1
|
Ehtiati S, Naeeni B, Qeysouri B, Heidarian E, Azmon M, Ahmadzade R, Movahedpour A, Kazemi F, Motamedzadeh A, Khatami SH. Electrochemical biosensors in early leukemia detection. Clin Chim Acta 2024; 562:119871. [PMID: 39009333 DOI: 10.1016/j.cca.2024.119871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 07/11/2024] [Accepted: 07/12/2024] [Indexed: 07/17/2024]
Abstract
Leukemia, a type of blood cancer marked by an abnormal increase in white blood cells, poses a significant challenge to healthcare. The key to successful treatment lies in early detection. However, traditional methods often fall short. This review investigates the potential of electrochemical biosensors for a more accurate and earlier diagnosis of leukemia. Electrochemical biosensors are compact devices that transform biological interactions into electrical signals. Their small size, ease of use, and minimal sample requirements make them perfectly suited for point-of-care applications. Their remarkable sensitivity and specificity enable the detection of subtle biomolecular changes associated with leukemia, which is crucial for early disease detection. This review delves into studies that have utilized these biosensors to identify various types of leukemia. It examines the roles of electrodes, biorecognition elements, and signal transduction mechanisms. The discussion includes the integration of nanomaterials such as gold nanoparticles and nitrogen-doped graphene into biosensor design. These materials boost sensitivity, enhance signal amplification, and facilitate multi-analyte detection, thereby providing a more holistic view of the disease. Beyond technical advancements, the review underscores the practical benefits of these biosensors. Their portability makes them a promising tool for resource-constrained settings, enabling swift diagnosis in remote areas or at a patient's bedside. The potential for monitoring treatment effectiveness and detecting minimal residual disease to prevent relapse is also explored. This review emphasizes the transformative potential of electrochemical biosensors in combating leukemia. By facilitating earlier and more accurate diagnosis, these biosensors stand to revolutionize patient care and enhance treatment outcomes.
Collapse
Affiliation(s)
- Sajad Ehtiati
- Student Research Committee, Department of Clinical Biochemistry, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Bahareh Naeeni
- Department of Clinical Biochemistry, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - Bahram Qeysouri
- Department of Clinical Biochemistry, Medical School, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Erfan Heidarian
- Department of Clinical Biochemistry, Faculty of Medicine, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Marzyeh Azmon
- Department of Internal Medicine, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Reyhane Ahmadzade
- Department of Clinical Biochemistry, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | | | - Fatemeh Kazemi
- Metabolic Diseases Research Center, Institute for Prevention of Non-communicable Diseases, Qazvin University of Medical Sciences, Qazvin, Iran.
| | - Alireza Motamedzadeh
- Department of Internal Medicine, Faculty of Medicine, Kashan University of Medical Sciences, Kashan, Iran.
| | - Seyyed Hossein Khatami
- Student Research Committee, Department of Clinical Biochemistry, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
2
|
Anthi J, Vaněčková E, Spasovová M, Houska M, Vrabcová M, Vogelová E, Holubová B, Vaisocherová-Lísalová H, Kolivoška V. Probing charge transfer through antifouling polymer brushes by electrochemical methods: The impact of supporting self-assembled monolayer chain length. Anal Chim Acta 2023; 1276:341640. [PMID: 37573118 DOI: 10.1016/j.aca.2023.341640] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 07/10/2023] [Accepted: 07/17/2023] [Indexed: 08/14/2023]
Abstract
Ultrathin surface-tethered polymer brushes represent attractive platforms for a wide range of sensing applications in strategically vital areas such as medicine, forensics, or security. The recent trends in such developments towards "real world conditions" highlighted the role of zwitterionic poly(carboxybetaine) (pCB) brushes which provide excellent antifouling properties combined with bio-functionalization capacity. Highly dense pCB brushes are usually prepared by the "grafting from" polymerization triggered by initiators on self-assembled monolayers (SAMs). Here, multi-methodological experimental studies are pursued to elucidate the impact of the alkanethiolate SAM chain length (C6, C8 and C11) on structural and functional properties of antifouling poly(carboxybetaine methacrylamide) (pCBMAA) brush. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in a custom-made 3D printed cell employing [Ru(NH3)6]3+/2+ redox probe were used to investigate penetrability of SAM/pCBMAA bilayers for small molecules and interfacial charge transfer characteristics. The biofouling resistance of pCBMAA brushes was characterized by surface plasmon resonance; ellipsometry and FT-IRRAS spectroscopy were used to determine swelling and relative density of the brushes synthesized from initiator-bearing SAMs with varied carbon chain length. The SAM length was found to have a substantial impact on all studied characteristics; the highest value of charge transfer resistance (Rct) was observed for denser pCBMAA on longer-chain (C11) SAM when compared to shorter (C8/C6) SAMs. The observed high value of Rct for C11 implies a limitation for the analytical performance of electrochemical sensing methods. At the same time, the pCBMAA brushes on C11 SAM exhibited the best bio-fouling resistance among inspected systems. This demonstrates that proper selection of supporting structures for brushes is critical in the design of these assemblies for biosensing applications.
Collapse
Affiliation(s)
- Judita Anthi
- FZU - Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 00, Prague, Czech Republic; Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 3, 166 28, Prague, Czech Republic
| | - Eva Vaněčková
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23, Prague, Czech Republic
| | - Monika Spasovová
- FZU - Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 00, Prague, Czech Republic
| | - Milan Houska
- FZU - Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 00, Prague, Czech Republic
| | - Markéta Vrabcová
- FZU - Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 00, Prague, Czech Republic
| | - Eva Vogelová
- FZU - Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 00, Prague, Czech Republic
| | - Barbora Holubová
- Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 3, 166 28, Prague, Czech Republic
| | - Hana Vaisocherová-Lísalová
- FZU - Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 00, Prague, Czech Republic.
| | - Viliam Kolivoška
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23, Prague, Czech Republic.
| |
Collapse
|
3
|
Wei L, Wang S, Shan M, Li Y, Wang Y, Wang F, Wang L, Mao J. Conductive fibers for biomedical applications. Bioact Mater 2023; 22:343-364. [PMID: 36311045 PMCID: PMC9588989 DOI: 10.1016/j.bioactmat.2022.10.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 09/12/2022] [Accepted: 10/07/2022] [Indexed: 11/26/2022] Open
Abstract
Bioelectricity has been stated as a key factor in regulating cell activity and tissue function in electroactive tissues. Thus, various biomedical electronic constructs have been developed to interfere with cell behaviors to promote tissue regeneration, or to interface with cells or tissue/organ surfaces to acquire physiological status via electrical signals. Benefiting from the outstanding advantages of flexibility, structural diversity, customizable mechanical properties, and tunable distribution of conductive components, conductive fibers are able to avoid the damage-inducing mechanical mismatch between the construct and the biological environment, in return to ensure stable functioning of such constructs during physiological deformation. Herein, this review starts by presenting current fabrication technologies of conductive fibers including wet spinning, microfluidic spinning, electrospinning and 3D printing as well as surface modification on fibers and fiber assemblies. To provide an update on the biomedical applications of conductive fibers and fiber assemblies, we further elaborate conductive fibrous constructs utilized in tissue engineering and regeneration, implantable healthcare bioelectronics, and wearable healthcare bioelectronics. To conclude, current challenges and future perspectives of biomedical electronic constructs built by conductive fibers are discussed.
Collapse
Affiliation(s)
- Leqian Wei
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| | - Shasha Wang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| | - Mengqi Shan
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| | - Yimeng Li
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| | - Yongliang Wang
- School of Health and Life Sciences, University of Health and Rehabilitation Sciences, Qingdao City, Shandong Province, 266071, China
| | - Fujun Wang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| | - Lu Wang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| | - Jifu Mao
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| |
Collapse
|
4
|
Allegra A, Petrarca C, Di Gioacchino M, Mirabile G, Gangemi S. Electrochemical Biosensors in the Diagnosis of Acute and Chronic Leukemias. Cancers (Basel) 2022; 15:cancers15010146. [PMID: 36612142 PMCID: PMC9817807 DOI: 10.3390/cancers15010146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 12/22/2022] [Accepted: 12/23/2022] [Indexed: 12/28/2022] Open
Abstract
Until now, morphological assessment with an optical or electronic microscope, fluorescence in situ hybridization, DNA sequencing, flow cytometry, polymerase chain reactions, and immunohistochemistry have been employed for leukemia identification. Nevertheless, despite their numerous different vantages, it is difficult to recognize leukemic cells correctly. Recently, the electrochemical evaluation with a nano-sensing interface seems an attractive alternative. Electrochemical biosensors measure the modification in the electrical characteristics of the nano-sensing interface, which is modified by the contact between a biological recognition element and the analyte objective. The implementation of nanosensors is founded not on single nanomaterials but rather on compilating these components efficiently. Biosensors able to identify the molecules of deoxyribonucleic acid are defined as DNA biosensors. Our review aimed to evaluate the literature on the possible use of electrochemical biosensors for identifying hematological neoplasms such as acute promyelocytic leukemia, acute lymphoblastic leukemia, and chronic myeloid leukemia. In particular, we focus our attention on using DNA electrochemical biosensors to evaluate leukemias.
Collapse
Affiliation(s)
- Alessandro Allegra
- Division of Hematology, Department of Human Pathology in Adulthood and Childhood “Gaetano Barresi”, University of Messina, 98125 Messina, Italy
| | - Claudia Petrarca
- Department of Medicine and Aging Sciences, G. D’Annunzio University, 66100 Chieti, Italy
- Center for Advanced Studies and Technology, G. D’Annunzio University, 66100 Chieti, Italy
- Correspondence:
| | - Mario Di Gioacchino
- Institute for Clinical Immunotherapy and Advanced Biological Treatments, 65100 Pescara, Italy
| | - Giuseppe Mirabile
- Division of Hematology, Department of Human Pathology in Adulthood and Childhood “Gaetano Barresi”, University of Messina, 98125 Messina, Italy
| | - Sebastiano Gangemi
- Unit of Allergy and Clinical Immunology, Department of Clinical and Experimental Medicine, School of Allergy and Clinical Immunology, University of Messina, 98125 Messina, Italy
| |
Collapse
|
5
|
Acosta M, Santiago MD, Irvin JA. Electrospun Conducting Polymers: Approaches and Applications. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15248820. [PMID: 36556626 PMCID: PMC9782039 DOI: 10.3390/ma15248820] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 12/02/2022] [Accepted: 12/03/2022] [Indexed: 05/14/2023]
Abstract
Inherently conductive polymers (CPs) can generally be switched between two or more stable oxidation states, giving rise to changes in properties including conductivity, color, and volume. The ability to prepare CP nanofibers could lead to applications including water purification, sensors, separations, nerve regeneration, wound healing, wearable electronic devices, and flexible energy storage. Electrospinning is a relatively inexpensive, simple process that is used to produce polymer nanofibers from solution. The nanofibers have many desirable qualities including high surface area per unit mass, high porosity, and low weight. Unfortunately, the low molecular weight and rigid rod nature of most CPs cannot yield enough chain entanglement for electrospinning, instead yielding polymer nanoparticles via an electrospraying process. Common workarounds include co-extruding with an insulating carrier polymer, coaxial electrospinning, and coating insulating electrospun polymer nanofibers with CPs. This review explores the benefits and drawbacks of these methods, as well as the use of these materials in sensing, biomedical, electronic, separation, purification, and energy conversion and storage applications.
Collapse
Affiliation(s)
- Mariana Acosta
- Materials Science, Engineering and Commercialization Program, Texas State University, San Marcos, TX 78666, USA
| | - Marvin D. Santiago
- Department of Chemistry and Biochemistry, Texas State University, San Marcos, TX 78666, USA
| | - Jennifer A. Irvin
- Materials Science, Engineering and Commercialization Program, Texas State University, San Marcos, TX 78666, USA
- Department of Chemistry and Biochemistry, Texas State University, San Marcos, TX 78666, USA
- Correspondence:
| |
Collapse
|
6
|
Ashraf J, Akbarinejad A, Hisey CL, Bryant DT, Wang J, Zhu B, Evans CW, Williams DE, Chamley LW, Barker D, Pilkington LI, Travas-Sejdic J. Conducting Polymer-Coated Carbon Cloth Captures and Releases Extracellular Vesicles by a Rapid and Controlled Redox Process. ACS APPLIED MATERIALS & INTERFACES 2022; 14:32880-32889. [PMID: 35820023 DOI: 10.1021/acsami.2c06481] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Electrochemical techniques offer great opportunities for the capture of chemical and biological entities from complex mixtures and their subsequent release into clean buffers for analysis. Such methods are clean, robust, rapid, and compatible with a wide range of biological fluids. Here, we designed an electrochemically addressable system, based on a conducting terpolymer [P(EDOT-co-EDOTSAc-co-EDOTEG)] coated onto a carbon cloth substrate, to selectively capture and release biological entities using a simple electrochemical redox process. The conducting terpolymer composition was optimized and the terpolymer-coated carbon cloth was extensively characterized using electrochemical analysis, Raman and Fourier transform-infrared spectroscopy, water contact angle analysis, and scanning electron microscopy. The conductive terpolymer possesses a derivative of EDOT with an acetylthiomethyl moiety (EDOTSAc), which is converted into a "free" thiol that then undergoes reversible oxidation/reduction cycles at +1.0 V and -0.8 V (vs Ag/AgCl), respectively. That redox process enables electrochemical capture and on-demand release. We first demonstrated the successful electrochemical capture/release of a fluorescently labeled IgG antibody. The same capture/release procedure was then applied to release extracellular vesicles (EVs), originating from both MCF7 and SKBR3 breast cancer cell line bioreactors. EVs were captured using the substrate-conjugated HER2 antibody which was purified from commercially available trastuzumab. Capture and release of breast cancer EVs using a trastuzumab-derived HER2 antibody has not been reported before (to the best of our knowledge). A rapid (2 min) release at a low potential (-0.8 V) achieved a high release efficiency (>70%) of the captured, HER2+ve, SKBR3 EVs. The developed system and the electrochemical method are efficient and straightforward and have vast potential for the isolation and concentration of various biological targets from large volumes of biological and other (e.g., environmental) samples.
Collapse
Affiliation(s)
- Jesna Ashraf
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Alireza Akbarinejad
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Colin L Hisey
- Hub for Extracellular Vesicles Investigations (HEVI), Department of Obstetrics and Gynaecology, The University of Auckland, Auckland 1023, New Zealand
| | - Devon T Bryant
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
| | - Julie Wang
- Hub for Extracellular Vesicles Investigations (HEVI), Department of Obstetrics and Gynaecology, The University of Auckland, Auckland 1023, New Zealand
| | - Bicheng Zhu
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Clive W Evans
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- School of Biological Sciences, The University of Auckland, Auckland 1010, New Zealand
| | - David E Williams
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Lawrence W Chamley
- Hub for Extracellular Vesicles Investigations (HEVI), Department of Obstetrics and Gynaecology, The University of Auckland, Auckland 1023, New Zealand
| | - David Barker
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Lisa I Pilkington
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
| | - Jadranka Travas-Sejdic
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| |
Collapse
|
7
|
Anthi J, Kolivoška V, Holubová B, Vaisocherová-Lísalová H. Probing polymer brushes with electrochemical impedance spectroscopy: a mini review. Biomater Sci 2021; 9:7379-7391. [PMID: 34693954 DOI: 10.1039/d1bm01330k] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Polymer brushes are frequently used as surface-tethered antifouling layers in biosensors to improve sensor surface-analyte recognition in the presence of abundant non-target molecules in complex biological samples by suppressing nonspecific interactions. However, because brushes are complex systems highly responsive to changes in their surrounding environment, studying their properties remains a challenge. Electrochemical impedance spectroscopy (EIS) is an emerging method in this context. In this mini review, we aim to elucidate the potential of EIS for investigating the physicochemical properties and structural aspects of polymer brushes. The application of EIS in brush-based biosensors is also discussed. Most common principles employed in these biosensors are presented, as well as interpretation of EIS data obtained in such setups. Overall, we demonstrate that the EIS-polymer brush pairing has a considerable potential for providing new insights into brush functionalities and designing highly sensitive and specific biosensors.
Collapse
Affiliation(s)
- Judita Anthi
- Institute of Physics of the CAS, Na Slovance 2, 182 21 Prague, Czech Republic. .,Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 3, 16628 Prague, Czech Republic
| | - Viliam Kolivoška
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23 Prague, Czech Republic.
| | - Barbora Holubová
- Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 3, 16628 Prague, Czech Republic
| | | |
Collapse
|
8
|
Cheema JA, Carraher C, Plank NOV, Travas-Sejdic J, Kralicek A. Insect odorant receptor-based biosensors: Current status and prospects. Biotechnol Adv 2021; 53:107840. [PMID: 34606949 DOI: 10.1016/j.biotechadv.2021.107840] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 09/02/2021] [Accepted: 09/27/2021] [Indexed: 02/01/2023]
Abstract
Whilst the senses of vision and hearing have been successfully automated and miniaturized in portable formats (e.g. smart phone), this is yet to be achieved with the sense of smell. This is because the sensing challenge is not trivial as it involves navigating a chemosensory space comprising thousands of volatile organic compounds. Distinct aroma recognition is based on detecting unique combinations of volatile organic compounds. In natural olfactory systems this is accomplished by employing odorant receptors (ORs) with varying specificities, together with combinatorial neural coding mechanisms. Attempts to mimic the remarkable sensitivity and accuracy of natural olfactory systems has therefore been challenging. Current portable chemical sensors for odorant detection are neither sensitive nor selective, prompting research exploring artificial olfactory devices that use natural OR proteins for sensing. Much research activity to develop OR based biosensors has concentrated on mammalian ORs, however, insect ORs have not been explored as extensively. Insects possess an extraordinary sense of smell due to a repertoire of odorant receptors evolved to interpret olfactory cues vital to the insects' survival. The potential of insect ORs as sensing elements is only now being unlocked through recent research efforts to understand their structure, ligand binding mechanisms and development of odorant biosensors. Like their mammalian counterparts, there are many challenges with working with insect ORs. These include expression, purification and presentation of the insect OR in a stable display format compatible with an effective transduction methodology while maintaining OR structure and function. Despite these challenges, significant progress has been demonstrated in developing OR-based biosensors which exploit insect ORs in cells, lipid bilayers, liposomes and nanodisc formats. Ultrasensitive and highly selective detection of volatile organic compounds has been validated by coupling these insect OR display formats with transduction methodologies spanning optical (fluorescence) and electrical (field effect transistors, electrochemical impedance spectroscopy) techniques. This review summarizes the current status of insect OR based biosensors and their future outlook.
Collapse
Affiliation(s)
- Jamal Ahmed Cheema
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1023, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington 6140, New Zealand; The New Zealand Institute for Plant and Food Research Limited, Private Bag 92169, Auckland 1142, New Zealand
| | - Colm Carraher
- The New Zealand Institute for Plant and Food Research Limited, Private Bag 92169, Auckland 1142, New Zealand
| | - Natalie O V Plank
- MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington 6140, New Zealand; School of Chemical and Physical Sciences, Victoria University of Wellington, Wellington 6021, New Zealand
| | - Jadranka Travas-Sejdic
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1023, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington 6140, New Zealand.
| | - Andrew Kralicek
- The New Zealand Institute for Plant and Food Research Limited, Private Bag 92169, Auckland 1142, New Zealand; Scentian Bio Limited, 1c Goring Road, Sandringham, Auckland 1025, New Zealand.
| |
Collapse
|
9
|
Zhang Y, Wang X, Fang X, Yuan X, Yang H, Kong J. Label-free electrochemical immunoassay for detecting CYFRA 21-1 using poly(ε-caprolactone)-b-poly(ethylene oxide) block copolymer. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106119] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
10
|
|
11
|
Flores-Hernandez DR, Santamaria-Garcia VJ, Melchor-Martínez EM, Sosa-Hernández JE, Parra-Saldívar R, Bonilla-Rios J. Paper and Other Fibrous Materials-A Complete Platform for Biosensing Applications. BIOSENSORS 2021; 11:128. [PMID: 33919464 PMCID: PMC8143474 DOI: 10.3390/bios11050128] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 04/02/2021] [Accepted: 04/06/2021] [Indexed: 01/22/2023]
Abstract
Paper-based analytical devices (PADs) and Electrospun Fiber-Based Biosensors (EFBs) have aroused the interest of the academy and industry due to their affordability, sensitivity, ease of use, robustness, being equipment-free, and deliverability to end-users. These features make them suitable to face the need for point-of-care (POC) diagnostics, monitoring, environmental, and quality food control applications. Our work introduces new and experienced researchers in the field to a practical guide for fibrous-based biosensors fabrication with insight into the chemical and physical interaction of fibrous materials with a wide variety of materials for functionalization and biofunctionalization purposes. This research also allows readers to compare classical and novel materials, fabrication techniques, immobilization methods, signal transduction, and readout. Moreover, the examined classical and alternative mathematical models provide a powerful tool for bioanalytical device designing for the multiple steps required in biosensing platforms. Finally, we aimed this research to comprise the current state of PADs and EFBs research and their future direction to offer the reader a full insight on this topic.
Collapse
Affiliation(s)
| | | | | | | | | | - Jaime Bonilla-Rios
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Avenida Eugenio Garza Sada 2501, Monterrey 64849, NL, Mexico; (D.R.F.-H.); (V.J.S.-G.); (E.M.M.-M.); (J.E.S.-H.); (R.P.-S.)
| |
Collapse
|
12
|
Li X, Zhang Y, Hao L, Liu Y, Wang X, Yang H, Kong J. Ultrasensitive label-free detection for lung cancer CYFRA 21-1 DNA based on ring-opening polymerization. Talanta 2021; 223:121730. [PMID: 33298260 DOI: 10.1016/j.talanta.2020.121730] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Revised: 09/30/2020] [Accepted: 10/02/2020] [Indexed: 02/07/2023]
Abstract
Cytokeratin fragment antigen 21-1 (CYFRA 21-1) DNA is perceived as sensitive tumor marker for the diagnosis of non-small cell lung cancer and other tumor. Herein, linear chain poly(ε-caprolactone) (PCL) synthesized by ring-opening polymerization is applied to ultrasensitive label-free electrochemical impedance detection system for CYFRA 21-1 DNA. First, thiolated peptide nucleic acid (PNA) is self-assembled into the Au electrode surface through the formation of Au-S bonds, allowing the PNA to act as biomolecular probe and form PNA/DNA heteroduplex with the target DNA via specific hybridization. Then, PCL is conjugated to the immobilized DNA on the electrode via "carboxylate-Zr4+-phosphate" bridges. Finally, the electrochemical response of modified PNA/DNA/Zr4+/PCL electrode is determined by electrochemical impedance method to quantify of CYFRA 21-1 DNA. Under optimal conditions, this method exhibits highly sensitivity with a broad linear range (0.1 fM - 1 nM) (R2 = 0.995) and the limit of detection (LOD) is as low as 10.73 aM, which is equivalent to just 64 molecules in a 10 μL sample. What's more, the high selectivity, good anti-interference, label-free operation, and real-time monitoring in complex samples of the proposed strategy demonstrate its broad application for the early diagnosis and clinical monitoring.
Collapse
Affiliation(s)
- Xiaofei Li
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China
| | - Yawen Zhang
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China
| | - Lulu Hao
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China
| | - Yanju Liu
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China
| | - Xia Wang
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China.
| | - Huaixia Yang
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China.
| | - Jinming Kong
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, 210094, PR China.
| |
Collapse
|
13
|
Molina BG, Bendrea AD, Lanzalaco S, Franco L, Cianga L, Del Valle LJ, Puiggali J, Turon P, Armelin E, Cianga I, Aleman C. Smart design for a flexible, functionalized and electroresponsive hybrid platform based on poly(3,4-ethylenedioxythiophene) derivatives to improve cell viability. J Mater Chem B 2020; 8:8864-8877. [PMID: 33026390 DOI: 10.1039/d0tb01259a] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Development of smart functionalized materials for tissue engineering has attracted significant attention in recent years. In this work we have functionalized a free-standing film of isotactic polypropylene (i-PP), a synthetic polymer that is typically used for biomedical applications (e.g. fabrication of implants), for engineering a 3D all-polymer flexible interface that enhances cell proliferation by a factor of ca. three. A hierarchical construction process consisting of three steps was engineered as follows: (1) functionalization of i-PP by applying a plasma treatment, resulting in i-PPf; (2) i-PPf surface coating with a layer of polyhydroxymethy-3,4-ethylenedioxythiophene nanoparticles (PHMeEDOT NPs) by in situ chemical oxidative polymerization of HMeEDOT; and (3) deposition on the previously activated and PHMeEDOT NPs coated i-PP film (i-PPf/NP) of a graft conjugated copolymer, having a poly(3,4-ethylenedioxythiophene) (PEDOT) backbone, and randomly distributed short poly(ε-caprolactone) (PCL) side chains (PEDOT-g-PCL), as a coating layer of ∼9 μm in thickness. The properties of the resulting bioplatform, which can be defined as a robust macroscopic composite coated with a "molecular composite", were investigated in detail, and both adhesion and proliferation of two human cell lines have been evaluated, as well. The results demonstrate that the incorporation of the PEDOT-g-PCL layer significantly improves cell attachment and cell growth not only when compared to i-PP but also with respect to the same platform coated with only PEDOT, constructed in a similar manner, as a control.
Collapse
Affiliation(s)
- Brenda G Molina
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, Ed. I2, 08019, Barcelona, Spain.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Akbarinejad A, Hisey CL, Brewster D, Ashraf J, Chang V, Sabet S, Nursalim Y, Lucarelli V, Blenkiron C, Chamley L, Barker D, Williams DE, Evans CW, Travas-Sejdic J. Novel Electrochemically Switchable, Flexible, Microporous Cloth that Selectively Captures, Releases, and Concentrates Intact Extracellular Vesicles. ACS APPLIED MATERIALS & INTERFACES 2020; 12:39005-39013. [PMID: 32805904 DOI: 10.1021/acsami.0c11908] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
There is a significant and growing research interest in the isolation of extracellular vesicles (EVs) from large volumes of biological samples and their subsequent concentration into clean and small volumes of buffers, especially for applications in medical diagnostics. Materials that are easily incorporated into simple sampling devices and which allow the release of EVs without the need for auxiliary and hence contaminating reagents are particularly in demand. Herein, we report on the design and fabrication of a flexible, microporous, electrochemically switchable cloth that addresses the key challenges in diagnostic applications of EVs. We demonstrate the utility of our electrochemically switchable substrate for the fast, selective, nondestructive, and efficient capture and subsequent release of EVs. The substrate consists of an electrospun cloth, infused with a conducting polymer and decorated with gold particles. Utilizing gold-sulfur covalent bonding, the electrospun substrates may be functionalized with SH-terminated aptamer probes selective to EV surface proteins. We demonstrate that EVs derived from primary human dermal fibroblast (HDFa) and breast cancer (MCF-7) cell lines are selectively captured with low nonspecific adsorption using an aptamer specific to the CD63 protein expressed on the EV membranes. The specific aptamer-EV interactions enable easy removal of the nonspecifically bound material through washing steps. The conducting polymer component of the cloth provides a means for efficient (>92%) and fast (<5 min) electrochemical release of clean and intact captured EVs by cathodic cleavage of the Au-S bond. We demonstrate successful capture of diluted EVs from a large volume sample and their release into a small volume of clean phosphate-buffered saline buffer. The developed cloth can easily be incorporated into different designs for separation systems and would be adaptable to other biological entities including cells and other EVs. Furthermore, the capture/release capability holds great promise for liquid biopsies if used to targeted disease-specific markers.
Collapse
Affiliation(s)
- Alireza Akbarinejad
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Colin L Hisey
- Hub for Extracellular Vesicles Investigations (HEVI), Department of Obstetrics and Gynecology, The University of Auckland, Auckland 1023, New Zealand
| | - Diane Brewster
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The New Zealand Institute for Plant and Food Research Limited, Private Bag 92169, Auckland 1142, New Zealand
| | - Jesna Ashraf
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
| | - Vanessa Chang
- Hub for Extracellular Vesicles Investigations (HEVI), Department of Obstetrics and Gynecology, The University of Auckland, Auckland 1023, New Zealand
| | - Saman Sabet
- School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
| | - Yohanes Nursalim
- Hub for Extracellular Vesicles Investigations (HEVI), Department of Obstetrics and Gynecology, The University of Auckland, Auckland 1023, New Zealand
| | - Valentina Lucarelli
- The New Zealand Institute for Plant and Food Research Limited, Private Bag 92169, Auckland 1142, New Zealand
| | - Cherie Blenkiron
- Hub for Extracellular Vesicles Investigations (HEVI), Department of Obstetrics and Gynecology, The University of Auckland, Auckland 1023, New Zealand
| | - Larry Chamley
- Hub for Extracellular Vesicles Investigations (HEVI), Department of Obstetrics and Gynecology, The University of Auckland, Auckland 1023, New Zealand
| | - David Barker
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - David E Williams
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Clive W Evans
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
| | - Jadranka Travas-Sejdic
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute of Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| |
Collapse
|
15
|
Chen X, Wu Y, Cao G, Wang X, Ji Z, Huo D, Xu F, Hou C. A Methodology for Ultrasensitive Detection of Sequence-Specific DNA or Uracil-DNA Glycosylase Activity. ACS Sens 2020; 5:1615-1623. [PMID: 32375473 DOI: 10.1021/acssensors.0c00081] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Ultrasensitive detection of sequence-specific DNA and uracil-DNA glycosylase (UDG) activity shows great practical significance in clinical diagnostic and biomedical studies. Here, a methodology based on a CRISPR/Cas12a system coupled with enhanced strand displacement amplification (E-SDA) was innovatively established for sequence-specific DNA or UDG activity detection. Sequence-specific DNA or DNA primers processed by UDG and Endonuclease IV can initiate E-SDA, generating auxiliary DNA chains, which act as activators to unlock the indiscriminate collateral cleavage activities (trans-cleavage) of the CRISPR/Cas12a. Then, the activated CRISPR/Cas12a, which intrinsically possesses the ability of significant signal amplification, can indiscriminately cleave the added cleavage reporters in the system. Thus, the multistep amplification of the method was obtained. Under the selected experimental conditions, the established method can achieve an actual sensitivity of sequence-specific DNA up to 100 aM within 2.5 h or ultralow UDG activity (3.1×10-5 U/mL) detection within 3.5 h. We believe that the proposed method will have great potential for practical application in ultrasensitive detection of sequence-specific DNA or UDG activity.
Collapse
Affiliation(s)
- Xiaolong Chen
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Yawen Wu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Gaihua Cao
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Xianfeng Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Zhong Ji
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
- Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, PR China
| | - Faliang Xu
- Treatment Center of Breast Diseases, Chongqing Cancer Institute and Hospital, Chongqing University, Chongqing 400030, PR China
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| |
Collapse
|
16
|
Škugor Rončević I, Krivić D, Buljac M, Vladislavić N, Buzuk M. Polyelectrolytes Assembly: A Powerful Tool for Electrochemical Sensing Application. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3211. [PMID: 32517055 PMCID: PMC7313698 DOI: 10.3390/s20113211] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 06/01/2020] [Accepted: 06/01/2020] [Indexed: 12/20/2022]
Abstract
The development of sensing coatings, as important sensor elements that integrate functionality, simplicity, chemical stability, and physical stability, has been shown to play a major role in electrochemical sensing system development trends. Simple and versatile assembling procedures and scalability make polyelectrolytes highly convenient for use in electrochemical sensing applications. Polyelectrolytes are mainly used in electrochemical sensor architectures for entrapping (incorporation, immobilization, etc.) various materials into sensing layers. These materials can often increase sensitivity, selectivity, and electronic communications with the electrode substrate, and they can mediate electron transfer between an analyte and transducer. Analytical performance can be significantly improved by the synergistic effect of materials (sensing material, transducer, and mediator) present in these composites. As most reported methods for the preparation of polyelectrolyte-based sensing layers are layer-by-layer and casting/coating methods, this review focuses on the use of the latter methods in the development of electrochemical sensors within the last decade. In contrast to many reviews related to electrochemical sensors that feature polyelectrolytes, this review is focused on architectures of sensing layers and the role of polyelectrolytes in the development of sensing systems. Additionally, the role of polyelectrolytes in the preparation and modification of various nanoparticles, nanoprobes, reporter probes, nanobeads, etc. that are used in electrochemical sensing systems is also reviewed.
Collapse
Affiliation(s)
- Ivana Škugor Rončević
- Department of General and Inorganic Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia; (I.Š.R.); (N.V.)
| | - Denis Krivić
- Division of Biophysics, Gottfried Schatz Research Center, Medical University of Graz, 8036 Graz, Austria;
| | - Maša Buljac
- Department of Environmental Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia;
| | - Nives Vladislavić
- Department of General and Inorganic Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia; (I.Š.R.); (N.V.)
| | - Marijo Buzuk
- Department of General and Inorganic Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia; (I.Š.R.); (N.V.)
| |
Collapse
|
17
|
Aliheidari N, Aliahmad N, Agarwal M, Dalir H. Electrospun Nanofibers for Label-Free Sensor Applications. SENSORS (BASEL, SWITZERLAND) 2019; 19:E3587. [PMID: 31426538 PMCID: PMC6720643 DOI: 10.3390/s19163587] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/12/2019] [Accepted: 08/14/2019] [Indexed: 12/13/2022]
Abstract
Electrospinning is a simple, low-cost and versatile method for fabricating submicron and nano size fibers. Due to their large surface area, high aspect ratio and porous structure, electrospun nanofibers can be employed in wide range of applications. Biomedical, environmental, protective clothing and sensors are just few. The latter has attracted a great deal of attention, because for biosensor application, nanofibers have several advantages over traditional sensors, including a high surface-to-volume ratio and ease of functionalization. This review provides a short overview of several electrospun nanofibers applications, with an emphasis on biosensor applications. With respect to this area, focus is placed on label-free sensors, pertaining to both recent advances and fundamental research. Here, label-free sensor properties of sensitivity, selectivity, and detection are critically evaluated. Current challenges in this area and prospective future work is also discussed.
Collapse
Affiliation(s)
- Nahal Aliheidari
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
- Integrated Nanosystems Development Institute (INDI), Indiana University-Purdue University Indianapolis, Indianapolis, IN 46202, USA
| | - Nojan Aliahmad
- Integrated Nanosystems Development Institute (INDI), Indiana University-Purdue University Indianapolis, Indianapolis, IN 46202, USA
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Mangilal Agarwal
- Integrated Nanosystems Development Institute (INDI), Indiana University-Purdue University Indianapolis, Indianapolis, IN 46202, USA.
- Purdue School of Engineering and Technology, Indiana University-Purdue University, Indianapolis, IN 46202, USA.
| | - Hamid Dalir
- Integrated Nanosystems Development Institute (INDI), Indiana University-Purdue University Indianapolis, Indianapolis, IN 46202, USA.
- Purdue School of Engineering and Technology, Indiana University-Purdue University, Indianapolis, IN 46202, USA.
| |
Collapse
|
18
|
Dakshayini B, Reddy KR, Mishra A, Shetti NP, Malode SJ, Basu S, Naveen S, Raghu AV. Role of conducting polymer and metal oxide-based hybrids for applications in ampereometric sensors and biosensors. Microchem J 2019. [DOI: 10.1016/j.microc.2019.02.061] [Citation(s) in RCA: 134] [Impact Index Per Article: 26.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
19
|
Fallahi A, Mandla S, Kerr-Phillip T, Seo J, Rodrigues RO, Jodat YA, Samanipour R, Hussain MA, Lee CK, Bae H, Khademhosseini A, Travas-Sejdic J, Shin SR. Flexible and Stretchable PEDOT-Embedded Hybrid Substrates for Bioengineering and Sensory Applications. CHEMNANOMAT : CHEMISTRY OF NANOMATERIALS FOR ENERGY, BIOLOGY AND MORE 2019; 5:729-737. [PMID: 33859923 PMCID: PMC8045745 DOI: 10.1002/cnma.201900146] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Indexed: 05/27/2023]
Abstract
Herein, we introduce a flexible, biocompatible, robust and conductive electrospun fiber mat as a substrate for flexible and stretchable electronic devices for various biomedical applications. To impart the electrospun fiber mats with electrical conductivity, poly(3,4-ethylenedioxythiophene) (PEDOT), a conductive polymer, was interpenetrated into nitrile butadiene rubber (NBR) and poly(ethylene glycol) dimethacrylate (PEGDM) crosslinked electrospun fiber mats. The mats were fabricated with tunable fiber orientation, random and aligned, and displayed elastomeric mechanical properties and high conductivity. In addition, bending the mats caused a reversible change in their resistance. The cytotoxicity studies confirmed that the elastomeric and conductive electrospun fiber mats support cardiac cell growth, and thus are adaptable to a wide range of applications, including tissue engineering, implantable sensors and wearable bioelectronics.
Collapse
Affiliation(s)
- Afsoon Fallahi
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02139, USA, Office: (617) 768-8320,
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Serena Mandla
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02139, USA, Office: (617) 768-8320,
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- S. Mandla, Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Thomas Kerr-Phillip
- Dr. T. Kerr-Phillip, Prof. J. Travas-Sejdic, Polymer Electronics Research Centre (PERC), School of Chemical Sciences, The University of Auckland, 23 Symonds Street, Auckland, New Zealand
- Dr. T. Kerr-Phillip, Prof. J. Travas-Sejdic, The MacDiarmid Institute for Advanced Materials and Nanotechnology New Zealand
| | - Jungmok Seo
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02139, USA, Office: (617) 768-8320,
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Prof. J. Seo, Centre for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology, 14 Hwarang-ro, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Raquel O Rodrigues
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02139, USA, Office: (617) 768-8320,
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- R. O. Rodrigues, Laboratory of Separation and Reaction Engineering, Laboratory of Catalysis and Materials (LSRE-LCM), Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Yasamin A Jodat
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02139, USA, Office: (617) 768-8320,
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Y. A. Jodat, Department of Mechanical Engineering, Stevens Institute of Technology, New Jersey, USA
| | - Roya Samanipour
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02139, USA, Office: (617) 768-8320,
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Dr. R. Samanipour, School of Engineering, University of British Columbia, Okanagan, BC, Canada
| | - Mohammad Asif Hussain
- Prof. M. A. Hussain, Department of Electrical and Computer Engineering, Faculty of Engineering, King Abdulaziz University, P.O. Box 80204, Jeddah 21589, Saudi Arabia
| | - Chang Kee Lee
- Dr. C. K. Lee, Korea Packaging Center, Korea Institute of Industrial Technology, Bucheon, Republic of Korea
| | - Hojae Bae
- Prof. H. Bae, Prof. A. Khademhosseini, KU Convergence Science and Technology Institute, Department of Stem Cell and Regenerative Biotechnology, Konkuk University, Seoul, 05029, Republic of Korea
| | - Ali Khademhosseini
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02139, USA, Office: (617) 768-8320,
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Prof. H. Bae, Prof. A. Khademhosseini, KU Convergence Science and Technology Institute, Department of Stem Cell and Regenerative Biotechnology, Konkuk University, Seoul, 05029, Republic of Korea
- Prof. A. Khademhosseini, Department of Bioengineering, Department of Chemical and Biomolecular Engineering, Henry Samueli School of Engineering and Applied Sciences, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Prof. A. Khademhosseini, Department of Radiology, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Prof. A. Khademhosseini, California NanoSystems Institute (CNSI), University of California-Los Angeles, Los Angeles, CA 90095, USA
- Prof. A. Khademhosseini, Centre for Minimally Invasive Therapeutics (C-MIT), California NanoSystems Institute, University of California - Los Angeles, Los Angeles, CA 90095, USA
| | - Jadranka Travas-Sejdic
- Dr. T. Kerr-Phillip, Prof. J. Travas-Sejdic, Polymer Electronics Research Centre (PERC), School of Chemical Sciences, The University of Auckland, 23 Symonds Street, Auckland, New Zealand
- Dr. T. Kerr-Phillip, Prof. J. Travas-Sejdic, The MacDiarmid Institute for Advanced Materials and Nanotechnology New Zealand
| | - Su Ryon Shin
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02139, USA, Office: (617) 768-8320,
- Dr. A. Fallahi, S. Mandla, Prof. J. Seo, R. O. Rodrigues, Y. A. Jodat, Dr. R. Samanipour, Prof. A. Khademhosseini, Dr. S. R. Shin, Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
20
|
Hairpin probes based click polymerization for label-free electrochemical detection of human T-lymphotropic virus types II. Anal Chim Acta 2019; 1059:86-93. [DOI: 10.1016/j.aca.2019.01.027] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2018] [Revised: 01/05/2019] [Accepted: 01/14/2019] [Indexed: 11/24/2022]
|
21
|
Chan EWC, Baek P, Tan SM, Davidson SJ, Barker D, Travas-Sejdic J. Molecular "Building Block" and "Side Chain Engineering": Approach to Synthesis of Multifunctional and Soluble Poly(pyrrole phenylene)s. Macromol Rapid Commun 2018; 40:e1800749. [PMID: 30512205 DOI: 10.1002/marc.201800749] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 11/19/2018] [Indexed: 02/06/2023]
Abstract
Here, the synthesis of a novel poly(pyrrole phenylene) (PpyP) that is both modular in ways of functionalization and soluble in organic solvents is reported, and therefore solution processable. This is achieved through the functionalization of the side-chain substituents in pyrrole phenylene (PyP) repeating units. t Butyl acrylate brushes are first grafted through atom transfer radical polymerization from one type of PyP, followed by oxidative chemical co-polymerization of the grafted PyP with a PyP bearing different side chains-either an azide or a methoxy moiety, resulting in a soluble PpyP where solubility is not dopant-dependent. Successful post-polymerization modification through "click" chemistry and post-polymerization processing via electrospinning are also demonstrated. Additionally, performed computational calculations indicate planarity of the novel polyrrole phenylene monomers and ionisation potentials that favor α-α bond formation during their polymerization.
Collapse
Affiliation(s)
- Eddie Wai Chi Chan
- Polymer Electronics Research Centre, School of Chemical Sciences, The University of Auckland, 23 Symonds Street, Auckland, 1010, New Zealand
| | - Paul Baek
- Polymer Electronics Research Centre, School of Chemical Sciences, The University of Auckland, 23 Symonds Street, Auckland, 1010, New Zealand.,The MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington, 6140, New Zealand
| | - Shi Min Tan
- Polymer Electronics Research Centre, School of Chemical Sciences, The University of Auckland, 23 Symonds Street, Auckland, 1010, New Zealand
| | - Samuel J Davidson
- Polymer Electronics Research Centre, School of Chemical Sciences, The University of Auckland, 23 Symonds Street, Auckland, 1010, New Zealand
| | - David Barker
- Polymer Electronics Research Centre, School of Chemical Sciences, The University of Auckland, 23 Symonds Street, Auckland, 1010, New Zealand.,The MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington, 6140, New Zealand
| | - Jadranka Travas-Sejdic
- Polymer Electronics Research Centre, School of Chemical Sciences, The University of Auckland, 23 Symonds Street, Auckland, 1010, New Zealand.,The MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington, 6140, New Zealand
| |
Collapse
|
22
|
Baek P, Voorhaar L, Barker D, Travas-Sejdic J. Molecular Approach to Conjugated Polymers with Biomimetic Properties. Acc Chem Res 2018; 51:1581-1589. [PMID: 29897228 DOI: 10.1021/acs.accounts.7b00596] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
The field of bioelectronics involves the fascinating interplay between biology and human-made electronics. Applications such as tissue engineering, biosensing, drug delivery, and wearable electronics require biomimetic materials that can translate the physiological and chemical processes of biological systems, such as organs, tissues. and cells, into electrical signals and vice versa. However, the difference in the physical nature of soft biological elements and rigid electronic materials calls for new conductive or electroactive materials with added biomimetic properties that can bridge the gap. Soft electronics that utilize organic materials, such as conjugated polymers, can bring many important features to bioelectronics. Among the many advantages of conjugated polymers, the ability to modulate the biocompatibility, solubility, functionality, and mechanical properties through side chain engineering can alleviate the issues of mechanical mismatch and provide better interface between the electronics and biological elements. Additionally, conjugated polymers, being both ionically and electrically conductive through reversible doping processes provide means for direct sensing and stimulation of biological processes in cells, tissues, and organs. In this Account, we focus on our recent progress in molecular engineering of conjugated polymers with tunable biomimetic properties, such as biocompatibility, responsiveness, stretchability, self-healing, and adhesion. Our approach is general and versatile, which is based on functionalization of conjugated polymers with long side chains, commonly polymeric or biomolecules. Applications for such materials are wide-ranging, where we have demonstrated conductive, stimuli-responsive antifouling, and cell adhesive biointerfaces that can respond to external stimuli such as temperature, salt concentration, and redox reactions, the processes that in turn modify and reversibly switch the surface properties. Furthermore, utilizing the advantageous chemical, physical, mechanical and functional properties of the grafts, we progressed into grafting of the long side chains onto conjugated polymers in solution, with the vision of synthesizing solution-processable conjugated graft copolymers with biomimetic functionalities. Examples of the developed materials to date include rubbery and adhesive photoluminescent plastics, biomolecule-functionalized electrospun biosensors, thermally and dually responsive photoluminescent conjugated polymers, and tunable self-healing, adhesive, and stretchable strain sensors, advanced functional biocidal polymers, and filtration membranes. As outlined in these examples, the applications of these biomimetic, conjugated polymers are still in the development stage toward truly printable, organic bioelectronic devices. However, in this Account, we advocate that molecular engineering of conjugated polymers is an attractive approach to a versatile class of organic electronics with both ionic and electrical conductivity as well as mechanical properties required for next-generation bioelectronics.
Collapse
Affiliation(s)
- Paul Baek
- Polymer Electronics Research Centre, School of Chemical Sciences, University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - Lenny Voorhaar
- Polymer Electronics Research Centre, School of Chemical Sciences, University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| | - David Barker
- Polymer Electronics Research Centre, School of Chemical Sciences, University of Auckland, Auckland 1010, New Zealand
| | - Jadranka Travas-Sejdic
- Polymer Electronics Research Centre, School of Chemical Sciences, University of Auckland, Auckland 1010, New Zealand
- The MacDiarmid Institute for Advanced Materials and Nanotechnology, Wellington 6140, New Zealand
| |
Collapse
|
23
|
Zhu B, Travas-Sejdic J. PNA versus DNA in electrochemical gene sensing based on conducting polymers: study of charge and surface blocking effects on the sensor signal. Analyst 2018; 143:687-694. [PMID: 29297913 DOI: 10.1039/c7an01590a] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
In this communication, we present an in-depth study of DNA/DNA, DNA/PNA and PNA/PNA hybridisation on a conducting polymer-modified electrode, measured by means of electrochemical impedance spectroscopy (EIS). DNA or PNA nucleic base sequence probes (where DNA stands for deoxyribonucleic acid and PNA for peptide nucleic acid) were covalently attached onto the sensor surface. As PNA is a non-charged variant of DNA, we investigate the effects of the surface charge and surface blocking by the surface confined probe/target nucleic bases complexes onto the kinetics of redox reaction of Fe(CN)63-/4- couple occurring at the electrode/solution interface that provides electrochemical readout for hybridisation. A range of hybridisation detection experiments were performed, where the surface charge and surface charge density were varied, through varying the charged nature of the probe and the target (i.e. PNA or DNA) and the density of surface-bound PNA and DNA probes. To further the understanding of these effects on the measured electrochemical signal, kinetic studies of the hybridisation reactions were undertaken, and the equilibrium binding constants and binding rate constants for the hybridisation reactions were obtained. The study provides valuable insights to guide future designs of biosensors.
Collapse
Affiliation(s)
- Bicheng Zhu
- Polymer Electronics Research Centre, School of Chemical Sciences, University of Auckland, 23 Symonds Street, Auckland, New Zealand. and The MacDiarmid Institute for Advanced Materials and Nanotechnology, New Zealand
| | - Jadranka Travas-Sejdic
- Polymer Electronics Research Centre, School of Chemical Sciences, University of Auckland, 23 Symonds Street, Auckland, New Zealand. and The MacDiarmid Institute for Advanced Materials and Nanotechnology, New Zealand
| |
Collapse
|