1
|
Streďanská A, Nečas D, Vrbka M, Suchánek J, Matonohová J, Toropitsyn E, Hartl M, Křupka I, Nešporová K. Understanding frictional behavior in fascia tissues through tribological modeling and material substitution. J Mech Behav Biomed Mater 2024; 155:106566. [PMID: 38729087 DOI: 10.1016/j.jmbbm.2024.106566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 04/12/2024] [Accepted: 05/03/2024] [Indexed: 05/12/2024]
Abstract
The objective of this study is to develop a reliable tribological model to enable a more thorough investigation of the frictional behavior of fascia tissues connected to non-specific lower back pain. Several models were designed and evaluated based on their coefficient of friction, using a low-frequency, low-load reciprocating motion. The study found that two technical elastomers, layered on PDMS to simulate the fascia and underlying muscle, are suitable substitutes for biological tissue in the model. The influence of tribopair geometry was also examined, and the results showed that greater conformity of contact leads to a lower COF, regardless of the material combination used. Finally, the friction properties of HA of various molecular weights and concentrations were tested.
Collapse
Affiliation(s)
- A Streďanská
- Biotribology Research Group, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69, Brno, Czech Republic.
| | - D Nečas
- Biotribology Research Group, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69, Brno, Czech Republic
| | - M Vrbka
- Biotribology Research Group, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69, Brno, Czech Republic
| | - J Suchánek
- Faculty of Medicine in Hradec Králové, Charles University, Šimkova 870, 500 03, Hradec Králové, Czech Republic
| | - J Matonohová
- Contipro a.s., Dolní Dobrouč 401, 561 02, Dolní Dobrouč, Czech Republic
| | - E Toropitsyn
- Contipro a.s., Dolní Dobrouč 401, 561 02, Dolní Dobrouč, Czech Republic
| | - M Hartl
- Biotribology Research Group, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69, Brno, Czech Republic
| | - I Křupka
- Biotribology Research Group, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69, Brno, Czech Republic
| | - K Nešporová
- Contipro a.s., Dolní Dobrouč 401, 561 02, Dolní Dobrouč, Czech Republic
| |
Collapse
|
2
|
Exploring the lubrication mechanisms of synovial fluids for joint longevity - A perspective. Colloids Surf B Biointerfaces 2021; 206:111926. [PMID: 34153619 DOI: 10.1016/j.colsurfb.2021.111926] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 05/20/2021] [Accepted: 06/14/2021] [Indexed: 01/09/2023]
Abstract
Synovial fluids are complex fluids responsible for the exceptional lubrication present in synovial joints. These fluids consist of various constituents, including hyaluronic acid, surface-active proteins (i.e., lubricin), surface-active phospholipids, as well as various other proteins such as human serum albumin and γ -globulin seric proteins, each of them playing an essential role in lubrication. Being the key to the most efficient biotribological systems, this article is intended to review the current understanding of the underlying lubrication mechanisms of the synovial fluids enables prospective usage in numerous applications, especially as a lubricant for hip and knee prosthetics in combatting osteoarthritis. Current research focuses on the determination of the role of proteins in prosthetic lubrication, optimal material combinations for prosthesis, and the effects of relevant physical variables in prosthetic lubrication. The characterization of prosthetic lubrication and wear mechanisms by synovial fluids represents a prominent challenge in tribological research, yet also an important hurdle to overcome towards optimal lubrication of articular prosthetics.
Collapse
|
3
|
Rothammer B, Marian M, Rummel F, Schroeder S, Uhler M, Kretzer JP, Tremmel S, Wartzack S. Rheological behavior of an artificial synovial fluid - influence of temperature, shear rate and pressure. J Mech Behav Biomed Mater 2020; 115:104278. [PMID: 33340776 DOI: 10.1016/j.jmbbm.2020.104278] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 10/30/2020] [Accepted: 12/12/2020] [Indexed: 02/06/2023]
Abstract
Despite the excellent clinical performance of joint replacements, wear-induced aseptic loosening is a main cause of premature implant failure. Tribological testing is usually carried out using bovine serum as an artificial synovial fluid. In order to gain new insights into the suitability to simulate human synovial fluid and provide recommendations for the conditions of tribological testing, accurate rheological measurements on the influence of temperature, shear rate and pressure on density and viscosity were performed. Thus, a temperature dependence of density and viscosity could be verified, whereas both values decreased with higher temperatures. The temperature dependency of viscosity could be approximated by an Arrhenius model. Moreover, shear-thinning characteristics could be demonstrated and fitted to a Cross model, which agreed well with investigations on human synovial fluid reported in literature. Furthermore, an anomaly of pressure dependence of viscosity was found and correlated with the behavior of water as a main constituent. At room temperature, the viscosity initially decreased to a minimum and then increased again as a function of pressure. This was no longer distinct at human body temperatures. Consequently, the present study confirms the suitability of bovine serum as a substitute synovial fluid and emphasizes the importance of realistic testing conditions in order to ensure transferability and comparability.
Collapse
Affiliation(s)
- Benedict Rothammer
- Engineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | - Max Marian
- Engineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | | | - Stefan Schroeder
- Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, Germany.
| | - Maximilian Uhler
- Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, Germany.
| | - J Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, Germany.
| | - Stephan Tremmel
- Engineering Design and CAD, University of Bayreuth, Bayreuth, Germany.
| | - Sandro Wartzack
- Engineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| |
Collapse
|
4
|
Nečas D, Sadecká K, Vrbka M, Galandáková A, Wimmer MA, Gallo J, Hartl M. The effect of albumin and γ-globulin on synovial fluid lubrication: Implication for knee joint replacements. J Mech Behav Biomed Mater 2020; 113:104117. [PMID: 33065468 DOI: 10.1016/j.jmbbm.2020.104117] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 08/31/2020] [Accepted: 09/24/2020] [Indexed: 02/07/2023]
Abstract
Total knee arthroplasty has become a routine procedure for patients suffering from joint diseases. Although the number of operations continuously increases, a limited service-life of implants represents a persisting challenge for scientists. Understanding of lubrication may help to suitably explain tribological processes on the way to replacements that become durable well into the third decade of service. The aim of the present study is to assess the formation of protein lubricating film in the knee implant. A developed knee simulator was used to observe the contact of real femoral and transparent polymer tibial component using fluorescent microscopy. The contact was lubricated by various protein solutions with attention to the behaviour of albumin and γ-globulin. In order to suitably mimic a human synovial fluid, hyaluronic acid and phospholipids were subsequently added to the solutions. Further, the change in shape and the migration of the contact zone were studied. The results showed considerable appearance differences of the contact over the swing phase of the simplified gait cycle. Regarding film formation, a strong interaction of the various molecules of synovial fluid was observed. It was found that the thickness of the lubricating layer stabilizes within around 50 s. Throughout the contact zone, protein agglomerations were present and could be clearly visualised using the applied optical technique.
Collapse
Affiliation(s)
- D Nečas
- Dept of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Czech Republic.
| | - K Sadecká
- Dept of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Czech Republic
| | - M Vrbka
- Dept of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Czech Republic
| | - A Galandáková
- Dept of Medical Chemistry and Biochemistry, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
| | - M A Wimmer
- Dept of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - J Gallo
- Dept of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, University Hospital Olomouc, Czech Republic
| | - M Hartl
- Dept of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Czech Republic
| |
Collapse
|