1
|
Fratus M, Alam MA. Theory of nanostructured sensors integrated in/on microneedles for diagnostics and therapy. Biosens Bioelectron 2024; 255:116238. [PMID: 38579625 DOI: 10.1016/j.bios.2024.116238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 03/05/2024] [Accepted: 03/21/2024] [Indexed: 04/07/2024]
Abstract
Efficient real-time diagnostics and on-demand drug delivery are essential components in modern healthcare, especially for managing chronic diseases. The lack of a rapid and effective sensing and therapeutic system can result in analyte level deviations, leading to severe complications. Minimally invasive microneedle (MN)-based patches integrating nanostructures (NSs) in their volume or on their surface have emerged as a biocompatible technology for delay-free analyte sensing and therapy. However, a quantitative relationship for the signal response in NS-assisted reactions remains elusive. Existing generalized formalisms are derived for in-vitro applications, raising questions about their direct applicability to in-situ wearable sensors. In this study, we apply the reaction-diffusion theory to establish a generalized physics-guided framework for NS-in-MN platforms in wearable applications. The model relates the signal response to analyte concentration, incorporating geometric, physical, and catalytic platform properties. Approximating the model under NS (binding or catalytic) and environmental (mass transport) limitations, we validate it against numerical simulations and various experimental results from diverse conditions - analyte sensing (glucose, lactic acid, pyocyanin, miRNA, etc.) in artificial and in-vivo environments (humans, mice, pigs, plants, etc.) through electrochemical and optical/colorimetric, enzymatic and non-enzymatic platforms. The results plotted in the scaled response show that (a) NS-limited platforms exhibit a linear dependence, (b) Mass transport-limited platforms saturate to 1, (c) a one-to-one mapping against traditional sensitivity plots unifies the scattered data points reported in literature. The universality of the model provides insightful perspectives for the design and optimization of MN-based sensing technologies, with potential extensions to dissolvable MNs as part of analyte-responsive closed-loop therapeutic applications.
Collapse
Affiliation(s)
- Marco Fratus
- Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, 47906, Indiana, USA.
| | - Muhammad A Alam
- Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, 47906, Indiana, USA.
| |
Collapse
|
2
|
Fratus M, Alam MA. Performance gain and electro-mechanical design optimization of microneedles for wearable sensor systems. Biomed Microdevices 2023; 26:4. [PMID: 38095755 DOI: 10.1007/s10544-023-00683-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/15/2023] [Indexed: 12/18/2023]
Abstract
Minimally invasive microneedle (MN) is an emerging technology platform for wearable and implantable diagnostics and therapeutics systems. These short MNs offer pain-free insertion and simple operation. Among the MN technologies proposed to enhance interstitial fluid (ISF) extraction, porous and swellable (P-S) hydrogels absorb analyte molecules across the entire lateral surface. Currently, the design, development, and optimization of the MNs rely on empirical, iterative approaches. Based on theory of fluid flow and analyte diffusion through geometrically complex biomimetic systems, here we derive a generalized physics-guided model for P-S MN sensors. The framework (a) quantifies MN extracting efficiency [Formula: see text] in terms of its geometric and physical properties, and (b) suggests strategies to optimize sensor response while satisfying the mechanical constraints related to various skin-types (e.g., mouse, pig, humans, etc.). Our results show that, despite the differences in geometry and composition, P-S MNs obey a universal scaling response, [Formula: see text] with [Formula: see text] being MN length, diffusivity, and radius, respectively, and [Formula: see text], [Formula: see text] and [Formula: see text] are the ratio between approximate vs. exact analytical solutions, the effective biofluid transfer coefficient between dermis and skin, and the exponent for the power-law approximation, respectively. These parameters quantify the biomolecule transfer through the dermis-to-MN interface at different scaling limits. P-S MNs outperform hollow MNs by a 2-6x enhancement factor; however, the buckling-limit of insertion defines the maximized functionality of the sensor. Our model, validated against experimental results and numerical simulations, offers a predictive design framework to significantly reduce the optimization time for P-S MN-based sensor platforms.
Collapse
Affiliation(s)
- Marco Fratus
- Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, 47906, Indiana, USA.
| | - Muhammad Ashraful Alam
- Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, 47906, Indiana, USA
| |
Collapse
|
3
|
Dai Y, Nolan J, Madsen E, Fratus M, Lee J, Zhang J, Lim J, Hong S, Alam MA, Linnes JC, Lee H, Lee CH. Wearable Sensor Patch with Hydrogel Microneedles for In Situ Analysis of Interstitial Fluid. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 38041570 DOI: 10.1021/acsami.3c12740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2023]
Abstract
Continuous real-time monitoring of biomarkers in interstitial fluid is essential for tracking metabolic changes and facilitating the early detection and management of chronic diseases such as diabetes. However, developing minimally invasive sensors for the in situ analysis of interstitial fluid and addressing signal delays remain a challenge. Here, we introduce a wearable sensor patch incorporating hydrogel microneedles for rapid, minimally invasive collection of interstitial fluid from the skin while simultaneously measuring biomarker levels in situ. The sensor patch is stretchable to accommodate the swelling of the hydrogel microneedles upon extracting interstitial fluid and adapts to skin deformation during measurements, ensuring consistent sensing performance in detecting model biomarker concentrations, such as glucose and lactate, in a mouse model. The sensor patch exhibits in vitro sensitivities of 0.024 ± 0.002 μA mM-1 for glucose and 0.0030 ± 0.0004 μA mM-1 for lactate, with corresponding linear ranges of 0.1-3 and 0.1-12 mM, respectively. For in vivo glucose sensing, the sensor patch demonstrates a sensitivity of 0.020 ± 0.001 μA mM-1 and a detection range of 1-8 mM. By integrating a predictive model, the sensor patch can analyze and compensate for signal delays, improving calibration reliability and providing guidance for potential optimization in sensing performance. The sensor patch is expected to serve as a minimally invasive platform for the in situ analysis of multiple biomarkers in interstitial fluid, offering a promising solution for continuous health monitoring and disease management.
Collapse
Affiliation(s)
- Yumin Dai
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - James Nolan
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Emilee Madsen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Marco Fratus
- Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Junsang Lee
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Jinyuan Zhang
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Jongcheon Lim
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Seokkyoon Hong
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Muhammad A Alam
- Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Jacqueline C Linnes
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Department of Public Health, Purdue University, West Lafayette, Indiana 47907, United States
| | - Hyowon Lee
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Center for Implantable Devices, Purdue University, West Lafayette, Indiana 47907, United States
| | - Chi Hwan Lee
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Center for Implantable Devices, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
4
|
Nithianandam P, Tzu-li L, Chen S, Yizhen J, Dong Y, Saul M, Tedeschi A, Wenjing S, Jinghua L. Flexible, Miniaturized Sensing Probes Inspired by Biofuel Cells for Monitoring Synaptically Released Glutamate in the Mouse Brain. Angew Chem Int Ed Engl 2023; 62:e202310245. [PMID: 37632702 PMCID: PMC10592105 DOI: 10.1002/anie.202310245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 08/20/2023] [Accepted: 08/24/2023] [Indexed: 08/28/2023]
Abstract
Chemical biomarkers in the central nervous system can provide valuable quantitative measures to gain insight into the etiology and pathogenesis of neurological diseases. Glutamate, one of the most important excitatory neurotransmitters in the brain, has been found to be upregulated in various neurological disorders, such as traumatic brain injury, Alzheimer's disease, stroke, epilepsy, chronic pain, and migraines. However, quantitatively monitoring glutamate release in situ has been challenging. This work presents a novel class of flexible, miniaturized probes inspired by biofuel cells for monitoring synaptically released glutamate in the nervous system. The resulting sensors, with dimensions as low as 50 by 50 μm, can detect real-time changes in glutamate within the biologically relevant concentration range. Experiments exploiting the hippocampal circuit in mice models demonstrate the capability of the sensors in monitoring glutamate release via electrical stimulation using acute brain slices. These advances could aid in basic neuroscience studies and translational engineering, as the sensors provide a diagnostic tool for neurological disorders. Additionally, adapting the biofuel cell design to other neurotransmitters can potentially enable the detailed study of the effect of neurotransmitter dysregulation on neuronal cell signaling pathways and revolutionize neuroscience.
Collapse
Affiliation(s)
- Prasad Nithianandam
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Liu Tzu-li
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Shulin Chen
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Jia Yizhen
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Yan Dong
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Morgan Saul
- Department of Neuroscience, The Ohio State University College of Medicine, The Ohio State University, Columbus, OH 43210, USA
| | - Andrea Tedeschi
- Department of Neuroscience, The Ohio State University College of Medicine, Chronic Brain Injury Program, The Ohio State University, Columbus, OH 43210, USA
| | - Sun Wenjing
- Department of Neuroscience, The Ohio State University College of Medicine, Columbus, OH 43210, USA
| | - Li Jinghua
- Department of Materials Science and Engineering, Chronic Brain Injury Program, The Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
5
|
Luo X, Luo Z, Li S, Fang Q, Xu W, Wang H, Wang Y, Bao GM, Gu W, Zhu C. Nanozymatic Biofuel Cell-Enabled Self-Powered Sensing System for a Sensitive Immunoassay. Anal Chem 2023; 95:12306-12312. [PMID: 37556591 DOI: 10.1021/acs.analchem.3c01576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/11/2023]
Abstract
Self-powered sensing system (SPSS) integrating the enzymatic biofuel cell and biosensing platform has attracted tremendous interest. However, natural enzymes suffer from the intrinsic drawbacks of enzymes and enzymatic proteins. Nanozymes with enzyme-like activities are the ideal alternatives to enzymes, and it is greatly challenging to explore high-performance nanozymatic biofuel cell for SPSS. Herein, the advanced nanozymatic biofuel cell-enabled SPSS is developed for the sensitive detection of the prostate-specific antigen (PSA), where Ir single atoms supported by nitrogen-doped carbon and Au nanozymes serve as the cathode and anode, respectively. Based on the excellent electrochemical activity and stability, the resultant nanozymatic biofuel cell exhibits a higher power output and open-circuit potential than the Pt/C-based counterpart, which is beneficial for the application of SPSS. As a proof of concept, the nanozymatic biofuel cell-enabled SPSS shows a wide detection range of 0.2-500 ng mL-1 with a detection limit of 62 pg mL-1 for PSA, which provides new insight into broadening the application scenarios of nanozymes.
Collapse
Affiliation(s)
- Xin Luo
- Hubei Provincial Cooperative Innovation Center of Industrial Fermentation, Key Laboratory of Fermentation Engineering (Ministry of Education), National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Hubei Research Center of Food Fermentation Engineering and Technology, Hubei University of Technology, Wuhan 430068, P. R. China
| | - Zhen Luo
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079, P. R. China
| | - Shentian Li
- Hubei Provincial Cooperative Innovation Center of Industrial Fermentation, Key Laboratory of Fermentation Engineering (Ministry of Education), National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Hubei Research Center of Food Fermentation Engineering and Technology, Hubei University of Technology, Wuhan 430068, P. R. China
| | - Qie Fang
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079, P. R. China
| | - Weiqing Xu
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079, P. R. China
| | - Hengjia Wang
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079, P. R. China
| | - Yongze Wang
- Hubei Provincial Cooperative Innovation Center of Industrial Fermentation, Key Laboratory of Fermentation Engineering (Ministry of Education), National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Hubei Research Center of Food Fermentation Engineering and Technology, Hubei University of Technology, Wuhan 430068, P. R. China
| | - Guang-Ming Bao
- Hubei Provincial Cooperative Innovation Center of Industrial Fermentation, Key Laboratory of Fermentation Engineering (Ministry of Education), National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Hubei Research Center of Food Fermentation Engineering and Technology, Hubei University of Technology, Wuhan 430068, P. R. China
| | - Wenling Gu
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079, P. R. China
| | - Chengzhou Zhu
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079, P. R. China
| |
Collapse
|
6
|
Shi J, Xie WZ, Wang LR, Song YL, Lin Y, Wu Y, Luo H, Huang KJ, Tan X. All-carbon sandwich-type self-powered biosensor for ultrasensitive detection of femtomolar miRNA-141. Anal Chim Acta 2022; 1236:340589. [DOI: 10.1016/j.aca.2022.340589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 10/29/2022] [Accepted: 11/02/2022] [Indexed: 11/06/2022]
|
7
|
Resettable sweat-powered wearable electrochromic biosensor. Biosens Bioelectron 2022; 215:114565. [DOI: 10.1016/j.bios.2022.114565] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 07/06/2022] [Accepted: 07/08/2022] [Indexed: 12/15/2022]
|
8
|
Liu TL, Dong Y, Chen S, Zhou J, Ma Z, Li J. Battery-free, tuning circuit-inspired wireless sensor systems for detection of multiple biomarkers in bodily fluids. SCIENCE ADVANCES 2022; 8:eabo7049. [PMID: 35857473 PMCID: PMC9258955 DOI: 10.1126/sciadv.abo7049] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 05/23/2022] [Indexed: 06/15/2023]
Abstract
Tracking the concentration of biomarkers in biofluids can provide crucial information about health status. However, the complexity and nonideal form factors of conventional digital wireless schemes impose challenges in realizing biointegrated, lightweight, and miniaturized sensors. Inspired by the working principle of tuning circuits in radio frequency electronics, this study reports a class of battery-free wireless biochemical sensors: In a resonance circuit, the coupling between a sensing interface and an inductor-capacitor oscillator through a pair of varactor diodes converts a change in electric potential into a modulation in capacitance, resulting in a quantifiable shift of the resonance circuit. Proper design of sensing interfaces with biorecognition elements enables the detection of various biomarkers, including ions, neurotransmitters, and metabolites. Demonstrations of "smart accessories" and miniaturized probes suggest the broad utility of this circuit model. The design concepts and sensing strategies provide a realistic pathway to building biointegrated electronics for wireless biochemical sensing.
Collapse
Affiliation(s)
- Tzu-Li Liu
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43220, USA
| | - Yan Dong
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43220, USA
| | - Shulin Chen
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43220, USA
| | - Jie Zhou
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Zhenqiang Ma
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
- Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
- Department of Engineering Physics, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Jinghua Li
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43220, USA
- Chronic Brain Injury Program, The Ohio State University, Columbus, OH 43220, USA
| |
Collapse
|
9
|
Immobilizing Enzymes on a Commercial Polymer: Performance Analysis of a GOx-Laccase Based Enzymatic Biofuel Cell Assembly. ENERGIES 2022. [DOI: 10.3390/en15062182] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Enzymatic Biofuel Cell (EBC) represents a promising green source since it is capable of harvesting electricity from renewable and abundantly available biofuels using enzymes as catalysts. Nevertheless, nowadays long-term stability and low power output are currently the main concerns. To this end, several research studies focus on using complex tridimensional and highly expensive nanostructures as electrode support for enzymes. This increases cell performance whilst drastically reducing the economic feasibility needed for industrial viability. Thus, this paper analyzes a novel flow-based EBC consisting of covalent immobilized GOx (bioanode) and Laccase (biocathode) on a commercial flat conductive polymer. A suitable immobilization technique based on covalent ligands is carried out to enhance EBC durability. The experimental characterization demonstrates that the cell generates power over three weeks, reaching 590 mV and 2.41 µW cm−2 as maximum open circuit voltage and power density, respectively. The most significant contributions of this configuration are definitely ease of implementation, low cost, high scalability, and reproducibility. Therefore, such a design can be considered a step forward in the viable EBC industrialization process for a wide range of applications.
Collapse
|
10
|
Manjakkal L, Yin L, Nathan A, Wang J, Dahiya R. Energy Autonomous Sweat-Based Wearable Systems. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2100899. [PMID: 34247412 DOI: 10.1002/adma.202100899] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 03/03/2021] [Indexed: 05/05/2023]
Abstract
The continuous operation of wearable electronics demands reliable sources of energy, currently met through Li-ion batteries and various energy harvesters. These solutions are being used out of necessity despite potential safety issues and unsustainable environmental impact. Safe and sustainable energy sources can boost the use of wearables systems in diverse applications such as health monitoring, prosthetics, and sports. In this regard, sweat- and sweat-equivalent-based studies have attracted tremendous attention through the demonstration of energy-generating biofuel cells, promising power densities as high as 3.5 mW cm-2 , storage using sweat-electrolyte-based supercapacitors with energy and power densities of 1.36 Wh kg-1 and 329.70 W kg-1 , respectively, and sweat-activated batteries with an impressive energy density of 67 Ah kg-1 . A combination of these energy generating, and storage devices can lead to fully energy-autonomous wearables capable of providing sustainable power in the µW to mW range, which is sufficient to operate both sensing and communication devices. Here, a comprehensive review covering these advances, addressing future challenges and potential solutions related to fully energy-autonomous wearables is presented, with emphasis on sweat-based energy storage and energy generation elements along with sweat-based sensors as applications.
Collapse
Affiliation(s)
- Libu Manjakkal
- Bendable Electronics and Sensing Technologies (BEST) Group, James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Lu Yin
- Department of Nanoengineering, Centre of Wearable Sensors, University of California, San Diego, CA, 92093, USA
| | - Arokia Nathan
- Darwin College, University of Cambridge, Silver Street, Cambridge, CB3 9EU, UK
| | - Joseph Wang
- Department of Nanoengineering, Centre of Wearable Sensors, University of California, San Diego, CA, 92093, USA
| | - Ravinder Dahiya
- Bendable Electronics and Sensing Technologies (BEST) Group, James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK
| |
Collapse
|
11
|
Ghaffari R, Yang DS, Kim J, Mansour A, Wright JA, Model JB, Wright DE, Rogers JA, Ray TR. State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics. ACS Sens 2021; 6:2787-2801. [PMID: 34351759 DOI: 10.1021/acssensors.1c01133] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Skin-interfaced wearable systems with integrated colorimetric assays, microfluidic channels, and electrochemical sensors offer powerful capabilities for noninvasive, real-time sweat analysis. This Perspective details recent progress in the development and translation of novel wearable sensors for personalized assessment of sweat dynamics and biomarkers, with precise sampling and real-time analysis. Sensor accuracy, system ruggedness, and large-scale deployment in remote environments represent key opportunity areas, enabling broad deployment in the context of field studies, clinical trials, and recent commercialization. On-body measurements in these contexts show good agreement compared to conventional laboratory-based sweat analysis approaches. These device demonstrations highlight the utility of biochemical sensing platforms for personalized assessment of performance, wellness, and health across a broad range of applications.
Collapse
Affiliation(s)
- Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Da Som Yang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Joohee Kim
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Amer Mansour
- Division of Biological Sciences, The University of Chicago, Chicago, Illinois 60637, United States
| | - John A. Wright
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Jeffrey B. Model
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Donald E. Wright
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - John A. Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
- Departments of Materials Science and Engineering, Mechanical Engineering, Electrical and Computer Engineering, and Chemistry, Northwestern University, Evanston, Illinois 60202, United States
- Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois 60611, United States
| | - Tyler R. Ray
- Department of Mechanical Engineering, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96822, United States
- Department of Cell and Molecular Biology, John A. Burns School of Medicine, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96813, United States
| |
Collapse
|
12
|
Gonzalez-Solino C, Bernalte E, Bayona Royo C, Bennett R, Leech D, Di Lorenzo M. Self-Powered Detection of Glucose by Enzymatic Glucose/Oxygen Fuel Cells on Printed Circuit Boards. ACS APPLIED MATERIALS & INTERFACES 2021; 13:26704-26711. [PMID: 34038080 PMCID: PMC8735749 DOI: 10.1021/acsami.1c02747] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 05/12/2021] [Indexed: 05/31/2023]
Abstract
Monitoring glucose levels in physiological fluids can help prevent severe complications associated with hypo- and hyper-glycemic events. Current glucose-monitoring systems require a three-electrode setup and a power source to function, which can hamper the system miniaturization to the patient discomfort. Enzymatic fuel cells (EFCs) offer the opportunity to develop self-powered and minimally invasive glucose sensors by eliminating the need for an external power source. Nevertheless, practical applications demand for cost-effective and mass-manufacturable EFCs compatible with integration strategies. In this study, we explore for the first time the use of gold electrodes on a printed circuit board (PCB) for the development of an EFC and demonstrate its application in saliva. To increase the specific surface area, the PCB gold-plated electrodes were modified with porous gold films. At the anode, glucose oxidase is immobilized with an osmium redox polymer that serves as an electron-transfer mediator. At the cathode, bilirubin oxidase is adsorbed onto the porous gold surface with a blocking agent that prevents parasitic reactions while maintaining the enzyme catalytic activity. The resulting EFC showed a linear response to glucose in phosphate buffer within the range 50 μM to 1 mM, with a sensitivity of 14.13 μA cm-2 mM-1. The sensor was further characterized in saliva, showing the linear range of detection of 0.75 to 2 mM, which is within the physiological range, and sensitivity of 21.5 μA cm-2 mM-1. Overall, this work demonstrates that PCBs are suitable platforms for EFCs, paving the way for the development of fully integrated systems in a seamless and miniaturized device.
Collapse
Affiliation(s)
- Carla Gonzalez-Solino
- Department
of Chemical Engineering, University of Bath, Bath BA2 7AY, U.K.
- Centre
for Biosensors, Bioelectronics and Biodevices (C3Bio), University of Bath, Bath BA2 7AY, U.K.
| | - Elena Bernalte
- Department
of Chemical Engineering, University of Bath, Bath BA2 7AY, U.K.
- Centre
for Biosensors, Bioelectronics and Biodevices (C3Bio), University of Bath, Bath BA2 7AY, U.K.
| | - Clara Bayona Royo
- Department
of Chemical Engineering, University of Bath, Bath BA2 7AY, U.K.
- Centre
for Biosensors, Bioelectronics and Biodevices (C3Bio), University of Bath, Bath BA2 7AY, U.K.
| | - Richard Bennett
- School
of Chemistry & Ryan Institute, National
University of Ireland Galway, University Road, Galway H91 TK33, Ireland
| | - Dónal Leech
- School
of Chemistry & Ryan Institute, National
University of Ireland Galway, University Road, Galway H91 TK33, Ireland
| | - Mirella Di Lorenzo
- Department
of Chemical Engineering, University of Bath, Bath BA2 7AY, U.K.
- Centre
for Biosensors, Bioelectronics and Biodevices (C3Bio), University of Bath, Bath BA2 7AY, U.K.
| |
Collapse
|
13
|
Santiago-Malagón S, Río-Colín D, Azizkhani H, Aller-Pellitero M, Guirado G, Del Campo FJ. A self-powered skin-patch electrochromic biosensor. Biosens Bioelectron 2021; 175:112879. [PMID: 33309218 DOI: 10.1016/j.bios.2020.112879] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 11/28/2020] [Accepted: 12/01/2020] [Indexed: 01/12/2023]
Abstract
One of the limitations of many skin-patch wearable sensors today is their dependence on silicon-based electronics, increasing their complexity and unit cost. Self-powered sensors, in combination with electrochromic materials, allow simplifying the construction of these devices, leading to powerful analytical tools that remove the need for external detection systems. This work describes the construction, by screen-printing, of a self-powered electrochromic device that can be adapted for the determination of metabolites in sweat by the naked eye in the form of a 3 × 15 mm colour bar. The device comprises a lactate oxidase and osmium-polymer -based anode connected to a coplanar 3 × 15 mm Prussian Blue, PB, cathode printed over a transparent poly(3,4-ethylenedioxythiophene) polystyrene sulfonate, PEDOT:PSS electrode. An ion-gel composed of Poly(vinylidene fluoride-co-hexafluoropropylene), PVDF-co-HFP, a gelling agent, and ionic liquid 1-Ethyl-3-methylimidazolium trifluoromethanesulfonate, EMIM-Tf, effectively separates the cathode display from the biosensing anode, protecting it from the sample. Despite its cathodic electrochromism, the PEDOT:PSS has a transmission above 90% and does not mask the Prussian Blue colour change because the cathode does not operate below 0 V vs Ag/AgCl at any time. The sensor displays lactate concentrations in the range of 0-10 mM over the length of the electrochromic display, which has a contrast ratio of 1.43. Although full response takes up to 24 min, 85% of the colour change is displayed within 10 min.
Collapse
Affiliation(s)
| | - Diego Río-Colín
- Universidad Del País Vasco, UPV-EHU, Campus de Leioa, Vizcaya, Spain
| | | | - Miguel Aller-Pellitero
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus de la Universitat Autónoma de Barcelona, Esfera UAB, 08193, Bellaterra, Barcelona, Spain; Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | | | - F Javier Del Campo
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus de la Universitat Autónoma de Barcelona, Esfera UAB, 08193, Bellaterra, Barcelona, Spain; BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940, Leioa, Spain; IKERBASQUE, Basque Foundation for Science, 48009, Bilbao, Spain.
| |
Collapse
|