1
|
Ouedraogo SY, Zeye MMJ, Zhou X, Kiendrebeogo TI, Zoure AA, Chen H, Chen F, Ma C. Colorimetric detection of single-nucleotide mutations based on rolling circle amplification and G-quadruplex-based DNAzyme. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:5785-5792. [PMID: 39140250 DOI: 10.1039/d4ay01080a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/15/2024]
Abstract
In this work, we proposed a sensitive and selective colorimetric assay for single nucleotide mutation (SNM) detection combining rolling circle amplification (RCA) and G-quadruplex/hemin DNAzyme complex formation. In the detection principle, the first step involves ssDNA hybridization with a padlock probe (PLP) DNA, which can discriminate a single base mismatch. The successful ligation is followed by an RCA event to generate an abundance of G-quadruplexes (GQ-RCA) which are then transformed into a DNAzyme (G-quadruplex/hemin complex) by the addition of hemin. The color change from colorless 3,3',5,5'-tetramethylbenzidine (TMB) into colored oxTMB when hydrogen peroxide (H2O2) is added indicated the presence of a mutation. The assay had a limit of detection (LOD) of 2.14 pM. Mutations in samples from breast cancer patients were successfully detected with an accuracy of 100% when compared to Sanger sequencing results. The method is easily applicable even in resource poor setting regions given that it doesn't require any sophisticated or expensive instruments, and the signal readout is detectable simply by the naked eye. Our assay might be a useful tool for genetic analysis and clinical molecular diagnosis for breast cancer risk assessment and early detection.
Collapse
Affiliation(s)
- Serge Yannick Ouedraogo
- Department of Biochemistry and Molecular Biology, School of Life Sciences, Central South University, Changsha 410013, Hunan, China.
- Biomolecular Research Center Pietro Annigoni (CERBA), LABIOGENE, University of Ouaga 1 Pr Joseph KI ZERBO, UFR/SVT, Burkina Faso
| | - Moutanou Modeste Judes Zeye
- Department of Medical Parasitology, School of Basic Medicine, Central South University, Changsha 410013, Hunan, China
| | - Xi Zhou
- Department of Biochemistry and Molecular Biology, School of Life Sciences, Central South University, Changsha 410013, Hunan, China.
| | | | - Abdou Azaque Zoure
- Biomolecular Research Center Pietro Annigoni (CERBA), LABIOGENE, University of Ouaga 1 Pr Joseph KI ZERBO, UFR/SVT, Burkina Faso
- Department of Biomedical and Public Health, Institute of Health Sciences Research (IRSS/CNRST), Burkina Faso
| | - Hanchun Chen
- Department of Biochemistry and Molecular Biology, School of Life Sciences, Central South University, Changsha 410013, Hunan, China.
| | - Fangzhi Chen
- Department of Urology, The Second Xiangya Hospital of Central South University, Changsha 410007, Hunan, China.
| | - Changbei Ma
- Department of Biochemistry and Molecular Biology, School of Life Sciences, Central South University, Changsha 410013, Hunan, China.
| |
Collapse
|
2
|
Rösch EL, Sack R, Chowdhury MS, Wolgast F, Zaborski M, Ludwig F, Schilling M, Viereck T, Rand U, Lak A. Amplification- and Enzyme-Free Magnetic Diagnostics Circuit for Whole-Genome Detection of SARS-CoV-2 RNA. Chembiochem 2024; 25:e202400251. [PMID: 38709072 DOI: 10.1002/cbic.202400251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Revised: 04/30/2024] [Accepted: 05/06/2024] [Indexed: 05/07/2024]
Abstract
Polymerase chain reaction (PCR) requires thermal cycling and enzymatic reactions for sequence amplification, hampering their applications in point-of-care (POC) settings. Magnetic bioassays based on magnetic particle spectroscopy (MPS) and magnetic nanoparticles (MNPs) are isothermal, wash-free, and can be quantitative. Realizing them amplification- and enzyme-free on a benchtop device, they will become irreplaceable for POC applications. Here we demonstrate a first-in-class magnetic signal amplification circuit (MAC) that enables detection of whole genome of SARS-CoV-2 by combining the specificity of toehold-mediated DNA strand displacement with the magnetic response of MNPs to declustering processes. Using MAC, we detect the N gene of SARS-CoV-2 samples at a concentration of 104 RNA copies/μl as determined by droplet digital PCR. Further, we demonstrate that MAC can reliably distinguish between SARS-CoV-2 and other human coronaviruses. Being a wash-, amplification- and enzyme-free biosensing concept and working at isothermal conditions (25 °C) on a low-cost benchtop MPS device, our MAC biosensing concept offers several indispensable features for translating nucleic acid detection to POC applications.
Collapse
Affiliation(s)
- Enja Laureen Rösch
- Institute for Electrical Measurement Science and Fundamental Electrical Engineering and Laboratory for Emerging Nanometrology (LENA), Hans-Sommer-Str. 66, Braunschweig, 38106, Germany
| | - Rebecca Sack
- Institute for Electrical Measurement Science and Fundamental Electrical Engineering and Laboratory for Emerging Nanometrology (LENA), Hans-Sommer-Str. 66, Braunschweig, 38106, Germany
| | - Mohammad Suman Chowdhury
- Institute for Electrical Measurement Science and Fundamental Electrical Engineering and Laboratory for Emerging Nanometrology (LENA), Hans-Sommer-Str. 66, Braunschweig, 38106, Germany
| | - Florian Wolgast
- Institute for Electrical Measurement Science and Fundamental Electrical Engineering and Laboratory for Emerging Nanometrology (LENA), Hans-Sommer-Str. 66, Braunschweig, 38106, Germany
| | - Margarete Zaborski
- Leibniz Institute, German Collection of Microorganisms and Cell Cultures GmbH (DSMZ), Inhoffenstr. 7b, Braunschweig, 38124, Germany
| | - Frank Ludwig
- Institute for Electrical Measurement Science and Fundamental Electrical Engineering and Laboratory for Emerging Nanometrology (LENA), Hans-Sommer-Str. 66, Braunschweig, 38106, Germany
| | - Meinhard Schilling
- Institute for Electrical Measurement Science and Fundamental Electrical Engineering and Laboratory for Emerging Nanometrology (LENA), Hans-Sommer-Str. 66, Braunschweig, 38106, Germany
| | - Thilo Viereck
- Institute for Electrical Measurement Science and Fundamental Electrical Engineering and Laboratory for Emerging Nanometrology (LENA), Hans-Sommer-Str. 66, Braunschweig, 38106, Germany
| | - Ulfert Rand
- Leibniz Institute, German Collection of Microorganisms and Cell Cultures GmbH (DSMZ), Inhoffenstr. 7b, Braunschweig, 38124, Germany
| | - Aidin Lak
- Institute for Electrical Measurement Science and Fundamental Electrical Engineering and Laboratory for Emerging Nanometrology (LENA), Hans-Sommer-Str. 66, Braunschweig, 38106, Germany
| |
Collapse
|
3
|
Li T, Meng F, Fang Y, Luo Y, He Y, Dong Z, Tian B. Multienzymatic disintegration of DNA-scaffolded magnetic nanoparticle assembly for malarial mitochondrial DNA detection. Biosens Bioelectron 2024; 246:115910. [PMID: 38086308 DOI: 10.1016/j.bios.2023.115910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 11/20/2023] [Accepted: 12/02/2023] [Indexed: 12/30/2023]
Abstract
Early diagnosis of malaria can prevent the spread of disease and save lives, which, however, remains challenging in remote and less developed regions. Here we report a portable and low-cost optomagnetic biosensor for rapid amplification and detection of malarial mitochondrial DNA. Bioresponsive magnetic nanoparticle assemblies are constructed by using nucleic acid scaffolds containing endonucleolytic DNAzymes and their substrates, which can be activated by the presence of target DNA and self-disintegrated to release magnetic nanoparticles for optomagnetic quantification. Specifically, target molecules can induce padlock probe ligation and subsequent one-pot homogeneous cascade reactions consisting of nicking-enhanced rolling circle amplification, DNAzyme-assisted nucleic acid recycling, and strand-displacement-driven disintegration of the magnetic assembly. With an optimized magnetic actuation process for reaction acceleration, a detection limit of 1 fM can be achieved by the proposed biosensor with a total assay time of ca. 90 min and a dynamic detection range spanning 3 orders of magnitude. The robustness of the system was validated by testing target molecules spiked in 5% serum samples. Clinical sample validation was conducted by testing malaria-positive clinical blood specimens, obtaining quantitative results concordant with qPCR measurements.
Collapse
Affiliation(s)
- Tingting Li
- School of Basic Medical Sciences, Central South University, Changsha, 410013, China
| | - Fanming Meng
- School of Basic Medical Sciences, Central South University, Changsha, 410013, China; School of Basic Medical Sciences, Xinjiang Medical University, Urumqi, 830017, China
| | - Yuan Fang
- School of Basic Medical Sciences, Central South University, Changsha, 410013, China; College of Biology, Hunan University, Changsha, 410082, China
| | - Yifei Luo
- School of Basic Medical Sciences, Central South University, Changsha, 410013, China
| | - Yilong He
- School of Basic Medical Sciences, Central South University, Changsha, 410013, China
| | - Zhuxin Dong
- School of Basic Medical Sciences, Central South University, Changsha, 410013, China; Furong Laboratory, Changsha, 410008, China
| | - Bo Tian
- School of Basic Medical Sciences, Central South University, Changsha, 410013, China; Furong Laboratory, Changsha, 410008, China.
| |
Collapse
|
4
|
Sen S, Bhowmik P, Tiwari S, Peleg Y, Bandyopadhyay B. Versatility of reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) from diagnosis of early pathological infection to mutation detection in organisms. Mol Biol Rep 2024; 51:211. [PMID: 38270670 DOI: 10.1007/s11033-023-09110-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Accepted: 12/05/2023] [Indexed: 01/26/2024]
Abstract
Loop-mediated isothermal amplification (LAMP) is a rapid, state-of-the-art DNA amplification technology, used primarily for the quick diagnosis and early identification of microbial infection, caused by pathogens such as virus, bacteria and malaria. A target DNA can be amplified within 30 min using the LAMP reaction, taking place at a steady temperature. The LAMP method uses four or six primers to bind eight regions of a target DNA and has a very high specificity. The devices used for conducting LAMP are usually simple since the LAMP method is an isothermal process. When LAMP is coupled with Reverse Transcription (RT), it allows direct detection of RNA in a sample. This greatly enhances the efficiency of diagnosis of RNA viruses in a sample. Recently, the rampant spread of COVID-19 demanded such a rapid, simple, and cost-effective Point of Care Test (PoCT) for the accurate diagnosis of this pandemic. Loop-mediated isothermal amplification (LAMP) assays are not only used for the detection of microbial pathogens, but there are various other applications such as detection of genetic mutations in food and various organisms. In this review, various implementations of RT-LAMP techniques would be discussed.
Collapse
Affiliation(s)
- Srishti Sen
- School of Bioscience, Engineering and Technology, VIT Bhopal University, Bhopal, Madhya Pradesh, India
| | - Priyanka Bhowmik
- Department of Biological Sciences, School of Life Science and Biotechnology, Adamas University, Kolkata, India
| | - Shubhangi Tiwari
- School of Bioscience, Engineering and Technology, VIT Bhopal University, Bhopal, Madhya Pradesh, India
| | - Yoav Peleg
- Structural Proteomics Unit (SPU), Life Sciences Core Facilities (LSCF), Weizmann Institute of Science, Rehovot, Israel
| | - Boudhayan Bandyopadhyay
- Department of Biotechnology, School of Life Science and Biotechnology, Adamas University, Kolkata, India.
| |
Collapse
|
5
|
Dias BDP, Barbosa CC, Ferreira CS, Mayra Soares Alves Dos Santos S, Arrieta OAP, Malta WC, Gomes MLMD, Alves E Silva M, Fonseca JDM, Borges LP, Silva BDM. Challenges in Direct Detection of Flaviviruses: A Review. Pathogens 2023; 12:pathogens12050643. [PMID: 37242313 DOI: 10.3390/pathogens12050643] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 04/18/2023] [Accepted: 04/20/2023] [Indexed: 05/28/2023] Open
Abstract
Arthropods transmit arboviruses via mosquito and tick bites to humans and other animals. The genus flavivirus, which causes diseases, sequelae, and thousands of deaths, mainly in developing and underdeveloped countries, is among the arboviruses of interest to public health. Given the importance of early and accurate diagnosis, this review analyzes the methods of direct detection of flaviviruses, such as reverse transcription loop-mediated isothermal amplification, microfluidics, localized surface plasmon resonance, and surface-enhanced Raman scattering, and presents the advantages, disadvantages, and detection limits identified in studies reported in the literature for each methodology. Among the different methods available, it is essential to balance four fundamental indicators to determine the ideal test: good sensitivity, high specificity, low false positive rate, and rapid results. Among the methods analyzed, reverse transcription loop-mediated isothermal amplification stands out, owing to result availability within a few minutes, with good sensitivity and specificity; in addition, it is the best-characterized methodology.
Collapse
Affiliation(s)
- Bruna de Paula Dias
- Department of Biological Sciences, Federal University of Ouro Preto, Ouro Preto 35400-000, Brazil
| | - Camila Cavadas Barbosa
- Department of Biological Sciences, Federal University of Ouro Preto, Ouro Preto 35400-000, Brazil
| | - Cyntia Silva Ferreira
- Department of Biological Sciences, Federal University of Ouro Preto, Ouro Preto 35400-000, Brazil
| | | | | | | | | | - Mariela Alves E Silva
- Department of Biological Sciences, Federal University of Ouro Preto, Ouro Preto 35400-000, Brazil
| | - Júlia de Matos Fonseca
- Department of Biological Sciences, Federal University of Ouro Preto, Ouro Preto 35400-000, Brazil
| | - Lysandro Pinto Borges
- Department of Pharmacy, Federal University of Sergipe, São Cristóvão 9100-000, Brazil
| | - Breno de Mello Silva
- Department of Biological Sciences, Federal University of Ouro Preto, Ouro Preto 35400-000, Brazil
| |
Collapse
|
6
|
Kaarj K, Yoon JY. Loop-Mediated Isothermal Amplification on Paper Microfluidic Chips for Highly Sensitive and Specific Zika Virus Detection Using Smartphone. Methods Mol Biol 2023; 2621:307-323. [PMID: 37041453 DOI: 10.1007/978-1-0716-2950-5_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2023]
Abstract
Zika virus (ZIKV) infection may cause serious birth defects and is a critical concern for women of child-bearing age in affected regions. A simple, portable, and easy-to-use ZIKV detection method would enable point-of-care testing, which may aid in prevention of the spread of the virus. Herein, we describe a reverse transcription isothermal loop-mediated amplification (RT-LAMP) method that detects the presence of ZIKV RNA in complex samples (e.g., blood, urine, and tap water). Phenol red is the colorimetric indicator of successful amplification. Color changes based on the amplified RT-LAMP product from the presence of viral target are monitored using a smartphone camera under ambient light conditions. A single viral RNA molecule per μL can be detected in as quickly as 15 min using this method with 100% sensitivity and 100% specificity in blood and tap water, while 100% sensitivity and 67% specificity in urine. This platform can also be used to identify other viruses including SARS-CoV-2 and improve the current state of field-based diagnostics.
Collapse
Affiliation(s)
- Kattika Kaarj
- School of Biology, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, Thailand
| | - Jeong-Yeol Yoon
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, USA.
| |
Collapse
|
7
|
Park JW. Principles and Applications of Loop-Mediated Isothermal Amplification to Point-of-Care Tests. BIOSENSORS 2022; 12:bios12100857. [PMID: 36290994 PMCID: PMC9599884 DOI: 10.3390/bios12100857] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 09/30/2022] [Accepted: 10/08/2022] [Indexed: 05/03/2023]
Abstract
For the identification of nucleic acids, which are important biomarkers of pathogen-mediated diseases and viruses, the gold standard for NA-based diagnostic applications is polymerase chain reaction (PCR). However, the requirements of PCR limit its application as a rapid point-of-care diagnostic technique. To address the challenges associated with regular PCR, many isothermal amplification methods have been developed to accurately detect NAs. Isothermal amplification methods enable NA amplification without changes in temperature with simple devices, as well as faster amplification times compared with regular PCR. Of the isothermal amplifications, loop-mediated isothermal amplification (LAMP) is the most studied because it amplifies NAs rapidly and specifically. This review describes the principles of LAMP, the methods used to monitor the process of LAMP, and examples of biosensors that detect the amplicons of LAMP. In addition, current trends in the application of LAMP to smartphones and self-diagnosis systems for point-of-care tests are also discussed.
Collapse
Affiliation(s)
- Jee-Woong Park
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation (K-MEDI Hub), Daegu 41061, Korea
| |
Collapse
|
8
|
Siriyasatien P, Wacharapluesadee S, Kraivichian K, Suwanbamrung C, Sutthanont N, Cantos-Barreda A, Phumee A. Development and evaluation of a visible reverse transcription-loop-mediated isothermal amplification (RT-LAMP) for the detection of Asian lineage ZIKV in field-caught mosquitoes. Acta Trop 2022; 236:106691. [PMID: 36103950 DOI: 10.1016/j.actatropica.2022.106691] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 09/09/2022] [Accepted: 09/10/2022] [Indexed: 11/01/2022]
Abstract
The Zika virus (ZIKV) infection is an emerging and re-emerging arbovirus infection that is transmitted to humans through the bite of infected mosquitoes. Early detection of ZIKV in mosquitoes is one of the prerequisite approaches for tracking the spread of the virus. Therefore, this study aims to develop and validate a visual reverse transcription-loop-mediated isothermal amplification (RT-LAMP) method called ZIKV-RT-LAMP, for detecting ZIKV in field collected mosquito samples from Thailand. A single-tube ZIKV-RT-LAMP assay was developed to detect Asian lineage ZIKV RNA. The detection limit and cross-reactivity of ZIKV were investigated. The hemi-nested RT-PCR (hn-RT-PCR) and the colorimetric LAMP kit (cLAMP kit) were performed as reference assays. The detection limit of the ZIKV-RT-LAMP assay was 10-6 ffu/ml or pfu/ml, making it highly specific and 100 times more sensitive than the hn-RT-PCR and cLAMP kits. The ZIKV-RT-LAMP assay detected the Asian lineage of ZIKV RNA without cross-reactivity with other arthropod-borne viruses. The sensitivity and specificity of the ZIKV-RT-LAMP assay were 92.31% and 100%, respectively. The ZIKV-RT-LAMP is a simple, rapid, and inexpensive method for detecting ZIKV in field-caught mosquitos. In the future, extensive surveys of field-caught mosquito populations should be conducted. Early detection of ZIKV in field-caught mosquitoes provides for prompt and effective implementation of mosquito control strategies in endemic areas.
Collapse
Affiliation(s)
- Padet Siriyasatien
- Center of Excellence in Vector Biology and Vector Borne Diseases, Department of Parasitology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand; Department of Parasitology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
| | - Supaporn Wacharapluesadee
- Thai Red Cross Emerging Infectious Diseases Clinical Centre, King Chulalongkorn Memorial Hospital, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
| | - Kanyarat Kraivichian
- Department of Parasitology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
| | - Charuai Suwanbamrung
- School of Public Health, Walailak University, Nakhon Si Thammarat, Thailand; Excellent Center for Dengue and Community Public Health (EC for DACH), Walailak University, Nakhon Si Thammarat 80160, Thailand
| | - Nataya Sutthanont
- Department of Medical Entomology, Faculty of Tropical Medicine, Mahidol University Bangkok 10400, Thailand
| | - Ana Cantos-Barreda
- Department of Biochemistry and Molecular Biology-A, Faculty of Veterinary Medicine, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, Espinardo, Murcia 30100, Spain
| | - Atchara Phumee
- Excellent Center for Dengue and Community Public Health (EC for DACH), Walailak University, Nakhon Si Thammarat 80160, Thailand; Department of Medical Technology, School of Allied Health Sciences, Walailak University, Nakhon Si Thammarat 80160, Thailand.
| |
Collapse
|
9
|
Huang Z, Li J, Zhong H, Tian B. Nucleic acid amplification strategies for volume-amplified magnetic nanoparticle detection assay. Front Bioeng Biotechnol 2022; 10:939807. [PMID: 36032733 PMCID: PMC9399362 DOI: 10.3389/fbioe.2022.939807] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 07/11/2022] [Indexed: 12/26/2022] Open
Abstract
Magnetic nanoparticles (MNPs) can be quantified based on their magnetic relaxation properties by volumetric magnetic biosensing strategies, for example, alternating current susceptometry. Volume-amplified magnetic nanoparticle detection assays (VAMNDAs) employ analyte-initiated nucleic acid amplification (NAA) reactions to increase the hydrodynamic size of MNP labels for magnetic sensing, achieving attomolar to picomolar detection limits. VAMNDAs offer rapid and user-friendly analysis of nucleic acid targets but present inherence defects determined by the chosen amplification reactions and sensing principles. In this mini-review, we summarize more than 30 VAMNDA publications and classify their detection models for NAA-induced MNP size increases, highlighting the performances of different linear, cascade, and exponential NAA strategies. For some NAA strategies that have not yet been reported in VAMNDA, we predicted their performances based on the reaction kinetics and feasible detection models. Finally, challenges and perspectives are given, which may hopefully inspire and guide future VAMNDA studies.
Collapse
|
10
|
Ahuja S, Kumar MS, Nandeshwar R, Kondabagil K, Tallur S. Longer amplicons provide better sensitivity for electrochemical sensing of viral nucleic acid in water samples using PCB electrodes. Sci Rep 2022; 12:8814. [PMID: 35614180 PMCID: PMC9130999 DOI: 10.1038/s41598-022-12818-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Accepted: 05/04/2022] [Indexed: 12/13/2022] Open
Abstract
The importance of monitoring environmental samples has gained a lot of prominence since the onset of COVID-19 pandemic, and several surveillance efforts are underway using gold standard, albeit expensive qPCR-based techniques. Electrochemical DNA biosensors could offer a potential cost-effective solution suitable for monitoring of environmental water samples in lower middle income countries. In this work, we demonstrate electrochemical detection of amplicons as long as [Formula: see text] obtained from Phi6 bacteriophage (a popular surrogate for SARS-CoV-2) isolated from spiked lake water samples, using ENIG finish PCB electrodes with no surface modification. The electrochemical sensor response is thoroughly characterised for two DNA fragments of different lengths ([Formula: see text] and [Formula: see text]), and the impact of salt in PCR master mix on methylene blue (MB)-DNA interactions is studied. Our findings establish that length of the DNA fragment significantly determines electrochemical sensitivity, and the ability to detect long amplicons without gel purification of PCR products demonstrated in this work bodes well for realisation of fully-automated solutions for in situ measurement of viral load in water samples.
Collapse
Affiliation(s)
- Shruti Ahuja
- Centre for Research in Nanotechnology and Science (CRNTS), IIT Bombay, Mumbai, 400076, India
| | - M Santhosh Kumar
- Department of Biosciences and Bioengineering (BSBE), IIT Bombay, Mumbai, 400076, India
| | - Ruchira Nandeshwar
- Department of Electrical Engineering (EE), IIT Bombay, Mumbai, 400076, India
| | - Kiran Kondabagil
- Department of Biosciences and Bioengineering (BSBE), IIT Bombay, Mumbai, 400076, India.
| | - Siddharth Tallur
- Department of Electrical Engineering (EE), IIT Bombay, Mumbai, 400076, India.
| |
Collapse
|
11
|
De Falco M, De Felice M, Rota F, Zappi D, Antonacci A, Scognamiglio V. Next-generation diagnostics: augmented sensitivity in amplification-powered biosensing. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
12
|
Usha SP, Manoharan H, Deshmukh R, Álvarez-Diduk R, Calucho E, Sai VVR, Merkoçi A. Attomolar analyte sensing techniques (AttoSens): a review on a decade of progress on chemical and biosensing nanoplatforms. Chem Soc Rev 2021; 50:13012-13089. [PMID: 34673860 DOI: 10.1039/d1cs00137j] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Detecting the ultra-low abundance of analytes in real-life samples, such as biological fluids, water, soil, and food, requires the design and development of high-performance biosensing modalities. The breakthrough efforts from the scientific community have led to the realization of sensing technologies that measure the analyte's ultra-trace level, with relevant sensitivity, selectivity, response time, and sampling efficiency, referred to as Attomolar Analyte Sensing Techniques (AttoSens) in this review. In an AttoSens platform, 1 aM detection corresponds to the quantification of 60 target analyte molecules in 100 μL of sample volume. Herein, we review the approaches listed for various sensor probe design, and their sensing strategies that paved the way for the detection of attomolar (aM: 10-18 M) concentration of analytes. A summary of the technological advances made by the diverse AttoSens trends from the past decade is presented.
Collapse
Affiliation(s)
- Sruthi Prasood Usha
- Biomedical Engineering, Department of Applied Mechanics, Indian Institute of Technology Madras (IITM), India.
| | - Hariharan Manoharan
- Biomedical Engineering, Department of Applied Mechanics, Indian Institute of Technology Madras (IITM), India.
| | - Rehan Deshmukh
- Biomedical Engineering, Department of Applied Mechanics, Indian Institute of Technology Madras (IITM), India.
| | - Ruslan Álvarez-Diduk
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), Campus UAB, Barcelona, Spain.
| | - Enric Calucho
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), Campus UAB, Barcelona, Spain.
| | - V V R Sai
- Biomedical Engineering, Department of Applied Mechanics, Indian Institute of Technology Madras (IITM), India.
| | - Arben Merkoçi
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), Campus UAB, Barcelona, Spain. .,ICREA, Institució Catalana de Recercai Estudis Avançats, Barcelona, Spain
| |
Collapse
|
13
|
Kim E, Lim EK, Park G, Park C, Lim JW, Lee H, Na W, Yeom M, Kim J, Song D, Haam S. Advanced Nanomaterials for Preparedness Against (Re-)Emerging Viral Diseases. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2005927. [PMID: 33586180 DOI: 10.1002/adma.202005927] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 10/08/2020] [Indexed: 05/24/2023]
Abstract
While the coronavirus disease (COVID-19) accounts for the current global pandemic, the emergence of other unknown pathogens, named "Disease X," remains a serious concern in the future. Emerging or re-emerging pathogens continue to pose significant challenges to global public health. In response, the scientific community has been urged to create advanced platform technologies to meet the ever-increasing needs presented by these devastating diseases with pandemic potential. This review aims to bring new insights to allow for the application of advanced nanomaterials in future diagnostics, vaccines, and antiviral therapies, thereby addressing the challenges associated with the current preparedness strategies in clinical settings against viruses. The application of nanomaterials has advanced medicine and provided cutting-edge solutions for unmet needs. Herein, an overview of the currently available nanotechnologies is presented, highlighting the significant features that enable them to control infectious diseases, and identifying the challenges that remain to be addressed for the commercial production of nano-based products is presented. Finally, to conclude, the development of a nanomaterial-based system using a "One Health" approach is suggested. This strategy would require a transdisciplinary collaboration and communication between all stakeholders throughout the entire process spanning across research and development, as well as the preclinical, clinical, and manufacturing phases.
Collapse
Affiliation(s)
- Eunjung Kim
- Department of Bioengineering and Nano-Bioengineering, Incheon National University, Incheon, 22012, Republic of Korea
- Division of Bioengineering, Incheon National University, Incheon, 22012, Republic of Korea
| | - Eun-Kyung Lim
- BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon, 34141, Republic of Korea
- Department of Nanobiotechnology, KRIBB School of Biotechnology, UST, Daejeon, 34113, Republic of Korea
| | - Geunseon Park
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul, 03722, Republic of Korea
| | - Chaewon Park
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul, 03722, Republic of Korea
| | - Jong-Woo Lim
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul, 03722, Republic of Korea
| | - Hyo Lee
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul, 03722, Republic of Korea
| | - Woonsung Na
- College of Veterinary Medicine, Chonnam National University, Gwangju, 61186, Republic of Korea
| | - Minjoo Yeom
- College of Pharmacy, Korea University, Sejong-ro, Sejong, 30019, Republic of Korea
| | - Jinyoung Kim
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul, 03722, Republic of Korea
| | - Daesub Song
- College of Pharmacy, Korea University, Sejong-ro, Sejong, 30019, Republic of Korea
| | - Seungjoo Haam
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul, 03722, Republic of Korea
| |
Collapse
|
14
|
Taguchi array optimization of the reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for sensitive and rapid detection of dengue virus serotype 2. Biotechnol Lett 2021; 43:2149-2160. [PMID: 34533679 DOI: 10.1007/s10529-021-03175-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Accepted: 08/26/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES Serotype 2 of dengue virus (DENV-2) is the most prevalent cause of dengue fevers. In this study, the C-prM gene was used for specific detection of DENV-2 by RT-LAMP assay. The RT-LAMP assay was optimized using the Taguchi design of experiments. RESULTS The efficiency of the assay in such optimal conditions resulted in 100% sensitivity, 100% specificity, and 100% overall accuracy for detection of 4 copies/μL of the genome of DENV-2. In addition, the detection of 2 copies/μL of the genome of DENV-2 was feasible, although the sensitivity was 50%. Considering the importance of the specific detection of the dengue virus serotypes, the cost-effective RT-LAMP approach can be used for rapid, specific, and sensitive detection of DENV-2. CONCLUSION RT-LAMP, as a cost-effective method, was optimized using Taguchi array approach for specific and rapid detection of DENV-2. Such methods can facilitate the diagnosis procedure in remote regions.
Collapse
|
15
|
Soroka M, Wasowicz B, Rymaszewska A. Loop-Mediated Isothermal Amplification (LAMP): The Better Sibling of PCR? Cells 2021; 10:1931. [PMID: 34440699 PMCID: PMC8393631 DOI: 10.3390/cells10081931] [Citation(s) in RCA: 127] [Impact Index Per Article: 42.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 07/26/2021] [Accepted: 07/27/2021] [Indexed: 12/11/2022] Open
Abstract
In 1998, when the PCR technique was already popular, a Japanese company called Eiken Chemical Co., Ltd. designed a method known as the loop-mediated isothermal amplification of DNA (LAMP). The method can produce up to 109 copies of the amplified DNA within less than an hour. It is also highly specific due to the use of two to three pairs of primers (internal, external, and loop), which recognise up to eight specific locations on the DNA or RNA targets. Furthermore, the Bst DNA polymerase most used in LAMP shows a high strand displacement activity, which eliminates the DNA denaturation stage. One of the most significant advantages of LAMP is that it can be conducted at a stable temperature, for instance, in a dry block heater or an incubator. The products of LAMP can be detected much faster than in standard techniques, sometimes only requiring analysis with the naked eye. The following overview highlights the usefulness of LAMP and its effectiveness in various fields; it also considers the superiority of LAMP over PCR and presents RT-LAMP as a rapid diagnostic tool for SARS-CoV-2.
Collapse
Affiliation(s)
| | - Barbara Wasowicz
- Department of Genetics and Genomics, Institute of Biology, University of Szczecin, 3c Felczaka St., 71-412 Szczecin, Poland; (M.S.); (A.R.)
| | | |
Collapse
|
16
|
Mori A, Pomari E, Deiana M, Perandin F, Caldrer S, Formenti F, Mistretta M, Orza P, Ragusa A, Piubelli C. Molecular techniques for the genomic viral RNA detection of West Nile, Dengue, Zika and Chikungunya arboviruses: a narrative review. Expert Rev Mol Diagn 2021; 21:591-612. [PMID: 33910444 DOI: 10.1080/14737159.2021.1924059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Introduction: Molecular technology has played an important role in arboviruses diagnostics. PCR-based methods stand out in terms of sensitivity, specificity, cost, robustness, and accessibility, and especially the isothermal amplification (IA) method is ideal for field-adaptable diagnostics in resource-limited settings (RLS).Areas covered: In this review, we provide an overview of the various molecular methods for West Nile, Zika, Dengue and Chikungunya. We summarize literature works reporting the assessment and use of in house and commercial assays. We describe limitations and challenges in the usage of methods and opportunities for novel approaches such as NNext-GenerationSequencing (NGS).Expert opinion: The rapidity and accuracy of differential diagnosis is essential for a successful clinical management, particularly in co-circulation area of arboviruses. Several commercial diagnostic molecular assays are available, but many are not affordable by RLS and not usable as Point-of-care/Point-of-need (POC/PON) such as RReal-TimeRT-PCR, Array-based methods and NGS. In contrast, the IA-based system fits better for POC/PON but it is still not ideal for the multiplexing detection system. Improvement in the characterization and validation of current molecular assays is needed to optimize their translation to the point of care.
Collapse
Affiliation(s)
- Antonio Mori
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy.,Department of Diagnostics and Public Health, University of Verona, Verona, Italy
| | - Elena Pomari
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy
| | - Michela Deiana
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy
| | - Francesca Perandin
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy
| | - Sara Caldrer
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy
| | - Fabio Formenti
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy
| | - Manuela Mistretta
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy
| | - Pierantonio Orza
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy
| | - Andrea Ragusa
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy
| | - Chiara Piubelli
- Department of Infectious-Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Italy
| |
Collapse
|
17
|
The mechanism and improvements to the isothermal amplification of nucleic acids, at a glance. Anal Biochem 2021; 631:114260. [PMID: 34023274 DOI: 10.1016/j.ab.2021.114260] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 05/15/2021] [Accepted: 05/18/2021] [Indexed: 01/08/2023]
Abstract
A comparative review of the most common isothermal methods is provided. In the last two decades, the challenge of using isothermal amplification systems as an alternate to the most extensive and long-standing nucleic acids-amplifying method-the polymerase chain reaction-has arisen. The main advantage of isothermal amplification is no requirement for expensive laboratory equipment for thermal cycling. Considerable efforts have been made to improve the current techniques of nucleic acid amplification and the development of new approaches based on the main drawbacks of each method. The most important and challenging goal was to achieve a low-cost, straightforward system that is rapid, specific, accurate, and sensitive.
Collapse
|
18
|
Banik S, Melanthota SK, Arbaaz, Vaz JM, Kadambalithaya VM, Hussain I, Dutta S, Mazumder N. Recent trends in smartphone-based detection for biomedical applications: a review. Anal Bioanal Chem 2021; 413:2389-2406. [PMID: 33586007 PMCID: PMC7882471 DOI: 10.1007/s00216-021-03184-z] [Citation(s) in RCA: 65] [Impact Index Per Article: 21.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 12/14/2020] [Accepted: 01/18/2021] [Indexed: 11/06/2022]
Abstract
Smartphone-based imaging devices (SIDs) have shown to be versatile and have a wide range of biomedical applications. With the increasing demand for high-quality medical services, technological interventions such as portable devices that can be used in remote and resource-less conditions and have an impact on quantity and quality of care. Additionally, smartphone-based devices have shown their application in the field of teleimaging, food technology, education, etc. Depending on the application and imaging capability required, the optical arrangement of the SID varies which enables them to be used in multiple setups like bright-field, fluorescence, dark-field, and multiple arrays with certain changes in their optics and illumination. This comprehensive review discusses the numerous applications and development of SIDs towards histopathological examination, detection of bacteria and viruses, food technology, and routine diagnosis. Smartphone-based devices are complemented with deep learning methods to further increase the efficiency of the devices. Graphical Abstract.
Collapse
Affiliation(s)
- Soumyabrata Banik
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Sindhoora Kaniyala Melanthota
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Arbaaz
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Joel Markus Vaz
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Vishak Madhwaraj Kadambalithaya
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Iftak Hussain
- Center for Healthcare Entrepreneurship, Indian Institute of Technology, Hyderabad, Telangana, 502285, India
| | - Sibasish Dutta
- Department of Physics, Pandit Deendayal Upadhyaya Adarsha Mahavidyalaya (PDUAM), Eraligool, Karimganj, Assam, 788723, India
| | - Nirmal Mazumder
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
| |
Collapse
|
19
|
Duarte JL, Filippo LDD, Araujo VHS, Oliveira AEMDFM, de Araújo JTC, Silva FBDR, Pinto MC, Chorilli M. Nanotechnology as a tool for detection and treatment of arbovirus infections. Acta Trop 2021; 216:105848. [PMID: 33524384 DOI: 10.1016/j.actatropica.2021.105848] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 01/21/2021] [Accepted: 01/23/2021] [Indexed: 12/19/2022]
Abstract
Arboviruses are medically important viruses that cause high rates of infection all over the world. In addition, the severity of the symptoms and the inadequate diagnostic methods represent a challenge far beyond eradicating the vector. The lack of specific treatments for arbovirus infections reflects the imminent need for new research for safe and efficient medicines to treat these infections. Nanotechnology is an innovative approach currently used as a platform for developing new treatments, thus improving the biopharmaceutical properties of drugs. It can also be applied to the development of diagnostic devices, improving their detection capacity. The purpose of this paper is to review recent research on the use of nanotechnology for developing new treatments and detection devices for arbovirus infections. Interestingly, it was found that only a few studies report on the use of nanotechnology to treat arbovirus infections and that most of these reports focus on the fabrication of diagnostic tools. Also, some papers report on the use of nanotechnology for the development of vaccines, which in association with mosquito eradication programs could effectively reduce the high rates of infections by these viruses.
Collapse
Affiliation(s)
- Jonatas Lobato Duarte
- São Paulo State University - UNESP, School of Pharmaceutical Sciences, Rodovia Araraquara Jaú, Km 01 - s/n - Campos Ville - Araraquara/SP -, 14800-903, Brazil
| | - Leonardo Delello Di Filippo
- São Paulo State University - UNESP, School of Pharmaceutical Sciences, Rodovia Araraquara Jaú, Km 01 - s/n - Campos Ville - Araraquara/SP -, 14800-903, Brazil
| | - Victor Hugo Sousa Araujo
- São Paulo State University - UNESP, School of Pharmaceutical Sciences, Rodovia Araraquara Jaú, Km 01 - s/n - Campos Ville - Araraquara/SP -, 14800-903, Brazil
| | - Anna Eliza Maciel de Faria Mota Oliveira
- Federal University of Amapá - UNIFAP, Department of Health and biological sciences, Rodovia Juscelino Kubitschek, Km 02, Jardim Marco Zero, Macapá-AP, 68903-361, Brazil
| | - Jennifer Thayanne Cavalcante de Araújo
- São Paulo State University - UNESP, School of Pharmaceutical Sciences, Rodovia Araraquara Jaú, Km 01 - s/n - Campos Ville - Araraquara/SP -, 14800-903, Brazil
| | - Flávia Benini da Rocha Silva
- São Paulo State University - UNESP, School of Pharmaceutical Sciences, Rodovia Araraquara Jaú, Km 01 - s/n - Campos Ville - Araraquara/SP -, 14800-903, Brazil
| | - Mara Cristina Pinto
- São Paulo State University - UNESP, School of Pharmaceutical Sciences, Rodovia Araraquara Jaú, Km 01 - s/n - Campos Ville - Araraquara/SP -, 14800-903, Brazil
| | - Marlus Chorilli
- São Paulo State University - UNESP, School of Pharmaceutical Sciences, Rodovia Araraquara Jaú, Km 01 - s/n - Campos Ville - Araraquara/SP -, 14800-903, Brazil.
| |
Collapse
|
20
|
Zhong J, Rösch EL, Viereck T, Schilling M, Ludwig F. Toward Rapid and Sensitive Detection of SARS-CoV-2 with Functionalized Magnetic Nanoparticles. ACS Sens 2021; 6:976-984. [PMID: 33496572 PMCID: PMC7860137 DOI: 10.1021/acssensors.0c02160] [Citation(s) in RCA: 50] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 01/18/2021] [Indexed: 12/17/2022]
Abstract
The outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) threatens global medical systems and economies and rules our daily living life. Controlling the outbreak of SARS-CoV-2 has become one of the most important and urgent strategies throughout the whole world. As of October 2020, there have not yet been any medicines or therapies to be effective against SARS-CoV-2. Thus, rapid and sensitive diagnostics is the most important measures to control the outbreak of SARS-CoV-2. Homogeneous biosensing based on magnetic nanoparticles (MNPs) is one of the most promising approaches for rapid and highly sensitive detection of biomolecules. This paper proposes an approach for rapid and sensitive detection of SARS-CoV-2 with functionalized MNPs via the measurement of their magnetic response in an ac magnetic field. For proof of concept, mimic SARS-CoV-2 consisting of spike proteins and polystyrene beads are used for experiments. Experimental results demonstrate that the proposed approach allows the rapid detection of mimic SARS-CoV-2 with a limit of detection of 0.084 nM (5.9 fmole). The proposed approach has great potential for designing a low-cost and point-of-care device for rapid and sensitive diagnostics of SARS-CoV-2.
Collapse
Affiliation(s)
- Jing Zhong
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| | - Enja Laureen Rösch
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| | - Thilo Viereck
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| | - Meinhard Schilling
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| | - Frank Ludwig
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| |
Collapse
|
21
|
An innovative and user-friendly smartphone-assisted molecular diagnostic approach for rapid detection of canine vector-borne diseases. Parasitol Res 2021; 120:1799-1809. [PMID: 33649963 PMCID: PMC7920752 DOI: 10.1007/s00436-021-07077-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 02/01/2021] [Indexed: 11/17/2022]
Abstract
Present-day diagnostic tools and technologies for canine diseases and other vector-borne parasitic diseases hardly meet the requirements of an efficient and rapid diagnostic tool, which can be suitable for use at the point-of-care in resource-limited settings. Loop-mediated isothermal amplification (LAMP) technique has been always a method of choice in the development and validation of quick, precise, and sensitive diagnostic assays for pathogen detection and to reorganize point-of-care (POC) molecular diagnostics. In this study, we have demonstrated an efficient detection system for parasitic vector-borne pathogens like Ehrlichia canis and Hepatozoon canis by linking the LAMP assay to a smartphone via a simple, inexpensive, and a portable “LAMP box,” All the components of the LAMP box were connected to each other wirelessly. This LAMP box was made up of an isothermal heating pad mounted below an aluminum base which served as a platform for the reaction tubes and LAMP assay. The entire setup could be connected to a smartphone via an inbuilt Wi-Fi that allowed the user to establish the connection to control the LAMP box. A 5 V USB power source was used as a power supply. The sensitivity of the LAMP assay was estimated to be up to 10−6 dilution limit using the amplified, purified, and quantified specific DNA templates. It can also serve as an efficient diagnostic platform for many other veterinary infectious or parasitic diseases of zoonotic origin majorly towards field-based diagnostics.
Collapse
|
22
|
da Silva SJR, Pardee K, Balasuriya UBR, Pena L. Development and validation of a one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of ZIKV in patient samples from Brazil. Sci Rep 2021; 11:4111. [PMID: 33602985 PMCID: PMC7893177 DOI: 10.1038/s41598-021-83371-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Accepted: 01/18/2021] [Indexed: 01/03/2023] Open
Abstract
We have previously developed and validated a one-step assay based on reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of the Zika virus (ZIKV) from mosquito samples. Patient diagnosis of ZIKV is currently carried out in centralized laboratories using the reverse transcription-quantitative polymerase chain reaction (RT-qPCR), which, while the gold standard molecular method, has several drawbacks for use in remote and low-resource settings, such as high cost and the need of specialized equipment. Point-of-care (POC) diagnostic platforms have the potential to overcome these limitations, especially in low-resource countries where ZIKV is endemic. With this in mind, here we optimized and validated our RT-LAMP assay for rapid detection of ZIKV from patient samples. We found that the assay detected ZIKV from diverse sample types (serum, urine, saliva, and semen) in as little as 20 min, without RNA extraction. The RT-LAMP assay was highly specific and up to 100 times more sensitive than RT-qPCR. We then validated the assay using 100 patient serum samples collected from suspected cases of arbovirus infection in the state of Pernambuco, which was at the epicenter of the last Zika epidemic. Analysis of the results, in comparison to RT-qPCR, found that the ZIKV RT-LAMP assay provided sensitivity of 100%, specificity of 93.75%, and an overall accuracy of 95.00%. Taken together, the RT-LAMP assay provides a straightforward and inexpensive alternative for the diagnosis of ZIKV from patients and has the potential to increase diagnostic capacity in ZIKV-affected areas, particularly in low and middle-income countries.
Collapse
Affiliation(s)
- Severino Jefferson Ribeiro da Silva
- Department of Virology, Aggeu Magalhães Institute (IAM), Oswaldo Cruz Foundation (Fiocruz), Avenida Professor Moraes Rego, Recife, Pernambuco, 50670-420, Brazil
| | - Keith Pardee
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON, M5S 3M2, Canada
| | - Udeni B R Balasuriya
- Louisiana Animal Disease Diagnostic Laboratory and Department of Pathobiological Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA, USA
| | - Lindomar Pena
- Department of Virology, Aggeu Magalhães Institute (IAM), Oswaldo Cruz Foundation (Fiocruz), Avenida Professor Moraes Rego, Recife, Pernambuco, 50670-420, Brazil.
| |
Collapse
|
23
|
Zhang X, Li G, Chen G, Zhu N, Wu D, Wu Y, James TD. Recent progresses and remaining challenges for the detection of Zika virus. Med Res Rev 2021; 41:2039-2108. [PMID: 33559917 DOI: 10.1002/med.21786] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 12/23/2020] [Accepted: 01/05/2021] [Indexed: 12/26/2022]
Abstract
Zika virus (ZIKV) has emerged as a particularly notorious mosquito-borne flavivirus, which can lead to a devastating congenital syndrome in the fetuses of pregnant mothers (e.g., microcephaly, spasticity, craniofacial disproportion, miscarriage, and ocular abnormalities) and cause the autoimmune disorder Guillain-Barre' syndrome of adults. Due to its severity and rapid dispersal over several continents, ZIKV has been acknowledged to be a global health concern by the World Health Organization. Unfortunately, the ZIKV has recently resurged in India with the potential for devastating effects. Researchers from all around the world have worked tirelessly to develop effective detection strategies and vaccines for the prevention and control of ZIKV infection. In this review, we comprehensively summarize the most recent research into ZIKV, including the structural biology and evolution, historical overview, pathogenesis, symptoms, and transmission. We then focus on the detection strategies for ZIKV, including viral isolation, serological assays, molecular assays, sensing methods, reverse transcription loop mediated isothermal amplification, transcription-mediated amplification technology, reverse transcription strand invasion based amplification, bioplasmonic paper-based device, and reverse transcription isothermal recombinase polymerase amplification. To conclude, we examine the limitations of currently available strategies for the detection of ZIKV, and outline future opportunities and research challenges.
Collapse
Affiliation(s)
- Xianlong Zhang
- School of Food and Biological Engineering, Shaanxi University of Science and Technology, Xi'an, China
| | - Guoliang Li
- School of Food and Biological Engineering, Shaanxi University of Science and Technology, Xi'an, China
| | - Guang Chen
- School of Food and Biological Engineering, Shaanxi University of Science and Technology, Xi'an, China
| | - Niu Zhu
- Department of Public Health, Xi'an Medical University, Xi'an, China
| | - Di Wu
- Institute for Global Food Security, Queen's University Belfast, Belfast, UK
| | - Yongning Wu
- NHC Key Laboratory of Food Safety Risk Assessment, Food Safety Research Unit (2019RU014) of Chinese Academy of Medical Science, China National Center for Food Safety Risk Assessment, Beijing, China
| | - Tony D James
- Department of Chemistry, University of Bath, Bath, UK.,School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, China
| |
Collapse
|
24
|
Song J, Kim HY, Kim S, Jung Y, Park HG. Self-priming phosphorothioated hairpin-mediated isothermal amplification. Biosens Bioelectron 2021; 178:113051. [PMID: 33548651 DOI: 10.1016/j.bios.2021.113051] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 01/21/2021] [Accepted: 01/27/2021] [Indexed: 01/06/2023]
Abstract
We herein describe a novel technology, termed self-priming phosphorothioated hairpin-mediated isothermal amplification (SP-HAMP), enabling target nucleic acid detection. Isothermal amplification strategies are a simple process that efficiently raises the amount of nucleic acid at a constant temperature, but still has lots of problems such as the requirement of multiple exogenous primers and enzymes, which trigger non-specific background signal and increase the complexity of procedures. The key component for overcoming the above-mentioned limitations is the designed hairpin probe (HP) consisting of self-priming region along the 3' stem and the 3' overhang and phosphorothioate modifications at the 5' overhang and the specific loop part. The HP was designed to open through binding to target nucleic acid. Upon opening of HP, its self-priming (SP) region is rearranged to form a smaller hairpin whose 3' end could serve as a primer. The following extension produces the extended HP and displaces the bound target nucleic acid, which is then recycled to open another HP. Due to the reduced stability caused by the specific two phosphorothioate (PS) modifications, the 3' end of EP1 is readily rearranged to form the foldback hairpin structure, which would promote the foldback extension to produce once more extended HP. Since the two PS modifications are always located at the same positions along the 5' stem within the further extended HPs, the foldback reaction followed by the extension would be continuously repeated, consequently producing a large number of the long hairpin concatamers. Based on this unique design principle, we successfully detected even a single copy of target DNA with outstanding discrimination capability under an isothermal condition by employing only a single HP without the requirement for the complicated multiple primers. In conclusion, the sophisticated design principle employed in this work would provide great insight for the development of self-operative isothermal amplifying system enabling short target nucleic acid detection such as microRNAs or any target which is less than 200 mer.
Collapse
Affiliation(s)
- Jayeon Song
- Department of Chemical and Biomolecular Engineering (BK 21+ Program), KAIST, Daehak-ro 291, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Hyo Yong Kim
- Department of Chemical and Biomolecular Engineering (BK 21+ Program), KAIST, Daehak-ro 291, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Soohyun Kim
- Department of Chemical and Biomolecular Engineering (BK 21+ Program), KAIST, Daehak-ro 291, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Yujin Jung
- Department of Chemical and Biomolecular Engineering (BK 21+ Program), KAIST, Daehak-ro 291, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Hyun Gyu Park
- Department of Chemical and Biomolecular Engineering (BK 21+ Program), KAIST, Daehak-ro 291, Yuseong-gu, Daejeon, 34141, Republic of Korea.
| |
Collapse
|
25
|
Xu LD, Du FL, Zhu J, Ding SN. Luminous silica colloids with carbon dot incorporation for sensitive immunochromatographic assay of Zika virus. Analyst 2021; 146:706-713. [DOI: 10.1039/d0an02017f] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Fluorescent SiO2 colloids prepared from silanized CDs embedded in silica spheres were integrated with an immunochromatographic platform for Zika virus detection.
Collapse
Affiliation(s)
- Lai-Di Xu
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research
- School of Chemistry and Chemical Engineering
- Southeast University
- Nanjing 211189
- China
| | - Feng-Luan Du
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research
- School of Chemistry and Chemical Engineering
- Southeast University
- Nanjing 211189
- China
| | - Jin Zhu
- Huadong Medical Institute of Biotechniques
- Nanjing 210002
- China
| | - Shou-Nian Ding
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research
- School of Chemistry and Chemical Engineering
- Southeast University
- Nanjing 211189
- China
| |
Collapse
|
26
|
Teoh BT, Chin KL, Samsudin NI, Loong SK, Sam SS, Tan KK, Khor CS, Abd-Jamil J, Zainal N, Wilder-Smith A, Zandi K, AbuBakar S. A reverse transcription loop-mediated isothermal amplification for broad coverage detection of Asian and African Zika virus lineages. BMC Infect Dis 2020; 20:947. [PMID: 33308203 PMCID: PMC7731766 DOI: 10.1186/s12879-020-05585-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 11/04/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Early detection of Zika virus (ZIKV) infection during the viremia and viruria facilitates proper patient management and mosquito control measurement to prevent disease spread. Therefore, a cost-effective nucleic acid detection method for the diagnosis of ZIKV infection, especially in resource-deficient settings, is highly required. METHODS In the present study, a single-tube reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of both the Asian and African-lineage ZIKV. The detection limit, strain coverage and cross-reactivity of the ZIKV RT-LAMP assay was evaluated. The sensitivity and specificity of the RT-LAMP were also evaluated using a total of 24 simulated clinical samples. The ZIKV quantitative reverse transcription-polymerase chain reaction (qRT-PCR) assay was used as the reference assay. RESULTS The detection limit of the RT-LAMP assay was 3.73 ZIKV RNA copies (probit analysis, P ≤ 0.05). The RT-LAMP assay detected the ZIKV genomes of both the Asian and African lineages without cross-reacting with other arthropod-borne viruses. The sensitivity and specificity of the RT-LAMP assay were 90% (95% CI = 59.6-98.2) and 100% (95% CI = 78.5-100.0), respectively. The RT-LAMP assay detected ZIKV genome in 9 of 24 (37.5%) of the simulated clinical samples compared to 10 of 24 (41.7%) by qRT-PCR assay with a high level of concordance (κ = 0.913, P < 0.001). CONCLUSION The RT-LAMP assay is applicable for the broad coverage detection of both the Asian and African ZIKV strains in resource-deficient settings.
Collapse
Affiliation(s)
- Boon-Teong Teoh
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia.
| | - Kim-Ling Chin
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia.,Institute for Advanced Studies (IAS), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Nur-Izyan Samsudin
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Shih-Keng Loong
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Sing-Sin Sam
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Kim-Kee Tan
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Chee-Sieng Khor
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Juraina Abd-Jamil
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Nurhafiza Zainal
- Department of Medical Microbiology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Annelies Wilder-Smith
- Department of Public Health and Clinical Medicine, Epidemiology and Global Health, Umeå University, Umeå, Sweden.,Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Republic of Singapore
| | - Keivan Zandi
- Department of Medical Microbiology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.,Center for AIDS Research, Laboratory of Biochemical Pharmacology, Department of Pediatrics, Emory University School of Medicine, Atlanta, GA, USA
| | - Sazaly AbuBakar
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Universiti Malaya, Kuala Lumpur, Malaysia. .,Department of Medical Microbiology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
| |
Collapse
|
27
|
Oropesa-Nuñez R, Zardán Gómez de la Torre T, Stopfel H, Svedlindh P, Strömberg M, Gunnarsson K. Insights into the Formation of DNA-Magnetic Nanoparticle Hybrid Structures: Correlations between Morphological Characterization and Output from Magnetic Biosensor Measurements. ACS Sens 2020; 5:3510-3519. [PMID: 33141554 PMCID: PMC7706118 DOI: 10.1021/acssensors.0c01623] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
![]()
Understanding
the binding mechanism between probe-functionalized
magnetic nanoparticles (MNPs) and DNA targets or amplification products
thereof is essential in the optimization of magnetic biosensors for
the detection of DNA. Herein, the molecular interaction forming hybrid
structures upon hybridization between DNA-functionalized magnetic
nanoparticles, exhibiting Brownian relaxation, and rolling circle
amplification products (DNA-coils) is investigated by the use of atomic
force microscopy in a liquid environment and magnetic biosensors measuring
the frequency-dependent magnetic response and the frequency-dependent
modulation of light transmission. This approach reveals the qualitative
and quantitative correlations between the morphological features of
the hybrid structures with their magnetic response. The suppression
of the high-frequency peak in the magnetic response and the appearance
of a new peak at lower frequencies match the formation of larger sized
assemblies upon increasing the concentration of DNA-coils. Furthermore,
an increase of the DNA-coil concentration induces an increase in the
number of MNPs per hybrid structure. This study provides new insights
into the DNA–MNP binding mechanism, and its versatility is
of considerable importance for the mechanistic characterization of
other DNA-nanoparticle biosensor systems.
Collapse
Affiliation(s)
- Reinier Oropesa-Nuñez
- Department of Materials Science and Engineering, Uppsala University, Ångströmlaboratoriet, Box 35, SE-751 03 Uppsala, Sweden
| | - Teresa Zardán Gómez de la Torre
- Department of Materials Science and Engineering, Uppsala University, Ångströmlaboratoriet, Box 35, SE-751 03 Uppsala, Sweden
| | - Henry Stopfel
- Department of Materials Science and Engineering, Uppsala University, Ångströmlaboratoriet, Box 35, SE-751 03 Uppsala, Sweden
| | - Peter Svedlindh
- Department of Materials Science and Engineering, Uppsala University, Ångströmlaboratoriet, Box 35, SE-751 03 Uppsala, Sweden
| | - Mattias Strömberg
- Department of Materials Science and Engineering, Uppsala University, Ångströmlaboratoriet, Box 35, SE-751 03 Uppsala, Sweden
| | - Klas Gunnarsson
- Department of Materials Science and Engineering, Uppsala University, Ångströmlaboratoriet, Box 35, SE-751 03 Uppsala, Sweden
| |
Collapse
|
28
|
Tian B, Fock J, Minero GAS, Hansen MF. Nicking-assisted on-loop and off-loop enzymatic cascade amplification for optomagnetic detection of a highly conserved dengue virus sequence. Biosens Bioelectron 2020; 160:112219. [PMID: 32339155 DOI: 10.1016/j.bios.2020.112219] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 04/13/2020] [Accepted: 04/15/2020] [Indexed: 12/11/2022]
Abstract
Applications of conventional linear ligation-rolling circle amplification (RCA) are restricted by the sophisticated operation steps and unsatisfactory picomolar-level detection limits. We herein demonstrate an RCA-based cascade amplification reaction that converts a side-reaction to secondary amplification, which improves the detection limit and simplifies the operation compared to linear ligation-RCA assays. The proposed nicking-assisted enzymatic cascade amplification (NECA) comprises an on-loop amplification reaction using circular templates to generate intermediate amplicons, and an off-loop amplification reaction using intermediate amplicons as primers for end amplicons. The whole NECA reaction is homogeneous and isothermal. Amplicons anneal to detection probes that are grafted onto magnetic nanoparticles (MNPs), such that MNP clusters form and can be detected in real-time using optomagnetic measurements. The optomagnetic sensor detects the presence and size increase of MNP clusters by optical transmission measurements in an oscillating magnetic field. A detection limit of 2 fM was achieved with a total assay time of ca. 70 min. By combining optomagnetic readouts of signal phase lag and hydrodynamic size increase of MNPs, NECA-based target quantification provided a wide dynamic detection range of ca. 4.5 orders of magnitude. Moreover, the specificity and the serum detection capability of the proposed method were investigated.
Collapse
Affiliation(s)
- Bo Tian
- Department of Health Technology, Technical University of Denmark, DTU Health Tech, Building 345C, DK-2800, Kongens Lyngby, Denmark.
| | - Jeppe Fock
- Blusense Diagnostics ApS, Fruebjergvej 3, DK-2100, Copenhagen, Denmark
| | - Gabriel Antonio S Minero
- Department of Health Technology, Technical University of Denmark, DTU Health Tech, Building 345C, DK-2800, Kongens Lyngby, Denmark
| | - Mikkel Fougt Hansen
- Department of Health Technology, Technical University of Denmark, DTU Health Tech, Building 345C, DK-2800, Kongens Lyngby, Denmark.
| |
Collapse
|
29
|
Hsu YP, Li NS, Chen YT, Pang HH, Wei KC, Yang HW. A serological point-of-care test for Zika virus detection and infection surveillance using an enzyme-free vial immunosensor with a smartphone. Biosens Bioelectron 2020; 151:111960. [DOI: 10.1016/j.bios.2019.111960] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 11/17/2019] [Accepted: 12/09/2019] [Indexed: 12/17/2022]
|
30
|
Yuan H, Chao Y, Shum HC. Droplet and Microchamber-Based Digital Loop-Mediated Isothermal Amplification (dLAMP). SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1904469. [PMID: 31899592 DOI: 10.1002/smll.201904469] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2019] [Revised: 10/22/2019] [Indexed: 05/15/2023]
Abstract
Digital loop-mediated isothermal amplification (dLAMP) refers to compartmentalizing nucleic acids and LAMP reagents into a large number of individual partitions, such as microchambers and droplets. This compartmentalization enables dLAMP to be an excellent platform to quantify the absolute number of the target nucleic acids. Owing to its low requirement for instrumentation complexity, high specificity, and strong tolerance to inhibitors in the nucleic acid samples, dLAMP has been recognized as a simple and accurate technique to quantify pathogenic nucleic acid. Herein, the general process of dLAMP techniques is summarized, the current dLAMP techniques are categorized, and a comprehensive discussion on different types of dLAMP techniques is presented. Also, the challenges of the current dLAMP are illustrated together with the possible strategies to address these challenges. In the end, the future directions of the dLAMP developments, including multitarget detection, multisample detection, and processing nucleic acid extraction are outlined. With recently significant advances in dLAMP, this technology has the potential to see more widespread use beyond the laboratory in the future.
Collapse
Affiliation(s)
- Hao Yuan
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, Hong Kong
| | - Youchuang Chao
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, Hong Kong
| | - Ho Cheung Shum
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, Hong Kong
| |
Collapse
|
31
|
Campos EVR, de Oliveira JL, Abrantes DC, Rogério CB, Bueno C, Miranda VR, Monteiro RA, Fraceto LF. Recent Developments in Nanotechnology for Detection and Control of Aedes aegypti-Borne Diseases. Front Bioeng Biotechnol 2020; 8:102. [PMID: 32154233 PMCID: PMC7047929 DOI: 10.3389/fbioe.2020.00102] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 02/03/2020] [Indexed: 11/24/2022] Open
Abstract
Arboviruses such as yellow fever, dengue, chikungunya and zika are transmitted mainly by the mosquito vector Aedes aegypti. Especially in the tropics, inefficacy of mosquito control causes arboviruses outbreaks every year, affecting the general population with debilitating effects in infected individuals. Several strategies have been tried to control the proliferation of A. aegypti using physical, biological, and chemical control measures. Other methods are currently under research and development, amongst which the use of nanotechnology has attracted a lot of attention of the researchers in relation to the production of more effective repellents and larvicides with less toxicity, and development of rapid sensors for the detection of virus infections. In this review, the utilization of nano-based formulations on control and diagnosis of mosquito-borne diseases were discussed. We also emphasizes the need for future research for broad commercialization of nano-based formulations in world market aiming a positive impact on public health.
Collapse
Affiliation(s)
| | | | | | | | - Carolina Bueno
- São Paulo State University—UNESP, Institute of Science and Technology, Sorocaba, Brazil
| | | | | | | |
Collapse
|
32
|
Lopez-Jimena B, Bakheit M, Bekaert M, Harold G, Frischmann S, Fall C, Diagne CT, Faye O, Faye O, Sall AA, Weidmann M. Development and Validation of Real-Time RT-LAMP Assays for the Specific Detection of Zika Virus. Methods Mol Biol 2020; 2142:147-164. [PMID: 32367366 DOI: 10.1007/978-1-0716-0581-3_13] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Two one-step real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays for the detection of Zika virus (ZIKV) were developed, based on two different primer design approaches: (1) open source, based on a combination of sequence diversity clustering (phylogeny and principal component analysis) and LAVA algorithm, using 45 whole genome ZIKV sequences retrieved from the National Center for Biotechnology Information (NCBI) database; (2) standard software for LAMP primer design (Primer Explorer V4), using 59 sequences of the ZIKV 3' UTR. The assays were firstly evaluated with External Quality Assessment panels from INSTAND e.V. (Germany) and EVD-LabNet (The Netherlands) including 4 and 12 unknown samples, respectively, and secondly, with 9 human, mosquito, and monkey ZIKV isolates from Africa (Senegal, Ivory Coast, and Uganda) and America (Brazil). The limit of detection as determined by probit analysis was 181 molecules for both RT-LAMP assays, and 100% reproducibility in the assays was obtained for 103 molecules (4/8 repetitions were positive for 102 molecules). Both assays were specific, amplifying only ZIKV RNA and not cross-detecting other arboviruses included in this study.
Collapse
Affiliation(s)
- Benjamin Lopez-Jimena
- Institute of Aquaculture, University of Stirling, Scotland, UK.
- Centre for Diagnostics Development, LifeArc, Scotland, UK.
| | | | - Michaël Bekaert
- Institute of Aquaculture, University of Stirling, Scotland, UK
| | - Graham Harold
- Institute of Aquaculture, University of Stirling, Scotland, UK
| | | | - Cheikh Fall
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | - Cheikh Tidiane Diagne
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | - Oumar Faye
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | - Ousmane Faye
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | - Amadou Alpha Sall
- Arbovirus and Viral Haemorrhagic Fever Unit, Institut Pasteur de Dakar, Dakar, Senegal
| | | |
Collapse
|
33
|
da Silva SJR, Pardee K, Pena L. Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of Zika Virus: A Review. Viruses 2019; 12:v12010019. [PMID: 31877989 PMCID: PMC7019470 DOI: 10.3390/v12010019] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 11/30/2019] [Accepted: 12/04/2019] [Indexed: 12/17/2022] Open
Abstract
The recent outbreak of Zika virus (ZIKV) in the Americas and its devastating developmental and neurological manifestations has prompted the development of field-based diagnostics that are rapid, reliable, handheld, specific, sensitive, and inexpensive. The gold standard molecular method for lab-based diagnosis of ZIKV, from either patient samples or insect vectors, is reverse transcription-quantitative polymerase chain reaction (RT-qPCR). The method, however, is costly and requires lab-based equipment and expertise, which severely limits its use as a point-of-care (POC) tool in resource-poor settings. Moreover, given the lack of antivirals or approved vaccines for ZIKV infection, a POC diagnostic test is urgently needed for the early detection of new outbreaks and to adequately manage patients. Loop-mediated isothermal amplification (LAMP) is a compelling alternative to RT-qPCR for ZIKV and other arboviruses. This low-cost molecular system can be freeze-dried for distribution and exhibits high specificity, sensitivity, and efficiency. A growing body of evidence suggests that LAMP assays can provide greater accessibility to much-needed diagnostics for ZIKV infections, especially in developing countries where the ZIKV is now endemic. This review summarizes the different LAMP methods that have been developed for the virus and summarizes their features, advantages, and limitations.
Collapse
Affiliation(s)
| | - Keith Pardee
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON M5S 3M2, Canada;
| | - Lindomar Pena
- Department of Virology, Aggeu Magalhaes Institute (IAM), Oswaldo Cruz Foundation (Fiocruz), 50670-420 Recife, Brazil;
- Correspondence: ; Tel.: +55-81-2123-7849
| |
Collapse
|
34
|
Ricotta V, Yu Y, Clayton N, Chuang YC, Wang Y, Mueller S, Levon K, Simon M, Rafailovich M. A chip-based potentiometric sensor for a Zika virus diagnostic using 3D surface molecular imprinting. Analyst 2019; 144:4266-4280. [PMID: 31180088 DOI: 10.1039/c9an00580c] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The latest Zika virus (ZIKV) pandemic caused great international concern from explosively proliferating throughout the Americas. Currently, there is no vaccine to prevent Zika virus infection and available tests rely on antibodies or RNA. Unfortunately, antibody-based detection systems can result in false positive results and RNA-based detection systems are costly, time-consuming, and impractical for testing in remote regions. In this study, a potential point-of-care (POC) diagnostic system was developed using a chip-based potentiometric sensor to detect Zika virus using a 3D molecular imprinting technique. This chip-based potentiometric sensor system was able to detect 10-1 PFU mL-1 ZIKV in a buffered solution under 20 minutes without any sample manipulation. This sensor was tested against Dengue virus at clinical viral loads and showed no sign of cross-reactivity. When tested against human saliva samples containing clinical viral loads, this sensor was able to detect 10 PFU mL-1 ZIKV among the pool of bio-macromolecules. The high sensitivity and high selectivity demonstrated here proved that this lab-on-a-chip diagnostic has the potential to become a POC detection system for rapid and accurate screening of flaviviruses.
Collapse
Affiliation(s)
- Vincent Ricotta
- Department of Materials Science and Engineering, SUNY at Stony Brook, Stony Brook, NY 11794, USA.
| | - Yingjie Yu
- Department of Materials Science and Engineering, SUNY at Stony Brook, Stony Brook, NY 11794, USA.
| | - Nicholas Clayton
- Department of Materials Science and Engineering, SUNY at Stony Brook, Stony Brook, NY 11794, USA.
| | - Ya-Chen Chuang
- Department of Materials Science and Engineering, SUNY at Stony Brook, Stony Brook, NY 11794, USA.
| | - Yantian Wang
- Department of Materials Science and Engineering, SUNY at Stony Brook, Stony Brook, NY 11794, USA.
| | | | - Kalle Levon
- Department of Chemical and Biological Sciences, Polytechnic Institute of NYU, Brooklyn, NY 11201, USA
| | - Marcia Simon
- Department of Oral Biology and Pathology, SUNY at Stony Brook, Stony Brook, NY 11794, USA
| | - Miriam Rafailovich
- Department of Materials Science and Engineering, SUNY at Stony Brook, Stony Brook, NY 11794, USA.
| |
Collapse
|
35
|
Estrela PFN, Mendes GDM, de Oliveira KG, Bailão AM, Soares CMDA, Assunção NA, Duarte GRM. Ten-minute direct detection of Zika virus in serum samples by RT-LAMP. J Virol Methods 2019; 271:113675. [PMID: 31170469 DOI: 10.1016/j.jviromet.2019.113675] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 06/01/2019] [Accepted: 06/02/2019] [Indexed: 01/10/2023]
Abstract
Zika virus (ZIKV) is a current threat to global health. In most of cases, ZIKV infection has no symptoms; however in some cases, ZIKV can cause paralysis (Guillain-Barré syndrome), and in pregnant women, it can cause birth defects in infants. Rapid and accurate diagnosis can help improve disease control as well as being vital to prenatal care for women living in endemic areas. Molecular diagnostics based on isothermal amplification techniques are an excellent alternative to conventional methods of DNA amplification, such as PCR. Here, we develop and optimized a rapid and sensitive method for direct detection of ZIKV in Serum samples based on RT-LAMP and visual detection. The reaction was thermally controlled with a thermoblock for 10 min at 72 °C. The results show that the use of the Bst 3.0 enzyme and an adequate optimization can further reduce the time needed for the RT-LAMP reaction to detect ZIKV. Our results demonstrate that it is possible to detect ZIKV through RT-LAMP directly from a Serum sample, without prior RNA extraction. As little as 10-3 copies of RNA in a 10 μL reaction (20 zepto-molar) was detected by RT-LAMP from a panel of 51 Serum samples (16 samples from pregnant women and 35 samples from newborns infected with ZIKV during pregnancy). The RT-LAMP has proven to be a valuable tool for molecular diagnosis of Zika, presenting a great potential for point-of-care applications, especially in developing countries.
Collapse
Affiliation(s)
| | | | | | - Alexandre Melo Bailão
- Instituto de Ciências Biológicas, Universidade Federal de Goiás, Goiânia, GO, 74690-900, Brazil
| | | | - Nilson Antônio Assunção
- Instituto de Ciências Ambientais, Químicas e Farmacêuticas, Universidade Federal de São Paulo, São Paulo, SP, 04021-001, Brazil
| | | |
Collapse
|
36
|
Pawley D, Ricciardi MJ, Dikici E, Deo SK, Daunert S. Highly Sensitive and Selective Direct Detection of Zika Virus Particles in Human Bodily Fluids for Accurate Early Diagnosis of Infection. ACS OMEGA 2019; 4:6808-6818. [PMID: 31058250 PMCID: PMC6492231 DOI: 10.1021/acsomega.9b00374] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Accepted: 04/01/2019] [Indexed: 05/31/2023]
Abstract
Zika virus (ZIKV) is an arbovirus that caused widespread panic beginning in 2015 in northeastern Brazil due to the threatening link between infection and fetal abnormalities such as microcephaly, spontaneous abortions, and stillbirths. Since the epidemic began, the virus has been further investigated, unveiling that the long-term dangers of ZIKV infection go beyond fetal neurological impairment. Characterization of the active infection has proven difficult as only 20% of infected individuals are symptomatic. Additionally, ZIKV is often misdiagnosed due to serological cross-reactivity with similar flaviviruses such as dengue, yellow fever, and West Nile. To date, there is no approved vaccine or therapy against ZIKV, highlighting the urgent need to accurately identify active infection to help minimize the spread of the virus. Herein, we describe a highly specific and sensitive enzyme-linked immunosorbent assay to detect early active ZIKV using neutralizing human monoclonal antibodies isolated from infected patients in Brazil that do not cross-react with dengue viruses 1-4 and bind directly to a ZIKV immunodominant epitope. The calculated limits of detection of active ZIKV fall within the physiological ranges of the virus in human bodily fluids. This selective immunoassay creates the platform required for future translation toward a point-of-care assay for ZIKV, a necessity to diagnose active ZIKV in the remote regions of which it thrives.
Collapse
Affiliation(s)
- Devon
C. Pawley
- Department
of Biochemistry and Molecular Biology, Miller School of
Medicine and Department of Pathology, Miller School of Medicine, University of Miami, Miami, Florida 33136, United States
- Dr.
JT Macdonald Foundation Biomedical Nanotechnology Institute of the University of Miami, Miami, Florida 33136, United States
| | - Michael J. Ricciardi
- Department
of Biochemistry and Molecular Biology, Miller School of
Medicine and Department of Pathology, Miller School of Medicine, University of Miami, Miami, Florida 33136, United States
| | - Emre Dikici
- Department
of Biochemistry and Molecular Biology, Miller School of
Medicine and Department of Pathology, Miller School of Medicine, University of Miami, Miami, Florida 33136, United States
- Dr.
JT Macdonald Foundation Biomedical Nanotechnology Institute of the University of Miami, Miami, Florida 33136, United States
| | - Sapna K. Deo
- Department
of Biochemistry and Molecular Biology, Miller School of
Medicine and Department of Pathology, Miller School of Medicine, University of Miami, Miami, Florida 33136, United States
- Dr.
JT Macdonald Foundation Biomedical Nanotechnology Institute of the University of Miami, Miami, Florida 33136, United States
| | - Sylvia Daunert
- Department
of Biochemistry and Molecular Biology, Miller School of
Medicine and Department of Pathology, Miller School of Medicine, University of Miami, Miami, Florida 33136, United States
- Dr.
JT Macdonald Foundation Biomedical Nanotechnology Institute of the University of Miami, Miami, Florida 33136, United States
- University
of Miami Clinical and Translational Science Institute, Miami, Florida 33136, United States
| |
Collapse
|
37
|
Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil. Sci Rep 2019; 9:4494. [PMID: 30872672 PMCID: PMC6418238 DOI: 10.1038/s41598-019-40960-5] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 12/10/2018] [Indexed: 12/29/2022] Open
Abstract
The rapid spread of Zika virus (ZIKV) represents a global public health problem, especially in areas that harbor several mosquito species responsible for virus transmission, such as Brazil. In these areas, improvement in mosquito control needs to be a top priority, but mosquito viral surveillance occurs inefficiently in ZIKV-endemic countries. Quantitative reverse transcription PCR (qRT-PCR) is the gold standard for molecular diagnostic of ZIKV in both human and mosquito samples. However, the technique presents high cost and limitations for Point-of-care (POC) diagnostics, which hampers its application for a large number of samples in entomological surveillance programs. Here, we developed and validated a one-step reverse transcription LAMP (RT-LAMP) platform for detection of ZIKV in mosquito samples. The RT-LAMP assay was highly specific for ZIKV and up to 10,000 times more sensitive than qRT-PCR. Assay validation was performed using 60 samples from Aedes aegypti and Culex quinquefasciatus mosquitoes collected in Pernambuco State, Brazil, which is at the epicenter of the Zika epidemic. The RT-LAMP had a sensitivity of 100%, specificity of 91.18%, and overall accuracy of 95.24%. Thus, our POC diagnostics is a powerful and inexpensive tool to monitor ZIKV in mosquito populations and will allow developing countries to establish better control strategies for this devastating pathogen.
Collapse
|
38
|
Particle Diffusometry: An Optical Detection Method for Vibrio cholerae Presence in Environmental Water Samples. Sci Rep 2019; 9:1739. [PMID: 30741961 PMCID: PMC6370876 DOI: 10.1038/s41598-018-38056-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Accepted: 12/06/2018] [Indexed: 02/06/2023] Open
Abstract
There is a need for a rapid, robust, and sensitive biosensor to identify low concentrations of pathogens in their native sample matrix without enrichment or purification. Nucleic acid-based detection methods are widely accepted as the gold standard in diagnostics, but robust detection of low concentrations of pathogens remains challenging. Amplified nucleic acids produce more viscous solutions, which can be measured by combining these products with fluorescent particles and measuring the change in the particle diffusion coefficient using a technique known as particle diffusometry. Here, we utilize Vibrio cholerae (V. cholerae) as a proof-of-concept for our detection system due to its inherently low concentration in environmental water samples. We demonstrate that particle diffusometry can be used to detect down to 1 V. cholerae cell in molecular-grade water in 20 minutes and 10 V. cholerae cells in pond water in just 35 minutes in 25 µL reaction volumes. The detection limit in pond water is environmentally relevant and does not require any enrichment or sample preparation steps. Particle diffusometry is 10-fold more sensitive than current gold standard fluorescence detection of nucleic acid amplification. Therefore, this novel measurement technique is a promising approach to detect low levels of pathogens in their native environments.
Collapse
|
39
|
Saraf N, Villegas M, Willenberg BJ, Seal S. Multiplex Viral Detection Platform Based on a Aptamers-Integrated Microfluidic Channel. ACS OMEGA 2019; 4:2234-2240. [PMID: 30729227 PMCID: PMC6358057 DOI: 10.1021/acsomega.8b03277] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 01/11/2019] [Indexed: 05/02/2023]
Abstract
A polydimethylsiloxane-based microfluidic device has been developed for the multiplex detection of viral envelope proteins such as Zika and chikungunya on a single platform using aptamer-analyte interactions. The channel is integrated with microsized pillars that increase the surface area allowing more aptamers to attach to the incoming envelope protein molecules, thus increasing the overall sensitivity of the system. The working of the device depends on the formation of protein-mediated sandwich morphology that is obtained using an aptamer and aptamer-functionalized gold nanoparticle (AuNP) pair. The colorimetric signal is obtained upon introduction of silver reagents into the channel, which are selectively deposited on the AuNP surface, providing a gray contrast in the testing zone. The microfluidic channel approach successfully detected clinically relevant concentrations of Zika and chikungunya envelope proteins in phosphine-buffered saline (1 pM) and calf blood (100 pM) with high specificity using gold-decorated aptamers integrated in a microfluidic channel.
Collapse
Affiliation(s)
- Nileshi Saraf
- Advanced
Materials Processing and Analysis Centre, Department of
Materials Science and Engineering, Department of Internal Medicine, College of
Medicine, and Nanoscience Technology Centre, University
of Central Florida, Orlando, Florida 32827, United States
| | - Michael Villegas
- University
of Florida, Gainesville, Florida 32611, United
States
| | - Bradley Jay Willenberg
- Advanced
Materials Processing and Analysis Centre, Department of
Materials Science and Engineering, Department of Internal Medicine, College of
Medicine, and Nanoscience Technology Centre, University
of Central Florida, Orlando, Florida 32827, United States
| | - Sudipta Seal
- Advanced
Materials Processing and Analysis Centre, Department of
Materials Science and Engineering, Department of Internal Medicine, College of
Medicine, and Nanoscience Technology Centre, University
of Central Florida, Orlando, Florida 32827, United States
| |
Collapse
|
40
|
Tancharoen C, Sukjee W, Thepparit C, Jaimipuk T, Auewarakul P, Thitithanyanont A, Sangma C. Electrochemical Biosensor Based on Surface Imprinting for Zika Virus Detection in Serum. ACS Sens 2019; 4:69-75. [PMID: 30596236 DOI: 10.1021/acssensors.8b00885] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Zika virus (ZIKV) is a flavivirus that was first identified in 1947. Initially, the virus was of little concern for health authorities given there were very few casualties among those suffering an infection. As such, only limited studies were performed on ZIKV. Recently, the viral infection has been linked to microcephaly in infants, which has prompted a dramatic increase in scientific interest in ZIKV research, including methods to allow for rapid virus identification. In this work we report the development of a new type of ZIKV electrochemical biosensor based on surface imprinted polymers and graphene oxide composites. The biosensor was used to detect ZIKV by measuring changes in the electrical signal with changing virus concentrations in buffer and serum using standard electrochemical techniques. The detection limit of our method is similar to the detection limit of the real-time quantitative reverse transcription PCR method.
Collapse
Affiliation(s)
- Chompoonuch Tancharoen
- Department of Chemistry, Faculty of Science, Kasetsart University, Bangkok 10900, Thailand
| | - Wannisa Sukjee
- Department of Chemistry, Faculty of Science, Kasetsart University, Bangkok 10900, Thailand
| | - Chutima Thepparit
- Institute of Molecular Biosciences, Mahidol University, Bangkok, Nakhon Pathom 73170, Thailand
| | - Thitigun Jaimipuk
- Institute of Molecular Biosciences, Mahidol University, Bangkok, Nakhon Pathom 73170, Thailand
| | - Prasert Auewarakul
- Department of Microbiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| | - Arunee Thitithanyanont
- Department of Microbiology, Faculty of Science, Mahidol University, Bangkok 10400, Thailand
| | - Chak Sangma
- Department of Chemistry, Faculty of Science, Kasetsart University, Bangkok 10900, Thailand
- Center for Advanced Studies in Nanotechnology for Chemical, Food and Agricultural Industries, Kasetsart University Institute for Advanced Studies, Kasetsart University, Bangkok 10900, Thailand
| |
Collapse
|
41
|
Lyutyy TV. Dynamics and energy dissipation of a rigid dipole driven by the RF-field in a viscous fluid: Deterministic approach. THE EUROPEAN PHYSICAL JOURNAL. E, SOFT MATTER 2018; 41:142. [PMID: 30552543 DOI: 10.1140/epje/i2018-11756-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Accepted: 11/19/2018] [Indexed: 06/09/2023]
Abstract
The deterministic rotation of a ferromagnetic nanoparticle in a fluid is considered. The heating arising from viscous friction of a nanoparticle driven by circularly and linearly polarized alternating magnetic fields is investigated. Since the power loss of such fields depends on the character of the induced motion of a nanoparticle, all types of particle trajectories are described in detail. The dependences of the power loss on the alternating field parameters are determined. The optimal conditions for obtaining the maximum heating efficiency are discussed. The effect of heating enhancement by a static field is analyzed. The results obtained can be actual for the description of heating in the magnetic fluid hyperthermia cancer treatment, when the size of the particles used is a few tens of nanometers.
Collapse
Affiliation(s)
- T V Lyutyy
- Sumy State University, 2 Rimsky-Korsakov Street, UA-40007, Sumy, Ukraine.
| |
Collapse
|
42
|
Liao Y, Fan Z, Deng H, Yang Y, Lin J, Zhao Z, Tan Q, Li B, Huang X. Zika Virus Liquid Biopsy: A Dendritic Ru(bpy) 3 2+-Polymer-Amplified ECL Diagnosis Strategy Using a Drop of Blood. ACS CENTRAL SCIENCE 2018; 4:1403-1411. [PMID: 30410978 PMCID: PMC6202637 DOI: 10.1021/acscentsci.8b00471] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Indexed: 06/08/2023]
Abstract
Zika virus (ZIKV) is a mosquito-borne flavivirus that leads to devastating consequences for fetal development. However, accurate diagnosis of ZIKV is made difficult by the fact that most infected patients are asymptomatic or present with symptoms similar to those of other febrile illnesses. Thus, the development of a simple, accurate, highly sensitive, and reliable method for the biomedical analysis and diagnosis of ZIKV is needed. Herein, a novel ZIKV liquid biopsy system was constructed via a dendritic Ru(bpy)3 2+-polymer-amplified electro-chemiluminescence (ECL) strategy. This system accomplished amplification-free analysis of ZIKV using a drop of blood, and simultaneously achieved a high sensitivity of 500 copies and superior specificity. This strategy adopted the humoral biomarker as the diagnostic index, which greatly simplified the analysis process, and established a nondestructive detection mode. Furthermore, the performance index for biomedical analysis of clinical ZIKV samples was investigated, and the results indicated that the dendritic Ru(bpy)3 2+-polymer-amplified ECL strategy reliably responded to ZIKV from the body fluid (blood, saliva, and urine). Hence, this system suitably met the strict clinical requirements for ZIKV detection and thus has the potential to serve as a new paradigm for the biomedical analysis and diagnosis of ZIKV.
Collapse
Affiliation(s)
- Yuhui Liao
- Program
of Infection and Immunity, The Fifth Affiliated Hospital of Sun Yat-sen
University, Zhongshan School of Medicine, Sun Yat-sen University, Guangdong 510120, China
- Department
of Internal Medicine, Guangzhou Women and Children’s Medical
Center, Zhongshan School of Medicine, Sun
Yat-sen University, Guangdong 510120, China
- Key
Laboratory of Tropical Diseases Control, Ministry of Education, Sun Yat-sen University, Guangdong 510120, China
- Shenzhen
Key Laboratory of Pathogen and Immunity, State Key Discipline of Infectious
Disease, Shenzhen Third People’s
Hospital, Shenzhen 518112, China
| | - Zhijin Fan
- Program
of Infection and Immunity, The Fifth Affiliated Hospital of Sun Yat-sen
University, Zhongshan School of Medicine, Sun Yat-sen University, Guangdong 510120, China
| | - Huaping Deng
- Program
of Infection and Immunity, The Fifth Affiliated Hospital of Sun Yat-sen
University, Zhongshan School of Medicine, Sun Yat-sen University, Guangdong 510120, China
| | - Yang Yang
- Shenzhen
Key Laboratory of Pathogen and Immunity, State Key Discipline of Infectious
Disease, Shenzhen Third People’s
Hospital, Shenzhen 518112, China
| | - Jingyan Lin
- Shenzhen
Key Laboratory of Pathogen and Immunity, State Key Discipline of Infectious
Disease, Shenzhen Third People’s
Hospital, Shenzhen 518112, China
| | - Zhaoyan Zhao
- Program
of Infection and Immunity, The Fifth Affiliated Hospital of Sun Yat-sen
University, Zhongshan School of Medicine, Sun Yat-sen University, Guangdong 510120, China
- Key
Laboratory of Tropical Diseases Control, Ministry of Education, Sun Yat-sen University, Guangdong 510120, China
| | - Qingqin Tan
- Program
of Infection and Immunity, The Fifth Affiliated Hospital of Sun Yat-sen
University, Zhongshan School of Medicine, Sun Yat-sen University, Guangdong 510120, China
- Key
Laboratory of Tropical Diseases Control, Ministry of Education, Sun Yat-sen University, Guangdong 510120, China
| | - Bin Li
- Program
of Infection and Immunity, The Fifth Affiliated Hospital of Sun Yat-sen
University, Zhongshan School of Medicine, Sun Yat-sen University, Guangdong 510120, China
- Key
Laboratory of Tropical Diseases Control, Ministry of Education, Sun Yat-sen University, Guangdong 510120, China
| | - Xi Huang
- Program
of Infection and Immunity, The Fifth Affiliated Hospital of Sun Yat-sen
University, Zhongshan School of Medicine, Sun Yat-sen University, Guangdong 510120, China
- Department
of Internal Medicine, Guangzhou Women and Children’s Medical
Center, Zhongshan School of Medicine, Sun
Yat-sen University, Guangdong 510120, China
- Sino-French
Hoffmann Institute of Immunology, College of Basic Medical Science, Guangzhou Medical University, Guangzhou 510000, China
- Key
Laboratory of Tropical Diseases Control, Ministry of Education, Sun Yat-sen University, Guangdong 510120, China
- The
First Hospital of Jilin University, Changchun 130021, China
- Shenzhen
Key Laboratory of Pathogen and Immunity, State Key Discipline of Infectious
Disease, Shenzhen Third People’s
Hospital, Shenzhen 518112, China
| |
Collapse
|
43
|
Assay Challenges for Emerging Infectious Diseases: The Zika Experience. Vaccines (Basel) 2018; 6:vaccines6040070. [PMID: 30279372 PMCID: PMC6313918 DOI: 10.3390/vaccines6040070] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 09/24/2018] [Accepted: 09/26/2018] [Indexed: 01/07/2023] Open
Abstract
From the perspective of vaccine development, it is imperative to accurately diagnose target infections in order to exclude subjects with prior exposure from evaluations of vaccine effectiveness, to track incident infection during the course of a clinical trial and to differentiate immune reactions due to natural infections from responses that are vaccine related. When vaccine development is accelerated to a rapid pace in response to emerging infectious disease threats, the challenges to develop such diagnostic tools is even greater. This was observed through the recent expansion of Zika virus infections into the Western Hemisphere in 2014⁻2017. When initial Zika vaccine clinical trials were being designed and launched in response to the outbreak, there were no standardized sets of viral and immunological assays, and no approved diagnostic tests for Zika virus infection. The diagnosis of Zika virus infection is still an area of active research and development on many fronts. Here we review emerging infectious disease vaccine clinical assay development and trial execution with a special focus on the state of Zika virus clinical assays and diagnostics.
Collapse
|
44
|
Simpler, Faster, and Sensitive Zika Virus Assay Using Smartphone Detection of Loop-mediated Isothermal Amplification on Paper Microfluidic Chips. Sci Rep 2018; 8:12438. [PMID: 30127503 PMCID: PMC6102244 DOI: 10.1038/s41598-018-30797-9] [Citation(s) in RCA: 116] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Accepted: 07/30/2018] [Indexed: 11/08/2022] Open
Abstract
The recent Zika virus (ZIKV) outbreak has prompted the need for field-ready diagnostics that are rapid, easy-to-use, handheld, and disposable while providing extreme sensitivity and specificity. To meet this demand, we developed a wax-printed paper microfluidic chip utilizing reverse transcription loop-mediated isothermal amplification (RT-LAMP). The developed simple and sensitive ZIKV assay was demonstrated using undiluted tap water, human urine, and diluted (10%) human blood plasma. Paper type, pore size, and channel dimension of various paper microfluidic chips were investigated and optimized to ensure proper filtration of direct-use biological samples (tap water, urine, and plasma) during capillary action-driven flow. Once ZIKV RNA has flowed and reached to a detection area of the paper microfluidic chip, it was excised for the addition of an RT-LAMP mixture with a pH indicator, then placed on a hot plate at 68 °C. Visible color changes from successful amplification were observed in 15 minutes and quantified by smartphone imaging. The limit of detection was as low as 1 copy/μL. The developed platform can also be used for identifying other flaviviruses, such as Chikungunya virus (CHIKV) and Dengue virus (DENV), and potentially other quickly transmitted virus pathogens, towards field-based diagnostics.
Collapse
|
45
|
Pashchenko O, Shelby T, Banerjee T, Santra S. A Comparison of Optical, Electrochemical, Magnetic, and Colorimetric Point-of-Care Biosensors for Infectious Disease Diagnosis. ACS Infect Dis 2018; 4:1162-1178. [PMID: 29860830 PMCID: PMC6736529 DOI: 10.1021/acsinfecdis.8b00023] [Citation(s) in RCA: 121] [Impact Index Per Article: 20.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Each year, infectious diseases are responsible for millions of deaths, most of which occur in the rural areas of developing countries. Many of the infectious disease diagnostic tools used today require a great deal of time, a laboratory setting, and trained personnel. Due to this, the need for effective point-of-care (POC) diagnostic tools is greatly increasing with an emphasis on affordability, portability, sensitivity, specificity, timeliness, and ease of use. In this Review, we discuss the various diagnostic modalities that have been utilized toward this end and are being further developed to create POC diagnostic technologies, and we focus on potential effectiveness in resource-limited settings. The main modalities discussed herein are optical-, electrochemical-, magnetic-, and colorimetric-based modalities utilized in diagnostic technologies for infectious diseases. Each of these modalities feature pros and cons when considering application in POC settings but, overall, reveal a promising outlook for the future of this field of technological development.
Collapse
Affiliation(s)
- Oleksandra Pashchenko
- Department of Chemistry, Pittsburg State University, 1701 South Broadway Street, Pittsburg, Kansas, 66762
| | - Tyler Shelby
- Department of Chemistry, Pittsburg State University, 1701 South Broadway Street, Pittsburg, Kansas, 66762
| | - Tuhina Banerjee
- Department of Chemistry, Pittsburg State University, 1701 South Broadway Street, Pittsburg, Kansas, 66762
| | - Santimukul Santra
- Department of Chemistry, Pittsburg State University, 1701 South Broadway Street, Pittsburg, Kansas, 66762
| |
Collapse
|
46
|
Gandasegui J, Fernández-Soto P, Dacal E, Rodríguez E, Saugar JM, Yepes E, Aznar-Ruiz-de-Alegría ML, Espasa M, Ninda A, Bocanegra C, Salvador F, Sulleiro E, Moreno M, Vicente B, López-Abán J, Muro A. Field and laboratory comparative evaluation of a LAMP assay for the diagnosis of urogenital schistosomiasis in Cubal, Central Angola. Trop Med Int Health 2018; 23:992-1001. [PMID: 29920859 DOI: 10.1111/tmi.13117] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVE To evaluate the performance of Rapid-Heat LAMPellet assay in field conditions for diagnosis of urogenital schistosomiasis in an endemic area in Cubal, Angola, and to assess the reproducibility in a reference laboratory. METHODS A total of 172 urine samples from school-age children were tested for microhaematuria, microscopic detection of Schistosoma haematobium eggs and LAMP for DNA detection. Urine samples were stored in a basic equipped laboratory. Field-LAMP tests were performed with and without prior DNA extraction from urine samples, and the results were read by turbidity and by colour change. When field procedures were finished, samples were sent to a reference laboratory to be reanalysed by LAMP. RESULTS A total of 83 of 172 (48.3%) were positive for microhaematuria, 87/172 (50.6%) were microscopy-positive for S. haematobium eggs detection, and 127/172 (73.8%) showed LAMP-positive results for detecting S. haematobium using purified DNA and 109/172 (63.4%) without prior DNA extraction. MacNemar's test showed a statistical significant relation between LAMP results and microscopy-detected S. haematobium infections and microhaematuria (P < 0.001 in both cases), respectively. When samples of purified DNA were reanalysed in a reference laboratory in Spain using the same LAMP methodology, the overall reproducibility achieved 72.1%. CONCLUSIONS The ease of use, simplicity and feasibility demonstrated by LAMP assay in field conditions together with the acceptable level of reproducibility achieved in a reference laboratory support the use of LAMP assay as an effective test for molecular diagnosis of urogenital schistosomiasis in endemic remote areas.
Collapse
Affiliation(s)
- Javier Gandasegui
- Infectious and Tropical Diseases Research Group (e-INTRO), Faculty of Pharmacy, Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), University of Salamanca, Salamanca, Spain
| | - Pedro Fernández-Soto
- Infectious and Tropical Diseases Research Group (e-INTRO), Faculty of Pharmacy, Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), University of Salamanca, Salamanca, Spain
| | - Elena Dacal
- Department of Parasitology, National Centre for Microbiology, Institute of Health Carlos III, Majadahonda, Madrid, Spain
| | - Esperanza Rodríguez
- Department of Parasitology, National Centre for Microbiology, Institute of Health Carlos III, Majadahonda, Madrid, Spain
| | - José María Saugar
- Department of Parasitology, National Centre for Microbiology, Institute of Health Carlos III, Majadahonda, Madrid, Spain
| | - Edward Yepes
- Infectious and Tropical Diseases Research Group (e-INTRO), Faculty of Pharmacy, Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), University of Salamanca, Salamanca, Spain
| | | | - Mateu Espasa
- Microbiology Department, University Hospital Vall d'Hebron, PROSICS Barcelona, Barcelona, Spain
| | | | - Cristina Bocanegra
- Special Program for Infectious Diseases Vall d'Hebron-Drassanes, PROSICS Barcelona, Barcelona, Spain
| | - Fernando Salvador
- Infectious Diseases Department, Vall d'Hebron University Hospital, PROSICS Barcelona, Barcelona, Spain
| | - Elena Sulleiro
- Microbiology Department, University Hospital Vall d'Hebron, PROSICS Barcelona, Barcelona, Spain
| | | | - Belén Vicente
- Infectious and Tropical Diseases Research Group (e-INTRO), Faculty of Pharmacy, Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), University of Salamanca, Salamanca, Spain
| | - Julio López-Abán
- Infectious and Tropical Diseases Research Group (e-INTRO), Faculty of Pharmacy, Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), University of Salamanca, Salamanca, Spain
| | - Antonio Muro
- Infectious and Tropical Diseases Research Group (e-INTRO), Faculty of Pharmacy, Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), University of Salamanca, Salamanca, Spain
| |
Collapse
|
47
|
Tian B, Liao X, Svedlindh P, Strömberg M, Wetterskog E. Ferromagnetic Resonance Biosensor for Homogeneous and Volumetric Detection of DNA. ACS Sens 2018; 3:1093-1101. [PMID: 29847920 DOI: 10.1021/acssensors.8b00048] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
The ability to detect and analyze the state of magnetic labels with high sensitivity is of crucial importance for developing magnetic biosensors. In this work, we demonstrate, for the first time, a ferromagnetic resonance (FMR) based homogeneous and volumetric biosensor for magnetic label detection. Two different isothermal amplification methods, i.e., rolling circle amplification (RCA) and loop-mediated isothermal amplification (LAMP), are adopted and combined with a standard electron paramagnetic resonance (EPR) spectrometer for FMR biosensing. For the RCA-based FMR biosensor, binding of RCA products of a synthetic Vibrio cholerae target DNA sequence gives rise to the formation of aggregates of magnetic nanoparticles. Immobilization of nanoparticles within the aggregates leads to a decrease of the net anisotropy of the system and a concomitant increase of the resonance field. A limit of detection of 1 pM is obtained with a linear detection range between 7.8 and 250 pM. For the LAMP-based sensing, a synthetic Zika virus target oligonucleotide is amplified and detected in 20% serum samples. Immobilization of magnetic nanoparticles is induced by their coprecipitation with Mg2P2O7 (a byproduct of LAMP) and provides a detection sensitivity of 100 aM. The fast measurement, high sensitivity, and miniaturization potential of the proposed FMR biosensing technology makes it a promising candidate for designing future point-of-care devices.
Collapse
Affiliation(s)
- Bo Tian
- Department of Engineering Sciences, Uppsala University, The Ångström Laboratory, Box 534, SE-751 21 Uppsala, Sweden
| | - Xiaoqi Liao
- Department of Engineering Sciences, Uppsala University, The Ångström Laboratory, Box 534, SE-751 21 Uppsala, Sweden
| | - Peter Svedlindh
- Department of Engineering Sciences, Uppsala University, The Ångström Laboratory, Box 534, SE-751 21 Uppsala, Sweden
| | - Mattias Strömberg
- Department of Engineering Sciences, Uppsala University, The Ångström Laboratory, Box 534, SE-751 21 Uppsala, Sweden
| | - Erik Wetterskog
- Department of Engineering Sciences, Uppsala University, The Ångström Laboratory, Box 534, SE-751 21 Uppsala, Sweden
| |
Collapse
|
48
|
Wu W, Fan H, Lian X, Zhou J, Zhang T. Aligner-mediated cleavage-triggered exponential amplification for sensitive detection of nucleic acids. Talanta 2018; 185:141-145. [PMID: 29759180 DOI: 10.1016/j.talanta.2018.03.067] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 03/14/2018] [Accepted: 03/22/2018] [Indexed: 10/17/2022]
Abstract
Exponential amplification reaction (EXPAR), as a simple and high sensitive method, holds great promise in nucleic acids detection. One major challenge in EXPAR is the generation of trigger DNA with a definite 3'-end, which now relies on fingerprinting technology. However, the requirement of different endonucleases for varying target sequences and two head-to-head recognition sites in double stranded DNA, as well as the confinement of trigger DNA's 3'-end to be near/within the recognition site, usually subject EXPAR to compromised universality and/or repeated matching of reaction conditions. Herein, we report a simple and universal method for high sensitive detection of nucleic acids, termed aligner-mediated cleavage-triggered exponential amplification (AMCEA). The aligner-mediated cleavage (AMC) needs only one nicking endonuclease and can make a break at any site of choice in a programmable way. Thus, the 3'-end of target DNA can be easily redefined as required, a key step for initiating the amplification reaction. This capability endows the proposed AMCEA with excellent universality and simplicity. Moreover, it is sensitive and specific, with a detection limit at amol level, a broad dynamic range of 5~6 orders of magnitude and the ability to distinguish single nucleotide mutation. Experiments performed with human serum indicate that AMCEA is compatible with the complex biological sample, and thus has the potentials for practical applications.
Collapse
Affiliation(s)
- Wanghua Wu
- Research Center for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, PR China
| | - Hongliang Fan
- Department of Environmental Medicine, Institute of Hygiene, Zhejiang Academy of Medical Sciences, Hangzhou 310013, PR China
| | - Xiang Lian
- Research Center for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, PR China
| | - Jianguang Zhou
- Research Center for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, PR China
| | - Tao Zhang
- Research Center for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, PR China.
| |
Collapse
|
49
|
Yaren O, Alto BW, Bradley KM, Moussatche P, Glushakova L, Benner SA. Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1. J Vis Exp 2018. [PMID: 29608170 DOI: 10.3791/57051] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Zika, dengue, and chikungunya viruses are transmitted by mosquitoes, causing diseases with similar patient symptoms. However, they have different downstream patient-to-patient transmission potentials, and require very different patient treatments. Thus, recent Zika outbreaks make it urgent to develop tools that rapidly discriminate these viruses in patients and trapped mosquitoes, to select the correct patient treatment, and to understand and manage their epidemiology in real time. Unfortunately, current diagnostic tests, including those receiving 2016 emergency use authorizations and fast-track status, detect viral RNA by reverse transcription polymerase chain reaction (RT-PCR), which requires instrumentation, trained users, and considerable sample preparation. Thus, they must be sent to "approved" reference laboratories, requiring time. Indeed, in August 2016, the Center for Disease Control (CDC) was asking pregnant women who had been bitten by a mosquito and developed a Zika-indicating rash to wait an unacceptable 2 to 4 weeks before learning whether they were infected. We very much need tests that can be done on site, with few resources, and by trained but not necessarily licensed personnel. This video demonstrates an assay that meets these specifications, working with urine or serum (for patients) or crushed mosquito carcasses (for environmental surveillance), all without much sample preparation. Mosquito carcasses are captured on paper carrying quaternary ammonium groups (Q-paper) followed by ammonia treatment to manage biohazards. These are then directly, without RNA isolation, put into assay tubes containing freeze-dried reagents that need no chain of refrigeration. A modified form of reverse transcription loop-mediated isothermal amplification with target-specific fluorescently tagged displaceable probes produces readout, in 30 min, as a three-color fluorescence signal. This is visualized with a handheld, battery-powered device with an orange filter. Forward contamination is prevented with sealed tubes, and the use of thermolabile uracil DNA glycosylase (UDG) in the presence of dUTP in the amplification mixture.
Collapse
Affiliation(s)
- Ozlem Yaren
- Foundation for Applied Molecular Evolution (FfAME)
| | - Barry W Alto
- Florida Medical Entomology Laboratory, University of Florida
| | | | | | | | - Steven A Benner
- Foundation for Applied Molecular Evolution (FfAME); Firebird Biomolecular Sciences LLC;
| |
Collapse
|
50
|
Wong YP, Othman S, Lau YL, Radu S, Chee HY. Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organisms. J Appl Microbiol 2018; 124:626-643. [PMID: 29165905 PMCID: PMC7167136 DOI: 10.1111/jam.13647] [Citation(s) in RCA: 349] [Impact Index Per Article: 58.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 11/09/2017] [Accepted: 11/13/2017] [Indexed: 12/11/2022]
Abstract
Loop‐mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. (2000Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro‐organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro‐organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real‐time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro‐organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease.
Collapse
Affiliation(s)
- Y-P Wong
- Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Malaysia
| | - S Othman
- Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Malaysia
| | - Y-L Lau
- Department of Parasitology, Faculty of Medicine, Tropical Infectious Diseases Research and Education Centre (TIDREC), University of Malaya, Kuala Lumpur, Malaysia
| | - S Radu
- Centre of Excellence for Food Safety Research (FOSREC), Faculty of Food Science and Technology, Universiti Putra Malaysia, Serdang, Malaysia
| | - H-Y Chee
- Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Malaysia
| |
Collapse
|