1
|
Raju G, Ranjan A, Banik S, Poddar A, Managuli V, Mazumder N. A commentary on the development and use of smartphone imaging devices. Biophys Rev 2024; 16:151-163. [PMID: 38737211 PMCID: PMC11078910 DOI: 10.1007/s12551-023-01175-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 12/04/2023] [Indexed: 05/14/2024] Open
Abstract
Current-age smartphones are known for their wide array of functionality and are now being utilized in the field of healthcare and medicine due to their proven capabilities as smartphone imaging devices (SIDs). Recent technical advancements enabled the integration of special add-on lenses with smartphones to transform them into SIDs. With the rising demand for efficient point-of-care (PoC) devices for better diagnostic applications, SIDs will be a one-stop solution. Additionally, portability, user-friendliness and low-cost make it accessible for all even at remote locations. Furthermore, improvements in resolution, magnification and field-of-view (FOV) have attracted the scientific community to use SIDs in various biomedical applications such as disease diagnosis, food quality control and pathogen detection. SIDs can be arranged in various combinational setups by using different illumination sources and optics to achieve suitable contrast and visibility of the specimen under study. This Commentary illustrates the various illumination sources used in SID and also spotlights their design and applications.
Collapse
Affiliation(s)
- Gagan Raju
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka 576104 India
| | - Aashrayi Ranjan
- Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104 India
| | - Soumyabrata Banik
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka 576104 India
| | - Ashmini Poddar
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka 576104 India
| | - Vishwanath Managuli
- Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104 India
| | - Nirmal Mazumder
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka 576104 India
| |
Collapse
|
2
|
Rubio JMB, Moyà-Alcover G, Jaume-I-Capó A, Petrović N. Crowdsourced human-based computational approach for tagging peripheral blood smear sample images from Sickle Cell Disease patients using non-expert users. Sci Rep 2024; 14:1201. [PMID: 38216623 PMCID: PMC10786843 DOI: 10.1038/s41598-024-51591-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 01/07/2024] [Indexed: 01/14/2024] Open
Abstract
In this paper, we present a human-based computation approach for the analysis of peripheral blood smear (PBS) images images in patients with Sickle Cell Disease (SCD). We used the Mechanical Turk microtask market to crowdsource the labeling of PBS images. We then use the expert-tagged erythrocytesIDB dataset to assess the accuracy and reliability of our proposal. Our results showed that when a robust consensus is achieved among the Mechanical Turk workers, probability of error is very low, based on comparison with expert analysis. This suggests that our proposed approach can be used to annotate datasets of PBS images, which can then be used to train automated methods for the diagnosis of SCD. In future work, we plan to explore the potential integration of our findings with outcomes obtained through automated methodologies. This could lead to the development of more accurate and reliable methods for the diagnosis of SCD.
Collapse
Affiliation(s)
- José María Buades Rubio
- UGiVIA Research Group, Department of Mathematics and Computer Science, University of the Balearic Islands, 07122, Palma, Spain
| | - Gabriel Moyà-Alcover
- UGiVIA Research Group, Department of Mathematics and Computer Science, University of the Balearic Islands, 07122, Palma, Spain
- Laboratory for Artificial Intelligence Applications (LAIA@UIB), University of the Balearic Islands, 07122, Palma, Spain
| | - Antoni Jaume-I-Capó
- UGiVIA Research Group, Department of Mathematics and Computer Science, University of the Balearic Islands, 07122, Palma, Spain.
- Laboratory for Artificial Intelligence Applications (LAIA@UIB), University of the Balearic Islands, 07122, Palma, Spain.
| | - Nataša Petrović
- UGiVIA Research Group, Department of Mathematics and Computer Science, University of the Balearic Islands, 07122, Palma, Spain
| |
Collapse
|
3
|
Moetlhoa B, Maluleke K, Mathebula EM, Kgarosi K, Nxele SR, Lenonyane B, Mashamba-Thompson T. REASSURED diagnostics at point-of-care in sub-Saharan Africa: A scoping review. PLOS GLOBAL PUBLIC HEALTH 2023; 3:e0001443. [PMID: 37276194 DOI: 10.1371/journal.pgph.0001443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 05/12/2023] [Indexed: 06/07/2023]
Abstract
Point-of-care (POC) diagnostics that meet the REASSURED criteria are essential in combating the rapid increase and severity of global health emergencies caused by infectious diseases. However, little is known about whether the REASSURED criteria are implemented in regions known to have a high burden of infectious diseases such as sub-Saharan Africa (SSA). This scoping review maps evidence of the use of REASSURED POC diagnostic tests in SSA. The scoping review was guided by the advanced methodological framework of Arksey and O'Malley, and Levac et al. We searched the following electronic databases for relevant literature: Scopus, Dimensions, ProQuest Central, Google Scholar, and EBSCOhost (MEDLINE, CINAHL, as well as AFRICA-WIDE). Two reviewers independently screened abstracts and full-text articles using the inclusion criteria as reference. We appraised the quality of the included studies using the mixed-method appraisal tool (MMAT) version 2018. We retrieved 138 publications, comprising 134 articles and four grey literature articles. Of these, only five articles were included following abstract and full-text screening. The five included studies were all conducted in SSA. The following themes emerged from the eligible articles: quality assurance on accuracy of REASSURED POC diagnostic tests, sustainability of REASSURED POC diagnostic tests, and local infrastructure capability for delivering REASSURED POC diagnostic tests to end users. All five articles had MMAT scores between 90% and 100%. In conclusion, our scoping review revealed limited published research on REASSURED diagnostics at POC in SSA. We recommend primary studies aimed at investigating the implementation of REASSURED POC diagnostic tests in SSA.
Collapse
Affiliation(s)
- Boitumelo Moetlhoa
- Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Kuhlula Maluleke
- Faculty of Health Sciences, School of Health Systems and Public Health, University of Pretoria, Pretoria, South Africa
| | - Evans M Mathebula
- Faculty of Health Sciences, School of Health Systems and Public Health, University of Pretoria, Pretoria, South Africa
- Medical and Scientific Affairs, Rapid Diagnostics, Infectious Diseases Emerging Markets, Abbot Rapid Diagnostics (Pty) Ltd, Sandton, South Africa
| | - Kabelo Kgarosi
- Faculty of Health Sciences, Department of Library Services, University of Pretoria, Pretoria, South Africa
| | - Siphesihle R Nxele
- Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Bonolo Lenonyane
- Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | | |
Collapse
|
4
|
Zhang W, Li Y, Chen B, Zhang Y, Du Z, Xiang F, Hu Y, Meng X, Shang C, Liang S, Yang X, Guan W. Fully integrated point-of-care blood cell count using multi-frame morphology analysis. Biosens Bioelectron 2023; 223:115012. [PMID: 36542936 DOI: 10.1016/j.bios.2022.115012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/29/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022]
Abstract
Point-of-care testing (POCT) of blood cell count (BCC) is an emerging approach that allows laypersons to identify and count whole blood cells through simple manipulation. To date, POCTs for BCC were mainly achieved by "stationary" images through blood smears or single-laity arranged cells in the microwell, making it difficult to obtain statistically sufficient numbers of cells. In this work, we present a fully integrated POCT device solely using "in-flow" imaging of 3 μL fingertip whole blood for improved identification and counting accuracy of BCC analysis. A miniaturized magnetic stirring module was integrated to maintain the temporal stability of cell concentration. A relatively high throughput (∼8000 cells/min) with a 30-fold dilution ratio of whole blood can be tested for as long as 1 h to examine sufficient numbers of cells, and the subclass cell concentration keeps constant. To improve the identification accuracy, multi-frame "in-flow" imaging was used to track the cell motion trails with multi-angle morphology analysis. This proof-of-concept was then validated with healthy whole blood samples and 75 cases of clinical patients with abnormal concentrations of red blood cells (RBCs), white blood cells (WBCs), and platelets (PLT). The average precision (AP) value of WBCs identification was improved from 0.8622 to 0.9934 using the multi-frame analysis method. And the high fitting degrees (>0.98) between our POCT device and the commercial clinical equipment indicated good agreement. This POCT device is user-friendly and cost-effective, making it a potential tool for diagnosing abnormal blood cell morphology or concentration in the field setting.
Collapse
Affiliation(s)
- Wenchang Zhang
- Key Lab of Microelectronic Devices & Integrated Technology, Institute of Microelectronics, Chinese Academy of Sciences, Beijing, 100029, China.
| | - Ya Li
- Department of Gastroenterology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Bing Chen
- Department of Gastroenterology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Yuan Zhang
- Key Clinical Laboratory of Henan Province, Department of Clinical Laboratory, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China
| | - Ziqiang Du
- School of Information Engineering, Zhengzhou University, Zhengzhou, 450001, China
| | - Feibin Xiang
- Key Lab of Microelectronic Devices & Integrated Technology, Institute of Microelectronics, Chinese Academy of Sciences, Beijing, 100029, China
| | - Yu Hu
- School of Information Engineering, Zhengzhou University, Zhengzhou, 450001, China
| | - Xiaochen Meng
- Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science & Technology University, Beijing, 100192, China
| | - Chunliang Shang
- Department of Obstetrics and Gynecology, Peking University Third Hospital, Beijing, 100191, China
| | - Shengfa Liang
- Key Lab of Microelectronic Devices & Integrated Technology, Institute of Microelectronics, Chinese Academy of Sciences, Beijing, 100029, China
| | - Xiaonan Yang
- School of Information Engineering, Zhengzhou University, Zhengzhou, 450001, China.
| | - Weihua Guan
- Department of Electrical Engineering, Pennsylvania State University, University Park, 16802, USA; Department of Biomedical Engineering, Pennsylvania State University, University Park, 16802, USA.
| |
Collapse
|
5
|
Lu S, Ma B, Zhou H, Li Y, Qiao Z, Xiao T, Li H, Wang B, Cui M, Zhang S, Chang J, Du T, Liu J, Wang H. Smartphone recognition-based immune microparticles for rapid on-site visual data-sharing detection of Newcastle disease virus. Talanta 2023; 252:123845. [DOI: 10.1016/j.talanta.2022.123845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 08/02/2022] [Accepted: 08/12/2022] [Indexed: 10/15/2022]
|
6
|
S A, Ganesan K, K BB. A novel deep learning approach for sickle cell anemia detection in human RBCs using an improved wrapper-based feature selection technique in microscopic blood smear images. BIOMED ENG-BIOMED TE 2022; 68:175-185. [PMID: 36197949 DOI: 10.1515/bmt-2021-0127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 09/13/2022] [Indexed: 11/15/2022]
Abstract
Sickle Cell Anemia (SCA) is a disorder in Red Blood Cells (RBCs) of human blood. Children under five years and pregnant women are mostly affected by SCA. Early diagnosis of this ailment can save lives. In recent years, the computer aided diagnosis of SCA is preferred to resolve this issue. A novel and effective deep learning approach for identification of sickle cell anemia is proposed in this work. Around nine hundred microscopic images of human red blood cells are obtained from the public database 'erythrocytes IDB'. All the images are resized uniformly. About 2048 deep features are extracted from the fully connected layer of pre-trained model InceptionV3. These features are further subjected to classification using optimization-based methods. An improved wrapper-based feature selection technique is implemented using Multi- Objective Binary Grey Wolf Optimization (MO-BGWO) approach with KNN and SVM for classification. The detection of sickle cell is also performed using typical InceptionV3 model by using SoftMax layer. It is observed that the performance of the proposed system seems to be high when compared to the classification using the original InceptionV3 model. The results are validated by various evaluation metrics such as accuracy, precision, sensitivity, specificity and F1-score. The SVM classifier yields high accuracy of about 96%. The optimal subset of deep features along with SVM enhances the system performance in the proposed work. Thus, the proposed approach is appropriate for pathologists to take early clinical decisions on detection of sickle cells.
Collapse
Affiliation(s)
- Alagu S
- Department of Electronics Engineering, Madras Institute of Technology, Chennai, India
| | - Kavitha Ganesan
- Department of Electronics Engineering, Madras Institute of Technology, Chennai, India
| | - Bhoopathy Bagan K
- Department of Electronics Engineering, Madras Institute of Technology, Chennai, India
| |
Collapse
|
7
|
A smart tablet-phone-based system using dynamic light modulation for highly sensitive colorimetric biosensing. Talanta 2022; 252:123862. [DOI: 10.1016/j.talanta.2022.123862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 08/09/2022] [Accepted: 08/18/2022] [Indexed: 11/20/2022]
|
8
|
A ratiometric fluorescence platform based on carbon dots for visual and rapid detection of copper(II) and fluoroquinolones. Mikrochim Acta 2022; 189:144. [PMID: 35292904 DOI: 10.1007/s00604-022-05243-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2021] [Accepted: 02/22/2022] [Indexed: 10/25/2022]
Abstract
A simple smartphone-integrated ratiometric fluorescent sensing system for visual determination of copper ions (Cu2+) and fluoroquinolones (FQs) was developed based on carbon dots (CDs) which were synthesized through the high-temperature pyrolysis of citric acid. In this system, with the fluorescence resonance energy transfer effect between CDs and 2,3-diaminophenazine (oxOPD), the detection of Cu2+ and ciprofloxacin (CIP, an example for FQs) was realized. Cu2+ catalyzes the oxidation of OPD to form oxOPD with yellow fluorescence, resulting in the quenching of CDs. In addition, CIP can inhibit the catalytic activity of Cu2+ and induce the recovery of CDs fluorescence. Under the excitation of 400 nm, the changes of CDs fluorescence at 472 nm and oxOPD fluorescence at 556 nm were monitored. The detection results showed that the sensing system exhibited good selectivity and sensitivity to Cu2+ and CIP with the limit of detection of 2.32 × 10-8 mol L-1 and 0.2 ng mL-1, respectively. In addition, a smartphone was developed as a portable analyzer to capture the change of fluorescence color and quickly analyze the concentration of Cu2+ and CIP. The proposed smartphone-based sensing platform has satisfactory sensitivity, and it has application prospects for detecting Cu2+ and FQs in food safety monitoring.
Collapse
|
9
|
Fennell RD, Sher M, Asghar W. Development of a Microfluidic Device for CD4+ T Cell Isolation and Automated Enumeration from Whole Blood. BIOSENSORS 2021; 12:bios12010012. [PMID: 35049640 PMCID: PMC8773767 DOI: 10.3390/bios12010012] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 12/13/2021] [Accepted: 12/24/2021] [Indexed: 12/04/2022]
Abstract
The development of point-of-care, cost-effective, and easy-to-use assays for the accurate counting of CD4+ T cells remains an important focus for HIV-1 disease management. The CD4+ T cell count provides an indication regarding the overall success of HIV-1 treatments. The CD4+ T count information is equally important for both resource-constrained regions and areas with extensive resources. Hospitals and other allied facilities may be overwhelmed by epidemics or other disasters. An assay for a physician’s office or other home-based setting is becoming increasingly popular. We have developed a technology for the rapid quantification of CD4+ T cells. A double antibody selection process, utilizing anti-CD4 and anti-CD3 antibodies, is tested and provides a high specificity. The assay utilizes a microfluidic chip coated with the anti-CD3 antibody, having an improved antibody avidity. As a result of enhanced binding, a higher flow rate can be applied that enables an improved channel washing to reduce non-specific bindings. A wide-field optical imaging system is also developed that provides the rapid quantification of cells. The designed optical setup is portable and low-cost. An ImageJ-based program is developed for the automatic counting of CD4+ T cells. We have successfully isolated and counted CD4+ T cells with high specificity and efficiency greater than 90%.
Collapse
Affiliation(s)
- Robert D. Fennell
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA; (R.D.F.); (M.S.)
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA
| | - Mazhar Sher
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA; (R.D.F.); (M.S.)
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA
| | - Waseem Asghar
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA; (R.D.F.); (M.S.)
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA
- Department of Biological Sciences (Courtesy Appointment), Florida Atlantic University, Boca Raton, FL 33431, USA
- Correspondence:
| |
Collapse
|
10
|
Dieujuste D, Qiang Y, Du E. A portable impedance microflow cytometer for measuring cellular response to hypoxia. Biotechnol Bioeng 2021; 118:4041-4051. [PMID: 34232511 DOI: 10.1002/bit.27879] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 06/04/2021] [Accepted: 06/24/2021] [Indexed: 01/02/2023]
Abstract
This article presents the development and testing of a low-cost (<$60), portable, electrical impedance-based microflow cytometer for single-cell analysis under a controlled oxygen microenvironment. The system is based on an AD5933 impedance analyzer chip, a microfluidic chip, and an Arduino microcontroller operated by a custom Android application. A representative case study on human red blood cells (RBCs) affected by sickle cell disease is conducted to demonstrate the capability of the cytometry system. Impedance values of sickle blood samples exhibit remarkable deviations from the common reference line obtained from two normal blood samples. Such deviation is quantified by a conformity score, which allows for the measurement of intrapatient and interpatient variations of sickle cell disease. A low conformity score under oxygenated conditions or drastically different conformity scores between oxygenated and deoxygenated conditions can be used to differentiate a sickle blood sample from normal. Furthermore, an equivalent circuit model of a suspended biological cell is used to interpret the electrical impedance of single flowing RBCs. In response to hypoxia treatment, all samples, regardless of disease state, exhibit significant changes in at least one single-cell electrical property, that is, cytoplasmic resistance and membrane capacitance. The overall response to hypoxia is less in normal cells than those affected by sickle cell disease, where the change in membrane capacitance varies from -23% to seven times as compared with -17% in normal cells. The results reported in this article suggest that the developed method of testing demonstrates the potential application for a low-cost screening technique for sickle cell disease and other diseases in the field and low-resource settings. The developed system and methodology can be extended to analyze cellular response to hypoxia in other cell types.
Collapse
Affiliation(s)
- Darryl Dieujuste
- Department of Ocean and Mechanical Engineering, and the Department of Biological Sciences, Florida Atlantic University, Boca Raton, Florida, USA
| | - Yuhao Qiang
- Department of Ocean and Mechanical Engineering, and the Department of Biological Sciences, Florida Atlantic University, Boca Raton, Florida, USA
| | - E Du
- Department of Ocean and Mechanical Engineering, and the Department of Biological Sciences, Florida Atlantic University, Boca Raton, Florida, USA
| |
Collapse
|
11
|
Kabir MA, Zilouchian H, Younas MA, Asghar W. Dengue Detection: Advances in Diagnostic Tools from Conventional Technology to Point of Care. BIOSENSORS 2021; 11:206. [PMID: 34201849 PMCID: PMC8301808 DOI: 10.3390/bios11070206] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/05/2021] [Accepted: 06/15/2021] [Indexed: 06/02/2023]
Abstract
The dengue virus (DENV) is a vector-borne flavivirus that infects around 390 million individuals each year with 2.5 billion being in danger. Having access to testing is paramount in preventing future infections and receiving adequate treatment. Currently, there are numerous conventional methods for DENV testing, such as NS1 based antigen testing, IgM/IgG antibody testing, and Polymerase Chain Reaction (PCR). In addition, novel methods are emerging that can cut both cost and time. Such methods can be effective in rural and low-income areas throughout the world. In this paper, we discuss the structural evolution of the virus followed by a comprehensive review of current dengue detection strategies and methods that are being developed or commercialized. We also discuss the state of art biosensing technologies, evaluated their performance and outline strategies to address challenges posed by the disease. Further, we outline future guidelines for the improved usage of diagnostic tools during recurrence or future outbreaks of DENV.
Collapse
Affiliation(s)
- Md Alamgir Kabir
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA; (M.A.K.); (H.Z.)
- Department of Computer & Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA
| | - Hussein Zilouchian
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA; (M.A.K.); (H.Z.)
- College of Medicine, University of Central Florida, Orlando, FL 32827, USA
| | | | - Waseem Asghar
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA; (M.A.K.); (H.Z.)
- Department of Computer & Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA
- Department of Biological Sciences (Courtesy Appointment), Florida Atlantic University, Boca Raton, FL 33431, USA
| |
Collapse
|
12
|
Techniques for the Detection of Sickle Cell Disease: A Review. MICROMACHINES 2021; 12:mi12050519. [PMID: 34063111 PMCID: PMC8148117 DOI: 10.3390/mi12050519] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 04/17/2021] [Accepted: 04/25/2021] [Indexed: 12/14/2022]
Abstract
Sickle cell disease (SCD) is a widespread disease caused by a mutation in the beta-globin gene that leads to the production of abnormal hemoglobin called hemoglobin S. The inheritance of the mutation could be homozygous or heterozygous combined with another hemoglobin mutation. SCD can be characterized by the presence of dense, sickled cells that causes hemolysis of blood cells, anemia, painful episodes, organ damage, and in some cases death. Early detection of SCD can help to reduce the mortality and manage the disease effectively. Therefore, different techniques have been developed to detect the sickle cell disease and the carrier states with high sensitivity and specificity. These techniques can be screening tests such as complete blood count, peripheral blood smears, and sickling test; confirmatory tests such as hemoglobin separation techniques; and genetic tests, which are more expensive and need to be done in centralized labs by highly skilled personnel. However, advanced portable point of care techniques have been developed to provide a low-cost, simple, and user-friendly device for detecting SCD, for instance coupling solubility tests with portable devices, using smartphone microscopic classifications, image processing techniques, rapid immunoassays, and sensor-based platforms. This review provides an overview of the current and emerging techniques for sickle cell disease detection and highlights the different potential methods that could be applied to help the early diagnosis of SCD.
Collapse
|
13
|
Devanesan S, AlSalhi MS, Masilamani V, Alqahtany F, Rajasekar A, Alenazi A, Farhat K. Fluorescence spectroscopy as a novel technique for premarital screening of sickle cell disorders. Photodiagnosis Photodyn Ther 2021; 34:102276. [PMID: 33798750 DOI: 10.1016/j.pdpdt.2021.102276] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 02/09/2021] [Accepted: 03/26/2021] [Indexed: 12/01/2022]
Abstract
Spectral diagnostic screening for sickle cell disease was carried out on volunteer blood samples (N = 100). The samples were subjected to different diagnostic methods including conventional complete blood count (CBC), hemoglobin electrophoresis (HBE) and spectral diagnosis. For the spectral diagnostic method, we discriminated three different characteristic spectral features. In total, 15 samples were sickle cell trait (SCT), 34 samples were sickle cell disease (SCD), and the rest of the samples (N = 51) were normal controls. The spectral discrimination of the three different sets of samples was distinguished on the quantification of fluorescent biomolecules such as tyrosine, tryptophan, NADH, FAD, and porphyrins. The results were compared with the conventional standard CBC and capillary electrophoresis findings. The spectral diagnosis method exhibited a sensitivity and specificity greater than 90 % for the tested samples. This technique requires only 5 mL blood samples, has an analysis time of 20 min, exhibits high accuracy and may be used in small clinics in remote villages.
Collapse
Affiliation(s)
- Sandhanasamy Devanesan
- Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box -2455, Riyadh, 11451, Saudi Arabia
| | - Mohamad S AlSalhi
- Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box -2455, Riyadh, 11451, Saudi Arabia.
| | - Vadivel Masilamani
- Masila's Cancer Diagnostics Private Limited, Madipakkam, Chennai, Tamil Nadu, 600091, India
| | - Fatmah Alqahtany
- Department of Pathology, Hematopathology Unit, College of Medicine, King Saud University, King Saud University Medical City, Riyadh, 11451, Saudi Arabia
| | - Aruliah Rajasekar
- Environmental Molecular Microbiology Research Laboratory, Department of Biotechnology, Thiruvalluvar University, Serkadu, Vellore, 632115, Tamil Nadu, India
| | - Ahmed Alenazi
- Department Clinical Laboratory Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, 11451, Saudi Arabia
| | - Karim Farhat
- Department of Urology, Cancer Research Chair, College of Medicine, King Saud University, Riyadh, 11451, Saudi Arabia
| |
Collapse
|
14
|
Sher M, Coleman B, Caputi M, Asghar W. Development of a Point-of-Care Assay for HIV-1 Viral Load Using Higher Refractive Index Antibody-Coated Microbeads. SENSORS 2021; 21:s21051819. [PMID: 33807789 PMCID: PMC7961362 DOI: 10.3390/s21051819] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 02/26/2021] [Accepted: 02/28/2021] [Indexed: 11/16/2022]
Abstract
The detection of viruses using imaging techniques is challenging because of the weak scattering of light generated by the targets of sizes in the nanometer range. The system we have developed overcomes the light scattering problems by utilizing antibody-coated microbeads of higher index of refraction that can specifically bind with viruses and increase the acceptance angle. Using the new technology, we have developed a portable, cost-effective, and field-deployable platform for the rapid quantification of HIV-1 viral load for point-of-care (POC) settings. The system combines microfluidics with a wide field of view lensless imaging technology. Highly specific antibodies are functionalized to a glass slide inside a microchip to capture HIV-1 virions. The captured virions are then bound by antibody-conjugated microbeads, which have a higher refraction index. The microbeads-HIV-1 virions complexes generate diffraction patterns that are detected with a custom-built imaging setup and rapidly and accurately quantified by computational analysis. This platform technology enables fast nanoscale virus imaging and quantification from biological samples and thus can play a significant role in the detection and management of viral diseases.
Collapse
Affiliation(s)
- Mazhar Sher
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA;
- Department of Computer & Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA
| | - Benjamin Coleman
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, TX 77005, USA;
| | - Massimo Caputi
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL 33431, USA;
| | - Waseem Asghar
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL 33431, USA;
- Department of Computer & Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA
- Department of Biological Sciences (Courtesy Appointment), Florida Atlantic University, Boca Raton, FL 33431, USA
- Correspondence:
| |
Collapse
|
15
|
Yang N, Peng J, Wu L, Han X, Shaheen N, Zou X. Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE-JTEHM 2021; 9:2800109. [PMID: 33552751 PMCID: PMC7861347 DOI: 10.1109/jtehm.2021.3054556] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 12/18/2020] [Accepted: 12/25/2020] [Indexed: 12/23/2022]
Abstract
BACKGROUND Vaginitis is a common and very private disease, and the current diagnosis is a frequent go to the hospital for testing. OBJECTIVE In order to improve the convenience and speed of detection, in this paper, we have developed a hand-held zoom micro-imaging system based on a microfluidic chip for point-of-care testing (POCT) of vaginal inflammation. METHODS This system consists of a microfluidic chip, an optical system and a hand-held zoom system assembled with a mobile phone. In terms of hardware, we designed a self-priming microfluidic chip, which can realize automatic sampling and full mixing of samples. We have also developed an optical system that can be adapted to smartphones, which has a lens group with a 37x magnification function and equipped with a zoom system with a focus range of 4mm to 6mm. In terms of software, we proposed an APP that can accurately identify cocci and can determine the inflammation level. RESULTS Compared with the recognition rate of the observers in the hospital, the detection accuracy of the portable recognition system is 95%, and after testing the clinical samples, the results were completely consistent with the hospital diagnosis results. The detection limit was 500 CFU / ml, which the relative error was (0.9 ± 0.3) %, and recognition time is 7 seconds. CONCLUSION This system is definitely suitable for women's point-of-care testing (POCT).
Collapse
Affiliation(s)
- Ning Yang
- Department of Electrical and Information EngineeringJiangsu UniversityZhenjiang212013China
| | - Jingxin Peng
- Department of Electrical and Information EngineeringJiangsu UniversityZhenjiang212013China
| | - Liang Wu
- Department of MedicineJiangsu UniversityZhenjiang212013China
| | - Xue Han
- Department of Electrical and Information EngineeringJiangsu UniversityZhenjiang212013China
| | - Naila Shaheen
- Department of Electrical and Information EngineeringJiangsu UniversityZhenjiang212013China
| | - Xiaobo Zou
- Department of Food and Biological EngineeringJiangsu UniversityZhenjiang212013China
| |
Collapse
|
16
|
Fennell RD, Sher M, Asghar W. Design, Development, and Performance Comparison of Wide Field Lensless and Lens-Based Optical Systems for Point-of-Care Biological Applications. OPTICS AND LASERS IN ENGINEERING 2021; 137:106326. [PMID: 32905530 PMCID: PMC7472995 DOI: 10.1016/j.optlaseng.2020.106326] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Lensless biological imaging systems are an emerging alternative to conventional microscopic systems because they enable a wide field of view imaging. While most microscopic systems sacrifice the field of view for magnification, lensless systems have taken advantage of small imaging pixel size, projection, digital magnification, and post-processing to compensate for diffracted images. A new lens-based system is designed to have the exact same wide field of view as that of a basic lensless setup. A new compound lens system design is utilized to achieve an explicit aim to have the same fields of view as the lensless setup. Then the characteristics of these two optical imaging setups (lensless and lens-based setups) are compared at this level of complexity to see what the minimal systems principles are needed to achieve the biological imaging goals for simplified and less expensive future designs. For both imaging systems, images of biological entities are recorded with the help of the same CMOS imaging device and computer software. The main contribution of this work is an exhaustive comparison between the performance characteristics of both systems using optical standards and biological images.
Collapse
Affiliation(s)
- Robert D. Fennell
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, Florida 33431
- Department of Computer & Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, Florida 33431
| | - Mazhar Sher
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, Florida 33431
- Department of Computer & Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, Florida 33431
| | - Waseem Asghar
- Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, Florida 33431
- Department of Computer & Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, Florida 33431
- Department of Biological Sciences (Courtesy Appointment), Florida Atlantic University, Boca Raton, FL 33431
- Corresponding author: Waseem Asghar ()
| |
Collapse
|
17
|
Chen L, Liu Y, Xu H, Ma L, Wang Y, Wang F, Zhu J, Hu X, Yi K, Yang Y, Shen H, Zhou F, Gao X, Cheng Y, Bai L, Duan Y, Wang F, Zhu Y. Touchable cell biophysics property recognition platforms enable multifunctional blood smart health care. MICROSYSTEMS & NANOENGINEERING 2021; 7:103. [PMID: 34963817 PMCID: PMC8651774 DOI: 10.1038/s41378-021-00329-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 10/25/2021] [Accepted: 11/06/2021] [Indexed: 05/10/2023]
Abstract
As a crucial biophysical property, red blood cell (RBC) deformability is pathologically altered in numerous disease states, and biochemical and structural changes occur over time in stored samples of otherwise normal RBCs. However, there is still a gap in applying it further to point-of-care blood devices due to the large external equipment (high-resolution microscope and microfluidic pump), associated operational difficulties, and professional analysis. Herein, we revolutionarily propose a smart optofluidic system to provide a differential diagnosis for blood testing via precise cell biophysics property recognition both mechanically and morphologically. Deformation of the RBC population is caused by pressing the hydrogel via an integrated mechanical transfer device. The biophysical properties of the cell population are obtained by the designed smartphone algorithm. Artificial intelligence-based modeling of cell biophysics properties related to blood diseases and quality was developed for online testing. We currently achieve 100% diagnostic accuracy for five typical clinical blood diseases (90 megaloblastic anemia, 78 myelofibrosis, 84 iron deficiency anemia, 48 thrombotic thrombocytopenic purpura, and 48 thalassemias) via real-world prospective implementation; furthermore, personalized blood quality (for transfusion in cardiac surgery) monitoring is achieved with an accuracy of 96.9%. This work suggests a potential basis for next-generation blood smart health care devices.
Collapse
Affiliation(s)
- Longfei Chen
- Affiliations School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan, 430072 China
- Shenzhen Research Institute, Wuhan University, Shenzhen, 518000 China
| | - Yantong Liu
- Affiliations School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan, 430072 China
- Shenzhen Research Institute, Wuhan University, Shenzhen, 518000 China
| | - Hongshan Xu
- Affiliations School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan, 430072 China
| | - Linlu Ma
- Department of Hematology, Zhongnan Hospital, Wuhan University, Wuhan, 430071 China
| | - Yifan Wang
- Affiliations School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan, 430072 China
| | - Fang Wang
- Affiliations School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan, 430072 China
| | - Jiaomeng Zhu
- Affiliations School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan, 430072 China
| | - Xuejia Hu
- Affiliations School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan, 430072 China
| | - Kezhen Yi
- Department of Laboratory Medicine, Zhongnan Hospital, Wuhan University, Wuhan, 430071 China
| | - Yi Yang
- Affiliations School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan, 430072 China
- Shenzhen Research Institute, Wuhan University, Shenzhen, 518000 China
| | - Hui Shen
- Department of Hematology, Zhongnan Hospital, Wuhan University, Wuhan, 430071 China
| | - Fuling Zhou
- Department of Hematology, Zhongnan Hospital, Wuhan University, Wuhan, 430071 China
| | - Xiaoqi Gao
- Affiliations School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan, 430072 China
| | - Yanxiang Cheng
- Remin Hospital of Wuhan University, Wuhan University, Wuhan, 430060 China
| | - Long Bai
- School of Medicine, Zhejiang University, Hangzhou, Zhejiang, 310002 China
| | - Yongwei Duan
- Department of Laboratory Medicine, Zhongnan Hospital, Wuhan University, Wuhan, 430071 China
| | - Fubing Wang
- Department of Laboratory Medicine, Zhongnan Hospital, Wuhan University, Wuhan, 430071 China
| | - Yimin Zhu
- School of Medicine, Zhejiang University, Hangzhou, Zhejiang, 310002 China
| |
Collapse
|
18
|
Chen W, Yao Y, Chen T, Shen W, Tang S, Lee HK. Application of smartphone-based spectroscopy to biosample analysis: A review. Biosens Bioelectron 2020; 172:112788. [PMID: 33157407 DOI: 10.1016/j.bios.2020.112788] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 10/05/2020] [Accepted: 10/30/2020] [Indexed: 12/18/2022]
Abstract
The emergence of the smartphones has brought extensive changes to our lifestyles, from communicating with one another, to shopping and enjoyment of entertainment, and from studying to functioning at the workplace (and in the field). At the same time, this portable device has also provided new possibilities in scientific research and applications. Based on the growing awareness of good health management, researchers have coupled health monitoring to smartphone sensing technologies. Along the way, there have been developed a variety of smartphone-based optical detection platforms for analyzing biological samples, including standalone smartphone units and integrated smartphone sensing systems. In this review, we outline the applications of smartphone-based optical sensors for biosamples. These applications focus mainly on three aspects: Microscopic imaging sensing, colorimetric sensing and luminescence sensing. We also discuss briefly some limitations of the current state of smartphone-based spectroscopy and present prospects of the future applicability of smartphone sensors.
Collapse
Affiliation(s)
- Wenhui Chen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Yao Yao
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Tianyu Chen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Wei Shen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Sheng Tang
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China.
| | - Hian Kee Lee
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore; National University of Singapore Environmental Research Institute, T-Lab Building #02-01, 5A Engineering Drive 1, Singapore, 117411, Singapore; Tropical Marine Science Institute, National University of Singapore, S2S Building, 18 Kent Ridge Road, Singapore, 119227, Singapore.
| |
Collapse
|