1
|
Nguyen HQ, Nguyen VD, Phan VM, Seo TS. Development of a self-contained microfluidic chip and an internet-of-things-based point-of-care device for automated identification of respiratory viruses. LAB ON A CHIP 2024; 24:2485-2496. [PMID: 38587207 DOI: 10.1039/d3lc00933e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/09/2024]
Abstract
The COVID-19 pandemic greatly impacted the in vitro diagnostic market, leading to the development of new technologies such as point-of-care testing (POCT), multiplex testing, and digital health platforms. In this study, we present a self-contained microfluidic chip integrated with an internet-of-things (IoT)-based point-of-care (POC) device for rapid and sensitive diagnosis of respiratory viruses. Our platform enables sample-to-answer diagnostics within 70 min by automating RNA extraction, reverse transcription-loop-mediated isothermal amplification (RT-LAMP), and fluorescence detection. The microfluidic chip is designed to store all the necessary reagents for the entire diagnostic assay, including a lysis buffer, a washing buffer, an elution buffer, and a lyophilized RT-LAMP cocktail. It can perform nucleic acid extraction, aliquoting, and gene amplification in multiple reaction chambers without cross-contamination. The IoT-based POC device consists of a Raspberry Pi 4 for device control and data processing, a CMOS sensor for measuring fluorescence signals, a resistive heater panel for temperature control, and solenoid valves for controlling the movement of on-chip reagent solutions. The proposed device is portable and features a touchscreen for user control and result display. We evaluated the performance of the platform using 11 clinical respiratory virus samples, including 5 SARS-CoV-2 samples, 2 influenza A samples, and 4 influenza B samples. All tested clinical samples were accurately identified with high specificity and fidelity, demonstrating the ability to simultaneously detect multiple respiratory viruses. The combination of the integrated microfluidic chip with the POC device offers a simple, cost-effective, and scalable solution for rapid molecular diagnosis of respiratory viruses in resource-limited settings.
Collapse
Affiliation(s)
- Huynh Quoc Nguyen
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea.
| | - Van Dan Nguyen
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea.
| | - Vu Minh Phan
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea.
| | - Tae Seok Seo
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea.
| |
Collapse
|
2
|
Shamsaei D, Hsieh SA, Ocaña-Rios I, Ryan SJ, Anderson JL. Smartphone as a fluorescence detector for high-performance liquid chromatography. Anal Chim Acta 2023; 1280:341863. [PMID: 37858553 DOI: 10.1016/j.aca.2023.341863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 09/26/2023] [Accepted: 09/29/2023] [Indexed: 10/21/2023]
Abstract
BACKGROUND Fluorescence detection is employed in high-performance liquid chromatography (HPLC) due to its high specificity and sensitivity. However, it is often limited by expensive components and bulkiness. Recently, advances in technology and electronics have led to the development of smartphones that can serve as portable recording, analysis, and monitoring tools. Smartphone-based detection provides advantages of cost effectiveness, rapid signal/data processing, and the display of results on a handhold monitor. The combination of smartphone-based detection with HPLC can offer unique features that are beneficial in overcoming limitations of commercial fluorescence detectors. (90) RESULTS: A miniaturized and low-cost HPLC fluorescence detector based on a smartphone is introduced for the detection of six fluorescent molecules. The smartphone is able to capture emitted fluorescence in video format while MATLAB code is used for data processing to provide chromatograms based on different detection channels. A custom designed double-channel flow cell was utilized to enable simultaneous detection of fluorescent compounds with different excitation wavelengths. The detector consists of a lab-made flow cell, monochromatic LEDs as the light source, 3D printed housing and connector box, fiber optic cables, and a smartphone. The effects of flow cell geometry, channel width and light slit diameter, as well as a comparison of different flow cell manufacturing techniques, are studied and discussed. The validated system was successfully applied to samples from diverse water sources, yielding spiking recoveries within the range of 91.7% and 109.7%. (141) SIGNIFICANCE: This study introduces the first smartphone-based fluorescence detector for HPLC with cost-effective and customizable flow cells, allowing for the simultaneous detection of fluorescent compounds with different excitation wavelengths and offering a potential solution for the analysis of co-eluting compounds. Beyond its user-friendly interface and low-cost, smartphone detection in HPLC provides tremendous opportunities in further miniaturizing chromatographic instrumentation while offering high sensitivity and can be expanded to other mechanisms of detection. (70).
Collapse
Affiliation(s)
- Danial Shamsaei
- Department of Chemistry, Iowa State University, Ames, IA, 50011, USA
| | - Shu-An Hsieh
- Department of Chemistry, Iowa State University, Ames, IA, 50011, USA
| | - Iran Ocaña-Rios
- Department of Chemistry, Iowa State University, Ames, IA, 50011, USA
| | - Saxon J Ryan
- Department of Agricultural and Biosystems Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Jared L Anderson
- Department of Chemistry, Iowa State University, Ames, IA, 50011, USA.
| |
Collapse
|
3
|
Zayed BA, Ali AN, Elgebaly AA, Talaia NM, Hamed M, Mansour FR. Smartphone-based point-of-care testing of the SARS-CoV-2: A systematic review. SCIENTIFIC AFRICAN 2023; 21:e01757. [PMID: 37351482 PMCID: PMC10256629 DOI: 10.1016/j.sciaf.2023.e01757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 06/03/2023] [Accepted: 06/09/2023] [Indexed: 06/24/2023] Open
Abstract
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus's worldwide pandemic has highlighted the urgent need for reliable, quick, and affordable diagnostic tests for comprehending and controlling the epidemic by tracking the world population. Given how crucial it is to monitor and manage the pandemic, researchers have recently concentrated on creating quick detection techniques. Although PCR is still the preferred clinical diagnostic test, there is a pressing need for substitutes that are sufficiently rapid and cost-effective to provide a diagnosis at the time of use. The creation of a quick and simple POC equipment is necessary for home testing. Our review's goal is to provide an overview of the many methods utilized to identify SARS-CoV 2 in various samples utilizing portable devices, as well as any potential applications for smartphones in epidemiological research and detection. The point of care (POC) employs a range of microfluidic biosensors based on smartphones, including molecular sensors, immunological biosensors, hybrid biosensors, and imaging biosensors. For example, a number of tools have been created for the diagnosis of COVID-19, based on various theories. Integrated portable devices can be created using loop-mediated isothermal amplification, which combines isothermal amplification methods with colorimetric detection. Electrochemical approaches have been regarded as a potential substitute for optical sensing techniques that utilize fluorescence for detection and as being more beneficial to the Minimizing and simplicity of the tools used for detection, together with techniques that can amplify DNA or RNA under constant temperature conditions, without the need for repeated heating and cooling cycles. Many research have used smartphones for virus detection and data visualization, making these techniques more user-friendly and broadly distributed throughout nations. Overall, our research provides a review of different novel, non-invasive, affordable, and efficient methods for identifying COVID-19 contagious infected people and halting the disease's transmission.
Collapse
Affiliation(s)
- Berlanty A Zayed
- Tanta Student Research Academy, Faculty of Medicine, Tanta University, Tanta 31111, Egypt
| | - Ahmed N Ali
- Tanta Student Research Academy, Faculty of Medicine, Tanta University, Tanta 31111, Egypt
| | - Alaa A Elgebaly
- Tanta Student Research Academy, Faculty of Medicine, Tanta University, Tanta 31111, Egypt
| | - Nourhan M Talaia
- Tanta Student Research Academy, Faculty of Medicine, Tanta University, Tanta 31111, Egypt
| | - Mahmoud Hamed
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Elgeish Street, The Medical Campus of Tanta University, Tanta 31111, Egypt
| | - Fotouh R Mansour
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Elgeish Street, The Medical Campus of Tanta University, Tanta 31111, Egypt
| |
Collapse
|
4
|
Kaljurand M, Růžička M, Gorbatsova J, Mazina-Šinkar J. Evaluation of different operating modes of an autosampler for portable capillary electrophoresis. J Chromatogr A 2023; 1705:464201. [PMID: 37451197 DOI: 10.1016/j.chroma.2023.464201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2023] [Revised: 06/29/2023] [Accepted: 07/04/2023] [Indexed: 07/18/2023]
Abstract
A compact, inexpensive sampler instrument for portable capillary electrophoresis (CE) was developed and tested to monitor common inorganic ions in drinking water samples. The sampler uses peristaltic and vacuum pumps and pinch and check valves to control liquid flows. The paper also addresses various aspects of CE associated with portability, open access instrumentation and prospects of CE for citizen science. The extensive use of items provided by the electronic and computer industry contributes to this trend.
Collapse
Affiliation(s)
- Mihkel Kaljurand
- Department of Chemistry and Biotechnology, School of Science, Tallinn University of Technology, Tallinn 12618, Estonia.
| | - Martin Růžička
- Department of Chemistry and Biotechnology, School of Science, Tallinn University of Technology, Tallinn 12618, Estonia
| | - Jelena Gorbatsova
- Department of Chemistry and Biotechnology, School of Science, Tallinn University of Technology, Tallinn 12618, Estonia
| | - Jekaterina Mazina-Šinkar
- Department of Chemistry and Biotechnology, School of Science, Tallinn University of Technology, Tallinn 12618, Estonia
| |
Collapse
|
5
|
Khalaf EM, Sanaan Jabbar H, Mireya Romero-Parra R, Raheem Lateef Al-Awsi G, Setia Budi H, Altamimi AS, Abdulfadhil Gatea M, Falih KT, Singh K, Alkhuzai KA. Smartphone-assisted microfluidic sensor as an intelligent device for on-site determination of food contaminants: Developments and applications. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
6
|
Bui HK, Phan VM, Nguyen HQ, Nguyen VD, Nguyen HV, Seo TS. Function of the Speech Recognition of the Smartphone to Automatically Operate a Portable Sample Pretreatment Microfluidic System. ACS Sens 2023; 8:515-521. [PMID: 36722714 DOI: 10.1021/acssensors.2c01849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
We proposed a portable sample pretreatment microsystem, which can be automatically operated through speech recognition in a smartphone app. The proposed sample pretreatment microsystem consists of a microfluidic chip, an air router, pressure and vacuum lines with air pump motors, six 3-way solenoid valves, and a microcontroller with a Bluetooth module. The command of a human voice conducted the whole process of DNA extraction from pathogenic bacterial samples. Thus, manual interference during the DNA extraction is eliminated, preventing any potential infection from human touch. The palm-sized sample pretreatment microsystem can be run by a portable battery or a conventional smartphone charger. Genomic DNA ofSalmonella typhimuriumwas purified on a chip in less than 1 min with an extraction efficiency of 70 ± 5%.
Collapse
Affiliation(s)
- Hoang Khang Bui
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea
| | - Vu Minh Phan
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea
| | - Huynh Quoc Nguyen
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea
| | - Van Dan Nguyen
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea
| | - Hiep Van Nguyen
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea
| | - Tae Seok Seo
- Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea
| |
Collapse
|
7
|
Novel developments in capillary electrophoresis miniaturization, sampling, detection and portability: An overview of the last decade. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.116941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
8
|
Růžička M, Kaljurand M, Gorbatšova J, Mazina-Šinkar J. Autosampler for portable capillary electrophoresis. J Chromatogr A 2022; 1685:463619. [DOI: 10.1016/j.chroma.2022.463619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 10/27/2022] [Accepted: 10/27/2022] [Indexed: 11/06/2022]
|
9
|
Xing G, Ai J, Wang N, Pu Q. Recent progress of smartphone-assisted microfluidic sensors for point of care testing. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
10
|
Wang AY, Sheng Y, Li W, Jung D, Junek GV, Liu H, Park J, Lee D, Wang M, Maharjan S, Kumashi S, Hao J, Zhang YS, Eggan K, Wang H. A Multimodal and Multifunctional CMOS Cellular Interfacing Array for Digital Physiology and Pathology Featuring an Ultra Dense Pixel Array and Reconfigurable Sampling Rate. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:1057-1074. [PMID: 36417722 DOI: 10.1109/tbcas.2022.3224064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The article presents a fully integrated multimodal and multifunctional CMOS biosensing/actuating array chip and system for multi-dimensional cellular/tissue characterization. The CMOS chip supports up to 1,568 simultaneous parallel readout channels across 21,952 individually addressable multimodal pixels with 13 μm × 13 μm 2-D pixel pitch along with 1,568 Pt reference electrodes. These features allow the CMOS array chip to perform multimodal physiological measurements on living cell/tissue samples with both high throughput and single-cell resolution. Each pixel supports three sensing and one actuating modalities, each reconfigurable for different functionalities, in the form of full array (FA) or fast scan (FS) voltage recording schemes, bright/dim optical detection, 2-/4-point impedance sensing (ZS), and biphasic current stimulation (BCS) with adjustable stimulation area for single-cell or tissue-level stimulation. Each multi-modal pixel contains an 8.84 μm × 11 μm Pt electrode, 4.16 μm × 7.2 μm photodiode (PD), and in-pixel circuits for PD measurements and pixel selection. The chip is fabricated in a standard 130nm BiCMOS process as a proof of concept. The on-chip electrodes are constructed by unique design and in-house post-CMOS fabrication processes, including a critical Al shorting of all pixels during fabrication and Al etching after fabrication that ensures a high-yield planar electrode array on CMOS with high biocompatibility and long-term measurement reliability. For demonstration, extensive biological testing is performed with human and mouse progenitor cells, in which multidimensional biophysiological data are acquired for comprehensive cellular characterization.
Collapse
|
11
|
Ross G, Zhao Y, Bosman A, Geballa-Koukoula A, Zhou H, Elliott C, Nielen M, Rafferty K, Salentijn G. Data handling and ethics of emerging smartphone-based (bio)sensors – Part 1: Best practices and current implementation. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
12
|
Kaljurand M, Mazina-Šinkar J. Portable capillary electrophoresis as a green analytical technology. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
13
|
Zeng R, Qiu M, Wan Q, Huang Z, Liu X, Tang D, Knopp D. Smartphone-Based Electrochemical Immunoassay for Point-of-Care Detection of SARS-CoV-2 Nucleocapsid Protein. Anal Chem 2022; 94:15155-15161. [PMID: 36251341 PMCID: PMC9578645 DOI: 10.1021/acs.analchem.2c03606] [Citation(s) in RCA: 150] [Impact Index Per Article: 50.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 10/07/2022] [Indexed: 11/28/2022]
Abstract
Large-scale, rapid, and inexpensive serological diagnoses of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) are of great interest in reducing virus transmission at the population level; however, their development is greatly plagued by the lack of available point-of-care methods, leading to low detection efficiency. Herein, an ultrasensitive smartphone-based electrochemical immunoassay is reported for rapid (less than 5 min), low-cost, easy-to-implement detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 N protein). Specifically, the electrochemical immunoassay was fabricated on a screen-printed carbon electrode coated with electrodeposited gold nanoparticles, followed by incubation of anti-N antibody (Ab) and bovine serum albumin as the working electrode. Accompanied by the antigen-antibody reaction between the SARS-CoV-2 N protein and the Ab, the electron transfer between the electroactive species [Fe(CN)6]3-/4- and the electrode surface is disturbed, resulting in reduced square-wave voltammetry currents at 0.075 V versus the Ag/AgCl reference electrode. The proposed immunoassay provided a good linear range with SARS-CoV-2 N protein concentrations within the scope of 0.01-1000 ng/mL (R2 = 0.9992) and the limit of detection down to 2.6 pg/mL. Moreover, the detection data are wirelessly transmitted to the interface of the smartphone, and the corresponding SARS-CoV-2 N protein concentration value is calculated and displayed. Therefore, the proposed portable detection mode offers great potential for self-differential diagnosis of residents, which will greatly facilitate the effective control and large-scale screening of virus transmission in resource-limited areas.
Collapse
Affiliation(s)
- Ruijin Zeng
- Key Laboratory of Analytical Science for Food Safety
and Biology (MOE and Fujian Province), Department of Chemistry, Fuzhou
University, Fuzhou350108, People’s Republic of
China
| | - Minghao Qiu
- Key Laboratory of Analytical Science for Food Safety
and Biology (MOE and Fujian Province), Department of Chemistry, Fuzhou
University, Fuzhou350108, People’s Republic of
China
| | - Qing Wan
- School of Electronics and Information Engineering,
Hubei University of Science and Technology, Xianning437100,
People’s Republic of China
| | - Zhisheng Huang
- School of Electronics and Information Engineering,
Hubei University of Science and Technology, Xianning437100,
People’s Republic of China
| | - Xiaolong Liu
- The United Innovation of Mengchao Hepatobiliary
Technology Key Laboratory of Fujian Province, Mengchao Hepatobiliary Hospital
of Fujian Medical University, Fuzhou350025, People’s
Republic of China
| | - Dianping Tang
- Key Laboratory of Analytical Science for Food Safety
and Biology (MOE and Fujian Province), Department of Chemistry, Fuzhou
University, Fuzhou350108, People’s Republic of
China
| | - Dietmar Knopp
- Department of Chemistry, Chair for Analytical
Chemistry and Water Chemistry, Institute of Hydrochemistry, Technische
Universität München, Lichtenbergstrasse 4, D-85748Garching,
Germany
| |
Collapse
|
14
|
Mahmoudi T, Naghdi T, Morales-Narváez E, Golmohammadi H. Toward smart diagnosis of pandemic infectious diseases using wastewater-based epidemiology. Trends Analyt Chem 2022; 153:116635. [PMID: 35440833 PMCID: PMC9010328 DOI: 10.1016/j.trac.2022.116635] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 03/21/2022] [Accepted: 04/07/2022] [Indexed: 12/12/2022]
Abstract
COVID-19 outbreak revealed fundamental weaknesses of current diagnostic systems, particularly in prediction and subsequently prevention of pandemic infectious diseases (PIDs). Among PIDs detection methods, wastewater-based epidemiology (WBE) has been demonstrated to be a favorable mean for estimation of community-wide health. Besides, by going beyond purely sensing usages of WBE, it can be efficiently exploited in Healthcare 4.0/5.0 for surveillance, monitoring, control, and above all prediction and prevention, thereby, resulting in smart sensing and management of potential outbreaks/epidemics/pandemics. Herein, an overview of WBE sensors for PIDs is presented. The philosophy behind the smart diagnosis of PIDs using WBE with the help of digital technologies is then discussed, as well as their characteristics to be met. Analytical techniques that are pushing the frontiers of smart sensing and have a high potential to be used in the smart diagnosis of PIDs via WBE are surveyed. In this context, we underscore key challenges ahead and provide recommendations for implementing and moving faster toward smart diagnostics.
Collapse
Affiliation(s)
- Tohid Mahmoudi
- Nanosensors Bioplatforms Laboratory, Chemistry and Chemical Engineering Research Center of Iran, 14335-186, Tehran, Iran
| | - Tina Naghdi
- Nanosensors Bioplatforms Laboratory, Chemistry and Chemical Engineering Research Center of Iran, 14335-186, Tehran, Iran
| | - Eden Morales-Narváez
- Biophotonic Nanosensors Laboratory, Centro de Investigaciones en Óptica, A. C. Loma del Bosque 115, Lomas del Campestre, 37150, León, Guanajuato, Mexico
| | - Hamed Golmohammadi
- Nanosensors Bioplatforms Laboratory, Chemistry and Chemical Engineering Research Center of Iran, 14335-186, Tehran, Iran
| |
Collapse
|
15
|
The Loan Trinh K, Ri Chae W, Yoon Lee N. Recent advances in the fabrication strategies of paper-based microfluidic devices for rapid detection of bacteria and viruses. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107548] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|