Via del Fosso del Cavaliere, 100-00133, Rome, Italy
- Sechenov First Moscow State Medical University, Institute of Pharmacy, Department of Analytical, Physical and Colloid Chemistry, Trubetskaya 8, build. 2, 119991, Moscow, Russia
| |
Collapse
|
39
|
Wang Y, Huang H, Jia G, Zeng H, Yuan G. Fatigue and dynamic biodegradation behavior of additively manufactured Mg scaffolds. Acta Biomater 2021; 135:705-722. [PMID: 34469790 DOI: 10.1016/j.actbio.2021.08.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 08/22/2021] [Accepted: 08/25/2021] [Indexed: 12/16/2022]
Abstract
Additive manufacturing (AM) has enabled the fabrication of biodegradable porous metals to satisfy the desired characteristics for orthopedic applications. The geometrical design on AM biodegradable metallic scaffolds has been found to offer a favorable opportunity to regulate their mechanical and degradation performance in previous studies, however mostly confined to static responses. In this study, we presented the effect of the geometrical design on the dynamic responses of AM Mg scaffolds for the first time. Three different types of porous structures, based on various unit cells (i.e., biomimetic, diamond, and sheet-based gyroid), were established and then subjected to selective laser melting (SLM) process using group-developed Mg-Nd-Zn-Zr alloy (JDBM) powders. The topology after dynamic electropolishing, dynamic compressive properties, and dynamic biodegradation behavior of the AM Mg scaffolds were comprehensively evaluated. It was found that dynamic electropolishing effectively removed the excessive adhered powders on the surfaces and resulted in similar geometrical deviations amongst the AM Mg scaffolds, independent of their porous structures. The geometrical design significantly affected the compressive fatigue properties of the AM Mg scaffolds, of which the sheeted-based gyroid structure demonstrated a superior fatigue endurance limit of 0.85 at 106 cycles. Furthermore, in vitro dynamic immersion behaviors of the AM Mg scaffolds revealed a decent dependence on local architectures, where the sheeted-based gyroid scaffold experienced the lowest structural loss with a relatively uniform degradation mode. The obtained results indicate that the geometrical design could provide a promising strategy to develop desirable bone substitutes for the treatment of critical-size load-bearing defects. STATEMENT OF SIGNIFICANCE: Additive manufacturing (AM) has provided unprecedented opportunities to fabricate geometrically complex biodegradable scaffolds where the topological design becomes a key determinant on comprehensive performance. In this paper, we fabricate 3 AM biodegradable Mg scaffolds (i.e., biomimetic, diamond, and sheet-based gyroid) and report the effect of the geometrical design on the dynamic responses of AM Mg scaffolds for the first time. The results revealed that the sheeted-based gyroid scaffold exhibited the best combination of superior compressive fatigue properties and relatively uniform dynamic biodegradation mode, suggesting that the regulation of the porous structures could be an effective approach for the optimization of AM Mg scaffolds as to satisfy clinical requirements in orthopedic applications.
Collapse
Affiliation(s)
- Yinchuan Wang
- National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Hua Huang
- National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Gaozhi Jia
- National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China; National & Local Joint Engineering Research Center of Orthopaedic Biomaterials, Department of Bone & Joint Surgery, Peking University Shenzhen Hospital, Shenzhen 518036, China
| | - Hui Zeng
- National & Local Joint Engineering Research Center of Orthopaedic Biomaterials, Department of Bone & Joint Surgery, Peking University Shenzhen Hospital, Shenzhen 518036, China.
| | - Guangyin Yuan
- National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| |
Collapse
|
40
|
Russ JB, Li RL, Herschman AR, Waisman H, Vedula V, Kysar JW, Kalfa D. Design optimization of a cardiovascular stent with application to a balloon expandable prosthetic heart valve. MATERIALS & DESIGN 2021; 209:109977. [PMID: 34366534 PMCID: PMC8336925 DOI: 10.1016/j.matdes.2021.109977] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
A cardiovascular stent design optimization method is proposed with application to a pediatric balloon-expandable prosthetic heart valve. The prosthetic valved conduit may be expanded to a larger permanent diameter in vivo via subsequent transcatheter balloon dilation procedures. While multiple expandable prosthetic heart valves are currently at different stages of development, this work is focused on one particular design in which a stent is situated inside of an expandable polymeric valved conduit. Since the valve and conduit must be joined with a robust manufacturing technique, a polymeric glue layer is inserted between the two, which results in radial retraction of the valved region after expansion. Design of an appropriate stent is proposed to counteract this phenomenon and maintain the desired permanent diameter throughout the device after a single non-compliant balloon dilation procedure. The finite element method is used to compute performance metrics related to the permanent expansion diameter and required radial force. Additionally, failure due not only to high cycle fatigue but also due to ductile fracture is incorporated into the design study through the use of an existing ductile fracture criterion for metals. Surrogate models are constructed with the results of the high fidelity simulations and are subsequently used to numerically obtain a set of Pareto-optimal stent designs. Finally, a single design is identified by optimizing a normalized aggregate objective function with equal weighting of all design objectives.
Collapse
Affiliation(s)
- Jonathan B. Russ
- Columbia University, Department of Civil Engineering and Engineering Mechanics, New York, NY, USA
| | - Richard L. Li
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, New York, NY, USA
| | - Abigail R. Herschman
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, New York, NY, USA
| | - Haim Waisman
- Columbia University, Department of Civil Engineering and Engineering Mechanics, New York, NY, USA
| | - Vijay Vedula
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
| | - Jeffrey W. Kysar
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
- Department of Otolaryngology Head and Neck Surgery, Columbia University Medical Center, New York, NY, USA
| | - David Kalfa
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, New York, NY, USA
| |
Collapse
|
41
|
Niu J, Huang H, Pei J, Jin Z, Guan S, Yuan G. Research and development strategy for biodegradable magnesium-based vascular stents: a review. BIOMATERIALS TRANSLATIONAL 2021; 2:236-247. [PMID: 35836652 PMCID: PMC9255809 DOI: 10.12336/biomatertransl.2021.03.06] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 08/25/2021] [Accepted: 09/10/2021] [Indexed: 11/12/2022]
Abstract
Magnesium alloys are an ideal material for biodegradable vascular stents, which can be completely absorbed in the human body, and have good biosafety and mechanical properties. However, the rapid corrosion rate and excessive localized corrosion, as well as challenges in the preparation and processing of microtubes for stents, are restricting the clinical application of magnesium-based vascular stents. In the present work we will give an overview of the recent progresses on biodegradable magnesium based vascular stents including magnesium alloy design, high-precision microtubes processing, stent shape optimisation and functional coating preparation. In particular, the Triune Principle in biodegradable magnesium alloy design is proposed based on our research experience, which requires three key aspects to be considered when designing new biodegradable magnesium alloys for vascular stents application, i.e. biocompatibility and biosafety, mechanical properties, and biodegradation. This review hopes to inspire the future studies on the design and development of biodegradable magnesium alloy-based vascular stents.
Collapse
Affiliation(s)
- Jialin Niu
- National Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Hua Huang
- National Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jia Pei
- National Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhaohui Jin
- National Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Shaokang Guan
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, Henan Province, China
| | - Guangyin Yuan
- National Engineering Research Center of Light Alloy Net Forming and Key State Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China,Corresponding author: Guangyin Yuan,
| |
Collapse
|
42
|
Shi W, Li H, Mitchell K, Zhang C, Zhu T, Jin Y, Zhao D. A multi-dimensional non-uniform corrosion model for bioabsorbable metallic vascular stents. Acta Biomater 2021; 131:572-580. [PMID: 34265472 DOI: 10.1016/j.actbio.2021.07.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 06/30/2021] [Accepted: 07/02/2021] [Indexed: 12/17/2022]
Abstract
Bioabsorbable metallic vascular stents (BMVSs) are an innovative technological advancement in the medical engineering field of vascular implants. BMVSs have great potential to revolutionize vascular intervention, but the lack of understanding of the construction material's natural corrosion within the body inhibits the use in clinical medicine. In this study, a corrosion function concept for in vivo implants was created to develop a multi-dimensional, non-uniform corrosion model with a larger goal of simulating the mechanical integrity of BMVSs. This proposed corrosion model simulates the corrosion rate and its effects on magnesium (Mg) alloy AZ31 based on continuum damage mechanics. The model was calibrated using three degradation experiments on Mg alloy specimens. These experiments focused on multi-dimensional corrosion, mass loss rate, and mechanical integrity during the corrosion process. Lastly, to verify the applicability of the proposed model, the resulting corrosion behaviors and mechanical characteristics of the BMVSs were implemented into a finite element framework to produce an overarching simulation of the BMVS's degradation in vivo. The results of the experiments and simulations revealed a proportional link between the corrosion of BMVSs and the number of exposed surfaces. A non-linear decline in mechanical integrity with increasing mass loss was also discovered through experimentation and modeling. Furthermore, the model and simulation can provide some details about changes in morphology and mechanics during BMVS corrosion. This work gives new insights into accurately modeling for BMVS degradation and can be used to optimize product development of BMVSs. STATEMENT OF SIGNIFICANCE: Bioabsorbable metallic vascular stents (BMVSs) are an innovative technological advancement in the medical engineering field of vascular implants. Despite BMVSs have great potential to revolutionize vascular intervention, the lack of understanding of the construction material's natural corrosion within the body inhibits their use in clinical medicine. In this study, a novel multi-dimensional non-uniform corrosion model was proposed to unveil the mechanisms during the in vivo degradation of bioabsorbable metallic implants, which can accurately capture the overlooked changes in morphology and mechanics during BMVS corrosion. This work provides a technical solution to enhance the modeling accuracy in BMVS degradation and can be further used to optimize the design of BMVSs in the future.
Collapse
Affiliation(s)
- Weiliang Shi
- Key Laboratory for Precision & Non-traditional Machining Technology of Ministry of Education, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116024, China
| | - Hongxia Li
- Key Laboratory for Precision & Non-traditional Machining Technology of Ministry of Education, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116024, China
| | - Kellen Mitchell
- Department of Mechanical Engineering, University of Nevada Reno, Reno, NV 89557, USA
| | - Cheng Zhang
- Key Laboratory for Precision & Non-traditional Machining Technology of Ministry of Education, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116024, China
| | - Tingzhun Zhu
- Department of Neurosurgery, General Hospital of Northern Theater Command, Shenyang 110016, China
| | - Yifei Jin
- Department of Mechanical Engineering, University of Nevada Reno, Reno, NV 89557, USA.
| | - Danyang Zhao
- Key Laboratory for Precision & Non-traditional Machining Technology of Ministry of Education, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116024, China.
| |
Collapse
|
43
|
Ryu H, Seo M, Rogers JA. Bioresorbable Metals for Biomedical Applications: From Mechanical Components to Electronic Devices. Adv Healthc Mater 2021; 10:e2002236. [PMID: 33586341 DOI: 10.1002/adhm.202002236] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 01/29/2021] [Indexed: 01/16/2023]
Abstract
Bioresorbable metals and metal alloys are of growing interest for myriad uses in temporary biomedical implants. Examples range from structural elements as stents, screws, and scaffolds to electronic components as sensors, electrical stimulators, and programmable fluidics. The associated physical forms span mechanically machined bulk parts to lithographically patterned conductive traces, across a diversity of metals and alloys based on magnesium, zinc, iron, tungsten, and others. The result is a rich set of opportunities in healthcare materials science and engineering. This review article summarizes recent advances in this area, starting with an historical perspective followed by a discussion of materials options, considerations in biocompatibility, and device applications. Highlights are in system level bioresorbable electronic platforms that support functions as diagnostics and therapeutics in the context of specific, temporary clinical needs. A concluding section highlights challenges and emerging research directions.
Collapse
Affiliation(s)
- Hanjun Ryu
- Center for Bio‐Integrated Electronics Querrey Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
| | - Min‐Ho Seo
- School of Biomedical Convergence Engineering College of Information & Biomedical Engineering Pusan National University 49 Busandaehak‐ro Yangsan‐si Gyeongsangnam‐do 50612 Republic of Korea
| | - John A. Rogers
- Center for Bio‐Integrated Electronics Querrey Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
- Department of Mechanical Engineering Northwestern University Evanston IL 60208 USA
- Department of Civil and Environmental Engineering Northwestern University Evanston IL 60208 USA
- Department of Materials Science and Engineering Northwestern University Evanston IL 60208 USA
- Department of Biomedical Engineering Northwestern University Evanston IL 60208 USA
| |
Collapse
|
44
|
He J, Lin Z, Hu X, Xing L, Liang G, Chen D, An J, Xiong C, Zhang X, Zhang L. Biocompatible and biodegradable scaffold based on polytrimethylene carbonate-tricalcium phosphate microspheres for tissue engineering. Colloids Surf B Biointerfaces 2021; 204:111808. [DOI: 10.1016/j.colsurfb.2021.111808] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 04/14/2021] [Accepted: 04/27/2021] [Indexed: 12/13/2022]
|
45
|
Wu W, Khan B, Sharzehee M, Zhao S, Samant S, Watanabe Y, Murasato Y, Mickley T, Bicek A, Bliss R, Valenzuela T, Iaizzo PA, Makadia J, Panagopoulos A, Burzotta F, Samady H, Brilakis ES, Dangas GD, Louvard Y, Stankovic G, Dubini G, Migliavacca F, Kassab GS, Edelman ER, Chiastra C, Chatzizisis YS. Three dimensional reconstruction of coronary artery stents from optical coherence tomography: experimental validation and clinical feasibility. Sci Rep 2021; 11:12252. [PMID: 34112841 PMCID: PMC8192920 DOI: 10.1038/s41598-021-91458-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 05/26/2021] [Indexed: 01/09/2023] Open
Abstract
The structural morphology of coronary stents (e.g. stent expansion, lumen scaffolding, strut apposition, tissue protrusion, side branch jailing, strut fracture), and the local hemodynamic environment after stent deployment are key determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to enable the geometrically accurate three-dimensional (3D) reconstruction of coronary stents. The aim of this work was to present a novel algorithm for 3D stent reconstruction of coronary artery stents based on optical coherence tomography (OCT) and angiography, and test experimentally its accuracy, reproducibility, clinical feasibility, and ability to perform computational fluid dynamics (CFD) studies. Our method has the following steps: 3D lumen reconstruction based on OCT and angiography, stent strut segmentation in OCT images, packaging, rotation and straightening of the segmented struts, planar unrolling of the segmented struts, planar stent wireframe reconstruction, rolling back of the planar stent wireframe to the 3D reconstructed lumen, and final stent volume reconstruction. We tested the accuracy and reproducibility of our method in stented patient-specific silicone models using micro-computed tomography (μCT) and stereoscopy as references. The clinical feasibility and CFD studies were performed in clinically stented coronary bifurcations. The experimental and clinical studies showed that our algorithm (1) can reproduce the complex spatial stent configuration with high precision and reproducibility, (2) is feasible in 3D reconstructing stents deployed in bifurcations, and (3) enables CFD studies to assess the local hemodynamic environment within the stent. Notably, the high accuracy of our algorithm was consistent across different stent designs and diameters. Our method coupled with patient-specific CFD studies can lay the ground for optimization of stenting procedures, patient-specific computational stenting simulations, and research and development of new stent scaffolds and stenting techniques.
Collapse
Affiliation(s)
- Wei Wu
- Cardiovascular Biology and Biomechanics Laboratory, Cardiovascular Division, University of Nebraska Medical Center, 982265 Nebraska Medical Center, Omaha, NE, 68198, USA
| | - Behram Khan
- Cardiovascular Biology and Biomechanics Laboratory, Cardiovascular Division, University of Nebraska Medical Center, 982265 Nebraska Medical Center, Omaha, NE, 68198, USA
| | - Mohammadali Sharzehee
- Cardiovascular Biology and Biomechanics Laboratory, Cardiovascular Division, University of Nebraska Medical Center, 982265 Nebraska Medical Center, Omaha, NE, 68198, USA
| | - Shijia Zhao
- Cardiovascular Biology and Biomechanics Laboratory, Cardiovascular Division, University of Nebraska Medical Center, 982265 Nebraska Medical Center, Omaha, NE, 68198, USA
| | - Saurabhi Samant
- Cardiovascular Biology and Biomechanics Laboratory, Cardiovascular Division, University of Nebraska Medical Center, 982265 Nebraska Medical Center, Omaha, NE, 68198, USA
| | - Yusuke Watanabe
- Department of Cardiology, Teikyo University Hospital, Tokyo, Japan
| | - Yoshinobu Murasato
- Department of Cardiology, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan
| | | | | | | | - Thomas Valenzuela
- Visible Heart Laboratory, Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Paul A Iaizzo
- Visible Heart Laboratory, Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Janaki Makadia
- Cardiovascular Biology and Biomechanics Laboratory, Cardiovascular Division, University of Nebraska Medical Center, 982265 Nebraska Medical Center, Omaha, NE, 68198, USA
| | - Anastasios Panagopoulos
- Cardiovascular Biology and Biomechanics Laboratory, Cardiovascular Division, University of Nebraska Medical Center, 982265 Nebraska Medical Center, Omaha, NE, 68198, USA
| | - Francesco Burzotta
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS Università Cattolica del Sacro Cuore, Rome, Italy
| | - Habib Samady
- School of Medicine, Emory University, Atlanta, GA, USA
| | | | - George D Dangas
- Department of Cardiovascular Medicine, Mount Sinai Hospital, New York City, NY, USA
| | - Yves Louvard
- Institut Cardiovasculaire Paris Sud, Massy, France
| | - Goran Stankovic
- Department of Cardiology, Clinical Center of Serbia, Belgrade, Serbia
| | - Gabriele Dubini
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta,", Politecnico di Milano, Milan, Italy
| | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta,", Politecnico di Milano, Milan, Italy
| | | | - Elazer R Edelman
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Boston, MA, USA
| | - Claudio Chiastra
- PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Yiannis S Chatzizisis
- Cardiovascular Biology and Biomechanics Laboratory, Cardiovascular Division, University of Nebraska Medical Center, 982265 Nebraska Medical Center, Omaha, NE, 68198, USA.
| |
Collapse
|
46
|
Scafa Udriște A, Niculescu AG, Grumezescu AM, Bădilă E. Cardiovascular Stents: A Review of Past, Current, and Emerging Devices. MATERIALS (BASEL, SWITZERLAND) 2021; 14:2498. [PMID: 34065986 PMCID: PMC8151529 DOI: 10.3390/ma14102498] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 05/10/2021] [Accepted: 05/10/2021] [Indexed: 12/11/2022]
Abstract
One of the leading causes of morbidity and mortality worldwide is coronary artery disease, a condition characterized by the narrowing of the artery due to plaque deposits. The standard of care for treating this disease is the introduction of a stent at the lesion site. This life-saving tubular device ensures vessel support, keeping the blood-flow path open so that the cardiac muscle receives its vital nutrients and oxygen supply. Several generations of stents have been iteratively developed towards improving patient outcomes and diminishing adverse side effects following the implanting procedure. Moving from bare-metal stents to drug-eluting stents, and recently reaching bioresorbable stents, this research field is under continuous development. To keep up with how stent technology has advanced in the past few decades, this paper reviews the evolution of these devices, focusing on how they can be further optimized towards creating an ideal vascular scaffold.
Collapse
Affiliation(s)
- Alexandru Scafa Udriște
- Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania; (A.S.U.); (E.B.)
- Cardiology Department, Clinical Emergency Hospital Bucharest, 014461 Bucharest, Romania
| | - Adelina-Gabriela Niculescu
- Faculty of Engineering in Foreign Languages, University Politehnica of Bucharest, 060042 Bucharest, Romania;
| | - Alexandru Mihai Grumezescu
- Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 060042 Bucharest, Romania
- Research Institute of the University of Bucharest—ICUB, University of Bucharest, 050657 Bucharest, Romania
| | - Elisabeta Bădilă
- Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania; (A.S.U.); (E.B.)
- Internal Medicine Department, Clinical Emergency Hospital Bucharest, 014461 Bucharest, Romania
| |
Collapse
|
47
|
Bian D, Zhou X, Liu J, Li W, Shen D, Zheng Y, Gu W, Jiang J, Li M, Chu X, Ma L, Wang X, Zhang Y, Leeflang S, Zhou J. Degradation behaviors and in-vivo biocompatibility of a rare earth- and aluminum-free magnesium-based stent. Acta Biomater 2021; 124:382-397. [PMID: 33508506 DOI: 10.1016/j.actbio.2021.01.031] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 01/14/2021] [Accepted: 01/19/2021] [Indexed: 12/14/2022]
Abstract
Biodegradable stents can provide scaffolding and anti-restenosis benefits in the short term and then gradually disappear over time to free the vessel, among which the Mg-based biodegradable metal stents have been prosperously developed. In the present study, a Mg-8.5Li (wt.%) alloy (RE- and Al-free) with high ductility (> 40%) was processed into mini-tubes, and further fabricated into finished stent through laser cutting and electropolishing. In-vitro degradation test was performed to evaluate the durability of this stent before and after balloon dilation. The influence of plastic deformation and residual stress (derived from the dilation process) on the degradation was checked with the assistance of finite element analysis. In addition, in-vivo degradation behaviors and biocompatibility of the stent were evaluated by performing implantation in iliac artery of minipigs. The balloon dilation process did not lead to deteriorated degradation, and this stent exhibited a decent degradation rate (0.15 mm/y) in vitro, but divergent result (> 0.6 mm/y) was found in vivo. The stent was almost completely degraded in 3 months, revealing an insufficient scaffolding time. Meanwhile, it did not induce possible thrombus, and it was tolerable by surrounding tissues in pigs. Besides, endothelial coverage in 1 month was achieved even under the severe degradation condition. In the end, the feasibility of this stent for treatment of benign vascular stenosis was generally discussed, and perspectives on future improvement of Mg-Li-based stents were proposed.
Collapse
Affiliation(s)
- Dong Bian
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, China
| | - Xiaochen Zhou
- Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing, 100871, China
| | - Jianing Liu
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China
| | - Wenting Li
- Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing, 100871, China
| | - Danni Shen
- Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing, 100871, China
| | - Yufeng Zheng
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, China; Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing, 100871, China; Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China.
| | - Wenda Gu
- Department of Cardiac Surgery, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, China
| | - Jingjun Jiang
- Department of Vascular Surgery, Peking University People's Hospital, Beijing, 100044, China
| | - Mei Li
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, China
| | - Xiao Chu
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, China
| | - Limin Ma
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, China
| | - Xiaolan Wang
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, China
| | - Yu Zhang
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, China
| | - Sander Leeflang
- Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, Netherlands
| | - Jie Zhou
- Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, Netherlands
| |
Collapse
|
48
|
张 晗, 张 愉, 陈 诗, 崔 新, 彭 坤, 乔 爱. [Review of studies on the biomechanical modelling of the coupling effect between stent degradation and blood vessel remodeling]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2020; 37:956-966. [PMID: 33369334 PMCID: PMC9929987 DOI: 10.7507/1001-5515.202008007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Indexed: 11/03/2022]
Abstract
The dynamic coupling of stent degradation and vessel remodeling can influence not only the structural morphology and material property of stent and vessel, but also the development of in-stent restenosis. The research achievements of biomechanical modelling and analysis of stent degradation and vessel remodeling were reviewed; several noteworthy research perspectives were addressed, a stent-vessel coupling model was developed based on stent damage function and vessel growth function, and then concepts of matching ratio and risk factor were established so as to evaluate the treatment effect of stent intervention, which may lay the scientific foundation for the structure design, mechanical analysis and clinical application of biodegradable stent.
Collapse
Affiliation(s)
- 晗冰 张
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 愉 张
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 诗亮 陈
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 新阳 崔
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 坤 彭
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 爱科 乔
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| |
Collapse
|
49
|
He J, Hu X, Cao J, Zhang Y, Xiao J, Peng L, Chen D, Xiong C, Zhang L. Chitosan-coated hydroxyapatite and drug-loaded polytrimethylene carbonate/polylactic acid scaffold for enhancing bone regeneration. Carbohydr Polym 2020; 253:117198. [PMID: 33278972 DOI: 10.1016/j.carbpol.2020.117198] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 09/23/2020] [Accepted: 10/06/2020] [Indexed: 12/21/2022]
Abstract
Biocompatible polymers and drug-delivery scaffolds have driven development in bone regeneration. In this study, we fabricated a chitosan (CS)-coated polytrimethylene carbonate (PTMC)/polylactic acid (PLLA)/oleic acid-modified hydroxyapatite (OA-HA)/vancomycin hydrochloride (VH) microsphere scaffold for drug release with excellent biocompatibility. The incorporation of PLLA, OA-HA, and VH into PTMC microspheres not only slowed the biodegradability of the scaffold but also enhanced its mechanical properties and surface properties. Moreover, the CS coating stimulated extensive adhesion of osteoblasts before OA-HA incorporation, which facilitated the controlled release of OA-HA. The scaffolds were characterized via scanning electron microscopy, in vitro comprehensive performance testing, cell culturing, and microcomputer tomography scanning. The results indicated that the surface of the composite microsphere scaffold was suitable for osteoblast adhesion. Additionally, the release of OA-HA stimulated osteogenic proliferation. Our findings suggest that the CS-PTMC/PLLA/OA-HA/VH microsphere scaffold is promising for bone tissue engineering applications.
Collapse
Affiliation(s)
- Jian He
- Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xulin Hu
- Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jianfei Cao
- School of Materials and Environmental Engineering, Chengdu Technology University, Chengdu 610041, China
| | - Yu Zhang
- Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jianping Xiao
- Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China
| | - liJun Peng
- Changzhou Institude of Chemistry, Changzhou, Jiangsu 213000, China
| | - Dongliang Chen
- Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Chengdong Xiong
- Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lifang Zhang
- Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China; University of Chinese Academy of Sciences, Beijing 100049, China.
| |
Collapse
|
50
|
Zhao J, Feng Y. Surface Engineering of Cardiovascular Devices for Improved Hemocompatibility and Rapid Endothelialization. Adv Healthc Mater 2020; 9:e2000920. [PMID: 32833323 DOI: 10.1002/adhm.202000920] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 07/18/2020] [Indexed: 12/13/2022]
Abstract
Cardiovascular devices have been widely applied in the clinical treatment of cardiovascular diseases. However, poor hemocompatibility and slow endothelialization on their surface still exist. Numerous surface engineering strategies have mainly sought to modify the device surface through physical, chemical, and biological approaches to improve surface hemocompatibility and endothelialization. The alteration of physical characteristics and pattern topographies brings some hopeful outcomes and plays a notable role in this respect. The chemical and biological approaches can provide potential signs of success in the endothelialization of vascular device surfaces. They usually involve therapeutic drugs, specific peptides, adhesive proteins, antibodies, growth factors and nitric oxide (NO) donors. The gene engineering can enhance the proliferation, growth, and migration of vascular cells, thus boosting the endothelialization. In this review, the surface engineering strategies are highlighted and summarized to improve hemocompatibility and rapid endothelialization on the cardiovascular devices. The potential outlook is also briefly discussed to help guide endothelialization strategies and inspire further innovations. It is hoped that this review can assist with the surface engineering of cardiovascular devices and promote future advancements in this emerging research field.
Collapse
Affiliation(s)
- Jing Zhao
- School of Chemical Engineering and Technology Tianjin University Yaguan Road 135 Tianjin 300350 P. R. China
| | - Yakai Feng
- School of Chemical Engineering and Technology Tianjin University Yaguan Road 135 Tianjin 300350 P. R. China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin) Yaguan Road 135 Tianjin 300350 P. R. China
- Key Laboratory of Systems Bioengineering (Ministry of Education) Tianjin University Tianjin 300072 P. R. China
| |
Collapse
|