1
|
Myndrul V, Tamashevski A, Lipińska W, Siuzdak K, Iatsunskyi I. Highly sensitive electrochemical multimodal immunosensor for cluster of differentiation 5 (CD5) detection in human blood serum for early stage cancer detection based on laser-processed Ti/Au electrodes. Talanta 2024; 279:126612. [PMID: 39084041 DOI: 10.1016/j.talanta.2024.126612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2024] [Revised: 07/21/2024] [Accepted: 07/23/2024] [Indexed: 08/02/2024]
Abstract
In the rapidly evolving field of medical diagnostics, biomarkers play a pivotal role, particularly in the early detection of cancer. Cluster of differentiation 5 (CD5), a cell surface glycoprotein found on T cells and B-1a lymphocytes, is instrumental in immune regulation and is associated with both autoimmune diseases and malignancies. Despite its significant diagnostic and therapeutic potential, CD5 detection has been limited by modern methods in the pg/ml range. This study presents a novel multimodal electrochemical immunosensor that employs laser-processed Ti/Au electrodes for the ultra-sensitive detection of CD5 in human blood serum. The "multimodal" approach combines different analytical techniques - differential pulse volctammetry (DPV) and electrochemical impedance spectroscopy (EIS) - to ensure comprehensive analysis, enhancing both the accuracy and reliability of the sensor. This novel sensor significantly outperforms existing commercial ELISA kits, achieving a limit of detection (LOD) of 1.1 ± 0.2 fg/mL with DPV and 3.9 ± 0.5 fg/mL with EIS in phosphate-buffered saline (PBS) and 6.6 ± 3.1 fg/mL and 15.6 ± 3.1 fg/mL in human serum (HS), respectively. These results highlight the immunosensor's potential for improving early-stage cancer diagnosis and broader medical applications.
Collapse
Affiliation(s)
- Valerii Myndrul
- Sensor Engineering Department, Faculty of Science and Engineering, Maastricht University, P.O. Box 616, 6200 MD, Maastricht, the Netherlands; NanoBioMedical Centre, Adam Mickiewicz University, 3, Wszechnicy Piastowskiej Str., 61-614, Poznan, Poland.
| | - Alexander Tamashevski
- NanoBioMedical Centre, Adam Mickiewicz University, 3, Wszechnicy Piastowskiej Str., 61-614, Poznan, Poland
| | - Wiktoria Lipińska
- Centre for Plasma and Laser Engineering, Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Fiszera 14 St., 80-231, Gdansk, Poland
| | - Katarzyna Siuzdak
- Centre for Plasma and Laser Engineering, Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Fiszera 14 St., 80-231, Gdansk, Poland
| | - Igor Iatsunskyi
- NanoBioMedical Centre, Adam Mickiewicz University, 3, Wszechnicy Piastowskiej Str., 61-614, Poznan, Poland.
| |
Collapse
|
2
|
López-Marzo A, Mas-Torrent M. Bioreceptors' immobilization by hydrogen bonding interactions and differential pulse voltammetry for completely label-free electrochemical biosensors. Mikrochim Acta 2024; 191:669. [PMID: 39400624 PMCID: PMC11473665 DOI: 10.1007/s00604-024-06738-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 09/21/2024] [Indexed: 10/15/2024]
Abstract
Label-free electrochemical biosensors show great potential for the development of point-of-care devices (POCDs) for environmental and clinical applications. These sensors operate with shorter analysis times and are more economic than the labelled ones. Here, four completely label-free biosensors without electron transfer mediators were developed for hepatitis B virus (HBV) detection. The approach consisted in (i) the modification of gold surfaces with cysteamine (CT) or cysteine (CS) linkers, (ii) the subsequent antibody (Ab) immobilization, either directly by hydrogen bonding (HB) interactions or by covalent bonds (CB) using additional reagents, and (iii) measuring the biosensor response by electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). The electrode surfaces at each stage of the modification process were characterised by X-ray photo-electron spectroscopy (XPS) and atomic force microscopy (AFM). The combination of Ab immobilization by HB with the DPV analysis displayed improved repeatability, lower interference to serum matrix and similar limits of detection and quantification than the traditional biosensors that immobilize the Ab via CB and use EIS as readout technique. The Ab immobilization by HB is shown as a simple, efficient and low-cost alternative to CB ones, while DPV was faster and showed better performance than EIS. The CT-HB biosensor displayed the lowest limits of detection and quantification of 0.14 and 0.46 ng/mL, respectively, a 0.46-12.5 ng/mL linear analytical range, and 100% of recovery for 1/10 human serum media during HBV surface antigen detection by DPV. Even, it preserved the initial sensing capability after 7 days of its fabrication.
Collapse
Affiliation(s)
- Adaris López-Marzo
- Institut de Ciència de Materials de Barcelona, ICMAB-CSIC, Campus UAB, 08193, Bellaterra, Spain
| | - Marta Mas-Torrent
- Institut de Ciència de Materials de Barcelona, ICMAB-CSIC, Campus UAB, 08193, Bellaterra, Spain.
| |
Collapse
|
3
|
Lv Y, Zhou Y, Dong H, Xu M, Zhang J, Yan M. Ultrasensitive electrochemical detection of amyloid-beta oligomers using double amplification strategy by MXene substrate and covalent organic framework-based probe. Talanta 2024; 266:125134. [PMID: 37659228 DOI: 10.1016/j.talanta.2023.125134] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 07/02/2023] [Accepted: 08/26/2023] [Indexed: 09/04/2023]
Abstract
Most of the existing electrochemical systems failed to achieve satisfactory results in early diagnosis of Alzheimer's disease (AD) owing to a deficiency of effective signal transduction. A new method for the electrochemical detection of AD biomarkers (amyloid-beta oligomers, Aβ1-42 oligomers) was developed based on a double amplification strategy. Titanium carbide (Ti3C2) MXene decorated by gold nanoparticles (Au-MXene) as the electrode substrate not only gave rise to the electrochemical response due to its paradoxical surface area and conspicuous charge mobility, but also provided vast numbers of binding sites for aptamers (Apt) of Aβ1-42 oligomers. Meanwhile, AuNPs were incorporated into covalent organic frameworks (COFs), which were further modified by Apt and electron mediator (toluidine blue, TB). The Apt/TB-Au@COFs composite was utilized as a label because of their improvement of the electron-hole separation efficiency and optimization of the charge-carrier utilization. The proposed electrochemical assay established highly efficient platform for the detection of Aβ1-42 oligomers with a linear range from 0.01 pg mL-1 to 180 pg mL-1 and an ultralow detection limit of 4.27 fg mL-1 (S/N = 3). This biosensing platform had potential applications in molecular diagnostics of AD serum samples.
Collapse
Affiliation(s)
- Yubing Lv
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, Shandong, China
| | - Yanli Zhou
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, Henan, China.
| | - Hui Dong
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, Henan, China
| | - Maotian Xu
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, Henan, China
| | - Jing Zhang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, Shandong, China.
| | - Mei Yan
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, Shandong, China.
| |
Collapse
|
4
|
Le PG, Choi SH, Cho S. Alzheimer's Disease Biomarker Detection Using Field Effect Transistor-Based Biosensor. BIOSENSORS 2023; 13:987. [PMID: 37998162 PMCID: PMC10669709 DOI: 10.3390/bios13110987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 11/14/2023] [Accepted: 11/16/2023] [Indexed: 11/25/2023]
Abstract
Alzheimer's disease (AD) is closely related to neurodegeneration, leading to dementia and cognitive impairment, especially in people aged > 65 years old. The detection of biomarkers plays a pivotal role in the diagnosis and treatment of AD, particularly at the onset stage. Field-effect transistor (FET)-based sensors are emerging devices that have drawn considerable attention due to their crucial ability to recognize various biomarkers at ultra-low concentrations. Thus, FET is broadly manipulated for AD biomarker detection. In this review, an overview of typical FET features and their operational mechanisms is described in detail. In addition, a summary of AD biomarker detection and the applicability of FET biosensors in this research field are outlined and discussed. Furthermore, the trends and future prospects of FET devices in AD diagnostic applications are also discussed.
Collapse
Affiliation(s)
- Phan Gia Le
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Republic of Korea
| | - Seong Hye Choi
- Department of Neurology, College of Medicine, Inha University, Incheon 22332, Republic of Korea
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Republic of Korea
- Gachon Advanced Institute for Health Sciences and Technology (GAIHST), Gachon University, Incheon 21999, Republic of Korea
| |
Collapse
|
5
|
Le PG, Le HTN, Kim HE, Cho S. SAM-Support-Based Electrochemical Sensor for Aβ Biomarker Detection of Alzheimer's Disease. BIOSENSORS 2023; 13:809. [PMID: 37622895 PMCID: PMC10452698 DOI: 10.3390/bios13080809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 08/01/2023] [Accepted: 08/09/2023] [Indexed: 08/26/2023]
Abstract
Alzheimer's disease has taken the spotlight as a neurodegenerative disease which has caused crucial issues to both society and the economy. Specifically, aging populations in developed countries face an increasingly serious problem due to the increasing budget for patient care and an inadequate labor force, and therefore a solution is urgently needed. Recently, diverse techniques for the detection of Alzheimer's biomarkers have been researched and developed to support early diagnosis and treatment. Among them, electrochemical biosensors and electrode modification proved their effectiveness in the detection of the Aβ biomarker at appropriately low concentrations for practice and point-of-care application. This review discusses the production and detection ability of amyloid beta, an Alzheimer's biomarker, by electrochemical biosensors with SAM support for antibody conjugation. In addition, future perspectives on SAM for the improvement of electrochemical biosensors are also proposed and discussed.
Collapse
Affiliation(s)
- Phan Gia Le
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Republic of Korea; (P.G.L.); (H.T.N.L.)
| | - Hien T. Ngoc Le
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Republic of Korea; (P.G.L.); (H.T.N.L.)
| | - Hee-Eun Kim
- Department of Dental Hygiene, Gachon University, Incheon 21936, Republic of Korea;
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Republic of Korea; (P.G.L.); (H.T.N.L.)
- Department of Health Sciences and Technology (GAIHST), Gachon University, Incheon 21999, Republic of Korea
| |
Collapse
|
6
|
Sharma A, Angnes L, Sattarahmady N, Negahdary M, Heli H. Electrochemical Immunosensors Developed for Amyloid-Beta and Tau Proteins, Leading Biomarkers of Alzheimer's Disease. BIOSENSORS 2023; 13:742. [PMID: 37504140 PMCID: PMC10377038 DOI: 10.3390/bios13070742] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 06/27/2023] [Accepted: 07/14/2023] [Indexed: 07/29/2023]
Abstract
Alzheimer's disease (AD) is the most common neurological disease and a serious cause of dementia, which constitutes a threat to human health. The clinical evidence has found that extracellular amyloid-beta peptides (Aβ), phosphorylated tau (p-tau), and intracellular tau proteins, which are derived from the amyloid precursor protein (APP), are the leading biomarkers for accurate and early diagnosis of AD due to their central role in disease pathology, their correlation with disease progression, their diagnostic value, and their implications for therapeutic interventions. Their detection and monitoring contribute significantly to understanding AD and advancing clinical care. Available diagnostic techniques, including magnetic resonance imaging (MRI) and positron emission tomography (PET), are mainly used to validate AD diagnosis. However, these methods are expensive, yield results that are difficult to interpret, and have common side effects such as headaches, nausea, and vomiting. Therefore, researchers have focused on developing cost-effective, portable, and point-of-care alternative diagnostic devices to detect specific biomarkers in cerebrospinal fluid (CSF) and other biofluids. In this review, we summarized the recent progress in developing electrochemical immunosensors for detecting AD biomarkers (Aβ and p-tau protein) and their subtypes (AβO, Aβ(1-40), Aβ(1-42), t-tau, cleaved-tau (c-tau), p-tau181, p-tau231, p-tau381, and p-tau441). We also evaluated the key characteristics and electrochemical performance of developed immunosensing platforms, including signal interfaces, nanomaterials or other signal amplifiers, biofunctionalization methods, and even primary electrochemical sensing performances (i.e., sensitivity, linear detection range, the limit of detection (LOD), and clinical application).
Collapse
Affiliation(s)
- Abhinav Sharma
- Solar Center, Physical Sciences and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia
| | - Lúcio Angnes
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo 05508-000, Brazil
| | - Naghmeh Sattarahmady
- Department of Medical Physics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Masoud Negahdary
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo 05508-000, Brazil
| | - Hossein Heli
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
7
|
Montero-Arevalo B, Seufert BI, Hossain MS, Bernardin E, Takshi A, Saddow SE, Schettini N. SiC Electrochemical Sensor Validation for Alzheimer Aβ 42 Antigen Detection. MICROMACHINES 2023; 14:1262. [PMID: 37374847 DOI: 10.3390/mi14061262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/07/2023] [Accepted: 06/13/2023] [Indexed: 06/29/2023]
Abstract
Alzheimer's disease (AD) is a neurodegenerative disease with only late-stage detection; thus, diagnosis is made when it is no longer possible to treat the disease, only its symptoms. Consequently, this often leads to caregivers who are the patient's relatives, which adversely impacts the workforce along with severely diminishing the quality of life for all involved. It is, therefore, highly desirable to develop a fast, effective and reliable sensor to enable early-stage detection in an attempt to reverse disease progression. This research validates the detection of amyloid-beta 42 (Aβ42) using a Silicon Carbide (SiC) electrode, a fact that is unprecedented in the literature. Aβ42 is considered a reliable biomarker for AD detection, as reported in previous studies. To validate the detection with a SiC-based electrochemical sensor, a gold (Au) electrode-based electrochemical sensor was used as a control. The same cleaning, functionalization and Aβ1-28 antibody immobilization steps were used on both electrodes. Sensor validation was carried out by means of Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) aiming to detect an 0.5 µg·mL-1 Aβ42 concentration in 0.1 M buffer solution as a proof of concept. A repeatable peak directly related to the presence of Aβ42 was observed, indicating that a fast SiC-based electrochemical sensor was constructed and may prove to be a useful approach for the early detection of AD.
Collapse
Affiliation(s)
- Brayan Montero-Arevalo
- Department of Electrical and Electronic Engineering, Universidad del Norte, Barranquilla 081007, Colombia
| | - Bianca I Seufert
- Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA
| | - Mohammad S Hossain
- Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA
| | - Evans Bernardin
- Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA
| | - Arash Takshi
- Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA
| | - Stephen E Saddow
- Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA
| | - Norelli Schettini
- Department of Electrical and Electronic Engineering, Universidad del Norte, Barranquilla 081007, Colombia
| |
Collapse
|
8
|
Liang Q, Huang Y, Wang M, Kuang D, Yang J, Yi Y, Shi H, Li J, Yang J, Li G. An electrochemical biosensor for SARS-CoV-2 detection via its papain-like cysteine protease and the protease inhibitor screening. CHEMICAL ENGINEERING JOURNAL (LAUSANNE, SWITZERLAND : 1996) 2023; 452:139646. [PMID: 36249721 PMCID: PMC9549716 DOI: 10.1016/j.cej.2022.139646] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 09/21/2022] [Accepted: 10/04/2022] [Indexed: 05/04/2023]
Abstract
The persistent coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is still infecting hundreds of thousands of people every day. Enriching the kits for SARS-CoV-2 detection and developing the drugs for patient treatments are still urgently needed for combating the spreading virus, especially after the emergence of various mutants. Herein, an electrochemical biosensor has been fabricated in this work for the detection of SARS-CoV-2 via its papain-like cysteine protease (PLpro) and the screening of protease inhibitor against SARS-CoV-2 by using our designed chimeric peptide-DNA (pDNA) nanoprobes. Utilizing this biosensor, the sensitive and specific detection of SARS-CoV-2 PLpro can be conducted in complex real environments including blood and saliva. Five positive and five negative patient throat swab samples have also been tested to verify the practical application capability of the biosensor. Moreover, we have obtained a detection limit of 27.18 fM and a linear detection range from 1 pg mL-1 to 10 μg mL-1 (I = 1.63 + 4.44 lgC). Meanwhile, rapid inhibitor screening against SARS-CoV-2 PLpro can be also obtained. Therefore, this electrochemical biosensor has the great potential for COVID-19 combating and drug development.
Collapse
Affiliation(s)
- Qizhi Liang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Life Sciences, Nanjing University, Nanjing 210023, PR China
| | - Yue Huang
- Department of Food Science and Engineering, College of Light Industry and Food Engineering, Nanjing Forestry University, Nanjing 210037, PR China
| | - Minghui Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Life Sciences, Nanjing University, Nanjing 210023, PR China
| | - Deqi Kuang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Life Sciences, Nanjing University, Nanjing 210023, PR China
| | - Jiahua Yang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Life Sciences, Nanjing University, Nanjing 210023, PR China
| | - Yongxiang Yi
- Department of Clinical Laboratory, The Second Hospital of Nanjing, Nanjing University of Chinese Medicine, Nanjing 210003, PR China
| | - Hai Shi
- Department of Oncology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, PR China
| | - Jinlong Li
- Department of Clinical Laboratory, The Second Hospital of Nanjing, Nanjing University of Chinese Medicine, Nanjing 210003, PR China
| | - Jie Yang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Life Sciences, Nanjing University, Nanjing 210023, PR China
| | - Genxi Li
- State Key Laboratory of Analytical Chemistry for Life Science, School of Life Sciences, Nanjing University, Nanjing 210023, PR China
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China
| |
Collapse
|
9
|
Lu X, Hou X, Tang H, Yi X, Wang J. A High-Quality CdSe/CdS/ZnS Quantum-Dot-Based FRET Aptasensor for the Simultaneous Detection of Two Different Alzheimer's Disease Core Biomarkers. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:nano12224031. [PMID: 36432316 PMCID: PMC9697525 DOI: 10.3390/nano12224031] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 11/06/2022] [Accepted: 11/12/2022] [Indexed: 05/31/2023]
Abstract
The simultaneous detection of two different biomarkers for the point-of-care diagnosis of major diseases, such as Alzheimer’s disease (AD), is greatly challenging. Due to the outstanding photoluminescence (PL) properties of quantum dots (QDs), a high-quality CdSe/CdS/ZnS QD-based fluorescence resonance energy transfer (FRET) aptasensor for simultaneously monitoring the amyloid-β oligomers (AβO) and tau protein was proposed. By engineering the interior inorganic structure and inorganic−organic interface, water-soluble dual-color CdSe/CdS/ZnS QDs with a near-unity PL quantum yield (>90%) and mono-exponential PL decay dynamics were generated. The π−π stacking and hydrogen bond interaction between the aptamer-functionalized dual-color QDs and gold nanorods@polydopamine (Au NRs@PDA) nanoparticles resulted in significant fluorescence quenching of the QDs through FRET. Upon the incorporation of the AβO and tau protein, the fluorescence recovery of the QDs-DNA/Au NRs@PDA assembly was attained, providing the possibility of simultaneously assaying the two types of AD core biomarkers. The lower detection limits of 50 pM for AβO and 20 pM for the tau protein could be ascribed to the distinguishable and robust fluorescence of QDs and broad spectral absorption of Au NRs@PDA. The sensing strategy serves as a viable platform for the simultaneously monitoring of the core biomarkers for AD and other major diseases.
Collapse
Affiliation(s)
- Xingchang Lu
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China
| | - Xiaoqi Hou
- School of Chemistry and Material Science, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, 1 Sub-lane Xiangshan, Hangzhou 310024, China
- Key Laboratory of Intelligent Sensing Materials and Chip Integration Technology of Zhejiang Province, Hangzhou Innovation Institute, Beihang University, Hangzhou 310052, China
| | - Hailin Tang
- SunYat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou 510060, China
| | - Xinyao Yi
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China
| | - Jianxiu Wang
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China
| |
Collapse
|
10
|
Surface-Enhanced Carboxyphenyl Diazonium Functionalized Screen-Printed Carbon Electrode for the Screening of Tuberculosis in Sputum Samples. NANOMATERIALS 2022; 12:nano12152551. [PMID: 35893519 PMCID: PMC9329948 DOI: 10.3390/nano12152551] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 07/20/2022] [Accepted: 07/21/2022] [Indexed: 02/01/2023]
Abstract
Curbing tuberculosis (TB) requires a combination of good strategies, including a proper prevention measure, diagnosis, and treatment. This study proposes an improvised tuberculosis diagnosis based on an amperometry approach for the sensitive detection of MPT64 antigen in clinical samples. An MPT64 aptamer specific to the target antigen was covalently attached to the carboxyphenyl diazonium-functionalized carbon electrode via carbodiimide chemistry. The electrochemical detection assay was adapted from a sandwich assay format to trap the antigen between the immobilized aptamer and horseradish peroxidase (HRP) tagged polyclonal anti-MPT64 antibody. The amperometric current was measured from the catalytic reaction response between HRP, hydrogen peroxide, and hydroquinone, which is used as an electron mediator. From the analysis, the detection limit in the measurement buffer was 1.11 ng mL-1. Additionally, the developed aptasensor exhibited a linear relationship between the current signal and the MPT64 antigen-spiked serum concentration ranging from 10 to 150 ng mL-1 with a 1.38 ng mL-1 detection limit. Finally, an evaluation using the clinical sputum samples from both TB (+) and TB (-) individuals revealed a sensitivity and specificity of 88% and 100%, respectively. Based on the analysis, the developed aptasensor was found to be simple in its fabrication, sensitive, and allowed for the efficient detection and diagnosis of TB in sputum samples.
Collapse
|
11
|
Current trends in blood biomarker detection and imaging for Alzheimer’s disease. Biosens Bioelectron 2022; 210:114278. [DOI: 10.1016/j.bios.2022.114278] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 03/21/2022] [Accepted: 04/09/2022] [Indexed: 12/28/2022]
|
12
|
Le HTN, Phan LMT, Cho S. Removal of Thiol-SAM on a Gold Surface for Re-Use of an Interdigitated Chain-Shaped Electrode. MATERIALS 2022; 15:ma15062218. [PMID: 35329670 PMCID: PMC8950519 DOI: 10.3390/ma15062218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 03/07/2022] [Accepted: 03/15/2022] [Indexed: 11/16/2022]
Abstract
The self-assembled monolayer (SAM) is the most common organic assembly utilized for the formation of the monolayers of alkane-thiolates on gold electrode, resulting in a wide range of applications for the modified SAM on gold in various research areas. This study examined the desorption of a SAM that was developed on the gold surface of an interdigitated chain-shaped electrode (the ICE, a unique electrode design, was fabricated by our group) with the goal of determining the most efficient strategy of SAM removal for the ICE to be re-used. A simple and proficient solution-based cleaning procedure was applied for the removal of a SAM on the gold surface of the ICE by using a sodium borohydride solution within short-term treatment, resulting in efficiency for the recovery of the originally electrochemical characteristic of ICE of 90.3%. The re-use of ICE after the removal process was confirmed by the successful re-deposition of a SAM onto the electrode surface, resulting in the high efficiency percentage of 90.1% for the reusability of ICE with the SAM modification. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used as tools to investigate the changes in the electrode interface at each stage of the SAM removal and the electrode recycling. X-ray photoelectron spectroscopy and Fourier-transform infrared spectroscopy were employed, being powerful spectrum techniques, for the characterization of the bonding structure and chemical state of the bare ICE and the modified ICE at each treatment step. Based on the comprehensive discussion of analytical chemistry from the obtained EIS and CV data in this study, we confirmed and proved the effectiveness of this promising method for the removal of a SAM from the ICE and the re-use of ICE in the field of material deposition, with the aims of saving money, improving experimental handling, and protecting the environment.
Collapse
Affiliation(s)
- Hien T. Ngoc Le
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Korea;
| | - Le Minh Tu Phan
- School of Medicine and Pharmacy, The University of Danang, Danang 550000, Vietnam;
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si 13120, Korea;
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea
- Correspondence: ; Tel.: +82-(31)-750-5321
| |
Collapse
|
13
|
Wang BY, Gu BC, Wang GJ, Yang YH, Wu CC. Detection of Amyloid-β(1–42) Aggregation With a Nanostructured Electrochemical Sandwich Immunoassay Biosensor. Front Bioeng Biotechnol 2022; 10:853947. [PMID: 35372290 PMCID: PMC8965719 DOI: 10.3389/fbioe.2022.853947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 02/25/2022] [Indexed: 11/30/2022] Open
Abstract
Amyloid-β(1–42) [Aβ(1–42)] oligomer accumulations are associated with physiologic alterations in the brains of individuals with Alzheimer’s disease. In this study, we demonstrate that a nanostructured gold electrode with deposited gold nanoparticles, induced via electrochemical impedance spectroscopy (EIS), may be used as an Aβ(1–42) conformation biosensor for the detection of Alzheimer’s disease. Monoclonal antibodies (12F4) were immobilized on self-assembled monolayers of the electrochemical sandwich immunoassay biosensor to capture Aβ(1–42) monomers and oligomers. Western blot and fluorescence microscopy analyses were performed to confirm the presence of Aβ(1–42) monomers and oligomers. EIS analysis with an equivalent circuit model was used to determine the concentrations of different Aβ(1–42) conformations in this study. We identified conformations of Aβ(1–42) monomers and Aβ(1–42) oligomers using probe antibodies (12F4) by employing EIS. RAβ(1−42) indicates the sum resistance of impedance measured during Aβ(1–42) immobilization. ΔR12F4 refers to the concentration of probe antibody (12F4) binding with Aβ(1–42). The concentration of Aβ(1–42) oligomer was defined as the percentage of Aβ(1–42) aggregation R12F4/RAβ(1−42). The experimental results show that the biosensor has high selectivity to differentiate Aβ(1–40) and Aβ(1–42) monomers and Aβ(1–42) oligomers and that it can detect Aβ(1–42) oligomer accurately. The linear detection range for Aβ(1–42) oligomers was between 10 pg/ml and 100 ng/ml. The limit of detection was estimated to be 113 fg/ml.
Collapse
Affiliation(s)
- Bing-Yu Wang
- Department of Mechanical Engineering, National Chung Hsing University, Taichung, Taiwan
| | - Bien-Chen Gu
- Department of Mechanical Engineering, National Chung Hsing University, Taichung, Taiwan
| | - Gou-Jen Wang
- Department of Mechanical Engineering, National Chung Hsing University, Taichung, Taiwan
- Graduate Institute of Biomedical Engineering, National Chung Hsing University, Taichung, Taiwan
| | - Yuan-Han Yang
- Department of and Master's Program in Neurology, Faculty of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Neurology, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Neurology, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chia-Che Wu
- Department of Mechanical Engineering, National Chung Hsing University, Taichung, Taiwan
- Innovation and Development Center of Sustainable Agriculture (IDCSA), National Chung Hsing University, Taichung, Taiwan
- Smart Sustainable New Agriculture Research Center (SMARTer), Taichung, Taiwan
| |
Collapse
|
14
|
Le HTN, Kim D, Phan LMT, Cho S. Ultrasensitive capacitance sensor to detect amyloid-beta 1-40 in human serum using supramolecular recognition of β-CD/RGO/ITO micro-disk electrode. Talanta 2022; 237:122907. [PMID: 34736644 DOI: 10.1016/j.talanta.2021.122907] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 08/11/2021] [Accepted: 09/25/2021] [Indexed: 02/07/2023]
Abstract
In this paper, we developed a new ultrasensitive capacitance sensor for detection of amyloid beta 1-40 (aβ40) protein (one of Alzheimer's disease core biomarkers) in human serum based on the high supramolecular recognition of the β-cyclodextrin/reduced graphene oxide (β-CD/RGO) nanohybrid toward the anti-aβ40 antibody molecule. The sensor was established by immobilizing specific anti-aβ40 antibody onto the β-CD/RGO nanohybrid functionalized on indium tin oxide micro-disk electrode (anti-aβ40/β-CD/RGO/ITO). Detection of aβ40 in the human serum (HS) using the sensor anti-aβ40/β-CD/RGO/ITO is carried out by capacitance measurement without a redox probe to prevent protein denaturation, serving as a convenient strategy for point-of-care diagnosis. In comparison with other studies, the sensor shows a very low limit of detection of 0.69 fg mL-1 in HS, demonstrating its ability for the ultrasensitive detection of aβ40. Using this sensor, the dissociation constant KD of the binding interaction between anti-aβ40 and aβ40 in HS is found to be 2.9 × 10-7 nM, indicating the high binding affinity of antibody-antigen and the suitability of the anti-aβ40/β-CD/RGO/ITO sensor for aβ40 protein detection. The good selectivity of the anti-aβ40/β-CD/RGO/ITO sensor in the presence of differential analytes was also performed in this paper.
Collapse
Affiliation(s)
- Hien T Ngoc Le
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Daesoo Kim
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Le Minh Tu Phan
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do, 13120, South Korea; School of Medicine and Pharmacy, The University of Danang, Danang, 550000, Viet Nam.
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do, 13120, South Korea; Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon, 21999, South Korea.
| |
Collapse
|
15
|
Zhang L, Du X, Su Y, Niu S, Li Y, Liang X, Luo H. Quantitative assessment of AD markers using naked eyes: point-of-care testing with paper-based lateral flow immunoassay. J Nanobiotechnology 2021; 19:366. [PMID: 34789291 PMCID: PMC8597216 DOI: 10.1186/s12951-021-01111-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 11/02/2021] [Indexed: 01/01/2023] Open
Abstract
Aβ42 is one of the most extensively studied blood and Cerebrospinal fluid (CSF) biomarkers for the diagnosis of symptomatic and prodromal Alzheimer's disease (AD). Because of the heterogeneity and transient nature of Aβ42 oligomers (Aβ42Os), the development of technologies for dynamically detecting changes in the blood or CSF levels of Aβ42 monomers (Aβ42Ms) and Aβ42Os is essential for the accurate diagnosis of AD. The currently commonly used Aβ42 ELISA test kits usually mis-detected the elevated Aβ42Os, leading to incomplete analysis and underestimation of soluble Aβ42, resulting in a comprised performance in AD diagnosis. Herein, we developed a dual-target lateral flow immunoassay (dLFI) using anti-Aβ42 monoclonal antibodies 1F12 and 2C6 for the rapid and point-of-care detection of Aβ42Ms and Aβ42Os in blood samples within 30 min for AD diagnosis. By naked eye observation, the visual detection limit of Aβ42Ms or/and Aβ42Os in dLFI was 154 pg/mL. The test results for dLFI were similar to those observed in the enzyme-linked immunosorbent assay (ELISA). Therefore, this paper-based dLFI provides a practical and rapid method for the on-site detection of two biomarkers in blood or CSF samples without the need for additional expertise or equipment.
Collapse
Affiliation(s)
- Liding Zhang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, China
- MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, China
| | - Xuewei Du
- Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan, China
| | - Ying Su
- Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - Shiqi Niu
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, China
- MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, China
| | - Yanqing Li
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, China
- MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, China
| | - Xiaohan Liang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, China
- MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, China
| | - Haiming Luo
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, China.
- MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, China.
- , Wuhan, China.
| |
Collapse
|
16
|
Ding M, Shu Q, Zhang N, Yan C, Niu H, Li X, Guan P, Hu X. Electrochemical Immunosensor for the Sensitive Detection of Alzheimer's Biomarker Amyloid‐β (1–42) Using the Heme‐amyloid‐β (1–42) Complex as the Signal Source. ELECTROANAL 2021. [DOI: 10.1002/elan.202100392] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Minling Ding
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an 710072 P. R. China
| | - Qi Shu
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an 710072 P. R. China
| | - Nan Zhang
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an 710072 P. R. China
| | - Chaoren Yan
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an 710072 P. R. China
| | - Huizhe Niu
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an 710072 P. R. China
| | - Xiaoqian Li
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an 710072 P. R. China
| | - Ping Guan
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an 710072 P. R. China
| | - Xiaoling Hu
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an 710072 P. R. China
| |
Collapse
|
17
|
Fan Q, Gao Y, Mazur F, Chandrawati R. Nanoparticle-based colorimetric sensors to detect neurodegenerative disease biomarkers. Biomater Sci 2021; 9:6983-7007. [PMID: 34528639 DOI: 10.1039/d1bm01226f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Neurodegenerative disorders (NDDs) are progressive, incurable health conditions that primarily affect brain cells, and result in loss of brain mass and impaired function. Current sensing technologies for NDD detection are limited by high cost, long sample preparation, and/or require skilled personnel. To overcome these limitations, optical sensors, specifically colorimetric sensors, have garnered increasing attention towards the development of a cost-effective, simple, and rapid alternative approach. In this review, we evaluate colorimetric sensing strategies of NDD biomarkers (e.g. proteins, neurotransmitters, bio-thiols, and sulfide), address the limitations and challenges of optical sensor technologies, and provide our outlook on the future of this field.
Collapse
Affiliation(s)
- Qingqing Fan
- School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia.
| | - Yuan Gao
- School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia.
| | - Federico Mazur
- School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia.
| | - Rona Chandrawati
- School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia.
| |
Collapse
|
18
|
Abbasi HY, Tehrani Z, Devadoss A, Ali MM, Moradi-Bachiller S, Albani D, Guy OJ. Graphene based electrochemical immunosensor for the ultra-sensitive label free detection of Alzheimer's beta amyloid peptides Aβ(1-42). NANOSCALE ADVANCES 2021; 3:2295-2304. [PMID: 36133757 PMCID: PMC9419744 DOI: 10.1039/d0na00801j] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 02/17/2021] [Indexed: 05/11/2023]
Abstract
An immunosensor capable of high sensitivity detection of beta-amyloid peptides, shown to be a reliable biomarker for Alzheimer's disease, has been developed using screen printed graphene electrodes (SPGEs) modified with ultra-thin layers of polymerised 1,5-diaminonaphthalene (pDAN). Electropolymerization of 1,5-diaminonaphthalene (DAN) was performed to coat the graphene screen printed electrodes in a continuous polymer layer with controlled thickness. The surface characteristics of pristine graphene and polymer modified graphene electrodes were examined using Raman and X-ray photoelectron spectroscopy. The effects of polymer thickness on the electron transfer rates were investigated. An immunosensor for selective detection of beta amyloid peptides Aβ(1-42) was developed via biofunctionalization of the pDAN modified SPGE with the anti-beta amyloid antibody used as the peptide bioreceptor. The immunosensor has been used for specific detection of Aβ(1-42) with a linear range of 1 pg mL-1 to 1000 pg mL-1 and showed 1.4 pg mL-1 and 4.25 pg mL-1 detection and quantification limit, respectively. The biosensor was further validated for the analysis of spiked human plasma. The immunosensor enables rapid, accurate, precise, reproducible and highly sensitive detection of Aβ(1-42) using a low-cost SPGE platform, which opens the possibilities for diagnostic ex vivo applications and research-based real time studies.
Collapse
Affiliation(s)
- Hina Y Abbasi
- Centre for NanoHealth, College of Engineering, Swansea University Swansea SA2 8PP UK +44 (0) 1792 606475 +44 (0) 1792 513181
- Department of Chemistry, College of Science, Swansea University Swansea SA2 8PP UK
| | - Zari Tehrani
- Centre for NanoHealth, College of Engineering, Swansea University Swansea SA2 8PP UK +44 (0) 1792 606475 +44 (0) 1792 513181
- Department of Chemistry, College of Science, Swansea University Swansea SA2 8PP UK
| | - Anitha Devadoss
- Centre for NanoHealth, College of Engineering, Swansea University Swansea SA2 8PP UK +44 (0) 1792 606475 +44 (0) 1792 513181
- Department of Chemistry, College of Science, Swansea University Swansea SA2 8PP UK
| | - Muhammad Munem Ali
- Centre for NanoHealth, College of Engineering, Swansea University Swansea SA2 8PP UK +44 (0) 1792 606475 +44 (0) 1792 513181
| | - Soraya Moradi-Bachiller
- Department of Neuroscience, Istituto di Ricerche Farmacologiche Mario Negri IRCCS Via La Masa 19 20156 Milan Italy
| | - Diego Albani
- Department of Neuroscience, Istituto di Ricerche Farmacologiche Mario Negri IRCCS Via La Masa 19 20156 Milan Italy
| | - Owen J Guy
- Centre for NanoHealth, College of Engineering, Swansea University Swansea SA2 8PP UK +44 (0) 1792 606475 +44 (0) 1792 513181
- Department of Chemistry, College of Science, Swansea University Swansea SA2 8PP UK
| |
Collapse
|
19
|
Phan LMT, Hoang TX, Vo TAT, Pham HL, Le HTN, Chinnadayyala SR, Kim JY, Lee SM, Cho WW, Kim YH, Choi SH, Cho S. Nanomaterial-based Optical and Electrochemical Biosensors for Amyloid beta and Tau: Potential for early diagnosis of Alzheimer's Disease. Expert Rev Mol Diagn 2021; 21:175-193. [PMID: 33560154 DOI: 10.1080/14737159.2021.1887732] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
INTRODUCTION Alzheimer's disease (AD), a heterogeneous pathological process representing the most common causes of dementia worldwide, has required early and accurate diagnostic tools. Neuropathological hallmarks of AD involve the aberrant accumulation of Amyloid beta (Aβ) into Amyloid plaques and hyperphosphorylated Tau into neurofibrillary tangles, occurring long before the onset of brain dysfunction.Areas covered:Considering the significance of Aβ and Tau in AD pathogenesis, these proteins have been adopted as core biomarkers of AD, and their quantification has provided precise diagnostic information to develop next-generation AD therapeutic approaches. However, conventional diagnostic methods may not suffice to achieve clinical criteria that are acceptable for proper diagnosis and treatment. The advantages of nanomaterial-based biosensors including facile miniaturization, mass fabrication, ultra-sensitivity, make them useful to be promising tools to measure Aβ and Tau simultaneously for accurate validation of low-abundance yet potentially informative biomarkers of AD.. EXPERT OPINION The study has identified the potential application of advanced biosensors as standardized clinical diagnostic tools for AD, evolving the way for new and efficient AD control with minimum economic and social burden. After clinical trial, nanobiosensors for measuring Aβ and Tau simultaneously possess innovative diagnosis of AD to provide significant contributions to primary Alzheimer's care intervention.
Collapse
Affiliation(s)
- Le Minh Tu Phan
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea.,School of Medicine and Pharmacy, The University of Danang, Danang, Vietnam
| | - Thi Xoan Hoang
- Department of Life Science, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Thuy Anh Thu Vo
- Department of Life Science, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Hoang Lan Pham
- Department of Life Science, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Hien T Ngoc Le
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | | | - Jae Young Kim
- Department of Life Science, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | | | - Won Woo Cho
- Cantis Inc., Ansan-si, Gyeonggi-do, Republic of Korea
| | - Young Hyo Kim
- Department of Otorhinolaryngology-Head and Neck Surgery, School of Medicine, Inha University, Incheon, Republic of Korea
| | - Seong Hye Choi
- Department of Neurology, School of Medicine, Inha University, Incheon, Republic of Korea
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea.,Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon, Republic of Korea
| |
Collapse
|
20
|
Zhang J, Zhang X, Gao Y, Yan J, Song W. Integrating CuO/g-C3N4 p-n heterojunctioned photocathode with MoS2 QDs@Cu NWs multifunctional signal amplifier for ultrasensitive detection of AβO. Biosens Bioelectron 2021; 176:112945. [DOI: 10.1016/j.bios.2020.112945] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 12/04/2020] [Accepted: 12/27/2020] [Indexed: 01/03/2023]
|
21
|
Le HTN, Cho S. Deciphering the Disaggregation Mechanism of Amyloid Beta Aggregate by 4-(2-Hydroxyethyl)-1-Piperazinepropanesulfonic Acid Using Electrochemical Impedance Spectroscopy. SENSORS 2021; 21:s21030788. [PMID: 33503934 PMCID: PMC7865397 DOI: 10.3390/s21030788] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Revised: 01/18/2021] [Accepted: 01/22/2021] [Indexed: 12/18/2022]
Abstract
Aggregation of amyloid-β (aβ) peptides into toxic oligomers, fibrils, and plaques is central in the molecular pathogenesis of Alzheimer’s disease (AD) and is the primary focus of AD diagnostics. Disaggregation or elimination of toxic aβ aggregates in patients is important for delaying the progression of neurodegenerative disorders in AD. Recently, 4-(2-hydroxyethyl)-1-piperazinepropanesulfonic acid (EPPS) was introduced as a chemical agent that binds with toxic aβ aggregates and transforms them into monomers to reduce the negative effects of aβ aggregates in the brain. However, the mechanism of aβ disaggregation by EPPS has not yet been completely clarified. In this study, an electrochemical impedimetric immunosensor for aβ diagnostics was developed by immobilizing a specific anti-amyloid-β (aβ) antibody onto a self-assembled monolayer functionalized with a new interdigitated chain-shaped electrode (anti-aβ/SAM/ICE). To investigate the ability of EPPS in recognizing AD by extricating aβ aggregation, commercially available aβ aggregates (aβagg) were used. Electrochemical impedance spectroscopy was used to probe the changes in charge transfer resistance (Rct) of the immunosensor after the specific binding of biosensor with aβagg. The subsequent incubation of the aβagg complex with a specific concentration of EPPS at different time intervals divulged AD progression. The decline in the Rct of the immunosensor started at 10 min of EPPS incubation and continued to decrease gradually from 20 min, indicating that the accumulation of aβagg on the surface of the anti-aβ/SAM/ICE sensor has been extricated. Here, the kinetic disaggregation rate k value of aβagg was found to be 0.038. This innovative study using electrochemical measurement to investigate the mechanism of aβagg disaggregation by EPPS could provide a new perspective in monitoring the disaggregation periods of aβagg from oligomeric to monomeric form, and then support for the prediction and handling AD symptoms at different stages after treatment by a drug, EPPS.
Collapse
Affiliation(s)
- Hien T. Ngoc Le
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Korea;
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Korea;
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea
- Correspondence: ; Tel.: +82-(31)-750-5321
| |
Collapse
|
22
|
Electrochemical Immunosensor for the Early Detection of Rheumatoid Arthritis Biomarker: Anti-Cyclic Citrullinated Peptide Antibody in Human Serum Based on Avidin-Biotin System. SENSORS 2020; 21:s21010124. [PMID: 33379138 PMCID: PMC7795521 DOI: 10.3390/s21010124] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 12/21/2020] [Accepted: 12/24/2020] [Indexed: 12/19/2022]
Abstract
Rheumatoid arthritis (RA) is a chronic autoimmune disease that produces a progressive inflammatory response that leads to severe pain, swelling, and stiffness in the joints of hands and feet, followed by irreversible damage of the joints. The authors developed a miniaturized, label-free electrochemical impedimetric immunosensor for the sensitive and direct detection of arthritis Anti-CCP-ab biomarker. An interdigitated-chain-shaped microelectrode array (ICE) was fabricated by taking the advantage of microelectromechanical systems. The fabricated ICE was modified with a self-assembled monolayer (SAM) of Mercaptohexanoic acid (MHA) for immobilization of the synthetic peptide bio-receptor (B-CCP). The B-CCP was attached onto the surface of SAM modified ICE through a strong avidin-biotin bio-recognition system. The modified ICE surface with the SAM and bio-molecules (Avidin, B-CCP, Anti-CCP-ab and BSA) was morphologically and electrochemically characterized. The change in the sensor signal upon analyte binding on the electrode surface was probed through the electrochemical impedance spectroscopy (EIS) property of charge-transfer resistance (Rct) of the modified electrodes. EIS measurements were target specific and the sensor response was linearly increased with step wise increase in target analyte (Anti-CCP-ab) concentrations. The developed sensor showed a linear range for the addition of Anti-CCP-ab between 1 IU mL−1 → 800 IU mL−1 in phosphate buffered saline (PBS) and Human serum (HS), respectively. The sensor showed a limit of detection of 0.60 IU mL−1 and 0.82 IU mL−1 in the PBS and HS, respectively. The develop bio-electrode showed a good reproducibility (relative standard deviation (RSD), 1.52%), selectivity and stability (1.5% lost at the end of 20th day) with an acceptable recovery rate (98.0% → 101.18%) and % RSD’s for the detection of Anti-CCP-ab in spiked HS samples.
Collapse
|
23
|
Le HTN, Park J, Cho S. A Probeless Capacitive Biosensor for Direct Detection of Amyloid Beta 1-42 in Human Serum Based on an Interdigitated Chain-Shaped Electrode. MICROMACHINES 2020; 11:E791. [PMID: 32825726 PMCID: PMC7569882 DOI: 10.3390/mi11090791] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 08/19/2020] [Accepted: 08/19/2020] [Indexed: 12/16/2022]
Abstract
Amyloid beta (aβ) 1-42, a peptide that is 1-42 amino acids long, is a major component of senile plaques in the brains of patients with Alzheimer's disease. Aβ detection has become an essential antecedence to predict the declining mental abilities of patients. In this paper, a probeless capacitive biosensor for the non-Faradaic detection of aβ 1-42 peptide was developed by immobilizing a specific anti-aβ antibody onto a self-assembled monolayer functionalized interdigitated chain-shaped electrode (anti-aβ/SAM/ICE). The novelty and difference of this article from previous studies is the direct detection of aβ peptide with no redox probe ((Fe(CN)6)3-/4-), which can avoid the denaturation of the protein caused by the metallization (binding of aβ to metal ion Fe which is presented in the redox couple). The direct detection of aβ with no redox probe is performed by non-Faradaic capacitive measurement, which is greatly different from the Faradaic measurement of the charge transfer resistance of the redox probe. The detection of various aβ 1-42 peptide concentrations in human serum (HS) was performed by measuring the relative change in electrode interfacial capacitance due to the specific antibody-aβ binding. Capacitance change in the anti-aβ/SAM/ICE biosensor showed a linear detection range between 10 pg mL-1 and 104 pg mL-1, and a detection limit of 7.5 pg mL-1 in HS, which was much lower than the limit of detection for CSF aβ 1-42 (~500 pg mL-1) and other biosensors. The small dissociation constant Kd of the antibody-antigen interaction was also found to be 0.016 nM in HS, indicating the high binding affinity of the anti-aβ/SAM/ICE biosensor in the recognizing of aβ 1-42. Thus, the developed sensor can be used for label-free and direct measurement of aβ 1-42 peptide and for point-of-care diagnosis of Alzheimer's disease without redox probe.
Collapse
Affiliation(s)
- Hien T. Ngoc Le
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Korea;
| | - Jinsoo Park
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea;
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Korea;
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea;
| |
Collapse
|
24
|
Yagati AK, Ngoc Le HT, Cho S. Bioelectrocatalysis of Hemoglobin on Electrodeposited Ag Nanoflowers toward H 2O 2 Detection. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E1628. [PMID: 32825146 PMCID: PMC7557759 DOI: 10.3390/nano10091628] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 08/11/2020] [Accepted: 08/13/2020] [Indexed: 11/29/2022]
Abstract
Hydrogen peroxide (H2O2) is a partially reduced metabolite of oxygen that exerts a diverse array of physiological and pathological activities in living organisms. Therefore, the accurate quantitative determination of H2O2 is crucial in clinical diagnostics, the food industry, and environmental monitoring. Herein we report the electrosynthesis of silver nanoflowers (AgNFs) on indium tin oxide (ITO) electrodes for direct electron transfer of hemoglobin (Hb) toward the selective quantification of H2O2. After well-ordered and fully-grown AgNFs were created on an ITO substrate by electrodeposition, their morphological and optical properties were analyzed with scanning electron microscopy and UV-Vis spectroscopy. Hb was immobilized on 3-mercaptopropionic acid-coated AgNFs through carbodiimide cross-linking to form an Hb/AgNF/ITO biosensor. Electrochemical measurement and analysis demonstrated that Hb retained its direct electron transfer and electrocatalytic properties and acted as a H2O2 sensor with a detection limit of 0.12 µM and a linear detection range of 0.2 to 3.4 mM in phosphate-buffered saline (PBS). The sensitivity, detection limit, and detection range of the Hb/AgNF/ITO biosensor toward detection H2O2 in human serum was also found to be 0.730 mA mM-1 cm-2, 90 µM, and 0.2 to 2.6 mM, indicating the clinical application for the H2O2 detection of the Hb/AgNF/ITO biosensor. Moreover, interference experiments revealed that the Hb/AgNF/ITO sensor displayed excellent selectivity for H2O2.
Collapse
Affiliation(s)
- Ajay Kumar Yagati
- Institute of Analytical Chemistry, Chemo- and Biosensors, Universität Regensburg, 93053 Regensburg, Germany;
| | - Hien T. Ngoc Le
- Department of Electronics Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13210, Korea;
| | - Sungbo Cho
- Department of Electronics Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13210, Korea;
- Gachon Advanced Institute for Health Science & Technology, Gachon University, Incheon 21999, Korea
| |
Collapse
|
25
|
Park D, Kim JH, Kim HJ, Lee D, Lee DS, Yoon DS, Hwang KS. Multiplexed femtomolar detection of Alzheimer's disease biomarkers in biofluids using a reduced graphene oxide field-effect transistor. Biosens Bioelectron 2020; 167:112505. [PMID: 32841782 DOI: 10.1016/j.bios.2020.112505] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 07/31/2020] [Accepted: 08/07/2020] [Indexed: 12/11/2022]
Abstract
Alzheimer's disease (AD) is a neurodegenerative disease that accounts for 70% of all dementia. Early stage diagnosis of AD is essential as there is no certain treatment after the lesion has progressed in the late stage. Nevertheless, there are still limitations of early diagnosis of AD using neuroimaging and psychological memory assessments. Here, we demonstrate ultrasensitive and multiplexed detection of pivotal AD biomarkers (Aβ1-42 and t-Tau) in biofluids using a reduced graphene oxide field-effect transistor (gFET). The proposed approach provides a wide logarithmically linear range of detection from 10-1-105 pg mL-1 and a femtomolar-level limit of detection in biofluids (human plasma and artificial cerebrospinal fluid) as well as phosphate-buffered saline (PBS). Furthermore, as these core biomarkers have different surface charges in physiological conditions based on the isoelectric point (pI), we achieved a distinctive output signal for each biomarker. The gFET biosensor platform presented in this paper has great potential and can be used for early diagnosis of AD in clinical practice as well as accurate analysis based on the surface charge of the analytes.
Collapse
Affiliation(s)
- Dongsung Park
- Department of Clinical Pharmacology and Therapeutics, College of Medicine, Kyung Hee University, Seoul, 02453, Republic of Korea; School of Biomedical Engineering, Korea University, Seoul, 02841, Republic of Korea
| | - Jae Hyun Kim
- Department of Clinical Pharmacology and Therapeutics, College of Medicine, Kyung Hee University, Seoul, 02453, Republic of Korea
| | - Hye Jin Kim
- Department of Clinical Pharmacology and Therapeutics, College of Medicine, Kyung Hee University, Seoul, 02453, Republic of Korea
| | - Dongtak Lee
- School of Biomedical Engineering, Korea University, Seoul, 02841, Republic of Korea
| | - David S Lee
- Department of Clinical Pharmacology and Therapeutics, College of Medicine, Kyung Hee University, Seoul, 02453, Republic of Korea
| | - Dae Sung Yoon
- School of Biomedical Engineering, Korea University, Seoul, 02841, Republic of Korea.
| | - Kyo Seon Hwang
- Department of Clinical Pharmacology and Therapeutics, College of Medicine, Kyung Hee University, Seoul, 02453, Republic of Korea.
| |
Collapse
|
26
|
Li G, Sun X, Wan X, Wang D. Lactoferrin-Loaded PEG/PLA Block Copolymer Targeted With Anti-Transferrin Receptor Antibodies for Alzheimer Disease. Dose Response 2020; 18:1559325820917836. [PMID: 32863801 PMCID: PMC7430085 DOI: 10.1177/1559325820917836] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 02/19/2020] [Accepted: 02/25/2020] [Indexed: 11/15/2022] Open
Abstract
Last few years, struggles have been reported to develop the nanovesicles for drug delivery via the brain-blood barrier (BBB). Novel drugs, for instance, iAβ5, are efficient to inhibit the aggregates connected to the treatment of Alzheimer disease and are being evaluated, but most of the reports reflect some drawbacks of the drugs to reach the brain in preferred concentrations owing to the less BBB penetrability of the surface dimensions. In this report, we designed and developed a new approach to enhance the transport of drug via BBB, constructed with lactoferrin (Lf)-coated polyethylene glycol-polylactide nanoparticles (Lf-PPN) with superficial monoclonal antibody-functionalized antitransferrin receptor and anti-Aβ to deliver the iAβ5 hooked on the brain. The porcine brain capillary endothelial cells were utilized as BBB typically to examine the framework efficacy and toxicity. The cellular uptake of the immuno-nanoparticles with measured conveyance of the iAβ5 peptide was significantly enhanced and associated with Lf-PPN without monoclonal antibody functionalizations.
Collapse
Affiliation(s)
- Guichen Li
- Department of Clinical Psychology, Qingdao Mental Health Center, Qingdao, China
| | - Xianghong Sun
- Second Elderly Ward, Qingdao Mental Health Center, Qingdao, China
| | - Xiaona Wan
- Second Elderly Ward, Qingdao Mental Health Center, Qingdao, China
| | - Dongming Wang
- Second Elderly Ward, Qingdao Mental Health Center, Qingdao, China
| |
Collapse
|
27
|
Sethi J, Van Bulck M, Suhail A, Safarzadeh M, Perez-Castillo A, Pan G. A label-free biosensor based on graphene and reduced graphene oxide dual-layer for electrochemical determination of beta-amyloid biomarkers. Mikrochim Acta 2020; 187:288. [PMID: 32333119 PMCID: PMC7182627 DOI: 10.1007/s00604-020-04267-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Accepted: 04/10/2020] [Indexed: 01/03/2023]
Abstract
A label-free biosensor is developed for the determination of plasma-based Aβ1–42 biomarker in Alzheimer’s disease (AD). The platform is based on highly conductive dual-layer of graphene and electrochemically reduced graphene oxide (rGO). The modification of dual-layer with 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS) is achieved to facilitate immobilization of H31L21 antibody. The effect of these modifications were studied with morphological, spectral and electrochemical techniques. The response of the biosensor was evaluated using differential pulse voltammetry (DPV). The data was acquired at a working potential of ~ 180 mV and a scan rate of 50 mV s−1. A low limit of detection (LOD) of 2.398 pM is achieved over a wide linear range from 11 pM to 55 nM. The biosensor exhibits excellent specificity over Aβ1–40 and ApoE ε4 interfering species. Thus, it provides a viable tool for electrochemical determination of Aβ1–42. Spiked human and mice plasmas were used for the successful validation of the sensing platform in bio-fluidic samples. The results obtained from mice plasma analysis concurred with the immunohistochemistry (IHC) and magnetic resonance imaging (MRI) data obtained from brain analysis. Schematic representation of the electrochemical system proposed for Aβ1–42 determination: (a) modification of graphene screen-printed electrode (SPE) with monolayer graphene oxide (GO) followed by its electrochemical reduction generating graphene/reduced graphene oxide (rGO) dual-layer (b), modification of dual-layer with linker (c), Aβ1–42 antibody (H31L21) (d), bovine serum albumin (BSA) (e) and Aβ1–42 peptide (f). ![]()
Collapse
Affiliation(s)
- Jagriti Sethi
- Wolfson Nanomagnetics Laboratory, School of Engineering, Computing and Mathematics, University of Plymouth, Devon, PL4 8AA, UK.
| | - Michiel Van Bulck
- Instituto de Investigaciones Biomédicas (CSIC-UAM), Arturo Duperier, 4, 28029, Madrid, Spain.,Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Valderrebollo, 5, 28031, Madrid, Spain
| | - Ahmed Suhail
- Wolfson Nanomagnetics Laboratory, School of Engineering, Computing and Mathematics, University of Plymouth, Devon, PL4 8AA, UK
| | - Mina Safarzadeh
- Wolfson Nanomagnetics Laboratory, School of Engineering, Computing and Mathematics, University of Plymouth, Devon, PL4 8AA, UK
| | - Ana Perez-Castillo
- Instituto de Investigaciones Biomédicas (CSIC-UAM), Arturo Duperier, 4, 28029, Madrid, Spain.,Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Valderrebollo, 5, 28031, Madrid, Spain
| | - Genhua Pan
- Wolfson Nanomagnetics Laboratory, School of Engineering, Computing and Mathematics, University of Plymouth, Devon, PL4 8AA, UK
| |
Collapse
|
28
|
Zhou Y, Liu J, Zheng T, Tian Y. Label-Free SERS Strategy for In Situ Monitoring and Real-Time Imaging of Aβ Aggregation Process in Live Neurons and Brain Tissues. Anal Chem 2020; 92:5910-5920. [PMID: 32227892 DOI: 10.1021/acs.analchem.9b05837] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The aggregation of Aβ has been reported to closely correlate with Alzheimer's disease (AD). However, clear monitoring of the entire aggregation process of Aβ from monomer to fibril has been scarcely reported until now. Herein, we developed a label-free ratiometric surface enhanced Raman spectroscopic (SERS) platform for real-time monitoring of the entire process of Aβ aggregation in neurons and brain tissues. Different gold nanoparticles, generated in situ with Aβ monomer and fibril as templates separately, were served as effective SERS substrates to achieve a high sensitivity with a limit of detection (LOD) down to 70 ± 4 pM and 3.0 ± 0.5 pM for Aβ40 monomer and fibrils, respectively. Besides, the introduction of ratiometric determination of Aβ monomer and fibril (I1244/I1268) realized real-time monitoring of the entire aggregation process of Aβ monomer with high accuracy and selectivity against other proteins and amino acids. The significant analytical performance of the developed platform, together with good biocompatibility, long-term stability, and remarkable spatial resolution, enabled the present SERS platform imaging and real-time monitoring and imaging of Aβ aggregation influenced by different metal ions (Cu2+, Zn2+, and Fe3+) in neurons and brain tissues at the single cell level. Our results suggested that Cu2+ and Zn2+ ion of low concentration (10 μM) promoted fibril formation, while Fe3+ and Zn2+ of high concentration (100 μM) showed inhibition of fibrosis.
Collapse
Affiliation(s)
- Yan Zhou
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, P. R. China
| | - Jia Liu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, P. R. China
| | - Tingting Zheng
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, P. R. China
| | - Yang Tian
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, P. R. China
| |
Collapse
|
29
|
Devi R, Gogoi S, Dutta HS, Bordoloi M, Sanghi SK, Khan R. Au/NiFe 2O 4 nanoparticle-decorated graphene oxide nanosheets for electrochemical immunosensing of amyloid beta peptide. NANOSCALE ADVANCES 2020; 2:239-248. [PMID: 36133989 PMCID: PMC9417307 DOI: 10.1039/c9na00578a] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 11/04/2019] [Indexed: 05/29/2023]
Abstract
In the present work, an electrochemical immunosensor has been fabricated for the detection of amyloid beta peptide (βA1--42) based on a gold nanoparticle/nickel ferrite decorated graphene oxide-chitosan nanocomposite (Au/NiFe2O4@GO-Ch) modified glassy carbon electrode (GCE) as an effective sensing platform. βA1-42 has been analyzed as a potential biomarker for its application in Alzheimer's disease monitoring. The combination of highly conducting Au and NiFe2O4 nanoparticles on two-dimensional GO nanosheets provides an excellent platform for sensitive and selective sensing applications. A miniaturized Au/NiFe2O4@GO-Ch/GCE immunosensor was prepared by immobilization of βA antibody onto Au//NiFe2O4@GO-Ch/GCE via carbodiimide coupling. Various characterization techniques were utilized in the study to estimate the morphological and electronic attributes of the components used to fabricate the immunosensor. Differential pulse voltammetry (DPV) was performed to study the amperometric response of the developed immunosensor as a function of βA1-42 concentration. The DPV results confirmed that the immunosensor detected βA1-42 selectively and demonstrated a wide linear range from 1 pg mL-1 to 1 ng mL-1 and a detection limit of 3.0 pg mL-1. Furthermore, the immunosensor also indicated its clinical viability by detecting βA1-42 in cerebrospinal fluid.
Collapse
Affiliation(s)
- Rashmita Devi
- Analytical Chemistry Group, Material Sciences and Technology Division, CSIR-North East Institute of Science & Technology (CSIR-NEIST) Jorhat-785006 India
- Academy of Scientific and Innovative Research (AcSIR), CSIR-NEIST Campus Jorhat India
| | - Satyabrat Gogoi
- Analytical Chemistry Group, Material Sciences and Technology Division, CSIR-North East Institute of Science & Technology (CSIR-NEIST) Jorhat-785006 India
| | - Hemant Sankar Dutta
- Analytical Chemistry Group, Material Sciences and Technology Division, CSIR-North East Institute of Science & Technology (CSIR-NEIST) Jorhat-785006 India
- Academy of Scientific and Innovative Research (AcSIR), CSIR-NEIST Campus Jorhat India
| | - Manobjyoti Bordoloi
- Academy of Scientific and Innovative Research (AcSIR), CSIR-NEIST Campus Jorhat India
- Natural Product Chemistry Group, Chemical Sciences and Technology Division, CSIR-NEIST Jorhat-785006 Assam India
| | - Sunil K Sanghi
- Microfluidics & MEMS Centre, CSIR-Advanced Materials and Processes Research Institute (CSIR-AMPRI) Bhopal-462026 MP India
| | - Raju Khan
- Microfluidics & MEMS Centre, CSIR-Advanced Materials and Processes Research Institute (CSIR-AMPRI) Bhopal-462026 MP India
| |
Collapse
|