1
|
Su Y, Xia C, Zhang H, Gan W, Zhang GQ, Yang Z, Li D. Emerging biosensor probes for glycated hemoglobin (HbA1c) detection. Mikrochim Acta 2024; 191:300. [PMID: 38709399 DOI: 10.1007/s00604-024-06380-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 04/22/2024] [Indexed: 05/07/2024]
Abstract
Glycated hemoglobin (HbA1c), originating from the non-enzymatic glycosylation of βVal1 residues in hemoglobin (Hb), is an essential biomarker indicating average blood glucose levels over a period of 2 to 3 months without external environmental disturbances, thereby serving as the gold standard in the management of diabetes instead of blood glucose testing. The emergence of HbA1c biosensors presents affordable, readily available options for glycemic monitoring, offering significant benefits to small-scale laboratories and clinics. Utilizing nanomaterials coupled with high-specificity probes as integral components for recognition, labeling, and signal transduction, these sensors demonstrate exceptional sensitivity and selectivity in HbA1c detection. This review mainly focuses on the emerging probes and strategies integral to HbA1c sensor development. We discussed the advantages and limitations of various probes in sensor construction as well as recent advances in diverse sensing strategies for HbA1c measurement and their potential clinical applications, highlighting the critical gaps in current technologies and future needs in this evolving field.
Collapse
Affiliation(s)
- Yang Su
- Key Laboratory of DrugTargeting and Drug Delivery System of the Education Ministry and Sichuan Province, Sichuan Engineering Laboratory for Plant-Sourced Drug and Sichuan Research Center for Drug Precision Industrial Technology, West China School of Pharmacy, Sichuan University, Chengdu, 610041, China
| | - Chengen Xia
- Key Laboratory of DrugTargeting and Drug Delivery System of the Education Ministry and Sichuan Province, Sichuan Engineering Laboratory for Plant-Sourced Drug and Sichuan Research Center for Drug Precision Industrial Technology, West China School of Pharmacy, Sichuan University, Chengdu, 610041, China
| | - He Zhang
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Wei Gan
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Guo-Qi Zhang
- Department of Chemistry, School of Science, Xihua University, Chengdu, 610039, People's Republic of China
| | - Zi Yang
- Key Laboratory of DrugTargeting and Drug Delivery System of the Education Ministry and Sichuan Province, Sichuan Engineering Laboratory for Plant-Sourced Drug and Sichuan Research Center for Drug Precision Industrial Technology, West China School of Pharmacy, Sichuan University, Chengdu, 610041, China
| | - Dapeng Li
- Key Laboratory of DrugTargeting and Drug Delivery System of the Education Ministry and Sichuan Province, Sichuan Engineering Laboratory for Plant-Sourced Drug and Sichuan Research Center for Drug Precision Industrial Technology, West China School of Pharmacy, Sichuan University, Chengdu, 610041, China.
| |
Collapse
|
2
|
Yang Y, Dong H, Yin H, Gu J, Zhang Y, Xu M, Wang X, Zhou Y. Controllable preparation of silver-doped hollow carbon spheres and its application as electrochemical probes for determination of glycated hemoglobin. Bioelectrochemistry 2023; 152:108450. [PMID: 37116231 DOI: 10.1016/j.bioelechem.2023.108450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 04/17/2023] [Accepted: 04/19/2023] [Indexed: 04/30/2023]
Abstract
Silver-doped hollow carbon spheres (Ag@HCS) were firstly introduced as electrochemical probes for glycated hemoglobin (HbA1c) sensing at a molecularly imprinted polymer (MIP)-based carbon cloth (CC) electrode. Herein, Ag@HCS was prepared using one-pot polymerization of resorcinol and formaldehyde with AgNO3 on the SiO2 template, subsequent carbonization, and template removal. Furthermore, poly-aminophenylboronic acid (PABA) as the MIP film was used as a sensing platform for recognition of HbA1c, which captured the Ag@HCS probe by binding of HbA1c with aptamer modified on the probe surface. Due to regular geometry, large specific surface area, superior electrical conductivity, and highly-dispersed Ag, the prepared Ag@HCS probe provided an amplified electrochemical signal based on the Ag oxidation. By use of the sandwich-type electrochemical sensor, the ultrahigh sensitivity of 4.365 μA (μg mL-1)-1 cm-2 and a wide detection range of 0.8-78.4 μg mL-1 for HbA1c detection with a low detection limit of 0.35 μg mL-1 were obtained. Excellent selectivity was obtained due to the specific binding between HbA1c and PABA-based MIP film. The fabricated electrochemical sensing platform was also implemented successfully for the determination of HbA1c concentrations in the serum of healthy individuals.
Collapse
Affiliation(s)
- Yujie Yang
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China; School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007, China
| | - Hui Dong
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China
| | - Hewen Yin
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China; School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007, China
| | - Jie Gu
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China
| | - Yintang Zhang
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China
| | - Maotian Xu
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China
| | - Xiaobing Wang
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007, China
| | - Yanli Zhou
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, China; School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007, China.
| |
Collapse
|
3
|
Mandali PK, Prabakaran A, Annadurai K, Krishnan UM. Trends in Quantification of HbA1c Using Electrochemical and Point-of-Care Analyzers. SENSORS (BASEL, SWITZERLAND) 2023; 23:1901. [PMID: 36850502 PMCID: PMC9965793 DOI: 10.3390/s23041901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2023] [Revised: 01/30/2023] [Accepted: 02/03/2023] [Indexed: 06/18/2023]
Abstract
Glycated hemoglobin (HbA1c), one of the many variants of hemoglobin (Hb), serves as a standard biomarker of diabetes, as it assesses the long-term glycemic status of the individual for the previous 90-120 days. HbA1c levels in blood are stable and do not fluctuate when compared to the random blood glucose levels. The normal level of HbA1c is 4-6.0%, while concentrations > 6.5% denote diabetes. Conventionally, HbA1c is measured using techniques such as chromatography, spectroscopy, immunoassays, capillary electrophoresis, fluorometry, etc., that are time-consuming, expensive, and involve complex procedures and skilled personnel. These limitations have spurred development of sensors incorporating nanostructured materials that can aid in specific and accurate quantification of HbA1c. Various chemical and biological sensing elements with and without nanoparticle interfaces have been explored for HbA1c detection. Attempts are underway to improve the detection speed, increase accuracy, and reduce sample volumes and detection costs through different combinations of nanomaterials, interfaces, capture elements, and measurement techniques. This review elaborates on the recent advances in the realm of electrochemical detection for HbA1c detection. It also discusses the emerging trends and challenges in the fabrication of effective, accurate, and cost-effective point-of-care (PoC) devices for HbA1c and the potential way forward.
Collapse
Affiliation(s)
- Pavan Kumar Mandali
- Centre for Nanotechnology& Advanced Biomaterials, SASTRA Deemed University, Thanjavur 613 401, India
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur 613 401, India
| | - Amrish Prabakaran
- Centre for Nanotechnology& Advanced Biomaterials, SASTRA Deemed University, Thanjavur 613 401, India
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur 613 401, India
| | - Kasthuri Annadurai
- Centre for Nanotechnology& Advanced Biomaterials, SASTRA Deemed University, Thanjavur 613 401, India
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur 613 401, India
- School of Arts, Sciences, Humanities & Education, SASTRA Deemed University, Thanjavur 613 401, India
| | - Uma Maheswari Krishnan
- Centre for Nanotechnology& Advanced Biomaterials, SASTRA Deemed University, Thanjavur 613 401, India
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur 613 401, India
- School of Arts, Sciences, Humanities & Education, SASTRA Deemed University, Thanjavur 613 401, India
| |
Collapse
|
4
|
Zhao Y, Zhang H, Li Y, Wang X, Zhao L, Xu J, Zhan Z, Zhang G, Li WJ. Glycated Hemoglobin Electrochemical Immunosensor Based on Screen-Printed Electrode. BIOSENSORS 2022; 12:902. [PMID: 36291040 PMCID: PMC9599171 DOI: 10.3390/bios12100902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/04/2022] [Accepted: 10/10/2022] [Indexed: 06/16/2023]
Abstract
An electrochemical HbA1c sensor with high sensitivity and good specificity is proposed based on the electrochemical immune principle. The reproducibility and conductivity of the electrode are improved by depositing gold nanoparticles (AuNPs) on the surface of the screen-printed electrode (SPE). The HbA1c antibodies are immobilized on the surface of the modified electrode by adsorption to capture the HbA1c in the sample. The hindering effect of HbA1c on the electrode transfer reaction was exploited as the HbA1c detection mechanism. The electrode's properties were characterized by electrochemical impedance spectroscopy (EIS), and the measurement properties of the electrode were analyzed using differential pulse voltammetry (DPV) and cyclic voltammetry (CV). The experimental results show that the peak current signal of the electrochemical immunosensor produced a linear response to HbA1c in the concentration range of 20-200 μg/mL, a linear relationship coefficient of 0.9812, a detection limit of 15.5 µg/mL, and a sensitivity of 0.0938 µA/µg·mL-1. The sensor delivered satisfactory repeatability, stability, and anti-interference performance. Due to its small size, high sensitivity, and wide linear detection range, it is expected to play a significant role in managing diabetes at home.
Collapse
Affiliation(s)
- Yuliang Zhao
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China
| | - Hongyu Zhang
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong SAR 999077, China
| | - Yang Li
- Key Laboratory of Intelligent Rehabilitation and Neuromodulation of Hebei Province, School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China
| | - Xiaoai Wang
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China
| | - Liang Zhao
- Dalian Institute of Measurement and Testing, Dalian 116033, China
| | - Jianghong Xu
- Qinhuangdao Hospital of Traditional Chinese Medicine, Qinhuangdao 066004, China
| | - Zhikun Zhan
- Key Laboratory of Intelligent Rehabilitation and Neuromodulation of Hebei Province, School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China
- School of Computer and Communication Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China
| | - Guanglie Zhang
- City University of Hong Kong Shenzhen Research Institute, Shenzhen 518057, China
| | - Wen Jung Li
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong SAR 999077, China
| |
Collapse
|
5
|
Zhan Z, Li Y, Zhao Y, Zhang H, Wang Z, Fu B, Li WJ. A Review of Electrochemical Sensors for the Detection of Glycated Hemoglobin. BIOSENSORS 2022; 12:bios12040221. [PMID: 35448281 PMCID: PMC9024622 DOI: 10.3390/bios12040221] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 03/29/2022] [Accepted: 03/29/2022] [Indexed: 05/17/2023]
Abstract
Glycated hemoglobin (HbA1c) is the gold standard for measuring glucose levels in the diagnosis of diabetes due to the excellent stability and reliability of this biomarker. HbA1c is a stable glycated protein formed by the reaction of glucose with hemoglobin (Hb) in red blood cells, which reflects average glucose levels over a period of two to three months without suffering from the disturbance of the outside environment. A number of simple, high-efficiency, and sensitive electrochemical sensors have been developed for the detection of HbA1c. This review aims to highlight current methods and trends in electrochemistry for HbA1c monitoring. The target analytes of electrochemical HbA1c sensors are usually HbA1c or fructosyl valine/fructosyl valine histidine (FV/FVH, the hydrolyzed product of HbA1c). When HbA1c is the target analyte, a sensor works to selectively bind to specific HbA1c regions and then determines the concentration of HbA1c through the quantitative transformation of weak electrical signals such as current, potential, and impedance. When FV/FVH is the target analyte, a sensor is used to indirectly determine HbA1c by detecting FV/FVH when it is hydrolyzed by fructosyl amino acid oxidase (FAO), fructosyl peptide oxidase (FPOX), or a molecularly imprinted catalyst (MIC). Then, a current proportional to the concentration of HbA1c can be produced. In this paper, we review a variety of representative electrochemical HbA1c sensors developed in recent years and elaborate on their operational principles, performance, and promising future clinical applications.
Collapse
Affiliation(s)
- Zhikun Zhan
- School of Computer and Communication Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China;
- Key Laboratory of Intelligent Rehabilitation and Neuromodulation of Hebei Province, School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China; (Y.L.); (Z.W.); (B.F.)
| | - Yang Li
- Key Laboratory of Intelligent Rehabilitation and Neuromodulation of Hebei Province, School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China; (Y.L.); (Z.W.); (B.F.)
| | - Yuliang Zhao
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China
- Correspondence: (Y.Z.); (W.J.L.)
| | - Hongyu Zhang
- Department of Mechanical Engineering, City University of Hong Kong, Kowloon, Hong Kong 999077, China;
| | - Zhen Wang
- Key Laboratory of Intelligent Rehabilitation and Neuromodulation of Hebei Province, School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China; (Y.L.); (Z.W.); (B.F.)
| | - Boya Fu
- Key Laboratory of Intelligent Rehabilitation and Neuromodulation of Hebei Province, School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China; (Y.L.); (Z.W.); (B.F.)
| | - Wen Jung Li
- Department of Mechanical Engineering, City University of Hong Kong, Kowloon, Hong Kong 999077, China;
- Correspondence: (Y.Z.); (W.J.L.)
| |
Collapse
|
6
|
Shih HJ, Chen KC. An Analytical Energy Harvester Model for Interdigitated Ring Electrode on Circular Elastic Membrane. MICROMACHINES 2022; 13:mi13010133. [PMID: 35056298 PMCID: PMC8781394 DOI: 10.3390/mi13010133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 01/06/2022] [Accepted: 01/13/2022] [Indexed: 12/02/2022]
Abstract
Energy harvesters are devices that accumulate ambient vibrational energy from the environment, and for the time being, variable capacitance is the most widely used mechanism. Various designs were proposed to increase the power of such devices, and in particular, the interdigitated electrode (IDE) pattern is the mainstream. Nevertheless, most IDE designs focus merely on the parallel-type vibrations of electrodes. In this study, the performance of a novel harvester, which combined circular membrane and interdigitated ring electrodes (IRE), was investigated. This design allows the device to collect energy from the rotational structure motions of electrodes through the vibrating membrane. Besides, the circular structure provides a dense capacitive arrangement that is higher than that of the arrangement obtained using regular rectangular chips. The IRE diagram is composed of many capacitive rings, each of which harvests vibrated energy simultaneously. Three gaps (1, 10, and 100 μm) of the ring are investigated for the first four vibrational modes of the membrane to understand the effect of energy output. It is found that the energy outputs are approximately the same for the three gaps; however, rings with a wider gap are easier to manufacture in MEMS.
Collapse
|
7
|
Huang Y, Cohen TA, Sperry BM, Larson H, Nguyen HA, Homer MK, Dou FY, Jacoby LM, Cossairt BM, Gamelin DR, Luscombe CK. Organic building blocks at inorganic nanomaterial interfaces. MATERIALS HORIZONS 2022; 9:61-87. [PMID: 34851347 DOI: 10.1039/d1mh01294k] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
This tutorial review presents our perspective on designing organic molecules for the functionalization of inorganic nanomaterial surfaces, through the model of an "anchor-functionality" paradigm. This "anchor-functionality" paradigm is a streamlined design strategy developed from a comprehensive range of materials (e.g., lead halide perovskites, II-VI semiconductors, III-V semiconductors, metal oxides, diamonds, carbon dots, silicon, etc.) and applications (e.g., light-emitting diodes, photovoltaics, lasers, photonic cavities, photocatalysis, fluorescence imaging, photo dynamic therapy, drug delivery, etc.). The structure of this organic interface modifier comprises two key components: anchor groups binding to inorganic surfaces and functional groups that optimize their performance in specific applications. To help readers better understand and utilize this approach, the roles of different anchor groups and different functional groups are discussed and explained through their interactions with inorganic materials and external environments.
Collapse
Affiliation(s)
- Yunping Huang
- Department of Materials Science & Engineering, University of Washington, Seattle, WA 98195, USA.
| | - Theodore A Cohen
- Molecular Engineering & Sciences Institute, University of Washington, Seattle, WA 98195, USA
| | - Breena M Sperry
- Department of Materials Science & Engineering, University of Washington, Seattle, WA 98195, USA.
| | - Helen Larson
- Department of Chemistry, University of Washington, Seattle, WA 98195, USA
| | - Hao A Nguyen
- Department of Chemistry, University of Washington, Seattle, WA 98195, USA
| | - Micaela K Homer
- Department of Chemistry, University of Washington, Seattle, WA 98195, USA
| | - Florence Y Dou
- Department of Chemistry, University of Washington, Seattle, WA 98195, USA
| | - Laura M Jacoby
- Department of Chemistry, University of Washington, Seattle, WA 98195, USA
| | - Brandi M Cossairt
- Department of Chemistry, University of Washington, Seattle, WA 98195, USA
| | - Daniel R Gamelin
- Department of Chemistry, University of Washington, Seattle, WA 98195, USA
| | - Christine K Luscombe
- Department of Materials Science & Engineering, University of Washington, Seattle, WA 98195, USA.
- Molecular Engineering & Sciences Institute, University of Washington, Seattle, WA 98195, USA
- Department of Chemistry, University of Washington, Seattle, WA 98195, USA
| |
Collapse
|
8
|
Shajaripour Jaberi SY, Ghaffarinejad A, Omidinia E. An electrochemical paper based nano-genosensor modified with reduced graphene oxide-gold nanostructure for determination of glycated hemoglobin in blood. Anal Chim Acta 2019; 1078:42-52. [PMID: 31358227 DOI: 10.1016/j.aca.2019.06.018] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 06/04/2019] [Accepted: 06/10/2019] [Indexed: 01/02/2023]
Abstract
Hemoglobin A1c (HbA1c) is a standard biomarker to measure long-term average glucose concentration for diagnosis and monitoring of diabetes. Various methods have been reported for measuring HbA1c, however, portable and precise determination is still challenging. Herein, a new highly sensitive electrochemical nanobiosensor is developed for the specific determination of HbA1c. A nanocomposite of reduced graphene oxide (rGO) and gold with hierarchical architecture structure was electrochemically deposited on a cheap and flexible graphite sheet (GS) electrode. The nanocomposite increased the surface area, improved the electron transfer on the electrode surface and augmented the signal. It also provided a suitable substrate for linkage of thiolated DNA aptamer as a bioreceptor on the electrode surface by strong covalent bonding. The quantitative label free detection was carried out by differential pulse voltammetry (DPV) in a phosphate-buffered saline (PBS) solution containing redox probe Fe(CN)63-/4-. The detection is based on insulating the surface in presence of HbA1c and decreasing the current, which is directly related to the HbA1c concentration. The nanobiosensor demonstrated high sensitivity of 269.2 μA. cm-2, wide linear range of 1 nM-13.83 μM with a low detection limit of 1 nM. The biosensor was successfully used for measuring HbA1c in blood real sample. Furthermore, it is promising to use it as a part of a point of care device for low-invasive screening and management of diabetes.
Collapse
Affiliation(s)
- Seyedeh Yasaman Shajaripour Jaberi
- Research Laboratory of Real Samples Analysis, Faculty of Chemistry, Iran University of Science and Technology (IUST), Tehran, 1684613114, Iran; Electroanalytical Chemistry Research Center, Iran University of Science and Technology (IUST), Tehran, 1684613114, Iran
| | - Ali Ghaffarinejad
- Research Laboratory of Real Samples Analysis, Faculty of Chemistry, Iran University of Science and Technology (IUST), Tehran, 1684613114, Iran; Electroanalytical Chemistry Research Center, Iran University of Science and Technology (IUST), Tehran, 1684613114, Iran.
| | - Eskandar Omidinia
- Department of Biochemistry, Genetic and Metabolism Research Group, Pasteur Institute of Iran, Tehran, Iran.
| |
Collapse
|
9
|
Kaur J, Jiang C, Liu G. Different strategies for detection of HbA1c emphasizing on biosensors and point-of-care analyzers. Biosens Bioelectron 2018; 123:85-100. [PMID: 29903690 DOI: 10.1016/j.bios.2018.06.018] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Revised: 05/23/2018] [Accepted: 06/06/2018] [Indexed: 12/21/2022]
Abstract
Measurement of glycosylated hemoglobin (HbA1c) is a gold standard procedure for assessing long term glycemic control in individuals with diabetes mellitus as it gives the stable and reliable value of blood glucose levels for a period of 90-120 days. HbA1c is formed by the non-enzymatic glycation of terminal valine of hemoglobin. The analysis of HbA1c tends to be complicated because there are more than 300 different assay methods for measuring HbA1c which leads to variations in reported values from same samples. Therefore, standardization of detection methods is recommended. The review outlines the current research activities on developing assays including biosensors for the detection of HbA1c. The pros and cons of different techniques for measuring HbA1c are outlined. The performance of current point-of-care HbA1c analyzers available on the market are also compared and discussed. The future perspectives for HbA1c detection and diabetes management are proposed.
Collapse
Affiliation(s)
- Jagjit Kaur
- Graduate School of Biomedical Engineering, ARC Centre of Excellence in Nanoscale Biophotonics (CNBP), Faculty of Engineering, The University of New South Wales, Sydney 2052, Australia; Australian Centre for NanoMedicine, The University of New South Wales, Sydney 2052, Australia
| | - Cheng Jiang
- Nuffield Department of Clinical Neurosciences, Department of Chemistry, University of Oxford, Oxford OX1 2JD, United Kingdom
| | - Guozhen Liu
- Graduate School of Biomedical Engineering, ARC Centre of Excellence in Nanoscale Biophotonics (CNBP), Faculty of Engineering, The University of New South Wales, Sydney 2052, Australia; Australian Centre for NanoMedicine, The University of New South Wales, Sydney 2052, Australia; International Joint Research Center for Intelligent Biosensor Technology and Health, Central China Normal University, Wuhan 430079, PR China.
| |
Collapse
|
10
|
Tsai SA, Tang JY, Wang MH, Jang LS. Impedance measurement system for automatic determination of glycated hemoglobin. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:065003. [PMID: 29960512 DOI: 10.1063/1.5025151] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In this study, an automatic glycated hemoglobin (HbA1c) impedance measurement system (AHMS) is developed for the detection of HbA1c. The proposed device removes some of the drawbacks of common instruments for HbA1c detection (i.e., large, expensive, difficult to operate) by detecting the ratio of HbA1c to Hb. The method is label-free and requires only a small sample volume; no additional reagents are required. The manpower consumption and bulk of the instrument are also reduced. The method provides a simple way to analyze impedance deviation and effectively reduces the effort required by the operator. The ratios of HbA1c to Hb (4%-7%) are well distinguished, and the experiment is used to build a database for AHMS. To check the reliability of the proposed system, a sample test using three different ratios of HbA1c is applied in this study. The sample test uses HbA1c to Hb ratios of 4.7%, 5.6%, and 6.8%, and the determined experimental values are 4.93%, 5.8%, and 6.83%, respectively. The sample test has an accuracy of approximately 96.99%. Based on these results, the proposed system for detecting HbA1c through protein coverage is both effective and feasible.
Collapse
Affiliation(s)
- Shou-Ai Tsai
- Department of Electrical Engineering, National Cheng Kung University, 1 University Road, Tainan City 701, Taiwan
| | - Jing-Yau Tang
- Department of Electrical Engineering, National Cheng Kung University, 1 University Road, Tainan City 701, Taiwan
| | - Min-Haw Wang
- Department of Electrical Engineering, Chinese Culture University, Taipei City, Taiwan
| | - Ling-Sheng Jang
- Department of Electrical Engineering, National Cheng Kung University, 1 University Road, Tainan City 701, Taiwan
| |
Collapse
|
11
|
Current Status of HbA1c Biosensors. SENSORS 2017; 17:s17081798. [PMID: 28777351 PMCID: PMC5579747 DOI: 10.3390/s17081798] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2017] [Revised: 07/24/2017] [Accepted: 08/01/2017] [Indexed: 01/08/2023]
Abstract
Glycated hemoglobin (HbA1c) is formed via non-enzymatic glycosylation reactions at the α–amino group of βVal1 residues in the tetrameric Hb, and it can reflect the ambient glycemic level over the past two to three months. A variety of HbA1c detection methods, including chromatography, immunoassay, enzymatic measurement, electrochemical sensor and capillary electrophoresis have been developed and used in research laboratories and in clinics as well. In this review, we summarize the current status of HbA1c biosensors based on the recognition of the sugar moiety on the protein and also their applications in the whole blood sample measurements.
Collapse
|
12
|
|
13
|
Akiba U, Anzai JI. Recent Progress in Electrochemical Biosensors for Glycoproteins. SENSORS (BASEL, SWITZERLAND) 2016; 16:E2045. [PMID: 27916961 PMCID: PMC5191026 DOI: 10.3390/s16122045] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 11/22/2016] [Accepted: 11/29/2016] [Indexed: 12/20/2022]
Abstract
This review provides an overview of recent progress in the development of electrochemical biosensors for glycoproteins. Electrochemical glycoprotein sensors are constructed by combining metal and carbon electrodes with glycoprotein-selective binding elements including antibodies, lectin, phenylboronic acid and molecularly imprinted polymers. A recent trend in the preparation of glycoprotein sensors is the successful use of nanomaterials such as graphene, carbon nanotube, and metal nanoparticles. These nanomaterials are extremely useful for improving the sensitivity of glycoprotein sensors. This review focuses mainly on the protocols for the preparation of glycoprotein sensors and the materials used. Recent improvements in glycoprotein sensors are discussed by grouping the sensors into several categories based on the materials used as recognition elements.
Collapse
Affiliation(s)
- Uichi Akiba
- Graduate School of Engineering and Science, Akita University, 1-1 Tegatagaluenn-machi, Akita 010-8502, Japan.
| | - Jun-Ichi Anzai
- Graduate School of Pharmaceutical Sciences, Tohoku University, Aoba, Aramakim, Sendai 980-8578, Japan.
| |
Collapse
|
14
|
Boonyasit Y, Laiwattanapaisal W, Chailapakul O, Emnéus J, Heiskanen AR. Boronate-Modified Interdigitated Electrode Array for Selective Impedance-Based Sensing of Glycated Hemoglobin. Anal Chem 2016; 88:9582-9589. [DOI: 10.1021/acs.analchem.6b02234] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Yuwadee Boonyasit
- Graduate
Program in Clinical Biochemistry and Molecular Medicine, Faculty of
Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
- Department
of Micro- and Nanotechnology, Technical University of Denmark, Kongens
Lyngby, 2800, Denmark
| | - Wanida Laiwattanapaisal
- Department
of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Orawon Chailapakul
- Electrochemistry
and Optical Spectroscopy Research Unit (EOSRU), Department of Chemistry,
Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Jenny Emnéus
- Department
of Micro- and Nanotechnology, Technical University of Denmark, Kongens
Lyngby, 2800, Denmark
| | - Arto R. Heiskanen
- Department
of Micro- and Nanotechnology, Technical University of Denmark, Kongens
Lyngby, 2800, Denmark
- Department
of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
| |
Collapse
|
15
|
Boonyasit Y, Chailapakul O, Laiwattanapaisal W. A multiplexed three-dimensional paper-based electrochemical impedance device for simultaneous label-free affinity sensing of total and glycated haemoglobin: The potential of using a specific single-frequency value for analysis. Anal Chim Acta 2016; 936:1-11. [DOI: 10.1016/j.aca.2016.05.047] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Revised: 05/30/2016] [Accepted: 05/31/2016] [Indexed: 11/26/2022]
|
16
|
Sridevi S, Vasu KS, Sampath S, Asokan S, Sood AK. Optical detection of glucose and glycated hemoglobin using etched fiber Bragg gratings coated with functionalized reduced graphene oxide. JOURNAL OF BIOPHOTONICS 2016; 9:760-9. [PMID: 26266873 DOI: 10.1002/jbio.201580156] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2015] [Revised: 07/07/2015] [Accepted: 07/12/2015] [Indexed: 05/05/2023]
Abstract
An enhanced optical detection of D-glucose and glycated hemoglobin (HbA1c ) has been established in this study using etched fiber Bragg gratings (eFBG) coated with aminophenylboronic acid (APBA)-functionalized reduced graphene oxide (RGO). The read out, namely the shift in Bragg wavelength (ΔλB ) is highly sensitive to changes that occur due to the adsorption of glucose (or HbA1c ) molecules on the eFBG sensor coated with APBA-RGO complex through a five-membered cyclic ester bond formation between glucose and APBA molecules. A limit of detection of 1 nM is achieved with a linear range of detection from 1 nM to 10 mM in the case of D-glucose detection experiments. For HbA1c , a linear range of detection varying from 86 nM to 0.23 mM is achieved. The observation of only 4 pm (picometer) change in ΔλB even for the 10 mM lactose solution confirms the specificity of the APBA-RGO complex coated eFBG sensors to glucose molecules.
Collapse
Affiliation(s)
- S Sridevi
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, 560012, India
| | - K S Vasu
- Department of Physics, Indian Institute of Science, Bangalore, 560012, India
| | - S Sampath
- Department of Inorganic and Physical Chemistry, Indian Institute of Science, Bangalore, 560012, India
| | - S Asokan
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, 560012, India
- Robert Bosch Centre for Cyber Physical Systems, Indian Institute of Science, Bangalore, 560012, India
| | - A K Sood
- Department of Physics, Indian Institute of Science, Bangalore, 560012, India.
| |
Collapse
|
17
|
Ang SH, Rambeli M, Thevarajah TM, Alias YB, Khor SM. Quantitative, single-step dual measurement of hemoglobin A1c and total hemoglobin in human whole blood using a gold sandwich immunochromatographic assay for personalized medicine. Biosens Bioelectron 2016; 78:187-193. [DOI: 10.1016/j.bios.2015.11.045] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Revised: 11/13/2015] [Accepted: 11/14/2015] [Indexed: 11/30/2022]
|
18
|
A lateral flow immunosensor for direct, sensitive, and highly selective detection of hemoglobin A1c in whole blood. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1015-1016:157-165. [DOI: 10.1016/j.jchromb.2016.01.059] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Revised: 01/19/2016] [Accepted: 01/30/2016] [Indexed: 01/19/2023]
|
19
|
|
20
|
Huynh TP, Sharma PS, Sosnowska M, D'Souza F, Kutner W. Functionalized polythiophenes: Recognition materials for chemosensors and biosensors of superior sensitivity, selectivity, and detectability. Prog Polym Sci 2015. [DOI: 10.1016/j.progpolymsci.2015.04.009] [Citation(s) in RCA: 73] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
21
|
Boonyasit Y, Heiskanen A, Chailapakul O, Laiwattanapaisal W. Selective label-free electrochemical impedance measurement of glycated haemoglobin on 3-aminophenylboronic acid-modified eggshell membranes. Anal Bioanal Chem 2015; 407:5287-97. [PMID: 25956596 DOI: 10.1007/s00216-015-8680-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Revised: 03/31/2015] [Accepted: 04/07/2015] [Indexed: 02/02/2023]
Abstract
We propose a novel alternative approach to long-term glycaemic monitoring using eggshell membranes (ESMs) as a new immobilising platform for the selective label-free electrochemical sensing of glycated haemoglobin (HbA1c), a vital clinical index of the glycaemic status in diabetic individuals. Due to the unique features of a novel 3-aminophenylboronic acid-modified ESM, selective binding was obtained via cis-diol interactions. This newly developed device provides clinical applicability as an affinity membrane-based biosensor for the identification of HbA1c over a clinically relevant range (2.3 - 14 %) with a detection limit of 0.19%. The proposed membrane-based biosensor also exhibited good reproducibility. When analysing normal and abnormal HbA1c levels, the within-run coefficients of variation were 1.68 and 1.83%, respectively. The run-to-run coefficients of variation were 1.97 and 2.02%, respectively. These results demonstrated that this method achieved the precise and selective measurement of HbA1c. Compared with a commercial HbA1c kit, the results demonstrated excellent agreement between the techniques (n = 15), demonstrating the clinical applicability of this sensor for monitoring glycaemic control. Thus, this low-cost sensing platform using the proposed membrane-based biosensor is ideal for point-of-care diagnostics.
Collapse
Affiliation(s)
- Yuwadee Boonyasit
- Graduate Program in Clinical Biochemistry and Molecular Medicine, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
| | | | | | | |
Collapse
|
22
|
Ultrasensitive Impedimetric Biosensor Fabricated by a New Immobilisation Technique for Parathyroid Hormone. Appl Biochem Biotechnol 2015; 176:1251-62. [DOI: 10.1007/s12010-015-1643-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Accepted: 04/21/2015] [Indexed: 10/23/2022]
|
23
|
Wang B, Anzai JI. Recent Progress in Electrochemical HbA1c Sensors: A Review. MATERIALS (BASEL, SWITZERLAND) 2015; 8:1187-1203. [PMID: 28787996 PMCID: PMC5455452 DOI: 10.3390/ma8031187] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2015] [Revised: 03/04/2015] [Accepted: 03/04/2015] [Indexed: 11/18/2022]
Abstract
This article reviews recent progress made in the development of electrochemical glycated hemoglobin (HbA1c) sensors for the diagnosis and management of diabetes mellitus. Electrochemical HbA1c sensors are divided into two categories based on the detection protocol of the sensors. The first type of sensor directly detects HbA1c by binding HbA1c on the surface of an electrode through bio-affinity of antibody and boronic acids, followed by an appropriate mode of signal transduction. In the second type of sensor, HbA1c is indirectly determined by detecting a digestion product of HbA1c, fructosyl valine (FV). Thus, the former sensors rely on the selective binding of HbA1c to the surface of the electrodes followed by electrochemical signaling in amperometric, voltammetric, impedometric, or potentiometric mode. Redox active markers, such as ferrocene derivatives and ferricyanide/ferrocyanide ions, are often used for electrochemical signaling. For the latter sensors, HbA1c must be digested in advance by proteolytic enzymes to produce the FV fragment. FV is electrochemically detected through catalytic oxidation by fructosyl amine oxidase or by selective binding to imprinted polymers. The performance characteristics of HbA1c sensors are discussed in relation to their use in the diagnosis and control of diabetic mellitus.
Collapse
Affiliation(s)
- Baozhen Wang
- Department of Nutrition and Food Hygiene, School of Public Health, Shandong University, 44 Wenhuaxi Road, Jinan 250012, Shandong, China.
- Graduate School of Pharmaceutical Sciences, Tohoku University, Aramaki, Aoba-ku, Sendai 980-8578, Japan.
| | - Jun-Ichi Anzai
- Graduate School of Pharmaceutical Sciences, Tohoku University, Aramaki, Aoba-ku, Sendai 980-8578, Japan.
| |
Collapse
|
24
|
Özcan HM, Sezgintürk MK. Detection of parathyroid hormone using an electrochemical impedance biosensor based on PAMAM dendrimers. Biotechnol Prog 2015; 31:815-22. [DOI: 10.1002/btpr.2060] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Revised: 12/19/2014] [Indexed: 11/11/2022]
Affiliation(s)
- Hakkı Mevlüt Özcan
- Chemistry Dept., Faculty of Science, University of Trakya; Edirne Turkey
| | | |
Collapse
|
25
|
Using poly(3-aminophenylboronic acid) thin film with binding-induced ion flux blocking for amperometric detection of hemoglobin A1c. Biosens Bioelectron 2015; 63:317-324. [DOI: 10.1016/j.bios.2014.07.058] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Revised: 07/15/2014] [Accepted: 07/16/2014] [Indexed: 11/22/2022]
|
26
|
Ang SH, Thevarajah M, Alias Y, Khor SM. Current aspects in hemoglobin A1c detection: A review. Clin Chim Acta 2015; 439:202-11. [DOI: 10.1016/j.cca.2014.10.019] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2014] [Revised: 10/09/2014] [Accepted: 10/11/2014] [Indexed: 11/29/2022]
|
27
|
Lacina K, Skládal P, James TD. Boronic acids for sensing and other applications - a mini-review of papers published in 2013. Chem Cent J 2014; 8:60. [PMID: 25371705 PMCID: PMC4218984 DOI: 10.1186/s13065-014-0060-5] [Citation(s) in RCA: 88] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2014] [Accepted: 10/06/2014] [Indexed: 12/20/2022] Open
Abstract
Boronic acids are increasingly utilised in diverse areas of research. Including the interactions of boronic acids with diols and strong Lewis bases as fluoride or cyanide anions, which leads to their utility in various sensing applications. The sensing applications can be homogeneous assays or heterogeneous detection. Detection can be at the interface of the sensing material or within the bulk sample. Furthermore, the key interaction of boronic acids with diols allows utilisation in various areas ranging from biological labelling, protein manipulation and modification, separation and the development of therapeutics. All the above uses and applications are covered by this mini-review of papers published during 2013.
Collapse
Affiliation(s)
- Karel Lacina
- />CEITEC, Masaryk University, Kamenice 5, 62500 Brno, Czech Republic
- />Department of Chemistry, University of Bath, Claverton Down, Bath, BA2 7AY UK
| | - Petr Skládal
- />CEITEC, Masaryk University, Kamenice 5, 62500 Brno, Czech Republic
- />Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 62500 Brno, Czech Republic
| | - Tony D James
- />Department of Chemistry, University of Bath, Claverton Down, Bath, BA2 7AY UK
| |
Collapse
|
28
|
Electrochemical biosensors based on ferroceneboronic Acid and its derivatives: a review. BIOSENSORS-BASEL 2014; 4:243-56. [PMID: 25587421 PMCID: PMC4264357 DOI: 10.3390/bios4030243] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 07/03/2014] [Accepted: 07/25/2014] [Indexed: 11/16/2022]
Abstract
We review recent progress in the development of electrochemical biosensors based on ferroceneboronic acid (FcBA) and ferrocene (Fc)-modified boronic acids. These compounds can be used to construct electrochemical biosensors because they consist of a binding site (i.e., a boronic acid moiety) and an electrochemically active part (i.e., an Fc residue). By taking advantage of the unique properties of FcBA and its derivatives, electrochemical sensors sensitive to sugars, glycated hemoglobin (HbA1c), fluoride (F(-)) ions, and so forth have been widely studied. FcBA-based sugar sensors rely on the selective binding of FcBA to 1,2- or 1,3-diol residues of sugars through the formation of cyclic boronate ester bonds. The redox properties of FcBA-sugar adduct differ from those of free FcBA, which forms the basis of the electrochemical determination of sugars. Thus, non-enzymatic glucose sensors are now being actively studied using FcBA and Fc-modified boronic acids as redox markers. Using a similar principle, HbA1c can be detected by FcBA-based electrochemical systems because it contains hydrocarbon chains on the polypeptide chain. HbA1c sensors are useful for monitoring blood glucose levels over the preceding 8-12 weeks. In addition, FcBA and Fc-modified boronic acids have been used for the detection of F(-) ions due to the selective binding of boronic acid to F(-) ions. F(-)-ion sensors may be useful alternatives to conventional ion-selective electrodes sensitive to F(-) ion. Furthermore, FcBA derivatives have been studied to construct lectin; steroids; nucleotides; salicylic acid; and bacteria sensors. One of the limitations of FcBA-based sensors comes from the fact that FcBA derivatives are added in sample solutions as reagents. FcBA derivatives should be immobilized on the surface of electrodes for developing reagentless sensors.
Collapse
|