1
|
Traditional vs. Microfluidic Synthesis of ZnO Nanoparticles. Int J Mol Sci 2023; 24:ijms24031875. [PMID: 36768199 PMCID: PMC9916368 DOI: 10.3390/ijms24031875] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 01/12/2023] [Accepted: 01/16/2023] [Indexed: 01/19/2023] Open
Abstract
Microfluidics provides a precise synthesis of micro-/nanostructures for various applications, including bioengineering and medicine. In this review article, traditional and microfluidic synthesis methods of zinc oxide (ZnO) are compared concerning particle size distribution, morphology, applications, reaction parameters, used reagents, and microfluidic device materials. Challenges of traditional synthesis methods are reviewed in a manner where microfluidic approaches may overcome difficulties related to synthesis precision, bulk materials, and reproducibility.
Collapse
|
2
|
Guo JB, Cheng JS, Wei TL, Wu FM, Tang GH, He QH. An Immuno-Separated Assay for Ochratoxin Detection Coupled with a Nano-Affinity Cleaning-Up for LC-Confirmation. Foods 2022; 11:1155. [PMID: 35454740 PMCID: PMC9026555 DOI: 10.3390/foods11081155] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 04/02/2022] [Accepted: 04/07/2022] [Indexed: 02/01/2023] Open
Abstract
An immuno-separated assay for ochratoxin A detection coupled with a nano-affinity cleaning up for LC-confirmation was developed. Firstly, ochratoxin A was modified to quantum dot beads for immuno-fluorescent reporters. Secondly, Fe3O4 magnetic nanoparticles were conjugated with protein G for immuno-magnetic adsorbents. The immuno-separation of fluorescent reporters by magnetic adsorbents could be completed by ochratoxin A, so the fluorescent reporters released from the immune complex indicate a linear correlation with the concentration of ochratoxin A. Furthermore, the immuno-separated ochratoxin A can be eluted from magnetic adsorbent for LC-conformation. The optimized assay showed results as follows: the quantitative range of the immuno-separated assay was 0.03-100 ng mL-1 of ochratoxin A. The recoveries for spiked samples ranged from 78.2% to 91.4%, with the relative standard deviation (RSD) being 11.9%~15.3%. Statistical analysis indicated no significant difference between the HPLC-FLD results based on commercial affinity column and by nano-affinity cleaning up.
Collapse
Affiliation(s)
- Jie-Biao Guo
- Provincial Key Laboratory for Utilization and Conservation of Food and Medicinal Research in Northern Guangdong, Shaoguan University, No. 288 Daxue Road, Shaoguan 512005, China
| | - Jin-Sheng Cheng
- School of Innovation and Entrepreneurship, Shaoguan University, No. 288 Daxue Road, Shaoguan 512005, China;
| | - Tai-Long Wei
- State Key Laboratory of Food Science and Technology, Sino-Germany Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047, China;
| | - Fan-Min Wu
- Shaoguan Food and Drug Inspection Institute, No.13 Muxi Road, Shaoguan 512026, China; (F.-M.W.); (G.-H.T.)
| | - Gui-Hong Tang
- Shaoguan Food and Drug Inspection Institute, No.13 Muxi Road, Shaoguan 512026, China; (F.-M.W.); (G.-H.T.)
| | - Qing-Hua He
- State Key Laboratory of Food Science and Technology, Sino-Germany Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047, China;
| |
Collapse
|
3
|
Guo JB, Wei TL, He QH, Cheng JS, Qiu XZ, Liu WP, Lan XQ, Chen LF, Guo M. A magnetic-separation-based homogeneous immunosensor for the detection of deoxynivalenol coupled with a nano-affinity cleaning up for LC-MS/MS confirmation. FOOD AGR IMMUNOL 2021. [DOI: 10.1080/09540105.2021.1886254] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Affiliation(s)
- Jie-Biao Guo
- Shaoguan College, Shaoguan, People’s Republic of China
| | - Tai-Long Wei
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, People’s Republic of China
- Sino-German Joint Research Institute, Nanchang University, Nanchang, People’s Republic of China
| | - Qing-Hua He
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, People’s Republic of China
- Sino-German Joint Research Institute, Nanchang University, Nanchang, People’s Republic of China
- Jiangxi Province Key Laboratory of Modern Analytical Science, Nanchang University, Nanchang, People’s Republic of China
| | | | - Xiu-Zhen Qiu
- Shaoguan College, Shaoguan, People’s Republic of China
| | - Wang-Pei Liu
- Shaoguan Food and Drug Inspection Institute, Shaoguan, People’s Republic of China
| | - Xian-Quan Lan
- Shaoguan Food and Drug Inspection Institute, Shaoguan, People’s Republic of China
| | - Lu-Fen Chen
- Comprehensive Technology Service Center of Shaoguan Customs, Shaoguan, People’s Republic of China
| | - Min Guo
- Comprehensive Technology Service Center of Shaoguan Customs, Shaoguan, People’s Republic of China
| |
Collapse
|
4
|
Chang H, Kim J, Lee SH, Rho WY, Lee JH, Jeong DH, Jun BH. Luminescent Nanomaterials (II). ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1309:97-132. [PMID: 33782870 DOI: 10.1007/978-981-33-6158-4_5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
In this review, we focus on sensing techniques and biological applications of various luminescent nanoparticles including quantum dot (QD), up-conversion nanoparticles (UCNPs) following the previous chapter. Fluorescent phenomena can be regulated or shifted by interaction between biological targets and luminescence probes depending on their distance, which is so-called Fӧrster resonance energy transfer (FRET). QD-based FRET technique, which has been widely applied as a bioanalytical tool, is described. We discuss time-resolved fluorescence (TRF) imaging and flow cytometry technique, using photoluminescent nanoparticles with unique properties for effectively improving selectivity and sensitivity. Based on these techniques, bioanalytical and biomedical application, bioimaging with QD, UCNPs, and Euripium-activated luminescent nanoprobes are covered. Combination of optical property of these luminescent nanoparticles with special functions such as drug delivery, photothermal therapy (PTT), and photodynamic therapy (PDT) is also described.
Collapse
Affiliation(s)
- Hyejin Chang
- Division of Science Education, Kangwon National University, Chuncheon, Republic of Korea
| | - Jaehi Kim
- Department of Bioscience and Biotechnology, Konkuk University, Seoul, South Korea
| | - Sang Hun Lee
- Department of Chemical and Biological Engineering, Hanbat National University, Daejeon, Republic of Korea
| | - Won-Yeop Rho
- School of International Engineering and Science, Jeonbuk National University, Jeonju, Republic of Korea
| | - Jong Hun Lee
- Department of Food Science and Biotechnology, Gachon University, Seongnam, Republic of Korea
| | - Dae Hong Jeong
- Department of Chemistry Education, Seoul National University, Seoul, Republic of Korea
| | - Bong-Hyun Jun
- Department of Bioscience and Biotechnology, Konkuk University, Seoul, South Korea.
| |
Collapse
|
5
|
Enhanced fluorescence detection of proteins using ZnO nanowires integrated inside microfluidic chips. Biosens Bioelectron 2018; 99:368-374. [DOI: 10.1016/j.bios.2017.08.003] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 07/22/2017] [Accepted: 08/02/2017] [Indexed: 11/22/2022]
|
6
|
Damborska D, Bertok T, Dosekova E, Holazova A, Lorencova L, Kasak P, Tkac J. Nanomaterial-based biosensors for detection of prostate specific antigen. Mikrochim Acta 2017; 184:3049-3067. [PMID: 29109592 PMCID: PMC5669453 DOI: 10.1007/s00604-017-2410-1] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Screening serum for the presence of prostate specific antigen (PSA) belongs to the most common approach for the detection of prostate cancer. This review (with 156 refs.) addresses recent developments in PSA detection based on the use of various kinds of nanomaterials. It starts with an introduction into the field, the significance of testing for PSA, and on current limitations. A first main section treats electrochemical biosensors for PSA, with subsections on methods based on the use of gold electrodes, graphene or graphene-oxide, carbon nanotubes, hybrid nanoparticles, and other types of nanoparticles. It also covers electrochemical methods based on the enzyme-like activity of PSA, on DNA-, aptamer- and biofuel cell-based methods, and on the detection of PSA via its glycan part. The next main section covers optical biosensors, with subsections on methods making use of surface plasmon resonance (SPR), localized SPR and plasmonic ELISA-like schemes. This is followed by subsections on methods based on the use of fiber optics, fluorescence, chemiluminescence, Raman scattering and SERS, electrochemiluminescence and cantilever-based methods. The most sensitive biosensors are the electrochemical ones, with lowest limits of detection (down to attomolar concentrations), followed by mass cantilever sensing and electrochemilumenescent strategies. Optical biosensors show lower performance, but are still more sensitive compared to standard ELISA. The most commonly applied nanomaterials are metal and carbon-based ones and their hybrid composites used for different amplification strategies. The most attractive sensing schemes are summarized in a Table. The review ends with a section on conclusions and perspectives.
Collapse
Affiliation(s)
- Dominika Damborska
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Tomas Bertok
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Erika Dosekova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Alena Holazova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Lenka Lorencova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Peter Kasak
- Center for Advanced Materials, Qatar University, P.O. Box 2713, Doha, Qatar
| | - Jan Tkac
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| |
Collapse
|
7
|
Moro L, Turemis M, Marini B, Ippodrino R, Giardi MT. Better together: Strategies based on magnetic particles and quantum dots for improved biosensing. Biotechnol Adv 2017; 35:51-63. [DOI: 10.1016/j.biotechadv.2016.11.007] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 09/29/2016] [Accepted: 11/27/2016] [Indexed: 12/14/2022]
|
8
|
Liu W, Zhang A, Xu G, Wei F, Yang J, Hu Q. Manganese modified CdTe/CdS quantum dots as an immunoassay biosensor for the detection of Golgi protein-73. J Pharm Biomed Anal 2016; 117:18-25. [DOI: 10.1016/j.jpba.2015.08.020] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2015] [Revised: 08/09/2015] [Accepted: 08/14/2015] [Indexed: 01/01/2023]
|
9
|
Kazimierczak B, Pijanowska D, Baraniecka A, Dawgul M, Kruk J, Torbicz W. Immunosensors for human cardiac troponins and CRP, in particular amperometric cTnI immunosensor. Biocybern Biomed Eng 2016. [DOI: 10.1016/j.bbe.2015.11.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
10
|
Multi-color quantum dot-based fluorescence immunoassay array for simultaneous visual detection of multiple antibiotic residues in milk. Biosens Bioelectron 2015; 72:320-5. [DOI: 10.1016/j.bios.2015.05.018] [Citation(s) in RCA: 144] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Revised: 05/04/2015] [Accepted: 05/06/2015] [Indexed: 11/22/2022]
|
11
|
Simple and sensitive progesterone detection in human serum using a CdSe/ZnS quantum dot-based direct binding assay. Anal Biochem 2015; 483:54-61. [DOI: 10.1016/j.ab.2015.05.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 04/08/2015] [Accepted: 05/01/2015] [Indexed: 11/20/2022]
|
12
|
Lan T, Wang J, Dong C, Huang X, Ren J. Homogeneous immunoassays by using photon burst counting technique of single gold nanoparticles. Talanta 2015; 132:698-704. [DOI: 10.1016/j.talanta.2014.10.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2014] [Revised: 09/26/2014] [Accepted: 10/02/2014] [Indexed: 12/29/2022]
|
13
|
Synthesis and mechanism study of CdS quantum dots in two-phase liquid/liquid interfaces via one-pot route. Chem Phys Lett 2015. [DOI: 10.1016/j.cplett.2014.10.059] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
14
|
Wang H, Qi Y, Mountziaris TJ, Salthouse CD. A portable time-domain LED fluorimeter for nanosecond fluorescence lifetime measurements. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:055003. [PMID: 24880404 DOI: 10.1063/1.4873330] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Fluorescence lifetime measurements are becoming increasingly important in chemical and biological research. Time-domain lifetime measurements offer fluorescence multiplexing and improved handling of interferers compared with the frequency-domain technique. In this paper, an all solid-state, filterless, and highly portable light-emitting-diode based time-domain fluorimeter (LED TDF) is reported for the measurement of nanosecond fluorescence lifetimes. LED based excitation provides more wavelengths options compared to laser diode based excitation, but the excitation is less effective due to the uncollimated beam, less optical power, and longer latency in state transition. Pulse triggering and pre-bias techniques were implemented in our LED TDF to improve the peak optical power to over 100 mW. The proposed pulsing circuit achieved an excitation light fall time of less than 2 ns. Electrical resetting technique realized a time-gated photo-detector to remove the interference of the excitation light with fluorescence. These techniques allow the LED fluorimeter to accurately measure the fluorescence lifetime of fluorescein down to concentration of 0.5 μM. In addition, all filters required in traditional instruments are eliminated for the non-attenuated excitation/emission light power. These achievements make the reported device attractive to biochemical laboratories seeking for highly portable lifetime detection devices for developing sensors based on fluorescence lifetime changes. The device was initially validated by measuring the lifetimes of three commercial fluorophores and comparing them with reported lifetime data. It was subsequently used to characterize a ZnSe quantum dot based DNA sensor.
Collapse
Affiliation(s)
- Hongtao Wang
- Electrical and Computer Engineering Department, University of Massachusetts, Amherst, Massachusetts 01003, USA
| | - Ying Qi
- Center for Personalized Health Monitoring, University of Massachusetts, Amherst, Massachusetts 01003, USA
| | - T J Mountziaris
- Center for Personalized Health Monitoring, University of Massachusetts, Amherst, Massachusetts 01003, USA
| | - Christopher D Salthouse
- Electrical and Computer Engineering Department, University of Massachusetts, Amherst, Massachusetts 01003, USA
| |
Collapse
|
15
|
Kim CK, Duong HD, Rhee JI. Sequential injection immunoassay for human bone morphogenic protein-7 using an immunoreactor immobilized with anti-human bone morphogenic protein-7 antibody--CdSe/ZnS quantum dot conjugates. Anal Chim Acta 2013; 786:78-84. [PMID: 23790295 DOI: 10.1016/j.aca.2013.05.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2013] [Revised: 05/07/2013] [Accepted: 05/11/2013] [Indexed: 11/25/2022]
Abstract
The detection of human bone morphogenic protein-7 (BMP-7) was achieved using a sequential injection immunoassay (SIIA) system. The SIIA system is based on the binding between BMP-7 and anti-human BMP-7 (AbBMP7)-CdSe/ZnS quantum dot (QD) conjugates immobilized onto a glass disk or an optical fiber, using fluorescence detection at excitation and emission wavelengths of 470 nm and 580 nm, respectively. The AbBMP7-QD conjugates were prepared by conjugating anti-human BMP-7 antibody (AbBMP7) to hydrophilic CdSe/ZnS core/shell quantum dots (QDs). The SIIA system was fully automated using software written in the LabVIEW™ development environment. The analytical performance of the SIIA system was characterized with a number of variables such as carrier flow rate and elution buffer. Under partially optimized operating conditions, the SIIA system had a linear calibration graph at up to 10.0 ng mL(-1) BMP-7 (R(2)≥0.975) and a sample frequency of two samples per hour. The SIIA system with an optical fiber immunosensor was used to detect and quantify BMP-7 in spiked real samples obtained from a biological process with recoveries in the range of 95-102%.
Collapse
Affiliation(s)
- Chun-Kwang Kim
- School of Applied Chemical Engineering, Research Center for Biophotonics, Chonnam National University, YongBong-dong 300, GwangJu, Republic of Korea
| | | | | |
Collapse
|
16
|
Synergizing nucleic acid aptamers with 1-dimensional nanostructures as label-free field-effect transistor biosensors. Biosens Bioelectron 2013; 50:278-93. [PMID: 23872609 DOI: 10.1016/j.bios.2013.06.033] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2013] [Revised: 06/06/2013] [Accepted: 06/17/2013] [Indexed: 01/04/2023]
Abstract
Since the introduction by Gold et al. in 1990, nucleic acid aptamers had evolved to become a true contender in biosensors for protein and cell detections. Aptamers are short strands of synthetically designed DNA or RNA oligonucleotides that can be self-assembled into unique 3-dimensional structures and can bind to different proteins, cells or even small molecules at a high level of specificity and affinity. In recent years, there had been many reports in literature in using aptamers in place of conventional antibodies as capture biomolecules on the surface. This is mainly due to the better thermal stability properties and ease in production. Consequently, also these characteristics allowed the aptamers to find use in field effect transistors (FETs) based upon 1D nanostructured (1D-NS) as label-free biosensing. In terms of designing label-free platforms for biosensors applications, 1D-NS FET had been an attractive option due to reported high sensitivities toward protein targets arising from the large surface area for detection as well as to their label-free nature. Since the first aptamer-based 1D-NS FET biosensor had surfaced in 2005, there had been many more improvements in the overall design and sensitivity in recent years. In this review, the latest developments in synergizing these two interesting areas of research (aptamers and 1D-NS FET) will be discussed for a range of different nanowire types as well as for the detection results.
Collapse
|
17
|
An ultrasensitive electrochemiluminescent immunoassay for aflatoxin M1 in milk, based on extraction by magnetic graphene and detection by antibody-labeled CdTe quantumn dots-carbon nanotubes nanocomposite. Toxins (Basel) 2013; 5:865-83. [PMID: 23628784 PMCID: PMC3709266 DOI: 10.3390/toxins5050865] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Revised: 04/15/2013] [Accepted: 04/16/2013] [Indexed: 12/02/2022] Open
Abstract
An ultrasensitive electrochemiluminescent immunoassay (ECLIA) for aflatoxins M1 (ATM1) in milk using magnetic Fe3O4-graphene oxides (Fe-GO) as the absorbent and antibody-labeled cadmium telluride quantum dots (CdTe QDs) as the signal tag is presented. Firstly, Fe3O4 nanoparticles were immobilized on GO to fabricate the magnetic nanocomposites, which were used as absorbent to ATM1. Secondly, aflatoxin M1 antibody (primary antibody, ATM1 Ab1), was attached to the surface of the CdTe QDs-carbon nanotubes nanocomposite to form the signal tag (ATM1 Ab1/CdTe-CNT). The above materials were characterized. The optimal experimental conditions were obtained. Thirdly, Fe-GO was employed for extraction of ATM1 in milk. Results indicated that it can adsorb ATM1 efficiently and selectively within a large extent of pH from 3.0 to 8.0. Adsorption processes reached 95% of the equilibrium within 10 min. Lastly, the ATM1 with a serial of concentrations absorbed on Fe-GO was conjugated with ATM1 Ab1/CdTe-CNT signal tag based on sandwich immunoassay. The immunocomplex can emit a strong ECL signal whose intensity depended linearly on the logarithm of ATM1 concentration from 1.0 to 1.0 × 105 pg/mL, with the detection limit (LOD) of 0.3 pg/mL (S/N = 3). The method was more sensitive for ATM1 detection compared to the ELISA method. Finally, ten samples of milk were tested based on the immunoassay. The method is fast and requires very little sample preparation, which was suitable for high-throughput screening of mycotoxins in food.
Collapse
|