1
|
Santos DJAD, Oliveira TRD, Araújo GMD, Pott-Junior H, Melendez ME, Sabino EC, Leite OD, Faria RC. An electrochemical genomagnetic assay for detection of SARS-CoV-2 and Influenza A viruses in saliva. Biosens Bioelectron 2024; 255:116210. [PMID: 38537427 DOI: 10.1016/j.bios.2024.116210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 02/28/2024] [Accepted: 03/11/2024] [Indexed: 04/15/2024]
Abstract
Viral respiratory infections represent a major threat to the population's health globally. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causes COVID-19 disease and in some cases the symptoms can be confused with Influenza disease caused by the Influenza A viruses. A simple, fast, and selective assay capable of identifying the etiological agent and differentiating the diseases is essential to provide the correct clinical management to the patient. Herein, we described the development of a genomagnetic assay for the selective capture of viral RNA from SARS-CoV-2 and Influenza A viruses in saliva samples and employing a simple disposable electrochemical device for gene detection and quantification. The proposed method showed excellent performance detecting RNA of SARS-CoV-2 and Influenza A viruses, with a limit of detection (LoD) and limit of quantification (LoQ) of 5.0 fmol L-1 and 8.6 fmol L-1 for SARS-CoV-2, and 1.0 fmol L-1 and 108.9 fmol L-1 for Influenza, respectively. The genomagnetic assay was employed to evaluate the presence of the viruses in 36 saliva samples and the results presented similar responses to those obtained by the real-time reverse transcription-polymerase chain reaction (RT-PCR), demonstrating the reliability and capability of a method as an alternative for the diagnosis of COVID-19 and Influenza with point-of-care capabilities.
Collapse
Affiliation(s)
| | | | | | - Henrique Pott-Junior
- Department of Medicine, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil
| | | | - Ester Cerdeira Sabino
- Institute of Tropical Medicine, Faculty of Medicine, University of São Paulo, São Paulo, SP, 05403-000, Brazil
| | - Oldair Donizeti Leite
- Department of Chemistry, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil; Federal Technological University of Paraná, Campus Medianeira, Medianeira, PR, 85884-000, Brazil.
| | - Ronaldo Censi Faria
- Department of Chemistry, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil.
| |
Collapse
|
2
|
Ming P, Li J, Yang L, Yu Y, Tang L, Zhou H, Zhang ZY, Zhang GJ. A Drug Molecule-Modified Graphene Field-Effect Transistor Nanosensor for Rapid, Label-Free, and Ultrasensitive Detection of Estrogen Receptor α Protein. Anal Chem 2024; 96:3454-3461. [PMID: 38359782 DOI: 10.1021/acs.analchem.3c04809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
Estrogen receptor α (ERα) is an important biomarker in breast cancer diagnosis and treatment. Sensitive and accurate detection of ERα protein expression is crucial in guiding selection of an appropriate therapeutic strategy to improve the effectiveness and prognosis of breast cancer treatment. Herein, we report a liquid-gated graphene field-effect transistor (FET) biosensor that enables rapid, sensitive, and label-free detection of the ERα protein by employing a novel drug molecule as a capture probe. The drug molecule was synthesized and subsequently immobilized onto the sensing surface of the fabricated graphene FET, which was able to distinguish the ERα-positive from the ERα-negative protein. The developed sensor not only demonstrated a low detection limit (LOD: 2.62 fM) but also achieved a fast response to ERα protein samples within 30 min. Moreover, depending on the relationship between the change of dirac point and the ERα protein concentrations, the dissociation constant (Kd) was estimated to be 7.35 ± 0.06 pM, indicating that the drug probe-modified graphene FET had a good affinity with ERα protein. The nanosensor was able to analyze ERα proteins from 36 cell samples lysates. These results show that the graphene FET sensor was able to differentiate between ERα-positive and ERα-negative cells, indicating a promising biosensor for the ultrasensitive and rapid detection of ERα protein without antibody labeling.
Collapse
Affiliation(s)
- Pinghong Ming
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 16 Huangjia Lake West Road, Wuhan 430065, P. R. China
- Department of Clinical Laboratory, The People's Hospital of Longhua, Shenzhen 518109, P. R. China
| | - Jiahao Li
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 16 Huangjia Lake West Road, Wuhan 430065, P. R. China
| | - Lu Yang
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou 646000, P. R. China
| | - Yi Yu
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 16 Huangjia Lake West Road, Wuhan 430065, P. R. China
| | - Lina Tang
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 16 Huangjia Lake West Road, Wuhan 430065, P. R. China
| | - Haibing Zhou
- Hubei Provincial Key Laboratory of Developmentally Originated Disease, State Key Laboratory of Virology, Wuhan University School of Pharmaceutical Sciences, Wuhan 430071, P. R. China
| | - Zhi-Yong Zhang
- Key Laboratory for the Physics and Chemistry of Nanodevices and Center for Carbon-based Electronics, School of Electronics, Peking University, Beijing 100871, P. R. China
| | - Guo-Jun Zhang
- School of Laboratory Medicine, Hubei University of Chinese Medicine, 16 Huangjia Lake West Road, Wuhan 430065, P. R. China
- Hubei Shizhen Laboratory, Hubei University of Chinese Medicine, 16 Huangjia Lake West Road, Wuhan 430065, P. R. China
| |
Collapse
|
3
|
Zhang Y, Ma W, Li N, Xu Y, Qi N, Yang M, Hou C, Huo D. Microswimmer-Assisted Dual-Signal Sensor for Multiple Targets in Whole Blood. Anal Chem 2023; 95:17256-17262. [PMID: 37963284 DOI: 10.1021/acs.analchem.3c03125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2023]
Abstract
Accurate detection of biomarkers in whole blood is an important aspect of diagnostic testing but remains a challenge due to various interferences. However, using a self-calibrating two-signal strategy offers a solution that can overcome interference caused by experimental and environmental factors. Here, we proposed a novel microswimmer {methylene blue (MB)@ZIF-90@aptamer-HER2/3,3',5,5'-tetramethylbenzidine (TMB)@ZIF-90@aptamer-ER}-dual-signal (electrochemical and fluorescence) homogeneous sensor based on functionalized ZIF nanomaterials for one-step simultaneous detection of human epidermal growth factor receptor-2 (HER2) and estrogen receptor (ER) in whole blood. The proposed one-step ZIF-90 synthesis encapsulates TMB and MB with dual-signal properties. HER2 and ER aptamers adsorbed on MB@ZIF-90/TMB@ZIF-90 function as the gate switches. The microswimmer targets the HER2 and ER with adenosine triphosphate (ATP)-driven motion. When targets are present, aptamers dissociate and reduce the microswimmer's surface negative charge. The microswimmer undergoes attack and decomposition by swimming ATP due to the strong coordination force between ATP and Zn2+, leading to the release of MB and TMB. The negative charges on the surface of indium tin oxide enrich MB and TMB with positive charges, thereby increasing the intensities of electrochemical and fluorescence signals. The detection process was completed within 40 min, and the detection limits for ER and HER2 were 8.1 and 5.7 fg/mL respectively, with a linear range of 0.25-20 pg/mL.
Collapse
Affiliation(s)
- Ya Zhang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Wenhao Ma
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Ning Li
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Ying Xu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Na Qi
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Mei Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
- National Facility for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
- Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, PR China
| |
Collapse
|
4
|
Felici E, Regiart MD, Pereira SV, Ortega FG, Angnes L, Messina GA, Fernández-Baldo MA. Microfluidic Platform Integrated with Carbon Nanofibers-Decorated Gold Nanoporous Sensing Device for Serum PSA Quantification. BIOSENSORS 2023; 13:390. [PMID: 36979602 PMCID: PMC10046291 DOI: 10.3390/bios13030390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 03/09/2023] [Accepted: 03/14/2023] [Indexed: 06/18/2023]
Abstract
Prostate cancer is a disease with a high incidence and mortality rate in men worldwide. Serum prostate-specific antigens (PSA) are the main circulating biomarker for this disease in clinical practices. In this work, we present a portable and reusable microfluidic device for PSA quantification. This device comprises a polymethyl methacrylate microfluidic platform coupled with electrochemical detection. The platinum working microelectrode was positioned in the outflow region of the microchannel and was modified with carbon nanofibers (CNF)-decorated gold nanoporous (GNP) structures by the dynamic hydrogen bubble template method, through the simultaneous electrodeposition of metal precursors in the presence of CNF. CNF/GNP structures exhibit attractive properties, such as a large surface to volume ratio, which increases the antibody's immobilization capacity and the electroactive area. CNFs/GNP structures were characterized by scanning electron microscopy, energy dispersive spectrometry, and cyclic voltammetry. Anti-PSA antibodies and HRP were employed for the immune-electrochemical reaction. The detection limit for the device was 5 pg mL-1, with a linear range from 0.01 to 50 ng mL-1. The coefficients of variation within and between assays were lower than 4.40%, and 6.15%, respectively. Additionally, its clinical performance was tested in serum from 30 prostate cancer patients. This novel device was a sensitive, selective, portable, and reusable tool for the serological diagnosis and monitoring of prostate cancer.
Collapse
Affiliation(s)
- Emiliano Felici
- Facultad de Química, Bioquímica y Farmacia, Instituto de Química de San Luis, INQUISAL (UNSL—CONICET), Universidad Nacional de San Luis, Chacabuco 917, San Luis D5700BWS, Argentina
| | - Matías D. Regiart
- Facultad de Química, Bioquímica y Farmacia, Instituto de Química de San Luis, INQUISAL (UNSL—CONICET), Universidad Nacional de San Luis, Chacabuco 917, San Luis D5700BWS, Argentina
| | - Sirley V. Pereira
- Facultad de Química, Bioquímica y Farmacia, Instituto de Química de San Luis, INQUISAL (UNSL—CONICET), Universidad Nacional de San Luis, Chacabuco 917, San Luis D5700BWS, Argentina
| | - Francisco G. Ortega
- GENYO, Centre for Genomics and Oncological Research, Pfizer/University of Granada/Andalusian Regional Government PTS, Granada, Avenida de la Ilustración, 114, 18016 Granada, Spain
- IBS Granada, Institute of Biomedical Research, Avenida de Madrid 15, 18012 Granada, Spain
- UGC Cartuja, Distrito Sanitario Granada Metropolitano. Calle Joaquina Eguaras, 2, 18013 Granada, Spain
| | - Lúcio Angnes
- Laboratório de Automação e Instrumentação Analítica, Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Professor Lineu Prestes 748, São Paulo 05508-000, Brazil
| | - Germán A. Messina
- Facultad de Química, Bioquímica y Farmacia, Instituto de Química de San Luis, INQUISAL (UNSL—CONICET), Universidad Nacional de San Luis, Chacabuco 917, San Luis D5700BWS, Argentina
| | - Martín A. Fernández-Baldo
- Facultad de Química, Bioquímica y Farmacia, Instituto de Química de San Luis, INQUISAL (UNSL—CONICET), Universidad Nacional de San Luis, Chacabuco 917, San Luis D5700BWS, Argentina
| |
Collapse
|
5
|
Hernández-Rodríguez JF, López MÁ, Rojas D, Escarpa A. Digital manufacturing for accelerating organ-on-a-chip dissemination and electrochemical biosensing integration. LAB ON A CHIP 2022; 22:4805-4821. [PMID: 36342332 DOI: 10.1039/d2lc00499b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Organ on-a-chip (OoC) is a promising technology that aims to recapitulate human body pathophysiology in a more precise way to advance in drug development and complex disease understanding. However, the presence of OoC in biological laboratories is still limited and mainly restricted to laboratories with access to cleanroom facilities. Besides, the current analytical methods employed to extract information from the organ models are endpoint and post facto assays which makes it difficult to ensure that during the biological experiment the cell microenvironment, cellular functionality and behaviour are controlled. Hence, the integration of real-time biosensors is highly needed and requested by the OoC end-user community to provide insight into organ function and responses to stimuli. In this context, electrochemical sensors stand out due to their advantageous features like miniaturization capabilities, ease of use, automatization and high sensitivity and selectivity. Electrochemical sensors have been already successfully miniaturized and employed in other fields such as wearables and point-of-care devices. We have identified that the explanation for this issue may be, to a large extent, the accessibility to microfabrication technologies. These fields employ preferably digital manufacturing (DM), which is a more accessible microfabrication approach regardless of funding and facilities. Therefore, we envision that a paradigm shift in microfabrication that adopts DM instead of the dominating soft lithography for the in-lab microfabrication of OoC devices will contribute to the dissemination of the field and integration of the promising real-time sensing.
Collapse
Affiliation(s)
- Juan F Hernández-Rodríguez
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Madrid, Spain.
| | - Miguel Ángel López
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Madrid, Spain.
- Chemical Engineering and Chemical Research Institute "Andres M. Del Río", University of Alcalá, Madrid, Spain
| | - Daniel Rojas
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Madrid, Spain.
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Madrid, Spain.
- Chemical Engineering and Chemical Research Institute "Andres M. Del Río", University of Alcalá, Madrid, Spain
| |
Collapse
|
6
|
Zhang X, Zhang Z, Xue X, Fan T, Tan C, Liu F, Tan Y, Jiang Y. PROTAC Degrader of Estrogen Receptor α Targeting DNA-Binding Domain in Breast Cancer. ACS Pharmacol Transl Sci 2022; 5:1109-1118. [PMID: 36407946 PMCID: PMC9667539 DOI: 10.1021/acsptsci.2c00109] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Indexed: 12/24/2022]
Abstract
PROteolysis-TArgeting Chimeras (PROTACs) are a powerful class of drugs that selectively degrade the proteins of interest (POIs) through cellular ubiquitination mechanisms. Estrogen receptor α (ERα) plays a vital role in the pathogenesis and treatment of breast cancer. In this work, the DNA-binding domain (DBD) of ERα was selected as the target to avoid drug resistance caused by the ligand-binding domain (LBD) of ERα. The estrogen response element (ERE), a natural DNA sequence binding with DBD of ERα, was chosen as a recognized unit of PROTAC. Therefore, we designed a nucleic acid-conjugated PROTAC, ERE-PROTAC, via a click reaction, in which the ERE sequence recruits ERα and the typical small molecule VH032 recruits the von Hippel-Lindau (VHL) E3 ligase. The proposed ERE-PROTAC showed to efficiently and reversibly degrade ERα in different breast cancer cells by targeting the DBD, indicating its potential to overcome the current resistance caused by LBD mutations.
Collapse
Affiliation(s)
| | | | - Xiaoqi Xue
- State Key Laboratory of Chemical
Oncogenomics, Key Laboratory of Chemical Biology, Tsinghua Shenzhen International Graduate School Tsinghua University, Shenzhen 518055, China
| | - Tingting Fan
- State Key Laboratory of Chemical
Oncogenomics, Key Laboratory of Chemical Biology, Tsinghua Shenzhen International Graduate School Tsinghua University, Shenzhen 518055, China
| | - Chunyan Tan
- State Key Laboratory of Chemical
Oncogenomics, Key Laboratory of Chemical Biology, Tsinghua Shenzhen International Graduate School Tsinghua University, Shenzhen 518055, China
| | - Feng Liu
- State Key Laboratory of Chemical
Oncogenomics, Key Laboratory of Chemical Biology, Tsinghua Shenzhen International Graduate School Tsinghua University, Shenzhen 518055, China
| | - Ying Tan
- State Key Laboratory of Chemical
Oncogenomics, Key Laboratory of Chemical Biology, Tsinghua Shenzhen International Graduate School Tsinghua University, Shenzhen 518055, China
| | - Yuyang Jiang
- State Key Laboratory of Chemical
Oncogenomics, Key Laboratory of Chemical Biology, Tsinghua Shenzhen International Graduate School Tsinghua University, Shenzhen 518055, China
| |
Collapse
|
7
|
Zhao P, Liu Y, Chen Y, Yang M, Zhao S, Qi N, Wang Y, Huo D, Hou C. Hemin-Functionalized Microfluidic Chip with Dual-Electric Signal Outputs for Accurate Determination of Uric Acid. ACS APPLIED MATERIALS & INTERFACES 2022; 14:41369-41378. [PMID: 36048632 DOI: 10.1021/acsami.2c07660] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Herein, we develop a hemin-functionalized microfluidic chip with dual-electric signal outputs for accurate determination of uric acid (UA). Hemin is designed as the catalyst, which could trigger a built-in reference signal. Carbon nanotube (CNT) and alkalinized titanium carbide (alk-Ti3C2Tx) are used as attachment substrates to strengthen the signal. Benefiting from the synergistic action of hemin, CNT, and alk-Ti3C2Tx, the hybrid functionalized sensor shows prominent electrochemical capacity, desirable catalytic activity, and unique built-in signal ability. Through density functional theory calculations, the structure-reactivity relationship and possible signal output mechanism are deeply investigated. The functionalized sensor is further integrated into a microfluidic chip to prepare a portable electrochemical sensing platform, in which multiple sample processing steps including primary filtration, target enrichment, and reliable analysis can be conducted step-by-step. Based on the abovementioned designs, the developed functionalized microfluidic platform presents desirable performance in UA determination with a detection limit of 0.41 μM. Furthermore, it is capable of accurately detecting UA in urine samples, providing a promising idea for biomolecule monitoring.
Collapse
Affiliation(s)
- Peng Zhao
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Yiyi Liu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Yuanyuan Chen
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Mei Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Shixian Zhao
- Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, PR China
- Chongqing Engineering and Technology Research Center of Intelligent Rehabilitation and Eldercare, Chongqing City Management College, Chongqing 401331, China
| | - Na Qi
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Yongzhong Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
- Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, PR China
| |
Collapse
|
8
|
Tiwari A, Chaskar J, Ali A, Arivarasan VK, Chaskar AC. Role of Sensor Technology in Detection of the Breast Cancer. BIONANOSCIENCE 2022. [DOI: 10.1007/s12668-021-00921-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
9
|
Frankman ZD, Jiang L, Schroeder JA, Zohar Y. Application of Microfluidic Systems for Breast Cancer Research. MICROMACHINES 2022; 13:152. [PMID: 35208277 PMCID: PMC8877872 DOI: 10.3390/mi13020152] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 01/11/2022] [Accepted: 01/17/2022] [Indexed: 02/06/2023]
Abstract
Cancer is a disease in which cells in the body grow out of control; breast cancer is the most common cancer in women in the United States. Due to early screening and advancements in therapeutic interventions, deaths from breast cancer have declined over time, although breast cancer remains the second leading cause of cancer death among women. Most deaths are due to metastasis, as cancer cells from the primary tumor in the breast form secondary tumors in remote sites in distant organs. Over many years, the basic biological mechanisms of breast cancer initiation and progression, as well as the subsequent metastatic cascade, have been studied using cell cultures and animal models. These models, although extremely useful for delineating cellular mechanisms, are poor predictors of physiological responses, primarily due to lack of proper microenvironments. In the last decade, microfluidics has emerged as a technology that could lead to a paradigm shift in breast cancer research. With the introduction of the organ-on-a-chip concept, microfluidic-based systems have been developed to reconstitute the dominant functions of several organs. These systems enable the construction of 3D cellular co-cultures mimicking in vivo tissue-level microenvironments, including that of breast cancer. Several reviews have been presented focusing on breast cancer formation, growth and metastasis, including invasion, intravasation, and extravasation. In this review, realizing that breast cancer can recur decades following post-treatment disease-free survival, we expand the discussion to account for microfluidic applications in the important areas of breast cancer detection, dormancy, and therapeutic development. It appears that, in the future, the role of microfluidics will only increase in the effort to eradicate breast cancer.
Collapse
Affiliation(s)
- Zachary D. Frankman
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA;
| | - Linan Jiang
- Department of Aerospace and Mechanical Engineering, University of Arizona, Tucson, AZ 85721, USA;
| | - Joyce A. Schroeder
- Department of Molecular and Cellular Biology, University of Arizona, Tucson, AZ 85721, USA;
| | - Yitshak Zohar
- Department of Aerospace and Mechanical Engineering, University of Arizona, Tucson, AZ 85721, USA;
| |
Collapse
|
10
|
Rakesh Kumar RK, Shaikh MO, Chuang CH. A review of recent advances in non-enzymatic electrochemical creatinine biosensing. Anal Chim Acta 2021; 1183:338748. [PMID: 34627521 DOI: 10.1016/j.aca.2021.338748] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 06/05/2021] [Accepted: 06/07/2021] [Indexed: 01/28/2023]
Abstract
Creatinine biosensing is a rapidly developing field owing to the clinical relevance of creatinine as a vital biomarker for several diseases associated with renal, thyroidal, and muscular dysfunctions. Over the years, we have observed numerous creatinine biosensing strategies, including the most widely studied enzymatic creatinine biosensors. Though the enzymatic approach provides excellent selectivity and reliability, it has certain drawbacks, which include high fabrication cost and poor storage stability (that is inherent to every enzyme-based biosensors). This has led to the development of non-enzymatic creatinine biosensors, of which electrochemical sensors are the most promising for point-of-care applications. However, only a limited number of studies have been conducted and there is a lack of reviews addressing the recent advances in this research area. Herein, we present for the first time, a review with a prime focus on the various strategies implemented in non-enzymatic electrochemical creatinine biosensing. We aim to offer a comprehensive context on the achievements and limitations of currently available non-enzymatic electrochemical creatinine biosensors and address the underlying factors pertaining to the interplay of modification/fabrication techniques with the sensitivity, selectivity, interferences, and long-term storage stability of the biosensor. We hope that this work shall prove to be seminal in the conception and advancement of future non-enzymatic electrochemical creatinine biosensors.
Collapse
Affiliation(s)
- R K Rakesh Kumar
- Institute of Medical Science and Technology, National Sun Yat-sen University, Taiwan
| | | | - Cheng-Hsin Chuang
- Institute of Medical Science and Technology, National Sun Yat-sen University, Taiwan.
| |
Collapse
|
11
|
Joshi A, Vishnu G K A, Sakorikar T, Kamal AM, Vaidya JS, Pandya HJ. Recent advances in biosensing approaches for point-of-care breast cancer diagnostics: challenges and future prospects. NANOSCALE ADVANCES 2021; 3:5542-5564. [PMID: 36133274 PMCID: PMC9417675 DOI: 10.1039/d1na00453k] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Accepted: 08/12/2021] [Indexed: 05/12/2023]
Abstract
Timely and accurate diagnosis of breast cancer is essential for efficient treatment and the best possible survival rates. Biosensors have emerged as a smart diagnostic platform for the detection of biomarkers specific to the onset, recurrence, and therapeutic drug monitoring of breast cancer. There have been exciting recent developments, including significant improvements in the validation, sensitivity, specificity, and integration of sample processing steps to develop point-of-care (POC) integrated micro-total analysis systems for clinical settings. The present review highlights various biosensing modalities (electrical, optical, piezoelectric, mass, and acoustic sensing). It provides deep insights into their design principles, signal amplification strategies, and comparative performance analysis. Finally, this review emphasizes the status of existing integrated micro-total analysis systems (μ-TAS) for personalized breast cancer therapeutics and associated challenges and outlines the approach required to realize their successful translation into clinical settings.
Collapse
Affiliation(s)
- Anju Joshi
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
| | - Anil Vishnu G K
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
- Centre for BioSystems Science and Engineering, Indian Institute of Science Bangalore India
| | - Tushar Sakorikar
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
| | - Arif M Kamal
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
| | - Jayant S Vaidya
- Division of Surgery and Interventional Science, University College London 4919 London UK
| | - Hardik J Pandya
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
| |
Collapse
|
12
|
Baldo TA, Proença CDA, Felix FDS, Freitas TA, Sakata SK, Angnes L, Faria RC. Disposable electrochemical microfluidic device for ultrasensitive detection of egg allergen in wine samples. Talanta 2021; 232:122447. [PMID: 34074431 DOI: 10.1016/j.talanta.2021.122447] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 04/16/2021] [Accepted: 04/17/2021] [Indexed: 12/27/2022]
Abstract
Food allergies have been increasing all over the world. Egg is an important component in the food industries and the second most common cause of food allergy, shortly after milk. In the wine industry, egg white is applied as a fining agent for tannin removal. In this study, a sandwich-based immunoassay for ultrasensitive detection of ovalbumin (OVA) in wine samples was developed. The assay involves the use of magnetic beads (MBs) decorated with a polyclonal anti-OVA antibody (Ab2) and horseradish peroxidase (HRP), used as label for the quantification in a disposable electrochemical microfluidic device (DEμD) here developed. The Ab2-MB-HRP prepared was applied to capture, separate, and pre-concentrate OVA from wine samples. In the DEμD, OVA was immune-magnetically captured (OVA-Ab2-MB-HRP), producing a sandwich structure (GO-Ab1-OVA-Ab2-MB-HRP) on the electrode's surface. This arrangement results in an ultrasensitive device, achieving the ultralow limit of detection of 0.2 fg mL-1 OVA. Five samples of wines were analyzed by using the immuno-magneto-assay which presents excellent accuracy compared with enzyme-linked immunosorbent assay (ELISA).
Collapse
Affiliation(s)
- Thaísa Aparecida Baldo
- Departamento de Química, Universidade Federal de São Carlos, 13565-905, São Carlos, São Paulo, Brazil
| | - Camila Dos Anjos Proença
- Departamento de Química, Universidade Federal de São Carlos, 13565-905, São Carlos, São Paulo, Brazil
| | - Fabiana da Silva Felix
- Departamento de Química, Universidade Federal de Lavras, CEP, 37200-900, Lavras, Minas Gerais, Brazil
| | - Tayane Aguiar Freitas
- Departamento de Química, Universidade Federal de São Carlos, 13565-905, São Carlos, São Paulo, Brazil
| | - Solange Kazumi Sakata
- Centro de Tecnologia das Radiaçõs - Instituto de Pesquisa Energéticas e Nucleares (IPEN/CNEN-SP), CEP, 05508-000, São Paulo, São Paulo, Brazil
| | - Lúcio Angnes
- Instituto de Química, Universidade de São Paulo, CEP, 05508-000, São Paulo, São Paulo, Brazil
| | - Ronaldo Censi Faria
- Departamento de Química, Universidade Federal de São Carlos, 13565-905, São Carlos, São Paulo, Brazil.
| |
Collapse
|
13
|
Zhou W, Dou M, Timilsina SS, Xu F, Li X. Recent innovations in cost-effective polymer and paper hybrid microfluidic devices. LAB ON A CHIP 2021; 21:2658-2683. [PMID: 34180494 PMCID: PMC8360634 DOI: 10.1039/d1lc00414j] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Hybrid microfluidic systems that are composed of multiple different types of substrates have been recognized as a versatile and superior platform, which can draw benefits from different substrates while avoiding their limitations. This review article introduces the recent innovations of different types of low-cost hybrid microfluidic devices, particularly focusing on cost-effective polymer- and paper-based hybrid microfluidic devices. In this article, the fabrication of these hybrid microfluidic devices is briefly described and summarized. We then highlight various hybrid microfluidic systems, including polydimethylsiloxane (PDMS)-based, thermoplastic-based, paper/polymer hybrid systems, as well as other emerging hybrid systems (such as thread-based). The special benefits of using these hybrid systems have been summarized accordingly. A broad range of biological and biomedical applications using these hybrid microfluidic devices are discussed in detail, including nucleic acid analysis, protein analysis, cellular analysis, 3D cell culture, organ-on-a-chip, and tissue engineering. The perspective trends of hybrid microfluidic systems involving the improvement of fabrication techniques and broader applications are also discussed at the end of the review.
Collapse
Affiliation(s)
- Wan Zhou
- Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA.
| | - Maowei Dou
- Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA.
| | - Sanjay S Timilsina
- Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA.
| | - Feng Xu
- Bioinspired Engineering and Biomechanics Center (BEBC), The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - XiuJun Li
- Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA. and Border Biomedical Research Center, Biomedical Engineering, University of Texas at El Paso, 500 West University Ave., El Paso, TX 79968, USA and Environmental Science and Engineering, University of Texas at El Paso, 500 West University Ave., El Paso, TX 79968, USA
| |
Collapse
|
14
|
Oliveira M, Conceição P, Kant K, Ainla A, Diéguez L. Electrochemical Sensing in 3D Cell Culture Models: New Tools for Developing Better Cancer Diagnostics and Treatments. Cancers (Basel) 2021; 13:1381. [PMID: 33803738 PMCID: PMC8003119 DOI: 10.3390/cancers13061381] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 03/08/2021] [Accepted: 03/12/2021] [Indexed: 02/07/2023] Open
Abstract
Currently, conventional pre-clinical in vitro studies are primarily based on two-dimensional (2D) cell culture models, which are usually limited in mimicking the real three-dimensional (3D) physiological conditions, cell heterogeneity, cell to cell interaction, and extracellular matrix (ECM) present in living tissues. Traditionally, animal models are used to mimic the 3D environment of tissues and organs, but they suffer from high costs, are time consuming, bring up ethical concerns, and still present many differences when compared to the human body. The applications of microfluidic-based 3D cell culture models are advantageous and useful as they include 3D multicellular model systems (MCMS). These models have demonstrated potential to simulate the in vivo 3D microenvironment with relatively low cost and high throughput. The incorporation of monitoring capabilities in the MCMS has also been explored to evaluate in real time biophysical and chemical parameters of the system, for example temperature, oxygen, pH, and metabolites. Electrochemical sensing is considered as one of the most sensitive and commercially adapted technologies for bio-sensing applications. Amalgamation of electrochemical biosensing with cell culture in microfluidic devices with improved sensitivity and performance are the future of 3D systems. Particularly in cancer, such models with integrated sensing capabilities can be crucial to assess the multiple parameters involved in tumour formation, proliferation, and invasion. In this review, we are focusing on existing 3D cell culture systems with integrated electrochemical sensing for potential applications in cancer models to advance diagnosis and treatment. We discuss their design, sensing principle, and application in the biomedical area to understand the potential relevance of miniaturized electrochemical hybrid systems for the next generation of diagnostic platforms for precision medicine.
Collapse
Affiliation(s)
- Micaela Oliveira
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
| | - Pedro Conceição
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
- Chemistry Department, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Krishna Kant
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
| | - Alar Ainla
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
| | - Lorena Diéguez
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
| |
Collapse
|
15
|
Costa-Rama E, Fernández-Abedul MT. Paper-Based Screen-Printed Electrodes: A New Generation of Low-Cost Electroanalytical Platforms. BIOSENSORS 2021; 11:51. [PMID: 33669316 PMCID: PMC7920281 DOI: 10.3390/bios11020051] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/20/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Screen-printed technology has helped considerably to the development of portable electrochemical sensors since it provides miniaturized but robust and user-friendly electrodes. Moreover, this technology allows to obtain very versatile transducers, not only regarding their design, but also their ease of modification. Therefore, in the last decades, the use of screen-printed electrodes (SPEs) has exponentially increased, with ceramic as the main substrate. However, with the growing interest in the use of cheap and widely available materials as the basis of analytical devices, paper or other low-cost flat materials have become common substrates for SPEs. Thus, in this revision, a comprehensive overview on paper-based SPEs used for analytical proposes is provided. A great variety of designs is reported, together with several examples to illustrate the main applications.
Collapse
|
16
|
Yu Z, Cai G, Liu X, Tang D. Pressure-Based Biosensor Integrated with a Flexible Pressure Sensor and an Electrochromic Device for Visual Detection. Anal Chem 2021; 93:2916-2925. [DOI: 10.1021/acs.analchem.0c04501] [Citation(s) in RCA: 114] [Impact Index Per Article: 28.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Zhenzhong Yu
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People’s Republic of China
| | - Guoneng Cai
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People’s Republic of China
| | - Xiaolong Liu
- The United Innovation of Mengchao Hepatobiliary Technology Key Laboratory of Fujian Province, Mengchao Hepatobiliary Hospital of Fujian Medical University, Fuzhou 350025, People’s Republic of China
| | - Dianping Tang
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People’s Republic of China
| |
Collapse
|
17
|
Maciel Braga LA, Mota FB. Early cancer diagnosis using lab-on-a-chip devices : A bibliometric and network analysis. COLLNET JOURNAL OF SCIENTOMETRICS AND INFORMATION MANAGEMENT 2021. [DOI: 10.1080/09737766.2021.1949949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Luiza Amara Maciel Braga
- Faculty of Economics, Fluminense Federal University, Prof. Marcos Waldemar de Freitas Reis Street, 24210-200, Brazil,
| | - Fabio Batista Mota
- Center for Strategic Studies, Oswaldo Cruz Foundation, Brasil Avenue 4036, 21040-361, Brazil
| |
Collapse
|
18
|
Feng D, Su J, Xu Y, He G, Wang C, Wang X, Pan T, Ding X, Mi X. DNA tetrahedron-mediated immune-sandwich assay for rapid and sensitive detection of PSA through a microfluidic electrochemical detection system. MICROSYSTEMS & NANOENGINEERING 2021; 7:33. [PMID: 34567747 PMCID: PMC8433179 DOI: 10.1038/s41378-021-00258-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 02/25/2021] [Accepted: 03/08/2021] [Indexed: 05/12/2023]
Abstract
Prostate-specific antigen (PSA) is the most widely used biomarker for the early diagnosis of prostate cancer. Existing methods for PSA detection are burdened with some limitations and require improvement. Herein, we developed a novel microfluidic-electrochemical (μFEC) detection system for PSA detection. First, we constructed an electrochemical biosensor based on screen-printed electrodes (SPEs) with modification of gold nanoflowers (Au NFs) and DNA tetrahedron structural probes (TSPs), which showed great detection performance. Second, we fabricated microfluidic chips by DNA TSP-Au NF-modified SPEs and a PDMS layer with designed dense meandering microchannels. Finally, the μFEC detection system was achieved based on microfluidic chips integrated with the liquid automatic conveying unit and electrochemical detection platform. The μFEC system we developed acquired great detection performance for PSA detection in PBS solution. For PSA assays in spiked serum samples of the μFEC system, we obtained a linear dynamic range of 1-100 ng/mL with a limit of detection of 0.2 ng/mL and a total reaction time <25 min. Real serum samples of prostate cancer patients presented a strong correlation between the "gold-standard" chemiluminescence assays and the μFEC system. In terms of operation procedure, cost, and reaction time, our method was superior to the current methods for PSA detection and shows great potential for practical clinical application in the future.
Collapse
Affiliation(s)
- Dezhi Feng
- Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 200050 Shanghai, China
- Shanghai Advanced Research Institute, Chinese Academy of Sciences, 201210 Shanghai, China
- University of Chinese Academy of Sciences, 100049 Beijing, China
| | - Jing Su
- State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, School of Biomedical Engineering, Shanghai Jiao Tong University, 200030 Shanghai, China
| | - Yi Xu
- Shanghai Advanced Research Institute, Chinese Academy of Sciences, 201210 Shanghai, China
| | - Guifang He
- Shanghai Advanced Research Institute, Chinese Academy of Sciences, 201210 Shanghai, China
- School of Life Sciences, Shanghai University, 200444 Shanghai, China
| | - Chenguang Wang
- Shanghai Advanced Research Institute, Chinese Academy of Sciences, 201210 Shanghai, China
- University of Chinese Academy of Sciences, 100049 Beijing, China
| | - Xiao Wang
- Shanghai Advanced Research Institute, Chinese Academy of Sciences, 201210 Shanghai, China
- School of Life Sciences, Shanghai University, 200444 Shanghai, China
| | - Tingrui Pan
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Science, 518055 Shenzhen, China
| | - Xianting Ding
- State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, School of Biomedical Engineering, Shanghai Jiao Tong University, 200030 Shanghai, China
| | - Xianqiang Mi
- Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 200050 Shanghai, China
- Shanghai Advanced Research Institute, Chinese Academy of Sciences, 201210 Shanghai, China
- University of Chinese Academy of Sciences, 100049 Beijing, China
- CAS Center for Excellence in Superconducting Electronics, (CENSE), 200050 Shanghai, China
- Key Laboratory of Systems Health Science of Zhejiang Province, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 310024 Hangzhou, China
| |
Collapse
|
19
|
Suhito IR, Koo KM, Kim TH. Recent Advances in Electrochemical Sensors for the Detection of Biomolecules and Whole Cells. Biomedicines 2020; 9:15. [PMID: 33375330 PMCID: PMC7824644 DOI: 10.3390/biomedicines9010015] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 12/22/2020] [Accepted: 12/23/2020] [Indexed: 02/06/2023] Open
Abstract
Electrochemical sensors are considered an auspicious tool to detect biomolecules (e.g., DNA, proteins, and lipids), which are valuable sources for the early diagnosis of diseases and disorders. Advances in electrochemical sensing platforms have enabled the development of a new type of biosensor, enabling label-free, non-destructive detection of viability, function, and the genetic signature of whole cells. Numerous studies have attempted to enhance both the sensitivity and selectivity of electrochemical sensors, which are the most critical parameters for assessing sensor performance. Various nanomaterials, including metal nanoparticles, carbon nanotubes, graphene and its derivatives, and metal oxide nanoparticles, have been used to improve the electrical conductivity and electrocatalytic properties of working electrodes, increasing sensor sensitivity. Further modifications have been implemented to advance sensor platform selectivity and biocompatibility using biomaterials such as antibodies, aptamers, extracellular matrix (ECM) proteins, and peptide composites. This paper summarizes recent electrochemical sensors designed to detect target biomolecules and animal cells (cancer cells and stem cells). We hope that this review will inspire researchers to increase their efforts to accelerate biosensor progress-enabling a prosperous future in regenerative medicine and the biomedical industry.
Collapse
Affiliation(s)
- Intan Rosalina Suhito
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Korea; (I.R.S.); (K.-M.K.)
| | - Kyeong-Mo Koo
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Korea; (I.R.S.); (K.-M.K.)
| | - Tae-Hyung Kim
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Korea; (I.R.S.); (K.-M.K.)
- Integrative Research Center for Two-Dimensional Functional Materials, Institute of Interdisciplinary Convergence Research, Chung Ang University, Seoul 06974, Korea
| |
Collapse
|
20
|
Sardini E, Serpelloni M, Tonello S. Printed Electrochemical Biosensors: Opportunities and Metrological Challenges. BIOSENSORS 2020; 10:E166. [PMID: 33158129 PMCID: PMC7694196 DOI: 10.3390/bios10110166] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 10/30/2020] [Accepted: 11/02/2020] [Indexed: 12/14/2022]
Abstract
Printed electrochemical biosensors have recently gained increasing relevance in fields ranging from basic research to home-based point-of-care. Thus, they represent a unique opportunity to enable low-cost, fast, non-invasive and/or continuous monitoring of cells and biomolecules, exploiting their electrical properties. Printing technologies represent powerful tools to combine simpler and more customizable fabrication of biosensors with high resolution, miniaturization and integration with more complex microfluidic and electronics systems. The metrological aspects of those biosensors, such as sensitivity, repeatability and stability, represent very challenging aspects that are required for the assessment of the sensor itself. This review provides an overview of the opportunities of printed electrochemical biosensors in terms of transducing principles, metrological characteristics and the enlargement of the application field. A critical discussion on metrological challenges is then provided, deepening our understanding of the most promising trends in order to overcome them: printed nanostructures to improve the limit of detection, sensitivity and repeatability; printing strategies to improve organic biosensor integration in biological environments; emerging printing methods for non-conventional substrates; microfluidic dispensing to improve repeatability. Finally, an up-to-date analysis of the most recent examples of printed electrochemical biosensors for the main classes of target analytes (live cells, nucleic acids, proteins, metabolites and electrolytes) is reported.
Collapse
Affiliation(s)
- Emilio Sardini
- Department of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy; (E.S.); (M.S.)
| | - Mauro Serpelloni
- Department of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy; (E.S.); (M.S.)
| | - Sarah Tonello
- Department of Information Engineering, University of Padova, Via Gradenigo 6, 35131 Padova, Italy
| |
Collapse
|
21
|
Hernández-Rodríguez JF, Della Pelle F, Rojas D, Compagnone D, Escarpa A. Xurography-Enabled Thermally Transferred Carbon Nanomaterial-Based Electrochemical Sensors on Polyethylene Terephthalate-Ethylene Vinyl Acetate Films. Anal Chem 2020; 92:13565-13572. [PMID: 32869640 DOI: 10.1021/acs.analchem.0c03240] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
A novel benchtop approach to fabricate xurography-enabled thermally transferred (XTT) carbon nanomaterial-based electrochemical sensors is proposed. Filtered nanomaterial (NM) films were transferred from Teflon filters to polyethylene terephthalate-ethylene vinyl acetate (PET-EVA) substrates by a temperature-driven approach. Customized PET-EVA components were xurographically patterned by a cutting plotter. The smart design of PET-EVA films enabled us to selectively transfer the nanomaterial to the exposed EVA side of the substrate. Hence, the substrate played an active role in selectively controlling where nanomaterial transfer occurred allowing us to design different working electrode geometries. Counter and reference electrodes were integrated by a stencil-printing approach, and the whole device was assembled by thermal lamination. To prove the versatility of the technology, XTT materials were exclusively made of carbon black (XTT-CB), multiwalled carbon nanotubes (XTT-MWCNTs), and single-walled carbon nanotubes (XTT-SWCNTs). Their electrochemical behavior was carefully studied and was found to be highly dependent on the amount and type of NM employed. XTT-SWCNTs were demonstrated to be the best-performing sensors, and they were employed for the determination of l-tyrosine (l-Tyr) in human plasma from tyrosinemia-diagnosed patients. High analytical performance toward l-Tyr (linear range of 0.5-100 μM, LOD = 0.1 μM), interelectrode precision (RSD ip,a = 3%, n = 10; RSD calibration slope = 4%, n = 3), and accurate l-Tyr quantification in plasma samples with low relative errors (≤7%) compared to the clinical declared values were obtained. The proposed benchtop approach is cost-effective and straightforward, does not require sophisticated facilities, and can be potentially employed to develop pure or hybrid nanomaterial-based electrodes.
Collapse
Affiliation(s)
- Juan F Hernández-Rodríguez
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain
| | - Flavio Della Pelle
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100 Teramo, Italy
| | - Daniel Rojas
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100 Teramo, Italy
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100 Teramo, Italy
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Chemical Research Institute Andres M. del Rio, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain
| |
Collapse
|
22
|
Printed Electrodes in Microfluidic Arrays for Cancer Biomarker Protein Detection. BIOSENSORS-BASEL 2020; 10:bios10090115. [PMID: 32906644 PMCID: PMC7559629 DOI: 10.3390/bios10090115] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/27/2020] [Accepted: 09/01/2020] [Indexed: 12/27/2022]
Abstract
Medical diagnostics is trending towards a more personalized future approach in which multiple tests can be digitized into patient records. In cancer diagnostics, patients can be tested for individual protein and genomic biomarkers that detect cancers at very early stages and also be used to monitor cancer progression or remission during therapy. These data can then be incorporated into patient records that could be easily accessed on a cell phone by a health care professional or the patients themselves on demand. Data on protein biomarkers have a large potential to be measured in point-of-care devices, particularly diagnostic panels that could provide a continually updated, personalized record of a disease like cancer. Electrochemical immunoassays have been popular among protein detection methods due to their inherent high sensitivity and ease of coupling with screen-printed and inkjet-printed electrodes. Integrated chips featuring these kinds of electrodes can be built at low cost and designed for ease of automation. Enzyme-linked immunosorbent assay (ELISA) features are adopted in most of these ultrasensitive detection systems, with microfluidics allowing easy manipulation and good fluid dynamics to deliver reagents and detect the desired proteins. Several of these ultrasensitive systems have detected biomarker panels ranging from four to eight proteins, which in many cases when a specific cancer is suspected may be sufficient. However, a grand challenge lies in engineering microfluidic-printed electrode devices for the simultaneous detection of larger protein panels (e.g., 50-100) that could be used to test for many types of cancers, as well as other diseases for truly personalized care.
Collapse
|
23
|
Tanis SN, Ilhan H, Guven B, Tayyarcan EK, Ciftci H, Saglam N, Hakki Boyaci I, Tamer U. A disposable gold-cellulose nanofibril platform for SERS mapping. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3164-3172. [PMID: 32930178 DOI: 10.1039/d0ay00662a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In this study, we present a disposable and inexpensive paper-like gold nanoparticle-embedded cellulose nanofibril substrate for the rapid enumeration of Escherichia coli (E. coli) using surface-enhanced Raman scattering (SERS) mapping. A disposable SERS substrate was simply constructed by mixing CNF and gold chloride solution at 120 °C in a water bath. The application of the resulting substrate was carried out by enrichment and SERS detection of E. coli. To this end, the spherical gold nanoparticle-embedded cellulose nanofibril substrate was used as a scavenger for E. coli. After the target bacteria E. coli were separated from the matrix via oriented antibodies, the sandwich assay procedure was carried out using 5,5-dithiobis-(2-nitrobenzoic acid) (DTNB)-coated Au nanorod particles that acted as SERS mapping probes. The distribution density of DTNB was demonstrated visually using SERS mapping, and the assay was completed in one hour. The correlation between the E. coli and SERS mapping signals was found to be linear within the range of 15 cfu mL-1 to 1.5 × 105 cfu mL-1. The limit of detection for the SERS mapping assay was determined to be 2 cfu mL-1. The selectivity of the developed method was examined with Micrococcus luteus (M. luteus), Bacillus subtilis (B. subtilis), and Enterobacter aerogenes (E. aerogenes), which did not produce any significant response. Furthermore, the developed method was evaluated for detecting E. coli in artificially contaminated samples, and the results were compared with those of the plate-counting method.
Collapse
Affiliation(s)
- Saliha Nur Tanis
- Department of Nanotechnology, Faculty of Science, Hacettepe University, Beytepe, 06800, Ankara, Turkey
| | - Hasan Ilhan
- Faculty of Art and Science, Ordu University, Altınordu, 52200, Ordu, Turkey
| | - Burcu Guven
- Department of Food Engineering, Faculty of Engineering, Hacettepe University, Beytepe, 06800, Ankara, Turkey
| | - Emine Kubra Tayyarcan
- Department of Food Engineering, Faculty of Engineering, Hacettepe University, Beytepe, 06800, Ankara, Turkey
| | - Hakan Ciftci
- Department of Chemistry and Chemical Processing Technologies, Kirikkale Vocational High School, Kirikkale University, Yahsihan, 71450, Kirikkale, Turkey
| | - Necdet Saglam
- Department of Nanotechnology, Faculty of Science, Hacettepe University, Beytepe, 06800, Ankara, Turkey
| | - Ismail Hakki Boyaci
- Department of Food Engineering, Faculty of Engineering, Hacettepe University, Beytepe, 06800, Ankara, Turkey
| | - Ugur Tamer
- Department of Analytical Chemistry, Faculty of Pharmacy, Gazi University, Etiler, 06330, Ankara, Turkey.
| |
Collapse
|
24
|
de Oliveira TR, Erbereli CR, Manzine PR, Magalhães TNC, Balthazar MLF, Cominetti MR, Faria RC. Early Diagnosis of Alzheimer's Disease in Blood Using a Disposable Electrochemical Microfluidic Platform. ACS Sens 2020; 5:1010-1019. [PMID: 32207606 DOI: 10.1021/acssensors.9b02463] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Alzheimer's disease (AD) is a neurodegenerative condition that affects a large number of elderly people worldwide and has a high social and economic impact. The diagnosis of AD in early stage can significantly improve the evolution and prognosis of the disease. We report the use of A Disintegrin And Metalloprotease 10 (ADAM10) as a blood biomarker for the early diagnosis of AD. A simple, low-cost, sensitive, and disposable microfluidic platform (DμP) was developed for ADAM10 detection in plasma and cerebrospinal fluid based on electrochemical immunosensors. The assay was designed to accurately detect ADAM10 in serum, with a limit of detection of 0.35 fg/mL. ADAM10 was detected in subjects divided into cognitively healthy subjects, subjects with mild cognitive impairment, and AD patients in different disease stages. An increase in protein levels was found throughout the disease, and good DμP accuracy in differentiating individuals was observed. The DμP provided significantly better sensitivity than the well-established enzyme-linked immunosorbent assay test. ADAM10 and its detection using the DμP were proven to be an alternative tool for the early diagnosis and monitoring of AD, bringing new exciting possibilities to improve the quality of life of AD patients.
Collapse
Affiliation(s)
- Tássia R. de Oliveira
- Department of Chemistry, Federal University of São Carlos, São Carlos, São Paulo 13565-905, Brazil
| | - Camila R. Erbereli
- Department of Chemistry, Federal University of São Carlos, São Carlos, São Paulo 13565-905, Brazil
| | - Patricia R. Manzine
- Department of Gerontology, Federal University of São Carlos, São Carlos, São Paulo 13565-905, Brazil
| | | | | | - Márcia R. Cominetti
- Department of Gerontology, Federal University of São Carlos, São Carlos, São Paulo 13565-905, Brazil
| | - Ronaldo C. Faria
- Department of Chemistry, Federal University of São Carlos, São Carlos, São Paulo 13565-905, Brazil
| |
Collapse
|
25
|
Tang C, He Z, Liu H, Xu Y, Huang H, Yang G, Xiao Z, Li S, Liu H, Deng Y, Chen Z, Chen H, He N. Application of magnetic nanoparticles in nucleic acid detection. J Nanobiotechnology 2020; 18:62. [PMID: 32316985 PMCID: PMC7171821 DOI: 10.1186/s12951-020-00613-6] [Citation(s) in RCA: 96] [Impact Index Per Article: 19.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 03/25/2020] [Indexed: 12/16/2022] Open
Abstract
Nucleic acid is the main material for storing, copying, and transmitting genetic information. Gene sequencing is of great significance in DNA damage research, gene therapy, mutation analysis, bacterial infection, drug development, and clinical diagnosis. Gene detection has a wide range of applications, such as environmental, biomedical, pharmaceutical, agriculture and forensic medicine to name a few. Compared with Sanger sequencing, high-throughput sequencing technology has the advantages of larger output, high resolution, and low cost which greatly promotes the application of sequencing technology in life science research. Magnetic nanoparticles, as an important part of nanomaterials, have been widely used in various applications because of their good dispersion, high surface area, low cost, easy separation in buffer systems and signal detection. Based on the above, the application of magnetic nanoparticles in nucleic acid detection was reviewed.
Collapse
Affiliation(s)
- Congli Tang
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Ziyu He
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Hongmei Liu
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Yuyue Xu
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Hao Huang
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Gaojian Yang
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Ziqi Xiao
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Song Li
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Hongna Liu
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Yan Deng
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
- State Key Laboratory of Bioelectronics, Southeast University, Nanjing, 210096 China
| | - Zhu Chen
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Hui Chen
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, 412007 China
| | - Nongyue He
- State Key Laboratory of Bioelectronics, Southeast University, Nanjing, 210096 China
| |
Collapse
|
26
|
Fava EL, Martimiano do Prado T, Almeida Silva T, Cruz de Moraes F, Censi Faria R, Fatibello‐Filho O. New Disposable Electrochemical Paper‐based Microfluidic Device with Multiplexed Electrodes for Biomarkers Determination in Urine Sample. ELECTROANAL 2020. [DOI: 10.1002/elan.201900641] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Elson Luiz Fava
- Department of Chemistry Federal University of São Carlos São Carlos, P.O. Box 676 13560-970, SP Brazil
| | | | - Tiago Almeida Silva
- Department of Chemistry Federal University of São Carlos São Carlos, P.O. Box 676 13560-970, SP Brazil
- Department of Metallurgy and Chemistry Federal Center for Technological Education of Minas Gerais Timóteo 35180-008, MG Brazil
| | - Fernando Cruz de Moraes
- Department of Chemistry Federal University of São Carlos São Carlos, P.O. Box 676 13560-970, SP Brazil
| | - Ronaldo Censi Faria
- Department of Chemistry Federal University of São Carlos São Carlos, P.O. Box 676 13560-970, SP Brazil
| | - Orlando Fatibello‐Filho
- Department of Chemistry Federal University of São Carlos São Carlos, P.O. Box 676 13560-970, SP Brazil
| |
Collapse
|
27
|
Liu R, Ye X, Cui T. Recent Progress of Biomarker Detection Sensors. RESEARCH (WASHINGTON, D.C.) 2020; 2020:7949037. [PMID: 33123683 PMCID: PMC7585038 DOI: 10.34133/2020/7949037] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 09/13/2020] [Indexed: 12/11/2022]
Abstract
Early cancer diagnosis and treatment are crucial research fields of human health. One method that has proven efficient is biomarker detection which can provide real-time and accurate biological information for early diagnosis. This review presents several biomarker sensors based on electrochemistry, surface plasmon resonance (SPR), nanowires, other nanostructures, and, most recently, metamaterials which have also shown their mechanisms and prospects in application in recent years. Compared with previous reviews, electrochemistry-based biomarker sensors have been classified into three strategies according to their optimizing methods in this review. This makes it more convenient for researchers to find a specific fabrication method to improve the performance of their sensors. Besides that, as microfabrication technologies have improved and novel materials are explored, some novel biomarker sensors-such as nanowire-based and metamaterial-based biomarker sensors-have also been investigated and summarized in this review, which can exhibit ultrahigh resolution, sensitivity, and limit of detection (LoD) in a more complex detection environment. The purpose of this review is to understand the present by reviewing the past. Researchers can break through bottlenecks of existing biomarker sensors by reviewing previous works and finally meet the various complex detection needs for the early diagnosis of human cancer.
Collapse
Affiliation(s)
- Ruitao Liu
- State Key Lab Precise Measurement Technology & Instrument, Department of Precision Instruments, Tsinghua University, Beijing, China
| | - Xiongying Ye
- State Key Lab Precise Measurement Technology & Instrument, Department of Precision Instruments, Tsinghua University, Beijing, China
| | - Tianhong Cui
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
28
|
Proença CA, Freitas TA, Baldo TA, Materón EM, Shimizu FM, Ferreira GR, Soares FLF, Faria RC, Oliveira ON. Use of data processing for rapid detection of the prostate-specific antigen biomarker using immunomagnetic sandwich-type sensors. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2019; 10:2171-2181. [PMID: 31807403 PMCID: PMC6880837 DOI: 10.3762/bjnano.10.210] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Accepted: 10/07/2019] [Indexed: 05/03/2023]
Abstract
Diagnosis of cancer using electroanalytical methods can be achieved at low cost and in rapid assays, but this may require the combination with data treatment for determining biomarkers in real samples. In this paper, we report an immunomagnetic nanoparticle-based microfluidic sensor (INμ-SPCE) for the amperometric detection of the prostate-specific antigen (PSA) biomarker, the data of which were treated with information visualization methods. The INμ-SPCE consists of eight working electrodes, reference and counter electrodes. On the working electrodes, magnetic nanoparticles with secondary antibodies with the enzyme horseradish peroxidase were immobilized for the indirect detection of PSA in a sandwich-type procedure. Under optimal conditions, the immunosensor could operate within a wide range from 12.5 to 1111 fg·L-1, with a low detection limit of 0.062 fg·L-1. Multidimensional projections combined with feature selection allowed for the distinction of cell lysates with different levels of PSA, in agreement with results from the traditional enzyme-linked immunosorbent assay. The approaches for immunoassays and data processing are generic, and therefore the strategies described here may provide a simple platform for clinical diagnosis of cancers and other types of diseases.
Collapse
Affiliation(s)
- Camila A Proença
- Chemistry Department, Federal University of São Carlos, CP 676, São Carlos 13565-905, São Paulo, Brazil
| | - Tayane A Freitas
- Chemistry Department, Federal University of São Carlos, CP 676, São Carlos 13565-905, São Paulo, Brazil
| | - Thaísa A Baldo
- Chemistry Department, Federal University of São Carlos, CP 676, São Carlos 13565-905, São Paulo, Brazil
| | - Elsa M Materón
- Chemistry Department, Federal University of São Carlos, CP 676, São Carlos 13565-905, São Paulo, Brazil
- São Carlos Institute of Physics, University of São Paulo, CP 369, São Carlos 13560-970, São Paulo, Brazil
| | - Flávio M Shimizu
- São Carlos Institute of Physics, University of São Paulo, CP 369, São Carlos 13560-970, São Paulo, Brazil
- Brazilian Nanotechnology National Laboratory (LNNano), Brazilian Center for Research in Energy and Materials (CNPEM), Campinas 13083-970, São Paulo, Brazil
| | - Gabriella R Ferreira
- Carlos Institute of Chemistry, University of São Paulo, São Carlos 13560-970, São Paulo, Brazil
| | - Frederico L F Soares
- Chemistry Department, Federal University of São Carlos, CP 676, São Carlos 13565-905, São Paulo, Brazil
- Chemistry Department, Federal University of Paraná, Curitiba, 81531-980, Paraná, Brazil
| | - Ronaldo C Faria
- Chemistry Department, Federal University of São Carlos, CP 676, São Carlos 13565-905, São Paulo, Brazil
| | - Osvaldo N Oliveira
- São Carlos Institute of Physics, University of São Paulo, CP 369, São Carlos 13560-970, São Paulo, Brazil
| |
Collapse
|
29
|
Novel enzyme-free immunomagnetic microfluidic device based on Co0.25Zn0.75Fe2O4 for cancer biomarker detection. Anal Chim Acta 2019; 1071:59-69. [DOI: 10.1016/j.aca.2019.04.047] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 03/30/2019] [Accepted: 04/19/2019] [Indexed: 12/17/2022]
|
30
|
Venturini Uliana C, Yamanaka H. Immunosensor for Detection of the Textile Dye Disperse Orange 1 Based on Non‐conventional Competitive Assay. ELECTROANAL 2019. [DOI: 10.1002/elan.201900059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Carolina Venturini Uliana
- São Paulo State University-UnespInstitute of Chemistry P.O. Box 355 14800-900 Araraquara-SP Brazil
- São Paulo State University-UnespNational Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry P.O. Box 355 14800-900 Araraquara-SP Brazil
| | - Hideko Yamanaka
- São Paulo State University-UnespInstitute of Chemistry P.O. Box 355 14800-900 Araraquara-SP Brazil
- São Paulo State University-UnespNational Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry P.O. Box 355 14800-900 Araraquara-SP Brazil
| |
Collapse
|
31
|
Freitas TA, Proença CA, Baldo TA, Materón EM, Wong A, Magnani RF, Faria RC. Ultrasensitive immunoassay for detection of Citrus tristeza virus in citrus sample using disposable microfluidic electrochemical device. Talanta 2019; 205:120110. [PMID: 31450419 DOI: 10.1016/j.talanta.2019.07.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 06/27/2019] [Accepted: 07/01/2019] [Indexed: 01/21/2023]
Abstract
Tristeza is a disease that affects citrus crops in general, caused by the Citrus tristeza virus (CTV). It is considered an economically important virus diseases in citrus, which is present in the main citrus producing regions all around the world. Early detection of CTV is crucial to avoid any epidemics and substantial economic losses for the citrus growers. Consequently, the development of rapid, accurate, and sensitive methods capable of detecting the virus in the early stages of the disease is highly desired. Based on that, a low-cost and rapid magneto-immunoassay methodology to detect the capsid protein from CTV (CP-CTV) was proposed. For this, magnetic beads were decorated with antibodies anti-CP-CTV and horseradish peroxidase enzyme (HRP) and applied for the capture and separation of CP-CTV from the sample solutions. The magnetically captured biomarker was detected using a simple disposable microfluidic electrochemical device (DμFED) constructed by rapid prototyping technique and composed by an array of immunosensors. In DμFED, the electrodes were modified with monoclonal antibody anti-CP-CTV and the detection was carried out using amperometry, based on the hydroquinone/H2O2 catalytic redox reaction due to the presence of HRP label in an immune-sandwich structure. The proposed immunoassay presented excellent linearity with a wide linear range of concentration of 1.95-10.0 × 103 fg mL-1 and ultralow detection limit of 0.3 fg mL-1. The disposable device was successfully applied for the detection of Citrus tristeza virus in healthy and infected plant samples, where it showed good agreements with the comparative method of enzyme-linked immunosorbent assay (ELISA). The developed immunoassay methodology showed a sensitive and selective way in the detection of CTV. Hence, it can be considered as a promising analytical alternative for rapid and low-cost diagnosis of Tristeza disease in citrus.
Collapse
Affiliation(s)
- Tayane A Freitas
- Department of Chemistry, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil
| | - Camila A Proença
- Department of Chemistry, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil
| | - Thaísa A Baldo
- Department of Chemistry, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil
| | - Elsa M Materón
- Department of Chemistry, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil
| | - Ademar Wong
- Department of Chemistry, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil
| | - Rodrigo F Magnani
- Departamento de Pesquisa & Desenvolvimento, Fundecitrus, Araraquara, SP, 14807-040, Brazil; Department of Chemistry, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil
| | - Ronaldo C Faria
- Department of Chemistry, Federal University of São Carlos, São Carlos, SP, 13565-905, Brazil.
| |
Collapse
|
32
|
Fava EL, Silva TA, Prado TMD, Moraes FCD, Faria RC, Fatibello-Filho O. Electrochemical paper-based microfluidic device for high throughput multiplexed analysis. Talanta 2019; 203:280-286. [PMID: 31202339 DOI: 10.1016/j.talanta.2019.05.081] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 05/17/2019] [Accepted: 05/18/2019] [Indexed: 01/04/2023]
Abstract
A disposable microfluidic electrochemical paper-based device for multiplexed analysis based on sixteen independent microfluidic channels with electrochemical detection is proposed. A major advantage of this work was the non-necessary use of a wax printer for devices manufacturing which has a high cost of operation. In addition, a commercial multiplexing module was used that has the multiplexing capability of 8-16 channels and, for the first time using this module, the strategy of multiplexing both the working and reference electrodes were used. These sixteen channels with the respective sensors can be operated employing one or multiple electrochemical techniques with good repeatability and reproducibility for high throughput analysis. As a proof of concept, the electrochemical performance of device was tested with ferrocenecarboxylic acid solution employing cyclic voltammetry, square-wave voltammetry, differential-pulse voltammetry and chronoamperometry. This innovative sensing platform presented capacity of production in large scale and application for clinical tests with safety and short time of assays. A biosensor was constructed using glucose oxidase on the platform for the glucose determination in urine as a non-invasive strategy. The analytical curve was linear in the glucose concentration range from 1.0 × 10-4 mol L-1 to 4 × 10-2 mol L-1, with a limit of detection of 3 × 10-5 mol L-1.
Collapse
Affiliation(s)
- Elson Luiz Fava
- Department of Chemistry, Federal University of São Carlos, São Carlos, P.O. Box 676, 13560-970, SP, Brazil
| | - Tiago Almeida Silva
- Department of Chemistry, Federal University of São Carlos, São Carlos, P.O. Box 676, 13560-970, SP, Brazil; Department of Metallurgy and Chemistry, Federal Center for Technological Education of Minas Gerais, Timóteo, 35180-008, MG, Brazil
| | - Thiago Martimiano do Prado
- Department of Chemistry, Federal University of São Carlos, São Carlos, P.O. Box 676, 13560-970, SP, Brazil
| | - Fernando Cruz de Moraes
- Department of Chemistry, Federal University of São Carlos, São Carlos, P.O. Box 676, 13560-970, SP, Brazil
| | - Ronaldo Censi Faria
- Department of Chemistry, Federal University of São Carlos, São Carlos, P.O. Box 676, 13560-970, SP, Brazil.
| | - Orlando Fatibello-Filho
- Department of Chemistry, Federal University of São Carlos, São Carlos, P.O. Box 676, 13560-970, SP, Brazil.
| |
Collapse
|
33
|
Pastucha M, Farka Z, Lacina K, Mikušová Z, Skládal P. Magnetic nanoparticles for smart electrochemical immunoassays: a review on recent developments. Mikrochim Acta 2019; 186:312. [PMID: 31037494 DOI: 10.1007/s00604-019-3410-0] [Citation(s) in RCA: 64] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Accepted: 04/03/2019] [Indexed: 02/07/2023]
Abstract
This review (with 129 refs) summarizes the progress in electrochemical immunoassays combined with magnetic particles that was made in the past 5 years. The specifity of antibodies linked to electrochemical transduction (by amperometry, voltammetry, impedimetry or electrochemiluminescence) gains further attractive features by introducing magnetic nanoparticles (MNPs). This enables fairly easy preconcentration of analytes, minimizes matrix effects, and introduces an appropriate label. Following an introduction into the fundamentals of electrochemical immunoassays and on nanomaterials for respective uses, a large chapter addresses method for magnetic capture and preconcentration of analytes. A next chapter discusses commonly used labels such as dots, enzymes, metal and metal oxide nanoparticles and combined clusters. The large field of hybrid nanomaterials for use in such immunoassays is discussed next, with a focus on MNPs composites with various kinds of graphene variants, polydopamine, noble metal nanoparticles or nanotubes. Typical applications address clinical markers (mainly blood and urine parameters), diagnosis of cancer (markers and cells), detection of pathogens (with subsections on viruses and bacteria), and environmental and food contaminants as toxic agents and pesticides. A concluding section summarizes the present status, current challenges, and highlights future trends. Graphical abstract Magnetic nanoparticles (MNP) with antibodies (Ab) capture and preconcentrate analyte from sample (a) and afterwards become magnetically (b) or immunospecifically (c) bound at an electrode. Signal either increases due to the presence of alabel (b) or decreases as the redox probe is blocked (c).
Collapse
Affiliation(s)
- Matěj Pastucha
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
- Central European Institute of Technology, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
| | - Zdeněk Farka
- Central European Institute of Technology, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
| | - Karel Lacina
- Central European Institute of Technology, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
| | - Zuzana Mikušová
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
- Central European Institute of Technology, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
| | - Petr Skládal
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic.
- Central European Institute of Technology, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic.
| |
Collapse
|
34
|
Yáñez-Sedeño P, Campuzano S, Pingarrón JM. Pushing the limits of electrochemistry toward challenging applications in clinical diagnosis, prognosis, and therapeutic action. Chem Commun (Camb) 2019; 55:2563-2592. [PMID: 30688320 DOI: 10.1039/c8cc08815b] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Constant progress in the identification of biomarkers at different molecular levels in samples of different natures, and the need to conduct routine analyses, even in limited-resource settings involving simple and short protocols, are examples of the growing current clinical demands not satisfied by conventional available techniques. In this context, the unique features offered by electrochemical biosensors, including affordability, real-time and reagentless monitoring, simple handling and portability, and versatility, make them especially interesting for adaptation to the increasingly challenging requirements of current clinical and point-of-care (POC) diagnostics. This has allowed the continuous development of strategies with improved performance in the clinical field that were unthinkable just a few years ago. After a brief introduction to the types and characteristics of clinically relevant biomarkers/samples, requirements for their analysis, and currently available methodologies, this review article provides a critical discussion of the most important developments and relevant applications involving electrochemical biosensors reported in the last five years in response to the demands of current diagnostic, prognostic, and therapeutic actions related to high prevalence and high mortality diseases and disorders. Special attention is paid to the rational design of surface chemistry and the use/modification of state-of-the-art nanomaterials to construct electrochemical bioscaffolds with antifouling properties that can be applied to the single or multiplex determination of biomarkers of accepted or emerging clinical relevance in particularly complex clinical samples, such as undiluted liquid biopsies, whole cells, and paraffin-embedded tissues, which have scarcely been explored using conventional techniques or electrochemical biosensing. Key points guiding future development, challenges to be addressed to further push the limits of electrochemical biosensors towards new challenging applications, and their introduction to the market are also discussed.
Collapse
Affiliation(s)
- P Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
| | | | | |
Collapse
|
35
|
Qin D, Jiang X, Mo G, Feng J, Yu C, Deng B. A Novel Carbon Quantum Dots Signal Amplification Strategy Coupled with Sandwich Electrochemiluminescence Immunosensor for the Detection of CA15-3 in Human Serum. ACS Sens 2019; 4:504-512. [PMID: 30693767 DOI: 10.1021/acssensors.8b01607] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
A sensitive sandwich electrochemiluminescence immunosensor was established by employing graphene oxide-PEI-carbon quantum dots (CQDs)-Au nanohybrid as probe to measure carbohydrate antigen 15-3 (CA15-3), a breast cancer biomarker. In this work, nanocomposites of Ag nanoparticles and polydopamine (AgNPs-PDA) were synthesized by redox reaction between dopamine and Ag+. The nanocomposite with high surface area can provide an efficient substrate for immobilizing initial antibody (Ab1). Carbon quantum dots (CQDs) are fixed on polyethylenimine-functionalized graphene oxide (PEI-GO) by amide bonds. Au nanoparticles are modified on CQDs-decorated PEI-GO substrates. The secondary antibody (Ab2) was immobilized by AuNPs/CQDs-PEI-GO composite. CQDs can be assembled onto the surface of an electrode by incorporation of CA15-3 with Ab1 and Ab2. Under the synergistic action of AgNPs, polydopamine, AuNPs, and PEI-GO, the ECL signal of CQDs is greatly amplified as an excellent conductive material to facilitate electron transfer rate and further increase electrochemical detection capability. Under optimal conditions, the fabricated immunosensor showed a linear concentration range from 0.005 to 500 U mL-1, with a detection limit of 0.0017 U mL-1 (signal-to-noise ratio of 3) for CA15-3. The designed ECL immunosensor displayed receivable accuracy, excellent stability, and high specificity. The results of the detection of human serum samples are satisfactory, revealing that the method offers a potential application for the clinical diagnosis of tumor markers.
Collapse
Affiliation(s)
- Dongmiao Qin
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004 China
| | - Xiaohua Jiang
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004 China
| | - Guichun Mo
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004 China
| | - Jinsu Feng
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004 China
| | - Chunhe Yu
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004 China
| | - Biyang Deng
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004 China
| |
Collapse
|
36
|
Label-free evaluation of small-molecule-protein interaction using magnetic capture and electrochemical detection. Anal Bioanal Chem 2019; 411:2111-2119. [PMID: 30739194 DOI: 10.1007/s00216-019-01636-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Accepted: 01/22/2019] [Indexed: 12/17/2022]
Abstract
The evaluation of interaction between small molecules and protein is an important step in the discovery of new drugs and to study complex biological systems. In this work, an alternative method was presented to evaluate small-molecule-protein interaction by using ligand capture by protein-coated magnetic particles (MPs) and disposable electrochemical cells. The interaction study was conducted using [10]-gingerol from ginger rhizome and a transmembrane protein αVβ3 integrin. Initially, the electrochemical behavior of the natural compound [10]-gingerol was evaluated with the disposable carbon-based electrodes and presented an irreversible oxidation process controlled by diffusion. The analytical curve for [10]-gingerol was obtained in the range of 1.0 to 20.0 μmol L-1, with limit of detection of 0.26 μmol L-1. Then MPs coated with αVβ3 integrin were incubated with standard solutions and extracts of ginger rhizome for [10]-gingerol capture and separation. The bioconjugate obtained was dropped to the disposable electrochemical cells, keeping a permanent magnet behind the working electrode, and the binding process was evaluated by the electrochemical detection of [10]-gingerol. The assay method proposed was also employed to calculate the [10]-gingerol-αVβ3 integrin association constant, which was calculated as 4.3 × 107 M-1. The method proposed proved to be a good label-free alternative to ligand-protein interaction studies. Graphical abstract ᅟ.
Collapse
|
37
|
Felix FS, Baccaro ALB, Angnes L. Disposable Voltammetric Immunosensors Integrated with Microfluidic Platforms for Biomedical, Agricultural and Food Analyses: A Review. SENSORS 2018; 18:s18124124. [PMID: 30477240 PMCID: PMC6308430 DOI: 10.3390/s18124124] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Revised: 11/15/2018] [Accepted: 11/21/2018] [Indexed: 12/19/2022]
Abstract
Disposable immunosensors are analytical devices used for the quantification of a broad variety of analytes in different areas such as clinical, environmental, agricultural and food quality management. They detect the analytes by means of the strong interactions between antibodies and antigens, which provide concentration-dependent signals. For the herein highlighted voltammetric immunosensors, the analytical measurements are due to changes in the electrical signals on the surface of the transducers. The possibility of using disposable and miniaturized immunoassays is a very interesting alternative for voltammetric analyses, mainly, when associated with screen-printing technologies (screen-printed electrodes, SPEs), and microfluidic platforms. The aim of this paper is to discuss a carefully selected literature about different examples of SPEs-based immunosensors associated with microfluidic technologies for diseases, food, agricultural and environmental analysis. Technological aspects of the development of the voltammetric immunoassays such as the signal amplification, construction of paper-based microfluidic platforms and the utilization of microfluidic devices for point-of-care testing will be presented as well.
Collapse
Affiliation(s)
- Fabiana S Felix
- Departamento de Química, Universidade Federal de Lavras (UFLA), CP 3037, Lavras, CEP 37200-000 MG, Brazil.
| | - Alexandre L B Baccaro
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, 05508-000 São Paulo, SP, Brazil.
| | - Lúcio Angnes
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, 05508-000 São Paulo, SP, Brazil.
| |
Collapse
|
38
|
Cincotto FH, Fava EL, Moraes FC, Fatibello-Filho O, Faria RC. A new disposable microfluidic electrochemical paper-based device for the simultaneous determination of clinical biomarkers. Talanta 2018; 195:62-68. [PMID: 30625593 DOI: 10.1016/j.talanta.2018.11.022] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 10/31/2018] [Accepted: 11/05/2018] [Indexed: 12/13/2022]
Abstract
A new disposable microfluidic electrochemical paper-based device (ePAD) consisting of two spot sensors in the same working electrode for the simultaneous determination of uric acid and creatinine was developed. The spot 1 surface was modified with graphene quantum dots for direct uric acid oxidation and spot 2 surface modified with graphene quantum dots, creatininase and a ruthenium electrochemical mediator for creatinine oxidation. The ePAD was employed to construct an electrochemical sensor (based on square wave voltammetry analysis) for the simultaneous determination of uric acid and creatinine in the 0.010-3.0 µmol L-1 range. The device showed excellent analytical performance with a very low simultaneous detection limit of 8.4 nmol L-1 to uric acid and 3.7 nmol L-1 to creatinine and high selectivity. The ePAD was applied to the rapid and successful determination of those clinical biomarkers in human urine samples.
Collapse
Affiliation(s)
- Fernando H Cincotto
- Chemistry Department, Federal University of São Carlos, 13565-905 São Carlos, SP, Brazil; Institute of Chemistry, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Elson L Fava
- Chemistry Department, Federal University of São Carlos, 13565-905 São Carlos, SP, Brazil
| | - Fernando C Moraes
- Chemistry Department, Federal University of São Carlos, 13565-905 São Carlos, SP, Brazil
| | | | - Ronaldo C Faria
- Chemistry Department, Federal University of São Carlos, 13565-905 São Carlos, SP, Brazil
| |
Collapse
|
39
|
Kim JJ, Chan PPY, Vlassakis J, Geldert A, Herr AE. Microparticle Delivery of Protein Markers for Single-Cell Western Blotting from Microwells. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1802865. [PMID: 30334351 PMCID: PMC6272123 DOI: 10.1002/smll.201802865] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2018] [Revised: 09/12/2018] [Indexed: 05/04/2023]
Abstract
Immunoblotting confers protein identification specificity beyond that of immunoassays by prepending protein electrophoresis (sizing) to immunoprobing. To accurately size protein targets, sample analysis includes concurrent analysis of protein markers with known molecular masses. To incorporate protein markers in single-cell western blotting, microwells are used to isolate individual cells and protein marker-coated microparticles. A magnetic field directs protein-coated microparticles to >75% of microwells, so as to 1) deliver a quantum of protein marker to each cell-laden microwell and 2) synchronize protein marker solubilization with cell lysis. Nickel-coated microparticles are designed, fabricated, and characterized, each conjugated with a mixture of histidine-tagged proteins (42.3-100 kDa). Imidazole in the cell lysis buffer solubilizes protein markers during a 30 s cell lysis step, with an observed protein marker release half-life of 4.46 s. Across hundreds of individual microwells and different microdevices, robust log-linear regression fits (R2 > 0.97) of protein molecular mass and electrophoretic mobility are observed. The protein marker and microparticle system is applied to determine the molecular masses of five endogenous proteins in breast cancer cells (GAPDH, β-TUB, CK8, STAT3, ER-α), with <20% mass error. Microparticle-delivered protein standards underpin robust, reproducible electrophoretic cytometry that complements single-cell genomics and transcriptomics.
Collapse
Affiliation(s)
- John J. Kim
- Department of Bioengineering, University of California Berkeley, Berkeley, CA 94720, USA; UCB-UCSF Graduate Program in Bioengineering, University of California Berkeley, Berkeley, CA 94720, USA
| | - Peggy P. Y. Chan
- Department of Bioengineering, University of California Berkeley, Berkeley, CA 94720, USA; Faculty of Science Engineering & Technology, Swinburne University of Technology, Melbourne, VIC 3122, Australia
| | - Julea Vlassakis
- Department of Bioengineering, University of California Berkeley, Berkeley, CA 94720, USA; UCB-UCSF Graduate Program in Bioengineering, University of California Berkeley, Berkeley, CA 94720, USA
| | - Alisha Geldert
- Department of Bioengineering, University of California Berkeley, Berkeley, CA 94720, USA; UCB-UCSF Graduate Program in Bioengineering, University of California Berkeley, Berkeley, CA 94720, USA
| | - Amy E. Herr
- Department of Bioengineering, University of California Berkeley, Berkeley, CA 94720, USA, ; UCB-UCSF Graduate Program in Bioengineering, University of California Berkeley, Berkeley, CA 94720, USA; Chan Zuckerberg Biohub, San Francisco, CA 94158, USA
| |
Collapse
|
40
|
Ahirwar R, Dalal A, Sharma JG, Yadav BK, Nahar P, Kumar A, Kumar S. An aptasensor for rapid and sensitive detection of estrogen receptor alpha in human breast cancer. Biotechnol Bioeng 2018; 116:227-233. [PMID: 30132794 DOI: 10.1002/bit.26819] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Revised: 08/01/2018] [Accepted: 08/14/2018] [Indexed: 01/10/2023]
Abstract
The analysis of estrogen receptor (ER) expression in breast carcinomas plays a crucial role in determining the endocrine responsiveness of tumors for systemic adjuvant therapy. Conventionally, the ER levels in breast carcinomas had been detected using the dextran-coated charcoal assay and radioimmunoassay, which are now substituted with safer and economic antibody-based assays such as immunohistochemistry (IHC) and enzyme-linked immunosorbent assay (ELISA). Despite a gold (Au) standard method, the IHC has been criticized for factors such as tissue fixation, antibody selection, and threshold staining for result interpretation that could falsify test accuracy and reproducibility. The quest for alternative methods of ER quantification in tissue samples paved the way for aptamer-based diagnostics. Previously, we have isolated a DNA aptamer against human ER alpha (ERα) using an in vitro evolution system. In this study, we developed an electrochemical sensor using the 76-nucleotide DNA ERα- aptamer for rapid, precise, and cost-effective detection of ERα expression in human breast cancer patients. The aptasensor was constructed by covalently immobilizing the thiolated ERα- aptamer onto a screen-printed Au electrode. Construction of aptasensors was confirmed through atomic force microscopy and differential pulse voltammetry measurements. A detection limit of 0.001 ng/ml was calculated for full-length ERα (66.2 kDa) in a detection time of 10 min. Analysis of the cancerous breast tissue samples using the ELISA and aptasensor methods enabled distinctive classification of samples into the categories of ER -ve, weak ER +ve, and strong ER +ve samples. The current change of this aptasensor lies within 5% after a storage of 60 days at 4°C. Further studies on a reasonably large sample size are required to realize the clinical potential of the sensor.
Collapse
Affiliation(s)
- Rajesh Ahirwar
- Department of Biochemistry, ICMR-National Institute for Research in Environmental Health, Bhopal, India
| | - Anita Dalal
- Department of Biotechnology, Deenbandhu Chhotu Ram University of Science and Technology, Sonipat, India
| | - Jai G Sharma
- Department of Biotechnology, Delhi Technological University, Delhi, India
| | - Birendra K Yadav
- Department of Research, Rajiv Gandhi Cancer Institute and Research Centre, Rohini, New Delhi, India.,Biobank Manager, National Liver Disease Biobank, Institute of Liver and Billary Sciences, Delhi, India
| | - Pradip Nahar
- Department of Chemical and Systems Biology, CSIR-Institute of Genomics and Integrative Biology, Delhi, India
| | - Ashok Kumar
- Department of Chemical and Systems Biology, CSIR-Institute of Genomics and Integrative Biology, Delhi, India
| | - Saroj Kumar
- Department of Biotechnology, Delhi Technological University, Delhi, India
| |
Collapse
|
41
|
Yang Y, Fu Y, Su H, Mao L, Chen M. Sensitive detection of MCF-7 human breast cancer cells by using a novel DNA-labeled sandwich electrochemical biosensor. Biosens Bioelectron 2018; 122:175-182. [PMID: 30265967 DOI: 10.1016/j.bios.2018.09.062] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 09/15/2018] [Accepted: 09/17/2018] [Indexed: 01/23/2023]
Abstract
The simple, rapid, sensitive, and specific detection of cancer cells plays a pivotal role in the diagnosis and prognosis of cancer. We developed a novel DNA-labeled sandwich electrochemical biosensor based on a glassy carbon electrode modified with 3D graphene and a hybrid of Au nanocages (Au NCs)/amino-functionalized multiwalled carbon nanotubes (MWCNT-NH2) for label-free and selective detection of MCF-7 breast cancer cells via differential pulse voltammetry. The layer-by-layer assembly and cell-detection performance of the Au NCs/MWCNTs-NH2-based biosensor were investigated using scanning electron microscopy and electrochemical methods including cyclic voltammetry and electrochemical impedance spectroscopy. Owing to the advantages of DNA-labeled antibodies and a nanomaterial-based signal amplification strategy, the fabricated cytosensor exhibited high specificity and sensitivity when detecting MCF-7 cells in the range of 1.0 × 102 to 1.0 × 106 cells mL-1 with a low detection limit of 80 cells mL-1 (3σ/slope). Furthermore, the biosensor exhibited high selectivity when detecting MCF-7 cells and showed considerable potential for practical applications. The proposed DNA-labeled sandwich electrochemical biosensor provides a stable, sensitive approach to detecting cancer cells and is promising in terms of potential applications to cancer diagnosis.
Collapse
Affiliation(s)
- Yuhan Yang
- School of Biology Science And Technology, Chengdu Medical College, Chengdu, Sichuan 610500, PR China
| | - Yongyao Fu
- School of Advanced Agriculture and Bioengineering, Yangtze Normal University, Fuling District, Chongqing 408100, PR China
| | - Huilan Su
- School of Public Health, Chengdu Medical College, Chengdu 610500, PR China
| | - Li Mao
- School of Public Health, Chengdu Medical College, Chengdu 610500, PR China
| | - Mei Chen
- School of Biology Science And Technology, Chengdu Medical College, Chengdu, Sichuan 610500, PR China.
| |
Collapse
|
42
|
de Oliveira RAG, Nicoliche CYN, Pasqualeti AM, Shimizu FM, Ribeiro IR, Melendez ME, Carvalho AL, Gobbi AL, Faria RC, Lima RS. Low-Cost and Rapid-Production Microfluidic Electrochemical Double-Layer Capacitors for Fast and Sensitive Breast Cancer Diagnosis. Anal Chem 2018; 90:12377-12384. [DOI: 10.1021/acs.analchem.8b02605] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Ricardo A. G. de Oliveira
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brasil
| | - Caroline Y. N. Nicoliche
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brasil
| | - Anielli M. Pasqualeti
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brasil
| | - Flavio M. Shimizu
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brasil
| | - Iris R. Ribeiro
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brasil
- Instituto de Química, Universidade Estadual de Campinas, Campinas, São Paulo 13083-970, Brasil
| | - Matias E. Melendez
- Centro de Pesquisa em Oncologia Molecular, Hospital de Câncer de Barretos, Barretos, São Paulo 14784-400, Brasil
| | - André L. Carvalho
- Centro de Pesquisa em Oncologia Molecular, Hospital de Câncer de Barretos, Barretos, São Paulo 14784-400, Brasil
| | - Angelo L. Gobbi
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brasil
| | - Ronaldo C. Faria
- Departamento de Química, Universidade Federal de São Carlos, São Carlos, São Paulo 13565-905, Brasil
| | - Renato S. Lima
- Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brasil
- Instituto de Química, Universidade Estadual de Campinas, Campinas, São Paulo 13083-970, Brasil
| |
Collapse
|
43
|
Mohammadi S, Salimi A, Hamd-Ghadareh S, Fathi F, Soleimani F. A FRET immunosensor for sensitive detection of CA 15-3 tumor marker in human serum sample and breast cancer cells using antibody functionalized luminescent carbon-dots and AuNPs-dendrimer aptamer as donor-acceptor pair. Anal Biochem 2018; 557:18-26. [PMID: 29908158 DOI: 10.1016/j.ab.2018.06.008] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Revised: 06/12/2018] [Accepted: 06/12/2018] [Indexed: 11/30/2022]
Abstract
We proposed a FRET immunosensing for detection of CA15-3 tumor marker by highly biospecific interactions between CA 15-3 antigen and the corresponding antibody and aptamer. In this sandwich type immunoassay, CA15-3 antibody-functionalized carbon dots and AuNPs labeled PAMAM-Dendrimer/aptamer were used as donor/acceptor, respectively. When CA 15-3 Ag was added to homogenous immunoassay, the strong complex interaction between CA15-3 Ab-CA15-3 Ag- aptamer caused in more coming closer carbon dot and AuNPs and more decreasing fluorescence signal. The decreased fluorescence intensity was linear at three ranges including in concentration range 1.1 μUmL-1 to 16 μU mL-1 with regression of R2 = 0.9879, at the concentration range 16 μU mL-1 to 0.163 mU mL-1 with regression of R2 = 0.9944 and at the concentration range 0.163 mU mL-1 to 5.0 mU mL-1 with regression of R2 = 0.9805. The detection limit of the FRET immunoassay was 0.9 μU mL-1. This assay revealed good sensitivity and specificity with MDA-MB-231 breast cancer cells concentrations from 1000 to 40000 cells/mL with correlation coefficient of 0.9955 and detection limit of 300 cells/mL (3 cells in 10 μL of injected sample). In addition, this FRET immunosensing is applicable in diluted human serum. The recovery values were in the range of 95.86-96.97% for CA 15-3 Ag in spiked serum sample with RSD lower than 7.3%. The proposed immunoassay could be a valid model for establishing other immunoassays for detection of different cancer tumor markers with relevant antigens and antibodies.
Collapse
Affiliation(s)
- Somayeh Mohammadi
- Department of Chemistry, University of Kurdistan, 66177-15175, Sanandaj, Iran
| | - Abdollah Salimi
- Department of Chemistry, University of Kurdistan, 66177-15175, Sanandaj, Iran; Research Center for Nanotechnology, University of Kurdistan, 66177-15175, Sanandaj, Iran.
| | | | - Fardin Fathi
- Cellular and Molecular Reserch Center, Kurdistan University of Medical Sciences, 66177-13446 Sananandaj, Iran
| | - Farzad Soleimani
- Cellular and Molecular Reserch Center, Kurdistan University of Medical Sciences, 66177-13446 Sananandaj, Iran
| |
Collapse
|
44
|
Carvajal S, Fera SN, Jones AL, Baldo TA, Mosa IM, Rusling JF, Krause CE. Disposable inkjet-printed electrochemical platform for detection of clinically relevant HER-2 breast cancer biomarker. Biosens Bioelectron 2018; 104:158-162. [PMID: 29331430 DOI: 10.1016/j.bios.2018.01.003] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 12/21/2017] [Accepted: 01/03/2018] [Indexed: 10/18/2022]
Abstract
Rapidly fabricated, disposable sensor platforms hold tremendous promise for point-of-care detection. Here, we present an inexpensive (< $0.25) fully inkjet printed electrochemical sensor with integrated counter, reference, and working electrodes that is easily scalable for commercial fabrication. The electrochemical sensor platform featured an inkjet printed gold working 8-electrode array (WEA) and counter electrode (CE), along with an inkjet -printed silver electrode that was chlorinated with bleach to produce a Ag/AgCl quasi-reference electrode (RE). As proof of concept, the electrochemical sensor was successfully applied for detection of clinically relevant breast cancer biomarker Human Epidermal Growth Factor Receptor 2 (HER-2). Capture antibodies were bound to a chemically modified surface on the WEA and placed into a microfluidic device. A full sandwich immunoassay was constructed following a simultaneous injection of target protein, biotinylated antibody, and polymerized horseradish peroxide labels into the microfluidic device housing the WEA. With an ultra fast assay time, of only 15mins a clinically relevant limit of detection of 12pgmL-1 was achieved. Excellent reproducibility and sensitivity were observed through recovery assays preformed in human serum with recoveries ranging from 76% to 103%. These easily fabricated and scalable electrochemical sensor platforms can be readily adapted for multiplex detection following this rapid assay protocol for cancer diagnostics.
Collapse
Affiliation(s)
- Susanita Carvajal
- Department of Chemistry, University of Hartford, Bloomfield Ave., West Hartford, CT 06117, USA
| | - Samantha N Fera
- Department of Chemistry, University of Hartford, Bloomfield Ave., West Hartford, CT 06117, USA
| | - Abby L Jones
- Department of Chemistry, University of Connecticut, 55 North Eagleville Rd., Storrs, CT 06269, USA
| | - Thaisa A Baldo
- Department of Chemistry, Federal University of São Carlos, São Carlos 13565-905, SP, Brazil
| | - Islam M Mosa
- Department of Chemistry, University of Connecticut, 55 North Eagleville Rd., Storrs, CT 06269, USA; Department of Chemistry, Tanta University, Tanta 31527, Egypt
| | - James F Rusling
- Department of Chemistry, University of Connecticut, 55 North Eagleville Rd., Storrs, CT 06269, USA; Department of Surgery & Neag Cancer Center, UConn, Health, 263 Farmington Avenue, Farmington, CT 06030, USA; Institute of Materials Science, University of Connecticut, 97 North Eagleville Road, Storrs, CT 06269, USA; School of Chemistry, National University of Ireland, University Road, Galway Ireland, Ireland
| | - Colleen E Krause
- Department of Chemistry, University of Hartford, Bloomfield Ave., West Hartford, CT 06117, USA.
| |
Collapse
|