1
|
Poncioni S, Lippuner K, Zysset P. Advancing HR-pQCT-based homogenised FE models with smooth structured hexahedral meshes. Bone 2025; 193:117394. [PMID: 39855287 DOI: 10.1016/j.bone.2025.117394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Revised: 01/15/2025] [Accepted: 01/16/2025] [Indexed: 01/27/2025]
Abstract
Nonlinear homogenised finite element (hFE) models can accurately predict stiffness and strength of ultra-distal sections of the radius and tibia using in vivo HR-pQCT images. Recent findings showed good stiffness prediction at these distal sections but a limited ability to reproduce experimental strain localisation. The coarseness of voxel-based meshes reduces the computational effort at the cost of heavily simplifying the underlying geometry of the cortex, the gradient of material properties, and the resulting strain distribution. To overcome these limitations, we present a comprehensive approach to generating fully automated, smooth, and structured hexahedral meshes for HR-pQCT scans at the distal radius and tibia. This study used three datasets to validate the proposed hFE pipeline and its short-term repeatability: ex vivo 2nd generation HR-pQCT images of 21 human radii and 25 human tibiae, and 208 in vivo images from same-day repeated scans on 39 individuals. Results show high accuracy in predicting stiffness (tibia: R2=0.94, radius: R2=0.88) and yield force (tibia: R2=0.93, radius: R2=0.95). Mesh sensitivity analysis reveals stabilisation within a ± 3 % error margin. Dice similarity coefficients between mesh and scanned image were >0.98, and good element quality was achieved across the validation datasets (tibia: S-ICNavg=0.809, radius: S-ICNavg=0.764). Along with the improved volumetric representation of distal cortical and trabecular bone geometry and the good element quality, the new pipeline shows gains in computational performance: 11.70±1.49 min for triple-stack tibia images and 11.00±0.97 min for double-stack radius images, respectively. Generating structured meshes with consistent element-to-element correspondence facilitates seamless comparison between patient models or in longitudinal settings, providing an additional clinical information.
Collapse
Affiliation(s)
- Simone Poncioni
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland; Department of Osteoporosis, Bern University Hospital, Bern, Switzerland.
| | - Kurt Lippuner
- Department of Osteoporosis, Bern University Hospital, Bern, Switzerland
| | - Philippe Zysset
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Elenskaya N, Vindokurov I, Sadyrin E, Nikolaev A, Tashkinov M. Experimental Evaluation of the Effect of Degradation on the Mechanical Behavior and Morphometric Characteristics of Functionally Graded Polymer Scaffolds. Polymers (Basel) 2024; 16:3474. [PMID: 39771326 PMCID: PMC11728786 DOI: 10.3390/polym16243474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2024] [Revised: 12/06/2024] [Accepted: 12/10/2024] [Indexed: 01/16/2025] Open
Abstract
Bone transplantation ranks second worldwide among tissue prosthesis surgeries. Currently, one of the most promising approaches is regenerative medicine, which involves tissue engineering based on polymer scaffolds with biodegradable properties. Once implanted, scaffolds interact directly with the surrounding tissues and in a fairly aggressive environment, which causes biodegradation of the scaffold material. The aim of this work is to experimentally investigate the changes in the effective mechanical properties of polylactide scaffolds manufactured using additive technologies. The mechanism and the rate of the degradation process depend on the chosen material, contact area, microstructural features, and overall architecture of sample. To assess the influence of each of these factors, solid samples with different dimensions and layers orientation as well as prototypes of functionally graded scaffolds were studied. The research methodology includes the assessment of changes in the mechanical properties of the samples, as well as their structural characteristics. Changes in the mechanical properties were measured in compression tests. Microcomputed tomography (micro-CT) studies were conducted to evaluate changes in the microstructure of scaffold prototypes. Changes caused by surface erosion and their impact on degradation were assessed using morphometric analysis. Nonlinear changes in mechanical properties were observed for both solid samples and lattice graded scaffold prototypes depending on the duration of immersion in NaCl solution and exposure to different temperatures. At the temperature of 37 °C, the decrease in the elastic modulus of solid specimens was no more than 16%, while for the lattice scaffolds, it was only 4%. For expedited degradation during a higher temperature of 45 °C, these ratios were 47% and 16%, respectively. The decrease in compressive strength was no more than 32% for solid specimens and 17% for scaffolds. The results of this study may be useful for the development of optimal scaffolds considering the impact of the degradation process on their structural integrity.
Collapse
Affiliation(s)
- Nataliya Elenskaya
- Laboratory of Mechanics of Biocompatible Materials and Devices, Perm National Research Polytechnic University, 614990 Perm, Russia
| | - Ilia Vindokurov
- Laboratory of Mechanics of Biocompatible Materials and Devices, Perm National Research Polytechnic University, 614990 Perm, Russia
| | - Evgeniy Sadyrin
- Laboratory for Mechanics of Biomaterials, Don State Technical University, 344000 Rostov-on-Don, Russia
| | - Andrey Nikolaev
- Laboratory for Mechanics of Biomaterials, Don State Technical University, 344000 Rostov-on-Don, Russia
| | - Mikhail Tashkinov
- Laboratory of Mechanics of Biocompatible Materials and Devices, Perm National Research Polytechnic University, 614990 Perm, Russia
| |
Collapse
|
3
|
Klintström E, Klintström B, Smedby Ö, Moreno R. Automated region growing-based segmentation for trabecular bone structure in fresh-frozen human wrist specimens. BMC Med Imaging 2024; 24:101. [PMID: 38693510 PMCID: PMC11061919 DOI: 10.1186/s12880-024-01281-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 04/23/2024] [Indexed: 05/03/2024] Open
Abstract
Bone strength depends on both mineral content and bone structure. Measurements of bone microstructure on specimens can be performed by micro-CT. In vivo measurements are reliably performed by high-resolution peripheral computed tomography (HR-pQCT) using dedicated software. In previous studies from our research group, trabecular bone properties on CT data of defatted specimens from many different CT devices have been analyzed using an Automated Region Growing (ARG) algorithm-based code, showing strong correlations to micro-CT.The aim of the study was to validate the possibility of segmenting and measuring trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens. Data from micro-CT was used as reference. The hypothesis was that the ARG-based in-house built software could be used for such measurements.HR-pQCT image data at two resolutions (61 and 82 µm isotropic voxels) from 23 fresh-frozen human forearms were analyzed. Correlations to micro-CT were strong, varying from 0.72 to 0.99 for all parameters except trabecular termini and nodes. The bone volume fraction had correlations varying from 0.95 to 0.98 but was overestimated compared to micro-CT, especially at the lower resolution. Trabecular separation and spacing were the most stable parameters with correlations at 0.80-0.97 and mean values in the same range as micro-CT.Results from this in vitro study show that an ARG-based software could be used for segmenting and measuring 3D trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens using micro-CT data as reference. Over-and underestimation of several of the bone structure parameters must however be taken into account.
Collapse
Affiliation(s)
- Eva Klintström
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, SE-58185, Sweden.
- Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, SE-58185, Sweden.
| | - Benjamin Klintström
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, Huddinge, SE-14157, Sweden
| | - Örjan Smedby
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, Huddinge, SE-14157, Sweden
| | - Rodrigo Moreno
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, Huddinge, SE-14157, Sweden
| |
Collapse
|
4
|
Bartosik M, Simon A, Strahl A, Oheim R, Amling M, Schmidt FN. Comparison of Motion Grading in 1,000 Patients by First- and Second-Generation HR-pQCT: A Propensity Score Matched Cohort Study. Calcif Tissue Int 2023; 113:597-608. [PMID: 37880520 PMCID: PMC10673987 DOI: 10.1007/s00223-023-01143-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 09/18/2023] [Indexed: 10/27/2023]
Abstract
In-vivo bone microstructure measured by high-resolution peripheral quantitative computed tomography (HR-pQCT) is gaining importance in research and clinical practice. Second-generation HR-pQCT (XCT2) shows improved image quality and shorter measurement duration compared to the first generation (XCT1). Predicting and understanding the occurrence of motion artifacts is crucial for clinical practice. We retrospectively analyzed data from HR-pQCT measurements at the distal radius and tibia of 1,000 patients (aged 20 to 89) evenly distributed between both generations of HR-pQCT. Motion artifacts were graded between 1 (no motion) and 5 (severe motion), with grades greater 3 considered unusable. Additionally, baseline characteristics and patients' muscle performance and balance were measured. Various group comparisons between the two generations of HR-pQCT and regression analyses between patient characteristics and motion grading were performed. The study groups of XCT1 and XCT2 did not differ by age (XCT1: 64.9 vs. XCT2: 63.8 years, p = 0.136), sex (both 74.5% females, p > 0.999), or BMI (both 24.2 kg/m2, p = 0.911) after propensity score matching. XCT2 scans exhibited significantly lower motion grading in both extremities compared to XCT1 (Radius: p < 0.001; Tibia: p = 0.002). In XCT2 motion-corrupted scans were more than halved at the radius (XCT1: 35.3% vs. XCT2: 15.5%, p < 0.001), and at the tibia the frequency of best image quality scans was increased (XCT1: 50.2% vs. XCT2: 63.7%, p < 0.001). The strongest independent predictor for motion-corrupted images is the occurrence of high motion grading at the other scanning site during the same consultation. The association between high motion grading in one scan and a corresponding high motion grading in another scan within the same session suggests a non-resting patient. Additionally, aged, female, and patients with smaller stature tend towards higher motion grading, requiring special attention to a correct extremity fixation.
Collapse
Affiliation(s)
- Mikolaj Bartosik
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Alexander Simon
- Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - André Strahl
- Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Ralf Oheim
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael Amling
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Felix N Schmidt
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| |
Collapse
|
5
|
Kochetkova T, Groetsch A, Indermaur M, Peruzzi C, Remund S, Neuenschwander B, Bellon B, Michler J, Zysset P, Schwiedrzik J. Assessing minipig compact jawbone quality at the microscale. J Mech Behav Biomed Mater 2022; 134:105405. [DOI: 10.1016/j.jmbbm.2022.105405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 07/21/2022] [Accepted: 07/26/2022] [Indexed: 10/16/2022]
|
6
|
Unified validation of a refined second-generation HR-pQCT based homogenized finite element method to predict strength of the distal segments in radius and tibia. J Mech Behav Biomed Mater 2022; 131:105235. [DOI: 10.1016/j.jmbbm.2022.105235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 02/28/2022] [Accepted: 04/10/2022] [Indexed: 11/22/2022]
|
7
|
Determination of anisotropic elastic parameters from morphological parameters of cancellous bone for osteoporotic lumbar spine. Med Biol Eng Comput 2021; 60:263-278. [PMID: 34843037 PMCID: PMC8724118 DOI: 10.1007/s11517-021-02465-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 10/25/2021] [Indexed: 12/03/2022]
Abstract
In biomechanics, large finite element models with macroscopic representation of several bones or joints are necessary to analyze implant failure mechanisms. In order to handle large simulation models of human bone, it is crucial to homogenize the trabecular structure regarding the mechanical behavior without losing information about the realistic material properties. Accordingly, morphology and fabric measurements of 60 vertebral cancellous bone samples from three osteoporotic lumbar spines were performed on the basis of X-ray microtomography (μCT) images to determine anisotropic elastic parameters as a function of bone density in the area of pedicle screw anchorage. The fabric tensor was mapped in cubic bone volumes by a 3D mean-intercept-length method. Fabric measurements resulted in a high degree of anisotropy (DA = 0.554). For the Young’s and shear moduli as a function of bone volume fraction (BV/TV, bone volume/total volume), an individually fit function was determined and high correlations were found (97.3 ≤ R2 ≤ 99.1,p < 0.005). The results suggest that the mathematical formulation for the relationship between anisotropic elastic constants and BV/TV is applicable to current μCT data of cancellous bone in the osteoporotic lumbar spine. In combination with the obtained results and findings, the developed routine allows determination of elastic constants of osteoporotic lumbar spine. Based on this, the elastic constants determined using homogenization theory can enable efficient investigation of human bone using finite element analysis (FEA). Cancellous Bone with Fabric Tensor Ellipsoid representing anisotropy and principal axis (colored coordinate system) of given trabecular structure ![]()
Collapse
|
8
|
Walle M, Marques FC, Ohs N, Blauth M, Müller R, Collins CJ. Bone Mechanoregulation Allows Subject-Specific Load Estimation Based on Time-Lapsed Micro-CT and HR-pQCT in Vivo. Front Bioeng Biotechnol 2021; 9:677985. [PMID: 34249883 PMCID: PMC8267803 DOI: 10.3389/fbioe.2021.677985] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 05/17/2021] [Indexed: 11/20/2022] Open
Abstract
Patients at high risk of fracture due to metabolic diseases frequently undergo long-term antiresorptive therapy. However, in some patients, treatment is unsuccessful in preventing fractures or causes severe adverse health outcomes. Understanding load-driven bone remodelling, i.e., mechanoregulation, is critical to understand which patients are at risk for progressive bone degeneration and may enable better patient selection or adaptive therapeutic intervention strategies. Bone microarchitecture assessment using high-resolution peripheral quantitative computed tomography (HR-pQCT) combined with computed mechanical loads has successfully been used to investigate bone mechanoregulation at the trabecular level. To obtain the required mechanical loads that induce local variances in mechanical strain and cause bone remodelling, estimation of physiological loading is essential. Current models homogenise strain patterns throughout the bone to estimate load distribution in vivo, assuming that the bone structure is in biomechanical homoeostasis. Yet, this assumption may be flawed for investigating alterations in bone mechanoregulation. By further utilising available spatiotemporal information of time-lapsed bone imaging studies, we developed a mechanoregulation-based load estimation (MR) algorithm. MR calculates organ-scale loads by scaling and superimposing a set of predefined independent unit loads to optimise measured bone formation in high-, quiescence in medium-, and resorption in low-strain regions. We benchmarked our algorithm against a previously published load history (LH) algorithm using synthetic data, micro-CT images of murine vertebrae under defined experimental in vivo loadings, and HR-pQCT images from seven patients. Our algorithm consistently outperformed LH in all three datasets. In silico-generated time evolutions of distal radius geometries (n = 5) indicated significantly higher sensitivity, specificity, and accuracy for MR than LH (p < 0.01). This increased performance led to substantially better discrimination between physiological and extra-physiological loading in mice (n = 8). Moreover, a significantly (p < 0.01) higher association between remodelling events and computed local mechanical signals was found using MR [correct classification rate (CCR) = 0.42] than LH (CCR = 0.38) to estimate human distal radius loading. Future applications of MR may enable clinicians to link subtle changes in bone strength to changes in day-to-day loading, identifying weak spots in the bone microstructure for local intervention and personalised treatment approaches.
Collapse
Affiliation(s)
- Matthias Walle
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | | | - Nicholas Ohs
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Michael Blauth
- Department for Trauma Surgery, Innsbruck University Hospital, Innsbruck, Austria
| | - Ralph Müller
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | | |
Collapse
|
9
|
Ohs N, Collins CJ, Atkins PR. Validation of HR-pQCT against micro-CT for morphometric and biomechanical analyses: A review. Bone Rep 2020; 13:100711. [PMID: 33392364 PMCID: PMC7772687 DOI: 10.1016/j.bonr.2020.100711] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/29/2020] [Accepted: 08/19/2020] [Indexed: 12/26/2022] Open
Abstract
High-resolution peripheral quantitative computed-tomography (HR-pQCT) has the potential to become a powerful clinical assessment and diagnostic tool. Given the recent improvements in image resolution, from 82 to 61 μm, this technology may be used to accurately quantify in vivo bone microarchitecture, a key biomarker of degenerative bone diseases. However, computational methods to assess bone microarchitecture were developed for micro computed tomography (micro-CT), a higher-resolution technology only available for ex vivo studies, and validation of these computational analysis techniques against the gold-standard micro-CT has been inconsistent and incomplete. Herein, we review methods for segmentation of bone compartments and microstructure, quantification of bone morphology, and estimation of mechanical strength using finite-element analysis, highlighting the need throughout for improved standardization across the field. Studies have relied on homogenous datasets for validation, which does not allow for robust comparisons between methods. Consequently, the adaptation and validation of novel segmentation approaches has been slow to non-existent, with most studies still using the manufacturer's segmentation for morphometric analysis despite the existence of better performing alternative approaches. The promising accuracy of HR-pQCT for capturing morphometric indices is overshadowed by considerable variability in outcomes between studies. For finite element analysis (FEA) methods, the use of disparate material models and FEA tools has led to a fragmented ability to assess mechanical bone strength with HR-pQCT. Further, the scarcity of studies comparing 62 μm HR-pQCT to the gold standard micro-CT leaves the validation of this imaging modality incomplete. This review revealed that without standardization, the capabilities of HR-pQCT cannot be adequately assessed. The need for a public, extendable, heterogeneous dataset of HR-pQCT and corresponding gold-standard micro-CT images, which would allow HR-pQCT users to benchmark existing and novel methods and select optimal methods depending on the scientific question and data at hand, is now evident. With more recent advancements in HR-pQCT, the community must learn from its past and provide properly validated technologies to ensure that HR-pQCT can truly provide value in patient diagnosis and care.
Collapse
Affiliation(s)
- Nicholas Ohs
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | | | - Penny R. Atkins
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
- Department of Osteoporosis, Inselspital, Bern, Switzerland
| |
Collapse
|
10
|
Steiner L, Synek A, Pahr DH. Comparison of different microCT-based morphology assessment tools using human trabecular bone. Bone Rep 2020; 12:100261. [PMID: 32455148 PMCID: PMC7235944 DOI: 10.1016/j.bonr.2020.100261] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 03/19/2020] [Accepted: 03/23/2020] [Indexed: 12/12/2022] Open
Abstract
MicroCT-based morphological parameters are often used to quantify the structural properties of trabecular bone. Various software tools are available for calculating these parameters. Studies that examine the comparability of their results are rare. Four different software tools were used to analyse a set of 701 microCT images from human trabecular bone samples. Bone volume to total volume (BV/TV), bone surface (BS), trabecular thickness (Tb. Th.) and degree of anisotropy (DA) were evaluated. BV/TV shows very low difference (-0.18 ± 0.15%). The difference in BS could be reduced below 5% if artificial cut surfaces are not included. Tb. Th. and Tb. Sp. show differences of maximal -12% although the same theoretical background is used. DA is most critical with differences from 4.75 ± 3.70% (medtool vs. Scanco), over -38.61 ± 13.15% (BoneJ vs. Scanco), up to 80.52 ± 50.04% (medtool vs. BoneJ). Quantitative results should be considered with caution, especially when comparing different studies. Introducing standardization procedures and the disclosure of underlying algorithms and their respective implementations could improve this issue.
Collapse
Affiliation(s)
- Lukas Steiner
- Institute for Lightweight Design and Structural Biomechanics, TU-Wien, Vienna, Austria
| | - Alexander Synek
- Institute for Lightweight Design and Structural Biomechanics, TU-Wien, Vienna, Austria
| | - Dieter H Pahr
- Institute for Lightweight Design and Structural Biomechanics, TU-Wien, Vienna, Austria.,Department of Anatomy and Biomechanics, Karl Landsteiner University of Health Sciences, Krems, Austria
| |
Collapse
|
11
|
Mirzaali MJ, Libonati F, Ferrario D, Rinaudo L, Messina C, Ulivieri FM, Cesana BM, Strano M, Vergani L. Determinants of bone damage: An ex-vivo study on porcine vertebrae. PLoS One 2018; 13:e0202210. [PMID: 30114229 PMCID: PMC6095531 DOI: 10.1371/journal.pone.0202210] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Accepted: 07/29/2018] [Indexed: 02/07/2023] Open
Abstract
Bone's resistance to fracture depends on several factors, such as bone mass, microarchitecture, and tissue material properties. The clinical assessment of bone strength is generally performed by Dual-X Ray Photon Absorptiometry (DXA), measuring bone mineral density (BMD) and trabecular bone score (TBS). Although it is considered the major predictor of bone strength, BMD only accounts for about 70% of fragility fractures, while the remaining 30% could be described by bone "quality" impairment parameters, mainly related to tissue microarchitecture. The assessment of bone microarchitecture generally requires more invasive techniques, which are not applicable in routine clinical practice, or X-Ray based imaging techniques, requiring a longer post-processing. Another important aspect is the presence of local damage in the bony tissue that may also affect the prediction of bone strength and fracture risk. To provide a more comprehensive analysis of bone quality and quantity, and to assess the effect of damage, here we adopt a framework that includes clinical, morphological, and mechanical analyses, carried out by means of DXA, μCT and mechanical compressive testing, respectively. This study has been carried out on trabecular bones, taken from porcine trabecular vertebrae, for the similarity with human lumbar spine. This study confirms that no single method can provide a complete characterization of bone tissue, and the combination of complementary characterization techniques is required for an accurate and exhaustive description of bone status. BMD and TBS have shown to be complementary parameters to assess bone strength, the former assessing the bone quantity and resistance to damage, and the latter the bone quality and the presence of damage accumulation without being able to predict the risk of fracture.
Collapse
Affiliation(s)
| | - Flavia Libonati
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Davide Ferrario
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Luca Rinaudo
- TECHNOLOGIC S.r.l. Hologic Italia, Torino, Italy
| | - Carmelo Messina
- Istituto Ortopedico Galeazzi IRCCS, Radiodiagnostic Unit, Milan, Italy
| | - Fabio M. Ulivieri
- Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Nuclear Medicine-Bone Metabolic Unit, Milan, Italy
| | - Bruno M. Cesana
- Department of Clinical Sciences and Community Health, Unit of Medical Statistics, Biometry and Bioinformatics "Giulio A. Maccacaro", Faculty of Medicine and Surgery, University of Milan, Milan, Italy
| | - Matteo Strano
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Laura Vergani
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
12
|
Wili P, Maquer G, Panyasantisuk J, Zysset PK. Estimation of the effective yield properties of human trabecular bone using nonlinear micro-finite element analyses. Biomech Model Mechanobiol 2017. [DOI: 10.1007/s10237-017-0928-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
13
|
Hosseini HS, Dünki A, Fabech J, Stauber M, Vilayphiou N, Pahr D, Pretterklieber M, Wandel J, Rietbergen BV, Zysset PK. Fast estimation of Colles' fracture load of the distal section of the radius by homogenized finite element analysis based on HR-pQCT. Bone 2017; 97:65-75. [PMID: 28069517 DOI: 10.1016/j.bone.2017.01.003] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 01/02/2017] [Accepted: 01/05/2017] [Indexed: 11/29/2022]
Abstract
Fractures of the distal section of the radius (Colles' fractures) occur earlier in life than other osteoporotic fractures. Therefore, they can be interpreted as a warning signal for later, more deleterious fractures of vertebral bodies or the femoral neck. In the past decade, the advent of HR-pQCT allowed a detailed architectural analysis of the distal radius and an automated but time-consuming estimation of its strength with linear micro-finite element (μFE) analysis. Recently, a second generation of HR-pQCT scanner (XtremeCT II, SCANCO Medical, Switzerland) with a resolution beyond 61 μm became available for even more refined biomechanical investigations in vivo. This raises the question how biomechanical outcome variables compare between the original (LR) and the new (HR) scanner resolution. Accordingly, the aim of this work was to validate experimentally a patient-specific homogenized finite element (hFE) analysis of the distal section of the human radius for the fast prediction of Colles' fracture load based on the last generation HR-pQCT. Fourteen pairs of fresh frozen forearms (mean age = 77.5±9) were scanned intact using the high (61 μm) and the low (82 μm) resolution protocols that correspond to the new and original HR-pQCT systems. From each forearm, the 20mm most distal section of the radius were dissected out, scanned with μCT at 16.4 μm and tested experimentally under compression up to failure for assessment of stiffness and ultimate load. Linear and nonlinear hFE models together with linear micro finite element (μFE) models were then generated based on the μCT and HR-pQCT reconstructions to predict the aforementioned mechanical properties of 24 sections. Precision errors of the short term reproducibility of the FE analyses were measured based on the repeated scans of 12 sections. The calculated failure loads correlated strongly with those measured in the experiments: accounting for donor as a random factor, the nonlinear hFE provided a marginal coefficient of determination (Rm2) of 0.957 for the high resolution (HR) and 0.948 for the low resolution (LR) protocols, the linear hFE with Rm2 of 0.957 for the HR and 0.947 for the LR protocols. Linear μFE predictions of the ultimate load were similar with an Rm2 of 0.950 for the HR and 0.954 for the LR protocols, respectively. Nonlinear hFE strength computation led to precision errors of 2.2 and 2.3% which were higher than the ones calculated based on the linear hFE (1.6 and 1.9%) and linear μFE (1.2 and 1.6%) for the HR and LR protocols respectively. Computation of the fracture load with nonlinear hFE demanded in average 6h of CPU time which was 3 times faster than with linear μFE, while computation with linear hFE took only a few minutes. This study delivers an extensive experimental and numerical validation for the application of an accurate and fast hFE diagnostic tool to help in identifying individuals who may be at risk of an osteoporotic wrist fracture and to follow up pharmacological and other treatments in such patients.
Collapse
Affiliation(s)
- Hadi S Hosseini
- Institute for Surgical Technology and Biomechanics, University of Bern, Bern, Switzerland
| | - Andreas Dünki
- Institute for Surgical Technology and Biomechanics, University of Bern, Bern, Switzerland
| | - Jonas Fabech
- Institute for Surgical Technology and Biomechanics, University of Bern, Bern, Switzerland
| | | | | | - Dieter Pahr
- Institute of Lightweight Design and Structural Biomechanics, Vienna University of Technology, Vienna, Austria
| | | | - Jasmin Wandel
- Institute for Risk and Extremes, Bern University of Applied Sciences, Burgdorf, Switzerland
| | - Bert van Rietbergen
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Philippe K Zysset
- Institute for Surgical Technology and Biomechanics, University of Bern, Bern, Switzerland.
| |
Collapse
|