1
|
Quan C, Quan L, Wen Q, Yang M, Li T. Alanine aminotransferase electrochemical sensor based on graphene@MXene composite nanomaterials. Mikrochim Acta 2023; 191:45. [PMID: 38114837 DOI: 10.1007/s00604-023-06131-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 11/29/2023] [Indexed: 12/21/2023]
Abstract
Graphene@MXene composite nanomaterials were utilized to construct an electrochemical sensor for alanine aminotransferase (ALT) detection. The combination of graphene nanosheets with MXene avoids the self-stacking of MXene and graphene, and broadens the charge transfer channel. In addition, the composite nanomaterial provides increased loading sites for pyruvate oxidase. The principle of ALT detection is a two-step enzymatic reaction. L-Alanine was initially transferred to pyruvate catalyzed by ALT. The formed pyruvate was then oxidized by pyruvate oxidase, generating H2O2. Through the detection of the generated H2O2, ALT activity was measured. The linear range of the sensor to ALT was from 5 to 400 U·L-1 with a detection limit of 0.16 U·L-1 (S/N = 3). For real sample analysis, the spiked recovery test results of ALT in serum samples were between 96.89 and 103.93% with RSD < 5%, confirming the reliability of the sensor testing results and potential clinical application of the sensor.
Collapse
Affiliation(s)
- Changyun Quan
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China
- Cofoe Medical Technology Co., Ltd, No.816 Zhenghua Road, Changsha, 410000, China
| | | | - Qinying Wen
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China
| | - Minghui Yang
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China.
| | - Ting Li
- Department of Liver Transplantation, The Second Xiang-Ya Hospital, Central South University, Changsha, 410011, China.
| |
Collapse
|
2
|
Chinnappan R, Mir TA, Alsalameh S, Makhzoum T, Adeeb S, Al-Kattan K, Yaqinuddin A. Aptasensors Are Conjectured as Promising ALT and AST Diagnostic Tools for the Early Diagnosis of Acute Liver Injury. Life (Basel) 2023; 13:1273. [PMID: 37374056 DOI: 10.3390/life13061273] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 05/22/2023] [Accepted: 05/24/2023] [Indexed: 06/29/2023] Open
Abstract
Abnormal levels of alanine aminotransferase (ALT) and aspartate aminotransferase (AST) in human serum are the most sensitive indicator of hepatocellular damage. Because liver-related health problems are directly linked to elevated levels of ALT and AST, it is important to develop accurate and rapid methods to detect these enzymes for the early diagnosis of liver disease and prevention of long-term liver damage. Several analytical methods have been developed for the detection of ALT and AST. However, these methods are based on complex mechanisms and require bulky instruments and laboratories, making them unsuitable for point-of-care application or in-house testing. Lateral flow assay (LFA)-based biosensors, on the other hand, provide rapid, accurate, and reliable results, are easy to operate, and are affordable for low-income populations. However, due to the storage, stability, batch-to-batch variations, and error margins, antibody-based LFAs are considered unaffordable for field applications. In this hypothesis, we propose the selection of aptamers with high affinity and specificity for the liver biomarkers ALT and AST to build an efficient LFA device for point-of-care applications. Though the aptamer-based LFA would be semiquantitative for ALT and AST, it would be an inexpensive option for the early detection and diagnosis of liver disease. Aptamer-based LFA is anticipated to minimize the economic burden. It can also be used for routine liver function tests regardless of the economic situation in each country. By developing a low-cost testing platform, millions of patients suffering from liver disease can be saved.
Collapse
Affiliation(s)
- Raja Chinnappan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
- Tissue/Organ Bioengineering & BioMEMS Lab, Organ Transplant Centre of Excellence, Transplant Research & Innovation Department, King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Tanveer Ahmad Mir
- Tissue/Organ Bioengineering & BioMEMS Lab, Organ Transplant Centre of Excellence, Transplant Research & Innovation Department, King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | | | - Tariq Makhzoum
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| | - Salma Adeeb
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| | - Khaled Al-Kattan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| | - Ahmed Yaqinuddin
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| |
Collapse
|
3
|
Singh R, Wang Z, Marques C, Min R, Zhang B, Kumar S. Alanine aminotransferase detection using TIT assisted four tapered fiber structure-based LSPR sensor: From healthcare to marine life. Biosens Bioelectron 2023; 236:115424. [PMID: 37253306 DOI: 10.1016/j.bios.2023.115424] [Citation(s) in RCA: 24] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 05/14/2023] [Accepted: 05/22/2023] [Indexed: 06/01/2023]
Abstract
Alanine aminotransferase (ALT), a type of inactive enzyme largely present in fish liver cells, is essential for the tricarboxylic acid (TCA) cycle. Monitoring ALT activity in the blood/hepatocellular layer has been demonstrated to be a sensitive sign of liver dysfunction and an essential method for determining the health status of fish. This study details the development of a multi-layer material (hybrids of graphene oxide and multi-walled carbon nanotubes (GO/MWCNTs), gold nanoparticles (AuNPs), and glutamate oxidase (GluOx) enzyme) immobilized localized surface plasmon resonance based unique fiber structure biosensor for the quantitative determination of ALT biomolecules at concentrations ranging from 0 to 1000 U/L. For this kind of detection, a novel taper-in-taper with four tapered (TIT4T) structure based on single-mode fiber has been developed. In addition to AuNPs, GO/MWCNTs were immobilized in the probe's sensing region to increase its LSPR efficiency and sensitivity. Synthesis of AuNPs was carried out utilizing the Turkevich method. The selectivity of the sensor is ensured by the effective immobilization of GluOx on the surface treatment. The linearity of sensor is in the range of 0-1000 U/L, whereas the sensitivity, limit of detection, and detection time are individually found at 7.5 p.m./(U/L), 4.84 U/L and 20 min, respectively. After evaluating the prospective applications of the sensors, the sensors' reusability, reproducibility, stability, pH test, and selectivity have all been found to be satisfactory. Proposed fiber optic biosensors have high sensitivity, robustness, reliability, fast detection, no electromagnetic interference, low cost, real-time monitoring, and biocompatible.
Collapse
Affiliation(s)
- Ragini Singh
- College of Agronomy, Liaocheng University, Liaocheng, 252059, China
| | - Zhi Wang
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information Technology, Liaocheng University, Liaocheng, 252059, China
| | - Carlos Marques
- I3N & Physics Department, University of Aveiro, 3810-193, Aveiro, Portugal
| | - Rui Min
- Center for Cognition and Neuroergonomics, State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University at Zhuhai, 519087, Zhuhai, China
| | - Bingyuan Zhang
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information Technology, Liaocheng University, Liaocheng, 252059, China.
| | - Santosh Kumar
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information Technology, Liaocheng University, Liaocheng, 252059, China.
| |
Collapse
|
4
|
Lai W, Shi Y, Zhong J, Zhou X, Yang Y, Chen Z, Zhang C. A dry chemistry-based electrochemiluminescence device for point-of-care testing of alanine transaminase. Talanta 2023; 256:124287. [PMID: 36738623 DOI: 10.1016/j.talanta.2023.124287] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 01/17/2023] [Accepted: 01/18/2023] [Indexed: 01/22/2023]
Abstract
Liver disease causes serious public health problems because of its high prevalence, particularly affecting low- and middle-income countries. Alanine transaminase (ALT) is considered to be one of the most sensitive indicators for diagnosing liver disease. Although many strategies have been reported for ALT detection, few of them have solved the problem of automatic detection. In this work, for the first time, a dry chemistry-based electrochemiluminescence (DC-ECL) device is developed for point-of-care testing (POCT) of ALT, achieving real sample-to-answer detection. The proposed DC-ECL device consists of the following two components: (a) a DC-ECL chip consisting of the outer shell (including the top cap and pedestal) and detection layer (including the baseplate, electrode pad and carrier pad) and (b) an automatic ECL analyzer mainly including the data processing and instrument control unit, imaging detection unit, electrochemical reaction excitation unit, open detection window unit and rechargeable power supply. Under optimized conditions, the device had a wide detection range (0-1000 U/L), the ECL intensity linearly increased with ALT concentration (5-50 U/L) and logarithmic ALT concentration (50-1000 U/L), and the limit of detection was calculated to be 1.702 U/L. In addition, the DC-ECL device had the ability to measure ALT levels in human serum samples and showed acceptable selectivity, stability and repeatability. These results reveal that the DC-ECL device can overcome the disadvantages of traditional methods for ALT detection (such as high cost and requirement of professional technicians) and potentially opens the door to the development of similar POCT analyzers.
Collapse
Affiliation(s)
- Wei Lai
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Yanyang Shi
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Jinbiao Zhong
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Xinya Zhou
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Yang Yang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Zhenyu Chen
- Guangzhou First People's Hospital Nansha Hospital, Guangzhou, 511457, China
| | - Chunsun Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
| |
Collapse
|
5
|
Tian D, Xiang W, Wang H, Jiang W, Li T, Yang M. Optical assay using B-doped core-shell Fe@BC nanozyme for determination of alanine aminotransferase. Mikrochim Acta 2022; 189:147. [PMID: 35299258 DOI: 10.1007/s00604-021-05056-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Accepted: 10/07/2021] [Indexed: 12/01/2022]
Abstract
B-doped core-shell Fe@BC nanozyme was synthesized. The peroxidase (POD) like activity of Fe@BC nanozyme was studied and utilized for detecting the activity of alanine aminotransferase (ALT). In the presence of ALT as well as ALT co-substrates L-alanine and α-ketoglutarate, L-glutamate is generated. The following catalytic oxidation of L-glutamate by glutamate oxidase leads to the generation of H2O2. The POD-like activity of Fe@BC can oxidize 3,3',5,5'-tetramethylbenzidine (TMB) to oxTMB in the presence of H2O2, generating a blue-colored compound. Through the detection of the amount of H2O2 generated, ALT activity can be determined through measuring the absorbance intensity variation at 450 nm. The limit of detection of the assay is 4 U/L, with a linear range from 10 to 1000 U/L. For human serum samples, the ALT levels determined by our assay are comparable to those determined by the hospital with a correlation coefficient of 0.991, demonstrating the reliability of our assay results.
Collapse
Affiliation(s)
- Dazhi Tian
- Key Laboratory of Transplantation, Chinese Academy of Medical Sciences, Beijing, 100730, China.,Tianjin Key Laboratory for Organ Transplantation, Department of Liver Transplantation, Tianjin First Center Hospital, Tianjin, 300192, China
| | - Wen Xiang
- Tianjin Key Laboratory for Organ Transplantation, Department of Liver Transplantation, Tianjin First Center Hospital, Tianjin, 300192, China
| | - Hao Wang
- Tianjin Key Laboratory for Organ Transplantation, Department of Liver Transplantation, Tianjin First Center Hospital, Tianjin, 300192, China
| | - Wentao Jiang
- Key Laboratory of Transplantation, Chinese Academy of Medical Sciences, Beijing, 100730, China. .,Tianjin Key Laboratory for Organ Transplantation, Department of Liver Transplantation, Tianjin First Center Hospital, Tianjin, 300192, China.
| | - Ting Li
- Department of Organ Transplantation Center, The Second Xiang-Ya Hospital, Central South University, Changsha, 410011, China.
| | - Minghui Yang
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China
| |
Collapse
|
6
|
Yadav S, Jangra R, Sharma BR, Sharma M. Current Advancement in Biosensing techniques for determination of Alanine aminotransferase and Aspartate aminotransferase-a Mini Review. Process Biochem 2022. [DOI: 10.1016/j.procbio.2022.01.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
7
|
Liu X, Mei X, Yang J, Li Y. Hydrogel-Involved Colorimetric Platforms Based on Layered Double Oxide Nanozymes for Point-of-Care Detection of Liver-Related Biomarkers. ACS APPLIED MATERIALS & INTERFACES 2022; 14:6985-6993. [PMID: 35080175 DOI: 10.1021/acsami.1c21578] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Monitoring the liver status in a convenient and low-cost way is significant for obtaining a warning about drug-indued liver diseases promptly. Herein, we designed a novel colorimetric point-of-care (POC) platform for the determination of three liver-related biomarkers─aspartate transaminase (AST), alanine transaminase (ALT), and alkaline phosphatase (ALP). This platform integrated agarose hydrogels into a portable device, where hydrogels were loaded with nanozymes and different reaction substances for triggering specific reactions and generating colorimetric signals. Typically, Au-decorated CoAl-layered double oxide (Au/LDO) was for the first time developed as the nanozyme with peroxidase (POD) mimic activity, which can accelerate the oxidation of colorless 3,3',5,5'-tetramethylbenzidine (TMB) to blue oxTMB with the coexistence of hydrogen peroxide (H2O2). The detection mechanism of AST and ALT is based on the fact that they can cause individual cascade reactions to generate H2O2, and H2O2 further activates the Au/LDO nanozyme to catalyze the chromogenic reaction of TMB. As for ALP, it can catalytically hydrolyze l-ascorbic acid-2-phosphate to ascorbic acid. The latter then discolored the oxTMB that was produced with the assistance of Au/LDO. Teaming up with a smartphone, the color information of hydrogels can be converted to hue values, which allow quantitative analysis of ALT, AST, and ALP with detection limits of 15, 10, and 5 U/L, respectively. Moreover, the simple and cost-effective platform was successfully applied for the simultaneous determination of the three analytes in human plasma. Additionally, since the hydrogel is disposable and can be replaced by new ones loaded with different reaction regents, the platform is expected to serve the POC testing of various chem/bio targets.
Collapse
Affiliation(s)
- Xiaoxue Liu
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China
| | - Xuecui Mei
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China
| | - Jiao Yang
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China
| | - Yingchun Li
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China
| |
Collapse
|
8
|
Sha H, Yan B. Dye-functionalized metal-organic frameworks with the uniform dispersion of MnO 2 nanosheets for visualized fluorescence detection of alanine aminotransferase. NANOSCALE 2021; 13:20205-20212. [PMID: 34850792 DOI: 10.1039/d1nr05376k] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The wide applications of metal-organic framework (MOF) luminescent materials in the field of optics have attracted the general attention of researchers. Therefore, the development of simple and multifunctional MOF light-emitting platforms have become a research hotspot. The composites (MnO2@ZIF-8-luminol) were prepared by an in situ synthesis method and room-temperature covalent reaction. The composites and o-phenylenediamine (OPD) constitute a dual emission sensor for detecting alanine aminotransferase (ALT). OPD can be oxidized by MnO2 to 2,3-diaminophenazine (DAP) with yellow fluorescence emission, which inhibits the blue emission of luminol through fluorescence resonance energy transfer (FRET). The presence of tiopronin (TP) will destroy the FRET process, extinguishing the yellow fluorescence emission and restoring the blue fluorescence emission. The special effect between ALT and TP will further reverse the changes in the two fluorescent signals. Moreover, in the detection process, when the blue and yellow fluorescence energies in the system are within a certain range, a new white light emission will be generated, which causes the sensing of ALT to present ternary visualization. In addition, a high-security anti-counterfeiting platform is constructed by using the prepared materials and agarose hydrogels. The anti-counterfeiting platform can encrypt information on demand according to the luminous characteristics of different materials. This study not only provides a typical case of ternary visualization sensing by MOF-based materials but also develops a possible method for the construction of a MOF-based hydrogel anti-counterfeiting platform.
Collapse
Affiliation(s)
- Haifeng Sha
- Shanghai Key Lab of Chemical Assessment and Sustainability, School of Chemical Science and Engineering, Tongji University, Siping Road 1239, Shanghai 200092, P. R. China.
| | - Bing Yan
- Shanghai Key Lab of Chemical Assessment and Sustainability, School of Chemical Science and Engineering, Tongji University, Siping Road 1239, Shanghai 200092, P. R. China.
| |
Collapse
|
9
|
Soon GH, Deasy M, Dempsey E. An Electrochemical Evaluation of Novel Ferrocene Derivatives for Glutamate and Liver Biomarker Biosensing. BIOSENSORS 2021; 11:254. [PMID: 34436056 PMCID: PMC8392419 DOI: 10.3390/bios11080254] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 07/12/2021] [Accepted: 07/13/2021] [Indexed: 06/13/2023]
Abstract
Here, we present an evaluation of two new monosubstituted ferrocene (Fc) derivatives, 3-(1H-pyrrol-1-yl)propanamidoferrocene and 1-hydroxy-2-[2-(thiophen-3-yl)-ethylamino]ethylferrocene, as glutamate oxidase mediators, together with their preparation and characterisation. Taking into consideration the influence of the electronic effects of substituents on the redox potentials of the Fc species, two candidates with pyrrole or thiophene moieties were proposed for investigation. Film studies involved potential sweeping in the presence of pyrrole or 3,4-ethylenedioxythiophene monomers resulting in stable electroactive films with % signal loss upon cycling ranging from 1 to 7.82% and surface coverage (Γ) 0.47-1.15 × 10-9 mol/cm2 for films formed under optimal conditions. Construction of a glutamate oxidase modified electrode resulted in second-generation biosensing with the aid of both cyclic voltammetry and hydrodynamic amperometry, resulting in glutamate sensitivity of 0.86-1.28 μA/mM and Km (app) values over the range 3.67-5.01 mM. A follow-up enzyme assay for liver biomarker γ-glutamyl transpeptidase realised unmediated and mediated measurement establishing reaction and incubation time investigations and a realising response over <100 U/L γ-glutamyl transpeptidase with a sensitivity of 5 nA/UL-1.
Collapse
Affiliation(s)
- Geok Hong Soon
- Centre of Applied Science for Health (CASH), Technological University of Dublin, Tallaght, D24 FKT9 Dublin, Ireland; (G.H.S.); (M.D.)
| | - Mary Deasy
- Centre of Applied Science for Health (CASH), Technological University of Dublin, Tallaght, D24 FKT9 Dublin, Ireland; (G.H.S.); (M.D.)
| | - Eithne Dempsey
- Department of Chemistry, Kathleen Lonsdale Institute for Human Health, Maynooth University, Maynooth, W23 F2H6 Co. Kildare, Ireland
| |
Collapse
|
10
|
Li T, Cui X, Cui Y, Sun J, Chen Y, Zhu T, Li C, Li R, Wu B. Exploration of Transaminase Diversity for the Oxidative Conversion of Natural Amino Acids into 2-Ketoacids and High-Value Chemicals. ACS Catal 2020. [DOI: 10.1021/acscatal.0c01895] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Tao Li
- CAS Key Laboratory of Microbial Physiological and Metabolic Engineering, State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China
- University of Chinese Academy of Sciences, Beijing, 100101, PR China
| | - Xuexian Cui
- CAS Key Laboratory of Microbial Physiological and Metabolic Engineering, State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China
- University of Chinese Academy of Sciences, Beijing, 100101, PR China
| | - Yinglu Cui
- CAS Key Laboratory of Microbial Physiological and Metabolic Engineering, State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China
| | - Jinyuan Sun
- CAS Key Laboratory of Microbial Physiological and Metabolic Engineering, State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China
| | - Yanchun Chen
- CAS Key Laboratory of Microbial Physiological and Metabolic Engineering, State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China
- University of Chinese Academy of Sciences, Beijing, 100101, PR China
| | - Tong Zhu
- CAS Key Laboratory of Microbial Physiological and Metabolic Engineering, State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China
- University of Chinese Academy of Sciences, Beijing, 100101, PR China
| | - Chuijian Li
- CAS Key Laboratory of Microbial Physiological and Metabolic Engineering, State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China
| | - Ruifeng Li
- CAS Key Laboratory of Microbial Physiological and Metabolic Engineering, State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China
- University of Chinese Academy of Sciences, Beijing, 100101, PR China
| | - Bian Wu
- CAS Key Laboratory of Microbial Physiological and Metabolic Engineering, State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China
| |
Collapse
|
11
|
Sun Y, Nguyen TNH, Anderson A, Cheng X, Gage TE, Lim J, Zhang Z, Zhou H, Rodolakis F, Zhang Z, Arslan I, Ramanathan S, Lee H, Chubykin AA. In Vivo Glutamate Sensing inside the Mouse Brain with Perovskite Nickelate-Nafion Heterostructures. ACS APPLIED MATERIALS & INTERFACES 2020; 12:24564-24574. [PMID: 32383375 DOI: 10.1021/acsami.0c02826] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Glutamate, one of the main neurotransmitters in the brain, plays a critical role in communication between neurons, neuronal development, and various neurological disorders. Extracellular measurement of neurotransmitters such as glutamate in the brain is important for understanding these processes and developing a new generation of brain-machine interfaces. Here, we demonstrate the use of a perovskite nickelate-Nafion heterostructure as a promising glutamate sensor with a low detection limit of 16 nM and a response time of 1.2 s via amperometric sensing. We have designed and successfully tested novel perovskite nickelate-Nafion electrodes for recording of glutamate release ex vivo in electrically stimulated brain slices and in vivo from the primary visual cortex (V1) of awake mice exposed to visual stimuli. These results demonstrate the potential of perovskite nickelates as sensing media for brain-machine interfaces.
Collapse
Affiliation(s)
- Yifei Sun
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Tran N H Nguyen
- Birck Nanotechnology Center, Center for Implantable Device, Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Adam Anderson
- Department of Biological Sciences, Purdue Institute for Integrative Neuroscience, Purdue University, West Lafayette, Indiana 47907, United States
| | - Xi Cheng
- Department of Biological Sciences, Purdue Institute for Integrative Neuroscience, Purdue University, West Lafayette, Indiana 47907, United States
| | - Thomas E Gage
- Center for Nanoscale Materials, Argonne National Laboratory, Lemont, Illinois 60439, United States
| | - Jongcheon Lim
- Birck Nanotechnology Center, Center for Implantable Device, Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Zhan Zhang
- X-ray Science Division, Advanced Photon Source, Argonne National Laboratory, Lemont, Illinois 60439, United States
| | - Hua Zhou
- X-ray Science Division, Advanced Photon Source, Argonne National Laboratory, Lemont, Illinois 60439, United States
| | - Fanny Rodolakis
- X-ray Science Division, Advanced Photon Source, Argonne National Laboratory, Lemont, Illinois 60439, United States
| | - Zhen Zhang
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Ilke Arslan
- Center for Nanoscale Materials, Argonne National Laboratory, Lemont, Illinois 60439, United States
| | - Shriram Ramanathan
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Hyowon Lee
- Birck Nanotechnology Center, Center for Implantable Device, Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Alexander A Chubykin
- Department of Biological Sciences, Purdue Institute for Integrative Neuroscience, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
12
|
Marquitan M, Mark MD, Ernst A, Muhs A, Herlitze S, Ruff A, Schuhmann W. Glutamate detection at the cellular level by means of polymer/enzyme multilayer modified carbon nanoelectrodes. J Mater Chem B 2020; 8:3631-3639. [DOI: 10.1039/c9tb02461a] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Carbon nanoelectrodes in the sub-micron range were modified with an enzyme cascade immobilized in a spatially separated polymer double layer system for the detection of glutamate at the cellular level.
Collapse
Affiliation(s)
- Miriam Marquitan
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Melanie D. Mark
- Department of General Zoology and Neurobiology Ruhr University Bochum Universitätsstr. 150
- D-44780 Bochum
- Germany
| | - Andrzej Ernst
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Anna Muhs
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Stefan Herlitze
- Department of General Zoology and Neurobiology Ruhr University Bochum Universitätsstr. 150
- D-44780 Bochum
- Germany
| | - Adrian Ruff
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| | - Wolfgang Schuhmann
- Analytical Chemistry – Center for Electrochemical Sciences (CES)
- Faculty of Chemistry and Biochemistry
- Ruhr University Bochum
- D-44780 Bochum
- Germany
| |
Collapse
|
13
|
Ibadullaeva SZ, Appazov NO, Tarahovsky YS, Zamyatina EA, Fomkina MG, Kim YA. Amperometric Multi-Enzyme Biosensors: Development and Application, a Short Review. Biophysics (Nagoya-shi) 2019. [DOI: 10.1134/s0006350919050063] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
|
14
|
Saygili E, Orakci B, Koprulu M, Demirhan A, Ilhan-Ayisigi E, Kilic Y, Yesil-Celiktas O. Quantitative determination of H 2O 2 for detection of alanine aminotransferase using thin film electrodes. Anal Biochem 2019; 591:113538. [PMID: 31830435 DOI: 10.1016/j.ab.2019.113538] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 11/21/2019] [Accepted: 12/07/2019] [Indexed: 11/16/2022]
Abstract
The abnormal concentrations or absence of biomolecules (e.g., proteins) in blood can further be used in diagnosis of a particular pathology at an early stage. Current studies are intensely focusing on the analysis of interaction and detection of biomolecules via point-of-care systems (POCs), allowing miniaturized and parallelized reactions, simultaneously. Recent developments have shown that the collaboration of electrochemical sensing techniques and POCs to overcome challenging problems in health-care settings provides new approaches in diagnosis and treatment of diseases. The aim of this study was to adapt the alanine aminotransferase (ALT) enzyme to the platinum (Pt) thin film electrode system and quantitatively determine the enzyme levels via enzymatically generated H2O2 with differential pulse voltammetry (DPV). A simple potentiostat architecture with expanded sweep range utilizing dual LMP91000 devices was developed and adapted to the needs of the biosensor. In order to calibrate the system, known concentrations of H2O2 were also tested. Moreover, signals associated with the other electroactive species coming from the ALT reaction were eliminated. Resulted potential range has been achieved between +500 mV and +900 mV and the linear range was found to be 0.05 M-0.5 M for H2O2, whereas 5 UL-1 to 120 UL-1 for ALT enzyme.
Collapse
Affiliation(s)
- Ecem Saygili
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100, Bornova, Izmir, Turkey
| | - Beyza Orakci
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100, Bornova, Izmir, Turkey
| | - Melisa Koprulu
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100, Bornova, Izmir, Turkey
| | - Alper Demirhan
- Solar Biyoteknoloji Ltd. (SolarBiotec), 35530, Bayrakli, Izmir, Turkey
| | - Esra Ilhan-Ayisigi
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100, Bornova, Izmir, Turkey; Genetic and Bioengineering Department, Faculty of Engineering and Architecture, Ahi Evran University, Kirsehir, Turkey
| | - Yalin Kilic
- Department of Biomedical Engineering, Faculty of Engineering, Izmir University of Economics, 35330, Balcova, Izmir, Turkey
| | - Ozlem Yesil-Celiktas
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100, Bornova, Izmir, Turkey.
| |
Collapse
|
15
|
Moed S, Zaman MH. A quantitative electrochemical assay for liver injury. Biosens Bioelectron 2019; 131:74-78. [PMID: 30826653 DOI: 10.1016/j.bios.2019.02.032] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 01/25/2019] [Accepted: 02/01/2019] [Indexed: 10/27/2022]
Abstract
Liver diseases represent a vastly underestimated and historically neglected public health problem, disproportionately affecting those in low- and middle- income countries (LMICs). Patients on hepatotoxic medications, such as HIV and TB medications, need consistent monitoring of liver function as part of their standard of care. In high resource settings, this is often the case, but in LMICs traditional methods fail due to high cost and lack of proper equipment, supplies and trained personnel. To address this gap in technology and patient care, we have developed a quantitative, electrochemical assay capable of quantifying levels of alanine aminotransferase (ALT), a primary biomarker associated with liver function. We can quantify ALT with increased sensitivity (1.53 nA/(U/L*mm2) and over a wide, linear concentration range (40-1990 U/L). The assay demonstrated in this study can be used to overcome several pressing challenges associated with effective, timely treatment of liver disease in LMICs.
Collapse
Affiliation(s)
- Saundria Moed
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, United States.
| | - Muhammad H Zaman
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, United States; Howard Hughes Medical Institute, Boston University, Boston, MA 02215, United States.
| |
Collapse
|
16
|
Huang Y, Xu J, Liu J, Wang X, Chen B. Disease-Related Detection with Electrochemical Biosensors: A Review. SENSORS (BASEL, SWITZERLAND) 2017; 17:E2375. [PMID: 29039742 PMCID: PMC5676665 DOI: 10.3390/s17102375] [Citation(s) in RCA: 69] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 10/10/2017] [Accepted: 10/14/2017] [Indexed: 01/05/2023]
Abstract
Rapid diagnosis of diseases at their initial stage is critical for effective clinical outcomes and promotes general public health. Classical in vitro diagnostics require centralized laboratories, tedious work and large, expensive devices. In recent years, numerous electrochemical biosensors have been developed and proposed for detection of various diseases based on specific biomarkers taking advantage of their features, including sensitivity, selectivity, low cost and rapid response. This article reviews research trends in disease-related detection with electrochemical biosensors. Focus has been placed on the immobilization mechanism of electrochemical biosensors, and the techniques and materials used for the fabrication of biosensors are introduced in details. Various biomolecules used for different diseases have been listed. Besides, the advances and challenges of using electrochemical biosensors for disease-related applications are discussed.
Collapse
Affiliation(s)
- Ying Huang
- Chongqing Key Laboratory of Non-linear Circuit and Intelligent Information Processing, College of Electronic and Information Engineering, Southwest University, Chongqing 400715, China.
| | - Jin Xu
- Chongqing Key Laboratory of Non-linear Circuit and Intelligent Information Processing, College of Electronic and Information Engineering, Southwest University, Chongqing 400715, China.
| | - Junjie Liu
- Chongqing Key Laboratory of Non-linear Circuit and Intelligent Information Processing, College of Electronic and Information Engineering, Southwest University, Chongqing 400715, China.
| | - Xiangyang Wang
- CET-College of Engineering and Technology, Southwest University, Chongqing 400715, China.
| | - Bin Chen
- Chongqing Key Laboratory of Non-linear Circuit and Intelligent Information Processing, College of Electronic and Information Engineering, Southwest University, Chongqing 400715, China.
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University) Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400715, China.
| |
Collapse
|
17
|
Kitikul J, Satienperakul S, Preechaworapun A, Pookmanee P, Tangkuaram T. A Simple Flow Amperometric Electrochemical Biosensor Based on Chitosan Scaffolds and Gold Nanowires Modified on a Glassy Carbon Electrode for Detection of Glutamate in Food Products. ELECTROANAL 2016. [DOI: 10.1002/elan.201600263] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Affiliation(s)
- Jiraporn Kitikul
- Chemistry Program; Faculty of Science; Maejo University; Chiang Mai 50290 Thailand
| | | | - Anchana Preechaworapun
- Department of Chemistry; Faculty of Science and Technology; Pibulsongkram Rajabhat University; Phitsanulok 65000 Thailand
| | - Pusit Pookmanee
- Chemistry Program; Faculty of Science; Maejo University; Chiang Mai 50290 Thailand
| | - Tanin Tangkuaram
- Chemistry Program; Faculty of Science; Maejo University; Chiang Mai 50290 Thailand
| |
Collapse
|
18
|
Thuy TNT, Tseng TTC. A Micro-Platinum Wire Biosensor for Fast and Selective Detection of Alanine Aminotransferase. SENSORS 2016; 16:s16060767. [PMID: 27240366 PMCID: PMC4934193 DOI: 10.3390/s16060767] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2016] [Revised: 05/20/2016] [Accepted: 05/23/2016] [Indexed: 11/26/2022]
Abstract
In this study, a miniaturized biosensor based on permselective polymer layers (overoxidized polypyrrole (Ppy) and Nafion®) modified and enzyme (glutamate oxidase (GlutOx)) immobilized micro-platinum wire electrode for the detection of alanine aminotransferase (ALT) was fabricated. The proposed ALT biosensor was measured electrochemically by constant potential amperometry at +0.7 V vs. Ag/AgCl. The ALT biosensor provides fast response time (~5 s) and superior selectivity towards ALT against both negatively and positively charged species (e.g., ascorbic acid (AA) and dopamine (DA), respectively). The detection range of the ALT biosensor is found to be 10–900 U/L which covers the range of normal ALT levels presented in the serum and the detection limit and sensitivity are found to be 8.48 U/L and 0.059 nA/(U/L·mm2) (N = 10), respectively. We also found that one-day storage of the ALT biosensor at −20 °C right after the sensor being fabricated can enhance the sensor sensitivity (1.74 times higher than that of the sensor stored at 4 °C). The ALT biosensor is stable after eight weeks of storage at −20 °C. The sensor was tested in spiked ALT samples (ALT activities: 20, 200, 400, and 900 U/L) and reasonable recoveries (70%~107%) were obtained.
Collapse
Affiliation(s)
- Tran Nguyen Thanh Thuy
- Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
| | - Tina T-C Tseng
- Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
| |
Collapse
|
19
|
Chen M, Rong L, Chen X. A simple and sensitive detection of glutamic-pyruvic transaminase activity based on fluorescence quenching of bovine serum albumin. RSC Adv 2015. [DOI: 10.1039/c5ra24162f] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
It is well known that Cu(ii) can coordinate withl-alanine (Cu–Ala), which can be destroyed through the addition of glutamic-pyruvic transaminase (GPT) since GPT can effectively catalyze the conversion ofl-alanine into keto-acetic acid.
Collapse
Affiliation(s)
- Miao Chen
- College of Chemistry and Chemical Engineering
- Central South University
- Changsha 410083
- China
| | - Liya Rong
- College of Chemistry and Chemical Engineering
- Central South University
- Changsha 410083
- China
| | - Xiaoqing Chen
- College of Chemistry and Chemical Engineering
- Central South University
- Changsha 410083
- China
- Collaborative Innovation Center of Resource-conserving & Environment-friendly Society and Ecological Civilization
| |
Collapse
|
20
|
Abstract
Long-term stability is a key property of enzyme membranes that can be used for biosensors, bioreactors, and bio-fuel cells. This review discusses factors that decrease the stability, and provides two examples of enzyme membranes, a polyion complex membrane and a cellulose membrane, with which stability loss can be avoided. By using these materials, long-term stability was improved. These supporting materials could be applied to construct biosensors, bioreactors, and bio-fuel cells.
Collapse
Affiliation(s)
- Soichi Yabuki
- National Institute of Advanced Industrial Science and Technology
| |
Collapse
|
21
|
Yabuki S, Iwamoto M, Hirata Y. Long-Term Stability of a Cellulose-Based Glucose Oxidase Membrane. MATERIALS (BASEL, SWITZERLAND) 2014; 7:899-905. [PMID: 28788492 PMCID: PMC5453101 DOI: 10.3390/ma7020899] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2013] [Revised: 01/22/2014] [Accepted: 01/23/2014] [Indexed: 11/16/2022]
Abstract
A cellulose-based glucose oxidase membrane was prepared on a glassy carbon (GC) electrode. The current response of the electrode to glucose was measured by applying a potential of 1.0 V vs. Ag/AgCl on the base GC and was proportional to the concentration of glucose up to 1 mM. The long-term stability of the electrode was examined by measuring the daily glucose response. Over four months, the response magnitude was maintained and then gradually decreased. After 11 months, though the response magnitude decreased to 50% of the initial value, the linear response range did not change. Therefore, the electrode could be used as a glucose biosensor even after 11 months of use. The entrapment of the enzyme in the cellulose matrix promoted the stability of the enzyme, as revealed by data on the enzyme activity after the enzyme electrode was immersed in urea. Therefore, the cellulose matrix may be used to improve the performance of biosensors, bioreactors and bio-fuel cells.
Collapse
Affiliation(s)
- Soichi Yabuki
- National Institute of Advanced Industrial Science and Technology, Higashi 1-1-1, Tsukuba, Ibaraki 305-8566, Japan.
| | - Miho Iwamoto
- National Institute of Advanced Industrial Science and Technology, Higashi 1-1-1, Tsukuba, Ibaraki 305-8566, Japan.
| | - Yoshiki Hirata
- National Institute of Advanced Industrial Science and Technology, Higashi 1-1-1, Tsukuba, Ibaraki 305-8566, Japan.
| |
Collapse
|
22
|
Cascadic multienzyme reaction-based electrochemical biosensors. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2013. [PMID: 23828506 DOI: 10.1007/10_2013_228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register]
Abstract
: Since the first glucose biosensor was developed by Clark and Lyons, there have been great efforts to develop effective enzyme biosensors for wide applications. Those efforts are closely related to the enhancement of biosensor performance, including sensitivity improvement, elevation of selectivity, and extension of the range of analytes that may be determined. Introduction of a cascadic multienzyme reaction to the electrochemical biosensor is one of those efforts. By employing more than two enzymes to the biosensor, its sensitivity and accuracy can be enhanced. Also, the narrow application range that is a typical limitation of single enzyme-based biosensor can be overcome. This chapter will discuss the fundamental principles for the development of cascadic multienzyme reaction-based electrochemical biosensors and their applications in clinical and environmental fields.
Collapse
|
23
|
Disposable sensor based on enzyme-free Ni nanowire array electrode to detect glutamate. Biosens Bioelectron 2013; 40:213-8. [DOI: 10.1016/j.bios.2012.07.024] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Revised: 07/03/2012] [Accepted: 07/15/2012] [Indexed: 11/21/2022]
|
24
|
Hydrogen peroxide detection at a horseradish peroxidase biosensor with a Au nanoparticle–dotted titanate nanotube|hydrophobic ionic liquid scaffold. Biosens Bioelectron 2012; 32:188-94. [DOI: 10.1016/j.bios.2011.12.002] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2011] [Revised: 11/29/2011] [Accepted: 12/01/2011] [Indexed: 11/23/2022]
|
25
|
YABUKI S, HIRATA Y, SATO Y, IIJIMA S. Preparation of a Cellulose-based Enzyme Membrane Using Ionic Liquid to Lengthen the Duration of Enzyme Stability. ANAL SCI 2012; 28:373-7. [DOI: 10.2116/analsci.28.373] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Soichi YABUKI
- Division of Biomedical Research, National Institute of Advanced Industrial Science and Technology (AIST)
| | - Yoshiki HIRATA
- Division of Biomedical Research, National Institute of Advanced Industrial Science and Technology (AIST)
| | - Yuko SATO
- Division of Biomedical Research, National Institute of Advanced Industrial Science and Technology (AIST)
| | - Seiichiro IIJIMA
- Division of Biomedical Research, National Institute of Advanced Industrial Science and Technology (AIST)
| |
Collapse
|
26
|
Chu Z, Shi L, Zhang Y, Jin W, Warren S, Ward D, Dempsey E. Single layer Prussian blue grid as a versatile enzyme trap for low-potential biosensors. ACTA ACUST UNITED AC 2012. [DOI: 10.1039/c2jm33083k] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
27
|
Hsueh CJ, Wang JH, Dai L, Liu CC. Determination of alanine aminotransferase with an electrochemical nano ir-C biosensor for the screening of liver diseases. BIOSENSORS-BASEL 2011; 1:107-17. [PMID: 25586923 PMCID: PMC4264364 DOI: 10.3390/bios1030107] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2011] [Revised: 06/15/2011] [Accepted: 07/01/2011] [Indexed: 11/16/2022]
Abstract
Alanine aminotransaminase (ALT), is an enzyme that normally resides in serum and body tissues, especially in the liver. It is released into the serum as a result of tissue injury; hence the concentration of ALT in the serum may be increased with acute damage to hepatic cells. A single use, disposable biosensor, comprising iridium nano-particle as catalyst dispersed on carbon paste, has been developed for the determination of ALT concentration. The biosensor is based on quantifying H2O2 concentration produced by a serial of ALT enzymatic reactions. It operates well at room temperature in different physiological fluids: phosphate buffer, calf serum and human serum for ALT concentration of 0–544 ng/mL. Experimental results in human serum are compared to those obtained by spectrophotometric assays with excellent agreement. Therefore, the Ir/C biosensor shows good relationship on the dilution of concentrated ALT clinical applications.
Collapse
Affiliation(s)
- Chang-Jung Hsueh
- Department of Chemical Engineering and Electronics Design Center, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA.
| | - Joanne H Wang
- Department of Biology, Brown University, 69 Brown Street, Providence, RI 02912, USA.
| | - Liming Dai
- Department of Chemical Engineering and Electronics Design Center, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA.
| | - Chung-Chiun Liu
- Department of Chemical Engineering and Electronics Design Center, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA.
| |
Collapse
|
28
|
Disposable biosensor based on immobilisation of glutamate oxidase on Pt nanoparticles modified Au nanowire array electrode. Biosens Bioelectron 2010; 26:1420-4. [DOI: 10.1016/j.bios.2010.07.071] [Citation(s) in RCA: 76] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2010] [Revised: 07/14/2010] [Accepted: 07/19/2010] [Indexed: 11/21/2022]
|
29
|
Affiliation(s)
- Benjamin J Privett
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, USA
| | | | | |
Collapse
|