1
|
Su H, Yan J, Yan X, Zhao Q, Liao C, Li N, Wang X. Highly sensitive standardized toxicity biosensors for rapid water quality warning. BIORESOURCE TECHNOLOGY 2024; 406:130985. [PMID: 38885731 DOI: 10.1016/j.biortech.2024.130985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 06/14/2024] [Accepted: 06/14/2024] [Indexed: 06/20/2024]
Abstract
Microbial electrochemical sensor (MES) using electroactive biofilm (EAB) as the sensing element represents a broad-spectrum technology for early warning of biotoxicity of water samples. However, its commercial application is impeded by limited sensitivity and repeatability. Here, we proposed a layered standardized EAB (SEAB) with enriched Geobacter anodireducens SD-1 in the inner layer and self-matched outer layer. The SEAB sensors showed a 2.3 times higher sensitivity than conventional EAB acclimated directly from wastewater (WEAB). A highly repeatable response sensitivity was concentrated at 0.011 ± 0.0006 A/m2/ppm in 4 replicated batches of SEAB sensors (R2 > 0.95), highlighting their potential for reliable toxicity monitoring in practical applications. In contrast, the sensing performance of all WEAB sensors was unpredictable. SEAB also exhibited a better tolerance towards low concentration of formaldehyde, with only a 4 % loss in viability. Our findings improved the sensitivity and reproducibility of standardized MES for toxicity early warning.
Collapse
Affiliation(s)
- Huijuan Su
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Jiaguo Yan
- Oilfield Chemicals Division, China Oilfield Services Limited (COSL), Tianjin Marine Petroleum Environmental and Reservoir Low-Damage Drilling Fluid Enterprise Key Laboratory, China.
| | - Xuejun Yan
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Qian Zhao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Nan Li
- School of Environmental Science and Engineering, Tianjin University, No. 35 Yaguan Road, Jinnan District, Tianjin 300350, China
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China.
| |
Collapse
|
2
|
Perchikov R, Cheliukanov M, Plekhanova Y, Tarasov S, Kharkova A, Butusov D, Arlyapov V, Nakamura H, Reshetilov A. Microbial Biofilms: Features of Formation and Potential for Use in Bioelectrochemical Devices. BIOSENSORS 2024; 14:302. [PMID: 38920606 PMCID: PMC11201457 DOI: 10.3390/bios14060302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 06/03/2024] [Accepted: 06/05/2024] [Indexed: 06/27/2024]
Abstract
Microbial biofilms present one of the most widespread forms of life on Earth. The formation of microbial communities on various surfaces presents a major challenge in a variety of fields, including medicine, the food industry, shipping, etc. At the same time, this process can also be used for the benefit of humans-in bioremediation, wastewater treatment, and various biotechnological processes. The main direction of using electroactive microbial biofilms is their incorporation into the composition of biosensor and biofuel cells This review examines the fundamental knowledge acquired about the structure and formation of biofilms, the properties they have when used in bioelectrochemical devices, and the characteristics of the formation of these structures on different surfaces. Special attention is given to the potential of applying the latest advances in genetic engineering in order to improve the performance of microbial biofilm-based devices and to regulate the processes that take place within them. Finally, we highlight possible ways of dealing with the drawbacks of using biofilms in the creation of highly efficient biosensors and biofuel cells.
Collapse
Affiliation(s)
- Roman Perchikov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Maxim Cheliukanov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Yulia Plekhanova
- Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia; (Y.P.); (S.T.)
| | - Sergei Tarasov
- Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia; (Y.P.); (S.T.)
| | - Anna Kharkova
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Denis Butusov
- Computer-Aided Design Department, Saint Petersburg Electrotechnical University “LETI”, Saint Petersburg 197022, Russia;
| | - Vyacheslav Arlyapov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Hideaki Nakamura
- Department of Liberal Arts, Tokyo University of Technology, 1404-1 Katakura, Hachioji 192-0982, Tokyo, Japan;
| | - Anatoly Reshetilov
- Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia; (Y.P.); (S.T.)
| |
Collapse
|
3
|
Kharkova A, Perchikov R, Kurbanalieva S, Osina K, Popova N, Machulin A, Kamanina O, Saverina E, Saltanov I, Melenkov S, Butusov D, Arlyapov V. Targeted Formation of Biofilms on the Surface of Graphite Electrodes as an Effective Approach to the Development of Biosensors for Early Warning Systems. BIOSENSORS 2024; 14:239. [PMID: 38785713 PMCID: PMC11118945 DOI: 10.3390/bios14050239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 04/30/2024] [Accepted: 05/01/2024] [Indexed: 05/25/2024]
Abstract
Biofilms based on bacteria Pseudomonas veronii (Ps. veronii) and Escherichia coli (E. coli) and yeast Saccharomyces cerevisiae (S. cerevisiae) were used for novel biosensor creation for rapid biochemical oxygen demand (BOD) monitoring. Based on the electrochemical measurement results, it was shown that the endogenous mediator in the matrix of E. coli and Ps. veronii biofilms and ferrocene form a two-mediator system that improves electron transport in the system. Biofilms based on Ps. veronii and E. coli had a high biotechnological potential for BOD assessment; bioreceptors based on such biofilms had high sensitivity (the lower limits of detectable BOD5 concentrations were 0.61 (Ps. veronii) and 0.87 (E. coli) mg/dm3) and high efficiency of analysis (a measurement time 5-10 min). The maximum biosensor response based on bacterial biofilms has been observed in the pH range of 6.6-7.2. The greatest protective effect was found for biofilms based on E. coli, which has high long-term stability (151 days for Ps. veronii and 163 days for E. coli). The results of the BOD5 analysis of water samples obtained using the developed biosensors had a high correlation with the results of the standard 5-day method (R2 = 0.9820, number of tested samples is 10 for Ps. veronii, and R2 = 0.9862, number of tested samples is 10 for E. coli). Thus, biosensors based on Ps. veronii biofilms and E. coli biofilms could be a novel analytical system to give early warnings of pollution.
Collapse
Affiliation(s)
- Anna Kharkova
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, 300012 Tula, Russia; (A.K.); (R.P.); (K.O.); (O.K.)
| | - Roman Perchikov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, 300012 Tula, Russia; (A.K.); (R.P.); (K.O.); (O.K.)
| | - Saniyat Kurbanalieva
- N. D. Zelinsky Institute of Organic Chemistry, 119991 Moscow, Russia; (S.K.); (E.S.)
| | - Kristina Osina
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, 300012 Tula, Russia; (A.K.); (R.P.); (K.O.); (O.K.)
| | - Nadezhda Popova
- Federal State Budgetary Institution of Science Institute of Physical Chemistry and Electrochemistry of the Russian Academy of Sciences, 119071 Moscow, Russia;
| | - Andrey Machulin
- Institute of Biochemistry and Physiology of Microorganisms of the Russian Academy of Sciences—A Separate Subdivision of the FRC Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences, 142290 Pushchino, Russia;
| | - Olga Kamanina
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, 300012 Tula, Russia; (A.K.); (R.P.); (K.O.); (O.K.)
| | - Evgeniya Saverina
- N. D. Zelinsky Institute of Organic Chemistry, 119991 Moscow, Russia; (S.K.); (E.S.)
| | - Ivan Saltanov
- Limited Liability Company “INNOBIOSYSTEMS”, 117342 Moscow, Russia; (I.S.); (S.M.)
| | - Sergey Melenkov
- Limited Liability Company “INNOBIOSYSTEMS”, 117342 Moscow, Russia; (I.S.); (S.M.)
| | - Denis Butusov
- Computer-Aided Design Department, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia;
| | - Vyacheslav Arlyapov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, 300012 Tula, Russia; (A.K.); (R.P.); (K.O.); (O.K.)
| |
Collapse
|
4
|
Zhao H, Zang Y, Xie B, Zhao T, Cao B, Wu J, Ge Y, Yi Y, Liu H. Instant water toxicity detection based on magnetically-constructed electrochemically active biofilm. Biosens Bioelectron 2023; 242:115745. [PMID: 37832348 DOI: 10.1016/j.bios.2023.115745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Revised: 09/30/2023] [Accepted: 10/06/2023] [Indexed: 10/15/2023]
Abstract
Water toxicity determination with electrochemically active bacteria (EAB) is promising in the early warning of water pollution. However, limited by tedious biofilm formation, natural EAB biofilms are uncapable of the instant detection of water toxicity, resulting in the failure for the emergency monitoring of water pollution. To solve this problem, a novel method for the rapid construction of EAB biofilms using magnetic adsorption was established, and the performance of instant water toxicity detection with magnetically-constructed EAB biofilm was investigated. The results demonstrate that EAB biofilms were magnetically constructed in less than 30 min, and magnetically-constructed EAB biofilm generated stable currents even under continuous flow conditions. Magnetically-constructed EAB biofilms realized instant water toxicity detection, and the sensitivity increased with the decrease of magnetic field intensity. Low magnetic field intensity resulted in a loose biofilm structure, which is conducive to toxic pollutant penetration. The detection limit for Cu2+, phenol, and Cd2+ achieved 0.07 mg/L with optimal magnetic field intensity, and the detection time was less than 30 min. This study broadens the application of water toxicity determination with EAB, and establishes a foundation for the instant and continuous detection of water toxicity with EAB.
Collapse
Affiliation(s)
- Hongyu Zhao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Yuxuan Zang
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Beizhen Xie
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Ting Zhao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Bo Cao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Jing Wu
- Medical and Health Analysis Center, Peking University, Beijing, 100191, China
| | - Yanhong Ge
- Infore Environment Technology Group, Foshan, 528000, Guangdong Province, China
| | - Yue Yi
- School of Life, Beijing Institute of Technology, 100081, China.
| | - Hong Liu
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China.
| |
Collapse
|
5
|
Aiyer K, Mukherjee D, Doyle LE. A Weak Electricigen-Based Bioelectrochemical Sensor for Real-Time Monitoring of Chemical Pollutants in Water. ACS APPLIED BIO MATERIALS 2023; 6:4105-4110. [PMID: 37718488 DOI: 10.1021/acsabm.3c00601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/19/2023]
Abstract
Electroactive microorganisms are now understood to be abundant across nature, though many are categorized as "weak electricigens" not suitable for reasonable power generation. We report the use of weak electricigens from the natural environment for rapid, real-time water quality monitoring. Using a variety of pesticides as model chemical pollutants, the bioelectrochemical sensor was responsive within minutes at all concentrations tested (0.05-2 ppm) and could be repreatedly used long-term. Due to the prevalence of electroactive microorganisms in the natural environment, such sensors could work in tandem with conventional monitoring methods and may be useful for detecting emerging contaminants.
Collapse
Affiliation(s)
- Kartik Aiyer
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, New Delhi 110016, India
- Center for Electromicrobiology, Aarhus University, Aarhus 8000, Denmark
| | - Debasa Mukherjee
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, New Delhi 110016, India
| | - Lucinda E Doyle
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, New Delhi 110016, India
| |
Collapse
|
6
|
Kuznetsova LS, Arlyapov VA, Plekhanova YV, Tarasov SE, Kharkova AS, Saverina EA, Reshetilov AN. Conductive Polymers and Their Nanocomposites: Application Features in Biosensors and Biofuel Cells. Polymers (Basel) 2023; 15:3783. [PMID: 37765637 PMCID: PMC10536614 DOI: 10.3390/polym15183783] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 09/10/2023] [Accepted: 09/13/2023] [Indexed: 09/29/2023] Open
Abstract
Conductive polymers and their composites are excellent materials for coupling biological materials and electrodes in bioelectrochemical systems. It is assumed that their relevance and introduction to the field of bioelectrochemical devices will only grow due to their tunable conductivity, easy modification, and biocompatibility. This review analyzes the main trends and trends in the development of the methodology for the application of conductive polymers and their use in biosensors and biofuel elements, as well as describes their future prospects. Approaches to the synthesis of such materials and the peculiarities of obtaining their nanocomposites are presented. Special emphasis is placed on the features of the interfaces of such materials with biological objects.
Collapse
Affiliation(s)
- Lyubov S. Kuznetsova
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, 300012 Tula, Russia
| | - Vyacheslav A. Arlyapov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, 300012 Tula, Russia
| | - Yulia V. Plekhanova
- Federal Research Center «Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences», G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia
| | - Sergei E. Tarasov
- Federal Research Center «Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences», G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia
| | - Anna S. Kharkova
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, 300012 Tula, Russia
| | - Evgeniya A. Saverina
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, 300012 Tula, Russia
- Federal State Budgetary Institution of Science, N.D. Zelinsky Institute of Organic Chemistry, 119991 Moscow, Russia
| | - Anatoly N. Reshetilov
- Federal Research Center «Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences», G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia
| |
Collapse
|
7
|
Medvedeva AS, Dyakova EI, Kuznetsova LS, Mironov VG, Gurkin GK, Rogova TV, Kharkova AS, Melnikov PV, Naumova AO, Butusov DN, Arlyapov VA. A Two-Mediator System Based on a Nanocomposite of Redox-Active Polymer Poly(thionine) and SWCNT as an Effective Electron Carrier for Eukaryotic Microorganisms in Biosensor Analyzers. Polymers (Basel) 2023; 15:3335. [PMID: 37631392 PMCID: PMC10459408 DOI: 10.3390/polym15163335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 08/03/2023] [Accepted: 08/04/2023] [Indexed: 08/27/2023] Open
Abstract
Electropolymerized thionine was used as a redox-active polymer to create a two-mediated microbial biosensor for determining biochemical oxygen demand (BOD). The electrochemical characteristics of the conducting system were studied by cyclic voltammetry and electrochemical impedance spectroscopy. It has been shown that the most promising in terms of the rate of interaction with the yeast B. adeninivorans is the system based on poly(thionine), single-walled carbon nanotubes (SWCNT), and neutral red (kint = 0.071 dm3/(g·s)). The biosensor based on this system is characterized by high sensitivity (the lower limit of determined BOD concentrations is 0.4 mgO2/dm3). Sample analysis by means of the developed analytical system showed that the results of the standard dilution method and those using the biosensor differed insignificantly. Thus, for the first time, the fundamental possibility of effectively using nanocomposite materials based on SWCNT and the redox-active polymer poly(thionine) as one of the components of two-mediator systems for electron transfer from yeast microorganisms to the electrode has been shown. It opens up prospects for creating stable and highly sensitive electrochemical systems based on eukaryotes.
Collapse
Affiliation(s)
- Anastasia S. Medvedeva
- Research Center “BioChemTech”, Tula State University, 92 Lenin Avenue, 300012 Tula, Russia
| | - Elena I. Dyakova
- Research Center “BioChemTech”, Tula State University, 92 Lenin Avenue, 300012 Tula, Russia
| | - Lyubov S. Kuznetsova
- Research Center “BioChemTech”, Tula State University, 92 Lenin Avenue, 300012 Tula, Russia
| | - Vladislav G. Mironov
- Research Center “BioChemTech”, Tula State University, 92 Lenin Avenue, 300012 Tula, Russia
| | - George K. Gurkin
- Research Center “BioChemTech”, Tula State University, 92 Lenin Avenue, 300012 Tula, Russia
| | - Tatiana V. Rogova
- Research Center “BioChemTech”, Tula State University, 92 Lenin Avenue, 300012 Tula, Russia
| | - Anna S. Kharkova
- Research Center “BioChemTech”, Tula State University, 92 Lenin Avenue, 300012 Tula, Russia
| | - Pavel V. Melnikov
- M. V. Lomonosov Institute of Fine Chemical Technologies, MIREA—Russian Technological University, 119571 Moscow, Russia
| | - Alina O. Naumova
- M. V. Lomonosov Institute of Fine Chemical Technologies, MIREA—Russian Technological University, 119571 Moscow, Russia
| | - Denis N. Butusov
- Computer-Aided Design Department, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Vyacheslav A. Arlyapov
- Research Center “BioChemTech”, Tula State University, 92 Lenin Avenue, 300012 Tula, Russia
| |
Collapse
|
8
|
Su H, Yan X, Zhao Q, Liao C, Tian L, Wang Z, Wan Y, Li N, Wang X. Layered Design of a Highly Repeatable Electroactive Biofilm for a Standardized Biochemical Oxygen Demand Sensor. ACS Sens 2023; 8:2383-2390. [PMID: 37249569 DOI: 10.1021/acssensors.3c00583] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Microbial electrochemical sensors are promising to monitor bioavailable organics in real environments, but their application is restricted by the unpredictable performance of the electroactive biofilm (EAB), which is randomly acclimated from environmental microflora. With a long-term stable EAB as a template, we successfully designed EAB (DEAB) by the sequential growth of Geobacter anodireducens and automatched microbes, achieving a reproducible high current than those naturally acclimated from wastewater (NEAB). Pre-inoculation of planktonic aerobes as oxygen bioscavengers was necessary to ensure the colonization of Geobacter in the inner layer, and the abundant Geobacter (50%) in DEAB guaranteed 4 times higher current density with a 15-fold smaller variation among 20 replicates than those of NEAB. The sensor constructed with DEAB exhibited a shorter measuring time and a precise biochemical oxygen demand (BOD) measurement with acetate, real domestic wastewater, and supernatant of anaerobic digestion. Here, we for the first time proposed an applicable strategy to standardize EABs for BOD sensors, which is also crucial to ensure a stable performance of all bioelectrochemical technologies.
Collapse
Affiliation(s)
- Huijuan Su
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Xuejun Yan
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Qian Zhao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Lili Tian
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Ziyuan Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Yuxuan Wan
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Nan Li
- School of Environmental Science and Engineering, Tianjin University, No. 35 Yaguan Road, Jinnan District, Tianjin 300350, China
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| |
Collapse
|
9
|
Zang Y, Cao B, Zhao H, Xie B, Ge Y, Yi Y, Liu H. On-site determination of water toxicity based on freeze-dried electrochemically active bacteria. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 867:161432. [PMID: 36623651 DOI: 10.1016/j.scitotenv.2023.161432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 01/03/2023] [Accepted: 01/03/2023] [Indexed: 06/17/2023]
Abstract
Our previous studies have reported water toxicity determination with a fresh electrochemically active bacteria (EAB) suspension as the sensing element, which exhibits high sensitivity and has great prospects in providing early warning about water pollution. However, because the preparation of fresh EAB suspensions is time-consuming, these studies are not suitable for the on-site determination of water toxicity. To solve this problem, this study investigated the rapid preparation of an EAB suspension by the rehydration of freeze-dried EABs and established a novel method for the on-site determination of water toxicity based on the freeze-dried EAB model strain Shewanella oneidensis MR-1. The results demonstrate that the optimal cryoprotectant for S. oneidensis MR-1 freeze drying is 7.5 % (w/v) skimmed milk powder. Compared with fresh S. oneidensis MR-1, freeze-dried S. oneidensis MR-1 exhibits similar extracellular electron transfer (EET) performance (74.7 % ± 0.3 %) and slightly lower sensitivity for water toxicity determination (65.8 % ± 2.2 %) with the optimal cryoprotectant. On-site determination of water toxicity was realized by using freeze-dried S. oneidensis MR-1, and the detection limits of five common toxic pollutants (Cd2+, Pb2+, Cu2+, phenol and dichlorophenol) reached 0.5 mg/L. Water toxicity determination is capable of resisting common interferences, e.g., glucose, lactate, nitrate and nitrite, and shows high accuracy in practical applications.
Collapse
Affiliation(s)
- Yuxuan Zang
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100191, China
| | - Bo Cao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100191, China
| | - Hongyu Zhao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100191, China
| | - Beizhen Xie
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100191, China
| | - Yanhong Ge
- Infore Environment Technology Group, Foshan 528000, Guangdong Province, China
| | - Yue Yi
- School of Life, Beijing Institute of Technology, 100081, China.
| | - Hong Liu
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100191, China.
| |
Collapse
|
10
|
Wang Z, Liao C, Zhong Z, Liu S, Li M, Wang X. Design, optimization and application of a highly sensitive microbial electrolytic cell-based BOD biosensor. ENVIRONMENTAL RESEARCH 2023; 216:114533. [PMID: 36241074 DOI: 10.1016/j.envres.2022.114533] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 09/24/2022] [Accepted: 10/05/2022] [Indexed: 06/16/2023]
Abstract
Biochemical oxygen demand (BOD) is an important biochemical indicator for determining the degree of water pollution and guiding the design of wastewater treatment processes. BOD sensors based on microbial electrochemical technology can conduct real-time online monitoring of organic matter and have attracted extensive attention. However, research on microbial electrolytic cell (MEC)-type BOD sensors is at the stage of theoretical exploration. Here, we designed and optimized a highly sensitive MEC-type BOD sensor by screening inoculants, comparing electrode materials, and optimizing the reactor configuration. The results showed that effective means to optimize a BOD sensor for fast activation and sensitive testing included the inoculation of the MEC reactor effluent with large amounts of biomass and highly active bacteria, selection of carbon felt electrodes with excellent adsorption and permeability, miniaturization of the reactor, regulation of suitable electrode spacing, and design of the penetrating fluid structure. Then, the optimized sensing system was applied to determine the BOD concentration in model solutions of sodium acetate in a laboratory environment, where it accurately measured BOD concentrations in the range of 10-500 mg/L and maintained good parallelism during long-term operation. Next, the MEC-type BOD sensors were put into practice in the field as an alarm for accidents at an actual sewage plant. The whole BOD sensing system was quickly assembled on site and started up, and it gave an early warning shortly after the concentration of organic matter in the water suddenly increased, thus showing a high potential for engineering applications. This study broadened the domains of application of MEC-type BOD sensors in environmental monitoring, and promoted the development of technological innovation in water ecology and environmental monitoring.
Collapse
Affiliation(s)
- Ziyuan Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China.
| | - Zihan Zhong
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Siyan Liu
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Ming Li
- Engelbart (Beijing) Ecological Technology Co., Ltd, Beijing Shunyi Sino-German Industrial Park Sino-German Building 6F, Beijing, 101399, China
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China.
| |
Collapse
|
11
|
AlSawaftah N, Abuwatfa W, Darwish N, Husseini GA. A Review on Membrane Biofouling: Prediction, Characterization, and Mitigation. MEMBRANES 2022; 12:membranes12121271. [PMID: 36557178 PMCID: PMC9787789 DOI: 10.3390/membranes12121271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 12/06/2022] [Accepted: 12/10/2022] [Indexed: 05/12/2023]
Abstract
Water scarcity is an increasing problem on every continent, which instigated the search for novel ways to provide clean water suitable for human use; one such way is desalination. Desalination refers to the process of purifying salts and contaminants to produce water suitable for domestic and industrial applications. Due to the high costs and energy consumption associated with some desalination techniques, membrane-based technologies have emerged as a promising alternative water treatment, due to their high energy efficiency, operational simplicity, and lower cost. However, membrane fouling is a major challenge to membrane-based separation as it has detrimental effects on the membrane's performance and integrity. Based on the type of accumulated foulants, fouling can be classified into particulate, organic, inorganic, and biofouling. Biofouling is considered the most problematic among the four fouling categories. Therefore, proper characterization and prediction of biofouling are essential for creating efficient control and mitigation strategies to minimize the damage associated with biofouling. Moreover, the use of artificial intelligence (AI) in predicting membrane fouling has garnered a great deal of attention due to its adaptive capability and prediction accuracy. This paper presents an overview of the membrane biofouling mechanisms, characterization techniques, and predictive methods with a focus on AI-based techniques, and mitigation strategies.
Collapse
Affiliation(s)
- Nour AlSawaftah
- Department of Chemical and Biological Engineering, College of Engineering, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates
- Materials Science and Engineering Program, College of Arts and Sciences, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates
| | - Waad Abuwatfa
- Department of Chemical and Biological Engineering, College of Engineering, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates
- Materials Science and Engineering Program, College of Arts and Sciences, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates
| | - Naif Darwish
- Department of Chemical and Biological Engineering, College of Engineering, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates
| | - Ghaleb A. Husseini
- Department of Chemical and Biological Engineering, College of Engineering, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates
- Materials Science and Engineering Program, College of Arts and Sciences, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates
- Correspondence:
| |
Collapse
|
12
|
Yang Q, Lai M, Liu D, Zhang J, Zhang Y, Liu C, Xu X, Jia J. Biosensor nanostructures based on dual-chamber microbial fuel cells for rapid determination of biochemical oxygen demand and microbial community analysis. J Solid State Electrochem 2022. [DOI: 10.1007/s10008-022-05351-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
13
|
Chu N, Jiang Y, Zhang L, Zeng RJ, Li D. Biocathode prepared at low anodic potentials achieved a higher response for water biotoxicity monitoring after polarity reversal. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 847:157553. [PMID: 35878860 DOI: 10.1016/j.scitotenv.2022.157553] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 07/17/2022] [Accepted: 07/18/2022] [Indexed: 06/15/2023]
Abstract
Microbial electrochemical sensors equipped with biocathode sensing elements have attracted a growing interest, but their startup and recovery properties remain unclear. In this study, the approach of polarity reversal was applied for the biocathode sensing element fabrication and biosensor recovery. The stimulating/suppressing effect of formaldehyde was determined by the anode potential before polarity reversal as well as the increased trials of toxic exposure. Increasing anode potential from -0.3 V to +0.3 V before polarity reversal, the baseline electric signal was changed from -0.028 ± 0.001 mA to -0.005 ± 0.003 mA, while the maximum normalized electrical signal (NES) was increased from 1.1 ± 0.1 to 4.1 ± 1.9, and thus a general downtrend was observed for Response as a newly induced indicator. Polarity reversal failed to recover the electroactivity of these poisoned bioelectrodes. This study demonstrated that electrode potential was critical when using the approach of polarity reversal to construct the biocathode sensing element, and revealed an urgent need for strategies toward high recoverability of such biosensors.
Collapse
Affiliation(s)
- Na Chu
- CAS Key Laboratory of Environmental and Applied Microbiology, Environmental Microbiology Key Laboratory of Sichuan Province, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou 350002, China
| | - Lixia Zhang
- CAS Key Laboratory of Environmental and Applied Microbiology, Environmental Microbiology Key Laboratory of Sichuan Province, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China
| | - Raymond Jianxiong Zeng
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou 350002, China
| | - Daping Li
- CAS Key Laboratory of Environmental and Applied Microbiology, Environmental Microbiology Key Laboratory of Sichuan Province, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China.
| |
Collapse
|
14
|
Arlyapov VA, Plekhanova YV, Kamanina OA, Nakamura H, Reshetilov AN. Microbial Biosensors for Rapid Determination of Biochemical Oxygen Demand: Approaches, Tendencies and Development Prospects. BIOSENSORS 2022; 12:842. [PMID: 36290979 PMCID: PMC9599453 DOI: 10.3390/bios12100842] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 09/23/2022] [Accepted: 10/01/2022] [Indexed: 06/16/2023]
Abstract
One of the main indices of the quality of water is the biochemical oxygen demand (BOD). A little over 40 years have passed since the practical application of the first microbial sensor for the determination of BOD, presented by the Japanese professor Isao Karube. This time span has brought new knowledge to and practical developments in the use of a wide range of microbial cells based on BOD biosensors. At present, this field of biotechnology is becoming an independent discipline. The traditional BOD analysis (BOD5) has not changed over many years; it takes no less than 5 days to carry out. Microbial biosensors can be used as an alternative technique for assessing the BOD attract attention because they can reduce hundredfold the time required to measure it. The review examines the experience of the creation and practical application of BOD biosensors accumulated by the international community. Special attention is paid to the use of multiple cell immobilization methods, signal registration techniques, mediators and cell consortia contained in the bioreceptor. We consider the use of nanomaterials in the modification of analytical devices developed for BOD evaluation and discuss the prospects of developing new practically important biosensor models.
Collapse
Affiliation(s)
- Vyacheslav A. Arlyapov
- Laboratory of Biologically Active Compounds and Biocomposites, Federal State Budgetary Educational Establishment of Higher Education “Tula State University”, 300012 Tula, Russia
| | - Yulia V. Plekhanova
- Pushchino Center for Biological Research of the Russian Academy of Sciences, G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia
| | - Olga A. Kamanina
- Laboratory of Biologically Active Compounds and Biocomposites, Federal State Budgetary Educational Establishment of Higher Education “Tula State University”, 300012 Tula, Russia
| | - Hideaki Nakamura
- Department of Liberal Arts, Tokyo University of Technology, 1404-1 Katakura, Hachioji, Tokyo 192-0982, Japan
| | - Anatoly N. Reshetilov
- Pushchino Center for Biological Research of the Russian Academy of Sciences, G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia
| |
Collapse
|
15
|
Hu Y, Han X, Shi L, Cao B. Electrochemically active biofilm-enabled biosensors: Current status and opportunities for biofilm engineering. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
16
|
Kurbanalieva S, Arlyapov V, Kharkova A, Perchikov R, Kamanina O, Melnikov P, Popova N, Machulin A, Tarasov S, Saverina E, Vereshchagin A, Reshetilov A. Electroactive Biofilms of Activated Sludge Microorganisms on a Nanostructured Surface as the Basis for a Highly Sensitive Biochemical Oxygen Demand Biosensor. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22166049. [PMID: 36015810 PMCID: PMC9414782 DOI: 10.3390/s22166049] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 08/08/2022] [Accepted: 08/09/2022] [Indexed: 05/04/2023]
Abstract
The possibility of the developing a biochemical oxygen demand (BOD) biosensor based on electroactive biofilms of activated sludge grown on the surface of a graphite-paste electrode modified with carbon nanotubes was studied. A complex of microscopic methods controlled biofilm formation: optical microscopy with phase contrast, scanning electron microscopy, and laser confocal microscopy. The features of charge transfer in the obtained electroactive biofilms were studied using the methods of cyclic voltammetry and electrochemical impedance spectroscopy. The rate constant of the interaction of microorganisms with the extracellular electron carrier (0.79 ± 0.03 dm3(g s)-1) and the heterogeneous rate constant of electron transfer (0.34 ± 0.02 cm s-1) were determined using the cyclic voltammetry method. These results revealed that the modification of the carbon nanotubes' (CNT) electrode surface makes it possible to create electroactive biofilms. An analysis of the metrological and analytical characteristics of the created biosensors showed that the lower limit of the biosensor based on an electroactive biofilm of activated sludge is 0.41 mgO2/dm3, which makes it possible to analyze almost any water sample. Analysis of 12 surface water samples showed a high correlation (R2 = 0.99) with the results of the standard method for determining biochemical oxygen demand.
Collapse
Affiliation(s)
- Saniyat Kurbanalieva
- Laboratory of Biologically Active Compounds and Biocomposites, Tula State University, Lenin Pr. 92, Tula 300012, Russia
| | - Vyacheslav Arlyapov
- Laboratory of Biologically Active Compounds and Biocomposites, Tula State University, Lenin Pr. 92, Tula 300012, Russia
- Correspondence:
| | - Anna Kharkova
- Laboratory of Biologically Active Compounds and Biocomposites, Tula State University, Lenin Pr. 92, Tula 300012, Russia
| | - Roman Perchikov
- Laboratory of Biologically Active Compounds and Biocomposites, Tula State University, Lenin Pr. 92, Tula 300012, Russia
| | - Olga Kamanina
- Laboratory of Biologically Active Compounds and Biocomposites, Tula State University, Lenin Pr. 92, Tula 300012, Russia
| | - Pavel Melnikov
- M. V. Lomonosov Institute of Fine Chemical Technologies, MIREA—Russian Technological University, Prosp. Vernadskogo 86, Moscow 119571, Russia
| | - Nadezhda Popova
- Federal State Budgetary Institution of Science Institute of Physical Chemistry and Electrochemistry of the Russian Academy of Sciences, Leninsky Prosp., 31 k. 4., Moscow 119071, Russia
| | - Andrey Machulin
- Institute of Biochemistry and Physiology of Microorganisms of the Russian Academy of Sciences—A Separate Subdivision of the FRC Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences, Prosp. Science 3, Pushchino 142290, Russia
| | - Sergey Tarasov
- Institute of Biochemistry and Physiology of Microorganisms of the Russian Academy of Sciences—A Separate Subdivision of the FRC Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences, Prosp. Science 3, Pushchino 142290, Russia
| | - Evgeniya Saverina
- N. D. Zelinsky Institute of Organic Chemistry, Leninsky Pr. 47, Moscow 119991, Russia
| | - Anatoly Vereshchagin
- N. D. Zelinsky Institute of Organic Chemistry, Leninsky Pr. 47, Moscow 119991, Russia
| | - Anatoly Reshetilov
- Institute of Biochemistry and Physiology of Microorganisms of the Russian Academy of Sciences—A Separate Subdivision of the FRC Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences, Prosp. Science 3, Pushchino 142290, Russia
| |
Collapse
|
17
|
Dhall A, Ramjee R, Oh MJ, Tao K, Hwang G. A 3D-Printed Customizable Platform for Multiplex Dynamic Biofilm Studies. ADVANCED MATERIALS TECHNOLOGIES 2022; 7:2200138. [PMID: 35935146 PMCID: PMC9347831 DOI: 10.1002/admt.202200138] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Biofilms are communities of microbes that colonize surfaces. While several biofilm experimental models exist, they often have limited replications of spatiotemporal dynamics surrounding biofilms. For a better understanding dynamic and complex biofilm development, this manuscript presents a customizable platform compatible with off-the-shelf well plates that can monitor microbial adhesion, growth, and associated parameters under various relevant scenarios by taking advantage of 3D printing. The system i) holds any substrate in a stable, vertical position, ii) subjects samples to flow at different angles, iii) switches between static and dynamic modes during an experiment, and iv) allows multiplexing and real-time monitoring of biofilm parameters. Simulated fluid dynamics is employed to estimate flow patterns around discs and shear stresses at disc surfaces. A 3D printed peristaltic pump and a customized pH measurement system for real-time tracking of spent biofilm culture media are equipped with a graphical user interface that grants control over all experimental parameters. The system is tested under static and dynamic conditions with Streptococcus mutans using different carbon sources. By monitoring the effluent pH and characterizing biochemical, microbiological, and morphological properties of cultured biofilms, distinct properties are demonstrated. This novel platform liberates designing experimental strategies for investigations of biofilms under various conditions.
Collapse
Affiliation(s)
- Atul Dhall
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Ravikiran Ramjee
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Bioengineering, School of Engineering and Applied Sciences, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Min Jun Oh
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Chemical and Biomolecular Engineering, School of Engineering and Applied Sciences, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Kevin Tao
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Biology, School of Arts and Sciences, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Geelsu Hwang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Center for Innovation & Precision Dentistry, School of Dental Medicine, School of Engineering and Applied Sciences, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
18
|
Kuznetsova LS, Arlyapov VA, Kamanina OA, Lantsova EA, Tarasov SE, Reshetilov AN. Development of Nanocomposite Materials Based on Conductive Polymers for Using in Glucose Biosensor. Polymers (Basel) 2022; 14:polym14081543. [PMID: 35458293 PMCID: PMC9026068 DOI: 10.3390/polym14081543] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 03/31/2022] [Accepted: 04/03/2022] [Indexed: 12/11/2022] Open
Abstract
Electropolymerized neutral red, thionine, and aniline were used as part of hybrid nanocomposite conductive polymers, to create an amperometric reagent-less biosensor for glucose determination. The structure of the obtained polymers was studied using infrared (IR) spectroscopy and scanning electron microscopy. Electrochemical characteristics were studied by cyclic voltammetry and impedance spectroscopy. It was shown that, from the point of view of both the rate of electron transfer to the electrode, and the rate of interaction with the active center of glucose oxidase (GOx), the most promising is a new nanocomposite based on poly(neutral red) (pNR) and thermally expanded graphite (TEG). The sensor based on the created nanocomposite material is characterized by a sensitivity of 1000 ± 200 nA × dm3/mmol; the lower limit of the determined glucose concentrations is 0.006 mmol/L. The glucose biosensor based on this nanocomposite was characterized by a high correlation (R2 = 0.9828) with the results of determining the glucose content in human blood using the standard method. Statistical analysis did not reveal any deviations of the results obtained using this biosensor and the reference method. Therefore, the developed biosensor can be used as an alternative to the standard analysis method and as a prototype for creating sensitive and accurate glucometers, as well as biosensors to assess other metabolites.
Collapse
Affiliation(s)
- Lyubov S. Kuznetsova
- Laboratory of Biologically Active Compounds and Biocomposites, Tula State University, Lenin pr. 92, 300012 Tula, Russia; (L.S.K.); (O.A.K.); (E.A.L.)
| | - Vyacheslav A. Arlyapov
- Laboratory of Biologically Active Compounds and Biocomposites, Tula State University, Lenin pr. 92, 300012 Tula, Russia; (L.S.K.); (O.A.K.); (E.A.L.)
- Correspondence:
| | - Olga A. Kamanina
- Laboratory of Biologically Active Compounds and Biocomposites, Tula State University, Lenin pr. 92, 300012 Tula, Russia; (L.S.K.); (O.A.K.); (E.A.L.)
| | - Elizaveta A. Lantsova
- Laboratory of Biologically Active Compounds and Biocomposites, Tula State University, Lenin pr. 92, 300012 Tula, Russia; (L.S.K.); (O.A.K.); (E.A.L.)
| | - Sergey E. Tarasov
- Institute of Biochemistry and Physiology of Microorganisms of the Russian Academy of Sciences, Federal Research Center “Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences”, Pushchino, pr. Science, 5, 142290 Moscow, Russia; (S.E.T.); (A.N.R.)
| | - Anatoly N. Reshetilov
- Institute of Biochemistry and Physiology of Microorganisms of the Russian Academy of Sciences, Federal Research Center “Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences”, Pushchino, pr. Science, 5, 142290 Moscow, Russia; (S.E.T.); (A.N.R.)
| |
Collapse
|
19
|
Yi Y, Liang A, Luo L, Zang Y, Zhao H, Luo A. A novel real-time TMAO detection method based on microbial electrochemical technology. Bioelectrochemistry 2022; 144:108038. [PMID: 34906816 DOI: 10.1016/j.bioelechem.2021.108038] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Revised: 12/04/2021] [Accepted: 12/06/2021] [Indexed: 01/30/2023]
Abstract
Trimethylamine N-oxide (TMAO) is considered to be a novel biomarker of cardiovascular diseases. However, the traditional TMAO detection method has failed to meet the requirements of real-time and point-of-care tests. Herein, a novel TMAO detection method based on microbial electrochemical technology is established, which realizes the direct conversion of TMAO concentration into electrical signals. Attached Shewanella loihica PV-4 was first proven to be capable of simultaneous inward extracellular electron transfer and TMAO reduction. The TMAO detection method showed a wide linear range of 0 to 250 μM, a high sensitivity of 23.92 μA/mM, and a low limit of detection of 5.96 μM. In addition, the TMAO detection process was accomplished within 600 s, with an acceptable accuracy of 90% in the real serum, showing high feasibility in clinical applications.
Collapse
Affiliation(s)
- Yue Yi
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China; Key Laboratory of Molecular Medicine and Biotherapy, Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Axin Liang
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China; Key Laboratory of Molecular Medicine and Biotherapy, Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Lin Luo
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China; Key Laboratory of Molecular Medicine and Biotherapy, Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Yuxuan Zang
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Hongyu Zhao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Aiqin Luo
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China; Key Laboratory of Molecular Medicine and Biotherapy, Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China.
| |
Collapse
|
20
|
Abstract
Microbial biofilms have caused serious concerns in healthcare, medical, and food industries because of their intrinsic resistance against conventional antibiotics and cleaning procedures and their capability to firmly adhere on surfaces for persistent contamination. These global issues strongly motivate researchers to develop novel methodologies to investigate the kinetics underlying biofilm formation, to understand the response of the biofilm with different chemical and physical treatments, and to identify biofilm-specific drugs with high-throughput screenings. Meanwhile microbial biofilms can also be utilized positively as sensing elements in cell-based sensors due to their strong adhesion on surfaces. In this perspective, we provide an overview on the connections between sensing and microbial biofilms, focusing on tools used to investigate biofilm properties, kinetics, and their response to chemicals or physical agents, and biofilm-based sensors, a type of biosensor using the bacterial biofilm as a biorecognition element to capture the presence of the target of interest by measuring the metabolic activity of the immobilized microbial cells. Finally we discuss possible new research directions for the development of robust and rapid biofilm related sensors with high temporal and spatial resolutions, pertinent to a wide range of applications.
Collapse
Affiliation(s)
- Riccardo Funari
- Dipartimento di Fisica “M. Merlin”, Università degli Studi di Bari Aldo Moro, Via Amendola, 173, Bari 70125, Italy
- CNR, Istituto di Fotonica e Nanotecnologie, Via Amendola, 173, 70125 Bari, Italy
| | - Amy Q. Shen
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, 1919-1 Tancha, Onna-son, Okinawa 904-0495, Japan
| |
Collapse
|
21
|
Zang Y, Zhao H, Cao B, Xie B, Yi Y, Liu H. Enhancing the sensitivity of water toxicity detection based on suspended Shewanella oneidensis MR-1 by reversing extracellular electron transfer direction. Anal Bioanal Chem 2022; 414:3057-3066. [PMID: 35192018 DOI: 10.1007/s00216-022-03919-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 01/11/2022] [Accepted: 01/21/2022] [Indexed: 01/10/2023]
Abstract
Water toxicity detection is of great significance to ensure the safety of water supply. With suspended electrochemically active bacteria (EAB) as the sensing element, a novel microbial electrochemical sensor (MES) has recently been reported for the real-time detection of water toxicity, but its practical applications need to further improve the sensitivity. Extracellular electron transfer (EET) is an important factor affecting MES performance. In the study, the EET of suspended EAB-based MES was optimized to further enhance the sensitivity. Firstly, by using a model EAB stain Shewanella oneidensis MR-1, it was revealed that the sensitivity was increased at most 2.7 times with inward EET (i.e., cathodic polarization). Then, a novel conjecture based on electron transfer and energy fluxes was proposed and testified to explain this phenomenon. Finally, three key operating parameters of inward EET were orthogonally optimized. The optimized parameters of inward EET included a potential of - 0.5 V, a cell density of 1.8 × 108 CFU/mL, and an electron acceptor concentration of 15 mM.
Collapse
Affiliation(s)
- Yuxuan Zang
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China.,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Hongyu Zhao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China.,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Bo Cao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China.,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Beizhen Xie
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China.,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Yue Yi
- School of Life, Beijing Institute of Technology, No. 5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
| | - Hong Liu
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China. .,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China. .,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China.
| |
Collapse
|
22
|
Chu N, Cai J, Li Z, Gao Y, Liang Q, Hao W, Liu P, Jiang Y, Zeng RJ. Indicators of water biotoxicity obtained from turn-off microbial electrochemical sensors. CHEMOSPHERE 2022; 286:131725. [PMID: 34352539 DOI: 10.1016/j.chemosphere.2021.131725] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 07/15/2021] [Accepted: 07/28/2021] [Indexed: 06/13/2023]
Abstract
The development of biosensors is critical to reducing potential risks associated with contamination accidents. However, the application of microbial electrochemical sensors for water biotoxicity monitoring is hampered by the lack of an indicator with high response magnitudes. In this study, microbial electrochemical sensors were fabricated with interdigitated electrode arrays (IDAs), and indicators from various electrochemical analyses were comprehensively investigated. Only the peak of cyclic voltammetry (CV) was highly linearly correlated with the commonly used current indicator during the enrichment of the electroactive biofilm. The resistance fitted from the electrochemical impedance spectroscopy (EIS) data provided a comparable and even higher inhibition ratio (IR) than the current during toxicity assessments. The differential pulse voltammetry (DPV) did not exhibit a higher sensitivity than the CV peak. However, no clear response was observed in the real-time impedance analysis for use in water biotoxicity monitoring. Most of the microbes were in the propidium iodide (PI)-permeable state after the toxicity assessments, although the current was fully recovered. This study demonstrates the potential to use EIS data as indicators of water biotoxicity using microbial electrochemical sensors.
Collapse
Affiliation(s)
- Na Chu
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Jiayi Cai
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Zhigang Li
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Yu Gao
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Qinjun Liang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Wen Hao
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China
| | - Panpan Liu
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, Henan, 450001, China
| | - Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China.
| | - Raymond Jianxiong Zeng
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| |
Collapse
|
23
|
Qi X, Wang S, Jiang Y, Liu P, Hao W, Han J, Zhou Y, Huang X, Liang P. Additional polypyrrole as conductive medium in artificial electrochemically active biofilm (EAB) to increase the sensitivity of EAB based biosensor in water quality early-warning. Biosens Bioelectron 2021; 190:113453. [PMID: 34174528 DOI: 10.1016/j.bios.2021.113453] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 06/09/2021] [Accepted: 06/17/2021] [Indexed: 12/23/2022]
Abstract
Researchers believe that adding conductive mediums in electrochemically active biofilms (EABs) would improve the sensitivity of EAB-based biosensor for real-time water quality early-warning through facilitating the extracellular electron transfer (EET), which has been hardly evidenced mostly because naturally formed EABs employed in previous biosensor studies were recognized distinct and incapable of delivering comparable electrical signals. By preparing artificial EABs where Shewanella oneidensis MR-1 was encapsulated in sodium alginate (SA), this study solved how polypyrrole (PPy) as conductive medium would affect the sensitivity of EAB-based biosensor, as well as mass transfer of toxicant during this process. Different mass ratios (0.125:1, 0.25:1 and 1:1) of PPy over SA were tested, and the sensitivity promoted by 20%, 15% and 6%, respectively. Results indicated that a small amount of PPy addition (PPy: SA = 0.125: 1 in mass ratio) was more effective to increase the biosensor's sensitivity compared to larger amount of PPy employed in EAB. This was when improved conductivity introduced by PPy would dominate in affecting the sensitivity over contrarily weakened mass transfer in the meantime.
Collapse
Affiliation(s)
- Xiang Qi
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Shuyi Wang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Panpan Liu
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, 450001, PR China
| | - Wen Hao
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Jinbin Han
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Yuexi Zhou
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Xia Huang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Peng Liang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, PR China.
| |
Collapse
|
24
|
Guo H, Ji J, Sun J, Zhang Y, Sun X. Development of a living mammalian cell-based biosensor for the monitoring and evaluation of synergetic toxicity of cadmium and deoxynivalenol. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 771:144823. [PMID: 33545470 DOI: 10.1016/j.scitotenv.2020.144823] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 12/15/2020] [Accepted: 12/21/2020] [Indexed: 06/12/2023]
Abstract
With increased interest in the toxic interactions of multiple toxins, biotoxicity models have to be urgently developed for joint toxicity evaluation. This study aimed to develop an optical biosensor based on living mammary cells for monitoring of cadmium (Cd)/deoxynivalenol (DON) in water and evaluating their combined toxicity. Our previous survey found that DON and Cd appeared simultaneously in various products, and RNA seq revealed that AP-1 participated in combined toxicity of DON+Cd in HT-29 cells. Thus AP-1 site-mCherry-based biosensors were constructed, optimized, and then tested for their applicability and stable fluorescence response activities. DON+Cd2+, DON, and Cd2+ induced dose-dependent fluorescence signal in the biosensors (at environmental exposure levels). The enhanced fluorescence signal suggested that the toxicity of DON+Cd2+ was enhanced compared with that of single toxin. The advantages of the biosensors include: I) The easy and visual screening of multiple toxins on the basis of environmental exposure levels; II) Potential as a broad-spectrum tool for joint toxicity evaluation of DON+Cd; III) Pollution-free and stable fluorescence response; IV) A slight effect on viability.
Collapse
Affiliation(s)
- Hongyan Guo
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Jian Ji
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Jiadi Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Yinzhi Zhang
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Xiulan Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu 214122, PR China.
| |
Collapse
|
25
|
Chu N, Liang Q, Hao W, Jiang Y, Zeng RJ. Micro-microbial electrochemical sensor equipped with combined bioanode and biocathode for water biotoxicity monitoring. BIORESOURCE TECHNOLOGY 2021; 326:124743. [PMID: 33503515 DOI: 10.1016/j.biortech.2021.124743] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 01/12/2021] [Accepted: 01/15/2021] [Indexed: 06/12/2023]
Abstract
The development of low-cost biosensors for water monitoring is expected to reduce potential risks from contamination accidents. This study reported a novel micro-microbial electrochemical sensor using combined bioanode and biocathode as the sensing element, characterized by a sequential flowing membrane-free channel and a bilateral passive oxygen supply. A decrease in the ratio of number of bioanode to biocathode resulted in a lower power generation, whereas, achieving a similar or even higher toxic response. The voltage was affected by both the flow rate and the acetate concentration. With the increased acetate concentration, a clear trade-off was observed between the electroactivity stimulation of bioanode vs. the electroactivity maintenance of biocathode. Biosensors made good response to the injection of formaldehyde (10 µL of 0.25%, and 100 µL of 0.025%) into the inlet. A high microbial diversity was observed. This work can lead to a revolutionizing way of water monitoring using self-powered micro-biosensors.
Collapse
Affiliation(s)
- Na Chu
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| | - Qinjun Liang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| | - Wen Hao
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China.
| | - Raymond Jianxiong Zeng
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| |
Collapse
|
26
|
Hassan RY, Febbraio F, Andreescu S. Microbial Electrochemical Systems: Principles, Construction and Biosensing Applications. SENSORS (BASEL, SWITZERLAND) 2021; 21:1279. [PMID: 33670122 PMCID: PMC7916843 DOI: 10.3390/s21041279] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 02/02/2021] [Accepted: 02/04/2021] [Indexed: 02/07/2023]
Abstract
Microbial electrochemical systems are a fast emerging technology that use microorganisms to harvest the chemical energy from bioorganic materials to produce electrical power. Due to their flexibility and the wide variety of materials that can be used as a source, these devices show promise for applications in many fields including energy, environment and sensing. Microbial electrochemical systems rely on the integration of microbial cells, bioelectrochemistry, material science and electrochemical technologies to achieve effective conversion of the chemical energy stored in organic materials into electrical power. Therefore, the interaction between microorganisms and electrodes and their operation at physiological important potentials are critical for their development. This article provides an overview of the principles and applications of microbial electrochemical systems, their development status and potential for implementation in the biosensing field. It also provides a discussion of the recent developments in the selection of electrode materials to improve electron transfer using nanomaterials along with challenges for achieving practical implementation, and examples of applications in the biosensing field.
Collapse
Affiliation(s)
- Rabeay Y.A. Hassan
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, 6th October City, Giza 12578, Egypt;
- National Research Centre (NRC), Applied Organic Chemistry Department, El Bohouth st., Dokki, Giza 12622, Egypt
| | - Ferdinando Febbraio
- Institute of Biochemistry and Cell Biology, National Research Council (CNR), Via P. Castellino 111, 80131 Naples, Italy;
| | - Silvana Andreescu
- Department of Chemistry and Biomolecular Science, Clarkson University, Potsdam, NY 13699-5810, USA
| |
Collapse
|